Home

CWR-264XC User Manual.book

image

Contents

1. Bit Format N 8 1 Printer Port Quantity 1 parallel for use with inkjet and laserjet printers Capacities continued Liquid Crystal Display Characters 80 total on 4 lines Character Set A Z upper and lower case 0 9 various symbols Viewing Area 2 8 by 8 Front Panel Keypad Quantity 20 keys Keys 0 9 Browse Alpha Setup Esc Enter Print left right up down Virtual Inputs Quantity 32 user assigned Definitions Any logical association shared by 1 to 4 variables i e Digital Analog Timer or Virtual Inputs Assigned by defining the state of the Virtual Input for each combi nation of variable states Reporting Creates standard Event Record Relays can be controlled by each Virtual Input Modem can be set up to dial out Event Record Timer Inputs Quantity 999 user assigned Programming Any Digital Analog Virtual or Timer Input can be assigned as the trigger source Any Digital Analog or Virtual Input can be assigned as the terminating source On or Off events can be assigned as the trigger or terminating source MICRO AIDE CWR 264XC USER MANUAL Timer Inputs continued Limit Values Separate high and low limits per assigned Timer Input in multiples of 1 seconds Range 0 0 to 999 9 seconds Reporting Measured Time is reported in each Timer Input Event Record Violation of Limit Values are also reported Train Speed Monitor Quantity 16 total separa
2. APPENDIX A A TECHNICAL DATA CWR 264P Specifications Physical Size Length 19 0 Height 7 8 10 5 of rack space Depth 3 2 Weight 4lb Environmental Storage Temperature 50 C to 85 C Humidity 0 to 95 non condensing Operating Temperature 40 C to 72 C Humidity 0 to 95 non condensing Mounting Standard mounts in 19 rack Optional 23 rack mounting brackets available Construction Chassis Fully enclosed anodized aluminum Externally accessible keypad LEDs and connectors Electrical All components mounted on conformal coated internal PCBs Power Voltage Range 10 to 36Vdc Consumption Typical 6W Maximum 7W Isolation Power Minimum 3800Vdc from B and N terminals to chassis Internal Modem Designed to meet FCC part 68 standards Ethernet Port Minimum 3800Vdc to any terminal Capacities CWR 264S 1 to 16 Secondary Units Programmable Inputs Virtual 32 user assigned Timer 999 user assigned Outputs Relays 4 dual form C rated for 2A at 24Vdc or 1A at 125Vac maximum switching capacity of 125VA or 60W service life 1 million electrical typical Event Storage Standard 1 816 045 records Memory Full 129th day over writes first day newest data over writes oldest data Ethernet Port Quantity 1 Type 10 100 Base T RS 232 Port Quantity 2 for use with a PC Emulation ANSI Baud Rates 300 600 1200 2400 4800 9600 19 200 38 400 57 600 115 200
3. Environmental Capacities Storage Inputs Digital 256 all opto isolated Analog 8 total 4 can measure current Event Storage Standard 100 000 Event Record buffer used to save records before polling by Primary Unit Temperature 50 C to 85 C Humidity 0 to 95 non condensing Operating Temperature 40 C to 72 C Humidity 0 to 95 non condensing Type non volatile flash memory Mounting Ethernet Port Standard mounts in 19 rack Quantity 1 Optional 23 rack mounting Type 10 100 Base T brackets available RS 232 Port Quantity 1 for use with a PC Construction Usage serves as a diagnostic Chassis port Fully enclosed anodized Emulation ANSI aluminum Baud Rates 300 600 1200 Externally accessible LED and 2400 4800 9600 19 200 connectors 38 400 57 600 115 200 Electrical Bit Format N 8 1 All components mounted on conformal coated internal PCBs Inputs Input Impedance Digital minimum 10KOhms opto isolated Analog minimum 10MOhms Range Digital Input On 5 to 40Vdc Digital Input Off 0 to 2Vdc Analog DC Voltage 3 scales 25 5 51 1 255 Analog AC Voltage 2 scales 25 5 255 Analog Current 2 scales Power Voltage Range 10 to 36Vdc Consumption Typical 6W Maximum 7W Isolation Power Minimum 3800 Vdc from B and N terminals to chassis and inputs Digital Inputs optional 25 5Adc 25 5Aac Minimum 3800Vdc to any Event Validation Times terminal Digital
4. only access to Event Record and Setup Data base viewing only limit 8 characters Entire Setup Database is under control of the Primary Unit Usage applies only to Terminal Port The following cable is included with every CWR 264XC Ethernet Port Type 10 100 Base T Usage normally connected to LAN via CAT 5 cable to Ethernet Switch Speed 100Mbps Protocol TCP IP Telnet LED Indicators Green link established Yellow data activity MICRO AIDE reserves the right to make changes at its sole discretion to any specifications listed herein Terminal Port of CWR Comm Port of PC Configured as DCE DE 9 Female Pin Signal Pin DCD 4 RD D 1 1 2 2 i DTR ri 5 Gnd 5 6 DSR 6 TA 7 8 8 9 9 ge RIS GS y RI o Shield is not attached Figure 13 Terminal Port Cable Wiring Diagram Configured as DTE DE 9 Female
5. 01 to 327 67 seconds compatible with fixed rate flashing circuits Analog fast and slow filter settings Analog Inputs Minimum 3800Vdc to any terminal Analog Input Accuracy Typical Vdc 1 full scale Typical Vac 1 5 full scale Typical Current 2 full scale Analog Limit Values Voltage Separate high and low limits in multiples of 1V or 1V Current Separate high and low limits in multiples of 1A Internal Temperature Separate high and low limits 67 F to 257 F Memory Type Non volatile Event Records and Setup Database are stored in flash memory chips Storage Longevity Infinite with power off Rated for 1 million write operations Connectors Digital and Analog Inputs Detachable screw down 6 or 8 terminals each 12 to 22AWG Terminal Port DE 9 male configured as DCE Power Detachable screw down 4 posi tion 12 to 22AWG Dual B and N terminals Ethernet Port RJ 45 female Current Sensor DE 9 female used with CWR CS Indicators LED power green Internal Clock Accuracy Typical 1 minute per month 20ppm Sync Primary Unit synchronizes each Secondary Unit cloc every 10 seconds MICRO AIDE CWR 264XC USER MANUAL Internal Clock continued Password Protection Resolution Event Records are time stamped to nearest 01 seconds Operation Full calendar auto adjusted for leap year Non volatile with power off Y2K compliant Terminal Port Cable Type Restricted
6. rds are time stamped to nearest 01 seconds Operation Full calendar auto adjusted for leap year Non volatile with power off Y2K compliant Password Protection Administrative Level Access to all functions limit 8 characters Restricted Level Access to Event Record and Setup Database viewing only limit 8 characters Passcode Protects against alterations to Setup Database via front panel limit 8 digits Internal Modem Type V 34 33 600 Baud data compression and error correction Usage Remote access via auto answer operation Allows dial out alarm reporting of Virtual Input records Compliance Designed to meet FCC part 68 standards Dial out Alarms Calling Method Primary and secondary dial numbers multiple attempts Tone or pulse dialing Data Issues Event Record for enabled Virtual Inputs Ethernet Port Type 10 100 Base T Usage normally connected to LAN via CAT 5 cable to Ethernet Switch Speed 100Mbps Protocol TCP IP Telnet LED Indicators Green link established Yellow data activity MICRO AIDE reserves the right to make changes at its sole discretion to any specifications listed herein APPENDIX A TECHNICAL DATA CWR 264S Specifications Physical Isolation continued Size Input to Adjacent Input Length 19 0 Digital minimum 3800Vdc Height 7 8 10 5 of rack space Analog minimum 3200Vdc Depth 3 8 Ethernet Port Weight Minimum 3800Vdc to any 7 b terminal
7. tely programmable Operation Reports excessive train speed Logs standard Event Record Sensors are wired to 2 spare Digital Inputs Limit Values 5 to 180mph Distance between Sensors 50 to 5280 Memory Type Non volatile Event Records and Setup Database are stored in flash memory chips Storage Longevity Infinite with power off Rated for 1 million write operations Connectors Terminal Ports 2 DE 9 male configured as DCE Printer Port DB 25 female standard parallel printer configuration Power Detachable screw down 4 posi tion 12 to 22AWG Dual B and N terminals Connectors continued Alarm Relays Detachable screw down 12 position 12 to 22AWG 4 sets of N O N C and common Telephone Line 2 RJ 11 female wired in parallel Ethernet Port RJ 45 female Controls Keypad 20 keys located on front panel LCD Contrast Adjust Single turn potentiometer located on front panel Indicators LCD Panel Includes LED back lighting for enhanced visibility Displays numerous command menus for configuring the recorder and retrieving data LEDs 3 Power green Terminal green flashes with send rcv data Modem green flashes with send rcv data and ring in Internal Clock Accuracy Typical 1 minute per month 20ppm Sync spare Digital Input used to synchronize real time clock of Primary Unit Synchronizes clock of Secondary Unit s every 10 seconds Resolution Event Reco