Complete Installation and Operating Instructions for ADAEZ Trash

image

Contents

1. a F LAdLNO NIYN XAlddNS YAMOd 384209 Dds Move LNO WOO NI Pte ssa00y YMd OdArZ SIS GND pz pisul ddo 1ooq ZMS plsinO LMS ar awe npolN soeLeju ALasvS AWS WOO qa J NYYO AONVYO 4007 ON WOO ON YOSNAS 31S onims 999 910002 Rev B 11 of 14 2013 ADA EZ ALL RIGHTS RESERVED 9 PROGRAMMING INSTRUCTIONS 9 1 Programming the Operator 9 1 1 Refer to Figure 5 and at the base of the controller PRESS and HOLD the SELECT and ENTER pushbuttons for three seconds The following shall occur e The operator shall enter program mode e LEDs DS8 through DS11 shall flash green briefly e The CLS close position LED shall illuminate red and remain lit NOTE When performing the auto tune process for the first time LED indications for CLS OP and AUTO SETUP will be RED indicating that no values have been previously stored for those parameters When programming the operator a second time the LEDs will illuminate green 9 1 2 With the door in the closed position PRESS and RELEASE the ENTER pushbutton The following shall occur e The CLS position LED shall flash green briefly e The OP open position LED shall illuminate next NOTE
2. Installation and Operating Instructions ez ADA EZ Trash Room Door WIRE FREE DOOR OPENER ADA EZ Trash Room Door Installation and Operating Instructions 910002 Rev B To obtain the latest manual and template revisions or to view installation and programming videos go to www ADAEZ com For technical support call 877 232 3987 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 1 of 14 PURPOSE 1 1 1 2 Discussion This manual provides system description installation instructions troubleshooting recommendations and a replacement parts list for the ADA EZ Trash Room Door TRD product When properly installed and programmed the ADA EZ TRD will put the door in the HOLD OPEN function when the DK12 presence sensor detects an occupant in the sensing area after an automatic open cycle The DK12 presence sensor looks at the sensing area makes a map of the area and sends a signal to the operator if the sensing area has changed The sensor will re learn the map of the sensing area after an adjustable period of time default is one minute Adjustments to the sensor can be made using the OPTIONAL wireless remote p n 1027 R An electric lock is NOT included in the ADA EZ TRD kit Applicability This manual is applicable to the ADA EZ TRD series door operator 2 PREREQUISITES 2 1 2 2 2 3 2 4 25 The ADA EZ TRD door operator must be installed according to the ADA EZ P
3. 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 7 of 14 7 WIRING THE DOOR OPERATOR Figure 5 Route Wires Through Door Cord 24VDC GROUND sIGNAL RED GREEN BLUE WIRE WIRE WIRE 7 1 7 2 7 3 7 4 75 ADA EZ CHARGER CONNECTION ROUTE WIRE THROUGH ROUTE WIRE END LINKS 3 THROUGH 4 DOOR CORD CCE TIES Refer to Figure 5 and route the power and signal wires from 24VDC power supply to the door operator under the wire channel and wire exit hole on the door cord mounting bracket Using the mounting screws provided secure the door cord mounting bracket behind the battery pack location Refer to Figure 5 and route the power and signal wires through the armored door cord to the interface module Apply the door cord mounting bracket cover over the mounting bracket to secure the door cord in place Secure the other door cord mounting bracket to the adjacent wall or frame using the mounting screw provided 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 8 of 14 Figure 6 Door Cord Mounting REMOVE COVER PLUG IN CONNECTOR REPLACE COVER A 5 NA A Se eee MMM My MOUNT DOOR CORD WITH END LINKS LED LIGHTS STEADY GREEN WHEN 24VDC POWER IS APPLIED ENSURE SWITCH IS SET TO ON 8 WIRING THE POWER SUPPLY 8 1 Refer to Figure 6 for wire connection location 8 2 Refer to Figure 7 Wiring Diagram for the wiring schematic
4. Wait until the OP open position LED illuminates to move the door to the open position Failure to wait to move the door may cause the door to auto tune in the wrong direction 913 With the door in the fully open position PRESS and RELEASE the ENTER pushbutton OR PRESS and RELEASE the pushbutton actuator The following shall occur e The OP position LED shall flash green briefly e The AUTO SETUP LED shall illuminate red next NOTE If the ENTER button is not accessible when the door is in the OPEN position the Activate Pushbuttons may be used to set instead of pressing ENTER 9 1 4 RETURN the door to the fully closed position and PRESS and RELEASE the ENTER pushbutton The following shall occur e The door shall open partially and then close e The AUTO SETUP led shall illuminate green 9 1 5 To exit the Auto Tune mode PERFORM the following a PRESS and HOLD the ENTER pushbutton for three seconds The following shall occur e The AUTO SETUP led shall go out e Auto Tune shall be complete The door shall be tuned 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 12 of 14 9 1 6 To RESET the controller PERFORM the following e While pressing and holding the ENTER pushbutton on the controller PRESS and RELEASE the RESET pushbutton Resetting the controller does not reset the Interface Module linking to the operator controller The
5. CAUTION Do not connect the Power Supply to line voltage until all low voltage wiring is complete The jumper PS 1 may be removed to turn off the 24VDC power supply 8 3 Connect the ACTIVATION BUTTON S to the terminal labeled ACT BUTTON 8 4 Connect the ELECTRIC LOCK to the terminal labeled LOCK 8 5 Connect the DOOR OPERATOR to terminal labeled OPERATOR using the supplied 3 conductor wire 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 9 of 14 8 5 1 Connect the RED wire to the terminal labeled 8 5 2 Connect the GREEN wire to the terminal labeled 8 5 3 Connect the BLUE wire to the terminal labeled SIG Figure 7 Wiring the Power Supply Terminal Block CONNECT PUSHBUTTON CONNECT THE CONNECT 3 WIRES ACTUATOR HERE ELECTRIC LOCK FROM DOOR HERE OPERATOR HERE 8 6 Connect the POWER SUPPLY to 115VAC line voltage 8 6 1 Ensure jumper PS 1 is in place and verify a The LED located on the door operator POWER PACK illuminates STEADY GREEN If the LED does not light REVERSE polarity is being supplied to the door operator and the connection must be corrected 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 10 of 14 w G E 9 N On lt z Q gt Z o _ G31S3NNOO LON SI T3NVd Jus sl 3OV1d NI 38 LSNW Y3dWNr Josuas Aouednoo9 OGAre YMd
6. RESET 2 PRESS and RELEASE LEARN unitil LEDs DS8 DS11 slowly Flash GREEN 3 Press and release the ACTIVATION PUSHBUTTONS LED DS7 quickly flashes GREEN and goes out The Operator begins to close but re opens during a close cycle OR The Operator begins to open when the DK12 sensor LED lights Verify that the Door Operator is programmed for Occupancy sensor input 1 On the Operator Control board PRESS and HOLD SELECT for 10 seconds 2 Rotate the Potentiometer until DS10 lights GREEN PRESS and RELEASE the ENTER button on the control board to store the setting PRESS and HOLD the ENTER button for 3 seconds to exit programming mode The Operator begins to open before the Electric Lock is unlocked Refer to the section titled LOCK DELAY and increase the lock delay time Problems with the DK12 sensor e Refer to the DK12 USER GUIDE troubleshooting section 2013 ADA EZ ALL RIGHTS RESERVED 910002 Rev B 14 of 14
7. no time delay Switch 1 set to on 1 2 second delay Switch 2 set to on 1 second delay Switch 3 set to on 2 second delay LOCK Provides a 24VDC 1A maximum power output to activate an electric lock ACT Button Provides and activate signal which will unlock the door and cause the operator to enter an automatic open cycle OPERATOR Provides a 24VDC power output and signal to the ADA EZ Door Operator FIRE PANEL When the FIRE PANEL contact is open the interface module will cause the operator to close the door and ignore all activation signals If the FIRE PANEL option is not desired the jumper must be left in place 6 WIRING THE DK12 OCCUPANCY SENSOR 6 1 The DK 12 sensor comes mounted to the power supply box and is pre wired at the factory If it is necessary to relocate the sensor it must be wired as follows 6 1 1 6 1 2 6 1 4 Connect the RED wire to position 1 PWR on the DK12 Terminal Block Connect the RED wire to the terminal block location labeled SENSOR Connect the BLACK wire to position 2 PWR on the DK12 Terminal Block Connect the BLACK wire to the terminal block location labeled SENSOR Connect the GREEN wire to position 3 COM on the DK12 Terminal Block Connect the GREEN wire to the terminal block location labeled SENSOR GRN Connect the WHITE wire to position 4 NO on the DK12 Terminal Block Connect the WHITE wire to the terminal block position labeled SENSOR WHT
8. GE g 32 8 3 20 Bara 32 20 4 6 6 6 32 DO NOT USE DO NOT USE Figure 3 Sensor Mounting Angle k X N lt Remove End Cap Loosen Setscrew Remove Sensor from Bracket Z 20 deg Standard Angle 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 5 of 14 5 1 3 The sensor may be relocated from the front of the power supply cabinet if necessary Replace the two mounting screws into the mounting holes after removing the sensor from the front cover 5 1 4 The sensor area can be adjusted Refer to the included DK 12 user s manual for sensor adjustment 5 2 Features and Functions 5 2 1 The Power Supply is pre wired at the factory The Electric Lock Activation Buttons and 3 conductor wire that provides power and signal to the door operator must be connected as part of the installation 5 2 2 JUMPER Jumper PS 1 can be removed to turn off the power supply 5 2 3 LOCK DELAY The lock delay is the time delay between receiving an activation signal and initiating an automatic open cycle and is selectable The time delay can be set to 0 second 1 second and 2 seconds The lock delay is set to 0 from the factory and does not need to be adjusted for most installations Figure 4 Power Supply Cabinet Components 120VAC LINE VOLTAGE JUMPER PS 1 CONNECTION 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 6 of 14 5 2 4 5 2 5 5 2 6 5 2 7 All switches set to off
9. RO INSTALLATION AND OPERATING INSTRUCTIONS document number 700002 included with the door operator A Fail Secure 24VDC 1A maximum power Electric lock is installed Protective barrier caution warning tape has been set up to prevent unauthorized access to work area Power has been shut off The 24V DC power supply cabinet contains an RF transmitter that is learned to the door operator The Power supply and Operators are numbered to ensure they remain as a paired set If the units get separated it will be necessary to sync the Power Supply assembly with the Door Operator Refer to section labeled Linking the RF Interface Module for instructions to link the Power Supply assembly and Door Operator 3 SYSTEM DESCRIPTION 3 1 General The ADA EZ Interface Module is shipped in the following components e ADA EZ TRD door operator Armored Door Cord 2 Door Cord Mounting Brackets 20 Feet of Operator Power and Signal wire Mounting Hardware 24VDC power supply with mounted Sensor Installation and Operation Manual 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 2 of 14 4 PRECAUTIONS 4 1 This product is intended for interior use only 4 2 The power supply must not be powered until all wiring is complete 4 3 The operator battery must be removed or switched to the OFF position until the installation of the operator is complete 4 4 An operating door creates pinch hazards Be careful making operating adjustment
10. erator completes and automatic open cycle The Door Operator remains in HOLD OPEN while the LED on the DK12 sensor is lighted The Door Operator remains in HOLD OPEN for 5 seconds after the LED light goes off Once the door begins to close the operator will ignore the signal from the presence sensor The Door Operator closes and remains closed 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 13 of 14 10 TROUBLESHOOTING INSTRUCTIONS 10 1 Refer to the Table Below for a listing of fault symptoms and recommended remedies Table 2 Troubleshooting Recommendations Symptom Recommended Remedy The Operator does not Learn Open Position when pressing the Activate Pushbutton OR The Operator does not Open when pressing the Activate Pushbutton The RF transmitter in the Power Supply assembly is not learned to the Door Operator Refer to section labeled Linking the RF Interface Module for instructions to link the Power Supply assembly and Door Operator The Electric Lock does not unlock Verify that the contact is closing when the activation buttons are pressed Verify that the power supply for the electric lock is powered Verify that the electric lock is a Fail Secure lock The Electric Lock unlocks but the Operator does not open Verify that the Interface Module RF is learned to the Door Operator Controls 1 On the Opertor Control board PRESS and HOLD LEARN PRESS and RELEASE
11. interface module is linked to the door operator controller when shipped from the factory If the interface module is replaced the module will need to be linked to the Operator Controller NOTE 9 1 7 If further door adjustments are necessary refer to the Section titled Customizing the Operator Settings in the ADA EZ PRO INSTALLATION AND OPERATING INSTRUCTIONS document number 700002 included with the door operator and PERFORM adjustments 9 2 Linking the RF Interface Module 9 2 1 9 2 2 9 2 3 The RF transmitter supplied with the power supply is linked to the door operator at the factory If the RF memory is reset or the RF transmitter is replaced the Operator must be manually linked with the RF transmitter To link an Interface Module with a door controller PERFORM the following a PRESS and HOLD the LEARN pushbutton on the controller until LEDs DS8 through DS11 flash green The controller shall shall remain in the learn mode for 20 seconds or until the RF signal is received b PUSH the Activation Pushbutton LED DS7 shall flash green indicating that the operator accepted this RF pushbutton To remove all RF pushbuttons from memory PERFORM the following e While pressing and holding the LEARN pushbutton on the controller PRESS and RELEASE the RESET pushbutton 9 3 Verify the function of the Door Operator 9 3 1 Press the activations buttons The Electric Lock unlocks The Door Op
12. s while the door is moving 4 5 All wiring must comply with all local state and national electrical codes All wiring must be secured to prevent it from becoming entrapped in the moving parts of the operator or door 4 6 The installation must be fully complete and verified for proper function or the door must be disabled prior to the installer leaving the installation An incomplete installation may cause serious injury Figure 1 Power Supply Cabinet with Sensor 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 3 of 14 Figure 2 Mounting the Power Supply Cabinet DETECTION AREA TOP VIEW DK 12 SENSOR MOUNTED TO POWER SUPPLY TRASH SENSOR RECEPTACLE MOUNTING HEIGHT FRONT VIEW 910002 Rev B 2013 ADA EZ ALL RIGHTS RESERVED 4 of 14 5 INSTALLING AND MOUNTING THE COMPONENTS 5 1 Mounting the Power Supply Cabinet 5 1 1 The power supply must be mounted in a location where the sensor will have a clear line of sight to the required detection area This location can be above the trash receptacle on an adjacent wall or above the door operator 5 1 2 The mounting distance from the floor to the bottom of the sensor must be a minimum of 7 ft Refer to Figure 2 which shows the Sensor area The sensor area is dependent on the mounting height and angle of the sensor according to the Table 1 below The mounting angle may be adjusted as shown in Figure 3 Table 1 Mounting Angle Aa B 7 3 20