Home
DRCR.NET Image Acquisition Protocol Optical Coherence
Contents
1. O oe ome DR 6 3 SYSTENTSTART ANBDXEOGIN ERR ONERE E NEEE TS E a 4 MANAGINGSTUDY PATIENT DATA 4 1 rx tare een aseo 8 5 PATIENT EXAM cc a a 5 1 EXAMININGBATIENITS aon nal 11 5 2 DEVICE TYRE 2 13 5 3 OGT IMAGE ACQUISITION m O 14 5 4 SCAN CONTROLS nests ew ott nce ae cine air cat a E LR E series tas seu 15 5 5 OCT ACOUISITION WIND O hos ta iicet ea ral 17 5 6 SCAN CONFIGURATION AND ACCEPTABILITY eu ya Er ae aeta eR ERR RUF 18 6 EXPORTING DATA 5550 EV GER IAS VERSA TE Ra ALAS VERAS EE IAS VIR ATE VR RU VAS VEA
2. juste ty has Manji Avance Parcs IL Spe Bav LIA A Pria ca Il Figure 13 Examine Window Please go to Tools User Preference from the menu Ensure that 3D Macular scan in RT Scan Pattern is set to its default of 6 x 6 mm see Figure 14 below If itis not set to 6 x 6 mm please change it Afterwards click OK to exit out of the User Preference window LL D RT Scan Pattern Cores Long Cornea Short Line 2 12mm 8 00 mm HD Line 2 12mm 6 00 moy Cross Une 2 12mm 10 00 mm Cross Line 2 12mm 800 mm 30 2 10 1 6 600 X 6 00 Figure 14 Default 3D Macular scan setting DRCR net RTVue OCT Procedures 12 5 2 Device Type selection 5 2 1 Please select 3D Macular from the Retina tab on the left Figure 15 This will ready the Examine To Do list with the 3D Macular scan I x Line Cross Line 3D Macular xr Raster MM6 E 3D Reference Grid v OD v OS of Scans 1 Examine To Do List Scan Type Io 3D 3D Macular Figure 15 Device Type Window DRCR net RTVue OCT Procedures 13 5 2 2 Checking the OD OS boxes above the Examine To Do List will determine which eyes will show up on the Examine To Do List Once the list is ready you can start a scan in these 3 manners 5 2 2 1 Double click
3. betaesus L S Local Disk Ww Local Disk x Local Disk Y Figure 4 Accessing the Tools gt gt Folder Options dialog box from Windows Explorer window 2 4 1 3 In the Folder Options dialog box click the View tab see Figure 5 2 4 1 4 Under the Advanced settings tree uncheck the checkbox next to Hide extensions for known file types and click the OK button DRCR net RTVue OCT Procedures MyComputer Offline Files Folder views fou can apply the view such Details or Tiles that you are using for this folder to all folders Apply ta All Folders All Folders Advanced settings Files and Folders Automatically search for network folders and printers Display file size information in folder tips Display simple folder view in Explorer s Folders list C Display the contents of system folders Display the full path in the address bar Display the full path in the title bar C Da not cache thumbnails Hidden files and folders Do not show hidden files and folders Show hidden files and folders Hide extensions for known file types E E E E Ed E E ee Bo 1 Restore Defaults Apply Figure 5 Unchecking the Hide extensions checkbox 3 System Start and Login Please refer to the user manual for your RTVue system to turn on the hardware and launch the supporting software to reach the database screen
4. Insurance Middle Ethnicity Disease Category Date of Birth MM dd yyyy ate of Birth yey 01 08 1376 JAcVue RTVue Study Gender Male Hequire Field AMD Female Example amp n Example Refraction tHE 9 OD dpt 05 0 dpt Best add new Birdshot Retinopathy Diagnosis Code Category Figure 27 ReVue Patient Information screen with Subject ID field DRCR net RTVue OCT Procedures 24 6 6 Exporting Raw Scan data from ReVue 6 6 1 raw scan data export steps for ReVue are identical to those detailed above for RTVue in Section 6 2 except for two points 6 6 1 1 You SHOULD check the Anonymous checkbox in the Output Selection window see Figure 22 for this final export 6 6 1 2 Now you are exporting to the final data folder you created in the previous step 6 7 Exporting Data into Xml Format from ReVue 6 7 1 From the ReVue application main menu select File gt gt Export gt gt Xml Figure 28 RTVue Tools OCT Image Database Management Home Help Print Setup Frink Header Info Data Transfer Current vist Import Current Scan ArchivelRetrieve Batch Process Clean Diagnosis Data Clean and Batch Process All Patients Exit Clinical Eric ramum Tera Figure 28 Exporting Data into XML 6 7 2 A window will pop up like the one below Figure 29 6 7 2 1 Make sure t
5. Section 6 6 1 6 2 6 Click the Start Output button on the bottom left corner of the window to begin exporting the files i L fe M O2 2008 02 36 M 3 Scans Sat By RAST visit E j CoreeScane iC Te fle L_ 29 2008 11 14 9M Tene Crema AMD Early LT te 1 May 25 2000 05 14 i dar Traction e 1 May 26 2008 05 11 Fites By AMD Moda Puber Phresiciuan L 7 Muy 26 2000 03 99 4 meme 9 Protocol Select Patent xpand Anoryenous Figure 22 Output Selection window Seve and Cot 6 2 7 Click the OK button when the Output Done window pops up DRCR net RTVue OCT Procedures 20 Output Done 4 scans output successfully From CRTOCTVIEW RawData and O scans nok Found in CARTOCTVIEWARawData Mote Data is not saved vet until click Saye and Exit button 6 2 8 Click the Save and Exit button in the Output Selection window Figure 22 to complete the process 6 3 Importing Raw Scan data from your temporary location into ReVue 6 3 1 From the ReVue application select File gt gt Data Transfer gt gt Input Data Figure 23 I Untitled RTWue Print Setup Print Header Info Output Data Import Archive Retrieve Batch Process Clean Diagnosis Data Exit Figure 23 Imp
6. earlier and click the Select button The export process will begin automatically 6 7 4 After export process is completed you should have a specific set of exported files and folders in your final export data folder as shown in Figure 30 below DRCR net RTVue OCT Procedures 26 0039 0363G0 Optovue RT ue mi x File Edit View Favorites Tools Help ae prm Back j Search 22 Folders Address C itempiO0s9 0363G0 Optovue RTvue a Mame Size Type Date Modified DiagnosisData File Folder 412112010 5 46 PM _JExportData File Folder 412112010 5 47 PM File Falder 412112010 5 46 OutputDE IBE 1 090 KB File 4 21 2010 5 46 PM Patients xml SKE XML Document 412112010 5 45 PM 2 SMILExportResulk txt 1 Text Document 4 21 2010 5 45 File and Folder Tasks c Make a new Folder 22 Publish this Folder to Ehe web E3 Share this Folder gt Other Places temp Documents My Computer Figure 30 Expected contents of target export folder and export steps are complete 7 Upload Data You will use the DRCR net Image Upload application to upload your exported SD OCT study data This is an updated version of the same software that your site may have previously used to upload large digital image files associated with Photography or Fluorescein Angiogram visits Please obtain the user manual and the installation software for v
7. shown below Figure 6 DRCR net RTVue OCT Procedures 1 B Datatane t i 1 7 Vetere Lhe ots n lorro hurt 1255 55 I imio am Figure 6 RTVue Patient Folder On the left side all patients in the database are listed These patients can be organized by physician disease name and date of visit On the right hand side the patient and visit information is displayed 4 Managing Study Patient Data 4 1 Create or Open a Patient File 4 1 1 To open an existing patient file select the patient name and click on the New Examination button to start the new examination Confirm that you wish to re examine the patient by clicking Yes DRCR net RTVue OCT Procedures 24083 4083 DOB 03 27 1936 Dec 21 2006 C Jun 06 2007 10 02 AM 20 Scans E Dec 21 2006 09 34 AM 20 Scans H Jun 21 2006 10 06 AM Mar 01 2006 11 00 AM 18 Scans Figure 7 Patient Information 4 1 2 Tocreate a new patient record click on the New Patient button Figure 7 4 1 3 Inthe Patient Information window Figure 8 the following info is required last name first name date of birth and gender sex Other fields do not need to be filled in for DRCR net study purposes and the specific values that you enter for Last Name First Name DOB and Gender are irrelevant as long as they are not empty Patient Information Last Mame Ethnic
8. the scan name 5 2 2 2 Highlight the scan name single click then click on the SCAN button at bottom center 5 2 2 3 Press the joystick button 5 3 OCT Image Acquisition 5 3 1 Align patient pupil with center of scan and move through pupil 5 3 2 Adjust distance to patient to get the best fundus IR image view of fundus from edge to edge there may be dark areas on either side when imaging the optic disc 5 3 3 Hold scanner head still and click on the Auto button if no scan is visible in the scan window 5 3 3 1 This will in turn perform the Auto Z Axial length Auto F Focus to offset the refractive condition and Auto P Polarization to adjust for differences in the device and patient polarizations Auto Manual Advanced Auto All Auto Average DRCR net RTVue OCT Procedures 14 5 3 3 2 If desired you can also perform the optimization functions individually by clicking once in the scan window using the mouse scroll wheel to bring scan to target area and then clicking the Auto Z Auto F and Auto P buttons individually 5 3 4 Adjust scan positioning in the fundus area visible in the live IR image if it is not where you wish it to be by 5 3 4 1 Double clicking the mouse cursor in the center of where you want the scan to be done IR image or Click and hold down on left mouse button with cursor on scan pattern drag to desired location and release the left mouse button 5 3 5 Optimize the scan
9. DRCR NET Image Acquisition Protocol Optical Coherence Tomography Using RTVue OCT 1 PROCEDURE SUMMARY FOR EXPERIENCED USERG ccecceccccccccccccccccccccccccccccccccccccccccccccccccccccccccccceccccccccccecccccceccccccecccs 1 1 ENSURE THAT YOUR RTVUE SYSTEM MEETS SYSTEM REQUIREMENTS cccecccceccccecccccccceccececceceecececcecescececseceececeeceeeceeeeceueecs 2 1 2 ACQUIRE SD OCT SCAN RESCAN S FOR STUDY EYE S PER PROTOCOL SPECIFICATION 2 1 3 EXPORT RAW SCAN DATA FROM YOUR RTVUE STATION AND IMPORT IT INTO YOUR REVUE STATION 1 2 1 4 EXPORT SCAN DATA AND XML TO NEW EMPTY FOLDER NAMED WITH STUDY ID AND VISIT eese eem 2 1 5 UPLOAD DATA TO COORDINATING CENTER USING DRCR NET IMAGE UPLOAD CLIENT 2 2 2 M 2 1 ENSURE THAT THE RTVUE SOFTWARE ON YOUR OCT MACHINE IS VERSION 4 0 5 39 OR 4 2 2 ENSURE THAT THE REVUE SOFTWARE ON YOUR SEPARATE NON OCT COMPUTER IS VERSION 4 0 5 59 2 4 2 3 XNMILEXPORT CONFIGURATION EEE posed eee d sau du 5 2 4 WINDOWS EXPLORER CONEIGURATIDNS tuus
10. MEAS SAY IA 6 1 CREATING A TEMPORARY FOLDER TO MOVE SUBJECT VISIT DATA FROM RTVUE 102102 19 6 2 EXPORTING RAW SCAN DATA FROM RI VUE soeur eet S eom cecus ioa to Ee sana eine 19 6 3 IMPORTING RAW SCAN DATA FROM YOUR TEMPORARY LOCATION INTO 21 6 4 CREATING A TARGET EXPORT FOLDER TO CONTAIN YOUR FINAL EXPORTED DATA e reae 24 6 5 ADDING THE DRCR NET SUBJECT ID TO YOUR VISIT DATA 6 sess sese sese rei 24 6 6 EXPORTING RAW SCAN DATA FROM REVUE zi orto e exse penis vex Mr edv otv ve Ex Eee dee PERO ROME 25 6 7 EXPORTING DATA INTO XML FORMAT FROM REVUE esse esse esses erui 25 7 UPEOA D DAT IEEE DRCR net RTVue OCT Procedures 1 Procedure Summary for Experienced Users 1 1 1 2 1 3 1 4 1 5 Ensure that your RTVue system meets system requirements 1 1 1 System Requirements Section 2 for details on system configuration minimum software version and required custom software Acquire SD OCT scan rescan s for study eye s per protocol spe
11. OCT Procedures 5 2 4 Windows Explorer Configuration Make sure that Windows Explorer is NOT set to Hide extensions for known file types 2 4 1 Follow the steps below if you are unsure how to do this 2 4 1 1 Double click on the My Computer icon to open the Windows Explorer window 2 4 1 2 menu see Figure 4 My Computer File Edit View Favorites Help i d Address 4 My Computer Folders Synchronize E Desktop 4 El Documents Computer Ed 31 Floppy 4 4 Local Disk C HH o CD Drive D i sys an File Server anapost F ES apps on appsrv1 5 7 jum on anapasisvsluserl amp AsStaFPworkingF jum an betaweb betawebey K isite on betabast Ez jsite on BetaPub Wweb bebapubweb Ps x isite on betaweb betaweby 1511 E3 on betaweb betawebey H A an heFaeziie fll Map Network Drive Disconnect Network Drive In the Windows Explorer window choose Tools gt gt Folder Options from the Jha Flopp Local Disk CD Drive D DS sys an File Server anapost F 59 apps an 1 5 ilum on anaposTsysYuseryAAStaffWworkingFolders 9 ilum an betaweb rbetawebz K S isite an betabast M 9 jsite an BetaPubWweb betapubweby Sw jsite betaweb betaweb 5 3 jsite an betaweb betawebey T 59 jsite
12. Window DRCR net RTVue OCT Procedures 17 5 6 Scan Configuration and Acceptability 5 6 1 You should use the standard 3D Macular scan with no custom configuration of any kind with the default 6 x 6 mm scan pattern shown in Figure 14 above 5 6 2 Try to obtain scan quality SSI of 35 or higher for the scans that you obtain for DRCR net studies 6 Exporting Data Because DRCR net requires extra data that can only be exported from OptoVue s ReVue software you will need to move your subject data from RTVue to ReVue prior to doing the full export The necessary sequence is as follows 1 Export your subject visit data from RTVue to a temporary folder 2 Import the subject visit data into ReVue from your temporary folder 3 Export the subject visit data from ReVue including both raw data and XML data Please refer to the remainder of this section for a detailed explanation of the steps involved in this sequence DRCR net RTVue OCT Procedures 18 6 1 Creating a temporary folder to move subject visit data from RTVue to ReVue 6 1 1 Create an empty folder in a temporary location that is either on your network and accessible from other computers or else is located on a flash drive 6 1 2 Example folder names include TEMP J039 0246RU 10 week and TEMP O039 0246RU Optovue RTVue for protocol J and O respectively 6 2 Exporting Raw Scan data from RTVue 6 2 1 From the RTVue application start the raw scan data export process by choosin
13. You should never perform any analysis activities using the ReVue software or modify your acquired DRCR net data in any way there so there is no need to be concerned about data overwrites Upon completion of the import process a popup message will appear to confirm that the import is complete Click the Exit button to return to the main patient list Creating a target export folder to contain your final exported data 6 4 1 6 4 2 As with your temporary transfer folder above create an empty folder to hold the final exported data you will be generating using ReVue You do not have to create this folder on a network location or flash drive if you will be uploading the final data directly from the ReVue computer Example folder names would be identical to the temporary folder you created above except do not include the word TEMP in the folder name Examples include JO39 0246RU 10 week O039 0246RU Optovue RTVue for protocol J and O respectively Adding the DRCR net Subject ID to your visit data in ReVue 6 5 1 Patient Information Last Mame Patient ID First Mame Test Open up the imported patient record in ReVue and note that there is a field for Subject ID Figure 27 After clicking the Edit button at the bottom of the form enter the DRCR net subject ID into this field and click Save to save the record prior to performing any export steps from ReVue subject ID 0004 807622
14. cification 1 2 1 Macular scan 1 2 2 Scan quality SSI gt 35 at minimum green bar if possible Export raw scan data from your RTVue station and import it into your ReVue station 1 3 1 scan data is exported by selecting the visit and choosing File gt gt Data Transfer gt gt Output Data 1 3 2 Export to a temporary location on your network that is accessible from other computers or else export to a flash drive Example folder names include TEMP J0O39 0246RU 10 week and TEMP O039 0246RU Optovue RTVue for protocol J and respectively 1 3 3 Input the data into ReVue by choosing File Data Transfer Input Data Select the OutputDB IB file and select the patients to input Export scan data and XML from ReVue to a new empty folder named with Study ID and Visit 1 4 1 Example folder names include JO39 0246RU 10 week and O039 0246RU Optovue RTVue for protocol J and respectively 1 4 2 Patient s Study ID e g J039 0246RU or O039 0246RU must be entered into the Subject ID field of the patient record prior to export 1 4 3 Foreach visit perform the following two export steps 1 4 3 1 Export raw scan data to your empty target export folder by selecting the visit and choosing File gt gt Data Transfer gt gt Output Data 1 4 3 2 Export scans as an XML file to your target export folder by selecting visit and choosing File Export Xml 1 4 4 Export process sho
15. col v E Sort By LastName T PATIENT NAME v Search By First Name nop TEST DRCR Middle Name Initia e of Birth MM dd yyyy Gender Jan 29 2010 04 25 4 Scans Apr 12 2010 10 46 AM 6 Scans Refraction 9 OD dpt 05 Require Field Figure 11 RTVue Patient Folder New Visit DRCR net RTVue OCT Procedures 10 TE i Ele Tools Database Management Home Patient Examine 2010 10 49 AM RTVue PatientList Current Patient p Filter By 4 Physician v Patient Information Protocol wv E Sort By Last Name D L PATIENT v pearen 24 First Name DACA Middle Name TEST Gender Jan 29 2010 04 25 PM 4 5cans A Apr 12 2010 10 46 AM 6 Scans Refraction OD dpt OS i g Apr 12 2010 10 49 AM 0 Scans Require Field Figure 12 RTVue Patient Folder multiple visits on same day 4 1 5 2 When you export the data see below you should only export the visit containing the scans acquired for the DRCR net study 5 Patient Exam 5 1 Examining Patients After all patient information has been entered either by new patient or new visit clicking the Examine tab will bring you to the Examine page Figure 13 DRCR net RTVue OCT Procedures 11
16. ersion 2 0 of this software application under the Study Documents section of the DRCR Web site www DRCR net DRCR net RTVue OCT Procedures 27
17. g File gt gt Data Transfer Output Data Figure 20 RTYue Image Database Management Home Help Cece 1 pm Pi we Print Setup Print Header Info Data Transfer Output Data Export Input Data Import aj Archive Retrieve Batch Process Clean Diagnosis Data Clean and Batch Process All Patients tient Information Last Name Patient First Test Middle Name Initial Exit Date af Birth 01 08 Patient Test Gender 47 C Female Refraction HH HH OD 0 dr Require Field Figure 20 Exporting Raw Data 6 2 2 A Save As pop up window will be displayed Browse to the empty patient folder that you created earlier and click Save Figure 21 Sew in 1 CODEC giras FL Tue L X sd Fir IB Places 3 Figure 21 Save As Pop up Window DRCR net RTVue OCT Procedures 19 6 2 3 After clicking the Save button you will be redirected to the Output Selection window Figure 22 6 2 4 Make sure to select the appropriate single visit by putting a check mark in its checkbox Use the search tools on the right hand side of the window to locate your subject if necessary 6 2 5 Be sure NOT to select the Anonymous checkbox during your initial export from the RTVue capture software Only select this box during your subsequent export from the ReVue software see
18. ity First Name Date of Birth Misi Disease Category Gender Male Female Refraction 8 HH OD dpt 05 0 dpt add new amp n Example amp n Example Require Field Diagnosis Code Category Figure 8 Patient Record Window DRCR net RTVue OCT Procedures 4 1 4 Under the Patient Information window is the Visit Information Figure 9 The Visit Information window allows you to edit visit information such as writing comments Underneath you can save edit or cancel any changes to a patient Figure 10 Visit Infomation Visited Date Visit Time Physician Operator Comments Figure 9 Visit Information Window Save Cancel Figure 10 Visit Information Options 4 1 5 To keep from exporting data that is not needed for DRCR net study purposes and was only obtained for clinic purposes a new visit can be created to include only the necessary Protocol O data 4 1 5 1 To create a new visit under the Patient tab click the New Visit button Figure 11 Fill in the physician and operator and select Save There should now be two visit entries for the same visit date as shown in Figure 12 E File Tools OCTImage Database Management Home Help Patient PatientList Current Patient Filter By _ Physician _ E Disease Patient Information Proto
19. n Information DRCR net RTVue OCT Procedures 4 2 3 XML Export configuration 2 3 1 Make sure ReVue is set to advanced mode 2 3 1 1 n ReVue go to User Preference from Tools under the Menu Figure 2 Test DOB 01 08 1976 RTYue File Pat OCT Image Database Management Home Help Copy Examine List Paste Examine List Fi Sync Calibration Scan Pattern Management Protocol Management Patient Information Last Mame Patient First Name Test Middle Mame Initial Clean Unused Scans From visit Mops ioo eel Date of Birth MM dd wyyy 0170871376 Gender 8 Male C Female Refraction OD 0 dp Os i Figure 2 User Preference Clear Log File Change Password User Preference Reset System 2 3 1 2 the top right drop box make sure User Interface Setting is set to Advanced Figure 3 Afterwards click to exit out of the box Date Format MMiddiyyyy w User InterFace Setting Advanced of pages for Raster Radial slicer and Grid Allow to save eye blink data 185 k Clinical Tab Setting ato M Fixation LED Current 20 10007 Auto All Setting Verify RPE tips before Yes Auto Play Scan video saving scan Quality Setting video Enhancement Yes v 3D Sum um Save 7x7 SLO raw data 2 Pages Auto detect 3D baseline Yes while saving scan Figure 3 User Preference Window DRCR net RTVue
20. o select the appropriate single visit by putting a check mark in its checkbox Use the search tools on the right hand side of the window to locate your subject if necessary 6 7 2 2 Besure to select the Anonymous checkbox and the Export to a single XML file checkbox 6 7 2 3 Onthe right hand side select the 3D Macular checkbox to ensure that the 3D Macular scans you acquired for the study are exported 6 7 2 4 Once you are finished click the OK button at the bottom of the form DRCR net RTVue OCT Procedures 25 09 Sm L 7 May 2008 01 39 Scone 53 AMO E arhy LT ow Mee 25 72008 098 14 AM LASK AE prete Toom SU Co May 29 2008 12 14 7 xara Very Seul PED L 2006 27 6 PY J carm Vireo meade Trachon se L May 26 2008 02 11 AM C Crops Line Dire HD Cross Line hasu Lines Gnd LINE 3D Protocol Zadra Retna Steele Sana Domen lobes C Sandy 7 Stands dO ena Serle SC air SOC Bare Folios Redert yo d acces 9 Deport fo 9M ww 9 amp nomemous Figure 29 Exporting Data into XML Cont 6 7 3 The Choose Folder window is displayed Navigate to and select the final export data folder that you created
21. orting data into ReVue 6 3 2 window will open allowing you to choose where the OutputDB IB file is located Figure 24 DRCR net RTVue OCT Procedures 21 187 5 Desktop OP 3 MSOCache 29 4eb2187955cfe 893375236bcec405 C3 Downloads dell C3 Documents and Settings drivers My Computer OutputDB IB a whe i eS My Network InterBase Fles 18 zl Places Figure 24 Choosing your exported OutputDB IB file to import into ReVue 6 3 3 Click the OutputDB IB file that you previously exported and then click the Open button 6 3 4 Click the No button in the window asking whether to leave the RawData folder in place in order to save space on the hard drive of the computer Figure 25 Figure 25 Prompt whether to leave files in the import location or not 6 3 5 window will open containing all patients and visits that were exported from the RTVue device Figure 26 DRCR net RTVue OCT Procedures 22 P L Aq V 6 Coroni TEILT LY LLL Figure 26 Screen for selection of data for import into ReVue DRCR net RTVue OCT Procedures 23 6 4 6 5 6 3 6 6 3 7 6 3 8 6 3 9 Choose your subject s exported data by using the check boxes in the left window Click the Insert New Data Only button If you are prompted whether it is OK to overwrite existing data in ReVue click the Yes or button to allow the overwrite
22. signal strength image quality using position X Y Focus or P Motor Look for the high GREEN bar on the right side of the live scan window 5 3 6 Capture scan by pressing the joystick button 5 3 7 Save the scan 5 4 Scan Controls 5 4 1 Starting Stopping and Saving a Scan r V EE y Figure 16 Button presentation before starting a scan Figure 17 Button presentation while in live scanning mode Capture Acquire the data scan Cancel abort scanning Initiates a scan DRCR net RTVue OCT Procedures 15 Restart scanning process Save scan pa Figure 18 Button presNatation after acgfiiring stopping scan 5 4 1 1 Scan Patterns with multiple captures Use the Arrows to scroll through other captured scan sets scans with multiple captures DRCR net RTVue OCT Procedures 16 5 5 Acquisition Window 5 5 1 Description Once you push the Scan button on the Control Panel Figure 16 you will see the OCT Acquisition Window Figure 19 Please note that the live images are always displayed in the top half of the screen Signal Strength Index SSI OD MME 55 61 8 40 Maru Advanced image E 2 034 gt on Length 2 Tn Dismeti d Stan Wih hrn Arje Video 16 255 170 0 4 gt 295 N OF Diplis A Cumert Fiare No 2 4 1 ec 9 Fr Figure 19 OCT Acquisition
23. t gt About RTVue from the menu 2 1 2 If you do not have 4 0 5 39 or higher please contact the Coordinating Center to determine if you can still participate using the version that you have 2 2 Ensure that the ReVue software on your separate non OCT computer is version 4 0 5 59 2 2 1 Thisis a custom release of the ReVue software from Optovue intended specifically to support DRCR net You will need to download the installer for this version of ReVue from the Information for Investigators section of the DRCR Public Web site www DRCR net 2 2 2 Please note that this software does not come with a standard uninstaller and may be difficult to remove completely from a computer once installed For more information about uninstallation please contact Optovue and inquire about detailed instructions for removal of the various components of ReVue software from a computer 2 2 3 You check your current software version by launching ReVue and selecting Help gt gt About ReVue from the menu Figure 1 2 2 4 Following installation please contact the Coordinating Center to obtain a license key and activation instructions for your ReVue software About Revue x For Clinical Trial Use Only Version 4 0 5 59 2004 2010 Optoyue All Rights Reserved Request Code 930 8937 77 21 B Activate Code D 135 44FD DE55 Activated Version Loca Figure 1 ReVue Software Versio
24. uld produce three folders inside your target export folder DiagnosisData ExportData and RawData one OutputDB IB file a Patients xml file and an X MLExportResults txt file Upload data to Coordinating Center using DRCR net Image Upload Client software 1 5 1 Thisis an updated version of the same software that is used to upload DRCR net fundus photography data 1 5 1 1 You must download and install version 2 0 of this software even if you already have the older version installed for photography uploads 1 5 2 Software can be obtained from the Study Documents section of the DRCR Web site www DRCR net DRCR net RTVue OCT Procedures 2 System Requirements In addition to the RTVue instrument software that Optovue includes with its OCT machines there is a special offline or review version of Optovue s software called ReVue To use an Optovue OCT machine in a DRCR net study at the present time you must install this offline ReVue software on a separate non OCT computer Please see the remainder of this section for version requirements and please refer to the remainder of this document for detailed procedures about how you will use both the RTVue software and the ReVue software to acquire and export study data DRCR net RTVue OCT Procedures 3 2 1 Ensure that the RTVue software on your OCT machine is version 4 0 5 39 or higher 2 1 1 You can check your current software version by launching RTVue and selecting Help g