Home
Flexineb™ User Manual
Contents
1. N General If the equipment is not maintained or is used in a manner not specified by the manufacturer the electrical safety protection provided by the equipment may be impaired MS 080 Rev 00 Aug 2011 12 Troubleshooting The nebulizer will not start The nebulizer is slow The aerosol chamber does not empty when the horse inhales The horse becomes uneasy during use Things to check Check cable connections Check that battery is charged Check status of LEDs Fig 4 Check if there are liquid drops on underside of the medication cup and shake off if present The nebulizer flow rate will depend on the medication used Check that the battery is charged Wash the medication cup per instructions The medication cup is at the end of its life and must be replaced Check that vents in bottom of mask are closed and exit valve is inserted and working correctly Check that mask is fitted properly and creating a good seal around the horses muzzle Some horses may reject the smell or taste of some medications and become uneasy during use Check that the Inlet Valve and Exit Valve are functioning correctly Fig 2 If you still experience problems with your Flexineb system please visit www nortev com call Nortevs customer service line at 353 0 91 79 97 78 MS 080 Rev 00 Aug 2011 Table 1 Troubleshooting 13 Warranty The following warranty protection applies to system components Mask Assembly excludes
2. inlet and exit valve 12 months The valves are wearing parts and are not covered by warranty protection Medication Cup The medication cup is a wearing part and its life is very dependent on the drug used and how well it is maintained between uses therefore the medication cup component is not covered by warranty protection Controller and Cable 12 months Battery 6 months Power Supply 12 months Any damage caused by improper handling is not subject to warranty protection The warranty expires when the device has been interfered with by a third party MS 080 Rev 00 Aug 2011 14 Compliance The Flexineb system complies with the essential requirements of the following European Directives and Harmonised Standards Directives DIRECTIVE 2004 108 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC DIRECTIVE 2006 95 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits Harmonised Standards EN61326 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN610004 11 EN61010 1 MS 080 Rev 00 Aug 2011 15 Contact For general technical and scientific information check out our website www nortev com To or
3. should be in an upright position e Activate the MDI just before the inhalation phase of the horse 5 Mask Assembly r1 gt ipie 4 ES i M r3 Rotate Aerosol Chamber xc dis SM to the horizontal position Ra M m Metered Dose Inhaler MDI not supplied in upright position Adaptor for MDI Figure 5 Flexineb Metered Dose Inhaler Use MS 080 Rev 00 Aug 2011 11 Maintenance N Mask When washing the mask remove the nebulizer and controller To maintain the function and life of the mask and its paris it must be washed in warm soapy water and rinsed with clean water after every use AN Medication Cup Cover the medication cup electrical connector with the supplied Protective Silicone Cap prior to washing Do not immerse the medication cup in water To maintain the function of the medication cup C it must be washed after each use Put a few e drops of washing up liquid and clean warm water in the medication cup close the Cap and shake it Genily squeeze the Cap to push x warm water through the mesh Rinse out AS ur afterwards with clean warm water Shake off AY any water before re using Ly lt is essential that the water is clean otherwise it may clog the mesh AN Controller To maintain the function of the electronic controller it must be used and stored in dry conditions To maintain the battery function it must be charged when the assigned LED flashes green Fig 5
4. Ce neo Portable Equine Nebulizer System User Manual nortev TM Table of Contents INTENDED USE 5 5 083 28 3 480 a bear asian a eai cio NR Rea a SECUS 3 SAFETY INFORMATION wsssssscccssassssstassocsassacesstesssescsonecsesedssssscssesssnseasss 3 TECHNICAL SPECIFICATION vssstessscsiccectssebeassdssesssossbesessessssssvosssseeses 4 INSTRUC TIONS FOR USE assadas edestesecestendsacstestecssseussadsdtiiecsosendsenses 6 MAINTENANCE epp 12 TROUBLESHOOTING ssssesscccsccsssesssssstsscssssencccssscsseesssnscasescesesesoscanseecss 13 WARRANTY aereoa tvi E pn av nita 14 COMPLIANCE ienien 15 CON TAG D ssi ni vet e Nn M da 16 MS 080 Rev 00 Aug 2011 2 Intended Use The Flexineb is a portable equine nebulizer system intended to aerosolize veterinarian prescribed liquid solutions into a fine mist for inhalation into the airways of the horse N The end user is liable for the safe operation of the Flexineb and its parts as outlined in this user manual N Medications must be prescribed by a veterinarian and end users should follow the advice of their veterinarian at all times Safety Information When using the Flexineb for the first time remember it is the first time for the horse too so caution is advised ooftly place the Flexineb over the horses nose and mouth with the bottom grey valve open so the horse can breathe normally Push up until the nostrils are covered and a seal is made around the
5. Open the vents at the bottom of the mask by rotating the exit valve housing Fig 2 This helps the horse become familiar with the device Fill the medication cup with medication or saline strictly following the advice of your veterinarian Fig 3 After the above steps fit the Flexineb to the horses head ensuring a good seal is created between the head and the mask Secure the mask in place using the mask straps For safety reasons stay with the horse at all times during the nebulization process When the horse is familiar with the device close the vents in the bottom of the mask by rotating the exit valve housing Fig 2 This activates the Inlet and Exit Valves MS 080 Rev 00 Aug 2011 6 Fig 4 Switch on the Controller to begin the nebulization process After a few seconds the Aerosol Chamber will begin to fill with aerosol and clear as the horse inhales the aerosol On completion of the nebulization process switch off the controller Alternatively the controller will switch off automatically after 15 minutes complete Medication Cup Aerosol Chamber MS 080 Rev 00 Aug 2011 P i j Remove the Flexineb from the horse once nebulization Is Clean the device between uses as described in the Maintenance section of the manual Ir os i i i i i f LAA Long Strap i F pol 4 Short Strap i i ts aM M i Figure 1 Flexineb Nebuli
6. der replacement paris visit our online shop at www nortev com For Customer Service call 353 0 91 79 97 78 Postal Address Nortev Limited Unit 18 Corporate Park Claregalway Co Galway Ireland MS 080 Rev 00 Aug 2011 16
7. ion rechargeable battery pack Use the Nortev supplied battery only Use of another type of battery may present a risk of fire or explosion Battery Operating Time gt 3 hours from fully charged MS 080 Rev 00 Aug 2011 4 VAN Battery Charging The battery can be charged using the Nortev supplied Charger Use the Nortev supplied charger only Use of an alternative charger may present a risk of fire or explosion The battery charging time is approximately 2 hours A Mains Power Supply As a backup to battery power the Flexineb can also be operated using the Power Supply provided with the system The same Power Supply charges the battery Use the Nortev Power Supply only Use of an alternative Power Supply may present a risk of fire or explosion Power Supply Charger Details Input 100 240V 50 60Hz 250mA Output 9V 1 0A AN Environmental Conditions Operating 5 C to 45 C and up to 95 RH Storage and Transportation 20 C to 45 C and 15 to 95 RH MS 080 Rev 00 Aug 2011 5 Instructions for Use The Flexineb system is very simple to set up and use There are two modes of use 1 Flexineb Nebulizer System 2 Flexineb Mask with Metered Dose Inhaler Flexineb Nebulizer System Before fitting the Flexineb to the horses head check the following Check that the system is assembled Fig 1 Check the Inlet Valve is moving freely Fig 2 Check the Exit Valve is moving freely Fig 2
8. nose and mouth Once the horse is breathing normally and is getting used to the Flexineb shut the bottom valve by twisting the grey valve and commence treatment If the horse is resisting the mask be patient and let them look at it and smell it before attempting to fit the mask again If the horse starts to get scared during treatment slightly open bottom grey valve so more air is being inhaled Close the valve again once the horse is relaxed In an emergency situation the blue exit valve on the bottom of the mask can be pulled out of its grey housing to allow the horse breathe freely Although the mask material is soft and flexible the front aerosol chamber and battery controller is hard plastic therefore caregivers should be mindful of the risk posed by the horse shaking its head with the Flexineb fitted MS 080 Rev 00 Aug 2011 3 Technical Specification Flow Rate Typically 21 0 ml min with 0 9 NaCl solution The nebulizer flow rate is dependent on the drug used Aerosol Particle Size Typically 50 of particles generated are less than 5 microns VMD measured using Malvern Spraytech with 0 996 NaCl solution Medication Cup Volume The medication cup will hold 10ml of liquid but is expandable to 30ml using the plug in extension cup supplied The controller has a 15 minute timer therefore if the extension cup is used the controller will need to be re started to complete the dose AN Battery Power Battery Type 7 4V Li
9. zer System 7 J Mask Seal Air Inlet Valve Aerosol jm Chamber a f j j f f f Exit Valve housing Vents can be rotated to Vents Closed Vent Open or Vent Open Position Closed position Position Figure 2 Flexineb Mask MS 080 Rev 00 Aug 2011 Extension Cup total volume d with extension cup is 30ml Fixed Medication Cup 10ml Electrical Connector Figure 3 Flexineb Medication Cup Cable output to Medication Cup Controller Cable Back Up Power Supply Battery and Battery Charger Battery Door Figure 3 Flexineb Controller Cable and Power Supply MS 080 Rev 00 Aug 2011 9 LED1 LED Off 2 System Off Continuous Green System On Flashing Green Low i Flexi m Battery lexico LED3 e e LED Off 5 C G Battery ok or LED2 Q i system off a ok or AN Coninuoene y Green Battery Flashing Amber Check Charging cable is connected correctly Continuous Amber Contact Nortev if On Off Switch Figure 4 Flexineb Controller Functions MS 080 Rev 00 Aug 2011 10 Flexineb Mask with Metered Dose Inhaler MDI The Flexineb can be used with a Metered Dose Inhaler as shown in Fig 5 e Rotate the Aerosol Chamber to a horizontal position e Use the MDI adaptor supplied and insert it into the end of the Aerosol Chamber e Close the vents at the bottom of the mask Fig 2 e Insert the MDI into the MDI Adaptor e The MDI
Download Pdf Manuals
Related Search
Related Contents
MOEN 2080CH Instructions / Assembly iPhone Developer Program User Guide ATLAS- user manual - V1,0 Copyright © All rights reserved.
Failed to retrieve file