Home
        User Manual - DITI17320140
         Contents
1.                                               Part  No  Description Qty   1 SCREW M8X50 3  2 Overfall plug 1  3 plug G1  1  4 O RING 29 82x2 62 1  5 machined pump head 1  6 O RING 58 42x2 62 1  7 internal rotor 1  8 external rotor 1  9 flexiseal rotry 1  10 pin 5x15 2  11 SCREW M6X25 4  12 pump flange 1  13 motor 1  14 water proof switch 1  15 tongue 2  16 by pass plug 1  17 O RING 17 12x2 62 1  18 Pressure relief valve adjustment screw 1  19 O RING 11 1 1 78 2  20 compression helical spring 1  21 by pass valve 1  22 venting kit 1                   
2. 9     Limits and methods for measuring radio disturbance characteristics  EN55014 2 97     Electrical motor     operated and thermal appliances for household and similar  purposes  electric tools and similar electrical apparatus   EN60204 1 98    Safety of machinery     electrical equipment of machines    2  Machine Description    Pump  Electric self priming rotary internal gear pump  equipped with a by pass valve  Motor  Asynchronous motor  single phase  4 pole  closed type  Protection class IP55    self ventilating  flange mounted directly to the pump body     3  Technical Information    3 1 Electrical Information                                        ELECTRICAL POWER POWER   Pressure  PUMP MODEL   Current  Voltage Frequency   Nominal 5 Flow Rate  Maximum   V   HZ   watt   17320090 AC 230 50 550 12 BAR 9LPM  17320091 AC 230 50 750 25 BAR 9LPM  17320140 AC 230 50 750 12 BAR 14LPM  17320092 AC 380 50 550 12 BAR 9LPM  17320093 AC 380 50 750 25 BAR 9LPM  17320141 AC 380 50 750 12 BAR 14LPM  17320100 AC 120 60 550 145 PSI   10 quarts min  17320101 AC 120 60 750 290 PSI 10 quarts min  17320180 AC 120 60 750 145 PSI   18 quarts min                         ATTENTION   The power absorbed by the pump depends on the functioning point and the viscosity of the oil being  pumped     4  OPERATION CONDITIONS    4 1 Environmental Conditions   Temperature  Min  10  C   max 60  C   Relative Humidity   max 90    ATTENTION    The temperature limits indicated are applied to the pump components 
3. AC Gear type Oil Pump    User   s Manual       A WARNING  Read carefully and understand all  INSTRUCTIONS before operating  Failure to follow the  safety rules and other basic safety precautions may result  in serious personal injury     1  DECLARATION OF CONFORMITY    DECLARATION OF CONFORMITY    IN CONFORMANCE WITH THE DIRECTIVES  98 37 EEC  MACHINERY   73 23 EEC  PRESSURE VESSELS   89 336 EEC  ELECTOR MAGNETIC COMPATIBILITY     THE MANUFACTURER  INTRADIN  SHANGHAI  MACHINERY  118 DUHUI ROAD  MINHANG DISTRICT  SHANGHAI  201109 CHINA    DECLARES THAT THE FOLLOWING PUMP MODELS  17320090  17320091  17320092   17320093  17320140  17320141  17320100  17320101  17320180  CONFORMS TO THE FOLLOWING EUROPEAN REGULATIONS     EN292 1 92     Safety of Machinery     General Concepts  basic principles for design     terminology   basic methodology   EN292 2 92     Safety of Machinery     General Concepts  basic principles for design      specifications and technical principles   EN294 93     Safety of Machinery     safe distances to prevent the operator   s upper limbs from  reaching dangerous areas   EN60034 1 2000     Rotating electrical Machinery     nominal and functional specifications  EN60034 5 2001     Classification of grades of protection for the housings of rotating electrical  machinery   EN61000 6 3     Electro     magnetic compatibility     generic emission standards   EN61000 6 1     Electro     magnetic compatibility     generic immunity standards  EN55014 1 00 A1 99 A2 9
4. and must be respected to   avoid possible damage or malfunction    It is understood  nevertheless  that for a given oil  the real functioning temperature range also   depends on the variability of the viscosity of the oil itself with the temperature  Specifically    e The minimum temperature allowed   10  C  could cause the viscosity of some oils to greatly  exceed the maximum allowed  with the consequence that the static torque required during the  starting of the pump would be excessive  risking overload and damage to the pump    e The maximum temperature allowed   60  C  could  on the other hand  cause the viscosity of  some oils to drop well below the minimum allowed  causing a degradation in performance with  obvious reductions in flow rate as the back pressure increases     4 2 Electrical Power  Depending on the model  the pump must be fed by single phase alternating current whose nominal  values are those indicated in the Table of paragraph 3 1 Electrical information     The maximum acceptable variations from the electrical parameter are   Voltage   5  of the nominal value  Frequency   2  of the nominal value    ATTENTION   Electrical power from lines with values outside the limits indicated can cause damage to the    3       electrical components    4 3 Working Cycle   Under normal operating conditions they can function continuously with no limitations    ATTENTION    Functioning in by pass conditions is only allowed for brief periods  2 minutes maximum    Whenever a 
5. ar by pass functioning    Deliver until the air in the  by pass system is purged       Presence of the air in the oil    Wait for the oil in the tank to  settle          LEAKAGE FROM THE  PUMP BODY       Damage to the mechanical  seal       Check and replace the  mechanical seal       10  MAINTENANCE    On a weekly basis check that the hose joints have not loosened  to avoid any leakage  On a monthly basis check the pump body and clean it removing any impurities    On a monthly basis check and clean the filters placed at the pump inlet    On a monthly basis check that the electric power cables are in good condition     11  NOISE LEVEL    Under Normal operating conditions noise emission for all models does not exceed the value of 70  db    A    at a distance of 1 Meter from the electric pump     12  EXPLODED DIAGRAMS AND SPARE PARTS  Model No  17320090  17320092  17320140  17320141  17320100  17320180                                                                Part  No  Description Qty   1 SCREW M8X50 3  2 Overfall plug 1  3 plug G1  1  4 O RING 29 82x2 62 1  5 machined pump head 1  6 O RING 58 42x2 62 1  7 internal rotor 1  8 external rotor 1  9 flexiseal rotry 1  10 pin 5x15 2  11 SCREW M6X25 4  12 pump flange 1  13 motor 1  14 water proof switch 1  15 tongue 2  16 by pass plug 1  17 O RING 17 12x2 62 1  18 compression helical spring 1  19 by pass valve 1  20 venting kit 1  21 O RING 11 1 1 78 2                      Model No  17320091  17320093  17320101                  
6. e gear type oil pumps are self priming and therefore  able to draw oil from the tank even when  the suction hose is empty on start up  The priming height  distance between the surface of the oil  and the inlet opening  must not exceed 2M     WARNING  Wetting the pump  Before starting the pump  wet the inside of the pump body with oil through the  inlet and outlet openings     If the pump is already installed  the wetting operation can be performed by unscrewing the  threaded plug of the inlet opening not in use  by filling the internal chamber with oil and screwing in  the plug  paying attention to the O ring seal     If no foot valve is installed  it is advisable to leave the purge valve always open so that once the  device is re started again  it is ready to purge the air present in the suction tube  Please consider  that during the operation  a small part of oil re circulates in the tank    If a foot valve is installed  close the air purge valve by turning it clockwise  so that no oil circulates  in the tank  If the foot valve seal is not perfectly tight  the suction tube may be emptied and the  purging operation described above must be repeated     The priming phase may last from several seconds to a few minutes  depending on the   characteristics of the system    If this phase is excessively prolonged  stop the pump and verify    e That the pump is not running completely    dry      e That the suction hose guarantees against air infiltration and is correctly immersed in 
7. fety systems       Rotor blocked    Check for possible damage or  obstruction to rotating parts       Thermal motor protector has  triggered    Wait until the motor cools  verify  that it starts again  look for the    cause of overheating       Problems with the motor    Contact technical support       Motor turns slowly when  starting    Low voltage from the  electrical power supply    Adjust the voltage within  anticipated limits       Excessive oil viscosity    Verify oil temperature and warm  it to reduce excessive viscosity       LITTLE OR NO FLOW    Low level in the suction tank    Fill in the tank       Foot valve blocked    Clean and or replace valve       Filter blocked  Excessive suction pressure    High load loss in the delivery  circuit  running with by pass  open     Lower the pump with respect to  the level of the tank or increase    Clean the filter    the cross section of the hose  Use shorter hose or of wider  diameter       By pass valve blocked    Detach the valve  clean or          replace it  Air in the pump or suction Check the seal of the  hose connection  Narrowing of the suction Use a hose appropriate for  hose working under suction pressure       Low rotation speed    Check the voltage at the pump   Adjust the voltage or use cables    of greater cross section       Excessive oil viscosity    warm it to reduce the excessive    Verify the oil temperature and    viscosity       HIGHER PUMP NOISE    Cavitation    Reduce the suction pressure       Irregul
8. ion     6 4 SUCTION  amp  DELIVERY LINES   DELIVERY   The choice of pump model to use should be made keeping in mind the viscosity of the oil to be  pumped and the characteristics of the system attached to the delivery of the pump  The  combination of the oil viscosity and the characteristics of the system could  in fact  create back  pressure greater than the anticipated maximums  equal to P max   so as to cause the  partial   opening of the pump by pass with a consequent noticeable reduction of the flow rate supplied    In such a case  in order to permit the correct functioning of the pump equal to the viscosity of the oil  being pumped  it will be necessary to reduce resistance in the system by employing shorter hoses  and or of larger diameter    On the other hand  if the system cannot be modified it will be necessary to select a pump model  with a higher Pressure     SUCTION  The gear type oil pumps are characterized by excellent suction capacity  In fact  the characteristic  flow rate back pressure curve remains unchanged even at high pump suction pressure values     At the initial start up  the maximum priming height can reach 2M when the suction hose is empty  and the pump is filled by the fluid  So during this period  the height between the pump  amp  fluid should  be less than 2M  If exceed this height  it would be better to assemble a foot valve or use a larger  diameter suction hose  It is suggested never install a pump over 3M height     7  INITIAL START UP    Th
9. particular installation carries the risk of functioning in by pass mode for longer periods  of time  it is necessary that the by passed flow not be recirculated inside the pump  but be returned  to the suction tank     4 4 Fluid Allowed   Fluids Not Allowed    ALLOWED  Oil with a Viscosity from 50 to 2000 Cst  at working temperature                             NOT ALLOWED RELATED DANGER  Gasoline  Petrol  Fire   explosion  Inflammable liquids with PM  lt  55  C Fire   explosion  Water Oxidation of the pump  Liquid food products Contamination of same  Corrosive Chemicals Corrosion of the pump  Injury to people  Solvents Fire     explosion  Damage to gasket seals             ATTENTION   The gear pump is sensitive to those polluted fluid  DO NOT deliver the fluid contained too much  impurity     5  MOVING AND TRANSPORTING    Given the limited weight and size of the pumps  See dimensions and weights   moving the pumps  does not require the use of lifting equipment     The pumps are carefully packed before shipment  On receipt  check the packing materials and  store in a dry place     6  INSTALLATION    6 1 Preliminary Inspection   e Check that the machine has not suffered any damage during its transport or warehousing   e Clean the inlet and outlet openings with care  removing any dust or packing residue      Make sure that the motor shaft turns freely    e Check that the electrical information corresponds with what is shown on the label     6 2 Mechanical Installation  The gear 
10. pumps can be installed in the following ways     a  Onan horizontal base           rl   meS       7 En  gt   AO       b  With the pump body upwards             WARNING  DO NOT install the pump vertically with the pump body downwards        Do not install the pump at the inflammable  amp  steamy place   If absolutely necessary  install a foot valve and fill the suction tube with oil during the first priming  phase     Fix the pump using screws of a diameter suitable for the provided fixing holes as indicated in the  drawing     6 3 HYDRAULIC CONNECTION     Make sure that the hoses and the suction tank are free of dirt and filling residue that might  damage the pump and accessories    e Always install a metal mesh filter in the suction hose      Before connecting the delivery hose  partially fill the pump body with oil to avoid the pump  running dry during the priming phase     The MINIMUM recommended characteristics for hoses are as follows   SUCTION HOSE     Diameter  1        Nominal pressure  2 times the pressure P bypass     Appropriate for use with suction   DELIVERY HOSE     Diameter  1 2        Nominal pressure  2 times the pressure P bypass    ATTENTION    The use of hoses and or line components that are inappropriate for use with oil or have inadequate  nominal pressures can cause damage to objects or people as well as pollution    The loosening of connections  thread connections  flanges  gasket seals  can likewise cause  damage to objects or people as well as pollut
11. the fluid  to be drawn   e That any filters installed are not blocked   e That the priming height is not greater than 2M   e That the delivery hose allows for the easy evacuation of the air   When priming has occurred  after reattaching the delivery gun  verify that the pump is functioning   within the anticipated ranges  possibly checking    1  that under conditions of maximum flow the energy drawn by the motor falls within the values   indicated on the label   2  that the back pressure in the delivery line does not exceed the values indicated in paragraph 6 4   SUCTION  amp  DELIVERY LINES    8  EVERY DAY USE    8 1 Manual Operation   1  Before starting the pump  make sure that the ultimate shut off device  delivery gun or line valve   is closed    2  Turn the on switch   3  Make sure that the tank is filled with a quantity of oil greater than the quantity to be supplied   running dry could damage the pump    ATTENTION   Never start the pump by simply inserting the plug in the outlet    4  Open the delivery valve or activate the delivery gun  gripping it securely    5  Close the delivery gun or the line valve to stop delivery  The pump will immediately enter  by pass mode   ATTENTION   Running in by pass mode with the delivery closed is only allowed for brief periods  2 to 3 minutes  maximum     6  Stop the pump    9  PROBLEMS AND SOLUTIONS       PROBLEM    POSSIBLE CAUSE    CORRECTIVE ACTION       Motor does not turn    Lack of power    Check electrical connections  and sa
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
MANUAL DE INSTALACIÓN Y DE UTILIZACIÓN SISTEMA  FOS 66 User Manual rel 1.1 Eng  藍=0570-080-ー 00 受付時間=平日9=00~ーフ=00  3 - AutomationDirect  Manual de Usuario  Manuale d`uso  KE 2000 / 35 KE 2200 / 40 KE 2200 / 40 S - AL-KO  SA-GNV111D  Fujitsu TX100 User's Manual      Copyright © All rights reserved. 
   Failed to retrieve file