Home
Platinum™ Series
Contents
1. SUNOH osues LNOHLIM SLINN S LN3ILWd N33AAL38 39NVN3 LNIVH 3ALLN3A3HUd e3ey UU H294 uea Je3e 4 UO sano JO no ADNVNALNIVW 3AILLN3A3Ud NOI LO3dSNI HOV3 NO FIGURE 6 2 Preventive Maintenance Record Part No 1118353 24 Series Platinum SECTION 7 TROUBLESHOOTING GUIDE SECTION 7 TROUBLESHOOTING GUIDE SYMPTOM Alarm SHORT BEEPS LONG PAUSE Concentrator NOT operating power switch ON Alarm CONTINUOUS Concentrator NOT operating Power Switch ON PROBABLE CAUSE Main Power Loss Power cord NOT plugged in 2 No power at outlet 3 Tripped circuit breaker System Failure la Remove and clean cabinet Unit overheating due to blocked air intake SOLUTION Insert plug into outlet 2 Inspect house circuit break ers or fuses If problem recurs use a different outlet 3 Call Service Provider filters Ib Move oxygen concentrator at least three inches away from walls draperies or furniture 2 Insufficient power at outlet 2 DO NOT use extension cords Move to another elec Beeeeeeeep 5 TTC trical outlet or circuit 3 Internal repairs 3 Call
2. DETAIL Humidifier Bottle DETAIL Adapter Access Door Humidifier Bottle Adapter FIGURE 5 3 Attaching the Humidifier Bottle Adapter 7 Attach oxygen tubing from the humidifier bottle to oxygen outlet connector on the oxygen concentrator FIGURE 5 4 8 Attach the cannula patient supply tubing to the humidifier bottle outlet FIGURE 5 4 9 After assembly ensure that oxygen is flowing through the cannula Part No 1118353 17 Platinum Series SECTION 5 OPERATING INSTRUCTIONS Oxygen Outlet Connector Oxygen Tubing Humidifier Outlet FIGURE 5 4 Attaching the Oxygen Tubing Power Switch NOTE For this procedure refer to FIGURE 5 5 on page 18 1 Press power switch to on position All the panel lights and the audible alarm will come on for one second indicating that the unit is functioning properly On Off VO Power Switch FIGURE 5 5 Power Switch Platinum Series 18 Part No 1118353 SECTION 5 OPERATING INSTRUCTIONS Flowrate NOTE For this procedure refer to FIGURE 5 6 on page 19 1 Turn the flowrate knob to the setting prescribed by your physician or therapist CAUTION Never set the flow greater than 10L min A WARNING DO NOT change the L min setting on the flowmeter unless a change has been prescribed by your physician or therapist NOTE To properly read the flowmeter locate the prescribed flowrate line on the flowmeter Next turn th
3. 15 Select a Location rione nnn a a a e aa a a aia 15 Sete 8 15 Pl g in Power iia meminere e P ERE 15 Connect Humidifier If So Prescribed l6 Power Switch e eeeeeeseeseeeeeee ener tne tete 18 FIO Wat Cased na cote EUT pe EAT oul sei a 19 Front Panel Indicators Units with 2 20 Initial Startup of the 20 Front Panel Indicators Units without SensO2 21 Initial Startup of the Concentrator sss 21 SECTION 6 MAINTENANCE 00000000000000000000000000000 22 Part No 1118353 3 Platinum Series TABLE OF CONTENTS Routine Mliritenance ai poet b tabat eee Decke 22 Cleaning the Cabinet Filter eere 22 Cleaning the Cabinet 23 Cleaning the Humidifier 23 SECTION 7 TROUBLESHOOTING GUIDE 25 LIMITED WARRANTY 090000000000000000000000000000000000 27 Platinum Series 4 Part No 1118353 SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage Refer to the following table for definitions of the signal words SIGNAL WORD MEANING Danger indicates an imminently hazardous situation A DANGER
4. 6 Call Service Provider GREEN LIGHT with YELLOW Light Flashing Internal repairs required Call Service Provider Platinum Series 26 Part No 1118353 LIMITED WARRANTY LIMITED WARRANTY NOTE THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4 1975 This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare Corporation or a dealer This warranty is not extended to any other person or entity and it is not transferable or assignable to any subsequent purchaser or owner Coverage under this warranty will end upon any such subsequent sale or other transfer of title to any other person This warranty gives you specific legal rights and you may also have other legal rights which may vary from state to state Invacare Corporation warrants its Platinum 10 Oxygen Concentrators when purchased new and unused to be free from defects in materials and workmanship for a period of three years from date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty DO NOT OPEN OR ATTEMPT TO SERVICE THE 4 WAY VALVE BODY This will void any and all warranty applicable to the valve body If within such warranty periods any such product shall be proven to Invacare Corporation s satisfaction to be defective such product shall be repaired or re
5. Clean the cabinet with a mild household cleaner and non abrasive cloth or sponge Cleaning the Humidifier NOTE To clean the oxygen humidifier follow the instructions provided by the manufacturer If none are provided follow these STEPS 1 Clean the humidifier every day 2 Wash it in soapy water and rinse it with a solution of ten parts water and one part vinegar e Rinse thoroughly with hot water and refill with distilled water to the level shown on the humidifier Part No 1118353 23 Platinum Series SECTION 6 SERIAL NO IRC MODEL NO supak 10 5 Jad s pp Jad sunoy pz sanoy Qgz 9z 9 10 yaam sad skop sad pz 8 o1 sunoy OBE ALON 1 2 9 Jo uonoes 1 31ON 5507 peu 191114 IJU 4osseJduuo 2940 19949 Vd3H PRNO 2345 e ejdey ueo 5 Deu 14 SHNOD H3A3HOIHA 5 OH 087 97 Osues SLINN 5507 Je od peu 349114 IJU 2940 aJU Vd3H PRNO pu 5 4 3euiqe e ejdey ueo 5 peu
6. Service Provider required Alarm Potential Obstruction l Inspect for kinks or RAPID Alert blockages Correct clean or la Possible internal replace item Once Beep Beep obstruction in the oxygen corrected turn power OFF Beep Beep path for 60 seconds and then turn Ib Kinked or blocked tubing cannula or humidi fier power back ON 2 Flowmeter set too low 1 0 L min or less 2 Possible internal obstruction in the oxygen path 3 Reset flowmeter to pre scribed flowrate Part No 1118353 25 Platinum Series SECTION 7 TROUBLESHOOTING GUIDE SYMPTOM YELLOW or RED LIGHT Illuminated Alarm CONTINUOUS On red light only Only applies to SensO models PROBABLE CAUSE Low oxygen purity SOLUTION Clean or Replace filters 2 Kinked or blocked tub ing cannula or humidifier 2 Inspect for kinks or block ages Correct clean or replace item Once corrected turn power OFF for 60 seconds and then turn power back ON 3 Flowmeter set too low 1 0 L min or less 3 Check flowmeter is set to 1 0 L min or more 4 Unit overheating due to blocked air intake 5 Insufficient power at outlet 6 Internal repairs required 4 a Remove and clean cabinet filters 4b Move concentrator at least three inches from walls drap eries and furniture 5 DO NOT use extension cords Move to another elec trical outlet or circuit
7. while waiting for the O purity to reach maximum LABEL O PURITY INDICATOR LIGHTS SYMBOL LED O SYSTEM OKAY GREEN Indicator Light 2 O over 8576 YELLOW Indicator light A YELLOW Solid B YELLOW Flashing Sensor Failure Call a qualified technician Have a back up supply of oxygen ready O Between 73 to 85 SYSTEM FAILURE RED Indicator Light Continuous Audible Alarm Sieve GARD Compressor Shutdown Call a qualified technician Switch to a back up supply of oxygen immediately O Below 73 Platinum Series 20 Part No 1118353 SECTION 5 OPERATING INSTRUCTIONS Front Panel Indicators Units without SensO NOTE For this procedure refer to FIGURE 5 8 Auto Shut Down Use Backup a e Call Supplier Normal GREEN FIGURE 5 8 Front Panel Indicators Units without SensO2 Initial Startup of the Concentrator NOTE Concentrator may be used during the initial start warm up time approximately 30 min O purity will build to a maximum during this period LABEL STATUS INDICATOR LIGHTS SYMBOL LED SYSTEM OKAY GREEN Indicator Light SYSTEM FAILURE RED Indicator light Continuous Audible Alarm Sieve GARD Compressor Shutdown Call a qualified technician Switch to a back up supply of oxygen immediately Part No 1118353 21 Platinum Series SECTION 6 MAINTENANCE SECTION 6 MAINTENANCE A WARNING The Invacare concentrators ar
8. INCIAL LAWS AND REQUIREMENTS Invacare Corporation www invacare com USA 9 2013 Invacare Corporation All rights One Invacare Way reserved Republication duplication or Elyria Ohio USA modification in whole or in part is 44036 2125 prohibited without prior written Ye 800 333 6900 permission from Invacare Trademarks Technical Services are identified by and 9 All trademarks 800 832 4707 are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Part No 1118353 Rev K 07 13
9. IONS AND EXCLUSIONS THE FOREGOING WARRANTY SHALL NOT APPLY TO PRODUCTS SUBJECTED TO NEGLIGENCE ACCIDENT IMPROPER OPERATION MAINTENANCE OR STORAGE SOOT OR SMOKE FILLED ENVIRONMENTS OR OTHER THAN NORMAL APPLICATION USE OR SERVICE OR TO PRODUCTS MODIFIED WITHOUT INVACARE CORPORATION S EXPRESS WRITTEN CONSENT INCLUDING BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS OR TO PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE CORPORATION OR TO PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND INVACARE CORPORATION S CONTROL THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE PROV
10. This equipment is to be used as an oxygen supplement and is not considered life supporting or life sustaining Platinum Series 6 Part No 1118353 LABEL LOCATION LABEL LOCATION IRCIOLX IRCIOLXO2 HomeFill Compatible AQ HomeFill Compatible BQ a P SEE USER MANUAL OR e SEE USER MANUAL OR EQUPMENTPROVIDERFOR MO O EQUPMENTPROVDERFOR _ O9 SAFE OPERATING INSTRUCTIONS ALARMS AUDIBLE ALERTS AND USE OF ACCESSORIES SAFE OPERATING INSTRUCTIONS ALARMS AUDIBLE ALERTS AND USE OF ACCESSORIES A DANGER RISK OF FIRE NO SMOKING OPEN 69 FLAME OR IGNITION SOURCES Keep ALL sources of ignition out of the room in which this product is located and away from areas where oxygen is being delivered Textiles oil and other combustibles are easily ignited and burn with great intensity in oxygen enriched air DANGER RISK OF ELECTRIC SHOCK DO NOT remove cover Refer servicing to qualified service personnel A DANGER RISK OF FIRE NO SMOKING OPEN QQ FLAME OR IGNITION SOURCES Keep ALL sources of ignition out of the room in which this product is located and away from areas where oxygen is being delivered Textiles oil and other combustibles are easily ignited and burn with great intensity in oxygen enriched air A DANGER RISK OF ELECTRIC SHOCK DO NOT remove cover Refer servicing to qualified service personnel ZX CAUTION Federal USA law restricts this device to sale ZX CA
11. UTION Federal USA law restricts this device to sale by or on the order of a physician by or on the order of a physician PIN 1125073 Rev PIN 1130062 RewC _ Serial Number Label is located on the resonator intake assembly Specification Label is located on the back near the bottom Part No 1118353 7 Platinum Series SECTION GENERAL GUIDELINES SECTION GENERAL GUIDELINES In order to ensure the safe installation assembly and operation of the Platinum concentrator these instructions MUST be followed A WARNING This section contains important information for the safe operation and use of this product To Reduce the Risk of Burns Electrocution Fire or Injury to Persons A DANGER Risk of electric shock DO NOT disassemble Refer servicing to qualified service personnel No user serviceable parts Avoid using while bathing If continuous usage is required by the physician s prescription the concentrator MUST be located in another room at least 7 ft from the bath DO NOT come in contact with the concentrator while wet DO NOT place or store product where it can drop into water or other liquid DO NOT reach for product that has fallen into water Unplug IMMEDIATELY If the concentrator has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water call qualified technician for examination and repair A s
12. User Manual Platinum Series Oxygen Concentrators Standard with SensO and HomeFill Invacare 10 with SensO Invacare 10 Model IRCIOLXO2 Model IRCIOLX Dealer This manual MUST be given to the end user User Before using this product read this manual and save for future reference For more information regarding Invacare products parts and services please visit www invacare com Yes you can WARNING A WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner s manuals service manuals or instruction sheets supplied with this product or optional equipment If you are unable to understand the warnings cautions or instructions contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur A ACCESSORIES WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products ACCESSORIES There are many different types of humidifiers oxygen tubing cannulas and masks that can be used with this device You should contact your local home care provider for recommendations on which of these devices will be be
13. ain containers and packing materials for storage until use of the concentrator is required Inspection Inspect examine exterior of the oxygen concentrator for nicks dents scratches or other damages Inspect all components Storage 1 Store the repackaged oxygen concentrator in a dry area 2 DO NOT place objects on top of repackaged concentrator Platinum Series 12 Part No 1118353 SECTION 4 TYPICAL PRODUCT PARAMETERS SECTION 4 TYPICAL PRODUCT PARAMETERS Electrical Requirements Rated Current Input Altitude above sea level without degradation of concen tration levels Oxygen Output 87 to 95 676 for flows ranging 2 L to 10 L min Concentration Levels Maximum Outlet Pressure psi 0 5 psi 62 0 kPa 3 45 kPa NOTE Stated concentration levels achieved after initial warm up period approximately 30 minutes Flow Range i i The concentrator detects a condition that may indicate a potential obstruction of the output oxygen Rapid audible beeping alert this alert is deacti vated when accessories are connected May be associated with flow setting of L min or less Average Power Consumption S85W Pressure Relief Mechanism 5 psi 3 5 psi 241 kPa 24 1 kPa Operational at hange in maximum recom 0 7 L min mended flow when back pres sure of 7kPa is applied Filters abinet 2 Outlet HEPA and Compressor Inlet afety System urrent overload or line surge shutdown High temperature
14. asal cannula Clinical studies have documented that oxygen concentrators are therapeutically equivalent to other types of oxygen delivery systems Your provider will show you how to use your oxygen concentrator He She should be contacted with any questions or problems regarding your oxygen concentrator This owner s manual will tell you about your concentrator and will serve as a reference as you use your concentrator Select a Location A WARNING NEVER block the air openings of the product or place it on a soft surface such as a bed or couch where the air opening may be blocked Keep the openings free from lint hair and the like Move oxygen concentrator at least 3 inches away from walls draperies or furniture You may select a room where using your oxygen concentrator would be most convenient Your concentrator can be easily rolled from room to room on its casters The air intake of the unit should be located in a well ventilated area to avoid airborne pollutants and or fumes DO NOT place ina closet Set Up Plug in Power Cord Plug in power cord to an electrical outlet Part No 1118353 15 Platinum Series SECTION 5 OPERATING INSTRUCTIONS A POLARIZED PLUG WARNING As a safety feature this appliance may have a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit c
15. compressor shutdown High Pres sure Alarm w compressor shutdown Low Pres sure Alarm w compressor shutdown Battery Free Power Loss Alarm SensO Oxygen System Possible Obstruction Alert Operating Ambient 50 F 95 10 C 35 20 60 relative po E ess than Ambient 45 F 257 Part No 1118353 13 Platinum Series SECTION 4 TYPICAL PRODUCT PARAMETERS Oxygen Output Less than Ambient 8 F 4 4 Temperature abinet Resistant flame retardant plastic cabinet O nlt to UL 94 VO Regulatory Listing Double Insulated Product ETL certified comply ing with UL 1097 ETL certified to CSA C22 2 No 68 Electrical No extension cords extension cords Placement ELI closer than three inches from any wall fur niture draperies or similar surfaces Tubing 7 ft cannula with a maximum 50 ft o Crush Proof Tubing DO NOT pinch Recommended use up to 50 ft high flow tubing with high flow cannula at all flow rates Relative Humidity Time of Operation Op to 24 hours per day Recommended tories and Shipping Temperature tive hati Platinum Series 14 Part No 1118353 SECTION 5 OPERATING INSTRUCTIONS SECTION 5 OPERATING INSTRUCTIONS Introduction Your oxygen concentrator is intended for individual use indoors It is an electronically operated device that separates oxygen from room air It provides high concentration of oxygen directly to you through a n
16. e flow knob until the ball rises to the line Now center the ball on the L min line prescribed NOTE A Potential Obstruction Alert indicates a condition that be associated with a partial or complete obstruction of oxygen output 2 If the flowrate on the flowmeter ever falls below 1 L min for more than about one minute the Potential Obstruction Alert will be triggered This is a rapid beeping of the audible alarm Check your tubing or accessories for blocked or kinked tubing or a defective humidifier bottle After rated flow is restored to 1 L min the Potential Obstruction Alert will go off NOTE The use of some accessories such as the HomeFill compressor will deactivate the Potential Obstruction Alert Ball FIGURE 5 6 Flowrate Part No 1118353 19 Platinum Series SECTION 5 OPERATING INSTRUCTIONS Front Panel Indicators Units with SensO NOTE For this procedure refer to FIGURE 5 7 The SensO feature monitors the purity of oxygen generated by the oxygen concentrator If purity falls below factory preset standards indicator lights on the control panel will illuminate OXYGEN PURITY Auto Shut Down O Use Backup N S R ZU Call Supplier TN d supp Below Normal A e YELLOW Normal O2 FIGURE 5 7 Front Panel Indicators Units with SensO2 Initial Startup of the Concentrator NOTE Concentrator may be used during the initial start warm up time approximately 30 min
17. e specifically designed to minimize routine preventive maintenance Only qualified personnel should perform preventive maintenance on the concentrator Unplug the concentrator when cleaning To avoid electrical shock DO NOT remove cabinet NOTE At a minimum preventive maintenance MUST be performed according to the maintenance record guidelines In places with high dust or soot levels maintenance may need to be performed more often Refer to Preventive Maintenance Record on page 24 Routine Maintenance Cleaning the Cabinet Filter CAUTION DO NOT operate the concentrator without the filter installed NOTE For this procedure refer to FIGURE 6 1 on page 23 NOTE There are two cabinet filters one located on each side of the cabinet 1 Remove the filter and clean as needed NOTE Environmental conditions that may require more frequent cleaning of the filters include but are not limited to high dust smoking air pollutants etc 2 Clean the cabinet filters with a vacuum cleaner or wash in warm soapy water and rinse thoroughly 3 Dry the filters thoroughly before reinstallation Platinum Series 22 Part No 1118353 SECTION 6 MAINTENANCE Cabinet Filter FRx located on both E sides of concentrator a p FIGURE 6 1 Cleaning the Cabinet Filter Cleaning the Cabinet A WARNING UNPLUG the concentrator when cleaning To avoid electrical shock DO NOT remove cabinet
18. nd Power Indicator Lights Flowmeter Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter one of two shown ACCESSORIES NOT SHOWN HomeFill home oxygen compressor 200 REAR VIEW NOTE This outlet fitting is to be used only for filling oxygen cylinders with the HomeFill home oxygen compressor The outlet fitting does not affect concentrator performance Refer to the HomeFill owner s manual part number 1100873 for connection and operating instructions When not in use the plug provided with the Cord Fitting concentrator should be inserted into the outlet fitting For more information about the HomeFill contact your Invacare dealer Part No 1118353 Platinum Series SECTION 3 HANDLING SECTION 3 HANDLING The concentrator should ALWAYS be Kept in the upright position to prevent cabinet damage while being transported If the concentrator is to be reshipped by common carrier additional cartons are available from Invacare Unpacking NOTE For this procedure refer to FIGURE 3 1 1 Check for any obvious damage to the carton or PS its contents If damage is 2 AD A evident notify the di carrier or your local ac Q dealer 2 Remove all loose packing from the carton a gt 3 Carefully remove all the components from the rd carton FIGURE 3 1 Unpacking NOTE Unless the oxygen concentrator is to be used immediately ret
19. ontact a qualified electrician DO NOT attempt to defeat this safety feature Connect Humidifier If So Prescribed A WARNING DO NOT overfill humidifier DO NOT reverse the oxygen input and output connections Water from the humidifier bottle will travel through the cannula back to the patient NOTE For this procedure refer to FIGURE 5 1 FIGURE 5 2 and FIGURE 5 3 on page 17 and FIGURE 5 4 on page 18 NOTE Recommended humidifier is high flow MS0481 1 Remove cap and fill humidifier bottle with distilled water to the level indicated by the manufacturer 2 Replace the humidifier cap and securely tighten Humidifier Bottle FIGURE 5 2 Humidifier Compartment Platinum Series 16 Part No 1118353 SECTION 5 OPERATING INSTRUCTIONS Remove the filter access door located on the side of the concentrator Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door open Refer to Detail A in FIGURE 5 3 The humidifier adapter is next to the inlet filter Pull up and remove the humidifier bottle adapter Refer to Detail B in FIGURE 5 3 Attach it to the humidifier by turning the wing nut on the humidifier bottle counterclockwise until itis securely fastened Refer to Detail C in FIGURE 5 3 Place the humidifier bottle in the humidifier compartment Plate Groove Insert Flat Head Screwdriver Here Filter Access Door
20. placed at Invacare Corporation s option This warranty only applies to the labor for repairs performed by the Invacare Service Department or Invacare Authorized Service Centers It does not apply to the labor performed by the purchaser or user This warranty does not include normal wear and tear or shipping charges Invacare Corporation s sole obligation and your exclusive remedy under this warranty shall be limited to such repair or replacement Routine maintenance items such as filters are excluded from this warranty For warranty service please contact Invacare Corporation s Service Department at the toll free number on the back cover Upon receiving notice of an alleged defect in a product Invacare Corporation will issue a serialized return authorization It shall then be the responsibility of the purchaser to return the entire unit or remove at purchaser s cost the defective component part s identified pack the component part s in a manner to avoid shipping damage and to ship the component part s to either Invacare Corporation s plant or service center as specified by Invacare Corporation in advance Defective component part s MUST be returned for warranty inspection using the serial number as identification within thirty 30 days of return authorization date DO NOT return products to our factory without prior consent C O D shipments will be refused please prepay shipping charges Part No 1118353 27 Platinum Series LIMITAT
21. pontaneous and violent ignition may occur if oil grease or greasy substances come in contact with oxygen under pressure These substances MUST be kept away from the oxygen concentrator tubing and connections and all other oxygen equipment DO NOT use any lubricants unless recommended by Invacare Avoid creation of any spark near medical oxygen equipment This includes sparks from static electricity created by any type of friction Platinum Series 8 Part No 1118353 SECTION GENERAL GUIDELINES Operating Information For optimum performance Invacare recommends that each concentrator be on and running for a minimum of 30 minutes at a time Shorter periods of operation may reduce maximum product life Keep the oxygen tubing cord and unit out from under such items as blankets bed coverings chair cushions clothing and away from heated or hot surfaces including space heaters stoves and similar electrical appliances DO NOT move or relocate concentrator by pulling on the power cord NEVER drop or insert any object or liquid into any opening Invacare recommends that Crush Proof oxygen tubing be used with this product and not exceed 15 2 m 50 ft in length There are no user serviceable parts This does not include normal maintenance items See maintenance section for user maintenance items A product should NEVER be left unattended when plugged in Make sure the Platinum is Off when not in use Close supervision is necessa
22. ry when this product is used near children or physically challenged individuals Additional monitoring or attention may be required for patients using this device who are unable to hear or see alarms or communicate discomfort DO NOT connect the concentrator in parallel or series with other oxygen concentrators or oxygen therapy devices Radio Frequency Interference This equipment has been tested and found to comply with EMC limits specified by IEC EN 60601 1 2 These limits are designed to provide a reasonable protection against electromagnetic interference in a typical medical installation Part No 1118353 9 Platinum Series SECTION GENERAL GUIDELINES Other devices may experience interference from even the low levels of electromagnetic emissions permitted by the above standards To determine if the emissions from the Platinum is causing the interference turn the Platinum Off If the interference with the other device s stops then the Platinum is causing the interference In such rare cases interference may be reduced or corrected by one of the following measures e Reposition relocate or increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s is connected Platinum Series 10 Part 1118353 SECTION 2 FEATURES SECTION 2 FEATURES Oxygen Purity Indicator Lights SensO model only Fault Oxygen Outlet mw a
23. st for you They should also give you advice on the proper usage maintenance and cleaning The supply accessories nasal cannula mask tubing humidifier etc used to deliver oxygen to the patient may include a means to reduce the propagation of fire in the accessories for the safety of the patient and others Ifa commercially available fire activated flow stop device is used in the accessories setup it should be placed as close to the patient as practicable Platinum Series 2 Part No 1118353 TABLE OF CONTENTS TABLE OF CONTENTS ACCESSORIES cccccccccccccccccccccccccccccccsccsscccccccccce TABLE OF CONTENTS 3 SPECIAL NOTES ccccccccccccccccccccccccccccccccscccccccccce D LABEL LOCATION 66 7 SECTION GENERAL GUIDELINES 8 To Reduce the Risk of Burns Electrocution Fire or Injury to POISONS P 8 Operating oe toit d des 9 Radio Frequency Interference ssssesssessssssssssssssessesscesssseesees 9 SECTION 2 FEATURES 00000000000000000000000000000000000000 SECTION 3 HANDLING 000000000000000000000000000000000000 2 Unpacking T 12 12 aI a OA 12 SECTION 4 TYPICAL PRODUCT PARAMETERS 13 SECTION 5 OPERATING INSTRUCTIONS 15
24. which if not avoided will result in death or serious injury Warning indicates a potentially hazardous situation WARNING which if not avoided could result in death or serious injury Caution indicates a potentially hazardous situation CAUTION which if not avoided may result in property damage or minor injury or both NOTICE The information contained in this document is subject to change without notice A DANGER DO NOT SMOKE while using this device Keep all matches lighted cigarettes or other sources of ignition out of the room in which this product is located and away from where oxygen is being delivered NO SMOKING signs should be prominently displayed Textiles and other materials that normally would not burn are easily ignited and burn with great intensity in oxygen enriched air Failure to observe this warning can result in severe fire property damage and cause physical injury or death Part No 1118353 5 Platinum Series SPECIAL NOTES CAUTION Caution Federal law restricts this device to sale or rental by or on order of a physician or any other practitioner licensed by the law of the State in which he she practices to use or order the use of this device Invacare recommends an alternate source of supplemental oxygen in the event of a power outage alarm condition or mechanical failure Consult your physician or equipment provider for the type of reserve system required
Download Pdf Manuals