1. Ensure that the flue is perfectly vertical and the grab screws are tight gt t agii t Grab Screw 2 Engage the firebox with the bolt bearings as per the diagram below Black steel single skin lower flue Thrust ball bearings Washers Bearing holder p c 013 27 M12 nuts T um Safety split pin OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 8 3 INSTALLATION 3 4 Protecting the floor Any combustible floor beneath a fireplace must have a floor protector that extends 300mm beyond the diameter of the firebox in all directions e If installed directly on combustible material the floor protector must be made of a 20mm thick sheet of material with a thermal conductivity of 0 21W m K Non combustible finishes can be applied to the floor protector tiles steel sheet light concrete etc f the combustible floor is installed on concrete you can replace the combustible material with non combustible material laid directly onto the concrete FLOOR PROTECTOR LAID ON TIMBER FLOOR Combustible 300mm Insulative board 20 non combustible finish floor eg timber FLOOR PROTECTOR LAID ON JOIST mE Combustible 300mm floor eg timber Insulative board 20mm non combustible finish Eie etc EET NA NZ gt i OBLICA ERGOFOCUS IN
2. ERGOFOCUS INSTALLATION AND USER MANUAL 1 TECHNICAL DATA 2 PRE INSTALLATION 3 INSTALLATION 4 OPERATION TESTING Keep for future use OBLICA 200 Argyle St Fitzroy VIC 3065 03 9416 0400 1 TECHNICAL DATA WEIGHT AND DIMENSIONS Firebox diameter 950mm Firebox weight 63Kg Flue diameter 219mm Flue weight 16Kg meter Standard bracket weight 20Kg External flue kit Triple skin 200 250 300mm Nominal thermal output kW Efficiency 46 196 FIREBOX 0950 mm 006 OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 2 2 PRE INSTALLATION Congratulations on your purchase of the ErgoFocus This appliance should be installed and checked by a qualified professional Ensure you have read the operation guidelines thoroughly prior to first use For any questions or concerns please contact Oblica on 03 9416 0400 The installation process is outlined below Determine position of firebox and flue carefully observing the clearances described within this section Install the suspension bracket Install the external flue Install the internal flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation If such action is necessary consult the manufacturer i
3. LICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 11 9 TESTING TEST REPORT N ATL17 10 TESTING LABORATORY MANUFACTURER MODEL WORK REQUESTED TEST DATES RESULTS CONCLUSION OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL Testing Laboratory 6 26 Stirling st Thebarton 5 5031 08 8351 8056 Focus Atelier Dominique Imbert ErgoFocus open style fireplace Measure C02 levels as outlined in AS NZS 4013 1999 to determine if appliance is excluded from full testing to this standard 09 06 2010 The maximum carbon dioxide output by the appliance during the high burn rate prescribed in AS NZS 4013 1999 was 3 79 This appliance meets the requirements of AS NZS 4013 1999 section 1 2 3 f and is classified as an excluded appliance PAGE 12
4. STALLATION AND USER MANUAL PAGE 9 3 INSTALLATION FLOOR PROTECTOR LAID ON CONCRETE Combustible 300mm floor eg timber Non combustible finish eg tiles Concrete FIREBOX Floor protector S non combustible finish Combustible floor eg timber OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 10 4 OPERATION 4 1 What you should burn Untreated air dried hardwood Split logs with a humidity content of less than 20 4 2 Do not burn e Trash Painted plastic Coated or preservative treated wood e Waste or black coal Inflammable liquids Fire gels Moist wood with a residual humidity content of more than 20 this may cause soothing of the chimney IMPORTANT Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee The maximum load capacity for the ErgoFocus is 20kg of wood Burning only seasoned hardwood helps to protect the environment and lower emissions For details of a wood supplier in your area please call our office on 03 9416 0400 or email info doblica com au o Do not use flammable liquids or aerosols to start or rekindle the fire o Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of some types of preservative treated woods as a fuel can be hazardous OB
5. e pad CROSS BAR SET IN BETWEEN RAFTERS Plaster Ceiling Minimum Gap p CEILING FLANGE 150 12 SUSPENSION BRACKET CONNECTOR LOWER FLUE 219mm dia OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 5 3 INSTALLATION PITCHED ROOF INSTALLATION CUSTOM MADE BRACKET Custom Length amp Angle OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 6 3 INSTALLATION 3 2 Installing the external flue 1 Place the connection piece inside the suspension bracket This will join the single skin flue below the bracket and the triple skin flue above the bracket which have different diameters 2 Ensure the triple skin flue is installed as per Australian standards see diagrams below PITCHED ROOF INSTALLATION The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 8 meters from any higher section of roof gt 40 pe 28m gt 40 cm oe 2 40 cm p FLAT ROOF INSTALLATION LESS THAN 5 PITCH The top of the flue must be 1200mm above the roofline Alternatively there must be a minimum distance of 6 meters from any higher section of roof vil v v OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 7 3 INSTALLATION 3 3 Installing the internal flue Position the single skin flue inside the suspension bracket and tighten the grab screws
6. n the first instance The appliance and flue system must be installed in accordance with AS NZS 2918 and the relevant building code or codes modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS NZS 4013 o the flue has been installed and approved by a professional installer the flue must not be modified in any way OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 3 2 PRE INSTALLATION MINIMUM CLEARANCE INTERNAL 2 1 Clearance from non combustible surfaces 2 3 Clearance from combustible surfaces eg masonry eg timber joist amp plasterboard 100mm minimum clearance is required from fully 1200mm minimum clearance is required on all sides non combustible surfaces when the ErgoFocus can rotate 360 Non Combustible Combustible 100 NE 1200 mM aiqusnqwio FULLY ROTATING ajqusnquio7 uoN 22 f 700mm minimum clearance is required if the rotation of the ErgoFocus is locked at 120 or 90 away from the wall Locking the ErgoFocus so that the opening is fixed 00mm minimum clearance is required from normal Is an option available on purchase non combustible glass 300mm minimum clearance is required from Combustible toughened glass Glass frameless or aluminium frame aiqusnquio m 500 9g e 5 a Clea
7. rances may be reduced with the application of 3 ces heat shielding to walls in accordance to the Australian Building Code PORTANI For information on heat shielding please contact our Frames must also be considered Timber window office on 03 9416 0400 or email info Qoblica com au frames must be treated as combustible surfaces see 2 3 Aluminium frames can be treated as non combustible surfaces see 2 2 OBLICA ERGOFOCUS INSTALLATION AND USER MANUAL PAGE 4 3 INSTALLATION 3 1 Installing the suspension bracket The bracket must be structurally secured within the roof as shown in the diagram below The largest cylinder must project down from the ceiling by at least 150mm BCA requirement unless the ceiling is made from a non combustible material such as concrete You must leave a 25mm clearance gap between the bracket and the ceiling This gap will be covered by the ceiling Flange 12mm ventilation gap between the plasterboard and the ceiling flange 25mm minimum clearance from the triple skin flue to any combustible material within the roof space 40mm minimum overlap of the stainless steel 8 flue into the connector TYPICAL FLAT ROOF INSTALLATION FLAT ROOF INSTALLATION 4 7y CHINAMAN HAT ES RN NE AS lt Anti Down Draft device mew 3 4 TRIPLE SKIN FLUE 200 X 250 X 300 ie 8 x 10 x 127 RUBBER FLASHING a lt Insulativ