Home

Copyright Disclaimer FCC Warning

image

Contents

1. MM Half MM Full Node to Node i 412 meters Node to Switch Node to Node j 2 kilometers Node to Switch Single Mode Converters FT 80xynn x 2 6 y S A B nn km SM Full 0 NOTE Node to Node y Depends on model Node to Switch 1 Consult your local dealer for more about our single mode fiber connectivity 2 A model TX 1310nm RX 1510nm and B model TX 1510nm RX 1310nm should runs in pair Chapter 10 FT 80X Technical Specifications The FT 80X comes with the following standard features Standard IEEE802 3 u 10 100Base TX and 100Base FX Connectors One RJ 45 Auto MDI MDI X Twisted Pair EIA568 gt One Fiber optic 1310nm wavelength except FT 806A FT 806B connector type vary with model Data Transfer Rate 10 100Mbps TP 100Mbps FX Duplex mode support Full or half duplex mode by Auto Negotiation TP LED indicators PWR FX LNK ACT FX FDX COL TP 100 TP LNK ACT TP FDX COL Power Requirement 5V DC 2A Ambient Temperature 0 to 50 C operating Humidity 5 to 90 non condensing Dimension 26 x 70 x 97mm HxWxD Cable UTP Cat 5 UTP cable gt Fiber MM 50 125 um or 62 5 125 um optic fiber gt Fiber SM 8 3 125 8 7 125 9 125 um optic fiber Connecting to Router Bridge or Switch Hub please refer to the device s Technical Manual Chapter 11 Power information The power jack of FT 80X is with 2 5mm in the central post and required 5V
2. Copyright Copyright PLANET Technology Corp 2004 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technol ogy Corp The information in this manual is subject to change without notice All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality per formance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digita
3. DC power input It will conform to the bundled AC DC adapter and Planet s Media Chassis Should you have the problem to make the power connection please contact your local sales representative Please keep the AC DC adapter as spare parts when your FT 80X is installed to a Media Chassis 11 This page is intentionally left blank 2010 000002 005 CE
4. X Technical Specifications 10 Chapter 11 Power information 11 Chapter 1 Overview Thank you for purchasing PLANET FT 80X family 10 100Mbps Ethernet Twisted pair to 100Base FX Fiber optic Bridge Converter This converter is used to convert one type media signal to other type equivalent that allows two type segments connect easily efficiently and inexpensively This converter can be used as a standalone unit or as a slide in module to the 10 19 media chassis up to 15 units for a TP and Fiber combined networks at a central wiring closet Please contact with your sales representative for more about the 19 media chassis Chapter 2 Model List Your Fast Ethernet Converter comes with one of the following models FT 801 on board ST fiber connector gt FT 802 S on board SC fiber connector FT 803 on board MTRJ fiber connector gt FT 806A20 on board single SC fiber connector FT 806B20 on board single SC fiber connector Models with last character S indicate the fiber port is with Single Mode optic fiber connector and followed with a number indicates the maximum wiring distance In the following sections the term FT 80X indicates the product family above Chapter 3 Checklist Your FT 80X carton should contain the following items gt The Fast Ethernet Bridge Converter gt AC DC Power Adapter Output 5VDC 2 A max This user s manual If any item is missing or damaged please con
5. l device pur suant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communica tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Revision User s manual for PLANET Fast Ethernet Converter Multi mode FT 801 FT 802 FT 803 Single mode FT 802S15 FT 802S35 FT 802S50 FT 806A20 FT 806B20 Rev 6 0 September 2004 Part No 2010 000002 005 Table of Contents Chapter 1 Overview 1 Chapter 2 Model List 1 Chapter 3 Checklist 2 Chapter 4 Product Outlook 2 Chapter 5 Link Fault Pass through LFP 3 Chapter 6 Installing the Converter 6 Chapter 7 Duplex Mode setting 7 Chapter 8 LED indication 8 Chapter 9 Cable Connection Parameter 9 Chapter 10 FT 80
6. n and for diagnostic purpose i e check which end is broken you can turn it off and reset the converter to make it take effect Otherwise please remains it in the default position Chapter 6 Installing the Converter Please follow these steps to install the converter Turn off the power of the device station in a network to which the FT 80X will be attached Ensure that there is no activity in the network Attach fiber cable from the FT 80X to the fiber network TX RX must be paired at both ends Attach a Cat 5 UTP cable from the 10 100Base TX net work to the RJ 45 port on the FT 80X Connect the 5VDC power adapter to the FT 80X and verify that the Power LED lights up Turn on the power of the device station the TX Link and FX Link LEDs should light when all cables are attached Turn on the power of the device station the TX Link and FX Link LEDs should light when all cables are attached 10 100Base TX Cat 5 5e TP Cable Network 100Base FX PLAN ET Fiber Network e RJ 45 STP UTP Cat 5 straight crossover cable is accepted 9 NOTE e Please refer to section 8 for more about J6 the wiring distance of your TP Optic fiber networks Chapter 7 Duplex Mode setting The TP port of FT 80X supports duplex mode detection by auto negotiation A N The following is the duplex mode parameters Fast Ethernet Device FT 80X Duplex Mode support Ethernet Fast Ethernet Hub Half Duplex E
7. ss the link the converter s fiber will disconnect the link of transmit Both can immediately alarm administrators the problem of the link media and provide efficient solution to monitor the net Link Loss Carry Forward LLCF FT 80X incorporates an LLCF function for troubleshooting a remote connection When LFP function is enabled the FL TP ports do not transmit a link signal until they receive a link signal from the opposite port The diagram below shows a typical network configuration with a good link status using FT 80X for remote connectivity Management Switch Hub Media Media Switch Hub Management Station w SNMP Converter Converter w SNMP Station hek H 0 o o ne Hr 0 LT LFPON e LED lit established link o LED unlit no link If the connection breaks FT 80X that link loss forward to the switch hub that generates a trap to the management station The administrator can then determine the source of the problem Management Switch Hub Media Media Switch Hub Management Station wiSNMP Converter Converter wSNMP Station E H 0 0 070 0 0 670 Cable e LED lit established link o LED unlit no link Units are shipped with the LFP function enabled ON Link Loss Return LLR The fiber ports of FT 80X have been designed with an LLR function for troubleshooting a remote connection LLR works in conjunction with LLCF When LFP function is enabled by defa
8. sult the dealer from whom you purchased your Fast Ethernet Converter Chapter 4 Product Outlook Right View There are one RJ 45 Twisted Pair jack Auto MDI MDI X one fiber optic connector vary by model and six LED indicators FX TX TX x OOM OS DS Fast Ethernet Bridge PWR 100 10 100Base TX to 100Base FX Left View One DIP switch for Fiber optic operating mode selection FDX for full duplex and HDX for half duplex SvDC cE FX Duplex um Seo Hox Lepx Side View FT 80X One DIP switch for Link Fault Pass Through LFP feature ON to turn on the LLCF and LLR detection And OFF to turn off this feature Please refer to the following sections for more 00000000 LFP 00000000 00000000 OFF ON DIP Switch for LFP function Chapter 5 Link Fault Pass through LFP The LFP function includes the Link Fault Pass Through function LLCF LLR and the DIP Switch design LLCF LLR can immediately alarm administrators the problem of the link media and provide efficient solution to monitor the net The DIP Switch provides disable or enable the LFP function LLCF Link Loss Carry Forward means when a device connected to the converter and the TP line loss the link the converter s fiber will disconnect the link of transmit LLR Link Loss Return means when a device connected to the converter and the fiber line lo
9. thernet Fast Ethernet Switch Half Duplex without A N Fast Ethernet Devices Full Duplex Half Support Auto Negotiation Duplex Normally an A N switch will detect and set to Bo NOTE full duplex where a dual speed hub will detects half There is a DIP switch as in the left view as section 4 Please check and follow the duplex mode of the fiber device and have the duplex selection to your FT 80X Chapter 8 LED indication FX LNK Green Blinks when any FX packets transmit ACT ting and receiving Lit when Fiber connection is good TX LNK Green Blinks when any TP packets transmit ACT ting and receiving Lit when TP connection is good FX FDX Green Lit when Full duplex mode is enabled COL in FX port Blinks indicate that the connection is experiencing collisions TX FDX Green Lit when Full duplex mode is enabled co detect by Auto Negotiation in TP port Blinks indicate that the connection is experiencing collisions L 0 Green Lit when the TP port runs in 100Mbps Remains off while LINK LED lit repre sent the TP port runs in 10Mbps Lit when 5VDC power detected Fiber optic Partner should be set to the cor NOTE rect mode according to this FDX indicator for optimal network performance 10 Ww Chapter 9 Cable Connection Parameter The limitations are as below Duplex Twisted Pair Half Full Node to Node 100 meters Node to Switch Hub Multi Mode Converters
10. ult the port s transmitter shuts down when its receiver fails to detect a valid receive link LLR should only be enabled on one end of the link and is typically enabled on either the unmanaged or remote device The diagram below shows a typical network configuration with a good link status using FT 80X for remote connectivity Note that LLR and LLCF are enabled as indicated in the diagram 4 Station Management Switch Hub Media Media Switch Hub Station wiSNMP Converter Converter Ee gt R 8 ee e LED lit established link _o LED unlit no link 00 005 0000 0 Cable If one of the optical conductors is bad as shown in the diagram box below the converter with LLR function will return a no link condition to its link partner With LLCF function also enabled the no link condition is carried forward to the switch hub where a trap is generated to the management station and the administrator can then determine the source of the loss Station Management Switch Hub Media Media Management Ba gt R ines aa 4 gt e LED lit established link o LED unlit no link wiSNMP Converter Converter Switch Hub Station e O OO O A Port 2 N Fiber Jl Port 1 A Link Loss Caned Forvard Lin Lose Cared Foward Link Loss Returned NOTE LFP function is turn on in default This feature can also be turned off via the side DIP switch If you are familiar with the network installatio

Download Pdf Manuals

image

Related Search

Related Contents

DOMINO-1™  MPPT Solar charger ISC3042 Manual  Recomendaciones Redes Inalámbricas..rtf  Novosoft Mobile Instant Messenger  Istruzioni per l`uso Frigo Manual de instrucciones Frigorífico  Hanns.G HE195ABB    iconManual  

Copyright © All rights reserved.