Home
12KX User Guide
Contents
1. Figure 2 1 12KX PoE switch 2 LED display elements 3 USB interface 4 V 24 connection for external management 5 4 x Gigabit ETHERNET combo ports with Power over Ethernet PoE 100 1000 Mbit s fiber optic SFP slots Alternative connections 10 100 1000 Mbit s twisted pair RJ45 connections 6 4 x Gigabit ETHERNET combo ports 100 1000 Mbit s fiber optic SFP slots Alternative connections 10 100 1000 Mbit s twisted pair RJ45 connections Back of device 7 P1 Connection for the voltage supply 8 Relay 1 signal contact Back of device for device variants with 2 power supply units 9 P2 Connection for the PoE voltage supply 10 Relay 2 signal contact 16 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 3 3 12KXR 2H 12KXR 2L 12KXR 1H 12KXR 1L with 16 Gigabit ports ports on rear Figure 3 Back of device 1 12KXR switch 2 LED display elements 3 USB interface 4 V 24 connection for external management 5 4 x Gigabit ETHERNET combo ports 100 1000 Mbit s fiber optic SFP slots Alternative connections 10 100 1000 Mbit s twisted pair RJ45 connections 6 P1 Connection for the voltage supply 7 Relay 1 signal contact For device variants with 2 power supply units 8 P2 Connection for redundant voltage supply 9 Relay 2 signal contact Front of device 10 LED device status display elements 11 LED port status display elements 12 LED service por
2. 1 This device may not cause harmful interference 2 this device must accept any interference received including interference that may cause undesired operation Magnum 12KX Managed Switch Installation and User Guide 09 11 Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can radiate same and if it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a living area can also cause interference and in this case the user is obliged to cover the costs of removing the interference Recycling note After usage this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state and country e RoHS compliant Magnum 12KX Managed Switch Installation and User Guide 09 11 About this Manual The Installation user manual contains a device description safety instructions a description of the display and the other information that you need to install the device The MNS 12KS L2 software provides you with additional options for smooth configuration and monitoring Event log Configuration of Sy
3. Fremont CA 94539 7437 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com Email GCI support garrettcom com i Magnum 12KX Managed Switch Installation and User Guide 09 11 Table of Contents Page Safety instructions sccsscscsscssecssssessssssssscesssssesssssssssssseescsssesessssssesssssessesseees 1 About this Manntal scssccssssssscssssssssssssssssssnessssnscsssssesssssssssssnessessessossessosees 7 1 0 Introduction eesccsecscescssseecesencsscssescesssssescsssnessssesssesssenessessessoseoses 8 1 1 Ordering Information ee eeeeecesecceeeeeeeeeeceeeeeceaeeeeeaecaeeeesneeereeaeeneeaeeas 9 1 2 Product Description ecceeccesceesecesececeeseeeseeeeeeeeeeeeeeeenaeeneenaeenseenaes 12 1 3 Description of model variants ccessseseceeeeeenseeeceseceeeeeeeeereeeeeeeres 14 1 3 1 12KX 2H 12KX 2L 12K X 1H 12K X 1D e 15 1 3 2 12KX 1H1IPOE 12K X 1LIPOE ec eceeceeeereeceeeceeeeeeeeeeeeeeeenes 16 1 3 3 12K XR 2H 12K XR 2L 12K XR 1H 12K XR 1L eee 17 1 3 4 12K XR 1HI1POE 12K XR 1ILIPOE ee eeceeseeseeeeneeseeeeneeaeeeenes 18 1 3 5 POE POtts srci eaeoe E E aE E AEAEE ENS 19 1 3 6 COMPO POMS esaeraren enr E A E ETE RES 19 2 0 Installation and Set up se eeseesesoossesoossesessoesesoossesoessesessoesesosssessessssessosses 20 2 1 Tostal ation di upiarin eyi e pipet Ea pree ea E aE o EREET 20 2 1 1 Unpacking and checking 0 cceccececsseesceeceeeceeseeeeeeeeeneeneesaeenaes 20 2 1
4. MM ports Note 2 When the SFP port is used the RJ45 copper port is disabled _www GarettCom con ss 29 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 Gbit s fiber optic connection 1 GBit s fiber optic ports SFP slot enable the connection of terminal devices or independent network segments in compliance with the IEEE 802 3 2000 ISO IEC 8802 3 2000 1000BASE SX or 1000BASE LX standards When the SFP port is used the RJ45 copper port is disabled These ports support e Auto negotiation e Full duplex mode Default settings auto negotiation Note Make sure that the LH ports are only connected with LH ports SX ports are only connected with SX ports and LX ports only with LX ports 2 2 Display elements After the operating voltage is set up the software starts and initializes itself Afterwards the device performs a self test During this process various LEDs light up The process takes around 15 seconds Figure 12 Display elements for 12KX and 12KX PoE front mount 1 Device status display elements 2 Port status display elements Figure 13 Display elements for 12KXR and 12KXR PoE reverse mount Front of device 1 Device status display elements 2 Port status display elements for 16 Gigabit ETHERNET ports 3 Diagnosis port with display element Back of device 4 Device status display elements 5 Port status display elements www GarrettCom com ss ss 30 Magnum 12KX Managed Switc
5. Warning N If the neutral conductor or the negative terminal of the supply voltage is not grounded If you are using a DC voltage greater than 125 VDC for the supply voltage install a suitable input fuse For power supply units with product code H use a slow blow fuse with a nominal rating of 2 5 A for the voltage supply input For power supply units with product code L use a slow blow fuse with a nominal rating of 6 3 A With AC power supply use a cable cross section of at least 0 75 mm North America AWG 18 for the current conductor at the voltage input With DC power supply use a cable cross section of at least 1 0 mm North America AWG 16 for the current conductor at the voltage input e Relevant for North America Only use copper wire conductors of class 1 60 75 C or 75 C Warning Only connect a supply voltage that corresponds to the type plate of your device Power supply type L 18 to 60 V DC Power unit type H 77 to 300 V DC or 90 to 265 V AC Shielding ground The shielding ground of the connectable twisted pairs lines is connected to the front panel as a conductor e Beware of possible short circuits when connecting a cable section with conductive shielding braiding Housing Only technicians authorized by the manufacturer are permitted to open the housing The device is grounded via a ground connection on the front panel of the device e Make sure that the electrical insta
6. all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 41 Magnum 12KX Managed Switch Installation and User Guide 09 11 4 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATIO
7. cat5e cable with 1 OOOBASE T Table 4 TP port 1OBASE T 1OOBASE TX 1OOOBASE T Model Wave Fiber System Distance Fiber Data SFP length Attenuation 12KX FXMM2 MM 50 125 um 0 8 dB 0 5 km 1 0 dB km 1310nm 800 MHz km FXMM2 MM 62 5 125 um 0 11 dB 0 4 km 1 0 dB km 1310nm 500 MHz km FXSM25 SM 9 125 um 0 13 dB 0 25 km 0 4 dB km 1310nm 3 5 ps am km FXSM100 SM 9 125 um 10 29 dB 40 104 km 0 25 dB km 1550nm 19 ps nm km Table 5 Fiber port 1OOBASE FX SFP fiber optic Fast ETHERNET Transceiver 37 Magnum 12KX Managed Switch Installation and User Guide 09 11 Model Wave Fiber System Distance Fiber Data SFP length Attenuation 12KX SX MM 50 125 um 0 7 5 dB 0 5 km 3 0 dB km 850nm 400 MHz km SX MM 62 5 125 um 0 7 5 dB 0 4 km 3 2 dB km 850nm 200 MHz km LX25 SM 9 125 um 0 11 dB 0 20 km 0 4 dB km 1310nm 3 5 ps am km ZX40 SM 9 125 um 5 20 dB 14 42 km 0 4 dB km 1550nm 3 5 ps am km ZX70 SM 9 125 um 6 22 dB 24 72 km 0 25 dB km 1550nm 19 ps nm km Table 6 Fiber port 1OOOBASE FX SFP fiber optic Gigabit ETHERNET Transceiver MM Multimode SM Singlemode Power consumption power output Models without PoE Maximum power Maximum 12KX 12KXR consumption power output Device without SFP modules without TP links 10 W 34 Btu IT h additionally for each connected SFP module 1W 3 Btu T h additionally for each TP por
8. models without PoE For models with two power units if there is non redundant voltage supply the device reports the failure of one supply voltage You can prevent this message by applying the supply voltage via both inputs or by changing the configuration in the Management Magnum 12KX models with PoE Magnum 12KX models with PoE Power over Ethernet are equipped with two power units e Power unit 2 is a PoE power unit see ordering information starting on page 9 e You can choose the connections to power unit 1 see ordering information starting on page 9 21 Magnum 12KX Managed Switch Installation and User Guide 09 11 Connecting the supply voltage Warning Never insert sharp objects small screwdrivers wires etc into the terminal block for the supply voltage and do not touch the A terminals There is the risk of an electric shock Note Note the safety instructions see on page 1 Supply voltage and only connect a supply voltage that corresponds to the type plate of your device Make sure that the contact load capability of the signal contact is not exceeded see on page 36 Technical data Note Relevant for North America The tightening torque of the terminal block screws is 3 1b in 0 34 Nm e Pull the terminal block s off the switch and connect the voltage supply lines as follows e First connect the protective conductor to the protective conductor terminal e Connect the supply voltage via the 3 p
9. module E Push the SFP module with the lock closed into the socket until it latches audibly in place Note Only use GarrettCom SFP modules see pages 10 11 20 Magnum 12KX Managed Switch Installation and User Guide 09 11 2 1 3 Connecting the power unit connections for supply voltage and signal contact Connect the power supply and signal lines Note Note the safety instructions see on page 1 Supply voltage and only connect a supply voltage that corresponds to the type plate of your device Make sure that the contact load capability of the signal contact is not exceeded see on page 36 Technical data The voltage supply is connected via a 3 pin terminal block with screw locking The signal contact is connected via a 2 pin terminal block with screw locking 1 or 2 locks depending on the device design For device variants without PoE The supply voltage in 12K X and reverse mount 12K XR device types can be connected redundantly with two power units Both inputs are uncoupled The supply voltage is electrically isolated from the housing Magnum 12KX models without PoE Magnum 12KX models without PoE Power over Ethernet are depending on the device type equipped with one or two power units of the following type e Type L 18 VDC to 60 VDC see ordering information starting on page 9 and or e Type H 77 VDC to 300 VDC or 90 VAC to 265 VAC see ordering information starting on page 9 Note For
10. 2 Installing the SFP modules optional eeeeeseeseeseeneeeeeeeeees 20 2 1 3 Connecting the power unit connections for supply voltage and signal CONACE eeecesecseeseeeseeseeeeeeeseeeeeeeceeeesecesecaecesesseecaeeeseeees 21 2 1 4 Installing the device and grounding ceeeeeeeeeeneeeeeeeeeeeeeeenees 24 2 1 5 Startup procedure cecceccesseeccessceesceereeeeceeeceseceaecseecseecseeseeeneeses 28 2 1 6 Connecting the data Lines ee eeeeeseeeseceeeeeceeeerceeeeeeeeceaeeneeaeeaees 28 2 2 Display elements wis csscieniiienn nian dain dais RE 30 2 3 Basic Set Upss iii diester E rR unas sani dane e 33 3 0 Technical Specifications csscsscscccssccsssccsscssscssscsssccsscessceseseseeees 35 4 0 Troubleshooting sssssssscssscsscsscescsssesssssscssssneesesssssesssssnesssssesseseers 40 4 1 Before Calling for Assistance ccccccescesceeseceseceseceeeceeeseeeeeaeeeneeees 40 4 2 When Calling for Assistance ce eeeeeeseseseseceeeeecnseeeeeeeeeercaeeeeeaeenees 41 4 3 Return Material Authorization RMA Procedure eccceseeereeseees 41 4 4 Shipping and Packaging Information s seesseeseeseeseeesseeeesseserserseesee 42 APPENDIX A WARRANTY INFORMATION ccssssssssssssssesssssssessserseees 42 Revisions Rey A 09 11 Initial Release Magnum 12KX Managed Switch Installation and User Guide 09 11 Safety instructions This documentation contains instructions which must be observed to en
11. 2KX Managed Switch Installation and User Guide 3 0 Technical Specifications m General technical specifications 09 11 Dimensions without 17 6 x 1 7 x 13 6 in WxDxH brackets 448 x 44 x 345 mm Weight 12KX 12KXR max 9 3 lbs 4 2 kg single power supply 12KX 12KXR max 9 7 lbs 4 4 kg dual power supply 12KX 12KXR max 10 1 lbs 4 6 kg single PoE power supply Power Supply unit Nominal voltage AC 100 240 V 50 60 Hz type H Voltage range AC 90 265 V 47 63 Hz Nominal voltage DC 110 250 V Voltage range DC 71 300 V Connection type 3 pin terminal block Power failure bridging gt 20 ms at 230 V AC Fuse Built into the power unit Power Supply unit Nominal voltage DC 24 48 V type L Voltage range DC 18 60 V Connection type Power failure bridging Fuse 3 pin terminal block gt 10 ms at 20 4 V DC Built into the power unit Signal contact Nominal value for AC Nominal value for DC Connection type 2 A at 230 V AC 500 VA 2 A at 30 V DC 0 2 A at 125 V DC 0 1 A at 250 V DC 2 pin terminal block Environment Storage temperature Standard 40 C to 70 C ambient air Extended 40 C to 85 C Humidity 5 to 95 non condensing Air pressure Up to 2000 m 795 hPa Operating temperature Extended surrounding air 40 C to 85 C Pollution degree 2 Protection classes Laser protection Class 1 according to EN 60825 1 2001 Protection class IP 30
12. 35 Magnum 12KX Managed Switch Installation and User Guide EMC and immunity 09 11 EMC interference Description Test level immunity IEC EN 61850 3 2002 EMI TYPE tests test in comp with IEC EN 61000 4 2 Electrostatic discharge Contact discharge 8 kV Air discharge 15 kV IEC EN 61000 4 3 Electromagnetic field 80 2 700 MHz 20 V m IEC EN 61000 4 4 Fast transients burst DC power line AC power line Data line 4 KV 2 5 kHz 4 KV 2 5 kHz 4 KV 2 5 kHz IEC EN 61000 4 5 Voltage surges DC power line AC power line 2 kV line earth 1 kV line line 4 kV line earth 2 kV line line Data line 4 kV line earth IEC EN 61000 4 6 Line conducted interference voltages 10 V 150 kHz 80 MHz IEC EN 61000 4 12 Damped vibration DC power line AC power line Data line 2 5kV line earth 1kV line line 2 5kV line earth 1kV line line 2 5kV line earth 1kV line line IEC 60255 5 Dielectric strength DC power line power unit type L 500 VAC AC power line power unit type H 2000 VAC DC power line power unit type H 2000 VAC Signal contact type L and H 2000 VAC EMC interference Description Test level immunity IEEE 1613 2009 EMI TYPE tests test in comp with IEEE C37 90 3 Electrostatic discharge Contact discharge 4 8kV Air discharge 15kV IEEE C37 90 2 Electromagnetic field 80 1 000MHz 35 V m peak IEEE C
13. 37 90 1 Fast transients burst DC power line AC power line Data line 4 kV 2 5 kHz 4 kV 2 5 kHz 4 kV 2 5 kHz IEEE C37 90 1 Damped vibration DC power line AC power line Data line 2 5kV line earth 2 5kV line earth 2 5kV line earth 1kV line line 1kV line line 1kV line line 36 Magnum 12KX Managed Switch Installation and User Guide 09 11 EMC interference Description Test level immunity IEEE 1613 2009 EMI TYPE tests test in comp with IEEE C37 90 H V impulse DC power line 5 kV line earth AC power line 5 kV line earth IEEE C37 90 Dielectric strength DC power line power unit type L 500 VAC AC power line power unit type H 2000 VAC DC power line power unit type H 2000 VAC Signal contact type L and H 2000 VAC EMC emitted interference EN 55022 Class A FCC 47 CFR Part 15 Class A German Lloyd Classification Construction Guidelines VI 7 3 Part 1 Ed 2001 Environment type Description Test level tests test in comp with IEC 60068 2 1 Cold 40 C 16 hours IEC 60068 2 2 Dry heat 85 C 16 hours IEC 60068 2 30 Relative humidity 95 non condensing IEC 60068 2 6 IEC 60068 2 27 Vibration test Fc Shock test Ea 55 C 4 cycles 2 9 Hz with 3 mm amplitude 1 gat9 150 Hz 1 5 g at 200 500 Hz 15 g at 11 ms Network range TP port Length of a twisted pair segment max 100 m 328 ft
14. Gigabit ETHERNET SFP modules see pages 10 11 SFP stands for Small Form factor Pluggable and is also frequently referred to as mini GBIC GigaBit Interface Converter The SFP modules are plugged into the SFP slots of the Magnum 12KX device in order to obtain an F O port The 12K X has 16 TP interfaces and 16 slots for inserting SFP modules 100 1000 Mbit s By inserting the SFP module you deactivate the corresponding TP interface Note Only use GarrettCom SFP modules see pages 10 11 www GarrettCom com 19 Magnum 12KX Managed Switch Installation and User Guide 09 11 2 0 Installation and Set up The devices have been developed for use in Substations The installation process is correspondingly simple On delivery the device is ready for operation The following procedure has been proven to be successful for the installation of the device e Unpacking and checking e Installing the SFP modules optional e Connecting the power unit connections for supply voltage and signal contact e Installing the device and grounding e Startup e Connecting the data lines 2 1 Installation 2 1 1 Unpacking and checking e Check that the contents of the package are complete Magnum 12KX unit 2x brackets Connectors for power supply and relay contact e Check the individual parts for transport damage 2 1 2 Installing the SFP modules optional Figure 5 Fast ETHERNET 100Mb fiber optic SFP module or Gigabit ETHERNET fiber optic SFP
15. N GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of five 5 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty 42
16. Oo GarrettCom Industrial Networking at Its Best Magnum 12KX Substation Hardened Gigabit Switch w 1588v2 Timing Hardware Installation and User Guide Magnum 12KX Managed Switch Installation and User Guide 09 11 Magnum 12KX Managed Switch Hardware Installation and User Guide Part 84 00189Z Rev A Trademarks GarrettCom is a registered trademark and Magnum Dymec DynaStar Personal Switch Link Loss Learn S Ring Convenient Switch and Converter Switch are trademarks of GarrettCom Inc Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum 12KX Managed Switch contains no user serviceable parts Attempted service by unauthorized personnel may render all warranties null and void If problems are experienced with Magnum 12KX Switch products contact your supplier for assistance or contact GarrettCom Customer Support Copyright 2011 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr
17. PoE Power Supply for 4 PoE ports MODEL DESCRIPTION Magnum 12KX 1H1POE Magnum 12KX PoE Managed L2 or L3 Switch front mount with one ACDC high internal Power Supply for the switch and one ACDC high power supply for powering four RJ45 PoE ports Twelve other Gb ports each of which are combo auto negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing Heavy duty case convection cooled Includes RJ11 console port plus a USB interface for auto configuration and saving and an alarm contact for signaling power loss Choose either Layer 2 software default or optional Layer 3 software factory installed Magnum 12KXR 1H1POE Same as Model 12K X 1H1POE except chassis is a Reverse Mount unit All signal and power cables are in the rear Magnum 12KX 1L1POE Magnum 12KX PoE Managed L2 or L3 Switch front mount with one 24V to 48V nominal low DC internal Power Supply for the switch and and one ACDC high power supply for powering four RJ45 PoE ports Twelve other Gb ports each of which are combo auto negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing Heavy duty case convection cooled Includes RJ11 console port plus a USB interface for auto configuration and saving and an alarm contact for signaling power loss Choose either Layer 2 software default or optional Layer 3 software factory installed Magnum 12KXR 1L1POE Same as Model 12KX 1L1POE e
18. TP ports enable the connection of terminal devices or independent network segments according to the IEEE 802 3 10BASE T 100BASE TX 1000BASE T standard The Magnum 12KX PoE and reverse mount 12K XR PoE also allow IEEE 802 3af Power over ETHERNET on data lines These ports support Auto negotiation Auto polarity Auto crossing if auto negotiation is activated 1000 Mbit s full duplex 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Also for Magnum 12KX PoE and reverse mount 12K XR PoE Power over ETHERNET PoE at the first four ports of the device The PoE voltage is input via the wire pairs transmitting the signal phantom voltage Default setting auto negotiation activated The socket housing is electrically connected to the front panel The pin assignment corresponds to MDI X 28 Magnum 12KX Managed Switch Installation and User Guide 09 11 3 Pin Function PoE 6 T 1 DB V oOo q 2 DB V 3 3 DA V 1 4 DD 5 DD Table 2 Pin assignment of a 1000 6 DA V MBit s TP interface in MDI X mode RJ45 socket for PoE with the power 7 DC supplied via the wire pairs transmitting 8 DC the signal Note In substation applications the RJ45 ports are used to connect to additional communication devices such as routers or telecommunication multiplexers tha
19. arrettCom com ss lt ss 33 Magnum 12KX Managed Switch Installation and User Guide 09 11 USB interface The USB socket has an interface for the local connection of an Auto Configuration Adapter part number ACA21 USB 12KX see on page 11 It is used for saving loading the configuration and for loading the software Pin Function Jam 1 VCC VBus 7 a 2 Data 1234 3 Data 4 Ground GND Table 3 Pin assignment of the USB interface 6 1 V 24 interface external management The V 24 interface is an RJ11 socket At the V 24 connection a serial interface is provided for the local connection of an external management station VT 100 terminal or PC with corresponding terminal emulation This enables you to set up a connection to the Command Line Interface CLI and to the system monitor VT 100 terminal settings Speed 9 600 Baud Data 8 bit Stopbit 1 bit Handshake Off Parity none The socket housing is electrically connected to the front panel of the device The V 24 interface is not electrically isolated from the supply voltage RJ11 DB9 RJ11 DB9 paa m X r 7 o 5 CTS 1 o2 nc 2 eee 2 29 co ilS o 1 RX 5 5 RTS 6 Figure 14 Pin assignment of the V 24 interface and the DB9 connector Note You will find the order number for the terminal cable which is ordered separately in the Ordering information section pn CONSOLE CBL 12KX see page 11 34 Magnum 1
20. bilities available in the software Upholding GarretCom s product line of time tested robust products the switch is designed for heavy duty industrial applications in harsh environments with a temperature rating of 40 C to 85 C Additionally the unit is convection cooled no fans has a redundant power supply is vibration resistant ESD immune and is available with optional conformal coating Layer 3 software for the Magnum 12KX includes full wire speed IPv4 RIP based routing port based routing interfaces static routing VLAN based router interface definitions double VLAN tagging protocol based VLANs Multicast Routing DVMRP IGMPv1 v2 v3 Multicast routing and IGMP Unknown Multicast Filtering simultaneously PIM DM Alternately environments using OSPF can use OSPF v2 capabilities included in the software The GarrettCom Magnum 12K X Gigabit managed switch along with the Magnum 10KT managed switch and Magnum 10ETS managed terminal server allow network architects to create networks encompassing features such as precision time synchronization high availability Layer 2 as well as Layer 3 devices serial and Ethernet connectivity routing flexibility such as RIP or OSPF and more For networks that do not need the Layer 3 software capability the Magnum 12KX Gigabit managed switch is available with Layer 2 software offering simplicity and affordability Magnum 12KX Managed Switch Installation and User Guide 09 11 1 1 Ordering Informat
21. ck of the device The device has 16 Gigabit ETHERNET ports and an additional Fast ETHERNET port on the front of the device that you can use for diagnosis purposes 1 3 5 PoE ports The Magnum 12KX PoE and reverse mount 12K XR PoE models support Power over Ethernet PoE in accordance with IEEE 802 3af on ports 1 to 4 They allow the connection and remote supply of for example IP telephones Voice over IP webcams sensors printer servers and WLAN access points via 10BASE T 100BASE TX 1000BASE T With PoE these terminal devices are powered by the twisted pair cable The 12KX PoE and 12KXR PoE provide four 1 OBASE T 100BASE TX 1000BASE T ports RJ45 sockets for connecting network segments or PoE terminal devices PD Powered Device for all IEEE802 3af classes up to a maximum power output of 15 4 W The 4 PoE capable ports are the 4 first ports on the device ports 1 to 4 see fig 2 and fig 4 The current is supplied on wire pairs transmitting the signal pins 1 2 3 amp 6 The individual ports are not electrically insulated from each other see page 28 10 100 1000 Mbit s twisted pair connection The following conditions are met in accordance with IEEE 802 3af e Endpoint PSE e Alternative A 1 3 6 Combo ports At the four Gigabit ETHERNET combo ports see fig 1 to fig 4 you can connect either F O via SFP modules or twisted pair port via RJ45 m SFP modules SFP modules are optical transceivers Fast ETHERNET and
22. contact GarrettCom Customer Support 4 1 Before Calling for Assistance l If difficulty is encountered when installing or operating the unit refer back to the Installation and Set up section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that power is properly attached to each Magnum 12KX Switch unit Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolated to a network device other than the Magnum 12KX Switch product it is recommended that the problem device be replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum 12K X Switch and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum 12KX Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 40 Magnum 12KX Managed Switch Installation and User Guide 09 11 4 2 When Calling for Assistance Please be prepared to provide the following information l A complete descrip
23. d error during the self test e Permitted temperature range exceeded not reached Note You can use the signal contact functions when the voltage supply is connected If there is redundant voltage supply but this is turned off there is a contact interruption at the corresponding signal contact 2 1 4 Installing the device and grounding Note The shielding ground of the connectable industrial twisted pair lines is connected to the front panel as a conductor Mounting in a 19 rack The devices are designed to be mounted in a 19 rack e Make sure there is sufficient ventilation If necessary provide a fan for the 19 rack This will prevent the basic devices from overheating e Measure the depth of the 19 rack so as to allow the main cable and any power supply cables to be fitted from the back and the data cables to be fitted from the front 24 Magnum 12KX Managed Switch Installation and User Guide 09 11 33 462 6 4 38 osf 17 38 0 13 fe F bk sooo BGSE ECC BEE gs oa o jess Li el el el e AT mi raah Coco rah roon inch oO N il 19 3 L 444 193 0 76 17 48 0 76 Figure 8 Dimensions mm inch If you are operating the device in a 19 switch cabinet mounting brackets are used included in the delivery to hold the weight of the device Warning A If the de
24. d of the connectable industrial twisted pair lines is connected to the front panel as a conductor 26 Magnum 12KX Managed Switch Installation and User Guide 09 11 olv 5 ae 2 3 inc ge i RCR SECRECSSEJS as J 3 3 462 6 3 3 0 13 17 38 0 13 dah Coch MEE mgo i alo o te Ke NM E a5 tO Ol N hie ro mt lo o 19 3 444 19 3 0 76 17 48 0 76 Figure 10 Dimensions mm inch Figure 11 Vertical mounting on the wall 27 Magnum 12KX Managed Switch Installation and User Guide 09 11 m Grounding the device The device is grounded via a ground connection on the front panel of the device e Connect the protective conductor before you set up the other connections When removing the connections you remove the protective conductor last e Connect both protective conductors if your device is equipped with two power supply units 2 1 5 Startup procedure When you connect the supply voltage you start up the device 2 1 6 Connecting the data lines You can connect terminal devices and other segments at the ports of the device via twisted pair cables or F O cables e Install the data lines according to your requirements 10 100 1000 Mbit s twisted pair connection These connections are via RJ45 sockets 10 100 1000 Mbit s
25. e00e0 e pmm 2 4 2 4 6 8 10 12 14 16 ETHERNET Service Port 12KX 12KX PoE 12KXR 12KXR PoE 12KXR 12KXR PoE The green and yellow LEDs at the individual port display port related information During the boot phase these LEDs are used to display the status of the boot procedure LS DA link status data one green yellow LED or one green and one yellow LED per port Not glowing No valid connection Glowing green Valid connection Flashing green 1 time a period Port is switched to stand by Flashing green 3 times a period Port is switched off Flashing yellow Receive data send data 2 3 Basic set up The IP parameters must be entered when the device is installed for the first time The device provides 6 options for configuring IP addresses e Entry via V 24 connection Configuration via BOOTP Configuration via DHCP Configuration via DHCP Option 82 Auto Configuration Adapter Default settings e IP address The device looks for the IP address using DHCP e Password for management Login user password public read only Login manager password manager read and write e Parameters that can be set via the management are set to pre defined values in accordance with the MIB e V 24 data rate 9 600 Baud see next page for additional V 24 settings e Ethernet ports link status is not evaluated signal contact e Optical 100 Mbit s ports 100 Mbit s full duplex All other ports auto negotiation www G
26. er Supply MODEL DESCRIPTION Magnum 12KX 1H Magnum 12KX Managed L2 or L3 Switch front mount with one ACDC high internal Power Supply Sixteen Gb ports each of which are combo auto negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing Heavy duty case convection cooled Includes RJ11 console port plus a USB interface for auto configuration and saving and an alarm contact for signaling power loss Choose either Layer 2 software default or optional Layer 3 software factory installed Magnum 12KXR 1H Same as Model 12K X 1H except chassis is a Reverse Mount unit All signal and power cables are in the rear Magnum 12KX 1L Magnum 12KX Managed L2 or L3 Switch front mount with one 24V to 48V nominal low DC internal Power Supply Sixteen Gb ports each of which are combo auto negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing Heavy duty case convection cooled Includes RJ11 console port plus a USB interface for auto configuration and saving and an alarm contact for signaling power loss Choose either Layer 2 software default or optional Layer 3 software factory installed Magnum 12KXR 1L Same as Model 12K X 2L except chassis is a Reverse Mount unit All signal and power cables are in the rear Magnum 12KX Managed Switch Installation and User Guide 09 11 MAGNUM 12KX Switches models with one internal PS for the switch and one internal
27. h Installation and User Guide 09 11 Device state FAULT P RM Stand by om 00 Sb OR 0 o or R1 R2 FAULT P 12KXR 12KXR PoE 12KX 12KX PoE front mount reverse mount 12KXR 12KXR PoE reverse mount These LEDs provide information about conditions which affect the operation of the whole device P Power green yellow LED Glowing green Models with 2 power supply units Both supply voltages are ON Models with 1 power supply unit Supply voltage is ON Glowing yellow Models with dual power supply units There is only one supply voltage P1 or P2 ON Not glowing Supply voltage is too low or not connected Sb Stand By stand by mode green LED Glowing green Stand by mode enabled Not glowing No stand by mode RM and Stand by display saving processes of the Auto Configuration Adapter ACA Flashing alternately Error during saving process LEDs flash Loading configuration from the ACA synchronously two times a second LEDs flash Saving the configuration in the ACA synchronously once a second 31 Magnum 12KX Managed Switch Installation and User Guide 09 11 Applies to software releases previous to 06 0 00 LED Display Color Activity Meaning FAULT Signal contact1 Red Lights up The signal contact is open it is reporting an error None Signal contact is closed it is not reporting an error Applies to software release 06 0 00 and higher LED Display C
28. he devices are PoE capable For devices without PoE the voltage supply can be redundant if required Mount the devices by e 19 switch cabinet e Flat surface mounting You can choose various media to connect terminal devices and other infrastructure components e twisted pair cable e multimode F O e singlemode F O The twisted pair ports support e Auto crossing e Auto negotiation e Auto polarity Magnum 12KX Managed Switch Installation and User Guide 09 11 There are a number of convenient options for managing the device Administer your devices via e a Web browser e Telnet or ssh for Layer 3 e management software e g MNS 12KS e a V 24 interface locally on the Switch Depending on the software you choose the 12K X switch provides you with a large range of functions e Redundancy functions e Rapid Spanning Tree Protocol RSTP e Redundant coupling e Link aggregation e For devices without PoE Redundant power supply Protection from unauthorized access Routing Synchronized system time in the network Network load control Operation diagnosis Diagnostics hardware self testing Reset Priority VLAN Topology Discovery Web based Interface Command Line Interface CLI SNMP 802 1x port authentication IEEE 1588v1 and v2 SNTP time synchronization other features described on page 11 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 3 Description of model variants The models d
29. iffer with regard to the range of software functions the number of interfaces and the media type for connecting segments e The Magnum 12KX devices are Substation hardened Switches with 16 Gigabit combo ETHERNET ports 10 100 1000 Mbit s can be connected optically or with TX These ports are suitable for the connection of terminal devices or network segments according to the standards IEEE 802 3 100 1000BASE FX SFP slot and IEEE 802 3 1000BASE T 100BASE TX 1OBASE T RJ45 socket A plugged SFP module switches the TX port off Reverse mount switches such as 12K XR 2H have an additional V 24 port on the front of the device that you can use for diagnosis and configuration purposes e The PoE devices support PoE Power over Ethernet in accordance with IEEE 802 3af The PoE ports are the Gigabit ETHERNET ports 1 to 4 e The Reverse mount devices all the cable outlets are at the back i e the ports are on the back of the device The devices also provide you with the following options for selecting the variant you desire Voltage range Power unit 1 and optional power unit 2 e 18 V DC to 60 V DC e 77 V DC to 300 V DC e 90V AC to 265 V AC The voltage supply connection is clampable In devices with PoE power supply unit 2 is the PoE power supply unit You can choose the connections to power supply unit 1 Software variant Layer 2 Professional default Layer 3 Professional optional The devices comply with the specification
30. in terminal block Pay attention to the L and N connections e Ifthe neutral conductor or the minus terminal of the supply voltage is not grounded install a suitable fuse in the input line Figure 6 Device with power unit L DC voltage 18 60 VDC 1 Supply voltage 2 Signal contact Figure 7a Devices with power unit H DC voltage 77 300 VDC 1 Supply voltage 2 Signal contact 3 External fuse for supply voltages gt 125 VDC 22 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 2 Relay O ENHL ad o Bi ga Figure 7b Devices with power unit H AC voltage 1 Supply voltage 2 Signal contact Connection Type L Type H VDC Type H VAC inl Protective Protective Protective ape conductor conductor conductor N pin 2 Minus terminal of Minus terminal of Neutral conductor the supply voltage the supply voltage L pin 3 Plus terminal of the Plus terminal of the Phase supply supply voltage supply voltage voltage Table 1 Pin assignment of spring loaded terminal for voltage supply For type H power units you can choose between connecting DC or AC voltage e For supply voltages gt 125 VDC Install a suitable external fuse in the supply voltage input line of the plus terminal see fig 7a No
31. ion Magnum 12KX Switches models with Dual Internal Power Supplies MODEL DESCRIPTION Magnum 12KX 2H Magnum 12KX Managed L2 or L3 Switch front mount with two ACDC high internal Power Supplies for redundancy Sixteen Gb ports each of which are combo auto negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing Heavy duty case convection cooled Includes RJ11 console port plus a USB interface for auto configuration and saving and an alarm contact for signaling power loss Choose either Layer 2 software default or optional Layer 3 software factory installed Magnum 12KXR 2H Same as Model 12KX 2H except chassis is a Reverse Mount unit All signal and power cables are in the rear Magnum 12KX 2L Magnum 12KX Managed L2 or L3 Switch front mount with two 24V to 48V nominal low DC internal Power Supplies for redundancy Sixteen Gb ports each of which are combo auto negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing Heavy duty case convection cooled Includes RJ11 console port plus a USB interface for auto configuration and saving and an alarm contact for signaling power loss Choose either Layer 2 software default or optional Layer 3 software factory installed Magnum 12KXR 2L Same as Model 12K X 2L except chassis is a Reverse Mount unit All signal and power cables are in the rear Magnum 12KX Switches models with one Internal Pow
32. ion Networking Devices in Electric Power Substations Table 7 List of norms and standards Name IEEE 802 1 D Switching GARP GMRP Spanning Tree IEEE 802 1 D 1998 Media access control MAC bridges includes IEEE 802 1p Priority and Dynamic Multicast Filtering GARP GMRP IEEE 802 1 Q Tagging IEEE 802 1 Q 1998 Virtual Bridged Local Area Networks VLAN Tagging GVRP IEEE 802 1 w 2001 Rapid Reconfiguration IEEE 802 3 2002 Ethernet Table 8 List of IEEE standards The device has a certification based on a specific standard only if the certification indicator appears on the housing 39 Magnum 12KX Managed Switch Installation and User Guide 09 11 4 0 Troubleshooting All Magnum products are designed to provide reliability and consistently high performance in all industrial network environments The installation of a Magnum 12KX Switch is a straight forward procedure The operation is also straightforward and is discussed in Section 2 0 of this User Guide Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 12KX Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or
33. llation meets local or nationally applicable safety regulations e The ventilation slots must not be covered so as to ensure free air circulation e The clearance to the ventilation slots of the housing must be at least 10 cm 3 94 in e Do not touch the housing during operation or shortly after switching off the device Hot surfaces can cause injury _www GarrettCom con ss 2 Magnum 12KX Managed Switch Installation and User Guide 09 11 Warning N Never insert sharp objects small screwdrivers wires etc into the inside of the product There is the risk of an electric shock e The device must be installed in the horizontal or upright position either in the switch cabinet or on the wall see on page 24 Installing the device and grounding The device is not intended for operation as a table unit e Operating the device in the maximum surrounding air temperature and stacking devices When installing the device make sure there is at least one free rack space approx 5 cm above the device because heat is discharged via the housing of the device e Ifyou are operating the device in a 19 switch cabinet install sliding mounting rails for holding the device see on page 24 Installing the device and grounding Warning Only install the device in locations accessible to trained maintenance personnel e If installed in a living area or office environment the device must be operated exclusively in switch cabinets with fi
34. ncy VRRP VRRP tracking Interface Tracking OSPF v2 Ping Tracking RIPv1 RIPv2 and Tracking of static routes Documentation and updates via Internet and GCI FTP Server CONSOLE CBL 12KX Magnum 12KX console attachment cable serial configuration cable ACA21 USB 12KX Magnum 12KX USB auto configuration adapter for local configuration management CONFORM05 12KX Conformal coating for protection against moisture Coats interior PCBs power supply and modules of one Magnum 12K X Managed Switch product Please use this URL for the complete Configuration Guide for the Magnum 12KX http www garrettcom com techsupport insertion_guides 12kxcg pdf 11 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 2 Product Description The Magnum 12KX family provides you with a range of Switch variants You can set up your device individually based on different criteria e Media type e Temperature range e Voltage range e Software variant The Magnum 12KX devices are designed for the special requirements of industrial automation They meet the relevant industry standards provide very high operational reliability even under extreme conditions and also long term reliability and flexibility The devices allow you to set up switched industrial ETHERNET networks that conform to the IEEE 802 3 and 802 3u standards using copper wires or optical fibers in a line or ring structure The devices work without a fan If required t
35. olor Activity Meaning FAULT Signal contact1 Red Lights up The signal contact is open it is reporting an error None Signal contact is closed it is not reporting an error Duplicate IP Red Flashing 4 Reports an IP conflict detection times a period Applies to software releases previous to 06 0 00 LED Display Color Activity Meaning RI Signal contact 1 Yellow Lights up The signal contact is closed in manual operation None The signal contact is open in manual operation R2 Signal contact2 Yellow Lights up The signal contact is closed in manual operation None The signal contact is open in manual operation Applies to software release 06 0 00 and higher LED Display Activity __Color Meaning RI Signal contact 1 Lights up Green The signal contact is open in non manual operation Yellow The signal contact is open in manual operation None The signal contact is closed R2 Signal contact2 Yellow Green The signal contact is open in non manual operation Yellow The signal contact is open in manual operation None The signal contact is closed If the manual adjustment is active on the relay signal contact then the error display is independent of the setting of the signal contact www GarrettCom com ss 32 Magnum 12KX Managed Switch Installation and User Guide 09 11 Port state m 13 5794183415 MMN i i AEII L J ee00e0
36. providing first aid General safety instructions Electricity is used to operate this equipment Comply with every detail of the safety requirements specified in the operating instructions regarding the voltages to apply see page 1 Non observance of these safety instructions can therefore cause material damage and or serious injuries e Only appropriately qualified personnel should work on this device or in its vicinity These personnel must be thoroughly familiar with all the warnings and maintenance procedures in accordance with this operating manual e The proper and safe operation of this device depends on proper handling during transport proper storage and assembly and conscientious operation and maintenance procedures e Never start operation with damaged components e Only use the devices in accordance with this manual In particular observe all warnings and safety related information e Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose e Please note that products recommended as accessories may have characteristics that do not fully correspond to those of the corresponding product This may limit their possible usage in the overall system Note LED or LASER components in compliance with IEC 60825 1 2001 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT National and international safety regulations e Make sure that the electrical installation meet
37. re protection characteristics in accordance with EN 60950 1 etc into the field connection terminals for the supply voltage and do f Warning Never insert sharp objects small screwdrivers wires not touch the terminals There is the risk of an electric shock Environment The device may only be operated at the specified surrounding air temperature temperature of the surrounding air at a distance of up to 5 cm 1 97 in from the device and relative air humidity specified in the technical data e Install the device in a location where the climatic threshold values specified in the technical data will be observed e Use the device only in an environment within the contamination level specified in the technical data Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and operation of this product and are appropriately qualified for their job This includes for example those persons who have been ww GarrettCom com 3 Magnum 12KX Managed Switch Installation and User Guide 09 11 e trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards e trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering e trained in
38. s local or nationally applicable safety regulations CE marking The devices comply with the regulations contained in the following European directive s ww GarrettCom com 4 Magnum 12KX Managed Switch Installation and User Guide 09 11 2004 108 EG Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility 2006 95 EG Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electrical equipment to be used within specific voltage ranges In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 USA Ph 510 438 9071 The product can be used in the industrial sector e Interference immunity EN 61000 6 2 2005 e Emitted interference EN 55022 2006 A1 2007 Class A e Safety EN 60950 1 2006 Warning This is a class A device This device can cause interference in living areas and in this case the operator may be required to take appropriate measures Warning N The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values FCC note This device complies with part 15 of FCC rules Operation is subject to the following two conditions
39. s of the standard s e ISO IEC 8802 03 1OBASE T 100BASE TX 1000BASE T e ISO IEC 8802 03 1OOBASE FX e ISO IEC 8802 03 1OOOBASE SX LX The Magnum 12KX device contains all the function units such as Switch function management function redundancy function voltage connection and management connection e Specific functions of TP TX interface e Link Control _ www GarrettCom com DD 14 Magnum 12KX Managed Switch Installation and User Guide 09 11 e Auto Polarity Exchange e Auto negotiation e Auto crossing device may be connected with a crossed over or an un crossed cable e Specific functions of fiber optic interface e Link Down monitoring The Magnum 12KX devices are Switches with a fixed configuration 1 3 1 12KX 2H 12KX 2L 12KX 1H 12KX 1L with 16 Gigabit ports 1 2 3 4 Figure 1 1 12KX switch 2 LED display elements 3 USB interface 4 V 24 connection for external management 5 4 x Gigabit ETHERNET combo ports 100 1000 Mbit s fiber optic SFP slots Alternative connections 10 100 1000 Mbit s twisted pair RJ45 connections Back of device 6 P1 Connection for the voltage supply 7 Relay 1 signal contact Back of device for device variants with 2 power supply units 8 P2 Connection for redundant voltage supply 9 Relay 2 signal contact 15 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 3 2 12KX 1H1POE 12KX 1L1POE with 16 Gigabit ports and PoE 1 2 3 4
40. stem Location and System Name Configuration of the network address range and the SNMP parameters Saving the configuration on the device Simultaneous configuration of multiple devices Configuration of the port display color red for a connection error With the MNS 12KS L3 software you increase your network security in industrial application areas e ETHERNET Early Warning System Easy monitoring of industrial networks Fast display Interface with diagnostic and configuration programs Low deployment cost Magnum 12KX Managed Switch Installation and User Guide 09 11 1 0 Introduction The GarrettCom Magnum 12K X Gigabit Managed Switch provides 16 Gigabit combo ports with built in SFPs allowing a choice of fixed 10 100 1000 BASE TX connectivity or fiber SFPs The substation hardened Magnum 12KX has a non blocking switching fabric to provide wire speed performance on all ports The Magnum 12KX is synchronized via SNTP or with precision timing using IEEE 1588v2 PTP on all ports which assures accuracy within 30ns The unit is well suited for different needs with environmental certifications including IEC 61850 RoHS compliancy high and low voltage power supply options and optional PoE ports Surveillance and security applications leverage the speed PoE multicast capabilities media flexibility power supply flexibility and more Similarly power utilities can further leverage the timing synchronization as well as redundancy capa
41. sure your own personal safety and to avoid damage to devices and machinery Certified usage The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended or approved by the manufacturer The product can only be operated correctly and safely if it is transported stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Supply voltage The supply voltage is electrically isolated from the housing e Use undamaged parts e The device does not contain any service components Internal fuses are only triggered if there is a fault in the device If the device is not functioning correctly or if it is damaged switch off the voltage supply and return the device to the plant for inspection e Only switch on the device when the housing is closed e Connect the protective conductor before you set up the other connections When removing the connections you remove the protective conductor last e Connect both protective conductors if your device is equipped with two power supply units e Make sure that the cross section of the protective conductor cable is the same size as or bigger than the cross section of the voltage supply cables e Only use connection cables that are permitted for the specified temperature range Magnum 12KX Managed Switch Installation and User Guide 09 11
42. t are installed in close proximity to the device i e less than 3 meters away It is not recommended to use these ports for connection to field devices across longer distances which could cause a significant increase in the ground potential Ground Potential Rise GPR i e more than 2500 V Alternately use F O cables Note In general you should adhere to the following recommendations for data cable connections using copper in environments with high electrical interference levels e Keep the length of the data cables as short as possible ideally max 3m long You should not use any copper data cables for the data transmission between buildings e Power supply and data cables should not run parallel over longer distances and ideally they should be installed in separate cable channels If the inductive coupling has to be reduced the power supply and data cables should cross at a 90 angle e You may also choose to use shielded cables Ground the cable shielding at one point in order to avoid causing a ground loop 100 Mbit s fiber optic connection These ports are SFP slots 100 MBit s F O ports enable the connection of terminal devices or independent network segments in compliance with the IEEE 802 3 100BASE FX standard These ports support e Full or half duplex mode State on delivery full duplex FDX Note Make sure that the LH ports are only connected with LH ports SM ports are only connected with SM ports and MM ports only with
43. t display element 13 Service port 17 Magnum 12KX Managed Switch Installation and User Guide 09 11 1 3 4 12KXR 1H1POE 12KXR 1L1POE with 16 Gigabit ports and PoE ports on rear 5 PoE 6 6 6 Figure 4 Back of device 1 12KXR PoE switch 2 LED display elements 3 USB interface 4 V 24 connection for external management 5 4 x Gigabit ETHERNET combo ports with Power over Ethernet PoE 100 1000 Mbit s fiber optic SFP slots Alternative connections 10 100 1000 Mbit s twisted pair RJ45 connections 6 4 x Gigabit ETHERNET combo ports 100 1000 Mbit s fiber optic SFP slots Alternative connections 10 100 1000 Mbit s twisted pair RJ45 connections 7 P1 Connection for the voltage supply 8 Relay 1 signal contact For device variants with 2 power supply units 9 P2 Connection for redundant voltage supply 10 Relay 2 signal contact Front of device 11 LED device status display elements 12 LED port status display elements 13 LED service port display element 14 Service port The device variants of the Magnum 12K XR with ports on the rear panel have the following characteristics www GarrettCom com ss 18 Magnum 12KX Managed Switch Installation and User Guide 09 11 e The display LEDs are on the front of the device There are 16 LEDs for displaying the status of the Gigabit ETHERNET ports and 6 LEDs for displaying the device status e The supply voltage connection and the ports are on the ba
44. t with link 0 8 W 3 Btu IT h Device at full capacity 16 links 26 W 88 Btu IT h Models with PoE Maximum power Maximum 12KX 12KXR consumption power output Device without SFP modules without TP links 10 W 34 Btu IT h additionally for each connected SFP module 1W 3 Btu IT h additionally for each TP port with link 0 8 W 3 Btu IT h additionally for each TP port with link when one 19 5 W 12 Btu IT h Class0 PD powered device is connected Device at full capacity with 4 x Class0 PD 100 W 136 Btu T h powered device connected 38 Magnum 12KX Managed Switch Installation and User Guide 09 11 Underlying norms and standards Name EN 61000 6 2 2005 Generic norm immunity in industrial environments EN 55022 2006 A1 2007 IT equipment radio interference characteristics IEC EN 60950 1 2006 Safety for the installation of IT equipment EN 61131 2 2007 Programmable logic controllers EN 50121 4 2006 Railway applications EMC emitted interference and interference immunity for signal and telecommunication systems FCC 47 CER Part 15 2009 Code of Federal Regulations Germanischer Lloyd Ship Applications Classification and Construction Guidelines VI 7 3 Part 1 Ed 2003 cUL 508 1998 Safety for Industrial Control Equipment EN 61850 3 Communications networks and systems in stations IEEE 1613 Standard Environment and Testing Requirements for Communicat
45. te The terminal blocks for devices with power unit type H type L are coded to prevent them from being accidently connected to devices with power unit type L type H Connecting the PoE supply voltage optional The devices connected are supplied with PoE voltage 48 V DC safety low voltage via an internal power supply unit The twisted pair cables at Gigabit ETHERNET ports to 4 of the device are supplied with PoE voltage via the wire pairs transmitting the signal phantom voltage 23 Magnum 12KX Managed Switch Installation and User Guide 09 11 Relay signal contact Depending on the Magnum 12K X model equipped with one or two power units you have either one or two signal contacts e The signal contact monitors proper functioning of the device thus enabling remote diagnostics You can specify the type of function monitoring in the Management Pin assignment see fig 6 and fig 7 e Also use the Management to switch the signal contact manually and thus control external devices A break in contact is used to report the following conditions via the potential free signal contact relay contact closed circuit e The failure of associated supply voltage e A continuous malfunction in the device e The loss of connection at at least one port The report of the link status can be masked by the Management for each port In the delivery state link status monitoring is deactivated e A detecte
46. tion of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 4 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate
47. vice is installed in a 19 switch cabinet without mounting brackets increased vibration can cause damage to the device and or its modules 25 Magnum 12KX Managed Switch Installation and User Guide 09 11 Install the mounting brackets to the 19 switch as instructed On delivery two brackets are attached to the sides of the device see figure below e Fasten the device by screwing the brackets to the switch Figure 9 Mounting in the switch cabinet Warning When installing the device make sure the ventilation slots remain unobstructed as otherwise the device can overheat and be damaged Note Fasten the device with two additional brackets at the back of the switch cabinet when operating it in environments with strong vibrations Vertical mounting on the wall Use the pre mounted brackets included in the delivery as shown in the following figure see fig 11 Attach two additional brackets to the device not included in the delivery as shown in the following figure consult the factory Fasten the device by screwing the brackets to the wall e e e Warning AN When installing the device make sure the ventilation slots remain unobstructed as otherwise the device can overheat and be damaged Warning N FIRE HAZARD Install the device in a fire protected shell if you are mounting it vertically Failure to follow these instructions can result in death serious injury or equipment damage Note The shielding groun
48. with each Magnum 12KX Switch base unit that is factory configured for Layer 2 Switch operation MNS 12K Release 1 1 includes support for CLI and scripts MSTP RSTP 802 1w and MRP event log file Syslog SNMPv1 v2 SNMPv3 for access authentication RMON port mirroring address conflict detection network error detection SFP speed sensing and diagnostics temperature optical power port security SSL SSH RADIUS authentication per 802 1x QoS 4 classes port priority per IEEE 802 1D p VLANs per IEEE 802 1q multicast support for IGMP snooping querier unknown multicast detection broadcast unicast multicast limiter GMRP IEEE 802 1d flow control 802 3x Documentation and updates via Internet and GCI FTP Server MNS 12KS L3 LIC MNS 12KS licensed Layer 3 software for use on one Magnum 12KX Switch License cost included with each Magnum 12KX Switch base unit that is factory configured for Layer 3 Switch operation Provides Layer 2 software features plus additional Layer 3 features including full wire speed IPv4 routing with low latency Multi netting Aliasing Net directed broadcasts QoS 8 classes Port based Router interfaces Proxy ARP Static routing with ECMP Equal Cost Multiple Path VLAN based router interfaces CIDR Classless Inter Domain Routing ICMP Router Discovery IRDP Double VLAN Tagging Protocol based VLANs Multicast Routing DVMRP IGMPv1 v2 v3 Multicast routing and IGMP Unknown Multicast Filtering PIM DM Router Redunda
49. xcept chassis is a Reverse Mount unit All signal and power cables are in the rear MAGNUM 12KX Switch Gb Fiber SFPs Small Form factor Pluggable Transceivers MODEL DESCRIPTION SFP12KX SX Gig Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C 1000Mb SX 850nm wavelength 550meters distance nominal 2km per Power Budget SFP12KX LX25 Gig Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C 1000Mb LX 1310nm wavelength 20km distance nominal 25km per Power Budget SFP12KX ZX40 Gig Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C 1000Mb ZX 1550nm wavelength 40km distance SFP12KX ZX70 Gig Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C 1000Mb ZX 1550nm wavelength 70km distance 10 Magnum 12KX Managed Switch Installation and User Guide 09 11 MAGNUM 12KX Switch 100Mb Fiber SFPs Small Form factor Pluggable Transceivers MODEL DESCRIPTION SFP12KX FXMM2 100FX Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C multi mode 2km distance SFP12KX FXSM25 100FX Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C single mode 25km distance SFP12KX FXSM100 100FX Fiber Optic SFP transceiver for Magnum 12KX rated 40 to 85 C single mode 100km distance MAGNUM 12KX MANAGED NETWORK SWITCH SOFTWARE and OTHER OPTIONS MODEL DESCRIPTION MNS 12KS L2 LIC MNS 12KS licensed Layer 2 software for use on one Magnum 12KX Switch License cost included