1. ENERGYMIZER T32 THERMOSTAT USER SECTION PROGRAMMING YOUR THERMOSTAT TIMES AND TEMPERATURES IMPORTANT Set the correct thermostat model which is applicable to your system ae SS a To access these settings the display should show OFF Push the button once and hold for 5 seconds until small Menu 01 is displayed in top left hand side of thermostat Push Olo set your thermostat in the correct mode for your requirements Setting A Air only measures and regulates air temperature in its location for Thermostat only Setting AF Air and Floor measures and regulates air temperature and floor temperature for Thermostat and Floor sensor Setting F Floor Only measures and regulates floor temperature only for Floor Sensor only Setting AR Air only with Remote Air Sensor measures and regulates the air temperature where the remote air sensor unit is located for Thermostat with Remote Air Sensor Unit IMPORTANT Set the current day and time on thermostat L 2 3 To access these settings the display should show ON Push the button once and the time will flash Press the or to change to current time Push the button again and the day will flash Press the or to change to current day With thermostat display ON Program 1 Comfort on Wake Up in the Mornin 1 Press and hold button for 5 seconds until PROG is shown to find the correct day keep pressing the or button until correct day is fl
2. ashing and appears on the display If all days are to be set the same press and hold the or button for 5 seconds this will set all days at the same time each day for Program 1 Comfort on Wake Up in the Morning Next press button Oo display press or button to set the start time for Program 1 factory default is 07 00 Press or button to change the time to your chosen requirement Press button again and use or button to set required temperature for Program 1 Factory default is set at 22 C Choose and set your desired heating temperature then to set the next settings Program 2 Economy when property vacated in daytime press M while temperature is still flashing or wait for flashing to stop and follow instructions below Program 2 Economy when Property Vacated in the Day Time Jip Press and hold button Jfor 5 seconds until PROG is shown to find the correct day keep pressing the or button until correct day is flashing and appears on the display If all days are to be set the same press and hold the or button for 5 seconds this will set all days at the same time each day for Program 2 Economy when Property Vacated in the Day Time Next press lO button 3 times until is displayed to set the start time for the Program 2 Factory default is 09 30 Press or button to change the time to meet your requirement Press button again and use or button to set required temperature for Program 2 Factory defaul
3. hing and appears on the display If all days are to be set the same press and hold the or button for 5 seconds this will set all days at the same time each day for Program 4 Economy when Sleeping at Night Time 2 Next press button 7 times until is displayed to set the start time for Program 4 Factory default is 22 30 Press or button to change the time to meet your requirement 3 Press button again and use or button to set required temperature for Program 4 Factory default is set at 16 C Choose and set your desired heating temperature then wait for the flashing to stop for the settings to save Temporarily Override Temperature If temperature needs to be increased or decreased 1 Press or button once the set temperature will flash on the display 2 Press or button again until temperature you want is displayed 3 Press button to confirm the setting and override will be shown on LCD The thermostat will override the current programme and maintain the new set temperature until the next programme scheduled start time To cancel override setting press and hold button for 5 seconds until override disappears Auto and Manual Setting In Auto mode the thermostat follows the pre programmed times and temperatures set All temperatures can be over ridden in Manual Mode should you wish to increase the temperature at any time on any day Simply Press and hold button when thermostat displays off or press and hold butt
4. on when thermostat displays the on screen this accesses the auto and manual settings Holiday Mode To set holiday mode press and hold button for 5 seconds until Suitcase symbol appears To exit press and hold button for 5 seconds When thermostat is set in holiday mode it will default to 10 C as factory settings Press or button to change the set point and wait for 5 seconds to save and exit Button Lock Press and hold and buttons together for 5 seconds until lock is displayed the thermostat is now locked and cannot be adjusted To unlock press and hold and buttons together for 5 seconds lock symbol will disappear from the screen Resetting Thermostat to Factory Defaults To re set all settings to factory defaults whilst in standby mode and thermostat displays off press and hold button and button together for 5 seconds until RESET is shown for 5 seconds on LCD A Heian Ovoide Bi Holiday moss pF OVERRIDE Temporary Temperature Override
5. t is set at 16 C Choose and set your desired heating temperature then to set the next settings Program 3 Comfort when you return to the property in the evening press M while temperature is still flashing or wait for flashing to stop and follow instructions below Program 3 Comfort when you Return to the Property in the Evenin 1 Press and hold button Jfor 5 seconds until PROG is shown to find the correct day keep pressing the or button until correct day is flashing and appears on the display If all days are to be set the same press and hold the or button for 5 seconds this will set all days at the same time each day for Program 3 Comfort when you Return to the Property in the Evening Next press 5 times until is displayed press or button to set the start time for Program 3 factory default time is 16 30 Press or button to change the time to your requirement Press button again and use or button to set the required temperature for Program 3 Factory default is set at 22 C Choose and set your desired heating temperature then to set the next settings Program 4 Economy when sleeping at Night time press M while temperature is still flashing or wait for flashing to stop and follow instructions below Program 4 Economy when Sleeping at Night Time 1 Press and hold button amp for 5 seconds until PROG is shown to find the correct day keep pressing the or button until correct day is flas

Download Pdf Manuals

image

Related Search

Related Contents

Operator`s Manual  Manual Jacuzzi Filtros Cartucho  Guía del usuario de la base de datos ZESIS  Chèque annuel de formation  InSideControl App InSideControl HD App  Aria - Aria elite - Aria  Mode d`emploi - Husqvarna Viking  Baixar tese  これから山を始める人のための道具選び— 幅広い  Shelf Manager ACB-V R1.0 24.09.08.book  