Home

SONIC PRO S2 tech data

image

Contents

1. 8 inches 55 mm Power Requirements 90 264 VAC 50 60Hz or 15 30 VDC Power Consumption 40 watts maximum Operating Temperature 14 F to 140 F 10 C to 60 C Storage Temperature 40 F to 158 F 40 C to 70 C SONIC PRO Ultrasonic Flow Meters Engineering and lechnical Data Display 320 x 240 pixel QVGA backlit LCD UV resistant Simultaneous Rate and Total 10 digit maximum exponent to E 32 Decimal location factory configured Display Languages English Spanish French or German factory configured Keypad Two button positive action tactile switch keypad Display Volume Units Factory configured Rate and Total display units in U S Gallons ounces BBL barrels US liquid BBL US oil cubic feet acre feet Imperial British gallons ml liter or cubic meter Display Time Units Factory configured in seconds minutes hours or days Display Output Update Time Factory configured for 1 0 seconds Flow Rate Display Averaging Factory configured for 5 0 seconds Data Outputs e Isolated 4 20 mA output factory scaled at 0 30 fps e 0 1000 Hz Pulse output factory scaled at 0 30 fps Data Logging Date time stamped flow rate and total data in FAT32 file format easily imported into Excel Factory configured to trigger at 3 minute time intervals Over 30 000 events with included 32MB SD Card External Communications optional Computer connection via RS 232 RS485 USB Ethernet e In
2. ProSeries SONIC PRO_ Ultrasonic Flow Meters Engineering and Technical Data SONIC PHO Sex Hybrid Ultrasonic Flowmeter Selectable Doppler or Transit Time Non Invasive clamp on transducers High quality QVGA display NEMA 4X IP 66 washdown enclosure Tamper resistant interface Factory Configured Optional Smart external communications 2 Year warranty a NEMA 4xX CE l ptt ttt ty tt tt See A ANA Applications Features e Sewage e Selectable Doppler or Transit Time operating mode e Custom quality metric algorithms and DSP technology ensures reliable high e Wastewater accuracy measurements e Pulp amp Paper Slurries e Quick and easy clamp on transducer installation Proprietary AGC Automatic Gain Control algorithm eliminates manual gain adjustment F OWAE e Tamper Resistant 2 button user interface e Discharge water e Factory configured for easy installation Cau e High quality 320 x 240 pixel QVGA backlit LCD e Data logging to standard SD Card format Factory configured to three minute time e Chemical Slurries interval triggers Logs time date flow rate and total flow values 30 000 events with included 32MB SD Card e Ground water e isolated 4 20 mA output factory configured e Food and Beverage e 0 1000Hz Pulse output factory configured e Optional Computer connection via RS 232 RS 485 USB Ethernet Permits remote access and control of all functions including real time displ
3. User selectable Doppler or Transit Time operating modes Fluid Types Virtually any acoustically conductive fluid Transit time mode operation from 0 to 1 0 to 10 000 ppm particulate Doppler mode operation from 0 02 to 15 200 to 150 000 ppm of 100 micron particulate Nominal Pipe Sizes 0 5 inch 12 0 inch 20mm to 315mm Pipe Materials Most metal and plastic pipes Pipe Liner Materials Most plastic liners Fluid Velocity Range 0 to 30 f s 0 to 9 m s Accuracy Accuracy at Pipe Inside Diameter Doppler all pipe sizes Transit Time 1 2 to 1 1 of rate gt 8 ft sec 0 06 ft sec lt 8 ft sec 1 of rate gt 12 ft sec 0 12 ft sec lt 12 ft sec 2 of rate gt 12 ft sec 0 25 ft sec lt 12 ft sec OWA tals Averaging Time Transit Time 1 1 4 to 12 1 of rate gt 1 ft sec 0 01 ft sec lt 1 ft sec 1 of rate gt 5 ft sec 0 05 ft sec lt 5 ft sec 2 of rate gt 12 ft sec 0 25 ft sec lt 12 ft sec 5 0 Seconds default setting 1 0 Seconds 0 5 Seconds Electronics Enclosure NEMA 4X IP66 Powder coated aluminum stainless steel mounting plates clamps and hardware Dimensions 11 00H x 8 60W x 5 00D inches 279H x 218W x 127D mm Weight 6 8 Ib 3 1 Kg Mounting Wall pipe vertical or horizontal or panel mounting Hardware included Panel opening 10 63H x 8 10W inches 270H x 206W mm Panel Depth Rear 2 78 inches 71 mm Front 2 1
4. ample model number Note Other options available Blue White 9300 Business Drive Huntington Beach CA 92649 All trademarks are the property of their respective owners _ Tel 714 893 8529 Fax 714 894 9492 ieee www blue white com Email sales blue white com 4of 4 TDS 85000 xxx 04202007
5. ay system configuration data logging remote data capture and process control functions Software permits remote internet access through local network set up e Petrochemical e Any sound conducting liquid TDS 85000 xxx 05192007 1 of 4 SONIC PRO Ultrasonic Flow Meters Engineering and lechnical Data Installation Fluid Requirements The Sonic Pro series Hybrid Ultrasonic Flow Meters can measure fluid flow in virtually any fluid in which sound waves can travel The Sonic Pro meters are considered hybrid because they can measure fluid flow using either the Doppler or Transit Time methods The Sonic Pro ultrasonic sound transducers are clamped to the outside of the pipe wall and include no moving parts This method of flow measurement is safe non intrusive and very easy to service The Doppler measurement method requires particles be present in the flow stream to reflect the sound waves The meter may be operated in the Doppler mode when the fluid contains 0 02 to 15 200 to 150 000 ppm of particles The Transit Time measuring method requires relatively clean fluid to enable the sound waves to complete their circuit The meter may be operated in the Transit Time mode when the fluid contains 0 to 1 0 to 10 000 ppm of particles To allow for changes in the fluid s particle count the Sonic Pro monitors the signal gain and employs an Automatic Gain Control AGC algorithm that periodically adjusts the gain maintain th
6. cludes user communication and complete configuration software e Permits remote internet access through local network set up e Remotely access and upload data logging files Clamp On Transducers Housing NEMA 4X IP66 Powder coated aluminum stainless steel mounting clamps and hardware Dimensions 3 12H x 2 95W x 1 60D inches 79H x 75W x 41D mm Weight 0 8 Ib 0 4 kg each Cable Shielded coaxial RG U Type 59 PVC jacket black ROHS Compliant Standard length 10 ft 3m Optional lengths available 25 ft 7m 50 ft 15m 100 ft 30m Nominal Pipe Sizes A series transducer 0 5 inch 2 0 inch 20mm to 63mm B series transducer 2 0 inch 12 0 inch 63mm to 300mm Pipe Surface Temperature 14 F to 212 F 10 C to 100 C TDS 85000 xxx 05192007 3 of 4 SONIC PRO Ultrasonic Flow Meters Engineering and lechnical Data Dimensions 8 600 in oe k o 9 225 in i ME 7 f gs T f S2 Series Hybrid Ultrasonic Flowmeter ig S2 Series 3D0 0 W42 Rate U S Gallons min 625 38 Total Flow U S Gallons 1 0 38 i n 4345625 38 264 mm 11 70 in oe 297 mm 1 513 in 10 38in 38mm 11 00in fe BN i oar 279 mm bz 7 826 in 199 mm i ali y 3 12 in 2 e a sft 79 mm pa 2 95 in 75mm I TRANSDUCER Series A and B With Wall Mount Hardware Model Number Matrix Sonic Pro Part Number Matrix Pipe Base Ele
7. ctronics Package S1 Factory configured without display 2 Factory configured with display 3 Factory configured with user configurable display Smart Communications Power Supply Cord Power Supply Cord Sch 20 ASTM D 1785 c Sch 40 ASTM D 1785 J 2 4 r 1 4 1 2 os N 1 2 ajaj 2 European 220V with CEE 7 VII plug A1 Small pipe lt 2 diameter with 10 ft cable C SDR 21 ASTM D 2241 Stainless Steel 304L A3 Small pipe lt 2 diameter with 50 ft cable SDR 13 5 ASTM D 2241 Stainless Steel 316 B1 Large pipe gt 2 diameter with 10 ft cable 20mm PN 4 Metric DIN 8062 Steel 1 Carbon hardened CLASS B British BS 3506 Fluid Se F AA Alcohol Ethyl alcohol Ethanol AB Benzene illed BS Lar ge pipe gt 2 diameter with 50 ft cable Steel carbon User configured O Select from options list ajae jv rm o Jo lN a Ss 3 3 3 3 3 3 3 i i Select from options list Pipe Material Select from options list Display Volume Units G Gallons o D w 3 3 W J ol O gt lt AD _ AE Gasoline AF Isopropylalcohol AG AH A O IN o O o J JE 3 Methyl alcohol Methanol Methyl ethyl Ketone N Milk homogenized Oil diesel AK Toluene o AM Water heay AN Water sea W JININ IN x lt C s3 c 1 a1 015 sp J cG m at e S
8. e optimum power level The speed at which sound travels in the fluid must be known The factory will configure the meter for a known fluid during the initial configuration The Sonic Pro model S2 offers optional remote PC software that can be used to configure the meter Many common fluids are listed in the software and can be selected directly from the menu Provided the speed of sound in the fluid is known custom unknown fluids can be input manually by the user A list of various fluids and their sound speeds are provided in the user manual Flow Stream Requirements To ensure measurement accuracy requires a fully developed turbulent flow profile Pulsating swirling and other disruptions in the flow stream will affect accuracy Flow conditions with a Reynolds Number greater than 4000 will demonstrate fully developed turbulent flow A Reynolds Number less than 2000 indicates laminar flow and may result in inaccurate readings REYNOLDS NUMBER EQUATION Fully Developed i palate Disturbed Flow due t irli REYNOLDS NUMBER 3160 x QxG Pent Flow due to swirling AMET AR AT AT AT AT ATA A A AA A AA AA AA A AA AA AAA AA AA A AA AA AA A AA AA A A A A A A A Dx V Where Flow rate of the fluid in GPM Q Specific gravity of the fluid G Pipe inside diameter in inches D ABY A A A A A A A A S A A A A A A A A A A TT TTTTTTTTTTD A Fluid viscosity in centepoise V Pipe Cross Section Flow Velocity Profile Minimum Straight Pipe Length Requ
9. irements The meter s accuracy is affected by disturbances such as pumps elbows tees valves etc in the flow stream Install the meter in a straight run of pipe as far as possible from any disturbances The distance required for accuracy will depend on the type of disturbance Type Of Disturbance Minimum Inlet Pipe Length Minimum Outlet Pipe Length Flange Reducer 90 Elbow 10 X Pipe Inside Diameter 5 X Pipe Inside Diameter Two 90 Elbows 1 plane 15 X Pipe Inside Diameter 5 X Pipe Inside Diameter Two 90 Elbows 2 planes 20 X Pipe Inside Diameter 5 X Pipe Inside Diameter Pump Or Gate Valves 25 X Pipe Inside Diameter 5 X Pipe Inside Diameter Transducer Mounting Location The meter can be mounted on horizontal or vertical runs of pipe Mounting on the sides 3 o clock and 9 o clock position on horizontal pipe is recommended Mounting anywhere around the diameter of vertical pipe is acceptable however the pipe must be completely full of fluid at all times Back pressure is required on downward flows to ensure a full pipe See the minimum straight length of pipe requirement chart above The meter can accurately measure flow from either direction NO Pipe must be full Air bubble Down flows must have eow Vo LO Ti LO ls See minimum straight length requirements above NO Sediment 2 of 4 TDS 85000 xxx 05192007 Specifications General Operation Measuring Principle Hybrid