Home

H.264 2Mega-Pixel

image

Contents

1. Megapixel Network camera For your safety and comfort System Information O O IP Address Assigned IP 192 168 1 30 MAC 40 04 0C 01 00 89 O Dynamic DHCP Static IP Address 192 168 1 30 Subnetmask 255 255 255 0 Gateway fi 92 168 1 1 Save DNS 1 st DNS 168 126 63 1 Znd DNS Save Pic 3 10 Network Setting 20 4 DNS Server Setting For setting of ONS server input ONS address to fit with network environment to set Default address is DNS address of Dacom Hanarotelecom Use DNS value normally set in PC Click Save button to save the setting value 5 IP Address Setting Click Static IP Address in IP Setting of Pic 3 10 and input IP Address Subnet Mask Default Gateway Please refer to the manual of IP sharing device and click button to save the setting value Click Save button to save the setting value When Pic 3 11 appears click Click Here to go to changed main page In case of connecting with cross cable may not found the changed page but IP change has been completed Megapixel Network camera For your safety and comfort Reconnect Some times after Click Here lt MA Pic 3 11 IP change 6 Connect the camera to IP sharing device with LAN cable direct cable 7 Connect PC to IP sharing device with LAN cable direct cable 29 Chapter 4 General Information 1 General Information User can find product information as like H W ver
2. Stream Setting Stream Source Codec show hide Stream 1 Input 1 v H 264 v Stream 2 None v MJPEG Stream 3 None v MPEG4 Save 36 6 2 Audio You can configure the I O settings of the audio source from the camera Megapixel Network camera For your safety and comfort Stream Information O O Audio Audio Input F Enable Privacy Zone Gain Ext Video 50 AO HTTPICGI Audio Output ONVIF Fl Enable Gain 50 T Codec u_law y Sampling Rate KHz 6 3 RTSP Setting This camera provides the RTSP RTP stream transmission as well as TCP IP stream The function is based on VLC http www videolan org media player If duplicated port used in this function with the port used from other process it will not be working well RTSP Port Setting of RTSP port default port TCP 554 RTP Port range Setting the port of RTCP with RTP The maximum and minimum have at least 3 range gap RTCP RTCP Time out enable If the server do not receive the RTCP from Client then RTSP session will be stopped Use user authentication Enable To set using for user authority on RTSP session MULTICAST Multicast function transfers the data to multiple users by a single streaming transfer It loaded less traffic in the network than unicast There should however be multi casting functions in all network equipment which is in located in between streaming server camera and clients P address D
3. Pic 3 5 IP change http 192 168 1 31 Manager for Good Camera Windows Internet Megapixel Network camera For your safety and comfort ID Psaaword Viewer D Xx Pic 3 6 IP Change page 20 8 Remove LAN Cable cross cable connected between the camera and PC 9 Connect the camera to network with LAN cable Direct cable 10 Connect PC to network with LAN cable Direct cable 11 Set up IP address Subnet Mask and Gate way of PC according to network environment Recommended to user to remember the value before changing user s PC setting 12 Check Run web browser on PC input IP address set in the unit onto URL and click as Pic 3 7 When main page appears as Pic 3 1 click Viewer button to connect to web viewer and check if IP setting is correct or not Refer to Chapter 2 Installation and video check In case video is not seen check whether there may be confliction of IP in network and recheck the set value of network environment of the camera and network environment of User s PC Web Manager for Camera Windows Internet Explorer se le 192 168 1 30 9 by Pic 3 7 Connect to the unit Reference If you register on DONS server we operate you can use the registered domain name for connection 3 2 2 Dynamic IP Setup Do not set up dynamic IP in the unit except directly connecting the camera to network supporting dynamic IP If the IP has not
4. A IA 43 Chapler S Camera INE OIL OT NN A 44 5 DERE cds 44 op ele geen eee NCR TC Ur eT Cee eeee cer te ree ere retT een y E er ere er ere en ere ere errr 44 SS Wote O dt do 45 EWO a a A O ee Un Re 45 8 5 Digital Noise Reduction DNR ccccccsecccecccuccecuccecuececuececuececsececsececsececsececesecsesecsesecteseeaeeens 46 00 BOO 46 ES ON 46 RTD SR a eT TTT 4T Peor We coe k EEN aE A EAA ARA AA A A A AA AEA 48 OT SCO LTP MINI OP enr E ind 48 Prr G 5 1 EUR STT 5 E aT ae A NN 48 Ng Ze Ee je IG A A AQ Fh ge ese SME PAV Ta c 49 Chapter 10 Basic Network A ES Do UF Fa S Te H TTT 53 RS 62118 B 54 ES E T a A AEA NIN NI NI D5 ANO o caren m en Re Mn ena a RAED ARR A A RENEE AT ETAT 97 a ates cata alaian la laliahelalalebelabetabelibataielelatateladiabel ERREEN Su 11 2 Troubleshooting of cable connection 58 11 3 Troubleshooting of network CONNECTION eee 59 Chapter 12 ooo loin elccmere rene tere Tere twee CNT Une NET Tere yn U On TNOIN TUN NTT IAE 60 Expte ake e icc OE is at hc cg Ieee eaten mettre te tee tet nord eee Rung eed EEEE S Netty eee dius Hama metr ames edi Taree E 61 Introduction This is a megapixel network camera which uses a 1 2 8 inch megapixel progressive scan SONY CMOS sensor Built in H 264 MPEG4 MPEG CODEC and streaming server the advantage of this camera allow you to monitor real time image from a remote location via internet This camera supports both static IP and dynamic IP and can change commu
5. CONNECT the camera with web DEO W SCL ora L7 AE Me OO E A A E AE AEE EE 18 Die C NO D AA E EET E E E E E 18 2 2 0 Installation Complete 20 2 2 6 Net Viewer description eee 21 Chapler O TIDE o 22 3 1 Check Network and Installation TypE id 22 3 2 Installation without IP sharing device router ceeccceecccecccceececeececuececuececaececeececececesenaecens 22 K ezr eT 1 A 6 pee a en cee eh ee ie cee ee ee ee ce cee ee ee ene E ee ee ee eee cee 22 ne TAO TO ere 26 3 3 Installation with IP sharing deviceLrouterl 28 One Te Mer ino o AAA O 28 Chapter 4 General Information see eee 30 Mic ter oo AAA ol Ded Camera Name rss ies iodo bciasa of AAN Ra TT ol 5 3 Administrator s ID and Password Change 0 0 o cee ee ceceececcececceccececceeecescecceceeencescsescesensatenees 92 SAN NO K B11 8 tA ang RRO me ROR ROR RR ERAT AAO RAR RAR TAR AEARRS RA AAENRCIT RAR ET UREARERT RAAT AI ETATS 32 LON DDO enaa a OE oa de le o a N 32 IS a0 Dl Date TE ri 33 5 8 User Registration A TENT Sent Tere rere rere rT 34 Deo Piriniware Aaaa s E NEEE tata tacetereteiatara Sen teeieds ta tesn 00 5 10 System Reset Restart dis 35 Chapter 6 bre alia TEOTIA 36 SA rn EEE T E o EEEE EEEE 36 Sa e enter eee 37 ES DE AREI AE T a EE E E E EE EE EEE E E AE EE SY OEO D rare A A OTOA ATOE 38 AAA A A aaa aaaea 39 AD o AA O O A 39 A A a e en o en ere een ceo Sn Meee 40 a na A A RE 41 bek MOTON rre 41 EAN A PS 41 A eN 42 EPM iii 42 TON 43 A
6. IP Address Subnet Mask Default Gateway Web Port Stream Port ID Please wait 8 sec Pic 5 3 Change of IP address 2 Check the Static IP Address input the information IP Address Subnet Mask Default Gateway Web Port Stream port you want to change 3 Input ID and password 4 Click the Change button After a while setup will be completed 5 Click the Find button one more time to check the changed information Dynamic IP 1 Double click IP address you want to change or check the list on the index and click Change 2 Check the Dynamic IP Address the IP Address Subnet Mask Default Gateway Web Port Stream port will be grayed out 3 Input ID and password 4 Click the Change button After a while setup will be completed And you can find the changed information 9 1 3 2 Change IP address for multiple units lt Procedure gt Static IP a Check the index box of two or more units you want to change Click the Change button The picture of next page will be sh 90 IP Change 40 04 0C 01 00 05 192 168 1 30 TR 200 Z U 192 158 1 1 20 04 0C 00 FF F8 192 168 1351 235 255 255 0 192 158 1 1 Pic 5 4 IP address change window 2 Click the Batch button the dialog appears Pic 5 5 IP address change dialog 3 Check the Static IP Address input the information IP Address Subnet Mask Default Gateway Web Port
7. Stream port you want to change 4 Input the Last Address and step EX If the condition sets like the picture 5 5 the last number of the IP address will be increased each 1 starting 30 and will not over 253 ol 5 Input ID and password and click the Save button After a while the changed IP address dialog appears Pic 5 6 IP Change Subnet Mask Web Port Stream Port 40 04 0C 01 00 05 192 163 4 30 255 255 255 0 192 168 4 1 Static 80 55 40 04 0C 00 FF F8 192 168 4 31 255 255 255 0 192 168 4 1 Static 80 Change Cancel Pic 5 6 Changed IP address dialog 6 Click the Change button After a while setup will be completed T Click the Find button one more time to check the changed information Dynamic IP 1 Double click IP address you want to change or check the list on the index and click Change The picture Pic 5 4 will be shown 2 Click the Batch button the dialog Pic 5 5 appears 3 Check the Dynamic IP Address the IP Address Subnet Mask Default Gateway Web Port and Stream port will be grayed out 4 Input ID and password Click the Change button After a while setup will be completed And you can find the changed information de Chapter 10 Basic Network This chapter is the basic explanation for installation 10 1 Public IP A 0000000047 L e e e m e e e e rra e m m eb Static IP Dynamic P Pi
8. Time sec Previous 0 X Next 10 lt Data Size Limit M v Byte 43 Chapter 8 Camera Information 8 1 Day amp Night This menu is to set IR Cut filter IR LED On Off Color and B W mode Auto It is function that changes the colors to B W or B W to colors by set switching point Adjust properly the switching point when day and night changed Day The picture is always displayed in Color using IR cut filter Night The picture is always displayed in B W Don t use IR cut filter Activate IR LEDs Checked this menu IR LEDs turn off or on according to Day or Night mode If not checked it IR LEDs are always off Megapixel Network camera ei Pat RZ PS For your safety and comfort Camera Control O Day amp Night Day amp Night Change 5 Day Color 5 Night B W Auto D amp N Change Point Dark A Bright Night Day Night Day 740 1 313V 620 1 103V CDS ADC D amp N Change Interval 5 Sec 7 LHR 50Hz show hide Y Activate IR Leds 8 2 Color You can change the camera color settings according to the environment where the camera Is located x Sharo Adjust the sharoness of picture As the level of sharoness increases the screen gets sharper and the level of noise also increases x Edge Enhance The higher the level is the sharper and clearer the outline of the image becomes Megapixel Network camera For your safety and comfort Camera Control Color adjust
9. address reset hardware and connect PC with the camera through cross cable and ping test by entering 192 168 1 8 3 In case camera uses private IP through IP sharing device Do ping test of private IP address set for camera in PC that is connected in the local network through IP sharing device Reference Please refer to PING Test of Basic Network If ping test get response network setting for camera is done correctly Ping test is okay but there is no connection check with 7 3 2 check port setting 11 3 2 Check port setting If user cant connect with camera even though Ping test is okay please check port setting by the following steps The unit uses 3 ports as follow Web Connection Port Port 80 TCP Authentication Control and video streaming port Port 9000 TCP Not available to connect to web If it is not available even to connect to web check web connection port because web connection port may be set with other number is not 80 Use IP Finder program Default value of web port is 80 Reference Web port 80 can not be available in some internet service In this case go to the administrator s page and change the web port 2 Problem in video monitoring In case there is problem in video monitoring even though there is no problem in web connection check if Authentication and Control Port and Video Streaming Port of the unit is set on IP sharing device Refer to the manual of IP sharing device
10. installation is complete 17 2 2 3 See the video Shown as Pic 2 3 inout ID and password and click on Viewer to see the video feed User s authority to see the video feed is as follow Stream admin admin All Web management ret et Ar Soe Table User ID Password Authority Caution You must change default value of ID Password into new ones after installation 2 2 4 Active X auto installation If connecting to a camera for the first time you will see the installation message Click install on the security certificate to load the Active X control If you choose Don t install the web viewer would not work 18 Megapixel Network camera For your safety and comfort d Click here to install the following Activex control netview from samhyunelectronics Stream D Megapixel Network camera For your safety and comfort G Click here to install the following Activex control netview from sambhyunelectronics Install this add on for all users on this computer What s the risk Windows Internet Explorer To display the webpage again the web browser needs to A resend the information you ve previously submitted If you were making a purchase you should click Cancel to avoid a duplicate transaction Otherwise click Retry to display the webpage again G User Account Control D Do you want to allow the following program to make changes to this c
11. regarding Port forwarding Reference It is strongly recommended to register the number under 9999 of port Port Number more than 10 000 can not be available in some network DY Chapter 12 Troubleshooting Check if the power cord and line connection Nothing appears between the camera and monitor are connected on the screen properly The image on the Check whether the window is stained screen is dim li dirty dean the lens with solt and clean cloth Dose the camera face to the sun directly or fluorescent ight Change the camera position The image on the screen flickers Adjust the contrast feature of the monitor If the camera is exposed under too strong ight change the camera position solution The contrast on the screen is too weak xX If you can not solve the problem please contact an authorized technician 60 Chapter 13 Warranty Card PRODUCT NAME eg FOR ONE YEAR DATE OF PURCHASE AFTER THE DATE OF PURCHASE PERSON IN CHARGE 61
12. Bright O OO Contrast 1 CT Saturation QD _ _ _ _ _B Sharp 64 _Bs Edge Enhance a A _ Default Save 44 8 3 White Balance Auto Adjust white balance automatically Indoor Adjust white balance to indoor environment 3200 k Outdoor Adjust white balance to outdoor environment 5600 k Fluorescent Adjust white balance to fluorescent environment 4000 k User User can adjust the red and blue gains of the camera video manually Megapixel Network camera For your safety and comfort Camera Control Day amp Night White balance Color White Balance Auto Indoor C Outdoor Fluorescent WDR C User DNR oir 53 ma Effect Bed 63 7 Sense Up Blue 34 SSS e Shutter Speed Default Save 8 4 WDR It displays a sharp image of the objects in a scene where both bright and dark areas exist Back light Enhance the object image contrast when light is coming from back of it Front light Enhance the object image contrast when light is coming from front of it At night WDR function is not available Megapixel Network camera For your safety and comfort Camera Control Day amp Night Color O WDR White Balance Enable WDR C Light Compensation DNR Back light Front light Effect WDR Sense Up C Step 1 C Step 2 Step 3 C Step 4 C Step 5 Shutter Speed Save 4d 8 5 Digital Noise Reduction DNR It is used for re
13. Class IP address should be allocated for the multi cast D Class IP address is 224 0 0 1 239 255 255 254 Port 4 000 default port 37 Time to live TTL TTL is reduced one by one when it is transferred each router When it reaches to O value the router will discard the data The TTL Value determines how far the data is delivered Generally the value is 128 Megapixel Network camera For your safety and comfort Stream Information RTSP RTSP Port 554 3000 60000 554 Use Time Limitation 30 gt sec RTP Port Range 0o00 563 83 3000 60000 RTCP M Enable Multicast M Enable TTL E Set Video Stream IP Address 239 249 119 123 D Class Port a000 300060000 Set Audio Stream IP Address 239 249 119 129 D Class piit a008 3000 60000 User Authentication M Enable 6 4 OSD Configure the settings as necessary of OSD in stream For your safety and comfort Stream Information OSD Display l Enable R Text Camera M Date YYYY MM DD M Time M Event M D amp N M Motion M Alarm Input M Alarm Output Font language English size Big color White gt 38 Megapixel Network camera y m Save Save 6 5 Privacy Zone You can specify a certain area of the camera video to be protected for your privacy Check the Enable to activate the function Show is to specify the privacy zone x You can specify up to 6 zones Megapixel
14. For your safety and comfort Reconnect Some times after Click Here Pic 3 9 Dynamic IP Setting ar 6 Remove LAN cable cross cable connected between the camera and PC 7 Connect the camera to network with LAN cable direct cable 8 Connect PC to Network with LAN cable direct cable 9 Set up IP address Subnet Mask and Gate way of PC according to network environment 10 Installation check If you have the DHCP server to assign an IP Address First close the web browser you can find out the IP address using program of IP Manager in installation CD Please refer to 9 1 Use of IP Manager If you found the assigned IP to unit rightly open the web browser input IP address of the camera then press the ENTER key The main page will be shown as Pic 3 1 lf you couldn t find the unit it means IP has not been allocated to the unit so you have to press the FACTORY RESET BUTTON for 3 sec then try to again lf you turn off the camera and reactivating in dynamic IP environment might be change the IP address So if you register the IP address to DDNS server you can use the domain name 3 3 Installation with IP sharing device router 3 3 1 General Installation 1 Connect the camera and PC with LAN cable cross cable 2 After checking video in 2 Installation and video check then go to the next step 3 Go to network setting page of Administrator s page as per 3 4 5 of 3 2 1 Static IP Setup
15. H 264 2Mega Fixel NETWORK IR CAMERA USER MANUAL lf the product is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment Please read the instructions carefully for correct use of the product and preserve it for reference purposes This specification is subject to change without any prior notice to improve the quality o o A o E E 6 Safety C GUT ONS ds 6 Mi A o o AA T dd Camera Features E E E E E E E E E E T A o EEEE EAE EA EAN OE E A EE E E EE EA RAA EA NN EA NAE EA E EA EEE E ee re ere 7 1 3 HOW TO INSTALL iaa S 1 3 1 Package Accessories for installation e 8 IA Gall AOU aaa a taka O O OI A 8 I e R cate Eao aa EEEE 10 ia 11 LE e A Ll E ES iee o in T gC ee re enn rere PCP tr re are 11 PA r UIC ple snanhnasinasseassanssnandnadbeadoausena sana sanadapasnnadenannnnssnsssnasanassasbeassanssanntnnanadbnadends La LAO Network dada 12 kA L BECAS gt DECIA CION eaei E E E IE Be a O ahha sees ae A A at eee NINO 14 1 4 6 Audio Input Output cccccccesccsccecceccescesccsccecceccescessesccsccscescesscescusceseesceeceeccsceseusseeseusees 14 Chapter 2 Installation and Video check oe ececececcccscecectccscecectacucecsctacsceesesacscecsetacscessctacseeesesaceces LS Zima nS AOT AAPP terry rer terry rernerererrrereretreererrenrrrerrrereverenererernrerrer tre 15 De AAA AA 16 2 2 1 Change the setting value of PC network environment e 16 2 220
16. Input Output gt lt e S v o S o lt 3 9 JEHO 1 4 6 Audio Input Output Inside of the unit 4 Alarm in GND 012V DC 100mA out Alarm out Inside of the unit a 9 Max 100m4 open collector RCA RED MIC 14 Chapter 2 Installation and Video check 2 1 Installation On the assumption that User PC and the camera are used under static IP and the camera is to be directly connected with User PC or Local Network The installation procedure is to be 1 Connect the camera and PC with LAN cable Direct cable or cross cable Please use the direct cable if you connect to local network 2 Power on camera Using regulated 12V DC 500mA No IR LED model or 1A Built in IR LED model x Using PoE Power Over Ethernet This camera adopted PoE that supplies power in addition to data sending and receiving using LAN cable without separate power connection and it provides convenience for users at installation When you connect the camera with PoE and DC adaptor only PoE is used 3 Wait about 2 minute after on camera the system will be booted D Camera 192 165 1 30 PC 192 168 1 50 PC 192 168 1 50 LS 2 2 Video check Basic network setting value of the unit is to be IP Address 192 168 1 30 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 To connect the unit in user s PC change the setting value of PC network environment Set IP Address Subnet Mask and Gate w
17. Network camera For your safety and comfort Stream Information 1 O Privacy Zone TT Enable Area Color Show Area 1 y white y Iv Reload Save 6 6 External Video Analog video output for installation You can set the video output type to either NTSC or PAL Default is set to Enable After installation you must deactivate this function to improve camera performance Megapixel Network camera For your safety and comfort Stream Information External Video Type C NTSC 60Hz PAL 50Hz External Video Output M Enable Disable External Video after the installation It might cause video stream unstable Save 39 6 7 HTTP CGI This function transfer the stream by using Server Push method and can use the control function by CGI calls EX Port I O control Good point of this function is using web port so it is able to transfer the stream and control which is not affected by fire wall Megapixel Network camera For your safety and comfort Stream Information HTTP CGI Protocol Y Use Control Privacy Zone Save Ext Video HTTPICG ONVIF 40 Chapter 7 Event Information 7 1 Motion Enable To use motion detection function click Enable sensitivity Level Setting up sensitivity to detect motion to adjust input video by situation You can select 1 5 and 5 is the highest Megapixel Network camera For your safety and comfort Event Informatio
18. atistics for 192 168 1 38 Packets Sent 4 Received Lost 4 10H loss C MDocuments and SettingsWAdministrator m Ping Failure Goeping 1927 168 1 368 Pinging 192 168 1 36 with 32 bytes of data Reply from 192 168 1538 bytes 32 timetims Reply from 192 168 1538 bhytes 32 time 2ms Reply from 192 168 1358 bhytes 32 timetims Reply from 192 168 1568 bhytes 32 timetims Ping statistics for 192 168 1358 Packets Sent 4 Received 4 Lost Approximate round trip times in milli second Minimum Ams Maximum 2ms Average Ping Success o6 Chapter 11 Appendix 11 1 Basic setting table Static IP Dynamic IP Static IP Enable IP Server IP address Gateway 192 168 1 1 Subnet Mask ANA ROO U Web Connection Port Do not duplicate the same Port RIP port range 5000 5999 ID and Password admin admin User ID Password root root guest guest A Domain of Related Server DONS Server iplinker net Domain of server to connect to register IP stream setting Stream 1 H 264 15fps 1920x1080 risp lt ip 4 gt 554 stream1 None rtsp lt ip 2 2 gt 554 stream2 None rtsp lt ip 2 2 gt 554 streams3 Video output Off After installation deactivate it Other setting Reference In case to reset hardware and network setting ID and password of user and Administrator ID Password Stream 2 Stream 3 Administrator will be automatically returned to the above defau
19. ay of user s PC with 192 168 1 50 255 255 255 0 192 168 1 1 as shown on Pic 2 1 Caution Before changing the setting value please memorize the previous setting value on your PC 2 2 1 Change the setting value of PC network environment Internet Protocol TCPAP Properties ee General You can get IF settings assigned automatically it your network supports this capability Dthermaze you need to ask pour network administrator for the appropriate IP settings C Obtain an IF address automatically e Use the following IP address IP address Subnet mask Default gateway e Use the following ONS server addresses Preferred DNS server 168 Alternate DNS server Pic 2 1 Network Setting for User PC 16 2 2 2 Connect the camera with web browser f Web Manager for Camera Windows Internet Explorer lt f le 192 168 1 30 9 by Pic 2 2 Web browser address Input 1 Run web browser as shown Pic 2 2 2 Input 192 168 1 30 default value in URL and press ENTER button 3 And then Pic 2 3 is to be shown A Manager for Good Camera Windows Internet Explorer Manager for Good Camera a A Megapixel Network camera For your safety and comfort ID admin Psaaword econo Viewer D Manager 4 a AL Pic 2 3 Main Homepage 4 In case Pic 2 3 does not appear press factory reset button for 5sec to reset hardware 5 Shown Pic 2 3
20. been allocated to the unit in dynamic IP setting please press the FACTORY RESET BUTTON for 3 sec then try to setup again 1 Connect the unit and PC with LAN cable cross cable 2 Cable connection and network setting should be done same as Chapter 2 Installation and video check and check video 3 Go to network setting page of administrator s page as per 3 4 5 of Static IP Setup If you will not connect provided internet line from ISP nternet service provider to unit via router and you will connect to unit directly we recommend to you to keep the MAC address on the network setting page It needs to when register to DDNS server 20 Megapixel Network camera For your safety and comfort system Information IP Address Assigned IP TT eu C Dynamic DHCP Static IP Address Subnetmask Gateway O DNS tst DNS Znd DNS 192 168 1 30 40 04 0C 01 00 89 192 168 1 30 255 255 255 0 fi 92 168 1 1 168 126 63 1 Save Pic 3 8 Network Setting 4 DNS server setting For setting of DNS Server input DNS address to fit with network environment to set Default address is DNS address of Dacom Hanaro telecom Use DNS value normally set in PC DNS address should be necessarily input Click Save button to save setting value 5 Dynamic IP address Click on Dynamic IP Address in IP Setting Click Save button to save and Pic 3 9 will be shown Megapixel Network camera
21. c 6 1 Internet environment All hosts connected to internet have the exclusive number called IP address Communication among hosts is available by using it There are two ways to allocate IP address One is fixed by the way of static IP address whenever connected to internet And the other is assigned by a server using Dynamic Host Configuration Protocol DHCP It is Dynamic IP In case of Dynamic IP when turn off the computer automatically return the IP to DHCP due to using that IP in circulation Determined way of assigned IP by network policy so please ask to network administrator or ISP Internet Service Provider In case of using Firewall the camera might be out of working Please ask network administrator then open the service port O 10 2 Private IP Pic 6 2 Internet connection by IP sharing device The most common use of these addresses is in home networks since most Internet Service Providers ISPs only allocate a single IP address to each customer but many homes have more than one networking device for example several computers or a printer That s why we recommended use IP sharing device IP sharing device uses only one public IP Private IP is allocated such as 192 168 xxx xxx and can not be used as public IP When using the router connect the router and input IP address of the unit IP address of the unit is set as 192 168 1 8 on ex factory in DMZ menu If the user cannot use the DMZ functio
22. ddress Subnet Mask Web Port Stream Port 3 6 7 E 9 10 11 il Pic 5 1 IP Manager Description of IP Manager function select all units of the list 9 Gateway information of the unit Deselect all units IP type of the unit Static IP Dynamic IP Delete the list Web port number to connect Consecutive number of the list The cameras that are currently connected to the network MAC information of the unit To change the information 7 IP address of the unit Exit the program 48 4 scans for cameras that are currently stream port number connected to the network 9 1 2 Find IP address Click Find button to find the cameras that are currently connected to the local network Below picture will be shown after IP finding completed IP Manager Select All b Select ne List Clear L 255 255 255 0 192 168 1 1 2 40 0 0C 00FFF8 192 168 1 31 202020 20 0 192 168 1 1 Static B0 Pic 5 2 IP finding completed User can connect easily by inputting the information of IP address and web port 9 1 3 Change IP address After finding IP address if you want to change IP address Gateway or Subnet Mask double click IP address you want to change or check the list on the index and click Change 9 1 3 1 Change IP address for one unit lt Procedure gt Static IP 4 Double click IP address you want to change or check the list on the index and click Change 49 IP Change e e
23. duce noise in the picture at low luminance Megapixel Network camera For your safety and comfort Camera Control Day amp Night Color Digital Noise Reduction DNR White Balance WDR Value 10 C DNR Effect S Save Shutter Speed 8 6 Effect Color Bar Display color bar picture Mono Change color picture to B W Negative Reverse the brightness and color Megapixel Network camera For your safety and comfort Camera Control Day amp Night Fetes Camera Effect White Balance Color Bar ON te OFF WDR Mono C ON OFF se Negative ON G OFF Sense Up Save Shutter Speed 8 Sense Up This is relating to sense up function Low shutter speed which can gather more light by increased exposure of the light is suitable for the dark circumstances and at night Using this mode you can distinguish the outline and the color of the objects But regarding moving objects its outline might not be clear And excessive Sense up function might effect on motion detection Megapixel Network camera For your safety and comfort Camera Control Day amp Night Sense Up M Enable Color White Balance WDR 4 Value 2 CT DNR Effect Sense Up Default Save Shutter Speed 46 8 8 Shutter Speed Adjust the electronic shutter of the camera Auto Control shutter speed from 1 30 to 1 9000 second automatically to have the best image depending on the variable light condition Supp
24. ge the password and ID of administrator Zo 5 Network Setting Click Network Setting on Pic 3 3 Pic 3 4 appears Megapixel Network camera For your safety and comfort System Information O O IP Address Assigned IP 192 168 1 30 MAC 40 04 0C 01 00 89 sat mea N feb O Dynamic DHCP Static IP Address 192 168 1 30 Subnetmask 255 255 255 0 Gateway 192 168 1 1 Save DNS st DNS 168 126 63 1 2nd DNS Save Pic 3 4 Network Setting 6 DNS Server Setting For setting of DNS server input DNS address to fit with network environment to set Default address is DNS address of Dacom Hanaro telecom Use DNS value normally set in PC DNS address should be necessarily input Click gt button to save setting value 7 IP address setting Click Static IP Address in IP Setting of Pic 3 4 and input IP Address Subnet Mask Default Gateway according to network environment Click button to save setting value Click Click Here upon appearing of IP change window of Pic 3 5 As IP Change page appears as Pic 3 6 the main page of changed address is connected May not find the main page of changed address under cross cable connection but IP has been changed 24 Megapixel Network camera For your safety and comfort Server Name Language Administrator Reconnect Some times after Click Here Date amp lime User Reastraton f W Update Reset Restart
25. iod Caution The time is changed to default time when the camera reboot 33 Megapixel Network camera For your safety and comfort System Information Q Server Date bere Current Date 2011 12 15 15 43 19 Network G Auto NTP Web port Time Server Asia 7 Seoul korea Time Zone ntp uio no C User Set Year Month Day Time Minute 2011 12 15 15 lt 43 y Sync PC Save Daylight Saving Time DST l Enable Month Week Day of Week Time Begin 3 7 Second lt Sun lt 2 Finish 11 First Sun y 2 5 8 User Registration This is to register an account of user who monitors and controls video Administrator s ID and password should be English within 20 characters without space Allow the authority to users and click Save button A maximum user to allow registration is 20 persons Click Delete for deleting user Megapixel Network camera For your safety and comfort system Information User Registration for stream ID Password Permission viewer user CO all Save User List t Restart ID Password Permission admin shares ts admin root KERKREKE all Delete viewer Delete KERR guest 34 5 9 Firmware Upgrade In case firmware is upgraded in the near future our upgrade server htto iplinker net will automatically upgrade firmware of the unit Megapixel Network camera For your safety and comfort System Information Serve
26. ithout space Click Save button to save the changed value after changing Administrator s ID and password In case of forgetting Administrator s ID and password click Factory Set button for 3 sec to return to initial value and change Administrator s ID Megapixel Network camera For your safety and comfort system Information Server Name Administrator s Information Language de Administrator current Network Password levees Web port New DDNS ID admin Date amp Time Password conos User Registration Confirm levees FAV Update Reset Restart Save lt Caution gt Change Administrator s ID and password and do not disclose the information to others 5 4 Network Setting This is to set network Set network to fit user s network environment in 3 Network Setting Change network information to fit environment for the unit to be installed in 5 5 Web port Set a web port Web port used to access the camera via the web browser The default is 80 When several network cameras are connected to one IP Router you should forward the web port of the router to the web port of a connected camera You can change the ports of the camera except the specified port Megapixel Network camera For your safety and comfort system Information Server Name A O Webserver Port Language Administrator Port Number 80 3000 60000 80 l etw ol K Web port Save DDNS Date amp Time User Registrati
27. lens 11 1 4 2 Camera Function DAY amp NIGHT Auto Color B W WDR step 1 Step 5 Back light Front light sense up Xi X6 Brightness Adjustable Contrast Adjustable Sharpness Adjustable White Balance AWB Auto Indoor Outdoor Fluorescent Manual Saturation Adjustable Edge Enhancement Adjustable Negative Off On Pattern Generator Off On Slow shutter Level 1 6 EZOOM X1 X12 Selectable Available with CMS only 1 4 3 Network Specification Leased Line Cable Modem Support Dynamic IP Network support and Static IP ADSL usable under Router Summary TCP IP UDP IP RTP RTSP RTCP NTP HTTP DHCP Supported Protocol FTP SMTP DNS DDNS 12 1920 x 1080 1280 x 1024 1280 x 960 Resolution 1280 x 720 1024 x 768 640 x 480 320 x 240 MAX 30fps 1920X1 080 Recording in client PC with CMS or Video Recording FTP Server upon Alarm Event Motion Detection support Function Alarm Input Output Input 1 Output 1 Digital output Open collector Dynamic IP Support IP Router support DDNS Support 1 4 4 Electric Specification Classification Specification Power Supply Regulated 12V DC PoE Power over Ethernet IEEE802 3af Class 0 Current Consumption MAX 1A 12V DC IR LED ON Operation Temp bk ART Preservation Temp 20C 60 Dimension 86 4 W X 101 9 H X 131 3 D mm The specification is subject to change without any prior notice to improve the quality lo 1 4 5 Alarm
28. lt value 07 11 2 Troubleshooting of cable connection 11 2 1 Power cable connection check Check if the power cable is connected to the camera properly x Check whether the output of the adaptor is regulated 12V DC 1A for built in IR LED model or 500mA for No IR LED model 11 2 2 Network cable LAN Cable connection check Check whether the network cable is connected correctly Caution Use direct LAN Cable or cross cable according to network condition Refer to chapter 2 Video check Cable check Direct Cable Hold each end of both side and check if same color s cable is connected to same location in RJ45 jack or not Connection with IP sharing device or cable modem A B C 1 White and Orange 2 Orange 3 White and Green 4 Blue 5 White and Blue 6 Green 7 White and Brown A 1 8 B 1 9 8 Brown Cross Cable Hold each end of both side and check whether 1 2 Tx Tx and 3 6 Rx Rx are cross or not Connection with PC D 1 White and Green 2 Green 3 White and Orange 4 Blue 5 White and Blue 6 Orange 1 9 1 Z 7 Hia Brown C D abi 08 11 3 Troubleshooting of network connection 11 3 1 Cannot connect with network Check with 7 2 2 Network cable LAN cable and cable connection check PING Test In case camera uses Static Public IP input Ping IP address to command window of PC and check response 2 In case camera uses dynamic public IP If user cannot find camera s IP
29. n 7 O Motion R Enable Sens y Lave h 2 gt 4 Test Save 7 2 Alarm Input 1 Alarm Input Click Enable to activate the alarm input function 2 Type Select Normal Close NC or Normal Open NO Circuit of N O type is usually open and the activation of the sensor occurs at the time of close and N C type works reverse way x Alarm input can be interlock alarm output email notification and FIP Megapixel Network camera For your safety and comfort Event Information Alarm Input Sensor C Enable Type C NC NO Test Save 41 7 3 Alarm Output 1 Alarm Output Click Enable to activate the alarm output function 2 Linkage Alarm input Alarm output function operates only by alarm input event Motion Alarm output function operates only by motion event 3 Duration Time Set duration time upon alarm events 4 Test Alarm output is activated by compulsion and you can check the action internally Megapixel Network camera For your safety and comfort Event Information Motion Alarm Output Alarm input Alarm Output Enable E malli Link M Motion M Alarm input FTP Time Sec 5 Record Test Save 7 4 E Mail You can configure the E mail setting so that you can send email to your PC If an event occurs x The Subject should be within 30 characters and the Message should be within 50 characters Megapixel Network camera For your safety and comfor
30. n because there is no DMZ menu in the router or some other reasons go into Port Forwarding or NAT menu on the router and map the port of the unit one by one Reference Private IP range to use private address is hereby CLASS A 10 0 0 0 10 255 255 255 CLASS B 172 16 0 0 172 381 255 255 CLASS C 192 168 0 0 192 168 255 255 x For more detailed information please refer to manual of IP sharing device 94 10 3 Ping test Ping is the test to check response among the devices connected with network Input Ping IP address to command window of PC and check response In case of Ping failure there is some communication problem between the devices By firewall this test can not be available D Tour Windows XP go Help and Support PP Files and Settings Transfer gt Search Vizard All Programs gt Log OFF Turn OF Computer Type the name of a program Folder document or Internet resource and Windows will open it For you cmd a COAWINDOWS Ys ystem32Pfcmd exe Microsoft Windows AP Version 5 1 2600 CG Copyright 1985 2681 Microsoft Corp C PDocuments and Settings Administrator 99 ex CW WINDOY stem32Wcma Microsoft Windows AF Uersion 5 1 2600 CC Copyright 1985 2601 Microsoft Corp Co Documents and SettingsWAdministrator ping 192 168 1356 Pinging 192 168 1 3868 with 32 bytes of data Request timed out Request timed out Request timed out Request timed out Ping st
31. nication port resulting in one IP address supporting multiple servers It also supports CMS Central Monitoring System various services and features waterproof for outdoor use without extra device lt Caution gt Software server and service may be charged according to change of policy or may be stopped without prior notification Appearance function and specification may be changed without prior notification Our company assumes no responsibility for visible or invisible loss resulted from changes in policy or products Safety Cautions This camera may be damaged by electrical and physical shock Use regulated 12V DC 1A power supply Do not throw or drop it onto floor In case the unit fails DO NOT try to disassemble the product Contact or consult the distributor or an authorized technician for after sales service Warranty void for the product disassembled without an authorization from the distributor or an authorized technician All responsibility by using this unit is on the user In case it is installed at high location be sure to mount securely to prevent the unit from falling below Chapter 1 Package 1 1 Camera Features 1 2 Built in 2Mega pixel 1 2 8 progressive scan SONY Exmor CMOS sensor 3 Triple codec H 264 Mpeg4 MJPEG 4 This camera has a mechanical exchange of two filters with Sense up function to Firmware upgrading and function controlling are available by network receive the ma
32. ntrol board O o Ly EXT VIDEO 4 Focus Zoom adjustment direction 1 Unfasten the screw of the bottom door Z Adjust the Focus and Zoom timmers 3 Tighten the screw of the bottom door FOCUS ZOOM Use a type driver for adjusting Zoom and focus In case of operation Zoom Focus don t put stress excessively 3 EXT VIDEO Extra video output terminal for installation Plug your test monitor in hear The cable is option 4 POWER Light would turn on when power is on 5 Rx Tx Light would turn on when the user connect by the network 6 Link Light would turn on when the LAN cable is connected to the unit SYSTEM RESET Press the button to reset when the unit is not working normally FACTORY RESET Turn on the power and wait 2 minutes Press the button for 3 seconds to set the ID and Passwords for administration and IP setting values to the Factory default Reference Please refer to 2 2 Video Check in Chapter 2 and Chapter 5 System Setting regarding default value 10 1 3 4 Dimension 1 4 Specification 1 4 1 Camera Specification Megapixel network camera 2 Mega Pixel SONY Exmor CMOS Image Sensor 2000 H x 1241 V approx 2 48M pixels 1984 H x 1255 V approx 2 43M pixels 50dB CVBS 1 0Vp_p 752 composite for installation 1920 x 1080 1280 x 1024 1280 x 960 0 01 Lux Sense up Auto x 4 LED OFF O Lux 70 Range LED ON Input 1 output 1 TOPES Vari focal auto iris megapixel
33. o 3 2 2 Dynamic IP Setup lt Installation with IP sharing device gt Should set up with Static IP refer to 3 3 Installation with IP sharing device 3 2 Installation without IP sharing device router 3 2 1 Static IP Setup 1 Connect the camera to PC with LAN cable direct cable or cross cable 2 Cable connection and network setup should be same as in Chapter 2 Installation and video check 3 Connect the camera to Web Run web browser and input http 192 168 1 30 default value in URL and press ENTER button then Pic 3 1 will be shown ZZ Manager for Good Camera Windows Internet Explorer l Oj x PE y s v x CIT Jie htp z 192 168 1 30 EA ia 96 fr Naver B gt Manager for Good Camera Megapixel Network camera For your safety and comfort ID admin Psaaword lsssss wi A A Oe OD A AE Pic 3 1 Main Page 4 Administration page log in Shown as Pic 3 1 input ID and password and click on Manager to see the admin page Megapixel Network camera For your safety and comfort General Information General Disronsor Sida Camera Name Camera01 Resolution Max 2M 1920x1080 IP Address 192 168 1 30 MAC Address 40 04 0C 01 2B A3 H W Version AH65 MALO001 V0 02 F W Version AS65 ALL001 V0 02 00 Stream Connection Stream 1 h 264 1920x1080 rttsp 192 168 1 30 554 stream1 Caution If you logged in first in administrator mode please chan
34. omputer pa a Program name netview Verified publisher samhyunelectronics File origin Downloaded from the Internet Show details Change when these notifications appear Pic 2 5 ActiveX Download 19 2 2 5 Installation complete Upon installation Web Viewer Pic 2 6 appears and image of camera is to be seen 17 18 15 16 Megapixel Network camera For your safety and comfort GANGA 200001071 COWS E H 264 1280x1024 v wor Cira we dn TLT TTT TTT TITI Pic 2 6 Web Viewer Installation and check video are completed successfully Must change ID PASSWORD 20 2 2 6 Net Viewer description ltem 1 Stream selection 2 Window size 3 Connection Disconnection 4 Recording 5 Capture 6 Saving path 7 9 PC Speaker 8 11 PC Mic O 1 2 mln O 13 Status Icon 14 Status Icon 15 Camera name 16 Date 17 Time 18 Status Icon Description Select stream codec and resolution menu related to live view was defined only by the admin H 264 MPEG MJPEG Default size is 640X480 Adjust the screen to the optimal size Recommendation Select the same size with stream resolution Connect or disconnect to the stream Saves the stream as a moving picture file in the avi format Saves the snapshot as an image file in the omp format Specify the file saving path Turn ON or OFF the PC s speaker by clicking the icon Turn ON or OFF the PC s microph
35. on FNY Update Reset Restart 32 5 6 DONS DDNS is an abbreviation of Dynamic Domain Name Service that converts the IP address of a camera into a general Host Name so that the user can easily remember it 1 Click Enable 2 Enter the product domain name over 4 characters and email address 3 Perform the duplicate check for the domain that you entered by clicking Check 4 Click Register then you should make sure whether the Status is Register OK or not 5 Click Unregister to delete registered domain name Megapixel Network camera For your safety and comfort System information Server Name DDNS Language Administrator Enable Network Domain Name iplinker_net E mail Status Use after registration Web port DDNS Date amp Time User Registration FAW Update Unregister Check Register Reset Restart 5 Date amp Time There are two ways of time setting as follow Auto NTP This is to set up local time in case of monitoring from different time zone area Select one of time zone in Time Zone and save User Set This is for user to set up time directly There can be some gaps between local and time of the unit Daylight Saving Time DST Set up the Daylight Saving Time Setup the Begin month week day of week time and Finish month week day of week time after checking the Enable box it will be shifted back one hour during setting per
36. one by clicking the icon Turn ON or OFF the PC s speaker s volume by clicking the icon Turn ON or OFF the PC s microphone s volume by clicking the icon Check if PC s speaker is ON or OFF Check if PC s speaker is ON or OFF Display camera title Display the date Display current time Display the site information such as Day Night Motion Alarm input output ZAI Chapter 3 Network Setting 3 1 Check Network and Installation Type This Chapter is for basic setting regarding Network To install hardware basic understanding of network is required Warning The setting value might be different in accordance with network environment of user s PC Reference Please refer to Appendix for better understanding There are two ways to install hardware 1 Install the camera without IP sharing device 2 Install the camera under IP sharing device which is required PPPoE environment This explanation is based on upon default value of ex factory IP Address 192 168 1 30 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 Caution 1 Check video before installation on Chapter 2 Installation and video check Caution 2 In case using IP sharing device only global IP is available Caution 3 This unit doesn t support PPPoE directly So IP sharing Device is required to connect to the camera lt Installation without IP sharing device gt For static IP refer to 3 2 1 Static IP Setup For dynamic IP refer t
37. r Name O Firmware Update Language Administrator Version HAN AH65 MAL001 V0 02 Network FW AS65 ALLO01 V0 02 00 Web port Active X AH65 V1 0 1 0 HTTP CGI ACGI A001 V0 01 10 ONVIF AVIF_A001 V0 00 10 Update 5 10 System Reset Restart This is the function to restart the camera system Megapixel Network camera For your safety and comfort system Information NA O Factory Default except for TCP IP HTTP DNS amp Restart PAS Factory Default amp Restart Network Web port ES O Factory Default amp Restart DDNS Factory Default amp Restart Date Time User Registration FAW Update O Camera Restart Reset Restart 30 Chapter 6 Stream Information 6 1 Video 1 Image mirror Select a video source mode Normal Flip Mirror Both 2 Resolution Set the video size This camera supports 2 kinds of resolution simultaneously 3 Stream Setting Set the stream This camera supports 3 kinds of stream simultaneously H 264 MPEG4 MJPEG Choose the input source of resolution and codec Supported resolution 1920 x 1080 1280 x 1024 1280 x 960 1280 x 720 1024 x 768 640 x 480 320x240 Supported codec H 264 MPEG MJPEG x The combination of H 264 amp 1920 x 1080 is recommended for broadband network and high performance PC Megapixel Network camera For your safety and comfort Stream Information E Image Mirror Normal v Resolution Input 1 1920x1080 v Input 2 640x480 v
38. ress Rolling Strong Shutter speed is fixed between 1 30 1 40 1 60 and 1 120 automatically depending on the variable light condition Because shutter speed is synchronized with frequency of fluorescent light rolling noise under the fluorescent light is suppressed lt is also recommended in dim indoor environment Suppress Rolling Weak lt works same the way as Strong mode when shutter speed is between 1 30 and 1 120 But when environment is bright to require shorter shutter than 1 120 sec it works the same way as auto mode Under strong fluorescent light this could not suppress rolling noise User Adjust the shutter speed of the camera manually Specify the AGC manually Megapixel Network camera For your safety and comfort Camera Control Day amp Night Color O Shutter Speed White Balance Auto Suppress Rolling 50Hz weak strong Sense Up C User Shutter Speed 1 50 AGC 2 o i Default Save 47 Chapter 9 IP Manager 9 1 Use of IP Manager This program is the utility to find out the unit connected to local network It is useful for the application of the unit connected by DHCP function It can provide you the information such as IP address MAC web port for easy installation and use 9 1 1 Run IP Manager program Double click IP Manager file to open the program Pic 5 1 will be shown IP Manager S LY Select All 2 Select Clear List Clear Mac Address IF A
39. sion F W version and the URL for RTSP connection lt rn Megapixel Network camera For your safety and comfort General Information Camera Name Camera01 Resolution Max 2M 1920x1080 IP Address 192 168 1 30 MAC Address 40 04 0C 01 2B A3 H W Version AH65 MALO01 V0 02 F W Version AS65 ALLOO1 V0 02 00 Stream Connection Stream 1 h 264 1920x1080 rtsp 192 168 1 30 554 stream1 30 Chapter 5 System Information 5 1 Camera Name server title would be shown on the top of the video when you see the video by the viewer Server title is to be English without space Max 10 characters Click Save button to save title after inputting name Megapixel Network camera For your safety and comfort system Information Server Name PS O Server Host Name Administrator Name Camera Network Web port Save DDNS Date amp Time User Registration FAW Update Reset Resta 5 2 Language This is to select language to be displayed in all web pages such as Administrator s page web viewer and main page x Now English and Korean are available Megapixel Network camera For your safety and comfort system Information Server Name Language o Language Admimstrator English Save Date amp Time User Registration r FAW Update Reset Restart ol 5 3 Administrator s ID and Password Change Administrator s ID and password should be English within 20 characters w
40. t Event Information O O E mail E Enable Event Type Y Motion E Alarm input SMTP Server SMTP Port 25 E Authentication User Name Password Sender E mail alarm ipcctvlinkcom ex name company com Message Edit Mail 1 X Receiver E mail 1 ex name company com Subject 1 Message 1 42 7 5 FIP 1 FTP Server To send the recorded video to FTP server upon alarm event Inout FIP server address folder name user IP and password Passive mode Select it if you need to connect in passive mode due to the firewall or the FIP server settings Megapixel Network camera For your safety and comfort Event Information Motion Alarm input O FTP Alarm Output Warm Outpu T Enable E mail ID Password Server Address Directory l Passive Test Save 7 6 Record You can configure the event recording settings so that you can transfer the images stored in the camera to the FTP server if an event motion or alarm input occurs Data send Check to transfer the images to FIP server Recording Stream Choose the stream to record Recording Time Set the recording time point before and after the occurrence of the event Data size limit Specify the maximum data size Megapixel Network camera For your safety and comfort Event Information Motion Alarm Input Event Recording Alarm Output E Enable Event Type Y Motion Y Alarm input Data Send Y FTP Recording Stream Streami v Recording
41. ximum available light at night 5 Equipped with a number of convenient new functions such as OSD Motion detection Privacy ZONE and E zoom 6 Two way audio support 7 This camera adopted PoE that supplies power in addition to data sending and receiving using LAN cable without separate power connection and it provides convenience for users at installation When you connect the camera with PoE and DC adaptor Only PoE is used 1 2 Package Package of products is composed of camera screw User manual software CD see below Please check before starting Installation If there are any missing please contact the shop where you ourchased Caution Please see the package as follows This manual is based on Microsoft Windows XP So there would be the difference according to operating system Camera Quick Guide eee egin VUE 1 3 HOW TO INSTALL 1 3 1 Package Accessories for installation L ANCHOR 6x30 4EA ive SCREW 4x35 TP BIND SUS 4EA HEXAGON WRENCH 3 0mm L TYPE 1EA BOLT 1 4 20UNC L 6 1EA 1 3 2 Installation 1 Make a hole of 25mm in diameter for passing cable 2 Drill four holes on the wall or ceiling and insert the anchors 3 Arrange the cables and fix the screws 4 Attach the sunvisor and fix the sunvisor fixing bolt 5 Loosen the bolt by using the 3mm wrench included 6 Face the direction of the camera to monitor 7 Tighten the bolt to complete adjustment 1 3 3 Co

Download Pdf Manuals

image

Related Search

Related Contents

Micro Innovations AcoustiX  Standard Information Package  Order Entry System Administration Manual    RADIO FM COM LEITOR CD SCD-24 MP3 Manual de Instruções  Volltext  

Copyright © All rights reserved.
Failed to retrieve file