1. Technical Data Sheet Pressure e Temperature Humidity e Air Velocity e Airflow Sound level By Casella Espana c CE Thermostats m Range from 0 to 50 C ambient model from 20 to 80 C duct model and from 100 to 400 C mod le avec bornier Pt100 ou CTN pa RCR relay output 3A 230 Vac power supply 24 Vac Vdc Visual and audible alarm red led in front ABS V0 IP65 housing duct and remote model or IP20 ambient model E TAY 4 turn system mounting with wall mount plate J Housing with simplified mounting system FEATURES OF THE HOUSING Ambient model 41mm 90 mm Duct model stainless steel probe 46 mm 150 mm 90 mm i Material ABS V0 as per UL94 Protection duct model and model with terminal block IP65 ambient model IP20 Display LCD 10 digits Size 50 x 17 mm 6 mm Height of digits Values 10 mm Units 5 mm Cable gland duct and terminal block models For cables 8 mm maximum Weight 162g Cable of remote probe length 2 m and 4 8 mm in PVC different probes available as option TECHNICAL FEATURES Units of measurement Measuring range Accuracy Type of sensor Response time Resolution Type of fluid Operating temperature Storage temperature CF From 0 to 50 C ambient model from 20 to 80 C duct model and from 100 to 400 C model with terminal block Pt10
2. is displayed then NEG meaning that the relay is in negative security it is excited during an alarm condition gt f needed press quickly on the button to switch the relay in positive security the relay is de energized during an alarm condition or a current breaking POS is displayed gt Press 3 s on the button Alarm screen is displayed with On or Off blinking according to the last saved configuration gt Press quickly on the button the display changes from On activated alarm to Off deactivated alarm gt Press 3 seconds on the button to confirm the setting If the alarm is deactivated the instrument displays the measurement if the alarm is activated the instrument displays the following setting e Set the action of the alarm rising edge or falling edge The edge determines the action of the alarm according to the trespassing direction of the threshold s e Rising edge 1 threshold the alarm goes off when the measurement exceeds the threshold and stops when it is below the threshold e Falling edge 1 threshold the alarm goes off when the measurement is below the threshold and stops when it exceeds the threshold e Monitoring 2 thresholds the alarm goes off when the measurement is outside the defined low and high thresholds Rising edge m Falling edge T1 T2 T1 T2 Measurement m gt Threshold S during the time delay T1 Alarm Measurement m lt Thresho
3. 1 corresponds to the time lag before the alarm goes off when the threshold has been reached The time delay 2 corresponds to the time lag before the alarm stops when the measurement is lower than the threshold plus the hysteresis The setting procedure is the same as the rising edge procedure gt In monitoring mode the alarm of the transmitter goes off when the measurement is below the lower threshold and higher the high threshold The time delay 1 corresponds to the time lag before the alarm goes off when the measurement is below the lower threshold and higher the high threshold The time delay 2 corresponds to the time lag before the alarm stops when the measurement is between the lower and higher thresholds The setting procedure is the same as the rising edge procedure The setting of time delays is done the measurement is displayed CONFIGURATION VIA LCC S SOFTWARE option The software allows to set the alarms the thresholds and the time delay of the transmitter 1 2 M To access the configuration via software 3 iE Set the DIP switches as shown beside 4 Connect the cable of the LCC S to the connection of the transmitter Active Switch e Please refer to the user manual of the LCC S to make the configuration The configuration of the parameters can be done either with the DIP switch or via software you can not combine both solutions MOUNTING 37 5 To mount the transmitter mount the ABS plate on th
4. 0 0 5 of reading 0 5 C NTC 0 3 C from 40 C to 70 C 0 5 C outside Pt100 or NTC model with terminal block and stainless steel duct model NTC ambient model and duct model 1 e 63 5 sec ambient 1 e 63 20 sec airtight 0 1 C Air and neutral gas From 0 to 50 C From 10 to 70 C All the accuracies indicated in this technical datasheet were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with calibration compensation PART NUMBER To order just add the codes to complete the part number Example TST Al Thermostat with stainless steel duct probe TST Type of housing Type of probe B terminal block stainless steel A duct probe only for S ambient duct models TECHNICAL SPECIFICATIONS Output 1 RCR relay 3 A 230 Vac Power supply 24 Vac Vdc 10 Consumption 2VA Relay and alarm status Red led in front and internal buzzer Electromagnetical compatibility EN61326 Electrical connection Terminal block for cables 0 05 to 2 5 mm PC communication USB mini Din Kimo cable Environment Air and neutral gases CONNECTIONS Inside the front housing Fixed back housing Removable front face gt 4 MW AET ot ot ane s oe PPETI Saias net an one n Power supply terminal block Relay terminal block LCC S connection Button for Inactive Active settings Cable gland s
5. 75 19 E Casella Galicia casella es com www casella es com Prevencion de Riesgos Laborales Casella
6. e wall drilling 6 mm screws and pins are supplied Insert the transmitter on the fixing plate see A on the drawing beside Rotate the housing in clockwise direction until you hear a click which confirms that the transmitter is correctly installed 75 Ambient model has not any fixing plate 4 fixing holes are inside the back housing Use them to install the transmitter on the required location MAINTENANCE Please avoid any aggressive solvent Please protect the transmitter and its probes from any cleaning product containing formalin that may be used for cleaning rooms or ducts OPTIONS AND ACCESSORIES e KIAL 100A Power supply class 2 230 Vac input 24 Vac output e LLCC S configuration software with USB cable e Stanliess steel Pt100 2 or 3 wires probes or NTC probes for duct models and remote models available on request CASELLA ESPANA S A C Belgrado 4B 28232 Las Rozas Madrid T 34 91 640 75 19 E online casella es com Cataluna T 93 410 16 59 E Casella Cataluna casella es com Castilla y Le n T 661 500 363 E Casella CyL casella es com Levante T 665 325 623 E Casella Levante casella es com Extremadura T 661 500 363 E Casella Extremadura casella es com Pais Vasco T 610 52 58 59 E Casella Paisvasco casella es com Asturias T 985 11 29 19 E Casella Asturias casella es com Andalucia T 687 897 826 E Casella Andalucia casella es com Galicia T 91 640
7. ld S during the time delayT1 Alarm activation activation Measurement m lt Threshold S Hysteresis H during the time Measurement m gt Threshold S Hysteresis H during time delay delay T2 Alarm deactivation T2 Alarm deactivation m Monitoring The alarm goes off when the measurement is outside the low and high thresholds gt Press briefly on the button to select the trespassing direction then press the button more than 3 seconds to validate this direction and set the thresholds e Set the threshold s value The first digit blinks it corresponds to the positive 0 or negative setting of the threshold value Press briefly on the button to select the sign for the threshold value Press on the button more than 3 seconds to validate The second digit blinks press briefly on the button to scroll the numbers Press the button more than 3 seconds to validate Repeat the process until the last digit to configure the threshold value validate the threshold and go to the following setting If the monitoring edge has been selected the transmitter displays the setting of the second threshold e Set the hysteresis The hysteresis is only for the rising edge and the falling edge modes In rising edge mode the hysteresis allows to the transmitter to stay in alarm when the measurement is between the threshold and the threshold minus the hysteresis Ex fora 70 C threshold and a 10 C hysteresis the instrument
8. will stay in alarm when the measurement will be between 70 and 60 C In falling edge mode the hysteresis allows to the transmitter to stay in alarm when the measurement is between the threshold and the threshold plus the hysteresis Ex fora 70 C threshold and a 10 C hysteresis the instrument will stay in alarm when the measurement will be between 70 and 80 C The first digit blinks set it pressing the button briefly several times then press on the button more than 3 seconds to set the following digit Once the hysteresis is set press the button more than 3 seconds to validate and set the time delays www casella es com Prevencion de Riesgos Laborales Casella e Set the time delay 1 and the time delay 2 600 seconds maximum gt In rising edge mode the time delay 1 corresponds to the time lag before the alarm goes off when the threshold has been reached The time delay 2 corresponds to the time lag before the alarm stops when the measurement is lower than the threshold minus the hysteresis Setting procedure Time 1 for the time delay 1 is displayed then the time in second The first digit blinks press briefly on the button and scroll the figures Press on the button more than 3 seconds to validate Repeat the process until the last digit to set the time delay 1 value from 0 to 600 s and validate Time 2 is displayed the the time in second Repeat the process to set the time delay 2 gt In falling edge mode the time delay
9. witch switch Alarm led ELECTICAL CONNECTIONS as per NAC15 100 standard This connection must be made by a NO COM NC 6 7 A qualified technician To make the 1 2 3 4 5 6 7 x connection the transmitter must o K N L not be energized O N L Pe ae Power supply Power supply m Pr Class Il SETTINGS AND USE OF THE TRANSMITTER gt Configuration E E 1 To configure the transmitter it must not be energized Then you can make the settings required with the DIP switches as shown on the drawing below When the transmitter is 2 m configured you can power it up Units setting 3 W E gt Units setting active switch Configurations C F To set a unit of measurement put the on off switch 4 of the units as shown beside in BEO Combinations x gt E sx 4 n www casella es com Prevencion de Riesgos Laborales Casella gt Thresholds configuration The button allows to activate or not an alarm threshold to set the action of the alarm edge to set the threshold s value to set the time delay and to acknowledge the alarm Working principle e By pressing on the button more than 3 seconds you can validate the setting and go to the next setting e By pressing quickly on the button you can increment a value and scroll down the different option or values Setting procedure e Activate or deactivate an alarm gt Press on the button for 3 seconds CONF

Download Pdf Manuals

image

Related Search

Thermostats thermostats thermostats for homes thermostats honeywell thermostats floor electric thermostats smart thermostats meaning thermostats at lowes thermostats at home depot thermostats with remote sensors thermostats programmable thermostats intelligents thermostats for sale near me cheap thermostats for central heating thermostats for sale near me best buy thermostats for sale near me home depot thermostats that auto change heat to cool thermostats for heat pump systems thermostats for homes home depot thermostats mercer cty nj