Home
BTS and CPE Software Upgrade Procedure
Contents
1. Welcome to the SU Web Configuration Server Please use menu bar to configure or get Infomation from device Figure 18 Web Interface Main Menu Click Unit Control at the upper main menu bar the lower menu bar is displayed 5 Click SW Versions Control the SW Versions Control page is displayed Show All Unit Control Registration E BST AL Radio ATPC E Performance Monitor Service Managament EG Show Reset Unit Change Password SW versig SW Versions Control KV 4 6 5 55 app 4 6 5 55 K2_4_6 5 55 app 4 6 5 55 Main 192 1168 254 350 192 168 254 250 K2 4 6 5 55 bz Reset and Run from Shadow Figure 19 SW Versions Control Menu Page Make sure that the current running SW version is 1 2 0 17 or 4 6 5 55 Main SW Version field 6 Enter the appropriate IP address of your TFTP server 192 168 254 250 in the Local TFTP Server IP Address field Enter the appropriate file name of the new software version K2 1 5 1 23 bz for version 1 5 in the SW File Name field Click SW Download and confirm this operation The download operation might take several minutes BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade Show All Unit Control Registration BST AU Radio ATPC Performance Monitor Service Management Logout change Password Configuration Control IMPM Files
2. sn EG BreezeMAX Extreme 5000 BTS and CPE Software Upgrade Procedure Technical Note Software Version 1 5 August 2010 DN1107 BTS and CPE Software Upgrade Procedure Legal Rights Date Document Name Document Number 27 August 2010 BTS and CPE Software Upgrade DN1107 Procedure Written By Daniel Munteanu No of pages 29 Title BreezeMAX Extreme Product Expert Rev C PAN PM Laurian Tintea Product Expert Adrian Stefan Product Expert Team Leader lonel Ghita Rev Date Name A 22 11 2009 Daniel Munteanu First Release 13 04 2010 Daniel Munteanu Updated for 1 5 release 24 5 2010 Update 4 4 CPE Upgrade Using StarACS Copyright 2010 Alvarion Ltd All rights reserved The material contained herein is proprietary privileged and confidential and owned by Alvarion or its third party licensors No disclosure thereof shall be made to third parties without the express written permission of Alvarion Ltd Alvarion Ltd reserves the right to alter the equipment specifications and descriptions in this publication without prior notice No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty Alvarion BreezeCOM WALKair WALKnet BreezeNET BreezeACCESS BreezeLINK BreezeMAX BreezeLITE BreezePHONE 4Motion and or other products and or services referenced here in are either reg
3. Select the Equipment tab click Add and double click the devices to select and add them to the list Extreme BTS 1 2 1 18 10 1 200 10 Up Results on page 2 Total 2 PageSize 1009 4t page 1 of 1 Figure 11 Adding Equipment BreezeMAX Extreme 5000 DN1107 O BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure 1 Create New Task 7 Configure Task 3 Finish Task PM mers Breeze 2 12L18 15 152 12018 10120010 Figure 12 Select Equipment 7 When all the desired devices have been added click Next The Finish Task window is displayed Task Wizard 1 Create New Task 2 Configure Task Finish Action 3 Finish Task none Qrunnow schedule I show runtime results Figure 13 Finish Task 8 Select how and when the task should be run gt None save the task for future usage BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure gt Run Now start the upgrade procedure immediately gt Schedule run the task at a specific time 9 Check the progress of the task by selecting it from the Task Manager Software Upgrade Task In Progress BTSIPE 10 1 200 5 Set as Operational In Progress Ei BTS1PE 10 1 200 5 Load To Shadow Completed Load to Shadow completed BTS1PE 10 1 200 5 Boot From Shadow In Progress CO BTS1PENO 1 200 5 Set as Operational Pending View report Figure 14
4. setup nms Hardware Search version ROB Running SW 1 2 0 1 pevcem gt ar LA Shadow SW 1 2 0 1089 gt Device Settings peak ptime f 160618 gt Advanced View seconds Registration 41 26 2009 12 12 33 PM Device Monitoring Last 11 26 2009 12 12 33 PM File Download Connection Identity File Upload Realm FORLON RPE Serving BS 2 3 3 42 226 1 Device History MAC Address 00 12 CF 54 9E 07 Device Activit Connection y Request URL http 192 168 56 3 56360 goform cpeurl OPending tasks 05 Completed tasks ORejected tasks OFailed tasks Reprovision CPE Figure 28 Device Info Page 4 A window appears informing that the template was created successfully Click OK I Windows Internet Explorer AN Template was successfully created Figure 29 Template Confirmation Window 4 45 Performing Firmware Upgrade for a Group of CPEs 1 Goto the Update Group tab and choose New from the menu list at the left side of the window The New Update Group page is displayed see Figure 29 BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade Ad Ce eae v Update Group FLO TS OE uaa U dat e Gr ou Manufacturer Alvarion gt p p Model name Select model gt Select model i Beceem e View oe e Import Sequans Figure 30 New Update Group Page 2 From the Manufacturer drop down list select Alvarion and from the Model Name select Sequans
5. 1 5 1 23 the intermediate version 1 2 0 3 is mandatory 4 3 After Deployment Over the Air Upgrade Method For this upgrade method you should know the IP address of the CPE If you need to find it out access the BTS to which the respective CPE is associated using one of the following described methods 4 3 1 Finding the CPE IP Address through CLI Connect to the BTS to which the respective CPE is associated using Telnet After logging in navigate to 8 MS gt 1 Show Summary The CPE IP address appears in the MS IP Address line BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS ireezeMiX Extreme Su Version 1 2 1 18 ETS LM GU Di Di HE Ba Radio Channel in Antenna GPS MS Exit oJ mh hA KH ireezeMiX Extreme BTS Si Version 1 2 1 168 MS Show Summary TUUMA YF Concise Concise a Select By MAC S hon By BS DUUMA YF 1 Short HE S hon r in MS Show Surat MS Mac MS IF BS ID Operational 5 Address Addr Of MSs Of MSs Total Number Total Number 19 1 200 10 IO 1 200710 Summary By Bo Connected PRO 5000 CPE Software Upgrade OO 10 e7 41 43 90 10 1 200 61 1 Authorized 1 Total Number Of MSs Connected to BS z Figure 22 MS Show Summary Menu from CLI 1 Login to AlvariSTAR and open the Equipment Manager tab from the Managed Network menu BreezeMAX Extreme 5000 DN1107 BTS and CPE Software U
6. Software Upgrade Using Monitor n nxxernnnnnnnnennnnnnnnnnnnnnnnnnnvnnnnnnnneennnnnnnnnennnnnnnnnennnnn 2 3 3 Software Upgrade Using AlvariSTAR nnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnr 5 3 4 Upgrading the COUNTRY CODES db and RFU HEADS db Files 0006 10 3 4 1 Upgrading the Country Codes ab File cccccccccesseeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeas 10 342 Upgrading the RFU HEADS 00 Filb Luanaeassnmnmsensansnseoneemeneudenesdj 11 4 PRO 5000 CPE Software Upgrade rnnnuennnnvnnnnnvnnnnnvennnnvnnnnnnnnnnvevnnnuennnn 12 4 1 Pre Upgrade Procedure Lm samssamnsnsennnssakapssn aiande 12 AZ DINSCE COMMECCHIC I Method ss issn a aaa 13 4 3 After Deployment Over the Air Upgrade Method ccscccseessseeeseeeenseeeeees 16 4 3 1 Finding the CPE IP Address through CLI rranrrrvennnnnvrrvenrnnnrrrrenrnnnersernrnnnereeenn 16 4 3 2 Finding the CPE IP Address through AlvariSTAR rrnrnnnnvvnnrnnnnnnrrnvrvnnnrnnnnnnnne 17 4 3 3 Upgrade Procedure cccccssccccccccsseeeceeceeeesececcseeeceeesseaseceeseseaeeeesssuaeeeeesesaaass 18 AA CPE Upgrade USING Slar ACS cviiiccteccssictectcccescccsccteiuscectaceesnsdecveesnaqctasceieeweceutestecece 19 4 4 1 E e E E TE E N EE E E E NEA E A T N 19 442 File SENGS sisine Edenia nN ARAN REAT A aN AEA OKRENE 19 BreezeMAX Extreme 5000 DN1107 Gil BTS and CPE Software Upgrade Procedure Contents 4 4 3 Loading Firmware Images to StarA
7. These options are part of the template created in section 4 4 4 The full information of group update is displayed Figure 31 U d t G Manufacturer Alvarion v Activate p ate roup Immediately Model name Sequans v eo Je Version All bd ss e View ime 12 400 A y Name Name is required for the update iis h2 oo i e Import Send to Select x AM z AM zl Amou Klum Period fam am 3 amou Select Devices ning Stop on pause IT File type Firmware Image Select file Select in list Manual Url Figure 31 Full Group Update Window 3 Fill in the following gt Name Enter the Update name free text gt Send to Choose the CPEs to update see detailed instructions in the StarACS User Manual gt Activate Select when to perform the update immediate scheduled etc see instructions in the StarACS User Manual gt Click the Download file tab see Figure 31 and select Firmware Image from the File type drop down list BreezeMAX Extreme 5000 DN1107 6 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade v Activate JU Immediately DE a C Scheduled to T Time 12 po An Period Time v 1 AM AM gt Amount rare Minutes M eee pote TE TATE ron E y ae Pause 4 after Stop on pause M server Local Management LAN Device WAN Device Services WiMAX Operator Profile Actions eye al Fir
8. unit will load a new file into the shadow Do you want to continue N Figure 2 Load to Shadow 4 Check the download process using 2 Show Activation and Status Parameters While the download is still on the status will be In Progress ireezeMiX Extreme BTS 10 SU Version 1 1 0 32 BTS Unit Control sil at Pl He show SW Versions show Activation and amp Load to Shadow et and Run from Shadow Running Version 45 Operational In Progressi Figure 3 Process Status In Progress Upon download completion the status will change to Successfully Completed Also the Operational version will be BreezeEx_1_2_1_18 bzres or BreezeEx_1_1_O_32 bzres if the BTS was running 1 1 version and the newly downloaded image will be available in Shadow The running version will still be 1 2 BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure Operational SW Fi Operational SW W Shadow Sh File Shadow SW Version Running From Operational Operational Boot SW Version 1 0 0 6 Figure 4 Software Versions after Image Download 5 Enter 4 Reset and Run from Shadow and confirm the action After reboot use 1 Show SW Version and check that the new image is used Running From Shadow Operational ST Operational sll ohadotw oi File 5 I Se heres shadow SW Version an Running From Shadow Operational Boot all 4 1 0 0 8 Figure 5 SW
9. CS File System rrrnnrrrnnrrnnnrnrvnvrnnnnnrrnnnnnn 20 4 4 4 Creating an Equipment Template rrrrrrrnnnrrorrrrnnnnnvrnnrnnnnnrrnnnnnnnnrrnnnnnnnnrennnnnn 21 4 4 5 Performing Firmware Upgrade for a Group of CPES rrrnnrrrerrrnnnrrvvvvrnnnrnvrnnnnnn 22 BreezeMAX Extreme 5000 DN1107 Gy BTS and CPE Software Upgrade Procedure scope 1 Scope This document provides the software upgrade procedure of the BreezeMAX Extreme Base Transceiver Station BTS and BreezeMAX PRO 5000 CPE from version 1 1 or 1 2 to version 1 5 2 Upgrade Information E The upgrade procedure for BTS is described in Section 3 E The upgrade procedure for the PRO 5000 is described in Section 4 E When elements are not commercially deployed it is recommended to upgrade the S W through local connection as described in Section 3 2 for the BTS and Section 4 2 for the CPE mH When upgrading an already deployed network the recommended steps are 1 If you are using the NMS system AlvariSTAR StarACS etc upgrade it to latest version not part of the scope of this document 2 Upgrade the BTS using one of the following gt Telnet refer to section 3 2 or gt AlvariSTAR refer to section 3 3 3 Upgrade the subscribers using one of the following gt Direct web connection LAN port of the SU refer to section 4 2 gt Direct web connection over the air refer to section 4 3 gt StarACS refer to section 4 4 3 BTS Software
10. Control Ethernet Op Mode tapp 192 168 254 230 K212 03b Reset and Run from Shadow Figure 20 SW Versions Control Menu Page with Confirmation Window Upon successful download operation the following message is displayed Firmware Download finished 9 Click SW Versions Control at the lower menu bar and then click Reset and Run from Shadow Confirm this operation Show All Unit Control Registration BST AU Radio ATPC Performance Monitor Service Management Logout Show Reset Unit Change Password SW versions Control Configuration Control TM PM Files Control Ethemet Op Mode 192 1168 10254 250 192 168 254 250 42 120 3bz Reset and Run from Shadow Figure 21 Reset and Run from Shadow Confirmation Window x After reset if the radio link is up the new downloaded software version will be set as the main software version In this case clicking Set running version as Main is not required step 10 10 After reset navigate to SW Versions Control page steps 1 to 5 Click Set running version as main BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade 11 If the upgrade software operation has been successful the new downloaded software version is displayed in the Main SW Version field and the previous software version is displayed in the Shadow SW Version field rora In order to upgrade from software version 4 6 5 55 to
11. File 3 RFU Heads file 4 Country Codes File Select File Type 3 Enter TFTP Server IF Address OLSD Enter File Path And File Name RFU HEADS db The unit will download the selected file from the s ected TFTP server For restoring the new configuration in the device a reset is required The reset i3 not part of this operation Do you want to continue Y N BreezeMlX Extreme BTS 10 1 200 10 SU Version 1 5 1 52 BTS5 Unit Control Contiqguration Files Control 1 Upload Configuration File Backup File 2 Download Configuration File Restore Filej 3 Show Activation and Status Parameters Figure 16 RFU HEADS db Upgrade 3 Check the operation status using option 3 Show Activation and Status Parameters 4 Check the new RFU HEADS db file version using the option 2 Show Properties from the 1 BTS menu 4 PRO 5000 CPE Software Upgrade 4 1 Pre Upgrade Procedure Before initiating the CPE software upgrade procedure and depending on the upgrade method follow these steps 1 Connect the CPE unit to the PC only for direct connection method 2 Configure the PC IP Address 192 168 254 250 only for direct connection method 3 Check that you have connectivity with the CPE 4 Check that there is a TFTP server accessible from the CPE e g PumpKIN BreezeMAX Extreme 5000 DN1107 B BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade In order to upgrade from 4 6 5 55 software ve
12. Runtime Results 3 4 Upgrading the COUNTRY CODES db and RFU HEADS db Files When upgrading from release 1 1 or 1 2 to 1 5 it is recommended to upgrade also the COUNTRY_CODES db and RFU_HEADS db files to the latest available version 3 4 1 Upgrading the Country Codes db File Follow these steps to upgrade the COUNTRY CODES db file using the Telnet application 1 Navigate to 1 BTS gt 5 Unit Control gt 5 Configuration Files Control gt 2 Download Configuration File Restore File 2 Select File Type 4 Country Code File and fill in all the other requested data TFTP server etc Confirm the operation BreezeMAX Extreme 5000 DN1107 10 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure ireezeMiX Extreme BTS 10 1 200 10 Si Version 1 5 1 52 BTS Unit Control Configuration Files Control 1 Upload Configuration File Backup File Download Configuration File Restore File 3 Show Activation and Status Parameters foo BTS Unit Control Configuration Files Control Download Configuration File Restore File Select File Type Enter 1 Full Configuration File Services SP MSF File 3 RFU Heads file 4 Country Codes File select File Type g Enter TFTF Server IF Address 10 51 200 1 Enter File Path And File Name COUNTRY CODES db The unit will download the selected file from the selected TFTP server For restoring the new configuration in the device a reset is requi
13. Upgrade Procedure 3 1 Pre Upgrade Procedure Before initiating the BTS software upgrade procedure make sure that you meet the following prerequisites 1 Check connectivity with the BTS 2 Check that there is a TFTP server accessible from the BTS 3 Check that appropriate files are available on the TFTP server BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure When upgrading to version 1 5 under the following circumstances it is mandatory to upgrade x the COUNTRY_CODES db and RFU_HEADS db files to the latest available version m You are using Australia country code 5 8 m You want to enable 5 MHz BW in 5 4 ETSI 5 8 ETSI 5 4 FCC and 5 8 FCC 4 Check there is an AlvariSTAR server reachable form the BTS if AlvariSTAR is intended to be used 5 Perform services and event log backup if necessary When upgrading to version 1 5 it is recommended to first upgrade the CPEs and after that to perform the upgrade procedure for the BTS x Upgrading from version 1 1 or 1 2 to version 1 5 does not affect the already defined services Backup may be useful if anything goes wrong Note that downgrading from 1 5 to 1 1 will result in loss of the incompatible services ETH CS based services 3 2 Software Upgrade Using Monitor 1 The software upgrade procedure is performed using the Software Version Control menu and submenus Navigate to 1 BTS gt 4 Unit Control gt 4 SW V
14. Versions after Reset amp Run from Shadow 6 Use 5 Set Running Version As Operational and confirm the action the software versions should resemble the following figure Operational SW Fi 7 l Bag b res Operational Soll ohadotw oi File ZeEX 2 l hzres Shadow 5W Version Running From Operational Operational Boot S N sior 1 0 0 8 Figure 6 SW Versions after Setting the Running Version as Operational 3 3 Software Upgrade Using AlvariSTAR 1 Login to AlvariSTAR and open the Equipment Manager tab from the Managed Network menu Make sure that the BTS device is in Up State before performing the software upgrade BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure System Managed Network Fault Management Administration Security Management Help vari alvariSTAR T Managed Network e Location Manager SE T E SS mrd ee eee amp Discovery Settings Type Location BTS Number Name TP Address State Runningswver 3 Q GPS Chain Manager RAGGE a A Fault Management a Active Events a Event History a Event Filter Manager Event Template Manager as Script Command Manager bg Event Forwarding NBI Manager dd Administration Task Manager B File Manager Contact Manager License Manager a Security Management P Audit Log Manager pnt User Manager or User Profile Manager w User Session Monitor Resu
15. ersion Control 2 Check the existing software versions using 1 BTS gt 4 Unit Control gt 4 SW Version Control gt 1 Show SW Versions BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure xtreme BTS 10 1 200 10 en show Suricar y Show Properties Configuration Unit Control Fault Management Performance Counters os ie Bl a e Ln xtreme BTS 10 1 200 10 bl Bl a S F kl Om rm BTS 10 1 200 10 Show SW Versions Show Activation and Status Load to Shadow set and Run from Shadow bl Bl a S Hi 3 t Running Version s Operational um Operational Si Operational Si Sion 1 2 1 shadow SW File Breezetx Shadow SW Version en bre 18 Running From Operational Operational Boot all 4 1 0 0 8 Figure 1 Software Versions Check 3 Use 3 Load to Shadow from the Software Version Control menu to point to the TFTP server and the desired software version image BreezeEx_1_5_1_72 bzres is the 1 5 GA version Confirm this action when requested BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure zeMiX Exstreme BTS 10 1 200 10 SW Version 1 2 1 18 BTS Unit Control Sil Show SW Versions Activation and 5 Load to Shadow eset and Run from Shadow Show al 1 Hi Set Running Version As Operational 5 Enter TFTP Server IP ddr Enter File Path nd File Name The
16. istered trademarks trademarks or service marks of Alvarion Ltd All other names are or may be the trademarks of their respective owners WiMAX Forum is a registered trademark of the WiMAX Forum WiMAX the WiMAX Forum logo WiMAX Forum Certified and the WiMAX Forum Certified logo are trademarks of the WiMAX Forum Limitation of Liability a Alvarion shall not be liable to the purchaser or to any third party for any loss of profits loss of use interruption of business or for any indirect special incidental punitive or consequential damages of any kind whether arising under breach of contract tort including negligence strict liability or otherwise and whether based on this agreement or otherwise even if advised of the possibility of such damages b To the extent permitted by applicable law in no event shall the liability for damages hereunder of Alvarion or its employees or agents exceed the purchase price paid for the product by purchaser nor shall the aggregate liability for damages to all parties regarding any product exceed the purchase price paid for that product by that except in the case of a breach of a party s confidentiality obligations BreezeMAX Extreme 5000 DN1107 ii BTS and CPE Software Upgrade Procedure Contents Contents T OCODE e 1 2 Upgrade INIORM AU O Mses aiaa 1 3 BTS Software Upgrade Procedure rnnnnxnnnnnnnnnnnnnnnnnnnnnnnennnnnennnnnennnnnennnn 1 Sk Pee PENNE 445444 1 3 2
17. le Browse Figure 26 File Management Window 4 4 4 Creating an Equipment Template In order to manage groups of CPEs and perform group operations StarACS can use a template profile for the relevant equipment This template profile is created based on one of the CPEs of the same type existing in the system Later on this template is applied to the group of CPEs 1 Goto the Update a CPE tab and select a CPE from which to create a template in the following example Alvarion Sequans see Figure 26 Andaa v Update a CPE GUC CR EO TN SOE Gu Ge Update a CPE Manufacturer Alvarion Model name Sequans v E Manufacturer Model name Serial Created Updated Sti e Search FDevice Info E Alvarion Sequans setup nms 11 26 2009 12 12 33 PM 11 26 2009 12 12 33 PM Device Settings gt Advanced View Figure 27 Update a CPE Window 2 Click the Device Info menu option the information about the device is displayed see Figure 27 3 Click the Create Template button a template is created If there is an existing template you will be prompted to approve the replacement of the old template with the new BreezeMAX Extreme 5000 DN1107 ev BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade MArHVU 39 avaron gt bla Ari v Update a CPE EO EG Se CMCC a T E 2 8 5 3 Info Model j d CPE M name CPE Pro SQ p ate a Desaription Alvarion WiMAX Model CPE Pro SQ Variant Serial Wrist Number
18. lts on page 2 Total 2 PageSize page 1 of 1 gt Equipment Manager Server 10 1 200 200 User admin Figure 7 AlvariSTAR Equipment Manager Window 2 From the Administration menu open the Task Manager tab System Managed Network Fault Management Administration Security Management Help x AlvariSTAR A ton of Equipment Manager X g Task Manager X f Managed Network eee x of Equipment Manager g Location Manager GA Discovery Settings CreatedBy ModifiedBy Volatile Type State LastRun Last Run Result y GPS Chain Manager Faut Management Event History SYSTEM SYSTEM Database Aging Inactive 11 05 2009 14 Completed 11 03 2009 15 i a Active Events Network Scan SYSTEM SYSTEM No Network Disco Inactive A Event History a Event Filter Manager i Event Template Manager wy Script Command Manager Audit LogDAP SYSTEM SYSTEM Database Aging Inactive 11 05 2009 14 Completed 11 03 2009 15 Never run El File Manager Contact Manager License Manager Security Management P Audit Log Manager p User Manager tr User Profile Manager L 4 User Session Monitor Results on page 4 Total 4 PageSize page 1 of 1 gt gt Task Manager Server 10 1 200 200 User admin Figure 8 Task Manager 3 Right click in the opened pane and select New A Task Wizard is displayed BreezeMAX Extreme 5000 DN1107 BTS and CPE Sof
19. mware Image Select in list Manual Not found vi KI j I C Request device to connect Wait for the next device connection Figure 32 Download File Tab and Fields 4 In the Select File section choose manual 5 In the URL textbox enter the IP of the machine the TFTP server is installed on 6 In the Target Location textbox enter the name of the firmware image you wish to download to the CPEs NOTE it needs to be placed in the TFTP server home directory 7 In the File Size textbox enter the size of the firmware image file IN BYTES rounded up 8 Scroll down in the Download File tab and click Save see Figure 33 BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade Version All Scheduled to Date 11 26 2009 Mame fa Time 12 Joo AM Al fam fan amount Send to All h ROS Feet Devices 4 Pause NE ae Stop on pause T Device Info Management Server Local Management LAN Device WAN Device Services WiMAX Operator Profi eheee Fn JAIS MT Wok PMI AJI a File name Mot found Target location G save eee ane KG ap Request device to connect Wait for the next device connection OOOO Cancel Advanced View a MP SELL TPLTLLOT ELE Figure 33 Download File Tab Scrolled Down 9 Select whether the profile is to be activated immediately by selecting Request device to connect or later by selecting Wait f
20. ons BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade E Replace the 192 168 254 251 IP address which is the default CPE IP address on LAN side with the IP address of the CPE on WAN side as found above E The TFTP server should reside in the backbone and should be accessible from the CPE 4 4 CPE Upgrade Using StarACS 4 4 1 General The naming convention of BreezeMAX PRO 5000 CPE within the StarACS system is Alvarion Sequans For detailed description refer to the StarACS User Manual Upgrading a group of CPEs to the required version involves the following steps described in the next sections 1 File Settings 2 Loading Firmware Images to StarACS File System 3 Creating an Equipment Template 4 Performing Firmware Upgrade for a Group of CPEs using the template 4 4 2 File Settings The purpose of this procedure is to set the connections between servers in order to be able to upload the Firmware files to the StarACS system 1 Verify if the FTP and TFTP servers are installed on the StarACS system 2 Login to StarACS and go to Settings gt File Server Fill in the IP address of the StarACS server in the second and fourth sections Download server details and CPE upload server details See Figure 24 BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade AO Ce EO EG TS CMU ies v Settin File managemen
21. or the next device connection 10 Click Save and Activate to activate the group update task BreezeMAX Extreme 5000 DN1107
22. pgrade Procedure PRO 5000 CPE Software Upgrade A System Managed Network Fault Management Administration Security Management Help x 1 AlvariSTAR N A tat gt of Equipment Manager X g Location Manager X Discovery Settings X Task Manager X Managed Network G Equipme gt view Extreme BTS Filter Location Manager amp Discovery Settings IP Address Running SW Ver amp GPS Chain Manager HE A Fault Management a Active Events a Event History aaa Event Filter Manager Event Template Manager Oy Script Command Manager ry Administration g Task Manager a File Manager Contact Manager License Manager A Security Management P Audit Log Manager pnt User Manager ar User Profile Manager w User Session Monitor Results on page 2 Total 2 PageSize Equipment Manager Figure 23 AlvariSTAR Equipment Manager Window 2 Select the BTS to which the respective CPE is associated Select the MS menu The IP address of the MS CPE appears in the IP Address column BreezeMAX Extreme BTS Sector BS 3 Radio Channel Antenna Filter All O es MS Table WAC Address IP Address B5Index SectorD Bandwidth MH 1 1 10 00 10 E7 41 43 90 10 1 200 61 5500 000 Authorized Y awy Figure 24 AlvariSTAR MS Window 4 3 3 Upgrade Procedure The software upgrade procedure is the same as the one described in Section 4 2 Direct Connection Method with two minor modificati
23. red The reset 13 not part of this operation Do you want to continue Y N ireezeMae Extreme BTS 10 1 200 10 Si Version 1 5 1 52 BTS Unit Control Configuration Files Control 1 Upload Configuration File Backup File Download Configuration File Restore File 3 Show Activation and Status Parameters Figure 15 COUNTRY_CODES db Upgrade 3 Check the operation status using option 3 Show Activation and Status Parameters 4 Check the new COUNTRY_CODES db file version using the option 2 Show Properties from the BTS menu 3 4 2 Upgrading the RFU_HEADS db File Follow these steps to upgrade the RFU_HEADS db file using the Telnet application 1 Navigate to 1 BTS gt 5 Unit Control gt 5 Configuration Files Control gt 2 Download Configuration File Restore File 2 Select File Type 3 RFU Heads file and fill in all the other requested data TFTP server etc Confirm the operation BreezeMAX Extreme 5000 DN1107 d BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade BreezeMax Extreme BTS 10 1 200 10 SU Version 1 5 1 52 BTS Unit Control Configuration Files Control 1 Upload Configuration File Backup File 2 Download Configuration File Restore Filej 3 Show Activation and Status Parameters BTS Unit Control Configuration Files Control Pownload Configuration File Restore File Select File Type Enter 1 Full Configuration File Services SP amp MSF
24. rsion to 1 5 1 23 the intermediate version 1 2 0 3 is mandatory In such cases follow one of the below described procedures to first upgrade from 4 6 5 55 to the intermediate 1 2 0 3 version and then repeat the same procedure to upgrade from 1 2 0 3 to 1 5 1 23 4 2 Direct Connection Method Follow these steps to properly upgrade the CPE software version 1 Check that the TFTP server is started and contains in its root directory the software image that you are about to download 2 Open a web browser and go to the following URL http 192 168 254 251 x 192 168 245 251 represents the default IP address of the CPE 3 Login using the appropriate credentials default is installer E K2 Windows Internet Explorer Gr 2 bps 192 168 254 251 Gy favorie ted Stes E Free Hobmal 2 ve er id N Please Enter Password Figure 17 Login Page The CPE web interface configuration main menu is displayed BreezeMAX Extreme 5000 DN1107 13 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade lt gt Winder Inte ret brt Gr Beto 192 168 254 251 Fie Edt View Favorites Tools Helg r Fovorkes Bs Be a diets Show All Unit Control Registration BST AU Radio Atec Performance Monitor Service Management Logout
25. t ftp server details Address frp 92 168 10 21 Settings Username acs Password fi 23456 e ACS and DB Email Server Download server details Address 192 168 10 21 Alerts Username e User Management Password e ACS Users UP File management upload ftp server details Address ftp 92 168 10 21 e Sessions Username acs Password fi 23456 CPE upload server details Address 192 168 10 21 Figure 25 File Server Window 4 43 Loading Firmware Images to Star ACS File System The purpose of this procedure is to upload the Firmware files to the StarACS system and later to use them for the actual CPE upgrade 1 Check if the appropriate Firmware image files are available on the computer you are using to open StarACS For each of the required Firmware images do the following 2 In StarACS go to File Management gt Add Use the drop down menus to choose the following gt Manufacturer Alvarion gt Model name Sequans gt File type Firmware Image 3 Use the Browse button to find the firmware image file and then click Send Update at the bottom left side of the screen The image files are loaded to the StarACS server BreezeMAX Extreme 5000 DN1107 BTS and CPE Software Upgrade Procedure PRO 5000 CPE Software Upgrade iC Ce Ce ac v File Management fu File Management Manufacturer Alvarion p e File Management a Model name Sequans v OG G Mit File type Firmware Image v Select fi
26. tware Upgrade Procedure BTS Software Upgrade Procedure ye A Task Wizard 2 Configure Task name swup 3 Finish Task Description nm Category Software Upgrade Task NE Type Extreme BTS Figure 9 Task Wizard Create New Task 4 From the Category drop down menu select Software Upgrade Task and from the Network Equipment NE Type list select Extreme BTS Fill in a name and a description if needed and click Next The Configure Task window is displayed Task Wizard 1 Create New Task 2 Configure Task Egunment 3 Finish Task Task Name si upgrade Operations File Mame BreezeEx 1 5 1 52 beres Operation Set as Operational ve TFTF Host ies 10 1 200 1 HM External TFTP Server File Management Policy IF Unit is running From Shadow Skip BTS Figure 10 Task Wizard Configure Task BreezeMAX Extreme 5000 DN1107 ao BTS and CPE Software Upgrade Procedure BTS Software Upgrade Procedure 5 In the General tab fill in the TFTP Host IP and the File Name if External TFTP server is selected or select the desired image if Internal server is used from the dropdown menu From the Operation drop down list select Set as Operational and for File Management Policy use Skip BTS When using internal TFTP server make sure that all the desired software images are available under AlvariSTAR HOME filesystem firmware pico folder 6 Select the equipment requiring the software upgrade
Download Pdf Manuals
Related Search
Related Contents
Manuale tecnico - Orsini & Belfatto L PRO SRL BROCHURE 600VA Limo Booklet V1.3 Samsung RS21DCNS Εγχειρίδιο χρήσης descargar la hoja de especificaciones técnicas Copyright © All rights reserved.
Failed to retrieve file