Home
ACDC Pages 177-192 (low res)
Contents
1. ALARM ANNUNCIATORS Monitors potential free input contacts NO or NC 4 to 16 for any change of status Abnormal amp activates one common output relay for audible device with respective flashing LED windows thus indicating the Alarm status This flashing annunciation window is Acknowledged amp Reset when returns back to normal by external push buttons e Powerful Microprocessor Circuit e Fully integrated construction e Optically Isolated input Circuit e NO NC selectable input configuration e Low Power Consumption e AC DC auxiliary supply e Two Window Sizes Big amp Small e DIN standard panel cutouts Built in system watchdog LED Front replaceable windows amp Inscriptions e Super Bright LEDs e Moulded enclosures Z n E ip 14B0S00 416B0S00 12B2SPO 10B4SPO 10B6SPO 26B0SPO Smal Windouno Cutout 20B16S00 28B0S00 312B0S00 4 Points 12B2SPO 68x138 14B0S00 68x138 5 Points 10B4SPO 68x138 6 Points 10B6SPO 68x138 _ 6 Points 26B0SPO 138x138 8 Points 10B8S00 68x138 28B0S00 138x138 12 Points 312B0S00 210x138 14 Points 20B14SPO 138x138 16 Points 20B16S00 138x138 416B0S00 282x138 22 Points 30B22SPO 210x138 24 Points 30B24S00 210x138 624B0S00 2x 210x138 Add supply Voltage A 230VAC B 24VDC Supplied with separate power supply Specifications TEN Printing of Front Replaceable Windows ees olour Re Aux Supply 24 48V DC 110 220
2. LND EV 25 3 Wall 380 x 425 x 360 4 Steps LND1 62 5 5 Wall 390 x 565 x 360 6 Steps LND2 137 5 11 Wall 720 x 565 x 360 6 Steps LND3 200 16 Floor 1150 x 565 x 360 6 Steps Capacitor Modules 440V Single Step for LND1 2 and 3 Base Units Each complete with capacitors contactor fuses neon fuse indicators and plug in connections 3 Step Modules for LND EV only One module completes the system with LND EV JOL 025 25 Ds JOL 05 5 4 1 1 a JOL 10 10 8 2 1 I A eee i JOL 12 5 12 5 10 3 1 a ee JOL 15 15 12 3 9 oo JOL 20 20 16 4 2 r JOL 25 25 20 5 2 ee ee ee ee ee ee EE ee ee E sk a JOLEV 17 5 17 5 14 4 2 5 5 10 3 JOLEV 20 20 16 4 5 5 10 3 JOLEV 25 25 20 5 5 10 10 3 Effective value at 400V Recommended Combinations Many other kVAr combinations can be created to suit application requirements 20 20 5 25 5 10 10 LND EV JOLEV 25 x 1 0 40 41 50 10 20 20 LND1 JOL 10 x 1 JOL 20 x 2 0 50 51 25 62 5 12 5 25 25 LND1 JOL 12 5 x 1 JOL 25 x 2 0 60 57 4 70 20 25 25 LND2 JOL 20 x 1 JOL 25 x 2 3 75 73 8 90 15 25 25 25 LND2 JOL 15 x 1 JOL 25 x 3 3 80 82 100 25 25 25 25 LND2 JOL 25 x 4 3 100 102 5 125 25 25 25 50 LND2 JOL 25 x 5 1 125 123 150 25 25 50 50 LND3 JOL 25 x 6 4 150 143 5 175 25 50 50 50 LND3 JOL 25 x 7 2 165 164 200 25 25 50 50 50 LND3 JOL 25 x 8 0 For external CTs see page 167 For harmonic filters see page 188 Specifications e Supply amp control voltage Vn
3. 2 2 2 6 6 6 User configurable outputs N 1 1 4 4 4 Optional expansion board with user configurable 8 I O EXOM 210 FL EXR Speed sensing from alternator voltage Y Vf Y Y Y Y Speed sensing from magnetic pickup N Y Y Y Y Y 3 resistive sender inputs oil fuel temp N N N Y Y Y Load current measurement N N N Y Y Y Generator Volts measurement Li N L1 N L1 N L L N L L N L L N Mains Volts measurement L L N L L N L L N L L N L L N L L N Earth current measurement N N N M Y Y Exercise at programmed time intervals N N N Y Y Y RS 232 Modbus ASCII Serial communication N Y Y Y Y Y Available for Remote using by PC software N Y Y Y Y Y Standard modem communication N Y Y Y Y Y Generator Power measuring by kVA kW kVAh kWh kVAr kWrh i 4 Event logs N N N Last 50 events Last 32 events Last 32 events Display LED LED LED LCD LED LCD Mains contactor outputs Y Y Y ve Y Y Generator contactor outputs Y Y Y Y Y Y Programmable weekly working permit calendar N N N Y Y Y Maintenance warning working hour or elapsed month N N N Y Y Y Fully Programmable Y Y Y Y Y Y Simple push button controlled operation Y Y Y Y Y Y Automatic Manual Key Start Transfer Switch Controller INSTRUMENTS Automatic engine Start Stop Y Y Y Controls Controls Automatic Shutdown on fault y y y Generator remote start Fuel and stop solenoid condition Load transfer to mains Starter motor Aternatr valage ander pegea gnerlor votagel energon lage Ma
4. Inputs Coolant temp amp oil 4 including pressure pressure with the option of temperature and fuel volume configuring these as digital inputs Config Method None Via front face Via front face Front face or PC via interface Limited front face Fully via type P810 USB programming port Event logging None None None None 250 most recent events Comms Port None None None None Type of events recorded can RS232 or RS485 be selected Fitted with both RS232 and RS485 but only one can be used at a time Multi Menu Access via front panel Status Engine Generator Mains Alarms Event log Serial Port Operator Display First Up Fault Warning Shutdown amp Hour counter warning Backlit LCD scrolling Mains Low oil Pressure active inputs are shutdown amp active Alternator voltage Load Current High Engine Temp signalled by LEDs inputs are signalled by Oil Pressure Engine Temperature Charge fail warning load transfer contactor LED s Load transfer DC Volts Hours Run RPM and Auxiliary shutdown control have a mimic contactor control have Hz Alternator or Mains info LED display a mimic LED display Common Alarm and Scroll Button Mimic LEDs Mode Selection Other Feautres e Modbus RTU IP65 gasket e USB connectivity amp SCADA Engine exercise Schedular Dummy load control plus load shedding up to 5 stages 220 x 160 CANbus Panel Cutout 68 x 68 149 x 109 182 x 137 CANbus None None None A
5. MD synch E01 water or gas pulse programmable 4 x O P load shedding rated for 20mA 30VDC Additional Registers e Target demand e Interlock timer e Load priority setting e Percentage Hysteresis e Override e Load switching frequency Pl Range Profiling Energy Demand Logging Multi tariff Meter IEC 62053 21 ZAP3AM5 P Base Mount 3Ph 4 wire 230 400 230V 400V 5A 1 5 6 Class 1 ZAP3AM100 Base Mount 3Ph 4 wire 230 400 230V 400V 100A 10 100 Class 1 ZAP3AM160 Base Mount 3Ph 4 wire 230 400 230V 400V 160A 10 160 Class 1 Features Billing meter for active Wh and reactive VArh energy demand VA Remote automated meter e Flexible multi tariff TOU billing meter with auto registration reading ready with ZAP EDAT e Profile logging of total energy and average energy demand Lambda Range Logging Energy Demand Logging Multi tariff Meter IEC 62053 21 ZAP3AM5 230V Base Mount 3Ph 4 wire 230 400 230V 400V 5A 1 5 6 Class 1 ZAP3AM5 110V Base Mount 3Ph 3 wire 110V P P 110V 480V 5A 1 5 6 Class 1 Features p e 4 Quadrant billing meter for active Wh and reactive VArh energy demand VA Data storage of last 16 months energy and maximum demand for 4 tariffs e Load profile with integration period 1 5 30 60min Event registration of power outages per phase voltage loss under over voltage INSTRUMENTS e Full multi tariff TOU billing meter with auto registration e Extensive 6 channel logging
6. active kWh import amp export energy e 3 Phase CT and VT connected Meter Low cost no maintenance required e Large Multi function LC Display e Easy Meter Communication via Infrared flag port SSS software included available for download at no sal I zapics Single Phase High Load 100A E Direct Connect JE 1 E Billing N Meter ZAPICS R ZAP1CS BS DINRail 1ph 2 wire 230V 184 275V 100A 10 100 Class 1 1ph 2 wire 230V with ZAP1CS R BS Din Rail RSA Serial Port e Remote automated meter reading ready ZAP1CS R Three Phase Active Energy Meter CT Connected ZAP03DS DIN DIN Rail 3Ph 4 wire 230 400 184 275V L N 5A 1 5 6 Class 1 ZAP03BS BS Base Mount 3Ph 4 wire 230 400 184 275V L N 5A 1 5 6 Class 1 Add 110V for 3 phase system 3PH 3 Wire 88 132V P P 184 275V 100A 10 100 Class 1 kWh Meter Maximum Demand ZAPO3BE MD BS Base Mount 3ph 4 wire 230 400V 184 275V L N 5A 1 5 6 Class 1 Add 110V for 3 phase system 3PH 3 Wire 88 132V P P Features Energy amp Maximum Demand ZAPO3BE MD only Measurement parameters e kWh kVAh kVArh e Data amp Event logging e Watt VAr VA Import Export amp per phase kWandkVA RS232 e Volt Amp Power Factor Frequency e Block amp Moving window e Pulse output e Time of use kWh Meter Maximum Demand Load Management Load Shedding ZAP03LM BS Base Mount 3ph 4 wire 230 400V L N 5A 1 5 6 Class 1 Features As per ZAPO3BE MD plus I O 2 x I P
7. from 32 readings and event recording e Remote automated meter data acquisition via IP or GSM GPRS SMS Accessories ZAP EDAT EDAT g for GSM GPRS AMR at multi meter up to 128 Installations ZAP3AM ZAPICS ZAPO3LM sie a 0 H o 9 B p 9 e EDAT e for Internet AMR at multi meter up to 128 installations ZAP1CS ZAP3AM ZAP SOFT Remit Lite Programming Software CD download for free Can be downloaded from 8 1G si B Bi O D ukwam www zaptronix co za downloads This is for ZAPO3DS ZAPO3BE ZAPO3BS ZAP OPTO Optocoupler RS232 for BS type housing acai ZAP OPTO USB Optocoupler USB for BS type housing soea n ZAP PRO Factory programming for ZAP kWh meters free service Note All 3 phase meters must be ZAP MPS MPS Meter reading amp configuration software Free download from www zaptronix co za programmed before use This is for ZAPO3AM ZAP1CS 182 DPM g gt AGC W DYNAMICS ENERGY SAVING CONTROLLER Geyser Controller with Embedded Microprocessor erea t Geysers are the largest user of electricity in most households using up an to 60 GC 100 geyser controller will save 40 60 of geyser usage GC 100 Technical Info e Immediate saving from first monthly bill Input Voltage 220 240VAC 50Hz _ Features e Ensures geyser is off during peak periods Mounting Din Rail e Back up battery to retain memory e Memory 120 day battery e Override switch geyser off and on e Current Sensor
8. modules a D S E O E E E Modbus Wiring terminal for output input ee G Mode e mii a Wiring terminal for input output Yes power sy ae Digtal Inputs AS20485 Oooo O AA o Digital High Speed Inputs RUN STOP operation switch neee Sa eee ee ee Analog Input analogue presets 6 8 6 4 Relay Outputs VO channels stats indicato rp rte OPL state cestor Run Sop ee Analog Output oero 1 Point 20kHz 2 Points 20kHz Pulse Output DINRaifastener 2 ee ee ee Nex Expansion Module A p Haer Programming Languages n n e Instruction List IL e Function Block Diagram FBD Sequence Function Chart SFC Structual Text ST i Ladder Diagram LD e Continuous Function Chart CFC gt wii fr E Communication Options Expansion Modules LM3210 EDI 8 Digital 24VDC input module LM3211 EDIA 8 Digital 230VAC input module LM3220 EDOT 8 Digital 24VDC solid state output module LM3222 EDOR 8 Digital 230VAC 24VDC relay output module LM3221 EDOT 16 Digital 24VDC solid state output module LM3223 EDOR 16 Digital 230VAC 24VDC relay output module LM3310 EAl 4 Channel Analog input module LM3320 EAO 4 Channel Analog output module LM3401 Profibus DP slave interface module Catalogues amp Manuals LM3403 Ethernet interface module LD3000 LM Micro Series PLC Hardware Manual Accessories LD3001 LM Micro Series PLC Software Manual LS3601
9. separately T HREE PHASE HARMONIC FI 2 5 RTF 2 5 35 RTF 35 5 RTF 5 40 RTF 40 7 5 RTF 7 5 45 RTF 45 10 RTF 10 50 RTF 50 12 5 RTF 12 5 60 RTF 60 15 RTF 15 70 RTF 70 20 RTF 20 80 RTF 80 25 RTF 25 90 RTF 90 30 RTF 30 100 RTF 100 LTERS Harmonic Filters are designed to eliminate the 5th 250Hz harmonic amp higher which can cause damage to three phase capacitors used for power factor correction Standards IEC 289 IEC 076 Tolerance L 3 Thermostat Protection 90 C Heat Insulation Class Class F 155 C Insulation Voltage AkV Maximum Overload 1 17 x In Maximum THD in current 25 Voltage 440V 50HZz Resonance Frequency 189Hz VAREL This compact modular system is both rugged and highly efficient By ordering a base unit the steps required plus an external CT a complete automatic PFC system can be assembled in minutes for fast installation The components can be stocked by PFC specialists and electrical wholesalers for immediate supply from stock There is no need for custom engineering or workshop assembly e Simple ordering assembly and installation for end users and contractors A wide range of systems can be assembled from very few parts e Rugged 440V rated capacitors offer long life e Assembly is simply slide in plug in and go Base Units IP31 Each contains incoming isolator control fuses controller plus terminals for external alarm and CT LND EV LND1
10. 0 30 60 60 60 VM 210 Other standard panels available 240 270 300 330 360 420 480 540 600 and 660kVAr Standard panels include incoming isolator controller protection fuses contactors and capacitor banks 800 x 600 x 400 800 x 600 x 400 800 x 800 x 400 1115 x 800 x 400 1115 x 800 x 400 1575 x 600 x 400 1575 x 600 x 400 1838 x 600 x 400 210 AGC _WW DYNAMICS POWER FACTOR CONTROLLERS rg i A AS 8 8 Capacitor steps Alarm output Y 1 1 Voltage measurement amp supply 10 500 amp 230 10 10 300 amp 230 10 230 400V 380 415V 380 415V Frequency 45 65Hz 50 60Hz 45 65Hz 50 60Hz 50 60Hz Display type LED LED LED LCD LCD Size 96 x 96 144 x 144 96 x 96 96 x 96 144 x 144 External C T x 5A x 5A x 5A x 5A x 5A Programming Auto Man Auto Man Man Auto Man Auto Man Required COS Programmable Programmable Programmable Programmable Programmable Displays RMS voltage amp current Y Y Y Y Y COS V V V V V Output relay step LED LED LED LED LED Alarm displays Y High low voltage High Only High Only Y High low current Y Y Under over compensation V V Y Vv Over voltage current Voltage Only Voltage Only Vv Under compensation Vv Y V Y Current amp voltage distortion V V V 4 Alarm memory 4 E Last 10 conditions Temperature Y Dual Target Coso Y Energy Ratio Alarm Y Harmonic Measurement amp Protection Y RS 485 Communication V Compensation Individual phases
11. 20Amps 8 Pre programmable time periods e Relay output 20A Passive Power Factor Correction Power Factor Correction PFC is a technique of counteracting the undesirable effects of electric loads that create a power factor less than one This range of passive PFC units can save 10 20 of energy consumpion Code Description Technical Info ES15 Single Phase 1000kwh 16A SA plug in type 95 x 56 x 56 Single Phase voltage 220 240VAC 50Hz AD ES100 Single Phase 2000kwh 125x85x60 _ hree Phase voltage 380 420VAC Enorgy Sarer OOOO eee ee oo oo o Operating temperature 60 C max i ES300 Three Phase 6200Kwh 190 x 140 x 70D Sy 53001 Three Phase 10 000Kwh 240 x 190 x 90D i ee saver can be wired either at ES3002 Three Phase 15 000Kwh 240 x 190 x 90D Me DE OE OES Eskom box ACDC l as Note As long as the black ee Features Prolongs life of appliances Tamas meme amy _ is connected to neutral it k amp Stabilise electrical current T Dei dence eA ct Available in single and three phase RAY eR tery E Suitable for home shops offices restaurants etc gations Which phase _ Combination Geyser Power Factor Protection amp Surge Protection Technical Info Combination units consist of both geyser controller and passive power factor Single Phase voltage 220 240VAC 50Hz energy saving These are parallel connection types for single and three Three Phase voltage 380 420VAC phase units some a
12. 20mA 1 5VDC 0 5VDC Output Voltage 0 100 Control System Phase control Constant Voltage Characteristics Output accuracy 1 Benefits Insulation Resistance 500VDC 10g ohms Ambient Temperature 10 50 C Humidity 90 RH below Small si an Di VR1 Min V output Ads mall size saving space Connection Diagram VR2 Max V output Ads e High accuracy and fast response Eliminates contactor noise Sw 1 VA2K r e Extends heater life OFF F amp DIP SW Jute Le e High efficiency no maintenance ho saa 5 IN oND Es E2 e1 RIB RIS TI U e Maintains stable process 1 ON 4 20mA INPUT T U V W temperature N 2 1 OFF VR2K INPUT t E aa Oval ee INPUT OUTPUT E 7 OFF 60Hz
13. 400V For 5mins 528V e Ambient 15 to 35 C e Life expectation is 30 000hrs x e Capacitor rated voltage 440V For 1min 570V Operating temperature 25 D e Maximum over voltage during a 24hr e Maximum over current 1 3 x In Peak 55 C Standards IEC 60439 1 period e Maximum current distortion TDHI Maximum 24hr average 45 C IEC 60831 1 For 8hrs 484V Peak 40 Maximum yearly average Deg 35 C For 30mins 506V Continuous 10 e Loss lt 0 4W kVAr Autonics PID TEMPERATURE CONTROLLERS Universal 4 digit temperature controller Dual indication full PID controller Size H x W 48x 48 Control Relay amp Alarm Relay TZN4S 14R TZ4ST 14R TZN4M 14R TZ4L 14R TZ4H 14R 4 20mA output amp Alarm Relay TZN4S 14C TZ4ST 14C TZN4M 14C TZAL 14C TZ4H 14C 48 x 48 72 x 72 96 x 96 96 x 48 48 x 96 TZ4W 14R TZ4W 14C Control Relay 2 Alarm Relays TZN4S 24R TZN4S 24R TZN4M 24R a TZ4W 24R Features e 2 x 7 digit LED displays PV Process Value RED SV1 Set Point Value GREEN e Measure range multi range and pre scalable Input types TC J K R S T RTD PT100 0 10V 1 5V 4 20mA Connection Diagram for TZN4S Type Supply Volts Code PT100 Code J Code K e SV2 input for oven door interlock e Indicating accuracy of 0 3 F S e Dual PID function selectable fast response PID action PIDF or slow response PID action
14. 400V N re DTSY238 80 3 Phase meter 20 80A 100 4wire 400V N e Power failure memory e Direction of power indication e Anti theft function e Coded card for fraud protection Software requires Windows XP or Windows 7 Fa DDSY P INSTRUMENTS POWER FACTOR METER Digital Power Factor Meter ECR 3 72 72x72 230VAC 10 1 1 digit 0 00 0 99 4 digit 14 2mm high ECR 3 96 96x96 230VAC 10 1 1 digit 0 00 0 99 4 digit 14 2mm high Non flammable enclosure Flush mounting with rear terminals AGC _WW DYNAMICS MODULAR ENERGY METER kWh DIN Rail Mount nes c w tamper proof cw 80ACT ORREIK Operating Temp al terminal seal specu ialaeke 20 to 50 C iis a3 as A 4 alps Pi EET EPT m m oy a i E aa TJA cs Supply Voltage Un 230VAC 230VAC 230VAC 230VAC 230VAC Current I max 5 32 A 40 80 A 5 25 A 5 32 A 10 63 A Operating Current 0 02 32A 0 08 80A 0 02 to 25A 0 02 to 32A 0 04 to 65A Frequency 50 60Hz 50 60Hz 50 60Hz 50 60Hz 50 60Hz Operating Voltage 230VAC 230VAC 195 to 253V 195 to 253V 195 to 253V Power Consumption lt 2VA lt 2VA 0 5VA 0 5VA 0 5VA Precision accuracy class Class1 Class1 Class 1 Class 1 Class 1 Pulse transmission 1000Imp kwh 1000Imp kwh Type SO Type SO Type SO Recorded harmonics Until 7kHz Until 7kHz Until 7kHz Size 1M 17 5mm 1m im 1m 2m 2m 6 1 kWh METERS Digits 5 1 5 1 5 1 j W Wh or 3 Phase 400V N kWh and
15. 5 x 53 CA 14MF 14 35 x 73 CA 3 5MF 3 5 25 x 53 CA 15MF 15 35 x 73 CA 4MF 4 25 x 53 CA 16MF 16 35 x 73 CA 4 5MF 4 5 25 x 53 CA 17 5MF 175 35 x 73 CA 5MF 5 25 x 69 CA 18MF 18 35 x 73 CA 6MF 6 25 x 69 CA 20MF 20 35 x 96 CA 6 3MF 6 3 25 x 69 CA 25MF 25 35 x 96 CA 7ME 7 25 x 69 CA 30MF 30 40 x 95 CA 7 5MF 7 5 30x73 CA 32MF 40 x 95 CA 8MF 8 30 x 73 CA 35MF 35 40 x 95 a et ee ons CA 10MF 10 30 x 73 CA 50MF 50 50 x 100 CACTIME K SOX 7S CA 55MF 55 50 x 100 ae is eas CA 60MF 60 50 x 100 Motor Run Capacitors 480VAC 25 X 59 Motor Start Capacitors 275VAC 30 36 CAR 1 5MF 1 5 CAS 30MF 50 x 85 CAR 2MF 2 25 X 55 CAS 50MF 53 64 50 x 85 Ba CAR 3MF 2 SOOS CAS 100MF 88 106 50 x 85 jw Malissa f i k CAS 125MF 124 149 50 x 85 M OO CAR 6MF 6 39x73 CAS 130MF 130 156 50 x 85 7 CAR 8MF 8 32 x 73 CAS 160MF 145 174 50 x 85 ve i CAR 10MF 10 32 x 73 CAS 300MF 270 324 50 x 110 i i CAR 12MF 12 35x75 CAS 328MF 328 454 60 x 110 i amp CAR 14MF 14 35 x 75 vif CARAG6MF 16 35 x 75 s CAR 18MF 18 35 x 98 H CAR 20MF 20 35 x 98 a CAR 25MF 25 35 x 98 With mounting CAR 30MF 30 40 x 94 stud M8 CAR 40MF 40 50 x 100 CAR 50MF 50 50 x 100 WARNING all PFC systems require protection against harmonics generated by such devices as variable speed drives and UPS s and transient surges including lightning POWER FACTOR CORRECTION CAPACITORS RTR Engergia Technical Characteristics Capacitance tolerance 5 10 Maximu
16. LM PLC amp HMI Programming Software CD LD3002 LM Micro Series PLC Instruction Manual LA3801 COM 300 LM Communication Cable RS 232 Cable 2m HT6101 HMI User Guide LA3810 LM Expansion Module 500mm length LM3101 Complete software amp info HT6100 HMI USB Programming cable HMI101 Complete software amp info HD2100 RS 232 Serial programming cable INSTRUMENTS AGC _WW DYNAMICS kWh METERS Rotating Disc kWh Meters 0142 Authorisation No 0102402 HX12D 40 10 40A HX34D 80 20 80A HX12D 60 15 60A HX34D 100 30 100A HX12D 80 20 80A HX34C CT 5A Size mm 160H x 122W x 126D Size mm 260H x 170W x 135D 6 Digit register Metal Base and Polycarbonate cover Lower bearing is magnetic suspension type Digital kWh Meters Satte et te eel LLT TE ir a a nm a lt a ae amp Mam n eni TERE DDS223 30 DDS223 63 DDS722 100 DTS722 60 100 DDSF223 30 DDSF223 63 DDSF722 60 DSS722 5 60 100 DDS223 30 5 30A 1m 2000 DDSF223 30 5 30A 2000 DDS223 63 5 63A 2m 2000 DDSF223 63 5 63A 2m 2000 DDS722 100 5 100A 3m 800 DDSF722 60 5 60A 3m 1600 DTS722 60 5 60A 6m 320 DSS722 5 1 5 5A CT 6m 1600 1m 17 5mm Wide DSS722 100 5 100A 6m 160 e Pulsed output 3200 Imp kWh Class 1 PRE PAYMENT kWh METERS Aa Pre payment kWh Meters Accessories z DDSY238 60 Single Phase 15 60A 1600 DDSY C Pre payment Card DTSY238 60 3 Phase 15 60A 200 DDSY P Card readers c w program software 4 wire
17. PIDS e Control ON OFF P PI PD PIDF PIDS con trol Connection Diagram for TZN4M O P C 14 7 R co T H113 Sj gn g 18 8 4q liee eol Oers gl ry 15 a l M TEMPERATURE INDICATORS 110 240VAC TA4YI TAYM200K 230VAC Specification Multi volt Supply 100 to 240VAC Consumption 5VA Control Relay output C O 3A 250VAC Sampling time 250ms Connection Diagram for TZ4H Indicator 110 230VAC Add m range 100 200 400 C AGC WW DYNAMICS TEMPERATURE CONTROLLERS Analog Setting amp Analog Setting Analog Setting Deviation Display amp Full Scale Display Thumbwheel Setting amp Digital Display ON OFF Ge Control 7 Sze 9618 E Size 72 x 72 SG 771 z Size 96 x 96 SG 671 z With alarm Range amp Probe Add temperature 100 200 400 or 600 C and Probe type PT100 J or K e g SG 622 400J serre wok Technical specification Control On Off action Connection 2 4 i 5 Sree diagram oe CoM ND upply 110 220VAC Output Relay 1C O A BIB ALARM l CP EON OFF _4 20mMmA Input Thermocouple 5A 250V OKCuoeTtioe OSSAWRAELAY K J and PT100 Hysteresis 2 5 full scale 0 120V 240V NO COM NC Accuracy 1 of full scale Alarm 10 of full scale i o U 3 0 1 Digital ON OFF Control Size 72 x 72mm Probe PT100 VM6251 99 to 999 C Probe J amp K VM6392 99 to 999 C VM6400 99 to 999 C Technical specification Supply 24 or 230VAC Direc
18. V AC LED Amber Green on request ription Potential Free Contacts NO or NC Site Input Configurable Interrogation Voltage 12V DC AL 30 30 x 30mm transparent film Output 1 NO for Audible Hooter Response Time 25m sec 10m sec AL 60 60 x 30mm transparent film Rating 5A 230V AC Resistive Power Consumption 1 5W Window Facia Window Size Big 60 x 30mm Small 30 x 30mm Grouping Trip Non Trip Optional Black letters on transparent film to be Flash Rate Fast 60 Flash Min Slow 30 Flash Min sandwiched between front amp rear difusers Accessories AL 3030 R Red Perspex window 30x30mm c w LED Block AL 6030 R Red Perspex window 60x30mm c w LED Block AL 3030 Y Yellow Perspex window 30x30mm c w LED Block AL 6030 Y Yellow Perspex window 60x30mm c w LED Block AL 3030 G Green Perspex window 30x30mm c w LED Block AL 6030 G Green Perspex window 60x30mm c w LED Block 8 amp 10 Channel Alarm Annunciator e Input contact type NO NC and delays e Remote individual selectable blocking with 0 15 secs are selectable individually on adjustable unblocking delay 0 15 secs all channels e Plug in terminal block for easy service e Two common output relays for siren and DC or AC supply voltage alarm with voltage free contacts Legend can be typewritten on the label Specifications for M4100 2 M1000 easily accessible behind front plate e Consumption 0 15A 2 e Two integrated push buttons for siren Temp Range 20 to 70 C Lid reset lamp t
19. able 1 5m Probe 1 2 Thread 150mm x 5 0 Steel Braided Cable PVC Coated PT100 TC P 100D 100 C TC P S 400 C TC P2 CABLE 200 C PVC coated Grey KSE P KEN P 1 2 Brass Std 1 4 thread TC P4 CABLE 400 C Steel braided CC 02B PT100 TC P 200D 200 C PVC 1 4 Brass PT100 TC PSTEEL 400 C Steel CC 04B Std 1 4 thread 1 2 S Steel TypeJ TC J 400 C Steel TC J S 400 C TC J CABLE 400 C Steel braided KSE J KEN J CC 02S Type K TC K 400 C Steel TC K S 400 C TC K CABLE 400 C Steel braided 1 4 S Steel Specify 1 4 or 1 2 Specify 1 4 or 1 2 CC 04S FRHOMB ERG Temperature Transmitter 2 wire Thermocouple Connectors Code Specification i 29 TRT PT100 Output Signal 4 20mA DC TRT J Power Supply 12 40VDC Female Male TRT K Accuracy 0 15 F S PT100 10 5 FS J amp K FPL PT100 MPL PT100 Add Temperature range PT100 50 100 150 200 400 C FPL J MPL J J 100 150 200 400 600 C a K 100 150 200 400 600 1000 1200 C FPL K MPL K Installation example Fits into Head Type KEN P J or K RHE _ SCR HEATER ELEMENT REGULATORS Voltage Control for Heaters Single Phase 230V SG 027 27A SG 100 100A 100A SG 057 57A yE T SG 132 132A E 160A SG 162 162A 36 160A Three Phase 400V SG 325 16 5 SG 3100 100A 100A SG 350 T 33 m SG 3130 130A 7 160A SG 375 75A 49 75A SG 3160 160A 105 160A Specifications Input Signal 4 20mA 0
20. er supplied RS485 w i o o e l o _ipot __ CANbus Master slave protocol Master slave protocol MODBUS Up to 6 phone numbers up to 1k of user defined messages Up to 8 phone numbers Up to 8 phone numbers GSM 10 PNP 7 ti 8 ee e PNP NPN Digital inputs 2 16 bit 3 32 bit 2 32 bit 2 32 bit High speed input Ea p o p e e a ee oo Analog input E e Thermocouple PT100 _ 6 Mer 10 Relay outputs gt e PNPNP pnp outputs E AON Analog outputs 1 1 5kHz 2K 2 50kHz NPN Highspeed output Up to 64 extra I O via 8 expanders Up to 128 I O extra via 8 expanders I O expansion 8 PNP 24VDC 12 24VDC 12 24VDC Power suppl 96 x 96 96 x 96 218 x 184 260 x 184 Size mm Notes 1 High speed counter shaft encoder frequency measurer of normal digital inputs 10kHz max Can be used as normal digital input 2 10 bit analog input 0 5V 0 10V 0 20mA 4 20mA 3 10 bit analog input 0 10V 0 1mA 4 20mA 4 20mA 4 10 bit analog input 0 5V 0 10V 5 10 bit analog input 0 10V 6 14 bit universal input for thermocouple PT100 0 10V 0 20mA 4 20mA Communication Options Expansion Modules EX A1 Expansion Adaptor RS232 485 Up to 64 1O DI8 TO8 8 Digital Inputs 8 Transistor Outputs d M90 famil CAND amily unig 10 Al4 A02 4 Analog Inputs 2 Analog Outputs f MODBUS lO DI8 RO4 8 Digital Inputs 4 Relay Outputs GSM SMS control y er am fq 10 DI16 16 Digital Inputs e Remote access wi
21. est and alarm accept e Minimum input delay 50ms V Output relay Max 220V AC 2A 8 Channel Annunciator 12VDC AC 30 96x96 M4100 12 Z e Output Max 150mA per channel LED flash frequency Slow Flashing Light 0 8Hz 10 8 Channel Annunciator 24VDC AC 30 96x96 M4100 22 Quick Flashing Light 8Hz 10 10 Channel Annunciator 12 24VDC 144x144 M1000 24 00C e Programming Switches on rear of unit Accessories for M4100 e Reset Lamp Test Via Pushbuttons Power Consumption 180mA Front cover with handle IP54 M0846 00 Front cover with key IP54 M0846 01 INSTRUMENTS Nig ynitronicy Industrial and robotics control MICRO PLCs M90 extended family of PLCs extends to 158 1 0 GSM and MODbus communication with embedded graphic operator panel PLC amp HMI programmed with one programme All models supplied with software instruction manual cable amp connectors gs IP65 when L panel mounted 1 line x 16 characters 8 lines x 22 characters 128 x 64p 128 x 64p a X 64p Resolution Pixels 80 255 HMI displa 15 E 33 No of oe 2048 words 16k words 16k words PLC size Real time clock functions date and time with 7 year battery backup all models Real time clock 256 1024 2048 Coils 256 1024 1600 Registers integers 32 bit integers 64 128 32 bit Timers 64 32 bit unsigned 64 32 bit unsigned Double word 12usec Execution time 1 port 2 ports 2 ports RS232 RS232 485 convert
22. insand generator Manual generator sta stop Load current measurement N 3 Phase 1 Phase eet Preheat Glow Plug Remote Start Stop input Y Y Y Monitors Monitors 3 resistive sender units N N Y 3 Phase mains voltage Engine running time User configurable inputs 2 3 3 Alternator voltage Error Indication User configurable outputs 1 2 2 Program parameters Fail Monitoring Speed sensing off Alternator Y Y Y Low oil pressure Speed sensing off magnetic N y y High t Pickup g emperature RS 232 Serial Comms Y Y Y Over speed failure Remote use from PC Y Y Y Charging fail Standard Modem Comms N Y Y Display LED LED LED Size mm 72 x 72 96 x 96 96 x 96 Size 72 x 72mm Size 72 x 72mm 185 AGC _WW DYNAMICS MOTOR STARTING amp LIGHTING CAPACITORS Specifications e Dielectric material Metalised polypropylene low losses non inductive winding e Case and cover self extinguishing thermoplastic resin Lead 2 x 0 75mm PVC 90 C Reference standards CEI 33 3 VDE 560 8 ASE 1029 VDE EN60252 e Climatic category 25 85 21 e Standard tolerance 5 2 8 e Rated frequency 50 60Hz e Voltage 1 1 Un at 50HZz e Dissipation factor at 20 C V Un 50Hz lt 15 10 4 Lighting Capacitors 250VAC TRE E BA RI DOSH mF I Sia A Soe to Sl a Fo Se CE Supplied with 150mm flying leads and M8 mounting stud CA 2MF 2 25 x 53 CA 13MF 13 35 x 73 CA 2 5MF 2 5 25 x 53 CA 13 5MF 13 5 35 x 73 CA 3MF 3 2
23. kVARh VA Vah or ELF3234 kWh Meter 3 Phase 400V N VAR VARh or C T Ratio selectable by DIP Switch Indication Active and Reactive PF Power Selectable Primary CT Current 5 10 15 20 25 30 40 50 60 75 80 100 120 150 200 250 300 400 500 600 750 800 1000 1200 1250 1500 7 Digit Electro mechanical display e Accuracy 2 kWh W Wh PF or 3 KVARh VA Vah PF or ELF3234 3 1600 2000 2500 3000 4000 5000 6000 VAR VARh PF e 7 Digit Electro mechanical display e Accuracy 2 e Pulsed Output V A F ELF3259 Digital Power kWh Meter kWh neieator K RE Inputs V 110 or 400VAC Range 80 500V Supply Voltage Un 230VAC 3 Phase 4 Wire Current I max CT 5A Input 1 1A or 5A programmable Operating Current 60 100 150 250 Supply Volts 80 270VAC 3VA pe PRAP a Accuracy 2 for VARh ee All others 1 Frequency 90 60Hz e Phase wise amp total RMS for power total for Operating Voltage 195 to 253V Energy Meters i 10 year back up of integrated data kW a SUSU ab VA function selectable 3D or Arithmetic eee Size IM 17 5mm 2m V shows all Line Line Line Neutral 0 99kW Indicator Digits 3 Individual amp Average Voltages c w 16A Plug amp Socket e Size 96 x 48 x 40 D mm Ideal to check your kW usage from generator etc 181 INSTRUMENTS ACDC Z ptronix _WW DYNAMICS kWh METERS Zaptronix kWh Meters Features Billing meter for
24. ll controllers are suitable for 12 or 24V DC systems For remote real time diagnostics and telemetry Tia including SMS communications PSTN or GSM modem not included USB Interface Module c w cables and software for programming Model 720 Autonics ROTARY ENCODER Coupling 40mm Shaft type encoder 50mm Shaft type encoder Incremental Type Incremental Type lype Totem Pole Output HTL E40S6 3 1 12 24VDC E50S8 3 1 12 24VDC V NPN N O Output TTL E40S6 3 2 12 24VDC E50S8 3 2 12 24VDC W Line Driver Output TTL E40S6 6 L 5VDC E50S8 6 L 5VDC _ Pulses Revolution Add to code 100 360 500 1000 1024 Add to code 50 100 200 250 360 1000 1024 1800 2500 3600 F Specifications Shaft Toter Pole Outout Low Load current Max 30mA Residual voltage Max 0 4V P High amp Load current Max 10mA Output Voltage Min 1 5V NPN Open Output Load Voltage Max 30V Load current Max 30mA Residual Voltage Max 0 4V Low Load current Max 20mA Residual Voltage Max 0 5V Seat uve High Load current Max 20mA Output Voltage Min 2 5V Max Response Freq 180kHz 184 DPM EAOM 19 EAOM 9F EAOM 210FLS EAOM 2FDS MESSENGER with GSM Size mm 2X T2 96 x 96 144 x 204 x 37 144 x 204x37 144x 204x37 144 x 204 x 37 Automatic engine start stop and load transfer Y Y Y Y Y Y Manual Automatic and Test Mode control Y Y Y Y Y Y User configurable inputs
25. m THD in Voltage 90 Frequency 50Hz 60Hz on request e Maximum THD in Current 25 Temperature Range 40 C 55 C Discharge Resistance Incorporated Dielectric Losses lt 0 5 W kVAr Dielectric Metalized polypropylene film Maximum over voltage 1 11 x Un Voltage test between terminals 2 15 x Un 2sec Maximum over current 1 5 x In Fuse ratings to be 1 5 to 1 8 times the nominal capacitor current Voltage test terminals to case 3kV for 10 sec AC e Standard EN60831 1 2 Cylindrical 3 phase power factor capacitors Ideal for use with harmonic filters e Terminals clamp type Mounting via stud 440V 1 0 8 1 3A 2 5mm 70 x 215 C440 010 Overpressure disconnection 440V 1 5 1 2 1 9A 2 5mm 70 x 215 C440 015 e Discharge resistors fitted 440V 2 1 5 2 5A 2 5mm 70 x 215 C440 020 Manufactured to EN60831 1 2 440V 2 5 2 3 2A 2 5mm 70 x 215 C440 025 440V 3 2 5 3 8A 2 5mm 70 x 215 C440 030 440V 4 3 5 0A 2 5mm 70x215 C440 040 440V 5 4 6 3A 2 5mm 70 x 215 C440 050 440V 7 5 6 9 7A 6mm 85 x 215 C440 075 440V 10 8 5 13A 6mm 100 x 215 C440 100 440V 12 5 10 5 17A 6mm 100 x 215 C440 125 440V 15 13 20A 10mm 100 x 300 C440 150 440V 20 17 26A 25mm 120 x 300 C440 200 440V 25 22 33A 25mm 120 x 300 C440 250 440V 30 26 39A 50mm 136 x 300 C440 300 440V 35 29 46A 50mm 136 x 300 C440 350 440V 40 36 58A 50mm 136 x 300 C440 400 440V 50 45 66A 50mm 136 x 300 C440 500 550V 5 2 64 3 73A 4mm 70 x 215 D2800 550V 7 5 3 97 5 59A 4
26. mm 85 x 215 C550 75 550V 10 5 29 7 46A 4mm 85 x 215 C550 100 550V 12 5 6 61 9 32A 4mm 100 x 215 C550 125 ie 550V 15 7 93 11 19A 6mm 100 x 215 C550 150 Se 550V 20 10 58 14 91A 6mm 100 x 300 C550 200 ie 550V 25 13 22 18 64A 10mm 120 x 300 C550 250 gt 550V 30 15 87 22 37A 10mm 120 x 300 C550 300 eo 550V 40 21 15 29 83A 16mm 136 x 300 C550 400 gir 550V 50 26 44 37 28A 25mm 136 x 300 C550 500 3 Phase Capacitors Steel enclosed type 440V 5 4 6 5A 2 5mm 300 x 115 x 115 R0440 050 Ideal for use 440V 7 5 6 9 7A 4mm 300 x 115 x 115 R0440 075 with harmonic 440V 10 8 5 13A 4mm 300 x 115 x 115 R0440 100 LOE naa 440V 12 5 10 5 16A 6mm 300 x 115x115 R0440 125 stud type 440V 15 13 20A 10mm 300 x 115 x 115 R0440 150 Discharge 440V 20 17 26A 10mm 425 x 165 x 150 R0440 200 resistors fitted 440V 25 22 33A 10mm 425 x 165 x 150 R0440 250 440V 30 26 40A 16mm 425 x 165 x 150 R0440 300 Manufactured 440V 35 29 46A 16mm 425 x 165 x 150 R0440 350 to EN60831 1 2 440V 40 35 52A 25mm 425 x 165 x 150 R0440 400 440V 45 38 58A 25mm 425 x 165 x 150 R0440 450 440V 50 44 66A 50mm 425 x 165 x 150 R0440 500 440V 60 52 79A 70mm 425 x 320 x 150 R0440 600 440V 70 60 92A 70mm 425 x 320 x 150 R0440 700 440V 80 70 105A 95mm 425 x 320 x 150 R0440 800 Automatic PFC Panels 400V 20 20 20 VM 60 20 20 30 VM 70 10 20 30 30 VM 90 20 20 30 30 VM 100 30 30 30 30 VM 120 30 30 30 60 VM 150 30 30 60 60 VM 18
27. t Reverse PWM amp Input Thermocouple K J amp PT100 Neutral zone operation Accuracy 1 of full scale Output Relay C O 8A 250V e Min Max Alarms Differential or Hysteresis programmable Connection diagram Probe E Z 7 ae momo Ela When using 2 wire PT100 Probe short circuit terminals 4 and 5 Transparent cover for 72x72 Adaptor for 72 x 72 to 96 x 96 VJ4458 For blind temperature controllers see page 67 Digital 1 Set Point Digital 2 Set Point Thumbwheel 1 Set Point Analog 1 Set Point 72 x 72mm 48 x 48mm a 48 x 48mm 34 x 76mm VM6269 99 to 999 C TP 48 P 100 200 400 C TR 48 P 100 200 400 C MTR11 150PTC TP 48 J 200 400 C TR 48 J 100 200 400 C TR 48 K 100 200 400 C Reversed 8 pin P3G 08 Connection diagram H L m 5 TP 48 K 200 400 C All supplied complete with Y 50 mounting bracket Specifications Supply voltage 110 240VAC Hysteresis 2 5 full scale Relay output 1 C O 2A 250VAC Panel mount or 8 pin plug in Supply 230VAC CW Probe Range 50 150 C Spare Probe PTC150 E a0 _ Supply 4 s a a a TP AGC _WW DYNAMICS TEMPERATURE PROBES selina Upes NOTE Wire Colours K White amp White with Red Stripe E vldis amp White with Yellow Stripe PT100 2 x White 1 x Red TEE size 100mm x 5 0 oo Di 1 5m Prone size 100mm x 5 0 Thread size 1 4 or 1 2 Cable 1 5m C
28. th any Note when using expansion modules lO TO16 16 Transistor Outputs phone line modem expansion adaptor must be installed 1O RO8 8 Relay Outputs EX90 DI18 RO8 8 Digital Inputs 8 Relay Outputs lO PT4 4 PT100 Inputs 42 to 112 C So parite q One Accessories vi O L Windows based OPLC GSM K1 GSM modem magnet antenna cables and adaptors pls program for both M90 19 R4 RS232 to RS422 485 converter TEE PLC amp HMI V200 19 ET1 Ethernet module for PLC V230 amp V260 only For power supplies see page 69 E HollySys LM MICRO SERIES PLCs The Lm Micro Series PLC is comprised of various modules The basic functional configuration requires a CPU module working as a basic unit in comple ment with optional expansion modules such as communication modules digital 1 0 modules and analogue 1 0 modules NG Y S S s F F F F Vv Vv Vv Vv Vv 24VDC 240VAC 24VDC 240VAC 240VAC 21 28VDC Power Suppl 125 L x 90 W x 70 H mm 50 L x 90 W x 70 H mm 192 x 138mm 224 x 161mm Size Unlimited number of counters 15 bits counting range 42 bt AID 320x240 640x480 Resolution Unlimited number of timers 1ms to 49days 10 000 000 Open Close 10 000hrs Timers Lifespan 0 37us per instruction 200mHz RISC Excecution time Real time clock function 10 years back up E S Real Time Clock 60 000 words 65535 words 128k Words PLC Program Size 1 1 11 1 fp RS232 Connections Ce are RS485 Connection to expansion
29. timated CO emission produced Add 2 x Current Sensor AML CS AML 1208 Transmitting frequency 433mHz with proprietary communication coding for different scriptior market segments AML CS Current Sensor ES100 2GC SS Single phase power 2 x Geyser Surge protection 170x 200x 85MM Wiets Red Phass Sexi sige of Geyser 06 OS S OO S C We or green Yellow Pi ES300 GC Three phase power Geyser controller 210x215x100mm ee ne wre i apie tha eitoyeer ES300 GC SS Three phase power Geyser Surge protection 3ph N 210 x 215 x 100mm Black Wire r BASTO INSTRUMENTS faCi dC T NMWe DYNAMICS DEEP SEA ELECTRONICS GENSET CONTROLLERS Manual Start Stop AMF Application i AMF Relay outputs Fuel and Start solenoid Fuel on Crank Fuel Crank Mains amp Fuel Crank Mains amp Standard Gen Controller Common Alarm 2 x Configurable Alt Contactor Alt Contactor Outputs Low oil Pressure 2 x Configurable 2 x Configurable 4 x fully Configurable Digital inputs High Engine Temp Low oil Pressure Low oil Pressure Low Oil Pressure High Engine Temp Standard Gen Controller Auxiliary Shutdown High Engine Temp High Engine Temp Emergency Stop Remote Start 3 Inputs Charge Fail Auxiliary Shutdown Auxiliary Shutdown attempt or Mains Stimulation 8 fully Configurable 2 Configurable 2 Configurable Charge Fail D 2 Configurable Analog inputs None None None 2
30. vailable fitted with surge protection Surge Protection 65kA ES100 GC Single phase power Geyser controller 170 x 200 x 85mm ES100 GC SS Single phase power Geyser Surge protection 170 x 200 x 85mm pm ES300 2GC SS Three phase power 2 x Geyser Surge protection 3ph N 210 x 215 x 100mm WIRELESS POWER DISPLAY UNIT Se j JELENA LE set pil BEEN tia e e AL With the standard electricity In Home Display unit you can clip the current sensor around the electricity meter s live feed supply such that it measures the total electrical power entering your home or office Power consumption will be recorded and transmitted to the display unit wirelessly The following features are provided also Dual battery system is used to extend operation period and to prevent data lost during battery changing e Indicate existing cost alert level by Tri color LED e Display temperature and current time 1 Phase Monitoring System e Clock alarm and cost alert level setting Kit D intiol e Monitor up to 8 sensors Support gt 30m RF transmission Kit Description AML 1208 1x Current sensor 4 x Batteries e 1 x Sender unit e 1 x User Manual This product is a semi portable communication product used in the household market 1 x Display unit 1x Desk Stand You can view the instant electricity consumption cost up to current hour and records 3 Phase Monitoring System eg hourly daily weekly and monthly as well as es