1. LJ Fess SxS I a L nergie Sans Limite Safe Energy for Life EEEE LLL LLL LLL On Line Double Conversion Rack mount UPS The ideal solution to effectively protect your critical systems and industrial environments The E6 LCD RT EVOLUTION range relies on microprocessor control technology intended in LCD RT particular for users of critical systems that require reliability availability and high performance at the same time telecommunications equipment critical Evolution ap l i industrial applications etc From 1 to 10 kVA High Performance and reliability E6 LCD RT Evolution offers your connected devices a high level of protection against overvoltage overload and short circuits Ry mD e Qutput power factor of 0 9 pA CVA e Up to 3 operating modes Normal Eco and Advanced Eco efficiency up GARNW to 98 e Programmable outlets enabling different groups of loads to be easily and independently controlled models up to 3 kVA e Connector for emergency stop EPO CPAU function ensuring the safety of FR LOO AT Cvelntion from 4 6 3 A personnel and equipment in the event of an emergency io i il EERE EEEE On Line Double Conversion Technology Compatible design The practical and versatile E6 LCD RT Evolution is designed for simple installation Its compact 2 in 1 design fits easily into a variety of environments horizontally in a patch bay with attachment brackets included or vertically in
2. tower with its base included A reinforcing attachment rack kit option is recommended to secure UPS devices in unequipped patch bays Rack Tower convertible Redundant parallelizable The most reliable of technologies The On Line Double Conversion technology delivers a perfect sinewave output current and provides thorough and effective protection of critical devices LCD control screen Parallel installation E6 LCD RT Evolution an ideal solution for data centres from 5 kVA upward can connect up to 3 UPS devices in redundant parallel mode N X and thus increase the capacity up to 30 kVA Remote control software Aa Essential advantages Wm e Warm swappable batteries enable an uninterrupted supply to critical and key loads during maintenance work e Audible and visual alarms to warn in event of a problem Extended backup e Cold start function if there is no mains power time possible e UPS automatic restart when mains power restored see models concerned below www infosec ups com AVANTAGES Power factor of 0 9 e Optimal output power factor 0 9 NB 0 8 for models from 1 to 3 kVA e High performance e Efficiency for critical applications Energy Saving ECO Mode Efficiency of up to 92 from 1 to 3 kVA and 96 for powers from 5 to 10 kVA reduce energy consumption and costs This operating mode delivers a static bypass power supply and offers timely return to on line d
3. Administrator Monitored UPS jia yi nbven vol corp gt USB id FA67EAC POI CONNECTION A connector tailored to industrial environments E6 LCD RT EVOLUTION 1000 S amp 20008 E6 LCD RT EVOLUTION 3000 5 8 USB communication port 9 RS 232 communication port 3 Standards protected UPS outlets 16A protection 10 SNMP intelligent slot 4 AC input cable 1000 VA 10A 2000 and 3000 VA 16A 7 EPO Emergency Power Off 11 External battery connector S models only 1 Programmables protected UPS outlets 10A 5 Input breaker 2 Standards protected UPS outlets 10A 6 Network Fax Modem surge EG LCD RT EVOLUTION S from 5000 to 10000 VA Battery pack from 5000 to 10000 VA 1 RS 232 communication port 5 Parallel port 2 8 External Battery connector 2 USB communication port 6 SNMP intelligent slot 9 Input circuit breaker 3 EPO Emergency Power Off 7 EMBS External Maintain Bypass 10 Input Output terminal 4 Parallel port 1 Switch port 11 Battery pack output circuit breaker OPTIONS SNMP agent AS 400 dry contact card The use of SNMP agent with EG LCD RT EVAN UPS devices makes it easier The AS400 communication card supplies dry contacts to feedback alarms from your to manage the UPS due to its many special features UPS e g centralized technical management e Connection to the Ethernet network and identification by IP address e Low battery detection e Configuring and programming
4. TECHNICAL OUTPUT CHARACTERISTICS 110 115 120 127 VAC Voltage or 208 220 230 240 VAC 200 208 220 230 240 VAC AC voltage regulation Batt mode Frequency range Synchronized range 50 Hz 47 53 Hz or 60 Hz 57 63 Hz 50 Hz 46 Hz 54 Hz or 60 Hz 56 Hz 64 Hz Low voltage 176 VAC 154 VAC 132 VAC 110 VAC 2 range High voltage High Line transfer rongo High Line comeback Frequency range Power factor 50 Hz 0 1 Hz or 60 Hz 0 1 Hz Harmonie diccarcion lt 2 THD linear load lt 2 THD linear load lt 4 THD batt mode before shut down lt 4 THD batt mode before shut down T Pure sinewave 3 3 10A Output outlets IEC standards programmables TOA TAIPA 1 standard Terminal board 4 10A 4 10A 16A EFFICIENCY BATTERY Number E a Standard model 7 hours recover to 90 9 hours recover to 90 capacit capacit 1A Depending on the capacity of external batteries time model S DISPLAY LCD screen __ O Loadlewel Battery level AC mode Battery mode Bypass mode and Fault indicator AUDIBLE ALARMS Sounding every 4 seconds Sounding every second Sounding twice every second Continuously sounding Battery mode Low batter Overload MANAGEMENT COMMUNICATION USB amp RS232 port and Infopower included software support Windows family Linux Unix and MAC Optional SNMP Management system through SNMP software VMware compatible and web browser Parall
5. switch off and restarts of the system on a weekly or other basis e UPS configuration locally or remotely e Self diagnosis of the UPS devices while operating e Automatic shutdown according to pre defined priorities on network PCs e Sending warning messages to users of the network mail GSM etc e Events log Depending on the applications dry contacts may normally be open or closed Isolation Transformer solution Transpormer provides isolation between the input and output current External maintain bypass switch EMBS for E6 LCD RT EVOLUTION UPS devices from 1 to 10 kVA Backup extensions e Provides continuous power to connected equipment during Opportunity to increase battery power for maintenance of the UPS via a rotary switch unstable or highly disrupted environments The versions extended backup time are delivered without an internal battery but with external battery packs Rack kit Enables securing to a patch bay e Provides a large number of outlets for extended use e Rack or Tower model depending on the working environment 1 to 3 kVA e Simple installation plug and play for models from 1 to 3 kVA e Available for all UPS devices from 1 to 10 kVA Es PASS NORMAL lt ee ee TECHNICAL CHARACTERISTICS A PEFC 10 31 1614 Cette entreprise a fait certifi
6. 4700 ORVAULT FRANCE Sales Contact Tel 02 40 76 11 77 commercial infosec fr www infosec ups com rks or registered trademark of Infosec Communication All other trademarks or registered trademarks belong to their respective owners Photos ration may vary depending on the temperature battery condition and peripherals added UPS are part of electronic and electric
7. e power down to 80 of puissance nominale when the output current is adjusted at 100V 200V 208V Number of batteries can be adjusted from 18 to 20 2015 Infosec Communication SAS all rights reserved Infosec UPS System is a trademar are not binding Specifications are subject to change without prior notice Backup time is only a guide actual du equipments category At the end of their lives they have to be collected separately 12 14 AA 80 111 41 LCD RT Evolution From 1 to 10 kVA Package content 1 UPS 1 USB cable 1 RS 232 cable 1 input cable 1 to 3 kVA models 4 IEC 10A output cable 1 to 3 kVA models 2 19 Rackmount Bracket 1 floor standing system 1 user manual Infopower Software 2 cables for parallel ports gt 5kVA 1 battery cable gt 5kVA Options Rack kit Ref 61429 SNMP card Ref 61424 Dry contact card Ref 61454 RS 485 card Ref 61439 External Maintain Bypass switch 61442 61444 Additional Battery banks until 30 minutes backup time depending on the connected load Isolation transformer Isolation transformer for 5 and 6 kVA 67146 Warranty Two year warranty against manufacturing defects under normal conditions and compliance with precautionary measures GA Warranty to be taken out on www infosec ups com within 10 days of purchase Infosec Communication 4 rue de la Rigotiere 4
8. el connection O eee Parallel port 20 90 relative humidity 0 40 non ideal environment 0 95 relative humidity 0 40 non condensing condensing Up to 1000 m above sea level gt 1000 m 1 deterioration for every 100 m g Operating Altitude _ Operating Altitude Less than 50dBA 1 meter Less than 58dBA 1 meter Less than 60dBA 1 meter SAA 163W 257W 416W Heat dissipation max M 110M 556 31 Btu h 877 13 Btu h 1419 80 Btu h o fe fee En 141 W 256W 348W 600W 600W 600W 600W Heat dissipation max HV 230 V 481 11 Btu h 873 5 Btu h 1187 41 Btu h 2047 8 Btu h 2047 8 Btu h 2047 8 Btu h 2047 8 Btu h CE RoHS EMC Electromagnetic compatibility EN 62040 2 2006 Low voltage Safety EN62040 1 2008 SALES INFO Communication CE RoHS cTUVus EN 62040 2 2006 EN62040 1 2008 UL 1778 R 2006 CSA C22 2 NO 107 3 05 R 2006 2 years 3700085 67113 9 3700085 67114 6 3700085 67115 3 3700085 67119 1 3700085 67120 7 3700085 67121 4 3700085 67122 1 3700085 67116 0 3700085 67117 7 3700085 67118 4 3700085 67123 8 3700085 67124 5 3700085 67125 2 3700085 67126 9 Gencods standard versions Gencods Long backup time version S LV 110V and HV 230V products are different Reduction of the power down to 95 of puissance nominale when the output current is adjusted at 115V Reduction of the power down to 90 of puissance nominale when the output current is adjusted at 110V Reduction of th
9. er sa cha ne de contr le pefc france org E6 LCD RT EVOLUTION 9000 S E6 LCD RT EVOLUTION 6000 S E6 LCD RT EVOLUTION 8000 S E6 LCD RT EVOLUTION 10k S E6 LCD RT EVOLUTION 1000 S E6 LCD RT EVOLUTION E6 LCD RT EVOLUTION 3000 S GENERAL CHARACTERISTICS Technoloc On Line Double Conversion Power VA 1000 VA 2000 VA 3000 VA 5000 VA 6000 VA 8000 VA 10000 VA 900 W 1800 W 2700 W 4500 W 5400 W 7200 W 9000 W Long Backup time S 800 W 1600 W 2400 W 4500 W 5400 W 7200 W 9000 W Standard Long Backup time S 08 O PHYSICAL CHARACTERISTICS Dim D x W x H mm 415 x 440 x 88 515 x 440 x 88 635 x 440 x 88 580x440x133 3U 668x440x133BU Dim D x W k HUDU 580 x 440 x 133 3U 580 x 440 x 133 3U Battery bank Net weight kg UPS Battery bank 12 9 20 6 17 57 20 63 Dim D x W x H mm a a ae ie ie ae ME E L A Power factor Standard Long Backup time S TECHNICAL ee CHARACTERISTICS 110 V 80VAC 70VAC 60VAC 55VAC 5 gt S o O Low Line transfer based on load percentage 100 80 80 70 70 60 60 0 Low Line comeback 160 VAC 140 VAC 120 VAC 110 VAC 5 110V 85VAC 75VAC 65VAC 60VAC4 5 S o O 230 V 170VAC 150VAC 130 VAC 120 VAC 5 186VAC 164VAC 142 VAC 120VAC 2 110V ISOVACH 5 o o 230V 300VAC 5 Jo BVA O 110V 140VAC 5 S o 230V 290VAC 5 J VAC Single phase 0 99 at 100 load
10. nternal operation Communication e USB or RS 232 ports enable communication between the UPS and the various stations and IT servers they are protecting e SNMP agent optional EPO emergency stop control e This function ensures the safety of EPO personnel and equipment in the event of fire or any other emergency situation by initiating ans o a total and immediate shutdown of the UPS Cold start function e t enables an emergency situation involving a total power cut to be overcome by starting the UPS using batteries if there is no mains power supply Batteries Adapted battery cabinets Other battery cabinets can be added to increase backup time Intelligent battery chargers to optimise battery performance A battery charger from 1 to 3 kVA with 2 levels reduces charging time and adjusts the charging voltage according to the outside temperature to increase the lifetime of batteries and thereby generate energy savings Advantages of models from 5 to 10 kVA Parallel installation option to connect up to 3 UPS devices in redundant parallel mode N x Battery chargers UPSs upward of 5 kVA are fitted with extendable chargers with 3 leve optimising battery performance as well as their recharge time extending their useful life even further In addition due to an exten design a charger can be connected in parallel as needed there offering a greater battery charge capacity User type
11. ouble conversion if required The E6 devices from 1 to 3 kVA also have an Advanced Eco mode that provides up to 98 efficiency User friendly LCD display e Accurate and user friendly LCD screen displays status and parameters in real time e Intuitive and multi directional allows both Tower and Rack mount e Rotating front panel LCD display gives direct access to UPS Settings adjusting output voltage e Simple programming from the front panel LCD screen enables the frequency to be set to 50 or 60 Hz LCD Rack Display E6 LCD RT Evolution 1000 VA Programmable outlets allow users to easily control different loac LCD display and or Infopower software Warm swappable batteries The E6 LCD RT EVOLUTION equipped with a practical and versatile battery system gives the user the opportunity to replace batt without stopping the UPS and consequently without interrupting the power supply to critical and vital loads COMMUNICATION Communication software e nfoPower control software supplied as standard e f there is no power the UPS close the files automatically and in doing so save data from all the PCs in a network e The communication software offers a graphic interface to view system status various measurements events log ete Overload protection e Protection of internal power components e prevention of connection errors e reliability automatic control of loads power supply and UPS i
Download Pdf Manuals
Related Search
Related Contents
White Rodgers 1F80-0471 Thermostat User Manual Manuel d`utilisation Sanyo PLC-SW20A AudioTrak MAYA44 MKII Sound Card HP 8100 Series User's Manual EN-6704V,6708V - English User Manual Copyright © All rights reserved.
Failed to retrieve file