1. To add a module to the configuration 1 Select desired module in Available Modules list The Input Output and Params data sizes are based on the modules within the Selected Modules window 2 Click Right Arrow Button or double click a previously selected module The selected module is added to the Selected Modules list if there are sufficient resources available on the adapter 4 I O and Parameters Resources are updated every time the Selected Modules window is changed el Note The maximum number of EIP 200S modules is 63 The maximum number of EIP 200Pro modules is 17 including the virtual slot Input and Output data size to 255 and total parameter size to 237 including adapter parameters If you exceed any of these limits a message box is shown stating which limit has been reached The current resource usage is updated upon any modification to the overall configuration 5 Click OK The current list of selected modules is updated into the adapter configuration of the Network View 32 Adapter Configuration 2014 Molex Incorporated Document Edition 1 1 2 0 Document 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide To remove a module 1 Select desired module in Selected Modules list 2 Click Left Arrow Bu
2. viii Preface 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Overview Chapter Sections e Introduction e Installing the Tool e Creating a New Configuration e Saving a Configuration e Opening a Configuration e Printing a Configuration Overview 9 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 1 1 Introduction This manual describes the use of the EIP ET200 Configuration Tool The tool is used to configure ET200 adapter modules in both offline no connection to the EtherNet IP network and online connection to the EtherNet IP network via an Ethernet Network Interface Card modes It can also be used in monitoring diagnostics on an ET200 adapter The tool has two modes of operation offline and online Offline Mode When you do not have an immediate access to ET200 adapter module configurations generated with the tool can be saved and later used in Online Mode to configure the
3. Note The firmware updating uses an external application TFTP Trivial File Transfer Protocol Microsoft Windows provides such utility but it might be not installed by default In case you see the message below please install the TFTP utility on your system x Cannot find TFTP utility please make sure it is installed on your system Note The TFTP Client feature is installed by default on Windows XP On Windows 7 and Windows 8 1 the TFTP Client feature has to be turned on manually It resides in Control Panel gt Programs gt Programs and Features gt Turn Windows features on Or off 26 Setting Online Connection Properties 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 2 4 Uploading a Configuration Once the connection settings are established start configuring the ET200 adapter device If the adapter device has been configured before or you are not sure of its current configuration state it is recommend that you try to upload the configuration information currently stored in the device before continuing To start the upload choose the Adapter Upload Configuration command or click the Upload Configuration button t f To open the Adapter Modu
4. QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 5 Click OK The new entry appears in the Configured Drivers list Configure Drivers Available Driver Types EtherNet IP Driver Configured Drivers Name and Description Status AB_ETHIP 1 A B Ethernet RUNNING Running 6 Close the Configure Drivers window The ET200 adapter is detected and displayed in the device list X RSLinx Classic Professional RSWho 5 File Edit Yiew Communications Station DDE OPC Security Window Help S 818 Bile X Browsing node 192 168 1 250 found Device Type ge Linx Gateways Ethernet j 192 168 1 250 EIP 2005 Adapter EIP 2005 Adapter OK ge AB_ETHIP 1 Ethernet 192 168 1 250 EIP 2005 Adapter EIP 2005 Adapter For Help press F1 SCRL 05 03 12 12 03F Configuring ET200 in RSLogix5000 and RSLinx 49 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 4 5 Setting up the ET200 Module s IP Address The ET200 adapter comes from the factory without an IP address assigned and it must
5. or select the menu File Print command The Print dialog box appears Microsoft XPS Document Writer Properties Ready Microsoft XPS Document Writer XPSPort 2 Select the desired printer name and print range and click OK Note Select the menu File Print View command to set the desired settings for the printed page Select the menu File Print Setup command to set the desired printer paper size and orientation Overview 15 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 16 Overview 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Setting Online Connection Properties Chapter Sections e Introduction e Ethernet Network Interface Card Connection Configuration e ET200 Configuration Objects e Uploading a Configuration e Downloading a Configuration Setting Online Connection Properties 17 2014 Molex Incorporated Document Edition 1 1 2 0 D
6. and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool E Module Properties EIP 1 1 General Connection Module Info Internet Protocol Port Configuration Type EIP 2005 Adapter Vendor Molex Incorporated Parent EIP Name Ethernet Address Private Network 192 1681 31 Description O IP Address Host Name Module Definition Revision 1 1 Electronic Keying Compatible Module Connections Listen Only Status Offline 6 Select desired connection type between Exclusive Owner Input Only and Listen Only connection 7 Configure I O sizes according to the downloaded ET200 configuration el Note The Input Size and Output Size are displayed in the Module Configuration Parameters in the EIP ET200 Configuration Tool 44 Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool Use
7. Any user configuration and IP address will be lost without checking Retain IP Address Auto Configuration I O Status Byte Enabled will be set and DHCP mode will be enabled To reset the adapter click the Reset button it will restart the adapter and place it in its initial state hi Note User configuration data is not lost after this type of reset Setting Online Connection Properties 21 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool i Connection Device IP 192 168 1 8 Network IP 192 168 1 88 k Browse Identity TCP IP Ethemet Firmware Identity Parameters Vendor ID 8 Factory Defaults Device Type 12 Set Defaults Product Code 570 Retain IP Address Revision 2 1 Status No I O Connection Serial Number 131036913 Product Name EIP200PRO Adapter 2 3 2 TCP IP Object Parameters The TCP IP tab allows you to view set various adapter TCP IP parameters of the adapter To retrieve current the TCP IP parameters click the Read button A request is sent to the adapter and the display is updated with the current values To set the TCP IP parameters make the changes you wish to incorporate click the Write
8. ET200 adapter in RSLogix5000 Before connecting with the ET200 adapter The EIP200S eds or EIP200Pro eds file needs to be registered using Allen Bradley EDS Hardware Installation Tool The EIP200S eds and EIP200Pro eds files are part of the EIP ET200 Configuration Tool installation They can be found in where the EIP Configuration Tool is installed To use registered ET200 adapter in RSLogix5000 1 Right click the 1756 ENBT module and select the New Module command 2 To easily locate ET200 Adapter select only the Molex Incorporated check box 3 Select the EIP200S or EIP200Pro Adapter and click the Create button SS Catalog Module Discovery Favorites Enter Search Text for Module Type Module Type Category Filters Si Module Type Vendor Filters Communication Mettler Toledo Communications Adapter Molex Incorporated Controller Parker Hannifin Corporation Digital Prosoft Technology m v Catalog Number Category 0008_000C_0239 EIP 200S Adapter Molex Incorporat Communications Adapter EIP 200PRO Adapter Molex Incorporat Communications Adapter 2 of 211 Module Types Found Add to Favorites Close on Create 4 Specify the Name and IP Address in Module Properties 5 Click on the Change button to setup connection type and I O sizes Configuring ET200 in RSLogix5000
9. Oe ce et a eh e a E ule Bi as a 22 2 3 3 Ethernet Link Object Parameters sccatsa sacdecascecodajaeasceds sac torece seein REM Re 23 Contents iii 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 34 Fitmware Upd tesc ae stats ns iti eiee e oe as a ised e E AA R 24 2 4 Uplo ding a Config ralo Ma n slats Pec aay in a a E E ESS 27 2 5 Downloading a Configuration sf cee Ait hace ii GG Se Aah ae eae 27 Ad pter Configuratio N sisici sieisen aeiiae baene e ekaan noi ira beieco konia re hainin 29 SLOVENI EW eea a tas a a a aa Gre a a N N 30 3 2 Automatic Configuration vs User Configuration Mode seseseseseeeesseseresresseseresresseseresresse 30 3 3 Enabline TO Stags eiie tni a et r a EEES Ts 31 3 4 Adding Removing and Re ordering a Module ssesseeeseseesseseeesesrsesresseseresressesersseesseserssresse 31 3 5 Viewing and Changing Module Properties essessessesessseeeeeserssesrerseeseserssresstsersseesseseresresee 34 3 5 1 Module Configuration Parameters s eesseseeeseesesseeseeressetsrestessesseeseesseeseesereseeseseresreses 34 3 5 2 Extended Parameters Group seeesesesesesressteeresressessresressessrestessetsteseesseessesrresteseesereseeset 35 3 6
10. T O System Manual A5E03822408 and Siemens SIMATIC ET 200pro distributed I O system Operating Instructions A5E00335544 08 Adapter Configuration 39 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 40 Adapter Configuration 2014 Molex Incorporated Document Edition 1 1 2 0 Document 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Configuring ET200 in RSLogix5000 and RSLinx Chapter Sections e Introduction e Setting up ControlLogix e Configuring ET200 adapter in RSLogix5000 e Setting up RSLinx e Setting up ET200 module s IP address Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document 41 User Reference Guide EIP ET200 Configuration Tool 4 1 Introduct
11. button A request is sent to the adapter and the parameters are updated with the displayed values IP Address Current IP address of the adapter Network Mask Gateway Address Host Name eip200s or eip200p last 3 bytes of the ET200 MAC address Boot Options Quick Connect 22 Setting Online Connection Properties 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide m Connection Device IP 192 168 244 136 Network IP 192 168 244 133 v Browse Identity TCP IP Ethernet Firmware TCP IP Paramters IP Address pHi 192 168 244 136 Static Address Network Mask BOOTP aaa DHCP Gateway Address I Quick Connect 2 3 3 Ethernet Link Object Parameters The Ethernet tab allows you to view various adapter Ethernet Link object parameters and also allows setting interface speed and duplex mode of the adapter Two Ethernet Link objects exist on the adapter select desired Port number 1 or 2 To retrieve the current Ethernet Link object parameters select the port number and then click the Read button A request is sent to the adapter and display is updated with the current values To set the Ethernet Link ob
12. disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Preface Preface Sections e Purpose of this Guide e Conventions Preface V 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool Purpose of this Guide This manual describes the use of the EIP ET200 Configuration Tool The tool is used to configure ET200 adapter modules in both offline no connection to the EtherNet IP network and online connection to the EtherNet IP network via an Ethernet Network Interface Card modes It can also be used in monitoring diagnostics on an ET200 adapter K Note For adapter technical details of ET200 modules refer to the appropriate Siemens SIMATIC EIP 200S EtherNet IP Adapter Distributed I O System Manual A5E03822408 and Siemens SIMATIC ET 200pro distributed I O system Operating Instructions A5E00335544 08 Conventions This guide uses stylistic conventions special terms and special notation to help enhance your understanding Style The following stylistic conventions are used throughout this guide Bold button names tab name
13. enabled for a device upload the configuration The I O Status Adapter Configuration option indicates current state of the I O Status feature To enable disable the I O Status feature double click the I O Status parameter in Adapter Configuration group of parameters or select a desired option from dropdown selection in Properties windows The I O Status feature is enabled by default el Note I O Status is enabled in auto configuration mode When the I O Status feature is enabled the tool will automatically increment the number of Input bytes by one 1 to reflect the change in the input data packet size 3 4 Adding Removing and Re ordering a Module To view the current modules configuration click the Adapter Select Modules menu command or right click in the Network View window and click Select Modules command The Select Modules dialog box is displayed where you can modify your modules configuration Adapter Configuration 31 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool Selected Modules Slot Module Name 1 Virtual Slot for PS Resources Modules lof 17 Input 1 of 255 Output Oof 255 Params 18 of 237 Remove All 1 Output O Params
14. 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 2 3 ET200 Configuration Objects The Connection Properties allow accessing changing various properties of the ET200 adapter device You can monitor set the following device objects e Identity Object Parameters e TCP IP Object Parameters e Ethernet Link Object Parameters 2 3 1 Identity Object Parameters The Identity tab allows you to view various adapter identity parameters and also allows setting factory defaults and or resetting the adapter To retrieve current Identity parameters click Read button a request is sent to the adapter and parameters are updated with their current values Vendor ID 8 Molex Incorporated Device Type 12 Communication Device Product Code 569 570 Unique Device Identifier 569 ET200S 570 ET200PRO Revision 1 1 Firmware revision number Status Current status of the adapter Serial Number Device unique serial number Product Name EIP200S Adapter or EIP200PRO Adapter To set the ET200 Adapter to its factory default settings click the Set Defaults button To keep the current IP address check the Retain IP Address before clicking the Set Default button The Retain IP Address feature is only supported by the ET200PRO module Note
15. Industry Inc 1 Internet Plaza Johnson City TN 37604 423 262 5710 Phone 423 262 2289 Fax 800 333 7421 Hotline E mail support automation siemens com 54 Technical Support 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document
16. Viewing and Changing Adapter Properties eeseseessesereseeseeseessesrersrtseseresresesereseesseseresesee 36 3 6 1 Adapter Configuration Parameters 2 cc43h 5 neg ie Bae oe Beads Beene 36 3 6 2 Extended Parameters Group se csi202 usd ecedsiesldeesiiaiicek ides ees OR ee eed 37 3 7 Using Online Dia CNOSt Cs aris eet rea cet ee a teeta a Cie alent ie et ata 38 Configuring ET200 in RSLogix5000 and RSLINX o oo eeteceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 41 All IintroduetrOn s ss22 0226 chert eteca nde feteti cepts tie chan ee seansne sede a aaw eda ses eet aes dees anti edastanaaee 42 42 Sette up Control worn M c 3 seer 5 3 n oats fxs a i Boece ated es etaee TI E EE es 42 4 3 Configuring ET200 adapter in RSLogix5000 15 cocci aaa tianisa dan amaesaan eters 43 4 4 Setting up RSLINK M etnei np eien aaa e E ae EE K EEEo sees aundavcnateabn bese E a Ei 46 4 4 1 Configuring an EtherNet IP Driver in RSLINX ss ssssssesseessssrsssressersseesseresseeessressresse 48 4 5 Setting up the ET200 Module s IP Address s snonsseseseeeesseessessessseessseessstessersserssesesseesssees 50 Technical SUpport sieiiisisriaian anisina eiaa aii in eaa aaaeei diaaa ainai adiada ania 53 A VUSA Techical Support 2 2 ist a e ae a E A A Ai aes 54 PA Get Fie Mp ae le at o ae a Sg Ta ote alate a alg a 54 iv Contents 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or
17. age ii of this document User Reference Guide EIP ET200 Configuration Tool 1 3 Creating a New Configuration Creating a configuration allows you to specify the expansion module configuration for an ET200 device and enables configuration of each module s extended parameters 4eado 2 e 4 m e III Disgnostic Nome status E J Computer 6 a NIC 192 168 1 88 amp EIP ET200PRO 192 168 1 8 f 1 Virtual Slot for PS cE 2 6ES7 141 4BF00 0AA0 8DI Modes o ood 3 6ES7 142 4BD00 0AB0 4D0 DC24V f 4 4 6ES7 144 4GFO0 0AB0 4AII 5 pter mntiguratior a i J 5 6ES7 145 4GF00 0AB0 4A0 I ProductName EIP ET200PRO Alias Description Type ID 570 IP Address 192 168 1 8 Slots 5 Adapter Input 10 Adapter Output 9 Config Input 10 Config Output 9 Auto Config disable VO Status enable Parameter Params 00 00 00 OC 21 00 00 00 00 20 00 00 00 00 00 Params Size 15 Bd Parameters To create a new configuration CAP NUM SCRL e Choose the File New ET200S or File New ET200PRO command or click the New ET200S or ET200PRO button in the toolbar 12 2014 Molex Incorporated Overview Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Refe
18. arameters display general module information Module Configuration Name Alias Description Module ID Config Data Slot Number Input Size Output Size Parameters Params Group diagnosis Behavior at CPU STOP Rated operating curr x10 mA Response to asymmetry Beh supp volt swit elem miss Response to residual curr det Params Parameter of the module shown in hexadecimal format 3RK1 304 5LS40 5AA3 RSe ST 1BO EO 14 00 96 00 00 00 00 48 00 00 00 00 disable Switch substitute value 0 150 Turn off Group error Turn off 34 Adapter Configuration 2014 Molex Incorporated Document Edition 1 1 2 0 Document 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Module Name shows the individual module part number and name It is a read only parameter Alias is a name given by user to uniquely identify a module This parameter is settable and optional The length of the string is limited to 80 characters Description is a user short description of the module This parameter is settable and optional The length of the string is limited to 80 characters Module ID is a unique identifier of the module It is a read only parameter Config Data is a configuration data of the module It is a read on
19. ate Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide m Connection Device IP 192 168 244 136 Network IP 192 168 244 133 Browse Identity TCP IP Ethemet Firmware Revision 2 1 Firmware R02 01 00_00 01 09 00 To update the firmware in the adapter follow these steps e click the Download Firmware button e browse the firmware file UPA extension and select it A message appears displaying version of the firmware file and on the adapter and asks the user to confirm the firmware update request Do you want to update firmware file from version R02 01 00_00 01 07 00 to R02 01 00_00 01 09 00 No Downloading the firmware takes several seconds the adapter resets itself the new firmware initializes and the adapter is ready for communication Setting Online Connection Properties 25 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool Cl Note User configuration remains valid after firmware download
20. be set with a DHCP server This procedure describes how to set the IP address with the Allen Bradley BOOTP DHCP Server and how to make the IP address static permanent The module would then keep the IP address through a power cycle and a DCHP server would no longer be needed The AB BOOTP DHCP Server can be downloaded free from the Internet 1 Open the BOOTP DHCP Server the BOOTP DHCP Server dialog box appears Cs BOOTP DHCP Server 2 3 z x File Tools Help Request History Clear History hr min sec Type Ethernet Address MAC IP Address Hostname 16 17 46 DHCP 00 1B 1B 69 F1 4E 16 17 40 DHCP 00 1B 1B 69 F1 4E 16 17 36 DHCP 00 1B 1B 69 F1 4E 16 16 34 DHCP BC AE C5 75 B4 64 Relation List New Ethernet Address MAC IP Address Hostname Description Status Entries Unable to service DHCP request from 00 1B 1B 69 F1 AE 0 of 256 2 When the MAC address for the EIP200 module shows up in the AB BOOTP DHCP Server Request History window double click the entry or select the entry and then select the Add to Relation List button 3 Inthe pop up dialog enter the IP address and select OK When the IP address is assigned a new entry will appear with an address in the IP Address column The Net Status LED on the module should change to blinking green which indicates an IP address is assigned 50 Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Docu
21. ce being configured The parameters specify data to be written to the adapter to configure its behavior You can only change the values of entries in the text parameters by double clicking the desired field or selecting the dropdown field or clicking a spin control up or down arrow depending on parameter predefined range of values Any changes to the parameters are reflected in its hexadecimal format Adapter Configuration 37 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 3 7 Using Online Diagnostics The EIP ET200 configuration tool can be used online to monitor the state of the adapter module and provide diagnostic information on configured slots You can make sure all slots are functioning normally or if there are errors monitor each slot s error state To use online diagnostics 1 Click the Monitor button 2 Select the adapter or a slot in Network View to display respective diagnostic information pos Pe Be RR ee a File Adapter View Help JAG 8 2 o 4 tm o CIES Diagnostic Name Status Type Module Status Slot 1 Module Warning Channel 0 Sensor or load voltage missing 17 N A E J Compute
22. device Online Mode Online configuration mode is possible when you have a An Ethernet Network Interface Card in your system b ET200 adapter device The tool is able to communicate with the module s over an EtherNet IP network directly through an Ethernet Network Interface Card to upload or download configuration data In Online Mode the tool can also display diagnostic information from the ET200 Adapter 10 Overview 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 1 2 Installing the Tool The EIP ET200 Configuration Tool supports 32 Bit Windows XP Windows 7 Windows 8 1 and 64 Bit Windows 7 Windows 8 1 To install the EIP ET200 Configuration tool run the setup program ET200Setup exe and follow the instructions on the screen The install program will guide you through the setup process lal Note Custom Setup Type can be chosen to install the EIP ET200 Configuration Tool in a different directory Overview 11 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on p
23. ea a E a a E S a aE S rE S E E N V Purpose of this Gude eoeta a a E a Eee SE vi CONVENTIONS 54 5 555 025501 os enen a ESEA AS E EESE EK EA SAE E stead ee eee SE Eaa vi PLS ch ste cca EEE EE E EE A EA E A vi Special Notat Neee E R a a N vii EA ETETE T T E A T 9 TT TOU C LEONE AREATA TE E T A E E A T TE 10 1 2 Installing the Toolsin en aa a E a E Sa 11 1 3 Creating a New Configuration ss 4is scasssecsaadsstiveciansacaatas sotecnssnccauasbevensaavecactessdetensteesaanesaviness 12 It Saying a On Surat OM go G5 eect cs espana echoed case wan E e E a e E E a aait 13 lS Openinga ON EL UN AL TON gaz gusge daa e Sale de avn gy tee ea lech gad hae warn ce oun eens 14 1 6 Printing a Configuration 51 50 59 ec0c5 sacsaasndeydadeysededeseabdeaads iaa E K a a E 15 Setting Online Connection Properties cccccceeessseeseeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeneees 17 2 Al OCU CMON ae essed at aA eislean aaah totic Balad st wo nuatia tal e Esi e tutus E oE 18 2 2 Ethernet Network Interface Card Connection Configuration cesccecseseeeseeceeeeeeeeneeees 18 2 2 1 To Set the Connection Properties coscsssccch bina cdavatsncochdisoceaateasdestevesasadogiaaeeceaseaasaee 18 222 Fire walland Enable Broadcast q diantache causes ay aia ak cota es ean ethene 20 2 3 ET200 Configuration ODjeCts cssc oisinnean ESE EAEE EEE TE 21 2 31 Identity Object PARAM CLEIS wsi2 4oc09 ssa5eudetsedages aisea e i a iE eE eses 21 2 32 GPU ODI SOU Patra Meters Pein Sigua BUG
24. efault parameters User Configuration mode allows you to specify the module in each slot and configure each module s extended parameters if supported In User Configuration mode extended diagnostic support is available for modules that support it Auto Configuration User Configuration NO Add Remove modules without updating configuration details Hot swap works in both mode Download configuration information Extended diagnostics YES NO User selectable I O data compression YES always compressed To enable disable Auto Configuration Mode double click the Auto Config parameter in Adapter Configuration group of parameters or select a desired option from dropdown selection in Properties windows Auto Configuration Mode is enabled by default 30 Adapter Configuration 2014 Molex Incorporated Document Edition 1 1 2 0 Document 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 3 3 Enabling I O Status The I O Status Enable feature generates a single I O status byte at the beginning of the input data packet This status byte indicates if any faults have occurred in the device which may result in invalid data i e short circuit blown fuse To determine whether I O status is
25. iguration To open a configuration the following graphic is based on Windows 7 1 Click the Open button lay box appears or select the File Open menu command The Open dialog Open gO gt Libraries Documents gt x gt Organize v New folder 4 yr Favorites Documents library MB Desktop Includes 2 locations l Downloads Name Date modified Type Arrange by Folder v 1 Recent Places db Downloaded Installations 06 11 2013 11 58 File folder fal My Music 3 10 2012 2 54 PM File folder amp My Music 14 07 2009 12 53 File folder fa My Pictures 03 10 2012 2 54 PM File folder amp My Pictures 14 07 2009 12 53 File folder ali My Videos 3 10 2012 2 54 PM_ File folder amp My Videos 14 07 2009 12 53 File folder wv ina v Eip200Cfg Files etc z Cancel a 3 Libraries gt Documents gt d Music gt e Pictures amp Videos 4 Comnuter 2 Select the desired ETC configuration file and click Open 14 Overview 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 1 6 Printing a Configuration To print a configuration 1 Click the Print button a
26. igure Drivers option from the Communications menu The Configure Drivers dialog box appears Configure Drivers Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document 47 User Reference Guide EIP ET200 Configuration Tool 4 4 1 Configuring an EtherNet IP Driver in RSLinx 1 From the Available Driver Types dropdown box choose EtherNet IP Driver 2 Click the Add New button and specify the name of the new driver for example AB_ETHIP 1 Add New RSLinx Classic Driver Choose a name for the new driver 15 characters maximum AB_ETHIP 1 3 Click OK The Configure driver AB_ETHIP 1 dialog box appears 4 Select the NIC card you want to communicate through Configure driver AB_ETHIP 1 EtherNet IP Settings Browse Local Subnet Browse Remote Subnet Description IP Address Windows Default 3Com 3C905T based Ethernet Adapter Generic 3 Teefer2 Miniport 192 168 1 2 Marvell Yukon 88E8053 PCI E Gigabit Ethernet Controller Teefer2 Mi 10 26 15 51 Cancel Apply Help 48 Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template
27. ion This chapter describes the steps for configuring ET200 adapter using RSLogix5000 version 20 0 or higher with 1756 ENBT EtherNet IP scanner The following sections describe how to set up the system with a ControlLogix system using ET200 EDS file Note Detailed instructions on setting up a ControlLogix Rack and using the RSLogix5000 tool are not within the scope of this document This document assumes you have a working knowledge of RSLogix5000 the ControlLogix system and the 1756 ENBT EtherNet IP module for the ControlLogix system 4 2 Setting up ControlLogix Equipment e Allen Bradley ControlLogix PLC configured with a ControlLogix CPU module e Allen Bradley EtherNet Bridge Module ENBT Setup 1 Connect the 1756 ENBT module to an available computer Ethernet port via an Ethernet cable 2 Connect the ET200 adapter to EtherNet IP network 3 Power up the PLC if necessary configure the PLC using the appropriate software applications as documented in the user s manual provided with the PLC 42 Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 4 3 Configuring
28. ject parameters select the port number and then click the Write button A request is sent to the adapter and the parameters are updated with displayed values Speed MAC Address Interface Label Interface Flags Duplex Mode Setting Online Connection Properties 23 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool r Connection Device IP 192 168 244 136 Network IP 192 168 244 133 v Browse Identity TCP IP Ethemet Firmware Ethernet Parameters Port hd Speed Auto v Mbps MAC Address 00 1B 1B 69 F5 D5 Interface Label Port 1 m Interface Flags Link Status Half Full Duplex Settings Local Hardware Fault Negotiation Status F Duplex Mode 2 3 4 Firmware Update The Firmware tab allows you to view the current firmware revision in the adapter and also allows downloading and updating the firmware in the adapter To retrieve the current firmware revision click the Read button A request is sent to the adapter and the current firmware revision is displayed 24 2014 Molex Incorporated Setting Online Connection Properties Document Edition 1 1 2 0 Document Cl 6214 Templ
29. le Configuration dialog box choose the Adapter Select Modules command or click the Edit Adapter Configuration Parameters button e in the toolbar For detailed information about adapter configuration please refer to chapter 3 Adapter Configuration 2 5 Downloading a Configuration Once all settings in the configuration are completed as described in Chapter 3 Adapter Configuration download the configuration to the adapter module To download 1 Choose the Adapter Download Configuration command or click the Download Configuration button 2 The progress bar displays current status of the downloading command and notifies you once completed Setting Online Connection Properties 27 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 28 Setting Online Connection Properties 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Adapter Configuration Chapter Sections e Overview e Automa
30. ly parameter Slot Number is the position of the module in reference to adapter slot It is a read only parameter Input Size is the byte length of the Input data It is a read only parameter Output Size is the byte length of the Output data It is a read only parameter lal Note In AutoConfig mode editing parameters is disabled 3 5 2 Extended Parameters Group Parameter Group displays hexadecimal representation of the parameters and where available a text representation of modifiable module parameters Text and Hex parameters are specific to the expansion module being configured The parameters specify data to be written to the expansion module to configure its behavior You can change the values of entries in the text parameters by double clicking the desired field or selecting the dropdown field or clicking a spin control up or down arrow depending on parameter predefined range of values or manually enter the values within the range Any changes to the parameters are reflected in its hexadecimal format Adapter Configuration 35 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 3 6 Viewing and Changing Adapter Properties The Adapter Properties contai
31. ment Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide r New Entry Ethernet Address MAC 00 1B 1B 69 F1 AE IP Address 192 168 1 8 Hostname Description 4 To make the IP address permanent select the entry in the Relation List window and select the Disable BOOTP DHCP button If successful the Status window at the bottom will display Disable DHCP Command successful Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document 51 User Reference Guide EIP ET200 Configuration Tool 52 Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Technical Support Appendi
32. molex one company gt a world of innovation EIP ET200 Configuration Tool User Reference Guide Document Edition 1 1 2 0 Document Cl 6214 User Reference Guide EIP ET200 Configuration Tool Document Edition 1 1 2 0 Date May 7 2014 This document applies to the EIP ET200 Configuration Tool Copyright 2014 Molex Incorporated This document and its contents are the proprietary and confidential property of Molex Inc and or its related companies and may not be used or disclosed to others without the express prior written consent of Molex Inc and or its related companies SST is a trademark of Molex Inc All other trademarks belong to their respective companies At Molex we strive to ensure accuracy in our documentation However due to rapidly evolving products software or hardware changes occasionally may not be reflected in our documents If you notice any inaccuracies please contact us see Appendix A of this document Written and designed at Molex Incorporated 216 Bathurst Drive Waterloo Ontario N2V 2L7 Canada Hardcopies are not controlled 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Contents CC ee iii Preface nonan
33. ns configuration options that affect the Adapter s global behavior To view an adapter s properties select the adapter EIP200S device in the Network View The Adapter Parameters are shown in the Properties Window The Property Window consists of 2 groups of parameters Adapter Configuration parameters and Extended Parameters 3 6 1 Adapter Configuration Parameters The Adapter Configuration Parameters display general adapter information Ej Product Name EIP ET200PRO Alias Description Type ID 570 IP Address 192 168 1 8 Slots 5 Adapter Input 10 Adapter Output 9 Config Input 10 Config Output 9 Auto Config disable VO Status enable j 00 00 00 OC 21 00 00 00 00 20 00 00 00 00 00 Params Size 15 Operation for ref lt gt actual conf disable Identifier related diagnostics enable Submodule status enable Channel related diagnostics enable Option handling disable Params Parameter of the adapter shown in hexadecimal format 36 Adapter Configuration 2014 Molex Incorporated Document Edition 1 1 2 0 Document 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide Product Name is the name of the adapter device It is a read only parameter Alias is a name given by user to uniquely identify an adapter This parameter i
34. ocument Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 2 1 Introduction This chapter describes the necessary steps to select an Ethernet network interface card for use as the communication channel to allow an ET200 adapter module to be configured online 2 2 Ethernet Network Interface Card Connection Configuration The Connection Setup defines the network configuration settings to use when communicating with the Adapter Module in Online Mode The ET200 module in factory default is only with DHCP enabled and no IP address It will not work until the IP address is set with a DHCP server Please refer to section 4 5 Setting up the ET200 Module s IP Address 2 2 1 To Set the Connection Properties 1 Choose the Adapter Connection Setup command or click the Connection button amp The EtherNet IP Connection dialog box appears 18 Setting Online Connection Properties 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide EtherNet IP Connection X Connec
35. orporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 2 2 2 Firewall and Enable Broadcast By default most programs are blocked by Windows Firewall When Windows Firewall is active if you use the Broadcast request to search for existing ET200 adapters the EIP ET200 configuration tool needs to be added to the firewall exception list 2 2 2 1 To Enable Broadcast on Windows XP 1 From Windows Start click Settings gt Control Panel gt Security Center 2 Inthe Windows Security Center under Manage security settings for select Windows Firewall 3 Inthe Windows Firewall dialog box on the Exceptions tab click Add Program 4 Click Browse and then locate the EIP ET200 Configuration Tool Click OK 2 2 2 2 To Enable Broadcast on Windows 7 and Windows 8 1 1 From Windows Start click Control Panel gt System and Security 2 Under Windows Firewall click Allow a program through Windows Firewall 3 Inthe Allow programs to communicate through Windows Firewall dialog box click Change settings 4 Click Allow another program then locate the EIP ET200 Configuration Tool Click Add 20 Setting Online Connection Properties 2014 Molex Incorporated Document Edition 1 1 2
36. r Channel 1 No error 0 N A NIC 192 168 1 88 Channel 2 No error 0 N A EIP ET200PRO 192 168 1 25 Channel 3 No error 0 N A i 1 Virtual Slot for PS Channel 4 No error 0 N A 2 6ES7 141 4BH00 0AA0 16DI Channel 5 No error 0 N A 3 6ES7 142 4BD00 0AB0 4D0 DC24V HF Channel 5 we mo va i 4 6ES7 142 4BD00 0AA0 4D0 DC24V Modules 44 Module Cor L a Name Virtual Slot for PS Alias Description Module ID Virtual Config Data 00 00 00 Slot Number 1 Input Size 0 Output Size 0 S Para gt Params 20 01 00 x l ee Ready CAP NUM SCRL 38 Adapter Configuration Document Edition 1 1 2 0 Document 6214 Template Edition 1 1 Template QMS 06 045 2014 Molex Incorporated Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 3 To turn the diagnostic function off click the Monitor button again Cl Note When going into diagnostic mode the current configuration is compared with the configuration stored in the adapter in case a mismatch is found there is an option to overwrite current configuration or not to go into diagnostic mode Note Online diagnostics are not available in Auto Configuration mode For more information on the diagnostics of ET200 modules refer to the appropriate Siemens SIMATIC EIP 200S EtherNet IP Adapter Distributed
37. r Reference Guide E Module Definition Revision Electronic Keying Compatible Module Connections Name Exclusive Owner Exclusive Owner Input Only Listen Only 8 Click OK button to confirm your settings 9 Download the configuration to the PLC and place it online Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document 45 User Reference Guide EIP ET200 Configuration Tool 4 4 Setting up RSLinx 1 Install Rockwell Automation RSLinx software on the system according to the instructions provided 2 Open RSLinx via the RSLinx menu shortcut The main screen is displayed Linx Gateways Ethernet 3 To browse the network click on the RSWho button or menu item from the Communications menu 46 Configuring ET200 in RSLogix5000 and RSLinx 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide 4 To configure RSLinx select the Conf
38. rence Guide 1 4 Saving a Configuration To save a configuration the following graphic is based on Windows 7 1 Click the Save button ER or choose the File Save or File Save As menu command If the configuration was not previously saved the Save As dialog box displays Save As G gt Libraries Documents gt Organize v New folder aF Favorites Documents library i Arrange by Folder v W Desktop Includes 2 locations pi Downloads Name Date modified Type E Recent Places di Downloaded Installations 06 11 2013 11 58 File folder a My Music 3 10 2012 2 54PM File folder 4 07 2009 12 53 File folder 4 5 Libraries gt Documents a My Music gl Music fa My Pictures 10 2012 2 54 PM File folder E Pictures amp My Pictures 4 07 2009 12 53 File folder ke ali My Videos 3 10 2012 2 54PM_ File folder amp Videos File name Save as type Eip200Cfg Files etc a Hide Folders 2 Enter a file name and click Save w Note Configuration files are saved with the etc file extension Overview 13 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 1 5 Opening a Conf
39. s and options or selections Italics indicates keywords indexed or instances of new terms and or specialized words that need emphasis CAPS indicates a specific key selection such as ENTER TAB CTRL ALT DELETE Code Font indicates command line entries or text that you would type into a field Underlining indicates a hyperlink vi Preface 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document EIP ET200 Configuration Tool User Reference Guide gt delimiter indicates how to navigate through a hierarchy of menu selections options Ox indicates a hexadecimal value NIC indicates a network interface Card Special Notation The following special notation is used throughout this guide al Note A note provides additional information emphasizes a point or gives a tip for easier operation Notes are accompanied by the symbol shown and follow the text to which they refer Preface vii 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool
40. s settable and optional The length of the string is limited to 80 characters Description is a user short description of the adapter This parameter is settable and optional The length of the string is limited to 80 characters Type ID is a unique identifier of the adapter It is a read only parameter IP Address is a unique IP address on the network It is a read only parameter but it can be changed through the connection setup Slots is the number of currently configured modules It is a read only parameter Adapter Input is the byte length of the Input data for all configured modules read from the adapter It is a read only parameter Adapter Output is the byte length of the Output data for all configured modules read from the adapter It is a read only parameter Input is the byte length of the Input data for all configured modules It also includes I O Status byte if itis enabled It is a read only parameter Output is the byte length of the Output data for all configured modules It is a read only parameter Auto Config refers to Section 3 2 Automatic Configuration vs User Configuration Mode for more information TO Status refers to Section 3 3 Enabling I O Status for more information 3 6 2 Extended Parameters Group Parameter Group displays hexadecimal representation of the parameters and where are available a text representation of modifiable module parameters Text and hex parameters are specific to the adapter devi
41. tic Configuration vs User Configuration Mode e Enabling I O Status e Adding Removing and Re Ordering a Module e Viewing and Changing Module Properties e Viewing and Changing Adapter Properties e Using Online Diagnostics Adapter Configuration 29 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 3 1 Overview The ET200 adapter configuration consists of 2 stages e Selecting modules e Configuring adapter and modules parameters The Select Modules dialog box provides a list of the currently selected expansion modules to be downloaded to the ET200 adapter You can add remove rearrange modules slots and monitor available I O and parameters resources while configuring the adapter The Property Window within the main application window allows you to view and modify adapter configuration options to modify extended parameters of the adapter and parameters of the modules within the configuration itself 3 2 Automatic Configuration vs User Configuration Mode In Automatic Configuration mode the adapter module knows only the total input and output sizes and has no extended diagnostic capabilities electronic module parameter data cannot be specified the modules use d
42. tion Device IP 192 168 244 136 Network IP 192 168 244 133 v Browse Identity TCPAP Ethernet Firmware Available Adapters Browse IP Addresses __ Browse Broadcast 192 168 244 135 Select Sub Network Unicast f Network Card Name Realtek RTL8139 810x Family Fast Description Office IP Address 192 168 244 133 2 Select the Network IP address of the Network Interface Card that you want to communicate with the ET200 adapter Click Browse button to search for existing ET200 adapters on the network A list of the available adapters is populated specifying each adapter s IP address You can browse for the adapters either using a broadcast sub network or unicast message A Broadcast request message will be sent to all networks attached to the network interface card If the Windows firewall is active refer to section 2 2 2 Firewall and Enable Broadcast A Sub Network request message will be sent to a sub network devices that belong to a subnet addressed with 3 common identical most significant bit groups Subnet mask is 255 255 255 0 A Unicast request message will be sent only to a single adapter IP address specified by Device IP address Select the ET200 adapter that you want to communicate with Click OK to save the settings or Cancel if you do not want to save the new settings Setting Online Connection Properties 19 2014 Molex Inc
43. tton or double click a previously selected module 3 The selected module is removed from the Selected Modules list The resources usage is updated accordingly 4 Clicking Remove All button removes all modules from configuration 5 Click OK The current list of selected modules is updated into the adapter configuration Note If you remove a module in the middle of the configuration list the other modules move up to fill the empty slot To re order an expansion module 1 Click the desired module in the Selected Modules list 2 Click the Up Down Button to move the slot position of the currently selected module higher or lower 3 Click OK The current list of selected modules is updated into the adapter configuration Adapter Configuration 33 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool 3 5 Viewing and Changing Module Properties To view a module s properties select the desired module in the Network View The Module Parameters are shown in the Properties Window The Property Window consists of 2 groups of parameters Module Configuration parameters and Extended Parameters 3 5 1 Module Configuration Parameters The Module Configuration P
44. x Sections e USA Technical Support Technical Support 53 2014 Molex Incorporated Document Edition 1 1 2 0 Document Cl 6214 Template Edition 1 1 Template QMS 06 045 Use duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document User Reference Guide EIP ET200 Configuration Tool A 1 USA Technical Support Please ensure that you have the following information readily available before calling for technical support Card type and serial number e Computer s make model and hardware configuration cards installed e Operating system type and version e Details of the problem you are experiencing application module type and version target network and circumstances that may have caused the problem A 1 1 Getting Help Support issues for Siemens ET200 Expansion Electronic Modules should be directed to the appropriate Siemens Technical Support facility in your area Or visit http support automation siemens com Also available as an app for both Android and Apple IOS platforms See here for further information http support automation siemens com W W view en 56295795 Please also utilize the following during normal business hour for obtaining Siemens technical support For pre sales support please contact amps automation siemens com For post sales technical support please contact tech support at SIEMENS