Home

MiniSmart Evaluation Guide

image

Contents

1. The result of each operation is display after a button is pressed A predetermined list of commands in a text file can be copied and pasted for each entry to provide a convenient means to enter each command Following is an example Read 20 Byes This operation reads 20 bytes from the Smart Card at a predetermined file address Write This operation prompts an input string of up to 20 characters and then writes the string to the predetermined file address Check Switch This operation asks for insertion removal of the card and provides the status Send Command This operation prompts an input command Use xx for Hex formatted command characters Example 17 is the command to check the status See User Manual for all available commands and responses Exit The application terminates with this operation 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 13 of 16 Product Evaluation Guide MiniSmart Intelligent Version RS232 DEMO Example To Power On Click send command and insert 12 To Select File 30 40 Click send command and insert 15 00 A4 00 00 02 30 40 To Verify CHV Click send command and insert 15 00 20 00 80 0Esamplepassword To Read 8 bytes Click send command and insert 15 00 B0 00 00 08 To Write 8 bytes 12345678 Click send command and insert 15 00 D6 00 00 0812345678 To Read 8 bytes Click send command and insert 15 00
2. 10 Serial Smart Card Reader Note Sometimes if installation fails or if power is removed from the reader after a successful installation a Scan for hardware changes process must be performed while the reader is disconnected from the PC Then connect the reader to the PC and with power connected click Scan for hardware changes 7 To properly install the PC SC driver the computer must be restarted before installation of Demo Software Demo Software Find the SETUP application on the CD Double click the SETUP file to Run the setup program Follow the installation wizard prompts to complete the installation The following information is divided into two sections The first section uses the Windows PC SC driver The second section is for RS232 communications without using the Windows PC SC driver PC SC Operation The IDT IMS DEMO application software is located in the Programs group in the Start menu Launch the program by double clicking the application icon The program will display the following interface selection window Before selecting PC SC make sure the PC SC driver is loaded Intelligetn MiniSmart Demo V1 0 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 7 of 16 Product Evaluation Guide MiniSmart Intelligent Version In the RS232 or PC SC selection window select the PC SC button The demo application will search for the MiniSmart reader t
3. ABCDEFGH Insert Command 00 D6 00 00 08ABCDEFGH Press Send T 0 APDU button 8 To Read 8 byte Insert Command 00 B0 00 00 08 Press Send T 0 APDU button 9 Press Disconnect button 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 10 of 16 Product Evaluation Guide MiniSmart Intelligent Version RS232 Operation The PC SC driver must unload from the Device Manager to run the demo program using the RS232 interface To unload the PC SC driver unplug the DB9 connecter from the PC disconnect the power supply In Device Manager Device manager can be reached through the Windows Control Panel click on System then select the Hardware folder click Device Manager button select the Action menu and select Scan for hardware changes Change the J2 jumper to open the circuit by resting the jumper clip on single pin Reconnect the cable and power supply The IDT IMS DEMO application software is located in the Programs group in the Start menu Launch the program by double clicking the application icon The program will display the following interface selection window Before selecting RS232 make sure the PC SC driver is unloaded Intelligetn MiniSmart Demo V1 0 After selecting RS232 the program will display the following window Serial Port Selection Select Serial Port Cancel 4 Input a n
4. BO0 00 00 08 To Write 8 bytes ABCDEFGH Click send command and insert 15 00 D6 00 00 O08ABCDEFGH To Read 8 bytes Click send command and insert 15 00 BO 00 00 08 To Power Off Click send command and insert 11 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 14 of 16 1on igent Versi Smart Intell ini Product Evaluation Guide M ilagram ic D Schemat Appendix A vec vec GND GND vee LED_CATHODE LED_CATHODE CARD_SEATED f CARD_SEAT_0 RXD RXD_I TO O0 aan 0 1ut DSR ea oe TCARD_SEATED _ CARD_SEAT O 1ut 5 TRXD RXD c2 GND a0 mo Ea TIIN TIOUT TosrR __ DSR TRIN T20UT RIQUT RIIN R20UT RIN P1 i RFU2 1CL3232CP H DSR 3 GND CARD SEAT 10 PIN MINI SMART 8 ae 5 4 En TE 2 o 1 of vec 10 PIN ZIF CARD_SEAT J5 P2 5 GND CARD SEAT NC 6 PIN MINI SMART 3 RxD O 6 PIN ZIF J1 J4 CONFIG 2 R5232 TTL RS232 TTL 1 3 TO PC 4 5 6 7 8 MOLEX 8 PIN 4 10 9 8 4 TO 4 APPLICATION 3 2 Ji ae 10 PIN wiwiw idt net com PROPERTY OF ID TECH CONFIDENTIAL MINI SMART EVA BOARD ize Document Number 80081307 200 E ate Tuesday May 17 2005 Bheet 1 of 1 2005 2006 International Technologies amp Systems Co
5. IDT CH Value through Innovation MiniSmart Card Reader Intelligent RS232 Interface Product Evaluation Guide 80061510 001 Rev C 10 06 Product Evaluation Guide MiniSmart Intelligent Version The information contained herein is provided to the user as a convenience While every effort has been made to ensure accuracy ID TECH is not responsible for damages that might occur because of errors or omissions including any loss of profit or other commercial damage Specifications described herein were current at the time of publication but are subject to change at any time without prior notice ID TECH is a registered trademark of International Technologies amp Systems Corporation MiniSmart and Value through Innovation are trademarks of International Technologies amp Systems Corporation The Intelligent MiniSmart Reader Evaluation Kit includes e Cover Letter e Evaluation Guide Intelligent Minismart Reader P N 80061510 001 e User s Manual MiniSmart Card Reader Intelligent P N 80061509 001 e A MiniSmart reader with bezel mounted to an evaluation board e Power supply 120VAC to 5VDC for evaluation board P N ACOOO5R 3 e Communication Cable Evaluation Board RS232 CAB1057 e D TECH standard CPU smart card P N 80005206 001 e CD with evaluation software and other information TABLE of CONTENTS Introduction an a 6 ocx aa Ean wich eds enna E Aaa alll ew etl Serene ie duane tients 3 DGS CHIPEION
6. consina naaa E aAa bondi EE A AAA E Aa a ema ANa CETNA Geile 3 Evaluation Board OperationS ssssssrrrssssrrrrressrrrrrrerrrrrrrrerrrrrrerrrrrrre 6 PC SC R9232 Operations seiis trsi renidi aaan aaa a a Unita aE aai 6 Demo SOoftWa Eir iesiena nariai iaiia r aa nea ea ae aiaa Taa a E aA ESEA 7 PCP SCOP era OM errei eerus eranan EnaA a TEET EE mute Alia EE a ECER RR E 7 Buttons and Other DescriptionS ssssssssrrrressrrrrrreerrrrrrrerrrrrrerrrrrrne 9 PC SC Demo EXIM plenis a A E AA O T EAE 10 RS232 Operati M e a a a a atk a a A paa a a aa Ea Ea 11 Buttons and Other DescriptionS ssssssserrrressrrrrressrrrrrerssrrrreesrrrre 13 Appendix A Schematic Diagram s ssssssrrrressrrrrressrrrrresssrrrrerssrrre 15 HOW to Contact US sai scate cierra aeua AE KEERA KA ETAT EAA KEEA 16 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 2 of 16 Product Evaluation Guide MiniSmart Intelligent Version Introduction This document describes a MiniSmart Intelligent reader connected to an evaluation board The board provides a convenient means for electrically connecting a PC or an application specific microcomputer unit Host to the MiniSmart reader The evaluation board has several functions which include serial communications with commands amp responses at RS232 or CMOS a k a TTL signal levels This document also includes PC Demo software operating instructions for the evaluat
7. hrough the PC SC interface If the program does not find the reader it outputs an error message and exits If successful the application displays PC SC DEMO main window as shown bellow Intelligetn MiniSmart Demo V1 0 PCSC File Help ID TECH CPU Card Quick Test Read 20 Bytes Write Generic CPU Card Operation Connect To Card Command Input pet mM Response Result 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 8 of 16 Product Evaluation Guide MiniSmart Intelligent Version Buttons and Other Descriptions There are two groups of buttons the ID TECH CPU Card Quick Test group and the Generic CPU Card Operation group The group at the top of the open window is for ID TECH CPU Card P N 80005206 001 only The group below is generic and can be used for demonstration of other cards Following is the operation performed by each button and response information Read 20 Bytes This operation connects to the card selects a file verifies PSC reads amp displays 20 bytes in a message window and disconnects the card Write This operation connects to the card selects a file verifies PSC provides a window for the user input string writes the input sting to the card and disconnects the card Connect to Card This operation establishes a connection to the card Send T 0 APDU This operation will send data in the Command Input text box to
8. ion reader The PC must have a Windows 2000 or Windows XP operating system Refer to the MiniSmart user manual for additional specifications and details Description Because the MiniSmart is small and has a flex cable connection the reader is mounted on a PCA for convenience The PCA provides a connection between the MiniSmart reader and a customer s application test assembly Host The evaluation PCA is not part of the MiniSmart reader and is not necessary in an OEM application The MiniSmart is mounted top side down on the evaluation PCA so that the bottom chassis openings face up The unit is normally mounted with these openings facing downward to allow dust and debris to fall through This orientation of the evaluation PCA amp reader causes the MiniSmart connector contacts to be on the bottom side of the reader throat Therefore a Smart Card must be inserted facing down Reader orientation does not effect reader operation There two serial communications interfaces on the MiniSmart evaluation board The MiniSmart reader PCA has a UART inside the microcontroller The signals from the microcontroller and therefore the reader are CMOS There is an RS232 converter on the evaluation board used for the RS232 interface The RS232 converter is used to convert the CMOS level signals to the RS232 level signals The jumpers on the board can be set for either an RS232 or a CMOS TTL interface For the CMOS interface the ju
9. m Connector 4 l TOSR el ce cso gme om nD LU OSR lifin R232 M i Tre P de Je Je A Je 80061507 mm u2 iSmart Eva Board i TTL amp RS232 JUMPERS 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 5 of 16 Product Evaluation Guide MiniSmart Intelligent Version Evaluation Board Operations The following information is for operating the MiniSmart using PC SC or RS232 communications through a PC COM port using the supplied Demo software The supplied communication cable must be connected to the evaluation board P3 connector and to a COM port on a PC The provided power supply must be connected to the communication cable at the rear of the 9 pin D connector shell and then plugged into a wall outlet when power is needed The User Manual provides reader specific information and the command amp response operations The User Manual is not needed for evaluation operations PC SC RS232 Operations The ID TECH IMS Demo program supports two different interfaces PC SC interface and direct RS232 interface The evaluation board jumpers must be set up for one or the other of these two interfaces The J2 jumper is used to select between PC SC or RS232 operation e For operating in RS232 interface mode open the J2 jumper circuits by resting the jumper clip on single pin only far left or far right pin this disables the DSR enumeration sig
10. mpers must be in the position 2 TTL locations when using the P3 connector When the Host is not a PC a Host specific adaptor cable may be required See the schematic for additional connection information 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 3 of 16 Product Evaluation Guide MiniSmart Intelligent Version The Evaluation board must be set up for RS232 operation jumpers in position 1 locations when using the provided Demo software The RS232 cable must be connected between P3 and an RS232 COM port ona PC See Photo The Demo software provides a means to operate the evaluation reader with the supplied test card The software supports RS232 or PC SC communications Evaluation PCA jumpers and the software select PC SC or RS232 communications See the PC SC RS232 Operations section for details The P3 Pin outs are given below for reference No Name MiniSmart Jumpers set Jumpers set In Out for CMOS for RS232 1 GND 2 TXD Out CMOS Level RS232 Level 3 RXD In CMOS Level RS232 Level 4 VCC In 5VDC 5VDC 5 NC 6 NC 7 GND 8 DSR In CMOS Level RS232 Level 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 4 of 16 Product Evaluation Guide MiniSmart Intelligent Version The Evaluation Board showing jumpers in RS232 Position 1 Locations RS232 hy ee i hmm
11. nal opens the circuit used for PC SC operation e Set the J2 jumper in the RS232 position same as J1 J3 and J4 for operating in the PC SC interface mode PC SC driver installation To run the demo program with the PC SC interface the PC SC driver must first be installed in the PC Driver installation is only needed one time Following are the basic steps for installing the driver 1 Connect the PC to the Internet unless the PC SC driver is already installed in the PC 2 Set the Evaluation board for PC SC put the J2 jumper in the position 1 location 3 Connect the communication cable to the evaluation board and to the PC COM Port 4 Apply 5Volt power to the reader using the supplied power adaptor 5 Go to the Windows Device Manager Device manager can be reached through the Windows Control Panel click on System then select the Hardware folder click Device Manager button In Device Manager select the Action menu and click Scan for hardware changes If scan for hardware changes doesn t appear in the Action menu then you must click on the window Windows will automatically install and load the PC SC driver 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 6 of 16 Product Evaluation Guide MiniSmart Intelligent Version 6 When installed the Smart Card Readers folder in the Device Manager will contain the item GemPlus GemPC4
12. rporation All rights reserved Page 15 of 16 Product Evaluation Guide MiniSmart Intelligent Version How to Contact Us Please contact us for any reason We are available during our normal business hours from 8AM to 5PM Pacific Time Monday through Friday 10721 Walker Street Cypress California 90630 PH 714 761 6368 FAX 714 761 8880 www idtechproducts com sales idtechproducts com 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 16 of 16
13. the reader The data should be in ASCII format and nonprintable characters should be represented by XX Here X is 0 9 or A F For example 00 D6 00 00 071D TECH is a correct APDU Send T 1 APDU Same function as Send T 0 APDU but for T 1 card only Disconnect This operation disconnects the card 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 9 of 16 Product Evaluation Guide MiniSmart Intelligent Version PC SC Demo Example The following example shows how to operate the ID TECH CPU card T 0 with buttons from the Generic CPU Card Operation group Each command can be typed into the command input box before pressing the Send T 0 APDU button Alternatively commands can be copied from a text file and then pasted into the command input box The copy amp paste process can reduce typing errors dh Press Connect to Card button 2 To Select File 30 40 Insert Command 00 A4 00 00 02 30 40 Press Send T 0 APDU button Response 3 To Verify CHV Insert Command 00 20 00 80 0Esamplepassword Press Send T 0 APDU button 4 To Read 8 bytes Insert Command 00 B0 00 00 08 Press Send T 0 APDU button 5 To Write 8 bytes 12345678 Insert Command 00 D6 00 00 0812345678 Press Send T 0 APDU button 6 To Read 8 bytes Insert Command 00 B0 00 00 08 Press Send T 0 APDU button 7 To Write 8 bytes
14. umber for the serial COM port to which the MiniSmart is connected for example 1 for COM Port 1 then click OK The COM port 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 11 of 16 Product Evaluation Guide MiniSmart Intelligent Version number can be found in the Device Manager window of the Windows system The program opens the port and detects the MiniSmart If there is a failure the program gives an error message then will exit If the port is opened successfully the program goes to the Main RS232 Demo Window as shown below Intelligetn MiniSmart Demo V1 0 RS232 File Help IDT CPU Card Quick Test Hex Read 20 Bytes Write C ASCII Generic Command Test Check Switch Send Exit Command Result 2005 2006 International Technologies amp Systems Corporation All rights reserved Page 12 of 16 Product Evaluation Guide MiniSmart Intelligent Version Buttons and Other Descriptions There are two groups of buttons the ID TECH CPU Card Quick Test group and the Generic Command Test group The group at the top of the open window is for ID TECH CPU Card P N 80005206 001 only The group below is generic and can be used for demonstration of other cards Result text box This box displays all detailed communication between the reader and the PC Hex or ASCII The radio buttons control the Result box format displayed Hex or ASCII format

Download Pdf Manuals