Models 2156 & 2157 CopperLink Ethernet Extenders User Manual

image

Contents

1. Connect the line port refer to section 3 3 Connecting the Line Port on page 12 Note See Figure 1 and Figure 2 for the rear panel connectors locations Connect the serial port refer to section 3 4 Connecting the Circuit Interface on page 12 Line El interface TX 75 Ohm Data to 1200hm 6703 6704 RX 75 Ohm network ow Data from 6 703 6 704 network Figure 1 CopperLink T Model 2113 rear panel TI interface RJ 48C Power Figure 2 CopperLink T Model 2115 rear panel 10 3 1 CONNECTING POWER The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall A be positioned within easy reach of the operator Ensure that the AC power cable meets all applicable standards CAUTION for the country in which it is to be installed and that it is connected to a wall outlet which has earth ground Your CopperLink T T1 E1 Extender comes with an external AC adaptor with a detachable power cord To connect power to the CopperLink T 1 Connect the female plug of the AC power cord to the AC adaptor provided 2 Connect the barrel type connector of the AC adaptor to the Power connector on the CopperLink T 3 Insert the male plug of the AC power cord into the AC power outlet 100 240 VAC 4 Verify that the Power LED on the front panel illuminates and remains lit 3 2 POWER INPUT CONNECTOR The CopperLink T T1 E1 Extender comes with an
2. ISO Vine An ISO 9001 Certified Company Part 07M2113 UM Doc 03331U2 001 Rev A Revised 1 17 07 USER MANUAL MODELS 2113 amp 2115 CopperLink T T1 E1 Extenders pE PATTON Bd ElectronicsTo SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 CONTENTS 1 0 1 R amp D 3 1 6 1 7 2 0 2 1 2 2 3 0 3 1 3 2 3 3 3 4 4 0 4 1 4 2 A A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 11 Warranty Information sin 4 Radio and TV Interference 4 CE Declaration of Conformity 00 eecceeeceeeeeeeseeeneeeeeeteneeeeneeeaees 4 FCC Part 68 55 Motte dats eae hasbeen ites 5 Industry Canada Notice 0 eccececeeseeeseeceneeeeeeseeeseeeeeeeteeeeeaeessas 5 Compliance istics set Perf ahaa statis cece 6 EMG inner teeta aie avait teas 6 GLC LY bes depeche tee n edhe etre hn reece Beans AS ctat 6 PSTN Regulatory ienna aati een eee 6 SETAT 5582 serein E dede E 7 Alternate Patton support for Europe Middle East and Africa EMEA anne A tated Saenz aes Saeed 7 Safety When Working With Electricity 8 General Information 9 Features sas Sea enh E nn nn ent eas 9 De SGnipDto a EE ETETE T TETTE 9 Installation sise 10 Connecting POWET 2 ois Mines dans Minute 11 Power Input Connector 11 External AC universal power Supply 11 Connecting the Line Port 12 Connecting the C
3. connector on the CopperLink T 2 Attach the other end of the cable to the serial connector on the local Ti or El 12 Note The unit marked as 2113 L or 2115 L is configured by default to accept timing from the T1 E1 circuit The 2113 R or 2115 L unit then recovers this timing from the line in order to ensure synchronization of the T1 E1 circuit over the extenders Model Number Pa PATTON HE Electronics To Gaithersburg Maryland CopperLink T T1 E1 Link Extender Power Input 5VDC 0 58 P Prod 2113 L EUI LOUER S Serial Nbr 0000000000 DL LIL y Figure 4 The label showing the specific model number on the bottom of the unit 13 4 0 OPERATION Once the CopperLink T T1 E1 Extenders are properly installed they should operate transparently No user settings required This section describes reading the LED status monitors 4 1 FRONT PANEL LED STATUS MONITORS Models 2113 and 2115 feature three front panel LEDs that monitor power Ethernet signals and the CopperLink connection Figure 5 shows the front panel location of each LED Table 1 describes the LED functions Power LED Figure 5 CopperLink T T1 E1 Extender front panel Table 1 Front panel LED description LED Description Power When lit indicates the unit is powered on Link On solid link is connected Off No signal detected Flashing Data is being transmitted received
4. Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the com pany s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above condition may not prevent degradation of service in some situa tions Repairs to some certified equipment should be made by an autho rized maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunc tions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own pro tection that the ground connections of the power utility telephone lines and internal metallic water pipe system are connected together This protection may be particularly important in rural areas 1 5 COMPLIANCE EMC FCC Part 15 Class A EN55022 Class A EN55024 Safety e UL 60950 CSA C22 2 NO 60950 IEC EN60950 PSTN Regulatory e FCC Part 68 e CS03 e TBR12 amp TBR13 e AS ACIF S031 amp S043 1 6 SERVICE All warranty and non warranty repairs must be returned
5. AC power supply e The supplies connection to the CopperLink T T1 E1 Extender is a 2 5 mm barrel receptacle with the center conductor positive see Figure 3 Power ee Figure 3 Power connection barrel receptacle diagram e CopperLink T T1 E1 Extender s rated voltage 5 0 VDC e CopperLink T T1 E1 Extender s rated current 1 A DC External AC universal power supply e Output from power supply 5 VDC 2A e Input to power supply universal input 100 240 VAC 50 60 Hz 0 3A 11 external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem perature flammability and mechanical serviceability A The interconnecting cables shall be acceptable for CAUTION 3 3 CONNECTING THE LINE PORT Follow the steps below to connect the CopperLink T line port 1 Obtain a single twisted pair cable with an RJ 45 plug connector at each end 2 Plug one end of the cable into the RJ 45 socket labeled Line on the CopperLink T 3 When the remote and local extender units synchronize the front panel Link LED will turn on 3 4 CONNECTING THE CIRCUIT INTERFACE Your CopperLink T comes with either an RJ 48C or an RJ 48C and dual BNC for connection to a T1 or E1 Model 2113 E1 120 Ohm RJ 48C and dual 75 Ohm BNC connec tors e Model 2115 T1 RJ 48C To connect the twisted pair cable to the CopperLink T serial port 1 Attach the male connector of the twisted pair cable to the female
6. CTORY DEFAULT CONFIGURATION Table 4 S2 Factory Default Dip Switch Configuration Switch 2113 L EUI 2113 R EUI 2115 L EUI 2115 R EUI Switch 2 1 OFF OFF OFF OFF Switch 2 2 OFF OFF OFF OFF Switch 2 3 OFF OFF OFF OFF Switch 2 4 OFF ON OFF ON Switch 2 5 ON OFF ON OFF Switch 2 6 OFF OFF ON ON Switch 2 7 OFF OFF ON ON Switch 2 8 ON ON ON ON 18 NOTES NOTES Copyright 2007 Patton Electronics Company All Rights Reserved 20
7. Frame On solid T1 E1 frame is connected Off No signal detected Flashing Error detected 14 4 2 CONFIGURATION AND DIP SWITCHES The CopperLink T T1 E1 Extenders are Plug n Play enabled and do not require any configuration by the user Note The user should NOT change any of the dip switches except for 1 7 if necessary If the user changes the position of any of the dip switches except for S1 7 it will affect the operation of the unit Refer to Appendix B on page 18 for the factory default dip switch configuration Switch S1 7 Line Build Out Switch S1 7 defines the shape of the waveform on the T1 or E1 line Table 2 S1 7 Default Position Switch 2113 L EUI 2113 R EUI 2115 L EUI 2115 R EUI OFF 120 OFF 120 ON 0 0dB ON 0 0dB 15 APPENDIX A SPECIFICATIONS A 1 CIRCUIT RATES Model 2113 2 048 Mbps e Model 2115 1 544 Mbps A 2 CIRCUIT INTERFACE E1 Model 2113 presents G 703 G 704 interface Either 75 Ohms unbal anced or 120 Ohms balanced Pins 1 amp 2 are Receive Pins 4 amp 5 are transmit T1 Model 2115 present T1 interface Pins 1 amp 2 are Receive Pins 4 amp 5 are Transmit A 3 CIRCUIT DEFAULTS e E1 Line Coding HDB3 e T1 Line Coding B8ZS Line Build Out Rx Automatic Line Build Out Tx 0 A 4 CIRCUIT CONNECTOR Dual BNC and RJ48C Model 2113 strap selectable e RJ48C connector Model 2115 A 5 LED INDICATORS e Th
8. direc tive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling 2 0 GENERAL INFORMATION Thank you purchasing this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for one year for parts and labor If questions arise while installing or using this product contact Technical Support at 1 301 975 1007 2 1 FEATURES Easy to install T1 E1 Extenders vo configuration required e Data rates up to 2 048 Mbps in 64 kbps intervals e Plug n Play for easy installations LED indicators for Power Ethernet Link and Frame CE marked 2 2 DESCRIPTION The Patton Electronics Model 2113 2115 CopperLink T provides high speed 2 wire T1 E1 extension connectivity to ISPs PTTs and enterprise environments using binder group friendly TC PAM modulation Line connection is made with an RJ 45 jack Models 2113 and 2115 are powered by an 100 230 VAC Universal supply The NTU features exter nally accessible DIP switches loopback diagnostics and CopperLink T Plug n Play 3 0 INSTALLATION Because the CopperLink T T1 E1 Extenders require no configuration they can be installed quickly Installation consists of the following Connect the power plug refer to section 3 1 Connecting Power on page 11
9. easures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 2 CE DECLARATION OF CONFORMITY We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999 5 EC on the approximation of the laws of the member states relating to Radio and Telecommunication Ter minal Equipment and the mutual recognition of their conformity The safety advice in the documentation accompanying this product shall be obeyed The conformity to the above directive is indicated by the CE sign on the device 1 3 FCC PART 68 This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other information a product identifier in the format US AAAEQ ETXXXX t requested this number must be provided to the telephone company The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of ser vice may be required But if advance notice isn t practical the telephone company will notify the custome
10. freight prepaid and insured to Patton Electronics All returns must have a Return Materi als Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Services at e Telephone 1 301 975 1007 Email support patton com URL http www patton com Technical support is available from 8 AM to 5 PM EST 8 00 to 17 00 UTC 5 Monday through Friday Note Packages received without an RMA number will not be accepted Alternate Patton support for Europe Middle East and Africa EMEA Telephone support Standard telephone support is available five days a week from 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT by calling 41 0 31 985 25 55 Fax 41 0 31 985 25 26 1 7 SAFETY WHEN WORKING WITH ELECTRICITY A WARNING e This device contains no user serviceable parts The equipment shall be returned to Patton Electronics for repairs or repaired by qualified service personnel e The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator Ensure that the AC power cable meets all applicable standards for the country in which it is to be installed and that it is connected to a wall outlet which has earth ground e Do not work on the system or connect or disconnect cables during periods of lightning activity In accordance with the requirements of council
11. ircuit Interface eceeeeeeeeeeeseeeeeeeeeeteeeeetees 12 OPO Vath OM sees canes cose Rs EO TTT 14 Front Panel LED Status Monitors 14 Configuration and Dip Switches 15 Switch S1 7 Line Build Out 15 Specifications reisean enion eee eemennnne lie 16 CIRCUIT RATES nn ni nement 16 Circuit Interface a a een ne ete anal em 16 Girc it Defaults ca ner hante tnt tales shine Awe 16 CireUik COMNECtOr 44 A Me A a TAS Uh 16 ED INGICAtONS sante she st verte ede eiaa ht du d 16 Power and Power Supply Specifications 0 0 0 0 cceeeeeeeeeeeee 16 Environmental sarene Aster ln a A charter aS 17 Transmission LING 4a acy an nant me su 17 Line CITING s ries dsl A in etant rene eas 17 Line Interface eines invente detente nan ds 17 Line Physical Connection 0 ec ceeeeeeeeneeeeeeetteeteeecteettetenatees 17 Factory Default Dip Switch Configuration B 1 Switch S1 Factory Default configuration B 2 Switch S2 Factory Default configuration 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 2113 or 2115 components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of the shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not performs as warranted your sole recourse shall be re
12. pair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user Note Conformity documents of all Patton products can be viewed online at www patton com under the appropriate product page 1 1 RADIO AND TV INTERFERENCE This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manu facturer s instructions may cause interference to radio and television reception This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifica tions in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installa tion However there is no guarantee that interference will not occur in a particular installation If the equipment causes interference to radio or television reception which can be determined by disconnecting the cables try to correct the interference by one or more of the following m
13. r as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equip ment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninter rupted service If trouble is experienced with this equipment for repair or warranty infor mation please contact our company If the equipment is causing harm to the telephone network the telephone company may request that you dis connect the equipment until the problem is resolved Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information 1 4 INDUSTRY CANADA NOTICE This equipment meets the applicable Industry Canada Terminal Equip ment Technical Specifications This is confirmed by the registration num ber The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicat ing that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment This Declaration of Conformity means that the equipment meets certain telecommunications network protective operational and safety require ments The
14. ree LED indicators Power Link Frame A 6 POWER AND POWER SUPPLY SPECIFICATIONS e AC power supply Connection to the CopperLink T T1 E1 Extender requires 5VDC 5 DC power 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm 1 D O D shaft length dimensions CopperLink T T1 E1 Extender s rated voltage 5 0 VDC CopperLink T T1 E1 Extender s rated current 1A DC A 7 ENVIRONMENTAL e Temperature 32 122 F 0 50 C e Relative Humidity 5 95 non condensing e Altitude 0 15 000 ft 0 4 572 m A 8 TRANSMISSION LINE e Single Twisted Pair A 9 LINE CODING TC PAM Trellis Coded Pulse Amplitude Modulation A 10 LINE INTERFACE e Transformer coupled 2500 VRMS isolation A 11 LINE PHYSICAL CONNECTION e RJ 45 2 wire polarity insensitive pins 4 and 5 APPENDIX B FACTORY DEFAULT DIP SWITCH CONFIGURATION Note This information is provided for informational purposes only These settings should not be changed other than by instructions from Patton Support lest the unit be rendered inoperable B 1 SWITCH S1 FACTORY DEFAULT CONFIGURATION Table 3 S1 Factory Default Dip Switch Configuration Switch 2113 L EUI 2113 R EUI 2115 L EUI 2115 R EUI Switch 1 1 ON ON ON ON Switch 1 2 ON ON ON ON Switch 1 3 ON ON ON ON Switch 1 4 ON ON OFF OFF Switch 1 5 ON ON OFF OFF Switch 1 6 OFF OFF ON ON Switch 1 7 OFF OFF ON ON Switch 1 8 ON ON ON ON B 2 SWITCH S2 FA