1. e Use 10 gauge 6 mm wire 1 Switch the transformer input circuit breaker and the utility circuit breaker OFF 2 Remove the access panel by removing screws see A for 4P9626 models and B for A4P9628 models 3 For AP9626 models only disconnect the power cord from the terminal blocks 4 For AP9628 models only remove circular knockouts 5 Install a flexible type conduit for input and output 4P9628 models only panels and secure 6 Run wires through the conduit 7 Connect the new wires to the terminal blocks see the terminal blocks for 4P9626 models and AP9628 models below Wire to the ground block first Each terminal block is labeled AP9626 models AP9628 models 8 Switch the circuit breakers ON 9 Check line voltages 10 Reinstall the access panel 4P9628 models or install the new hardwire access panel supplied with AP9626 models 6 APC Step Down Transformer User Manual Connecting Equipment and Power to the Transformer Connecting Equipment and Power to the Transformer Rear Panels AP9626 models Gia a Gia Wa bes OLG OLONA O00000 00000000000000000000 O OOO0O0000000000000 AP9627 models 2595262 CESOROSS 268685 oo OO00000000000 O000000000000 09092000900009 OQOQQOQQQQQQQQ OQ0000000 O00 909009009 OOO000000000 0000000000000 Start Up Attention e Wiring must be performed by a qualified electrician e Adhere to all local and national electrical c
2. American Power Conversion APC in this Statement of Limited Factory Warranty applies only to products you purchase for your commercial or industrial use in the ordinary course of your business Terms of Warranty American Power Conversion warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its sole discretion any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way Repair or replacement of a defective product or part thereof does not extend the original warranty period Any parts furnished under this warranty may be new or factory remanufactured Non transferable Warranty This warranty applies only to the original purchaser who must have properly registered the product Product may be registered at http watranty apc com Exclusions APC shall not be liable under the Warranty if its testing and examination discloses that the alleged defect in the product does not exist or was caused by your or any third person misuse negligence improper installation or testing unauthorized attempts to repair or modify wrong or inadequate electrical current or connection inappropriate on site operation conditions corrosive atmosphere repair installation start up by non APC designated p
3. 0P or 2 ft cord with L6 30P Hardwire Distribution hardwired Output Power 2 15 A circuits with 4 20 A circuits with Hardwire Distribution 4 5 20R and 2 15 A circuits 4 L5 20R with 2 5 20R 4 APC Step Down Transformer User Manual Rack Installation Rack Installation Install the Rails For details on support rail installation refer to the instructions in the rail kit Install the Transformer Attention Install the transformer directly above the UPS Install the bezel and bracket components that correspond to your specific configuration 1 e Smart UPS Smart UPS RT Symmetra Attention The bezel which corresponds with Smart UPS configurations must be installed at the same time as the brackets Smart UPS RT configurations Smart UPS configurations l configurations configurations Smart UPS RT configurations Symmetra configurations APC Step Down Transformer User Manual 5 Electrical Configuration Electrical Configuration Attention e The AP9626 and AP9627 models DO NOT require hardwiring Use the attached cord to connect to utility power For optional AP9626 hardwiring follow wiring instructions below Hardwiring Attention e All electrical configurations must be performed by a qualified electrician e Adhere to all local and national electrical codes e Verify that all branch circuit mains are de energized and locked out before installing cables or making connections
4. F SUCH DAMAGES SPECIFICALLY APC IS NOT LIABLE FOR ANY COSTS SUCH AS LOST PROFITS OR REVENUE LOSS OF EQUIPMENT LOSS OF USE OF EQUIPMENT LOSS OF SOFTWARE LOSS OF DATA COSTS OF SUBSTITUANTS CLAIMS BY THIRD PARTIES OR OTHERWISE NO SALESMAN EMPLOYEE OR AGENT OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY WARRANTY TERMS MAY BE MODIFIED IF AT ALL ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT Warranty Claims Customers with warranty claims issues may access the APC worldwide customer support network by visiting www apc com Select your country from the country selection pull down menu Open the Support tab at the top of the web page to obtain contact information for customer support in your region TAPC single phase products covered under this warranty include all Smart UPS products Matrix UPS products and all single phase Symmetra products Products purchased as part of an InfraStruXure single phase solution are covered under a separate ISXTM warranty Accessories covered under this warranty include rack power distribution units PDU Management Cards RM KVM Switch RM Keyboard Monitor and Air Distribution Fan products APC Step Down Transformer User Manual 9 Warranty and Contact Information APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Refer to the APC Web site to access documents in the APC Knowl
5. JADI BAR COD ELIN C ADBARCODE INC 637 R Parkdale Ave N Hamilton Ontario Canada L8H 521 Phone 1 888 417 7226 SCAN 1 905 312 0593 Fax 1 905 312 0958 www adbarcode com About ADBARCODE INC TOSHIBA Who We Are gt gt TEC The intelligent consumers best avenue for barcoding equipment amp supplies g Our continued aim in the data collection industry is to commit to providing the highest level of service excellent pricing and the right equipment delivered timely and efficiently Our customers have confidence in making informed purchases with no surprises AD Barcode is more than just a supplier we are your off site barcoding backup We have all the answers and resources for all your barcoding needs just try us Q MOTOROLA We re NOT just a PO Box We re the web site you can actually walk into Come by and visit our 4000 square foot facility for local or emergency pickup of thousands of supplies datamax onel Aaa Od aYeoxes A B J 010 D EN Oar g Honeywell Technical Support based on Real World Experience We actually use the products we sell If you have an issue come up in production We are here to help Our years of experience with a myriad of legacy printers labels ribbons and scanners is just a phone call away TPG Accounts We service a wide range of Industries including Automotive Warehousing invent Food Processing Healthcare and Education an TOWEHS STEWS Incredibl
6. Three front bezel kits e Rail kit e Literature kit containing e Product documentation e User Manuals CD e Safety information e Warranty information Environmental Specifications This unit is designed for indoor use only Do not operate the unit where there is excessive dust 32 to 104 F 0 to 40 C Humidity 0 to 95 relative humidity non condensing The unit is heavy Select a location sturdy enough to handle the weight APC Step Down Transformer User Manual 3 Introduction Electrical Specifications Attention e Operation above the input voltage range may cause equipment damage e Operation below the input voltage range may cause overload or automatic shutdown When connecting directly to a branch circuit check that the line voltage is within specifications When connecting to the UPS check that the line voltage into the UPS is within specifications before transferring to bypass mode Note In order for AP9626 models to output the full 5000 VA the input must be hardwired to a 5500 VA source AP9826 or AP9627 AP9626 or AP9628 For continuous operation below Vin 205 Vac the output load must be reduced to limit the maximum input current to the amount specified above Continuous operation above the maximum specified input current may cause the unit to overheat and shut down Please contact APC for additional information Not available for AP9627 AP9626 AP9627 AP9628 Input Power 3 ft cord with L6 3
7. e Value With 15 years of Industry Knowledge and Partnerships Our buying power remains Ultra Competitive with the lowest cost of ownership for the end user unitech Same Day Shipping s available to anywhere in North America on all in stock items NAVAS Intermec Best Manufacturers Our Best of Breed list of manufacturers are the backbone of our reliable Systems OSDATALOGIC Customer Service Service contracts that take away the pain of downtime EPSON bol Return Policy We have a return policy that is based on Customer Satisfaction and Customer Retention There is no fine print MANY MORE www ape com User Manual English APC Step Down Transformer Models AP9626 AP9627 and AP9I628 990 7820F 06 2006 Introduction Introduction The APC step down transformers are used to convert a higher input voltage 208 200 V to a lower output voltage 120 100 V which might be more fitting for certain environments or system configurations Note Illustrations in this document may vary from your actual configuration Unpacking Read the Safety Guide before installation Note The model and serial numbers are located on a small rear panel label For some models an additional label is located behind the front bezel Inspect the transformer upon receipt Notify the carrier and dealer if there is damage The packaging is recyclable save it for reuse or dispose of it properly Check the package contents e Transformer e
8. e interference at their own expense Regulatory Approvals GW LR63938 LISTED Service If the transformer requires service do not return it to the dealer Follow these steps 1 Contact APC Customer Support through the APC Web site www apc com e Note the model number of the transformer the serial number located on the back of the unit and the date purchased If you call APC Customer Support a technician will ask you to describe the problem and attempt to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA e Ifthe transformer is under warranty repairs are free e Procedures for servicing or returning products may vary internationally Refer to the APC Web site for country specific instructions 2 Pack the transformer in its original packaging If this is not available refer to the APC Web site for information about obtaining a new set Pack the transformer properly to avoid damage in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty Mark the RMA on the outside of the package KR WwW Return the transformer by insured prepaid carrier to the address given to you by Customer Support 8 APC Step Down Transformer User Manual Warranty and Contact Information Warranty and Contact Information American Power Conversion Limited Two Year Factory Warranty The limited warranty provided by
9. edge Base and to submit customer support requests Wwww apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information Www apc com support Global support searching APC Knowledge Base and using e support e Contact an APC Customer Support center by telephone or e mail Local country specific centers go to Wwww apc com support contact for information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright 2006 American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo Smart UPS Symmetra and PowerChute are registered trademarks of American Power Conversion Corporation All other trademarks are the property of their respective owners 10 APC Step Down Transformer User Manual
10. ersonal a change in location or operating use exposure to the elements acts of God fire theft or installation contrary to APC recommendations or specifications or in any event if the APC serial number has been altered defaced or removed or any other cause beyond the range of the intended use THERE ARE NO WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE OF PRODUCTS SOLD SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH APC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE APC EXPRESS WARRANTIES WILL NOT BE ENLARGED DIMINISHED OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF APC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES APC WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES IN NO EVENT SHALL APC ITS OFFICERS DIRECTORS AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF THE USE SERVICE OR INSTALLATION OF THE PRODUCTS WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT IRRESPECTIVE OF FAULT NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY O
11. odes e If the internal temperature of the transformer is less than 100 F one of the fans is at risk of failing If 100 F is reached the redundant fan will turn on 1 Check that all power is turned OFF 2 For AP9626 optional or AP9628 models only hardwire the transformer see Hardwiring 3 For AP9626 or AP9627 models only connect all load equipment to the PDU receptacles Note Each receptacle group is protected by a circuit breaker A colored label identifies each circuit and the corresponding breaker 4 Switch the transformer input circuit breaker ON 5 Turn on output circuit breakers as needed 6 Turn on all connected equipment APC Step Down Transformer User Manual 7 Regulatory and Service Information Regulatory and Service Information FCC Compliance Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct th