LabVIEW Real-Time Module for Mac OS X User Manual Addendum

image

Contents

1. 1 Use the Reset SCXI Configuration VI to reset the SCXI configuration stored on the RT target including all SCXI chassis SCXI module and DAQ accessory configurations 3 Note If you connected a signal conditioning DAQ accessory such as the SC 2345 directly to a DAQ device you need to call only the Create DAQ Accessory VI and the Set SC2345 Configuration VI to create the configuration file 2 Use the Create SCXI Chassis VI to create a new configuration file for the SCXI chassis 3 Use the Create SCXI Module VI to add an SCXI module to the configuration and define the connections to DAQ devices in the system National Instruments Corporation 5 Real Time Module for Mac OS X Addendum 4 Depending on the specific module you might need to configure specific module settings Use the following VIs to configure specific module settings e Set 1520 Module Settings VI e Set 153x Module Settings VI e Set 1540 Module Settings VI e Set 1126 Module Settings VI e Set SCXI Module Wire Sensor Mode VI 5 If necessary use the Set SCXI Module Gain VI to set the gain for a specific SCXI channel 6 Use the SCXI Module Filter VI to set the filter settings for a specific SCXI channel 7 Use the Create SCXI Accessory VI to add an SCXI accessory to the configuration 8 Ifthe accessory supports accessory gain settings use the Set SCXI Accessory Gain VI to set the gain of an accessory channel 9 Use the Save SCXI Configuration VI to sav
2. E LabVIEW Real Time Module for Mac OS X User Manual Addendum This addendum supplements the LabVIEW Real Time Module User Manual with information specific to running the LabVIEW Real Time Module under Mac OS X The primary difference between Windows and Mac OS X versions of the Real Time Module involves file path specifications and configuring RT targets and SCXI DAQ systems Contents Installing the SoftWare wc c c c0 s cssckevassevecbendcacvinsevas schaviesceguveaieecbebecbeveoes 1 Specifying Mac OS X File Paths 0 eee eeeeeceseeseeeeceeeeeeeeeeseeteeeeees 2 Configuring RT Targets esseeseseesssrerrerseretsreresrerrerrersrrsterrntenresreresrnne 2 Booting RT Targets into the Real Time OS ee 2 Configuring Network Settings of RT Targets s 3 Installing Software on the RT Target s s s 5 Configuring a DAQ System oo eee ee eeeceeeeceeseeseeeaeeeeeeaeeeeeaesseeeaeenees 5 Installing the Software Complete the following steps to install the Real Time Module on the host computer 1 Install LabVIEW for Mac OS X 3 Note You must log in as administrator or as a user with administrator privileges before attempting to install software 2 Insert the LabVIEW Real Time Module for Mac OS X CD into the CD ROM drive 3 Browse the CD and double click the Install LabVIEW Real Time for Mac OS X application 4 Follow the instructions to complete the installation FieldPoint LabVIEW National Instrument
3. State Unconfigured Hostname 2F0A1D33 IPaddress 0 0 0 0 Subnet mask 0 0 0 0 Gateway 0 000 DNS server 0 0 0 0 Comment optional Reboot Apply Launch File Transfer Utility Figure 1 Remote System Explorer The Remote System Explorer automatically searches the local subnet for available RT targets and displays them in the Remote Systems list If the RT target you want to configure does not appear select View Refresh to refresh the Remote Systems list You can manually add RT targets located on other subnets to the Remote Systems list by clicking the New Remote Device button located below the Remote Systems list and entering the appropriate device host name or IP address The RT target then appears in the Remote Systems list National Instruments Corporation 3 Real Time Module for Mac OS X Addendum You can configure network settings for RT targets when the device appears in the Remote Systems list Complete the following steps to configure the network settings for an RT Series PXI controller 1 Select the RT target from the Remote Systems list 2 Enter a device name in the Hostname text box located in the Device Identification section The default device name is the serial number of the RT Series hardware 3 Enter the network parameters you want to assign to the device You can either choose to assign a static IP address or have the system retrieve an IP address automatically fro
4. e the configuration to a file on the media storage device of the RT target Real Time Module for Mac OS X Addendum 6 ni com Figure 2 illustrates how to use the Config SCXI VIs to programmatically configure the components of a DAQ system Reset SCXI Configuration VI Create DAQ Accessory VI Create SCXI Chassis VI Set SC2345 Configuration VI Create SCX Module VI Set 1520 Module Settings VI or Set 153x Module Settings VI or Set 1540 Module Settings VI or Set 1126 Module Settings VI Set SCXI Module Sensor Wire Mode VI Set SCX Module Gain VI Set SCXI Module Filter VI Create SCXI Accessory VI Set SCXI Accessory Gain VI Save SCXI Configuration VI Figure 2 Programmatic Execution Flow of Config SCXI VIs National Instruments Corporation 7 Real Time Module for Mac OS X Addendum The example in Figure 3 creates a configuration file for a DAQ system with an SCXI chassis module and accessory The VI saves the configuration file to the media storage device on the RT target id False vh Figure 3 Programmatically Configuring Components of a DAQ System 323524A 01 Apr03
5. m a DHCP server A DHCP server allocates an IP address to the PXI device at startup Select Obtain IP Address from DHCP server in the IP Settings section of the Network settings tab to obtain an execution target IP address automatically from the DHCP server Use DHCP if a static IP address is not available Consult with the network administrator for more information about using DHCP Use a static IP address if the remote RT target will use the same IP after a reboot Using a static IP address ensures the proper behavior of applications that communicate with RT targets using a specific IP address Select Edit the IP settings in the IP Settings section of the Network settings tab and specify the following network parameters e IP address The unique computer readable address of a networked device Each IP address contains a set of four numbers in the range from 0 through 255 Each number is separated by a period For example 130 164 44 143 e Subnet mask A network code that helps a network device determine whether other devices are on the same network e Gateway The IP address of the gateway server The gateway server functions as a connection between two separate networks DNS server The IP address of a Domain Name Server DNS that stores host names and translates them into IP addresses You must provide a value for the IP address and Subnet mask parameters If the network of the remote RT target does not have a gateway or DNS se
6. rver set IP address and Subnet mask to the default setting of 0 0 0 0 4 Click the Apply button 5 Click the Reboot button to reboot the remote system and apply the changes Real Time Module for Mac OS X Addendum 4 ni com Installing Software on the RT Target Complete the following steps in the Remote System Explorer to install or upgrade the software on an RT target 1 Click the Software tab to display the software settings The Software tab displays the software currently installed on the host computer and on the RT target 2 Select from the appropriate pull down menu the software version to install from the host computer to the RT target Click the Install button 4 Place acheckmark in the Uninstall Software checkbox and then click the OK button to begin installation Configuring a DAQ System The Real Time Module for Mac OS X provides the Config SCXI VIs located in the vi 1ib DAQ ConfigSCXI 11b to configure signal conditioning DAQ accessories or an SCXI chassis modules and accessories in a DAQ system With the Config SCXI VIs you can programmatically configure the components of a DAQ system Use the Config SCXI VIs to programmatically configure SCXI DAQ system components or signal conditioning DAQ accessories in a DAQ system from within a LabVIEW application that runs on the RT target Complete the following steps to programmatically configure SCXI DAQ system components or signal conditioning DAQ accessories
7. s NI ni com and SCXI are trademarks of National Instruments April 2003 Corporation Product and company names mentioned herein are trademarks or trade names of their respective 323524A 01 companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD orni com patents N NATIONAL 2003 National Instruments Corp All rights reserved Printed in Ireland INSTRUMENTS Refer to the LabVIEW Real Time Module Bookshelf for information about programming deterministic applications You must have Adobe Acrobat Reader with Search and Accessibility 5 0 5 or later installed to view the PDFs PDF links do not work with the Apple Preview viewer Specifying Mac OS X File Paths When you create VIs with the Real Time Module for Mac OS X you must adhere to Mac OS convention for file paths using the LabVIEW path type LabVIEW formats the path using the standard syntax for the RT target before downloading the VI to the target The Mac OS delimiter for file paths is the colon The following is an example of a Windows file path c National Instruments LabVIEW The same file path changes to the following under Mac OS c National Instruments LabVIEW Configuring RT Targets The Real Time Module for Mac OS X does not support RT Series plug in data acquisition devices or RT Series FieldPoint devices as RT targets This section contain
8. s general instructions for configuring RT Series PXI devices as remote RT targets Refer to the specific RT Series PXI device documentation for information about installing the device Booting RT Targets into the Real Time OS You must boot RT Series PXI controllers into the Real Time Operating System RTOS before you can configure the network settings for the controller Some controllers do not have the RTOS pre installed However you can use a floppy disk to boot into the RTOS on a PXI controller that does not have the RTOS installed The Real Time Module for Mac OS X includes a disk labeled PXI Boot Disk for LabVIEW Real Time Module ver 7 Insert this boot disk into the floppy drive of an RT Series PXI controller Power on or reset the PXI controller to boot into the RTOS Real Time Module for Mac OS X Addendum 2 ni com Configuring Network Settings of RT Targets Use the Remote System Explorer shown in Figure 1 to configure remote RT targets Double click the Remote System Explorer application located in the Applications National Instruments Shared Remote System Explorer directory to launch the Remote System Explorer 0 9 Remote System Explorer Remote Systems fF Network settings software 2FOA1D33 Device Identification IP Settings Model PXI Obtain IP Address from DHCP server Serial Number 2F0A 1D33 Medit the IP settings x X New Remote Device a e MAC Address 00 80 2F 0A 1D 33 System