Home

Action Instruments Brochure HA136737U001 (14 08MB)

image

Contents

1. DC Current 1 Ch 24 VDC Excitation DC Current 1 Ch In 2 Ch Out 4 to 20mA DC 0 to 10VDC 10 to 10VDC 22 3mm A to 20mA DC 0 to 10VDC 4 to 20mA DC DC Voltage 0 5V 0 10V Isolator 22 3mm DC Current 0 1mA 0 20mA 4 20mA 0 20mA on A000 only DC Voltage 0 5V 0 10V 0 to 200mV 0448 Isolato Strain Gauge 5mV to 200mV 22 3mm ae tiie ae ae Kidna Excitation 1 10VDC 120 mA oe i AC Volts 100mV to 300V DC Voltage 0 5V 0 10V DC Voltage 0 5V 0 10V Type B 0 to 1820 C Type C 0 to 2320 C Type E 270 to 1000 C Type 4 210 to 760 C Type K 270 to 1372 C Type N 200 to 1300 C Type R 0 to 1760 C Universal Type S 0 to 1750 C alato includes 2 3 amp 4 Wire RTD Type T 270 to 390 C Pt100 Pt200 Pt500 Pt1000 200 to 850 C DC VI 2 Ch Isolated Frequency O498 lsolato Discrete to 18V Math Functions Cu 9 035 40 to 260 C Q425 0B01 Q425 0B03 Transmitter Thermocouple both 3 Wire Ni120 80 to 320 C 90mV 900mV 0 to 4000 ohms The 0498 is a DC powered DIN rail mount DC input signal conditioner The unit is fully isolated to 1800V between input out put and power Two isolated analog inputs each accept either a DC voltage or current One analog output delivers either DC bipolar voltage or unipolar current The 0498 also has a separate frequency input channel and a frequency output as well as a discrete input and output channel Q408 A000 Q408 A004 10mV to 100V 1mA to 100mA
2. Current we Limit ini ks a vA Sel aE Risener ene Alarm Dual SPDT Relay DC Voltage 0 10V WV418 Isolator 2 3 amp 4 Wire RTD Platinum RTD 200 to 600 C DC Current 0 20mA 4 20mA Copper RTD 200 to 260 C 95 adjustment in any range 95 adjustment in any range WV118 2 amp 3 Wire RTD 17 5mm Alarm Dual SPDT Relay Type B 75 to 1800 C Type C 0 to 2315 C 428 only DC Voltage 0 10V WV428 Isolator Type E 200 to 1000 C DC Current 0 20mA 4 20mA Type 4 210 to 760 C 95 adjustment in any range Thermocouple Type K 200 to 1370 C Type N 200 to 1300 C 428 only Type R S 0 to 1760 C WV128 Limit Alarm Type T 200 to 390 C Alarm Dual SPDT Relay DC Voltage 0 10V WV438 Isolator Potentiometer 100 ohms to 100k ohms DC Current 0 20mA 4 20mA 95 adjustment in any range DC Voltage 0 10V WV448 Isolator Strain Gauge o i o PE DC Current 0 20mA 4 20mA 95 adjustment in any range DC Voltage 0 10V WV468 Isolator oo o DC Current 0 20mA 4 20mA AC Volts 95 adjustment in any range AC Current WV168 n oe 17 5mm Alarm Dual SPDT Relay DC Voltage 0 10V WV478 Isolator Frequency 2Hz to 10kHz 12 7mm DC Current 0 20mA 4 20mA 95 adjustment in any range AC Power 85 to 265VAC 50 to 60Hz WV905 Power Supply 120 to 300VDC 24VDC 500mA W CI16 Communications DC Power 22 5mm Config summary editing diagnostics alarm setup status e mail Interface process variable viewing data logging 95 adjustment
3. DC Voltage 0 10V DC Current 0 20mA 150mV 1 5V 15V 150V 2 5mA 25mA 2Hz to 10kHz 150mVp to 150Vrms DC Voltage 0 10V 10V DC Current 0 20mA Frequency 0 to 10kHz Discrete to 18V Add Subtract Multiply Divide Square Root Type J 0 to 500 F Type tO to 500 C DC Voltage 0 10V The Q498 can perform single or double input math calculations on the input values The available operators are Addition Subtraction Multiplication Division Square Root and Average Process control functions include Hi Lo Select Rate of Change Limiter and Track amp Hold The frequency input can also have the math functions applied A 25 point Linearisation function is available for Channel 1 Analog input only All output math and process control functions require C698 0000 software www eurotherm com actionio Iso ig oe a gi pe FF oa o fl a Ca R ae ow E T la N E j Al m Ge Ge om if Deon ie AV Cf J ig I IVI J SiN L One ting 2 Wire Transmitter for Pt100 RTD Thermocouple amp mV Programmable Isolating Universal Input 2 Wire Transmitter T A A Da EJF H il A 4 i Miniature Thermal Head Mounted 1000VDC Input to Output Isolation Cost Effective Fixed Inputs Eliminates Ground Loops Hinged Cover Protects Potentiometers Embedded Terminals PC Based User Friendly Configuration 2000VDC Input to Output Isolation Universal Input Reduces Inventory Custom L
4. 498 IQRL 2xxx required IORL Dxxx e T for AC power for DC power C680 0001 distribution distribution ee Config Tools Config Tools Athan available available p Wide Ranging Input Intrinsic Safety Intrinsic Safety Math Capability Models www eurotherm com actionio Models DIN Rail Mount Signal Conditioners Isolators Alarms amp Power Supplies Ethernet Connectivity to Most Client Software Built In Web Browser with Email and Logging Capability PC or Button Setup and Calibration A I a E Smart Power Technology Automatically Adjusts Power High Density Modules E Reduced Wiring with Jumpers Transferring Power from Module to Module E Removable Connectors Fast Response and High Accuracy In Process Calibration Isolation 1800VDC or peak AC between input output and power Operating Humidity 15 to 95 45 C Temperature Range Operating 0 to 60 C The Ultra SlimPak II Series can function as traditional stand Storage 20 to 85 C alone limit alarms and isolators or they can simultaneously be Power Consumption LOW toem connected to your company s intranet to monitor your signals Supply Ranges o to 30vVDC via a standard browser when coupled with the optional WVC16 Agency Approvals UL CSACE b WV408 428 only Class 1 Div 2 Gp A B C D to 60 C ambient DC Voltage 0 10V W408 Isolator 7 a Ai te e DC Current 0 20mA 4 20mA DC Volts 95 adjustment in any range funn
5. 62 9801 E info eurotherm au invensys com AUSTRIA Vienna Eurotherm GmbH T 43 1 7987601 F 43 1 7987605 E info eurotherm at invensys com BELGIUM amp LUXEMBOURG Moha Eurotherm S A N V T 32 85 274080 F 32 85 274081 E info eurotherm be invensys com BRAZIL Campinas SP Eurotherm Ltda T 5519 3707 5333 F 5519 3707 5345 E info eurotherm br invensys com CHINA Eurotherm China T 86 21 61451188 F 86 21 61452602 E info eurotherm cn invensys com Beijing Office T 86 10 5909 5700 F 86 10 5909 5709 10 E info eurotherm cn invensys com FRANCE Lyon Eurotherm Automation SA T 33 478 664500 F 33 478 352490 E info eurotherm fr invensys com GERMANY Limburg Eurotherm Deutschland GmbH T 49 6431 2980 F 49 6431 298119 E info eurotherm de invensys com Copyright Eurotherm Limited 2011 www eurotherm com INDIA Mumbai Invensys India Pvt Ltd T 91 22 67579800 F 91 22 67579999 E info eurotherm in invensys com IRELAND Dublin Eurotherm Ireland Limited T 353 1 4691800 F 353 1 4691300 E info eurotherm ie invensys com ITALY Como Eurotherm S r l T 39 031 975111 F 39 031 977512 E info eurotherm it invensys com KOREA Seoul Invensys Operations Management Korea T 82 2 2090 0900 F 82 2 2090 0800 E info eurotherm kr invensys com NETHERLANDS Alphen a d Rijn Eurotherm B V T 31 172 411752 F 31 172 417260 E info eur
6. Invensys Eurotherm Action Instruments Product Guide Setting the standard Eurotherm Flexible Solutions For over 35 years Eurotherm has built an international reputation for developing premium quality fit for purpose products and solutions The Eurotherm brands Action Instruments Barber Colman Chessell Continental and Eurotherm have long been recognised as the leaders in the industrial automation market Action Instruments provides the signal conditioning industry the highest quality most innovative solutions to remote signal conditioning and isolation applications Action defined the standard for accuracy and reliability and our focus on technological innovation continues to raise that standard The people behind the Action Instruments brand are devoted to understanding your needs and overcoming obstacles to the collection and transmission of industrial automation process signals Every Action product is designed for easy installation operation and maintenance Whether you are amplifying or splitting signals conditioning sensor outputs isolating grounding problems or adding more drive to current loops Action s complete product selection provides simple convenient solutions to any analog signal conditioning need Reliable signal processing under harsh conditions That s what Action s products deliver Nearly three decades of proven success can assure you of our adherence to the highest quality
7. ces incorporate TouchCal technology which simplifies PURO See be We ees calibration and allows more than 90 adjustment of zero and span Oe OVDE min K500 Agency Approvals UL CSA CE Input Span Field Configurable ae Output Field Configurable a DC Volts 10mV to 200V Alarm Dual SPDT Relay Pt100 Pt500 Pt1000 50 to 850 C a Cu10 Cu100 200 to 260 C Q116 Limit Alarm 3 Wire RTD Ni120 30 to 320 C 22 3mm_ Alarm Dual SPDT Relay NiFe604 200 to 240 C Type B 0 to 1820 C Type C 0 to 2320 C Type E 270 to 1000 C Type 4 210 to 760 C Q126 Limit Alarm Thermocouple Type K 270 to 1372 C 22 3mm Alarm Dual SPDT Relay Type N 200 to 1300 C Type R 0 to 1760 C Type S 0 to 1750 C Type T 270 to 390 C Q403 1L08 DC Volts O to 10V 4 to 20mA DC OQ403 1L09 Malo DC Volts O to 10V 22 3mm O to 10VDC 0403 1L28 DC Volts 10 to 10V l 10 to 10VDC Q403 2L00 DC Current 2 Ch 4to 20mA 4 to 20mA DC DC Voltage 0 5V 0 10V 0 to 10mV up to 0 to 200mV f 5mV up to 200mV DC Voltage 0 5V 0 10V ia pola le AHDE 50 adjustment any range i DC Current 0 1mA 0 20mA 4 20mA Excitation 1 10VDC 120 mA AC Volts 50mV to 300V DC Voltage 0 5V 0 10V DC Voltage 0 5V 0 10V DC Current 0 1mA 0 20mA 4 20mA See thermocouple types above Pt100 Pt200 Pt500 Pt1000 200 to 850 C ne Cu 9 035 40 to 260 C Sous rent niversa Ni120 80 to 320 C oltage U ee Isolate includes 2 3 amp 4 W
8. for the signal output A four wire transmitter can be either AC or DC powered Four wire transmitters provide a powered output either a voltage signal e g 0 10V 1 5V a current signal e g 4 20mA 10 50mA or in some cases a relay e g solid state or contact closure Four wire transmitters require a power supply they do not use power from the input or output signal lines The power supply allows four wire transmitters to power their output signal Because of this they are often used to boost signal strength for retransmission Process Site Control Room 700 meters Thermocouple Junction 4 20mA Digital Indicator A two wire transmitter is powered by the same two wires that carry the output signal A two wire transmitter is always DC powered and the output can only be a current signal typically 4 20mA or sometimes 10 50mA The two wire transmitter is considered a field device and requires very little power milliwatts It is therefore appropriate for hazardous explosive environments such as chemical refineries and pharmaceutical plants The low DC power requirement which ranges from 10 48VDC at currents as low as 4mA reduces the chances of an electrical spark causing ignition of flammable vapours or dust Additionally two wire transmitters save on wire costs since both the signal and power are on the same wires Locating a two wire transmitter as far as 2000 feet from the control room is possible and at half the wiri
9. in any range www eurotherm com actionio DIN Rail Mount Signal Conditioners Isolators amp Alarms Field Configurable Wide Ranging High Density DIN Rail Mount ASIC Based Design for Maximum Reliability je Aa i lt heee iere we 4 Isolation 1800VDC between input output and power except G438 Operating Humidity 15 to 95 45 C Temperature Range Ultra SlimPaks are high density DIN Rail mount setpoint limit Operating 0 to 55 C alarm and isolating signal conditioner modules All Ultra SlimPak Storage 25 to 70 C modules utilise Action s advanced ASIC based design for field aie Consumption 15W typical IEN ma g configurable input and output flexibility Supply Range 9 to 30VDC except G448 is 18 to 30VDC Agency Approvals UL CSA CE G408 DC Voltage 0 5V 0 10V _ DC Volts 10mV to 100V idimi DC Current 0 1mA 0 20mA 4 20mA DC Current 1mA to 100mA 408 1001 1001 DC Voltage 5 to 5V 10 to 10V 10mV to 200V Platinum 100 500 1000 Ohm with 16 ranges from 200 to 600 C down to 18 to 50 C DC Voltage 0 5V 0 10V Isolator DC Current 0 1mA 0 20mA 4 20mA 3 Wire RTD Copper 10 25 100 Ohm with 9 ranges from 200 to 260 C down to 18 to 50 C Limit Alarm Alarm Dual SPDT Relay 50 adjustment in any range Type B 500 to 1820 C Isolator Type E 150 to 1000 C Type 4 200 to 750 C DC Voltage 0 5V 0 10V DC Current 0 1mA 0 20mA 4 20mA Therm
10. inearisation for Special T C Types and Math Single or Dual Inputs DIN Rail Mounting Adapter Included Input Types Thermocouple RTD mV B E J K L N R S T Pt 100 2 wire or 3 wire 100mV max Input Span Thermocouple RTD mV 5mV min span 20 C min 500 C max omV min span Adjustability 15 for both zero amp span Output Span A 20mA limiting lt 28mA Isolation 1000VDC Supply Voltage 10 to 40VDC polarity protected Operating Temperature 20 to 70 C Agency Approvals CE Specify T280 1xxx C F T280 2xxx tc type C F for RTD Input for thermocouple Input T280 3xxx for mV Input Accessories T25H 0000 Headmount enclosure 1 2 NPT for thermowell and conduit AP9046 ActionPak 24 40VDC 65mA Loop Power Supply Input Types Thermocouples RTD DC mV Potentiometers Resistance Infrared Most standard types amp all special types using customer defined tables amp polynomials 2 3 amp 4 wire Pt 100 Ni 110 Ni 120 and other RTDs Includes Callandar Van Dusen adaptation and custom sensors Linearisation with user defined tables and polynomials 10 to 100mV 0 to 20k Ohms 0 to 400 Ohms Minimum Range Output 2mvV 4 20mA Supply Voltage 9 A0VDC no load polarity protected Operating Temp lsolation Calibration 40 to 85 C 2000VDC input to output Unit includes all calibration para
11. ire RTD i DC Current 0 20mA 90mV 900mV O to 4000 ohms www eurotherm com actionio Q406 A000 DC VI 1 Ch Q406 A001 DC VI 1 Ch 24VDC Excitation ad ona iON DC Voltage 0 5V 0 10V Q406 A002 Isolators DC VI 1 Ch In 2 Out AmA tot SOO 22 3mm DC Current 0 1mA 0 20mA 4 20mA Q406 A003 DC VI 1 Ch In 2 Out 24VDC Excitation 0 20mA n a on dual outputs Q406 A004 DC VI 2 Ch Part Number Function Q500 1B00 Input Housing 0Q500 2B00 Loop Powered DC Current 2 Ch 0 4 to 20mA 22 3mm 0 4 to 20mA DC 0500 4B00 Transmitters DC Current 4 Ch Output O to 1mA 0 to 20mA 4 to 20mA 0 to 50mV 0 to 100mV 0 to 500mV pop OWeIES 0 to 1V 0 to 5V 1 to 5V 0 to 10V 0 to 100V Sem Aken Transmitters 10V Pt100 0 to 100 C 0 to 150 C 0 to 200 C 0 to 250 C 0 to 500 C DC Current 1 Ch Q501 1Bxx Q501 2Bxx Output Loop Powered Transmitters Q510 0Bxx Q510 4Bxx 4 to 20mA DC 4 to 20mA DC 0 to 200 F 0 to 300 F 0 to 400 F O to 500 F 0 to 1000 F Output Type 4 0 to 500 F 0 to 1000 F O to 500 C Loop Powered Thermocouple 2Ch Type K 0 to 500 F 0 to 2000 F 0 to 1000 C Transmitter Type T 0 to 500 F 0 to 250 C Q520 0Bxx 0 DC Volts 10mV to 200V Q404 2L08 OQ404 2L09 0 to 10V O to 10V 0404 2L28 0404 3L00 Q404 3L01 Q404 4L00 10 to 10V 4 to 20mA 4 to 20mA 4 to 20mA DC Volts 2 Ch DC Volts 2 Ch T E DC Volts 2 Ch DC Current 1 Ch 24 VDC Excitation
12. l 20 to 29VDC VAC Programmable Latching Non Latching IP65 Front Panel with Tactile Configuration Buttons Specify Specify V108 ALGNVH 1 8 DIN Green LED Display 85 264 VAC PS V408 ALGNVH 1 8 DIN Green LED Display 85 264 VAC PS V108 ALRDVH 1 8 DIN Red LED Display 85 264 VAC PS V408 ALGNVL 1 8 DIN Green LED Display 20 29VDC VAC PS V116 ALVH 1 16 DIN Green LED Display 85 264 VAC PS V408 ALRDVH 1 8 DIN Red LED Display 85 264 VAC PS V116 ALVL 1 16 DIN Green LED Display 20 29VDC VAC PS V408 ALRDVL 1 8 DIN Red LED Display 20 29VDC VAC PS V132 ALVH 1 32 DIN Green LED Display 85 264 VAC PS V132 ALVL 1 32 DIN Green LED Display 20 29VDC VAC PS Accessories SUB2K D5 2nd Input Accessories SUB2K D DC Retran SUB2 1V1 O to 10V Input Adapter SUB2K R4 Form C Relay SUB2 1R7 External Relay V116 and V132 only SUB2K TK Triple Contact Input SUB2K TL Triple Logic Input All units ship with mounting brackets a 2 49 ohm shunt resistor and a SUB2K TP Triple Logic Output user manual SUB2K RR Dual Relay SUB2K LR Logic Relay SUB2K A2 232 Communications SUB2K F2 422 Communications SUB2K Y2 485 Communications SUB2K MS 24VDC 20mA Excitation SUB2K G3 5VDC Transducer Excitation SUB2K G5 10VDC Transducer Excitation All units ship with mounting brackets a 2 49 ohm shunt resistor and a user manual www eurotherm com actionio AUSTRALIA Melbourne Invensys Process Systems Australia Pty Ltd T 61 0 8562 9800 F 61 0 85
13. meters performs periodic zero and span self test and auto calibration Agency Approvals CE Specify 1 Model T287 0000 2 Model C680 0001 Isolated Communications Adapter Configuration and Calibration Software and User s Guide Accessories T25H 0000 Headmount enclosure 1 2 NPT for thermowell and conduit AP9046 ActionPak 24 40VDC 65mA Loop Power Supply C680 0002 Zero Span Trimmer www eurotherm com actionio Temperature Process Indicators Universal Temperature Pressure Process Indicators Field Configurable Input for Thermocouple RTD mV and E Universal Field Configurable Input for Thermocouple RTD mA mV and mA Bridge and 0 to 10V Signals 3 Field Configurable Alarm Setpoints with 1 or 2 Alarm E Modular Design Provides 3 Option Slots plus 1 Optional Outputs Modbus Communications Slot Bright Green 4 Digit 9999 LED Display Programmable for p Engineering Units Option Modules for 2nd Input DC Retran Sensor Excitation 3 Digital Inputs Outputs and Relays Combination Alarm Functions Alarm Blocking and E 4 Field Configurable Setpoints Support Combination Alarm Functions Rate of Change Deviation Alarms Alarm Blocking and Latching Non Latching Standard Power Supply 85 to 264VAC 48 to 62Hz IP65 Front Panel with Plug In from Front Design for Quick or Optional 20 to 29VDC VAC n a on V108 Replacement Standard Power Supply 85 to 264VAC 48 to 62Hz or Optiona
14. ne United Arab Emirates Uruguay Uzbekistan Venezuela Vietnam Yemen Zambia Zimbabwe Invensys Operations Management
15. ng cost of a four wire transmitter It is important to note that two wire transmitters can be isolated or non isolated Many low cost Control Room DC Supply ISS 7 o ZN LA Process Site line Power 700 meters Q520 4 20mA Thermocouple Junction Digital Indicator two wire transmitters are not isolated which makes it important to ensure that the input sensor is not grounded All of Action s two wire transmitters are fully isolated Members of this group include the TransPak series and most of the Q5xx products Limit alarms are considered a four wire transmitter since they have two wires for power and at least two wires for the relay signal output Limit alarms are similar to a thermostat On your thermostat at home you may have the temperature set to a cozy 72 F or 23 C If the room temperature falls below that setpoint the heater will turn on This is an example of on off control A limit alarm performs the same function It has a setpoint which is compared to a process signal If the temperature gets too high the limit alarm is used to alert an operator or shut down the process Other applications include limit alarms that can also act as backup for a control system to perform a controlled shutdown process in order to prevent damage or other hazards Digital indicators or panel meters will also accept direct sensor inputs For the most part AC powered indicators can be considered a four
16. o any standard process signal Noise Filtering a Isolators incorporate low pass filters that eliminate high frequency EMI RFI and unwanted signals from power lines generators and motors Linearisation x Many sensors output a signal that is not linearly related to the engineering value being measured For example a thermocouple used to measure temperature has a nonlinear millivolt output A thermocouple input signal isolator translates this to a standard robust linear signal such as 4 to 20mA Limit Alarms Limit alarm units take in a process signal and compare it to one or more setpoints They then provide an output signal usually a relay contact when the signal crosses the setpoint Isolators that can perform addition subtraction multiplication division square root and averaging www eurotherm com actionio Signal conditioners are electronic instruments used in factory or machine automation They can amplify convert boost transform buffer filter alarm and isolate process control signals There seems to be no limit to the variety of things control engineers want to do with control signals Signal conditioners are known by many names converters transducers isolators transmitters and black boxes Conventionally most signal conditioners and isolators fall into two categories based on the number of wires required for power and signal A four wire transmitter has two wires for power and two wires
17. ocouple Type K 200 to 1370 C Type R S 50 to 1760 Limit Alarm Type T 150 to 400 17 5mm Alarm Dual SPDT Relay DC Voltage 0 5V 0 10V Isolator Potentiometer 100 ohms to 100k ohms 12 6mm DC Current 0 1mA 0 20mA 4 20mA 0 to 200mV Isolator Strain Gauge 5mV to 200mV ie een 4 20mA Excitation 1 10VDC 120 mA ai l 50mV AC to 250VAC DC Voltage 0 5V 0 10V Isolator 12 6mm 50mA AC to 100mA AC DC Current 0 1mA 0 20mA 4 20mA AC Volts AC Current oan 50mV AC to 250VAC as Limit Alarm 50mA AC to 100mA AC 17 5mm Alarm Dual SPDT Relay DC Voltage 0 5V 0 10V G478 Isolator Frequency 2Hz to 10kHz 12 6mm DC Current 0 1mA 0 20mA 4 20mA w5 o Power Supply 100 to 240VAC 50to 60Hz o to 240VAC 50 to 60Hz 24VDC 500mA www eurotherm com actionio DIN Rail Mount Signal Conditioners Isolators amp Alarms Multi channel Conditioners Two Wire Transmitters SnapLoc Terminal Blocks Removable Connectors Interlocking Modules Optional I Q Rail Power Bus PC Based Setup Math Modules Isolation 1800VDC or peak AC between input output and power Operating Humidity 15 to 95 45 C Temperature Range Operating 0 to 55 C Storage 25 to 70 C The Actionl O Series of signal conditioners have wide ranging power e ampo eco Wee field configurable inputs and outputs These DC RTD T C sappy Range EA een renee Soe oe potentiometer bridge strain gauge AC and frequency input Pe ER SPERARE FE tee a devi
18. otherm nl invensys com POLAND Katowice Invensys Eurotherm Sp z o o T 48 32 7839500 F 48 32 7843608 7843609 E info eurotherm pl invensys com SPAIN Madrid Eurotherm Espa a SA T 34 91 6616001 F 34 91 6619093 E info eurotherm es invensys com SWEDEN Malmo Eurotherm AB T 46 40 384500 F 46 40 384545 E info eurotherm se invensys com SWITZERLAND Wollerau Eurotherm Produkte Schweiz AG T 41 44 7871040 F 41 44 7871044 E info eurotherm ch invensys com UNITED KINGDOM Worthing Eurotherm Limited T 44 1903 268500 F 44 1903 265982 E info eurotherm uk invensys com U S A Ashburn VA Invensys Eurotherm T 1 703 724 7300 F 1 703 724 7301 E info eurotherm us invensys com ED64 Represented by Invensys Eurotherm the Eurotherm logo Chessell EurothermSuite Mini8 Eycon Eyris EPower nanodac Foxboro and Wonderware are trademarks of Invensys plc its subsidiaries and affiliates All other brands may be trademarks of their respective owners All rights are strictly reserved No part of this document may be reproduced modified or transmitted in any form by any means nor may it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates without the prior written permission of Eurotherm Limited Eurotherm Limited pursues a policy of continuous development and product improvement The specifications in thi
19. s document may therefore be changed without notice The information in this document is given in good faith but is intended for guidance only Eurotherm Limited will accept no responsibility for any losses arising from errors in this document Part No HA136737U001 Issue 3 REV 1 August 2011 Eurotherm is also represented in the following countries Afghanistan Albania Algeria Angola Argentina Armenia Azerbaijan Bahrain Bangladesh Barbados Belarus Bermuda Bolivia Bosnia and Herzegovina Botswana Brazil Brunei Darussalam Bulgaria Cambodia Cameroon Canada Central African Republic Chad Chile Colombia Congo Costa Rica C te d lvoire Croatia Cyprus Czech Republic Denmark Djibouti Ecuador Egypt El Salvador Eritrea Estonia Ethiopia Fiji Finland Georgia Ghana Greece Greenland Guinea Hungary Iceland Indonesia Irag Israel Jamaica Japan Jordan Kazakhstan Kenya Kuwait Kyrgyzstan Laos Latvia Lesotho Libya Lithuania Macedonia Madagascar Malaysia Malta Micronesia Moldova Morocco Mozambique Myanmar Namibia Nicaragua Niger Nigeria Norway Oman Pakistan Palestinian Territory Papua New Guinea Paraguay Peru Philippines Poland Qatar Romania Russia Rwanda Saudi Arabia Senegal Serbia and Montenegro Sierra Leone Singapore Slovakia Slovenia Somalia South Africa Sri Lanka Sudan Swaziland Syria Tajikistan Tanzania Thailand The Gambia Tunisia Turkey Turkmenistan Uganda Ukrai
20. standards and the best in manufacturing techniques Action products are in tune with the industrial environment the real world of hard hats forklifts and EMI RFI they are ruggedised to survive the extremes of vibration shock temperature and humidity that are common to the manufacturing arena We know how tough it is on the plant floor and we realise that every application has different requirements That s why Action s solutions are tailored to your problems Experienced knowledgeable and friendly engineers are available throughout the world to answer your questions Our goal is to be your exclusive supplier for industrial measurement and control products What can we offer you Plenty What do Action Products Do Isolation A ground loop can occur if more than one ground connection is made to a single control signal Because grounds are seldom at the same potential an unwanted current will be generated and interfere with the control signal Signal isolators break the ground loop current path and maintain the integrity of the measurement lilr Signal Conversion Industrial applications use a wide array of sensols tO measure temperature flow length speed frequency etc These signals may then need to be converted into a form usable by the instrumentation to which they are connected Any sensor signal thermocouple RTD DC voltage DC current AC voltage frequency resistance etc can be converted t
21. wire transmitter if they are configured with an analog or relay output Indicators are most commonly used to display process variables however some have secondary functions such as a 4 20mA transmitter output limit alarm or relay contact closure output www eurotherm com actionio Product Selection Guide Ultra SlimPak II Ultra SlimPak Input Type Limit Signal Limit Signal Alarms Conditioners Alarms Conditioners DC Volts WV1 WV4 1 G408 DC Current oe K oie RTD WV118 WV418 G118 G418 Thermocouple WV128 WV428 G128 G428 Potentiometer WV438 G438 Strain Gauge WV448 G448 AC Volts WV1 WV4 G168 G468 AC Current a o8 Frequency WV478 G478 Accest ries Configuration Configuration Tools available Tools available 24VDC H910 H910 i W9 WV905 Power Supplies i H915 H915 Other Ethernet Connectivity PC and Button Setup Removable Connectors Fixed Connectors www eurotherm com actionio AC DC Loop Powered oT PER 2 Wi Digital Limit Alarms and Limit Alarms and 2 3 Wire Transmitters eaii ae Sei Signal Conditioners Signal Conditioners amp Signal Conditioners pasy 0108 V108 V116 Q106 Q500 V132 V408 C403 Q406 0404 Q408 Q501 12801287 0498 dedka O116 V108 V116 0486 0488 Q510 1394287 V132 V408 O126 0488 Q425 GOTZON V108 V116 0486 Q520 V132 V408 Q436 0438 T2 V408 0446 0448 V408 Q466 Q468 0478 Q476 0

Download Pdf Manuals