Home

Program pro prohlížení a ukládání naměřených dat z

image

Contents

1. file in the instrument Once measurements are completed the user transmits the measured data to the PC by means of the A4000BDL program and saves them in a file The file is then sent back to the site where the DDS2000 program is installed and the data file is imported downloaded to the DDS2000 database The A4000BDL program thus enables to separate the site where the DDS2000 database is installed from measuring instruments The use of this program is advisable for instance in assistance organisations where there are several measuring instruments Their users can send currently measured data do the central database The A4000BDL program enables a remote collection of measured data This manual does not include information on the Adash 4100 4200 instruments such as technical parameters instructions manual etc For such information see the user s manual of a particular instrument The A4100 4200 instruments can be divided in respect of measured data storing into memory in three groups See User s Manual of the Instrument Instruments without a memory Such instruments do not offer the F2 key in their main menu and do not enable to store measured data into memory and to further process them in other programs Instruments with a memory for off route measurements storing F2 Memory Such instruments enable to store measured data to their memory and to save them in a file on PC and to import them to the DDS2000 program using the A4000
2. BDL program Instruments with a memory for route and off route measurements storing F2 Route Such instruments enable if used with the A4000BDL program to import routes and to export data into a file Tee 40 12 12 2004 On Ling Aas J Baching Balancing Fogta About Instron Insktruwent Sokup Fig Main menu of the instrument with a route memory Program Installation If your PC allows auto run from the CD ROM drive the viewer starts automatically from the CD ROM after it is inserted you can launch the installation from the menu that appears on the monitor screen after inserting the installation CD ROM into the drive Click on Software installation in the next bookmark called Product installation click on A4000BDL installation Complete the installation following instructions of the installation program 3 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL If the installation menu does not appear automatically after inserting the installation CD ROM into the drive start the start exe file which is in the main directory on the installation CD ROM for instance by clicking on This Computer and then on the CD icon where you find the start exe file Installation of the HASP Key The A4000BDL program is protected against unauthorised use by the HASP key To be able to use t
3. ON Without respecting all the above mentioned conditions the computer is not able to communicate with the instrument 6 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL If these conditions are respected click on Search instrument If AUTO is set in the serial port selection field the A4000BDL program automatically searches through all available serial ports and detects the connected instrument If you select a particular port in the serial port selection field the program only detects the instrument on that particular port If the program finds the instrument it displays information on the serial port where the instrument is found and enables buttons for data transmission between the PC and the instrument x com 2 SN 620000 Version 1 05 Instrument 44000 founded on COM 2 A Exit Route Loading from the File to the Instrument Click on the button representing data transmission from the PC to the instrument In the next dialogue box select the route file extension a4r this file is created by the DDS 2000 program By confirming your selection in the dialogue box the route transmission to the instrument starts The route transmission to the instrument is completed once the following information is displayed The xxx a4r files was successfully loaded D
4. User s Manual A4000BDL Application 7 A simple program enabling transmission of route measurement files from the DDS 2000 program to the Adash 4100 4200 instruments 7 A simple program enabling transmission of measured data from the Adash 4100 4200 instruments to a file for further use in the DDS 2000 program Characteristics 7 Hardware requirements Intel Pentium or compatible CD ROM 64 MB RAM 1 MB free HDD space SVGA or a higher resolution monitor min 800x600 256 colours lt 7 The program is intended for the Microsoft Windows 95 98 NT 2000 XP operating programs Ref 07042003 JC ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL Contents PROLACG caaniiaaccecdet eceetiniuiaaysanadiiadedata iandaclentuswbiantidevudasaadaalteacaturedades dents Aiamaa Aasin aaa aiaee adaa 3 Program Installaatio Mnai e naiaiae aana ic a aA chest baad sate Eaa AASTANE Pani 3 Installati n of the HASP KEY oreiro nea haa a E E EAA 4 Program Uninstallation te s2ice ceiceeaesvelecseactecnagniedaadeiiasceans EARE aaa PENETER ets a Aai vets 4 Unistallation of the HASP Key ss cscioascuneceuid esdumeaeeetanaasidaekayiastar eared hacatiaace stunt boueialonuenteedet 4 Prior to the Program mitt elitr lt ssshos eect ulescay caved eaigeden th ete esa cal Salad crepe era ata an eae 5 Pro
5. ata Downloading from the Instrument to the File Click on the button representing data transmission from the PC to the instrument In the next dialogue box select the location and name of the file to which data will be stored file extension a4r By inserting the information and confirming in the dialogue box data transmission from the instrument to the file starts x Find instrument com 2 SN 620000 Version 1 05 0 7 status OK a ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL CAUTION This operation may take several minutes Information on the progress of the transmission and its status is displayed in the bottom part of the program window Data transmission is completed once the following information is displayed The xxx a4x file was successfully stored Finishing Work in the Program To finish work in the program click on button Exit Error Conditions of the Program If the HASP key is not connected or is connected incorrectly the program displays the following A4000BDL xi 3 Wrong or missing HW key application will not be started warning Make sure that the correct HASP key is connected to the PC parallel port or that the HASP key driver is installed correctly see chapter HASP Key Installation If data downloading from th
6. e instrument to the file fails the program displays the following warning OOOO hl 3 Data transfer From instrument was False file will be not created Receive timeout This error may be caused by the failure of communication with the instrument e g by communication cable interruption or if the instrument was off during communication or was not in the main menu the instrument communicates on serial interface only if it is in the main menu 8 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz
7. gr OONO i 2500 oss Src aca aa ae a csc a et ae ea eae ee et 6 PROGran ANS ATION sick cass pat epee nee a eds Reema E eee 6 Description of the User Interface iticic g siucsecetkseedssievaslichaccttazenens etecoethcnehaapcrede chodagebvandewestentness 6 Starting Communication with the Instrument ce cece eee eeeeeeeeeeeeeeeeeeeaeeeeeeeceeeeeeeeneeeees 6 Route Loading from the File to the Instrument eee eeeeseeeeeeeceeeeeeeeeseneneeeeeeeeeeeesesenenees 7 Data Downloading from the Instrument to the File eeseeeeeeeeeesseseerrrrresssrrerrrrrssssreerens 7 Finishing Work in the Program gas casket accion du onea yids setyacdetvetaa allow SUban A bartedeas Vode anand Oe 8 Error Conditions of the Prograinsccisseccntcessteceetevs stetnaledsczetaaveledeeteas ale cdeseusaciaebebineetaadtiiadniedes 8 2 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL Preface The A4000BDL program brings new possibilities of measured data processing and working with the empty route structure It is not necessary any more to physically connect the DDS2000 program with the A4100 A4200 instruments The DDS2000 program can export any route into a file and the file can be sent by e mail to the place of measurement at any distance The user that performs measurements uses the A4000BDL program and downloads the route
8. he A4000BDL program first install the key on your PC Proceed according to the following instructions Connect the HASP key which is part of the delivery to the parallel port a wide connector often used to connect printers on your computer Inthe installation CD ROM menu click on Software of third parties in the next bookmark click on Installation of HASP driver The installation of the HASP key driver starts once it is completed successfully a message appears This operation was completed successfully ATTENTION this operation may take several minutes Program Uninstallation Uninstall the A4000BDL program from your PC in the following way 1 If you run the A4000BDL application close it 2 Double click on Add or remove programs in Control panels Control panels are located in the Start menu folder Setting 3 Inthe open window find and select by clicking the A4000 application 4 Click on Change or remove uninstallation is launched 5 After being asked whether to remove the selected application and all its components completely click on Yes the application will be uninstalled 6 Close the Add or remove programs window The above described procedure exactly corresponds to the manner of uninstallation in the Windows 2000 operating system The procedure in the Windows NT 98 95 operating systems is similar however there are differences in the description of some keys or in the names of windows or in the graph
9. ic display of information The A4000BDL program can also be uninstalled by re launching the installation program The installation program auto detects the installed version and offers its uninstallation Uninstallation of the HASP Key The uninstallation of the HASP key is very similar to its installation Please proceed according to the following instructions 4 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL In the installation CD ROM menu click on Software of third parties in the next bookmark click on Uninstallation of HASP driver The uninstallation of the HASP driver starts once it is completed successfully a message appears This operation was completed successfully ATTENTION this operation may take several minutes Prior to the Program Initialisation Prior to starting communication of the A4000BDL program with the instrument it is necessary to connect the serial interface of the computer on which the program is running to the A4100 4200 instrument To connect them use the cable supplied with the instrument Insert one connector of the connection cable to any serial port of the computer for instance COM1 and connect the other connector to the A4100 4200 instrument at the point marked RS 232 CAUTION Without a correct connection between the computer and the instrument
10. the A4000BDL program will not run correctly The user software establishes serial communication with the analyser only if the main menu is present on the display of the instrument If the analyser is set in any other mode any attempt to establish communication will fail 5 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz ADASH Ltd A4000BDL Program Control Program Initialisation Launch the A4000BDL program by unpacking the Start menu and by clicking on A4000BDL The default location of this item is Start Programs Adash A4000BDL otherwise you find it by the specification you selected upon the program installation Description of the User Interface After launching the program the program user interface window appears A4101BDL x Version 1 05 6 ee Fig User interface of the A4000BDL program The user interface is made up three communication buttons a field for serial port selection and information fields for data viewing Starting Communication with the Instrument For communication between the instrument and the computer the following conditions must be respected The instrument and the computer are connected via a serial cable see chapter Prior to the Program Initialisation The connected instrument is ON The instrument is in the main menu CAUTI