Home
ODEnergy - OpenDomo Services
Contents
1. address 169 254 0 4 Configuration Gateway 192 168 1 1 Security Subnet mask 255 255 255 0 Primary DNS 8 8 8 8 Secondary DNS 208 67 222 222 MAC Address o0 04 A3 81 26 B7 Save Config Network configuration WIFI When the device has wifi support an additional option appears in the menu on the left named Wifi In this option you can adjust the settings as shown in the following image Overview Ethernet Enable WiFi WiFi S OPENDOMO Configuration Security Security WiFI Key Enable DHCP IP Address 169 254 0 4 Gateway 192 168 1 1 255 255 255 0 Subnet Mask Primary DNS 8 8 8 8 Secondary DNS 208 67 222 222 MAC Address 00 04 A3 81 26 B7 Save Config Current Transformer configuration ODEnergy supports different current transformers CT Normally each model is supplied with specific CT These CT are configured by clicking on Configuration You need to select the transformer being used in the CT selector If you select the transformer TA17L 05 you will be asked for a list of CT ratios This type of transformer is used to measure standard 5 transformers which can measure high currents In this case the CT TA17L 05 5 which is the measuring the circuit for more information see the installation guide In the following example a transformer type 1000A 5 so the ratio of transformation is 1000 5 Client server configuration ODEnergy can be a serv
2. memory that stores data for 15 minutes measurement frequency when the device fails to reach the Internet Only it works with Cloud ODE v2 protocol Single phase installation for ME and MEW models L1 Towards the N installation to be D measured Ethernet network Be E E WIFI Network The smart electrical meter O es Internet RESET h d MADE IN SPAIN RoHS x C L3 L2 L1 N O O OOO WIFI Network models when name is finished in W Three phase set up for TE and TEW models L1 N Ethernet network WIFI network L3 L2 Li N OO0O000 WIFI Network models when name is finished in W Circuit Circuit Circuit A B C N 5 current transformers setup IEC 60044 1 T ds th owards the L2 installation L3 to be measured N Ethernet network oo000 a E WIFI network Internet IN SPAIN RoHS x CE L3 12 11 N 1 loo0oood WIFI Network models when name is finished in W TE and TEW three phase set up L1 L Towards the installation L3 to be N measured Ethernet network OCOOCO eee A WIFI network Internet L3
3. L2 L1 N IDII lo o o o o WIFI Network models when name is finished in W 5 mts Max OOOOOO000 98 mm 53 mm L3 L2 1 N OOO000 OOO00000 MADEINsPAIN ROHS Compliant 86 mm DESCRIPTION OF OPERATION Using the reset button The device reset button has two functions e Shortpress 1 second device reset e Long push more than 5 seconds reset to factory defaults Status LEDs The color codes of the LEDs are LED status LED link e Flashing green Proper operation sending Solid green network connection data to the Internet e Off No connection to the network e Green red flashing Device connected to the network but cannot send data to the Internet e Flashing red The device cannot connect to the network e Solid green Device is ON but without network connection Device Access For configuration the device needs to be accessed To connect it to an ethernet network use a standard RJ45 cable To access simply use a web browser and enter the address http 169 254 0 4 Network configuration Ethernet To configure the network click on Ethernet Configuration data that can be modified is displayed For example in the following screenshot the IP address of the device has changed Ethernet Overview Ethernet Enable DHCP WiFi IP
4. S rvic cs BH Open Domo IP Electricity meter ODEnergy e Monitoring of global electricity consumption and sub metering e Rationalization of energy consumption e Datalogger e Remote monitoring of your facility via Internet e Overconsumption alarm generator e Direct integration with SCADA and BMS software e loT Internet of Things ODEnergy Electrical installation Cloud Opendomo Internet g Smartphone or computer Fig 1 Operating diagram Read all safety warnings All safety and operating instructions should be read before using the machine All warnings on the product and on the operating instructions should be strictly respected Failure to follow the warnings and instructions listed below can cause electric shock fire or serious injury including risk of death You must perform all operations for handling and assembly in the absence of voltage For any failure or doubt about the device operation the device must be disconnected You must install a protective circuit breaker to disconnect the equipment Be sure to connect the neutral voltage input in otherwise you can destroy the device Installation This equipment should not be installed by unqualified personnel otherwise there may be danger of death If you are not qualified do not install it Handling Unauthorized equipment handling or using it for the purpose intended is strictly prohibited Water and moisture This
5. er a client or both at once Server URL Address of the server where you are sending the data by ODE Cloud v2 protocol Port Port of ODE Cloud v2 server Cloud timer Frequency of sending data to the server ODE Cloud v2 Broadcast timer Frequency of sending data by UDP broadcast Broadcast Enable or disable Broadcast sending UDP data Server mode Enables or disables the sending of data to the ODE Cloud server Modbus TCP Enables or disables the Modbus TCP protocol For more information about communication protocols see the document of ODEnergy integrators or visit our Wiki http opendomo com wiki Overview Configuration Ethernet Current transformer WiFi CT Configuration CT ratio Security Server Warnmg Server URL ode 1 opendomo com Port 1730 Cloud timer 15min Broadcast timer 60sec v Broadcast Server Mode Enable Modbus TCP port 502 You can find more information about configuring the device at http docs opendomo com
6. irectives 2004 108 EC on Electromagnetic Compatibility 93 465 EC concerning the CE marking 2011 65 EU regarding the restriction of use of hazardous substances RoHS The device complies with the following standards CE ze Daniel Lerch Hostalot EN 61000 6 1 T EN 61000 6 3 measurement and power supply Current measurement Fig 2 Device elements TABLE OF FEATURES OF ALL MODELS Model System Connectivity ODEnergy ME Single phase Ethernet ODEnergy MEW Single phase Ethernet WIFI ODEnergy TE Single phase Three phase Ethernet ODEnergy TEW Single phase Three phase Ethernet WIFI Notes Ethernet WIFI versions only allow one of the two connections simultaneously EQUIPMENT FEATURES Measured variables Active power W reactive power VAr apparent power VA power factor voltage current frequency Energy Active energy generated and consumed Wh reactive energy in four quadrants varh Supply Voltage Line Neutral From 85 to 265 V AC frequency 47 to 80 Hz Device consumption lt 5 VA Relative error 1 Max power measured 6 MW Max energy measured 4294 GWh Ethernet connectivity 10Base T RJ45 connector WIFI Connectivity Compatible with 802 11 b g n networks Output Power 10dBm receiver sensitivity 91dBm supports WEP WPA PSK WPA 2 PSK Enclosure size 86x53x58 mm DIN rail format for 3 units Memory size 48 hours 1 The ODEnergy has an internal
7. product should not be installed near any source of water such as a faucet shower pool kitchen wet surface or alike without using protective measures such as the adequate sealing protection index according to applicable regulations Placement or installation of the appliance The appliance must be installed on a stable and appropiate DIN rail or an equivalent fixing Power supply This product should be operated only with a compatible power supply Please read the table of features Object and Liquid Entry Never access the device with any kind of object or pour any liquid as this may cause a short circuit and malfunction causing fire or electric shock In case of failure Do not attempt to service this product yourself opening or removing covers if you are nota qualified professional Temperature Do not exceed the storage temperature limits or operating temperature of the product The product should be situated away from any heat sources such as radiators stoves heaters or direct sun light Recycling This product should not be treated the same way as domestic waste instead you should take it to the nearest electronics recycling point For more information about recycling this product please contact your city waste service or the shop where you purchased the product DECLARATION OF CONFORMITY Declares under its own responsibility that the ODControl electronic product to which this declaration meets the requirements of the following d