1. SBARSKA User s Manual for Biometric Safe Read all instructions before using this safe WARNING New Safe is in either Pre registered mode or Factory Default mode ANY fingerprint can open the safe Only a successfully registered Fingerprint s can terminate Factory Default mode Register at least two different fingerprints and test a few times before closing the safe door Test with a non registered fingerprint If the safe opens the safe is still in Factory Default mode Avoid leaving safe door open and unattended it will allow unauthorized individuals to add their fingerprints and or reprogram the safe gaining full access to the safe and the contents Test the Emergency Keys and store them in a secure place NOT inside of the safe To maximize the security and performance of the safe test registered fingerprints every 6 months Initialization button cover must be restored after every use If user resets the safe to Factory Default mode ANY fingerprint can open the safe oO A Initialization Button B Battery Compartment C Bolts D Fingerprint Scanner E Indicator Lights F Wake Up Button o 9 gt Q i O BARSKA O Naa A DCTS Actual model may vary G Logo Plate and Emergency Key Access H Handle External Battery Pack batteries not included J External Battery Access GETTING STARTED 1 Remove Emergency Keys fr
2. warranty is limited to original purchaser and is not transferable This warranty applies only to products purchased in the United States Please email info barska com or call 1 888 666 6769 for Return Merchandise Number RMA before any returns The RMA number must appear on the outside of the shipping package Product must be packed carefully and sturdily in its original packaging to prevent damage in transit and returned freight pre paid to BARSKA OPTICS Repair Department 1721 Wright Avenue La Verne CA 91750 Please include all of the following when returning BARSKA products for service and or replacement 1 Please write your complete details Name Address Telephone E mail address RMA etc 2 Purchase receipt or Proof of Purchase Original Copy 3 A brief explanation of the defect 4 A Check Money Order of 60 00 to cover inspection shipping and handling Please allow 6 8 weeks for delivery BARSKA will examine and test returned product and repair or replace defective part s or units with new part s or a new unit if necessary within the warranty period Purchaser is required to remit 60 00 to BARSKA for return shipping and handling at time product is returned If repair is required after warranty period expiration purchaser will be charged for replacement parts and return shipping BARSKA Optics shall not be liable for any consequential incidental and or contingent damages whatsoever We will not pay shippin
3. e Up Button F Place a non registered finger on the Fingerprint Scanner D Turn Handle H clockwise the door should not open If the door opens with a non registered fingerprint registration was unsuccessful the safe is still in Factory Default mode Repeat steps under FINGERPRINT REGISTRATION and test multiple non registered fingerprints 2 Test a Registered fingerprint With door closed press and release Wake Up Button F Place a registered finger on the Fingerprint Scanner D Turn Handle H clockwise the door should open Registration was successful if it only opened with registered fingerprint s CLOSE OPEN SAFE DOOR CLOSE Close safe door turn Handle H counter clockwise to lock the safe OPEN Press and release Wake Up Button F Place a registered finger on Fingerprint Scanner D Turn Handle H clockwise to open the safe BEEP SOUND OPTIONS Beep OFF Press and HOLD the Initialization Button A 20 30 seconds until the Indicator Lights E flash green once RELEASE the Initialization Button Beep ON Press and HOLD the Initialization Button A 20 30 seconds until the Indicator Lights E flash green followed by 1 beep RELEASE the Initialization Button OPEN SAFE WITH EMERGENCY KEY 1 To expose the Emergency Key access remove Logo Plate G screws with provided tool 2 Insert Emergency Key into key access push and turn key counter clockwise and turn Handle H clockw
4. e holes for the anchors you are using Carefully press the anchor into the holes at this time Mount the safe by running screws from inside of the safe and securing to anchors ensure the safe is mounted securely Floor Mounting Use proper drill tools depending on the type of floor you are mounting the safe wood tile or concrete Measure the location of the pre set drill holes mark their exact position onto the floor Drill the appropriate size holes for the anchors you are using Carefully press the anchor into the holes at this time Mount the safe by running screws from inside of the safe and securing to anchors ensure the safe is mounted securely S BARSKA 1 YEAR LIMITED WARRANTY Biometric Safe BARSKA warrants this new safe to be free of original defects in material and or workmanship under normal use for a period of twelve 12 months from the date product is received by purchaser This warranty does not include damage caused by improper installation or maintenance Damage from misuse abuse accident such as dropping normal wear and tear fire flood or acts of nature Damage from service or repairs other than those performed by BARSKA Labor cost and shipping charges for the removal and replacement of defective parts beyond the initial twelve month warranty period All transportation and shipping charges Removing or altering the seal under any circumstances will automatically void the warranty This
5. g insurance or transportation charges from you to us or any import fees duties and or taxes This warranty supersedes all previous BARSKA Optics warranties 2012 BARSKA 1721 Wright Ave La Verne CA 91750 USA t 888 666 6769 f 909 445 8169 www barska com
6. ise to open the safe NOTE Store Emergency Keys in a secure place NOT inside of the safe OPEN SAFE WITH EXTERNAL BATTERY PACK Use this option when internal batteries are low 1 Insert 4 AA batteries into External Battery Pack I 2 Plug into External Battery Access J 10 12 See reverse side for more information BC266 3 Press and release Wake Up Button F Place a registered finger on Fingerprint Scanner D Turn Handle H clockwise to open the safe DELETE ALL STORED FINGERPRINTS RESET TO FACTORY DEFAULT MODE 1 Open safe remove Battery Compartment B cover and all 4 AA batteries 2 Press and release Wake Up Button F a few times until no beeps are heard 3 Press and HOLD the Initialization Button A Re insert batteries on the 4th battery you will hear 1 beep followed by 2 consecutive beeps indicating safe is in Factory Default mode 4 RELEASE Initialization Button A 5 Repeat steps 1 3 if a total of 3 beeps are not heard 6 Restore Battery Compartment B cover 7 All fingerprints stored in the safe have been deleted NOTE The safe is in Factory Default mode ANY fingerprint can open the safe 8 Continue with FINGERPRINT REGISTRATION and TEST NON REGISTERED FINGERPRINTS LOW BATTERY WARNING 1 When the door is closed and 3 repetitive beeps are heard and Indicator Lights E flash red it indicates the batteries are low 2 Replace batteries immediately Open safe remove Battery Compart
7. ment B cover and all 4 AA batteries Insert 4 new AA batteries and restore Battery Compartment B cover NOTE All registered fingerprints remain stored CARE AND MAINTENANCE To maximize the security and performance of the safe keep Fingerprint Scanner D clean use a dry cloth to remove any smudges or prints off the Fingerprint Scanner after each use Test registered fingerprints every 6 months Keep liquids away from the control panel Spills on the control panel will cause damage and possibly electric shock Secure safe in a proper area to prevent from falling and causing damage or injury DO NOT disassemble the product For all repairs contact BARSKA Customer Service DO NOT use chemicals or cleaning agents to clean the safe MOUNTING INSTRUCTIONS The safe may be mounted to a wall or BUUM Asees floor Be aware of the load bearing Failure to do so can result in personal injury and or damage to property Use appropriate tools when performing work and always use eye protection Wall Mounting Do not mount the safe without anchoring to the wall Find the studs in the wall at your desired location Most studs are 16 inches or 24 inches apart Check the wall for concealed wires or pipes Actual model may vary Measure the location of the pre set drill holes mark their exact position onto the wall ensuring that the studs or anything else behind will not interfere Drill the appropriate siz
8. om accessory package 2 To expose the Emergency Key access remove Logo Plate G screws with provided tool 3 Insert Emergency Key into key access push and turn counter clockwise 4 Turn Handle H clockwise to open the safe 5 Continue with INSTALL BATTERIES INSTALL BATTERIES 1 Remove Battery Compartment B cover 2 Insert 4 AA batteries and restore battery cover 3 Continue with FINGERPRITN REGISTRATION FINGERPRINT REGISTRATION IMPORTANT The safe is in either Pre registered mode or Factory Default mode test safe to determine factory settings below Pre registered mode Safe can NOT be opened with any fingerprint s Factory Default mode Safe can be opened with ANY fingerprint s 1 With the safe door open press and release Initialization Button A 2 Immediately place a finger on the Fingerprint Scanner D Hold finger still 1 beep will be heard recognizing the fingerprint followed by 2 consecutive beeps Remove finger Registration is complete Successful Registration Registration is successful when a total of 3 beeps are heard Unsuccessful Registration 2 short beeps will be heard repeat registration process again 3 To register another fingerprint repeat steps 1 2 4 Continue with TEST NON REGISTERED FINGERPRINTS TEST NON REGISTERED FINGERPRINTS 1 Test multiple Non Registered fingerprints Close safe door turn Handle H counter clockwise to lock the safe Press and release Wak