Home

User Manual - nu-beca

image

Contents

1. e Ear temperature indicator Non lens filter warning Temperature scanning in progress Temperature display Memory mode Record numbers Low bettery indicator Temperature unit Temperature indicator for memory mode Communication symbol Replacing the Battery The thermometer comes with two 1 5V AAA alkaline batteries Replace it when appears Please follow the steps to replace new batteries Step 1 Remove the battery cover Step 2 Place the new battery in the battery compartment and press it in until the battery is firmly secured Step 3 Reattach the battery cover NOTE 4 Although the thermometer works when appears we still recommend that you change the battery to obtain an accurate result 4 Remove the battery if stored for a long period of time 4 The battery should be kept out of reach of children If they are swallowed promptly see a doctor for help About Normal Body Temperature amp Fever Body temperature can vary from one individual person to next It also varies by location on the body and different time of the day Below shows the statistical normal ranges from different sites Please keep in mind that temperatures measured from different sites even at the same time should not be directly compared Fever indicates that the body temperature is higher than normal This symptom may be potentially caused by infection overdressing or immunization Some people
2. mometer 311 1261000 010 Version 1 0 April 2009 IMPORTANT SAFETY INSTRUCTIONS READ THIS BEFORE USING The following basic safety precautions should always be taken 1 Close supervision is necessary when the thermometer is used by on or near children handicapped persons or invalids 2 Use the thermometer only for the intended use described in this manual 3 Do not use the thermometer if it is not working properly or if it has suffered any damage 4 Do not use accessories which are not supplied or recommended by the manufacturer KEEP THESE INSTRUIONS TABLE OF CONTENT 6 Cautions and Warnings 07 Restrictions of Use oO 8 Introduction _ 0 Package Contents _ _ Thermometer Parts N LCD Screen _ 4 Replacing the Battery 6 About Normal Body Temperature amp Fever 17 20 2 23 26 26 27 28 29 30 Using the Device 17 Replacing Lens Filter 18 Taking Ear Thermometer Hints on Taking Ear Temperature Recalling the Memory Viewing Results on a Personal Computer Care amp Cleaning Fever Indicator Troubleshooting Specifications Symbol Information Warranty Cautions and Warnings 4 As with any thermometer proper technique is crucial to getting accurate temperature readings Please read this manual thoroughly and carefully before using 4 Always store the thermometer in a cool and dry place temperatures between 2
3. may not experience fever even when they are ill These include but are not limited to infants younger than 3 months old persons with compromised immune systems persons taking antibiotics steroids or antipyretics aspirin ibuprofen acetaminophen or persons with certain chronic illnesses Please consult your physician when you feel ill even if you do not have fever Table 1 Body Site Normal Temperature Range Oral 35 5 C 37 5 C 95 9 F 99 5 F Axillary 34 7 C 37 3 C 94 5 F 99 1 F underarm Rectal 36 6 C 38 0 C 97 9 F 100 4 F Ear 35 8 C 38 0 C 96 4 F 100 4 F 1 Chamberlain J M Terndrup T E New Light on Thermometer Readings Contemporary Pediatrics March 1994 Using the Device Replacing Lens Filter Step 1 Check the lens filter is clean and new Step 2 Attach new lens filter into the probe Now you can start to test your ear temperature A NOTE A If a lens filter is not attached on the probe LCD will show X until a new lens filter is firmly attached to the probe 4 The used lens filter should be removed after each measurement by a clean and new lens filter to ensure accuracy reading 4 For hygiene use attach a new lens filter each time and do not touch its tip Taking Ear Temperature Step 1 Make sure lens filter is firmly attached to the probe Step 2 Press and release the On Memory button to turn on the thermometer When
4. 0 C to 60 C relative humidity less than 95 Avoid direct sunlight 4 Avoid dropping the thermometer from a height or strongly hitting it with a hard object 4 Only use the lens filter for infrared nu beca RT 1261 ear thermometer 4 For proper hygiene do not share lens filter Damaged lens filter may result in error display 4 Do not disassemble the thermometer 4 Basic safety precautions should always be observed especially when the thermometer is used on or near children and disabled persons 4 This thermometer is not intended to be a substitution for consultation with your physician 4 Keep lens filters out of reach of children 4 Temperature of left and right ear may differ Always measure using same ear Restrictions of Use This thermometer is clinically proven to produce accurate temperature measurements However please be advised if you have the following situations A The accuracy cannot be ensured for a person who has deformity in the ear such that the thermometer probe can not be properly inserted into the ear canal 4 The accuracy cannot be ensured when blood or drainage is found in the ear canal 4 Take temperature from the other ear if ear drops or medications have been placed in an ear 4 For a person who wears ear plug or hearing aid remove the device and wait for 15 minutes before taking temperature NOTE Never try to clean inside the ears You may accidentally damage the eardrum or its surr
5. eca s office during normal business hours for warranty service We will then repair or replace defective parts or exchange the whole product as we select at no charge to the original owner After such repair replacement or exchange the product will be warranted from the date of purchase A This warranty is valid only if the Warranty Certificate and Warranty Registration Card are duly complete with date of purchase serial number and dealer s stamp and if the Warranty Registration Card is sent to local distributor office not later than 14 days from the date of purchase A This warranty is void if this product has been repaired or serviced by unauthorized person This warranty does not cover defects caused by misuse abuse accident tampering poor maintenance fire or any other acts beyond human control 4 Except as stated in the above paragraphs nu beca disclaims all other warranties implied or expressed including the warranties of merchantability of fitness for a particular purpose with respect to the use of this product nu beca shall not be liable for any direct consequential or incidental damages arising out of the use or inability to use product
6. ed backlight will last for 3 sec and turn off Troubleshooting The table below shows problems you may encounter All error messages below would be shown together with orange backlight Please follow what to do to resolve problems If the problem still exists please call your local dealer for help Message Err What it means Room temperature is below 10 C What to do Put the thermometer under operating temperature range of 10 C to 40 C Erre Room temperature is above 40 C You don t use lens filter while measuring ear temperature Put the thermometer under operating temperature range of 10 C to 40 C Please place probe cover into probe again Err4 Erri Err Err3 Problem with the thermometer Review the instructions and re start the measurement procedure If the above steps do not work Please contact the dealer Battery is low and 1 appears on LCD Please replace batteries as Soon as possible s IN is Appears when the batteries can t provide enough power for a test Temperature measurement falls outside the displayed temperature range ear temperature range from 32 C to 43 C Please replace new batteries Please follow this manual to take a reading again Specifications Model no RT 1261B Dimensions 160 5mm W x 45 9mm H x 32 5mm D Weight 98 33g include 2 x1 5V AAA batteries Batte
7. ory Step 2 Press the On Memory button to turn on the thermometer Step 3 Press the On Memory button for 3 o seconds to enter memory mode Each time you press the On Memory l LI I button a result will be displayed in 4C the order of dates latest result shown als first together with M and number from 1 to 10 When the memory is full the oldest result is deleted as the new one added When the last record is displayed in the LCD press On Memory button again to return the first record Step 4 Exit the memory Press the Scan button and LCD will show latest results with flashing ma Then press On Memory button again and LCD will show OFF to exit memory Care amp Cleaning 4 f you would like to clean the probe lens wipe it gently with an 70 alcohol swab or soft cloth moistened with 70 alcohol Do not attach a new lens filter within 30 minutes 4 The probe is not waterproof Please wipe with a clean cloth which is dry or damped with 70 alcohol 4 The body of the thermometer is not water resistant Never put the thermometer under a running tap or submerge it into water Use a soft and dry cloth to clean it Do not use abrasive cleaners 4 Store the thermometer in a cool and dry location Free from dust and away from direct sunlight Fever Indicator When the measurement is equal or over 38 0 C red backlight is shown together with the result The r
8. ounding tissues Remove excess earwax only when you can reach it with a clean cloth Consult a physician if you suspect the presence of excess earwax Introduction Thank you for choosing nu beca RT 1261 ear thermometer This innovative medical device relies on on advanced infrared IR technology to measure temperature instantly nu beca RT 1261 ear thermometer is an elegantly designed infrared thermometer meant for your family Intended use nu beca RT 1261 ear thermometer is intended for the intermittent measurement and monitoring of human body temperature from ear canal The device is intended for use by people of all ages in the home How does it work The thermometer measures the infrared heat generated by the eardrum and its surrounding tissue The thermometer then converts it into a temperature value shown on LCD NOTE The thermometer does not emit any infrared signal Package Contents nu beca RT 1261 Ear Thermometer User s Manual YARRA NT y Warranty Card Two 1 5V AAA Batteries Lens Filter E s Storage Case Thermometer Parts Lens filter Lens filter ejection button On Memory button Sticker Battery cover Data port Probe lens Probe Lens filter detector o O 8 8 00 8 Scan button LCD Screen o 60006 ui C 5 FX vor o III MELLE o O
9. ready the thermometer displays the last measurement Step 3 Gently fit the probe into the ear canal Step 4 Press and release the Scan button Do not remove the thermometer until it beeps Step 5 Read the result 5 is shown together with a temperature value Step 6 Discard used lens filter into trash by pressing lens filter ejection button NOTE Turn off the thermometer by pressing On Memory button twice It will automatically turn off if left idle for 3 minutes Hints on Taking Ear Temperture 1 As with other of thermometer you may observe slight variations in consecutive measurements It is recommended that you take 3 temperature readings and use the highest one for the following situations 4 Infants younger than 3 months old 4 Children younger than 3 years old and who have a compromised immune system and the presence absence of fever is critical 4 When you are learning to use the thermometer 2 Do not take a reading while eating and or talking Wait 30 minutes after any of the following situations before taking a measurement 4 When you have your ear covered 4 After exercising swimming or taking a bath When expose to extreme temperature 3 To take accurate readings the ear must be free from excess earwax build up Recalling the Memory Your thermometer stores 10 recent readings in the memory Step 1 Be sure the thermometer is OFF before recalling this mem
10. ry 2 x 1 5V AAA alkaline batteries External output Displayed temperature range UART USB amp RS232 ZigBee Bluetooth 32 C to 43 C 89 6 F to 109 4 F Display resolution 0 1 C Accuracy Meet the accuracy requirement specified in ASTM E1965 98 4 0 2 C 0 4F for the range of 36 0 C to 39 0 C 96 8 F to 102 2 F A 0 3 C 0 5 F from 34 0 C to 35 9 C 93 2 F to 96 6 F and from 39 1 C to 42 2 C 102 4 F to 108 0F Temperature unit 1 Operating temperature range Operating humidity Storage temperature range 10 C to 40 C 50 F to 104 F 95 RH or less 20 C to 60 C 4 F to 140F Storage humidity 95 RH or less Memory capacity 10 measurements The specifications may be changed without prior notice Symbol Information Referent Consult instructions for use Keep away from sunlight Keep dry Temperature limitation Date of manufacture Manufacturer Serial number Caution consult accompanying documents Authorized representative in the European Community CE mark Type BF equipment Do not use if package is damaged Warranty 4 nubeca warrants this product to be free of defects in workmanship and materials for a period on ONE year from the date of purchase 4 During the warranty period if this product is found to be defective you may bring it together with the purchase receipt and Warranty Certificate on a carry in basis to nub