Home

Universal Cart Operatory

image

Contents

1. Chemical Disinfection If chemical disinfection is the disinfection method of choice it is imperative that a mild soap and warm water be used once per day to mitigate the residual effects of chemical disinfection solutions When using chemical disinfection solutions always pay strict attention to use detail including appropriate measurements when using concentrated disinfection solutions Disinfection solutions used in the recommended strength can be relatively harmless to surface of dental equipment Unacceptable Disinfectants SC Conditional Accepted Disinfectants Disinfectants with the following Disinfectants with the following compositions will harm the surface compositions have been found to be finishes of dental equipment and the LEAST HARMFUL to equipment are not recommended Use of surfaces by our test methods these products will void your warranty Chemical Composition Chemical Composition Strong Phenols lodophors Phenol Alcohol Combinations Mild Phenols Sodium Hypochlorite Household Bleach Glutaraldehyde Phenol Sprays Alcohol Alcohol Based Wipes Synergized Super Quat Household Cleaners Phenol Water Sprays Damage and discoloration of the surface finishes caused by disinfectants are NOT covered by warranties lodophor based disinfectants will cause yellow staining on many surfaces Regular washing with soap and water will minimize this staining lodophor neutralizers such as Promedyne are also available WARR
2. wat sto NOTE Verify if Self Contained 1 Water System B is being used pi 3 as Public Wa j 5 b z 9 Critical Notes 1 Werif Dental will Line Size installed ENTRANCE IE lt a DT Ho Me tel of Wood Ttud Water Requirements os elivery Systems with Self Containted Water Systems not require Water in J Box 2 Verify Vacuum Model as May Change 3 Uniform Plumbing Code requires any Dental Delivery System to to the Public Water i deli an independent Backflow Devic Verify with the Loca Building and Safety nished Floor DENTAL JUNCTION BOX CONNECTIONS Local building codes and regulations may require licensed plumbers and electricians to install utilities Make sure all plumbing conforms to prevailing local building codes and regulations Air Supply from Compressor 1 2 pipe NPT protruding 1 from floor or wall with 1 2 x 3 8 compressor fitting angle stop required Supplied by contractor Air pressure from dental air compressor operating range 80 to 100 PSI Air from dental air compressor must be clean and dry Air plumbing lines must be flushed clean before making final dental junction box connects Water Source 1 2 pipe NPT protruding 1 from floor or wall with 1 2 x 3 8 compressor fitting angle stop required Supplied by contractor Water Pressure Operating Range 25 to 35 PSI Water plumbing lines must be flushed clean before making final dental junction box connects
3. ANTIES Dansereau has the most comprehensive product warranty programs available to the dentist today We offer a 10 Year Warranty on our Dental Chairs and Delivery Systems with complete features listed below 3 Years 10096 4 10 Years Prorated Annually Delivery System Internal Tubing against leaks Master Valve Regulators Handpiece Control Blocks Not Gaskets Light Posts Automatic Handpiece Holders Delivery Sys tem Water and Air Flow Control Valves Stool Cylinders Manual Chair Switches De livery System Flex Arm Delivery System Telescoping Arm Cuspidor Frame 1 Year 100 Diamond Dental Light Chair Foot Control Stool Ring Stool Seat Stool Casters Circuit Board and Prepositioning Switches 6 Months 100 Base and Unit Cover parts 3 way syringes Delivery System Foot Control and Fiber Optics systems 30 Days 100 Dental Light Bulbs Fiber Optic Light Bulbs X ray View Box Light Bulbs Broken or User Damaged Items are Not Covered under Warranty Minimum Maintenance is required in order to guarantee full use of warranties All dental delivery systems require clean dry air to allow the proper lifespan to the micro valves within the dental delivery system If your air compressor does not have an adequate drying and filtration system the warranties of the micro valves on off toggle valves relays regulators master valves foot controls 3 ways syringes and automatic blocks may be void GUARANTEE Dansereau will gu
4. America s Dental Equipment Company UNIVERSAL CART SYSTEM Owners uide 2019 INFINITY DANSEREAU s aan N A Dansereau 800 423 5657 WWW DHPDENTAL COM Rev 2 15 DANSEREAU HEALTH PRODUCTS INC AMERICA S DENTAL EQUIPMENT COMPANY Dansereau Health Products Inc has been manufacturing dental equipment for over 40 years We have compiled a significant amount of data and information regarding the manu facturing use and maintenance of dental equipment Information contained in this manual will assist you in use and maintenance of your Dansereau equipment We offer the most comprehensive 10 year warranty on USA manufactured dental equipment today Our customer service department is the most progressive within the dental industry with an ever growing series of support documents and video available thru E mail and the Internet They are easily accessible and completely descriptive for the dentist staff or any technician to use in the long term support of Dansereau Health Products Inc SUPPORT ACCESS Dansereau Health Products Inc 1581 Commerce Street Corona CA 92879 Toll Free 800 423 5657 951 549 1400 Fax 951 549 1411 Website WWW DHPDENTAL COM TESTING LABORATORIES ETL Testing Lab Report 530937 Medical and Dental Equipment Category 6 UL 544 2nd Ed CAN CSA Testing Laboratories Report 531003 Canadian Standard for Medical Electrical Equip No 601 1 M90 US Food and Drug Adminis
5. Electrical 1 2 conduit and box with duplex outlet supplied by contractor Wire electrical box as per code Horizontally no higher than 4 from finished floor Central Vacuum Vacuum system plumbing specifications to be supplied by central vacuum sys tem supplier Terminate in the dental junction box according to dental junction schematics Confirm line sizes with central vacuum system supplier UNIVERSAL CART ASSEMBLY GUIDE 4 Install Amalgam Trap on Open Shipping Box Do rear of Unit Head with Screws not Use a Razor Knife 1 Install Vacuum Hose on Amalgam Cannister Remove the Universal Cart from 9 the Shipping Box It will be fully assembled d TI J WAY 5 Insert Master Valve Nipple into the Angle Stop and Tighten Nut Slide on the Vacuum Tubing to the Select the most comfortable height Vacuum Fitting installed within the 3 gt for the Unit Head and Hand Tighten Dental Junction Box the Gray Knob to hold the position i i Ning a F J Adjustment Knob Universal Cart is Assembled and installed OPERATING INSTRUCTIONS Handpiece Connections 3 Way Syringe High Speed w Water High Speed w Water Low Speed No Water Saliva Ejector Valve HVE Valve Handpiece Controls 1 High Speed Air Adjustment 2 High Speed Air Adjustment 3 Low Speed Air Adjustment Delivery System Controls Master On Off Toggle 2 Water Flow Adjustment 3 Water On Off Toggle Operation Specificatio
6. UTION gt CAUTION iNOLINA LLY Ay AC Alternating Current See Definitions of Symbols section Protective earth Ground IPxy Protected against splashing water He FEE NA BEN Rien eine ER erat mie A ia WARNING V Attention Consult accompanying documents THIS DEVICE SHOULD ONLY BE CONNECTED TO HOSPITAL GRADE OUTLETS FAILURE TO DO SO MAY RESULT IN i O OFF N ELECTRICAL SHOCK DUE TO IMPROPER GROUNDING i 1 N f ATTENTION ON a CET APPAREIL DOIT ETRE BRANCHE A UNE PRISE DE AKA TERRE ADEQUATE lt 17 f ADVERTENCIA o Type B equipment R d ESTE DISPOSITIVO DESE CONECTARSE UNICAMENTE A Protected against electrical shock TOMACORRIENTES DE GRADO HOSPITALARIO 5 NO BE HACE i AS PUEDE PRODUCIRSE UN CHOQUE ELECTRICO A CAUSA l DE UNA PUESTA A TIERRA INADECUADA 5 Dangerous voltage 70 22680 Rev 5 111 DENTAL UNIT STANDARDS AND MAINTENANCE HANDPIECE COMPATIBILITY This delivery system is designed to be compatible with air driven pneumatic handpieces that conform to ISO 13294 The air driven pneumatic handpieces tubing and connectors are available in either 4 hold Midwest or 3 hole Borden tubing other configurations are available under special order The end user dentist will have specified the preferred type of connection during ordering It is the responsibility of the end user dentist to procure appropriate handpieces to work with the handpiece connections specified at time of order confirm
7. arantee against defects in material and workmanship Defec tive parts will be repaired or replaced no claim for labor or consequential dam ages will be allowed All replacement parts claimed defective will be filled in the usual manner such invoice being subject to adjustment after the alleged defective material has been returned and inspect by the manufacturer The warranty does not cover damage resulting from improper installation maintenance accident or misuse
8. ation Certain countries may have particular regulations regarding which handpieces are acceptable for use e g countries in the European Union require handpieces which meet the requirements of the medical devices Directive 93 42 EEC NOTE Regarding International Electrical Specification Dansereau does not supply provisions for international power requirements with the dental unit SUGGESTED TOOLS Allen Wrench Set 9 16 Socket Wrench 7 16 Open End Wrench Chanell Locks 1 2 Socket Wrench REPLACEMENT PARTS The following represents a condensed list of maintenance parts that may be used during the normal lifespan of the dental unit Contact Dansereau direct for a complete list of additional parts 800 423 5657 Master Shut Off Valve Filter DA1238B Saliva Ejector Tip QTY 5 DA1284 2 NI Amalgam Trap Solids Filter QTY 10 DA1234 Amalgam Trap Mounting Bracket DA1231 DENTAL CART SPECS 8 J BOX SCHEMATICS Universal Cart Specs 21 x 19 Top Height Adjustable U Cart SS 19 35 to 27 EE ii Rotating Unit Head move r Ti from Right to Left Side of KAWI a Cart dL Rotating Assistants Package 32 High mover from Right to Left Low 22 Side of Cart Complete Junction Box Not Shown wi Laminated Worksurface Ww we 21 x 18 can be altered in ee al Se by reguest m 1 Wood Frame f 1 Wood Frame Drywan SNAHE ag Drywall or Wosa Stud ETE
9. er pressure on the junction box gauges The gauges must read e Air 75 to 80 psi e Water 35 to 40 psi Turn the air regulator knob clockwise to increase the pressure and counterclockwise to decrease For an accurate reading from the gauge bleed off the air pressure by using the air syringe button on the 3 way syringe Adjust the air pressure regulator knob in half turn steps CAUTION Pressure adjustments should be completed in a series of short steps Avoid running handpieces for extended periods longer than is required to check pressure Extended running with no load can damage the handpiece No handpiece should ever be run without a bur in the chuck CAUTION When not in use the master switch should be left in the OFF position The master switch is an important STERILIZATION TECHNIQUES Infection control in the dental facility continues to be a high priority for all staff working within the dental office OSHA the ADA and CDC are all involved in this complex is sue Dansereau will not attempt to specify the required intervals for disinfection nor can they recommend the overall best surface disinfectant You can refer to the appro priate organizations for more information on disinfecting your dental equipment Techniques Barrier Technique Dansereau does advocate the barrier technique whenever possible The use of dis posable barrier s with changes between patients will ensure the finish and appear ance will be preserved
10. lass 2A product under rule 11 of Annex IX of the MDD 93 42 EEC accordingly the provisions of Annex Il apply NOTE Regarding International Electrical Specification Dansereau does not supply provi sions for international power requirements This will be configured by the equipment dealer in the country of destination SAFETY AND IDENTIFICATION MARKINGS CAUTION Failure to carefully follow the Safety Labels described procedure may result in damage to HE RISK OF EXPLOSION IF USED IN THE 2 the equipment PRESENCE OF FLAMMABLE ANESTHETICS WARNING Failure to carefully follow the RISQUE D EXPLOSION FN PRESENCE DE e A PRODUITS ANESIHETIOUES INFL AMMASI FS described procedure may result in damage to sn RIESGO DE EXPLOSION Si SE UTILIZA EN the equipment and the operator PRESENCIA DE ANESTESICOS INFLAMABLES ELECTRIC SHOCK HAZARD DO NOT REMOVE COVER REFER SERVICING TO QUALIFIED SERVICE PERSONNEL 5 m z 4 rm mm O 3 A DANGER Fi Risk of electrical shock present Make sure N power is disconnected before attempting this procedure RISQUE DELECTROCUTION NE PAS OUVRIR LE GOUVERGLE FAIRE APPEL UN TECHNICIEN QUALIFI N LA RIESGO DE CHOQUE ELECTRICO NO QUITE LA CUBIERTA CONTRATE EL SERVICIO CON PERSONAL DE SERVICIO CALIFICADO Os ROM FEV IEC Symbols The following symbols conform to IEC labeling standards and may be located throughout the product CA
11. ns 1 3 way syringe offers two buttons to activate and air and water flow both buttons can be activated and creating an air and water mist 2 High speed handpiece connections are threaded connection for attachment of a high speed dental handpieces Water and air are supplied 3 Low speed handpiece connection is a threaded connection for attachment of a slow speed dental handpiece Air is only supplied 4 High and low speed adjustments increase or decrease air flow to dental hand pieces 5 Master on off toggle extremely important item that turns off dental delivery system at the conclusion of the work day Must be on to use dental delivery system 6 Water flow adjustment increases or decreases water flow to handpieces 7 Water on off toggle turns on or off water flow to handpieces 8 Air lock flex arm toggle activated a brake in the flex arm mechanism to allow the flex arm to hold a stable vertical position with items on the unit tray if required START UP AND DISINFECTING UNITS Dental Unit Start Up Check to see that the master on off toggle in in the OFF position Turn on the master air and water valves located in the dental junction box Make visual inspection for air or water leaks Turn the master on off toggle to the ON position and make a complete inspection for the leaks in the following applicable areas e Junction Box e Utility Center e Control Head e Internal plumbing of the control head Check air and wat
12. tration Medical Device Registry 202716 DENTAL UNIT SPECIFICATIONS No Electrical Components are installed in the Dental Unit Dental Unit Weight 97Ibs IEC Medical Device Classification Classification 2A Type B Operation Mode No Electric in Dental Unit Splash Protection IPX4 Maximum Torque of Accessory Items 601lbs ft 81 N m DANSEREAU HEALTH PRODUCTS INC AMERICA S DENTAL EQUIPMENT COMPANY TECHNICAL DESCRIPTION The dental delivery system is a combination of dental equipment components used to carry position and control the devices used in the practice of dentistry Delivery systems provide handpiece connections that deliver air water and vacuum to the patient Delivery systems generally have several components all are needed to provide dentistry including a control head cuspidor system assistants utilities and a junction box Delivery systems can be mounted to the wall cabinet dental chair or a mobile cart Air water vacuum drain and generally enter the system through the junction box Shut off valves and pressure regulators are located in the junction box Tubing delivers air water and vacuum to the control head for operating pneumatic items The control head contains adjustment knobs for controlling handpiece pressure and the amount of coolant air and water The dentist controls the rate and flow through the pres sure applied to the foot control or syringe buttons The dental chair is classified as a C