Home
2N BRI Lite - Keil Telecom
Contents
1. BRI 1 2B D wpe Fig 11 Basic ISDN GSM Gateway Wiring Diagram Choose the specific wiring as shown in Section 4 2 9 Status Indicators There is a panel with five LEDs on the gateway upper cover for a quick GSM gateway status detection see Fig 12 The Power LED signals that the gateway as a whole is in operation The BRI 7 and BRI 2 LEDs indicate the status of both the B channels of the basic ISDN extension and the GSM 1 and GSM 2 LEDs indicate the status of the respective GSM modules cui SO cH2 O BRI1 BO BRI2 O Power O Fig 12 Signalling LEDs Basic diagnostic tests and gateway initialisation are performed automatically whenever the gateway is connected to supply voltage Each test step is signalled by a specific colour combination of the LEDs If a test step fails the indicator combination related to the failed test remains lighted This provides a convenient troubleshooting tool to the technical support personnel 16 Power Indicator The Power LED signals whether the BRI GSM gateway is supplied or not BRI Indicators Power Indicator green Power LED colour status No light The system is not working Blown fuse Continuous light The system is working Tab 1 Survey of Power Indicator Statuses The BRI 1 and BRI 2 LEDs signal the statuses of your ISDN extension B channels each being assigned to two lines of the opposite direction TE NT BRI I
2. Messages to ISDN interface outgoing calls to GSM gt Delay before send CONNECT s 0 Dont send ALERTING message Send ALERTING message after dial from GSM Delay before send ALERTING s Time limitation of SIM card From 00 00 To 24 00 jv Enable on weekends C Use whole weekend Use the above set time T Use 2nd interval Fig 39 Editing Window of GSM outgoing parameters The 2N BRI Enterprise allows you to setup both GSM modules for call to the GSM network independently You can select different settings for each of them with respect to establishing connections count of called minutes and sent 72 messages within a period To set the default parameters use Default For advanced settings use Advanced button The meanings of the card items are as follows 8 10 1 8 10 2 8 10 3 Same setting as GSM module 1 this checkbox sets the same parameters for GSM module 2 as on the GSM module 1 fold GSM calls statistics Max number of called minutes defines the maximum number of minutes called within a moth through the given SIM card This parameter is ignored if 0 is selected Minute parameter is used for setting up whether statistics are counted in minutes or in number of calls SMS messages number defines the maximum possible number of SMS messages sent within a month from the given SIM card This parameter is ignored if 0 is selected Day of delet
3. 8 7 1 ISDN BRI port settings e Interface adjusts the BRI interface of the gateway This port operates as a network termination with respect to the other ISDN terminals on the given port In addition to monitoring and diagnostic functions the GSM gateway provides access to the D channel and power supply to the other ISDN terminals connected in this mode e Port setting Interface NT simulate PSTN NT TE connection like ISDN terminal Point to point when the gateway is connected to one device only i e TE port of your PBX It is possible to choose fixed TEI Terminal Endpoint Identifier assignment from range 0 to 63 0 is mostly used for the point to point configuration or dynamic TEI assignment TEI 64 in case of point to point configuration For dynamic TEI assignment TEI is assigned from range 64 to 126 TEI 127 is used for broadcast messages Point to multipoint if the gateway is connected to more terminals the dynamic TEI assignment must be selected DISA dial tone Activated DISA DTMF dial tone for second dial used for connection on PBX extension line 8 7 2 Tone signalling for calls to ISDN Dial tone with this function enabled the GSM gateway sends the dialtone to the NT port if the SETUP message does not include the calling subscriber s number Ring tone selection of control ring tones which are to be played to the caller from the ISDN network 8 7 3 Generating busy tone
4. Route calls to ISDN BRI 1 port Use LCR table then reject a call Use LCR table then route to BRI 2 port GSM channels 1 and 2 Reject all incoming calls Route incoming calls to ISDN BRI 2 port Incoming calls will be routed to GSM or opposite ISDN BRI port according to LCR table If there will no be valid line call will be rejected All incoming calls from this interface will be routed directly to the opposite ISDN BRI port This settings ignores LCR table Incoming calls will be processed according to GSM incoming calls settings and routed to ISDN 1 port if vou set so Major route settings for GSM and ISDN BRI ports e GSM parameters General 59 2N BRI Enterprise GSM outgoing calls GSM incoming calls Prefixes LCR table Autorouting Table 8 2 2N BRI Enterprise Gateway Communication Establishing Select the gateway to be configured from the list of gateways available in the Main menu in the Gateway list tag Now select the type of GSM gateway connection in Setting Communication settings refer to Subs 1 3 4 in the Main menu Having selected the communication type click on Connect gateway to establish connection between the PC and GSM gateway With the GSM gateway communication type selected connect the GSM gateway by clicking on Connect gateway A in the Button bar 8 3 Firmware Version Identification If you have connected the GSM gateway for the first time pleas
5. Communication settings X Communication type Communication type Serial communication v Serial communication settings Serial port COM4 Communication LOG j Save communication LOG to a file j Append LOG file OK Fig 33 Communication Setting Window Types of communication Serial communication used for GSM gateway configuration from your PC using a USB cable communicating via a virtual COM port at the rate of 921 600 bps which is selected in the Serial communication setting item The serial communication mode is suitable for the initial setup of the gateway The configuration program offers available COM ports Modem used for GSM gateway configuration via GSM CSD modem Be sure to set the correct gateway dialled number and activates licence before configuring LAN used for GSM gateway configuration via Ethernet Telnet protocol GSM CSD modem Be sure to set the correct gateway IP address IP port and access username password LOG communication You can set whether and how the PC GSM gateway communication should be saved into a file Having selected the type of communication you select the transmission rate by clicking on Find out speed Having found the transmission rate value you establish connection between the PC and GSM gateway by pressing Connect The Disconnect key cancels this connection To confirm changes press OK e Application language sets the language used
6. e If the gateway does not receive the minimum required count of digits and no other digit comes from the GSM network within the timeout defined in DTMF dialling delay the call is rerouted to the operator as the case is when the extension number dialled by the calling party is unknown e If the call rerouting to the operator is inactive the incoming call is rejected 5 6 DISA Message Recording If the DISA function is enabled and a welcome message recorded this voice message is replayed to every incoming call whose number is not included in the AutoCLIP routing table After the message is replayed the gateway waits for the first DTMF digit for a timeout defined in the GSM incoming calls Timeout while inputing DTMF digits s table Having received the count of digits defined in GSM incoming calls Minimum digits in DTMF the gateway activates the PBX or telephone connection with the number received by the DTMF via the ISDN port For more details on the gateway configuration refer to Section 8 To establish connection with a lower count of digits than defined in GSM incoming calls Maximum digits in DTMF terminate the dialling with the character When the DISA does not receive the pre programmed count of digits or the 7 character the connection is not established Therefore enable the operator service while activating the DISA function in the router mode only no is needed in the PBX mode There are three ways to
7. 1 IDLE Activation rest status necessary for layers 2 and 3 2 DISC Deactivation 96 GSM Layer Statuses GSM Layer 2 Status Messages ID Name Description Followed by O INIT GSM module initialisation start PINREQ 1 SIMO Module switch to internal SIM card INIT 2 PINREQ Module PIN request PINSET 3 PINSET PIN value sending to module INFO 4 BLOCK Module blocked temporarily or permanently see Layer 2 information INIT 5 SETUP Module configuration running IDLE 6 SLEEP Module sleep running transition to BLOCK status BLOCK 7 NWAIT Awaiting GSM log in SETUP 8 IDLE Rest status can start receive call execute AT amp G command CALL CMD 9 CALL Call running call establishing connected call call end IDLE 10 CMD Communicating with module upon AT amp G command IDLE 13 INFO Information loading from module and SIM card NWAIT GSM Layer BLOCK Status Messages ID Name Description 41 block Blocked by AT amp G command terminated by module board or system reset 42 Netw reg GSM log in refused not activated SIM next attempt in 5 60 minutes 43 Clir err CLIR activation request refused next attempt in 2 10 minutes 44 Mod err Defective or not connected GSM module next attempt in 2 minutes 45 Pin err Wrong PIN permanently in BLOCK status 46 Sim err Defective or not inserted SIM card next attempt in 2 minutes 47 Log out Temporarily logged out according to parameter X00 48 Pu
8. General Number of digits dialed from ISDN Min numbers from ISDN Max numbers from ISDN SIM cards PIN code number gt 4 numbers I 234 Cyclic v Wait for next digit s 3 ta GSM module selection Voice parameters of W avecom modules TUN parameters of Siemens GSM modules SEG oto OF M Transmission volume Transmission volume lA cR 1G ei Az 6 42 03244 46 Reception volume Reception volume 5 25 0 25 5 6 4 2 O 2 4 6 Enable Siemens s connection tone Settings of Sierra Wireless modules Transmission volume J i 5 25 0 425 5 Reception volume W RS i9 25 URS UH GSM and 3G 3G then GSM l Type of used networks Searching priority Send AoC for calls BRI GSM Signalling tone for calls to GSM Dial tone European v Ring tone European v Relax delay s 2 DTMF Delay 1 1005 1 SIM card number IMSI Don t send CLIP for incomming calls GSM BRI SiM card v Received SMS will be saved to Tranfer to cause Add Remove Remove all Generate busy tone to GSM s jo 4 0 of Fig 38 Basic GSM Parameter Editing Window This section contains basic settings for routing calls to the external GSM ports of the gateway The Default button sets the default values The Advanced button offers possibility of advanced GSM general parameters configuratio
9. Separating char Add new record only for unconnected call Delete record for connected answer CLIP replace by expression Looping of voice mess min 0 1 x 0 Prefix before DISA preselection Fig 40 Incoming GSM Group Editing Window The 2N BRI Enterprise allows you to setup both GSM modules for call from the GSM network independently You can select different settings for each of them with respect to establishing incoming calls To set the default parameters use Default For advanced settings use Advanced button The meanings of the card items are as follows 76 e Same setting as GSM module 1 this checkbox sets the same parameters for GSM module 2 as on the GSM module 1 fold 8 11 1 Mode Set the way the GSM gateway shall process incoming calls from the GSM network Reject incoming calls all incoming calls from the GSM network are rejected automatically Ignore incoming calls all incoming calls from the GSM network are ignored automatically The calling subscriber hears the ringing tone Receive incoming calls voice message incoming calls from the GSM network are received and if defined so the DTMF with a voice message is enabled for the incoming call Receive incoming calls dialtone incoming GSM calls are received incoming calls from the GSM network are received and if defined so the DTMF with a simulated dialtone is enabled for the incoming call CallBack after ring Re
10. e Antenna connection connect an internal antenna or an external antenna cable into the SMA antenna connector Place the external antenna on a place with a good GSM UMTS signal refer to Subs 2 5 e Gateway power supply the delivery includes a mains adapter Plug in the adapter connector into the gateway and the power adapter into a wall socket The gateway turns on immediately see Subs 0 2N BRI Enterprise SIM card insertion SIM cards are inserted in holders on the gateway top The SIM card holder is of the push pull type which means that all you have to do is insert a SIM card and press the holder gently until it snaps into position see Subs 2 7 Secure the SIM card with a latch to avoid incidental removal CAUTION If you use SIM cards with active PIN protection first set an identical PIN code for all SIM cards used in the GSM gateway save it into the GSM gateway configuration and only then insert the SIM cards in the GSM gateway PC connection the gateway parameters are normally set using the configuration software available on the CD included in the delivery To interconnect your PC with the GSM ISDN gateway use the USB cable included in the delivery Configuration program installation run the installation file from the installation CD on a PC connected to the gateway and install the configuration software refer to Subs 7 1 Configuration program run the configuration program installed and
11. 64 To BRI for X sec in case of activation this parameters busy tone will be played for X seconds after call to GSM termination 8 7 4 Progress elements The purpose of progress elements is to describe the behaviour of terminals involved in a connection You can set here which progress elements should be sent in the SETUP ACKNOWLEDGE CALL PROCEEDING PROGRESS and ALERTING messages Please keep the configuration settings of your PBX or router to avoid false evaluation of the messages transmitted by your GSM gateway and thus connection establishing errors The decadic numbers assigned to progress elements are included in Chyba Nenalezen zdroj odkaz Number Meaning 1 The connection is not of the end to end ISDN type further progress messages will be sent in the voice band The destination address is not of the ISDN type The connection initiator address is not of the ISDN type The connection returns to the ISDN Oj BOND The communication of the interconnected systems led to a change of the telecommunication service for the end to end ISDN mode only Delay due to call interface failure Tab 5 ISDN Cause Meanings 8 7 5 Release causes to ISDN Cause messages are sent to those terminals whose connection request has been rejected They contain causes of rejection For precise definitions of the messages refer to the ITU T Q 931 recommendation You can set the type of the message to b
12. SECTION 4 BRI GSM Gateway Connection Options This section deals with the connection options of the 2N BRI Enterprise to the ISDN Basic Rate extension This section includes e Connection of ISDN TE to 23 2N BRI Enterprise e 2N BRI Enterprise Point to Point Connection e Chyba Nenalezen zdroj odkaz e 2N BRI Enterprise as Pass Through Router 24 4 1 Connection of ISDN TE to 2N BRI Enterprise The connection in Fig 16 provides communication via a GSM gateway without PSTN connection The ISDN telephone set is connected to the NT port of the GSM gateway while a mains adapter simulating power supply from the public network is connected to the TE port The adapter is available under the part No 5020001 ISDN telefon ISDN phone Sitovy adapter ISDN power adapter Fig 16 ISDN Telephone Gateway Connection with Power Supply Simulation 25 2N BRI Enterprise 4 2 2N BRI Enterprise Point to Point Connection This type of connection is especially suitable for direct calls from an ISDN branch network to a GSM network Fig 17 ISDN BRI GSM Point to Point Connection as ISDN NT 26 Fig 18 ISDN BRI GSM Point to Point Connection as ISDN NT with Public ISDN Synchronisation Fig 19 Multiple ISDN BRI GSM Gateway Connection 27 2N BRI Enterprise 4 3 2N BRI Enterprise as Pass Through Router Fig 20 shows how to save one BRI port to the PBX where the GSM gateway
13. e Tracing for analysis of the GSM gateway behaviour on each RM OSI model layer Time stamps may be assigned to the records for better orientation in listings Set details of tracing 1 Select tracing type T State of layers 3 and 5 Select tracing GSM ISDN Messages JV Timestamp for each message SMS Bus packets CPU lt gt AUX Layers 2 3 4 State of layer 2 C Layers 3 4 jv LCR routing and Sim select C Layer 4 Start Default Clear RI Lite program 2N H Tracing txt E V Save to file Fig 31 Tracing Window 51 2N BRI Enterprise e Terminal the terminal window helps configuring the gateway using AT commands e Log file downloads all log records from connected gateway e Call data records information on accomplished calls for telephone bill control and telephone cost logging per party if necessary e Statistics helps download statistic data concerning the count of called minutes incoming and outgoing calls sent SMS etc from the GSM gateway to the PC including saving into a file e Diagnostics shows information on GSM modules and plugged in SIM cards 1 GSM 3G module status 2 GSM 3G module status Layer 2 BLOCK Layer 2 BLOCK Layer 3 NULL Layer 3 NULL Network Network Net ID Sim err Net ID Sim err Net cell 0 000 000 00000 Net cell 0 000 000 00000 Module ID MC55 Module ID MC55 Rev ID REVISION Rev ID REVISION Mod
14. 1 2 The Save to gate button Functions Save parameters to gateway helps upload all configurable items from the selected configuration file refer to Subs 1 2 to the gateway Load from file File Load is used for loading an external file to the configuration program Structure of this file is same as of configuration file which was selected on gateway selection procedure but he content is different a Save to file File Save is used for saving of configuration to a file designated during the gateway selection procedure 8 6 System Parameters Modes Saving call data CDR v Enable system restart Gate ID 0 0 off Save to the gate Load from the gate Default Save to file Fig 36 System Parameter Editing Window The System parameters card reveals settings for CDR Call Detail Records and unit ID 61 2N BRI Enterprise e CDR mode defines calls on which records should be made Data may be recorded on incoming outgoing successful or unsuccessful calls or the CDR mode can be disabled e Unit ID used for designation of the selected GSM gateway in case there are more devices in the network that generate the CDR System restarts Enables automatics restarts of the GSM gateway For example to prevent change PBX s primary synchronisation from PSTN to the GSM gateway in cases of PSTN 2N BRI Enterprise restarts 62 8 7 ISDN Parameters
15. 20 MSN number for TE mode tc35 mode 2 4 atms afms gain 5dB 3 2 5dB 1 0dB 0 2 5d B 2 5dB 4 dtmf space delay 1 99 sec 100 holiday list 01012 1st jan 1231 3 1st dec holiday list2 gsm call delay 0 10 sec dial min max 0 20 dial tout 0 20 sec bitO sim card number 0 imsi l scid bitl siemens connecting tone bit2 don t send CLIP for calls BRI lt GSM bit3 send AoC for calls BRI gt GSM functionless for FW gt 2 03 14 and lower dial O off 1 255 dialtone to GSM ring 0 off 1 255 ringtone to GSM if no PROGRESS from PBX 1 EU dial constantly 425Hz ring 1000 4000msec 425Hz 2 CZ dial 300 300 600 1200msec 425Hz ring 1000 4000msec 425Hz 3 HU dial constantly 425Hz ring 1000 4000msec 425Hz 4 GB dial constantly 425Hz ring 400 200 400 2000msec 400 450Hz gsm causes change table 0 8 causes G 1 netid clir min sms day sec sec2 pseudo G 9 ale conn disc day bits nasms 90 out module 1 2 sim 1 params netid 7 chars clir O netw 1 on 2 off min 0 0ff 1 65535 minutes sms O off 1 65535 day 0 off 1 31 32 everyday sec 2 1 250 pseudo 0 off 1 8 alerting tout O off l send ALERTING on recieveng CIEV form GSM network 2 20sec after recieving PROCEEDING conn delay 0 20sec forced disc bitO sim limit bit 1 time limit bit2 noale day O off 1 31 of clearing group stat bits 0 255 bO notused bl min gt calls
16. Connection is closed Device Server is idle Fig 25 DS Manager window Click the Change IP button to change IP address of BRI Enterprise gateway Clicking the Settings window allows complete configuration of RS232 Ethernet converter which is present in the BRI Enterprise gateway This program allows 40 uploading of new firmware to the converter which is present on the installation CD Settings DS lt 3 50 NL gt Broadcast UDP data Connection mode Fig 26 Ethernet port settings Please keep parameters of RS232 port as shown on the Fig 27 Settings DS lt 3 50 NL gt Fig 27 Configuration of RS232 converter 41 2N BRI Enterprise 6 4 Default connection settings The gateway supports standart telnet protocol For connection you can use any terminal which supports Telnet protocol or configuration tool Gateway supports only one sesstion in one time 42 SECTION 6 Introduction of Configuration Program This section introduces the 2N BRI Enterprise configuration software which is part of the installation CD supplied together with the gateway Here is what you will find in this section e 2N BRI config program Installation e Running of BRI config program 43 2N BRI Enterprise When the installation has been completed run the program by clicking on BRI config program in your PC software menu or clicking on the desktop icon or opening the B
17. RJ 45 connector Chyba Nenalezen zdroj odkaz This connector is not included in all 2N ISDN BRI GSM Enterprise types 1 depends on order number 11 2N BRI Enterprise 2 5 Antenna Connection The BRI GSM gateway has one SMA antenna connector for each GSM module see Fig 5 An external antenna cable is connected to these connectors The external antenna should be installed vertically on a place with a good GSM signal For the technical parameters of the antennas refer to Section 10 Fig 5 Antenna Connection Tighten the antenna connector gently with your hand never use a wrench 12 2 6 Gateway Power Supply Be sure to use only the mains supply adapter that is included in the gateway delivery Before plugging in the gateway make sure that the mains voltage value meets the data given on the mains adapter label Make sure that the antenna has been connected If you connect the gateway to the power supply without an antenna the GSM module transmitter might get damaged Now plug the supply adapter into a mains socket and connect the adapter connector to the gateway see Fig 6 The status indicators indicate the proper operation For their meanings refer to Subs 2 9 Fig 6 Supply Adapter Connection 13 2N BRI Enterprise 2 7 SIM Card Installation Removal Insert the SIM card into the SIM card slots with your hand as shown in Fig 7 Please make sure that the SIM card contact pla
18. Siemens GSM modules only 70 8 9 9 Modules settings This section is dedicated for adjusting of GSM 3G modules only l gt for audio signal from GSM 3G network amplification gt for audio signal to GSM 3G network amplification Allow Siemens tone this function allows to send tones generated by Siemens GSM module while establishing connection to GSM network Use networks Select type of network which will be used after start of GSM 3G module Searching priority Select type of network which will module looking for after start 71 2N BRI Enterprise 8 10 GSM outgoing calls GSM module 1 GSM module 2 GSM call statistics oso Count of minutes h O off 32 every day Max number of called minutes Minute parameter SMS messages number Day of deleting stats SMS at no answer Default delay before send SMS s 0 off p S Text for SMS at no answer ZN in the message will be replaced by calling party number GSM calls statistics settings Number of seconds after connect j 0 off h Nr of seconds for next counting AOC settings z Send CLIP from ISDN to GSM Attention Must be supported by your GSM 3G operator In other case outgoing calls to GSM 3G can be rejected Transfer CLIP to GSM parating cha Roaming enabled for network code CLIR function Default v Never v Disconnect call
19. is set to operate as a pass through gateway with respect to incoming calls while outgoing calls are routed according to the ISDN BRI GSM gateway LCR table Chyba Nenalezen zdroj odkaz shows the ISDN BRI GSM gateway as a pass through router for a Point to Multipoint connection Calls are routed automatically to the GSM network or ISDN according to the GSM gateway LCR table The GSM gateway DTMF is not needed in this arrangement Fig 20 BRIISDN GSM Gateway Connection as Pass Through Router with PBX Mrkni na koment napravo u tu byl p edt m 28 SECTION 5 Telephony via the GSM Gateway This section contains information on routing calls through the GSM gateway Gateway configurations are described that help you make the most of the gateway potential and minimise your telephone costs This section includes 29 2N BRI Enterprise Functions Supported by Call Routing Rules LCR table Routing of Outgoing GSM Calls Routing of Incoming GSM Calls DISA Message Recording 30 5 1 Functions Supported by 2N BRI Enterprise gateway e Call routing according to time and called destination through the destination s operator e Auto CLIP routing e Outgoing call routing by time LCR Least Cost Routing e DISA tone dial in e DISA to GSM tone dial in from ISDN ports to GSM networks e CallBack to GSM e Virtual Ring Tone e SMS sending receiving e SMS at no Answer e Password for configur
20. list of called numbers which will be called to ISDN network in case that an incoming call from GSM network will not contain correct called party number or the timeout Wait for next digit s expires Numbers are dialed down from top 78 8 11 5 Dynamic CLIP routing settings e Record validity h for time validity of record in dynamic CLIP routing table Value 0 disables this function Dynamic CLIP routing allows to route calls from GSM network directly to the extension which was the last time connected with the GSM network user e Create record for unconnected calls only sets saving of unconnected calls to the dynamic CLIP routing table The record will be added in case the call was is not connected only e Erase record after using setting of this parameter enables deleting of the record from the dynamic CLIP routing table after the call connection 8 11 6 Day of deleting statistics Defines a day in a month on which statistical data on incoming calls are deleted By setting this parameter at 0 you disable this function 8 11 7 Prefix before DISA e Prefix before DISA a digital prefix to precede the DTMF automatically 8 11 8 Looping of voice message e Voice message loop min DISA for incoming calls is repeated for time interval filled in this field in minutes Value 0 for playback DISA record only once 8 11 9 Recognition CDN in CLIP Specifics function for some GSM networks which sup
21. port installation Welcome window Install all optional parts of the installation as is shown on the Fig 22 and continue in installation clicking the Next button 38 InstallShield Wizard Select Components Choose the components Setup will install Server Manager v Connection Wizard Virtual Serial Ports Help Files Installshield Fig 22 Selection of optional part of installation Wait until the installation successfully finishes InstallShield Wizard Setup Status 0 TECHNOLOGY InstallShield Fig 23 End of installation In the following window check Open program folder checkbox See Fig 24 39 2N BRI Enterprise InstallShield Wizard l InstallShield Wizard Complete 1 Setup has finished installing Tibbo Device Server Toolkit on your computer Back Cancel Fig 24 Open program folder checkbox 6 3 Ethernet port configuration The DS Manager is possible to run from the installed program folder E B xl Soubor pravy Zobrazit Obliben N stroje N pov da l a IQ AB Ode fio eme GS AS NE MAM IR EL SIENTEN TEE In x Adresa JE capec pL Access mode Loca Device Servers auto discovery by broadcast v Refresh Ree uic JF One Devicon qu 192 168 1 10 local 2N 2N BRIE vs Manager Initialize Routing Status Buzz Change IP Device Server is operating normally gt
22. right template 44 7 2 1 Templates In case of not defined configuration file first start of congiguration tool or by D use icon or by menu File gt Default configurations By using template you can load default configuration basic settings for your type of gateway and installation site type Default configurations 2N BRI Enterprise in dialthru mode briet ini 2N BRI Enterprise with external synchronisation on TE port brieTE ini 2N BRI Lite on NT port all call will be routed to GSM 3G networks brilnt ini 2N BRI Lite ISDN port as TE with activated DISA on TE port brilte ini When default configuration is used current configuration will be lost Cancel 7 2 2 Gateway list For administration of only one gateway is the following procedure not necessary Itis possible to operate with default configuration file which name is unnamed cfg and is saved in directory with configuration program Saving parameters to the configuration file is automatic by switching items in topic or alphabetical glossary tag To facilitate the administration of more than one 2N BRI Enterprise gateway it is possible to use Gateway selection window This window is located in menu Gateway Gateway list see sub 1 3 Selection of this opens window shown at Fig 28 45 2N BRI Enterprise Connect Cancel Fig 28 Gateway list Window e Add click on Add to open a wi
23. 0 07 3 0 0 1 0 g01 inc 0 00 0 0 00 00 0 0 0 0 0 module reset minutes hhhh mm ss calls reject failed c offs smses g00 out 0 00 1 0 01 24 6 0 0 4 0 g01 out 0 00 1 0 01 08 5 0 4 5 0 End of Module statistics End of stats record e Pri grp call type e Reset Last statistic reset date e Minutes Number of minutes Hhhh mm ss Same number converted to time Calls Number of calls e Reject number of unconnected calls no free GSM module available call rejected with a cause 41 42 103 2N BRI Enterprise 104 Failed number of unconnected calls rejected by the GSM network C offs number of unconnected calls terminated by the calling party Errors number of unconnected calls wrong reguests dialled prefix etc Red in number of connected calls re routed to this GSM group Redout number of connected calls re routed to another GSM group smses Number of sent SMS messages l SECTION 4 Technical Parameters GSM GSM 850 900 1800 1900MHz UMTS 3G Mobleinetwon type according to the GSM 3G module used SIM card plug in 3 V small Upto ZW Receiver sensitivity 104 dBm Antennas F 850 900 1800 1900 2100 MHz depending on the gateway reguency hoe ree Maximum oulpul power Antenna connector type SMA male Number of antennas 1 or 2 according to the gateway type Cable length 3 10 m or without cable 105 2N BRI Enterprise Pow
24. 2N BRI Enterprise TELECOMMUNICATIONS User Manualversion 2 0 RUAS Dear customer let us congratulate you on having purchased the 2N BRI Enterprise system This new product has been developed and produced in order to provide the maximum utility value quality and reliability to the user We hope you will be fully satisfied with the 2N BRI Enterprise for a long time The manufacturer constantly improves the software contained in the product the so called firmware The technology used therein helps you download the latest firmware version to the 2N BRI Enterprise gateway using a common PC anytime For the latest firmware version see www 2n cz For necessary instructions refer to Section 7 2 hereof We recommend you to apply the latest version to avoid problems that have already been eliminated marked text of this User Guide specifies functions of the gateway which will be supported in newer versions of firmware You also find the latest version of the User Manual at ww w 2n cz Check your delivery for completeness according to the packing list and study this manual carefully before installing this product The manufacturer shall not be responsible for damage caused by any use of this product in contradiction with the User Manual The warranty terms and conditions do not apply to damage incurred as a result of gross handling and or undue storing of the product or violation of the technical parameters included herein Th
25. C amp CR amp BSYS cmd amp XG amp XG amp M0 amp MI1 amp M9 amp U AH view Icr routing table lt SPACE continue gt view bris modules totals View all modules totals send at command to module 0 1 ended by OK from gsm send at command to module 0 1 ended by CR from user cmd for module 0 1 RESET BLOCK OFF DOWN ON ATBAUD cmd for module 0 1 RESET BLOCK OFF DOWN ON View aux bris modules status View aux bris one module status ax px ex 0 1 View all modules selected info by at amp S view signal quality on module 0 1 View signal quality on all modules view logfile from recent lt SPACE continue gt View buffer calls from recent lt SPACE continue gt read buffer from the oldest lt erase amp continue cmd for system RESET View conn table gsm call states View call details for gsm channel disable ansi colors enable ansi colors Start matrix View logged users view gsm moninfo dBm sigan level whn registering with BTS RxLEV minimum signal level required by BTS for registering of GSM module Configuration AT Commands System Settings S85 sms S90 mode S91 buf id S92 rep S98 pin S99 dd mm yy w hh mm ss X10 tsec X20 mmdd mmdd 88 NO answer sms text max 63 chars operating mode of GSM module allocation O cyclic mode 1 locked mode 2 smart mode accor
26. FILE Content of call file is being written out 5 CALLREAD Call file records are read 6 AUTOFILE Content of incoming call autorouting chart is being written out 7 QUERY not used so far 8 SCREEN not used so far 9 MATRIX Active matrix screensaver 10 FUNCFILE Content of debug file is being written out 11 LCRFILE not used so far Telnet Status Messages ID Name Description 0 LOGOUT User logged out 1 LOGIN User is entering name 2 PASSW User is entering password 3 IDLE User logged in Records of Events and Calls Records on Events and Calls ID Name Description 0 POWER System power on power off or reset 1 INIT Initialisation of EEPROM configuration or flash upgrade 3 SYSERR System error memory error etc 8 L1 ERR BRI port layer 1 error ISDN1 9 L2 ERR BRI port layer 2 error ISDN2 10 L3 ERR BRI port layer 3 error ISDN3 12 G2 ERR GSM module layer 2 error gate2 13 G3 ERR GSM module layer 3 error gate3 14 C4 ERR Link layer error call4 Types of Records in Call Record File ID Name Description 0 LkFD Not connected incoming call attempt 1 OK Connected incoming call 8 O FD Not connected outgoing call attempt 9 O OK Connected outgoing call 99 2N BRI Enterprise 9 7 Records on Operation LOG Type Text Description POWER Power on System switched on Power off System switched off Warm boot Res
27. I 3 OKTEI TEI Assigned 4 AWEST Awaiting Establishment 5 AWREL Awaiting Release 6 OKEST Multiple Frame Established 7 TIMREC Timer Recovery ISDN Layer 3 Status Messages ID Name Name according to Q 931 Description on NT interface Description on TE interface 0 NULL Null Rest status ready for call 1 CINIT Call Initiated Call from BRI indicated Call to BRI started 2 OVSEND Overlap Sending Gradual dialling receiving Gradual dialling sending 3 OPROC Outgoing Call Proceeding Dialling from BRI terminated Dialling to BRI terminated 4 CDELIV Call Delivered Call from BRI ringing Call to BRI ringing 6 CPRES Call Present Call to BRI started Call from BRI indicated 7 CRECV Call Received Call to BRI ringing Call from BRI ringing 8 CONREQ Connect Request Call to BRI answered Call from BRI answered 9 IPROC Incoming Call Proceeding Dialling to BRI terminated Dialling from BRI terminated 10 ACTIVE Active Connected call 11 DISREQ Disconnect Request End of call from BRI End of call to BRI 12 DISIND Disconnect Indication End of call to BRI End of call from BRI 19 RELREQ Release Request Channel release request 25 OVRECV Overlap Receiving Gradual dialling sending Gradual dialling receiving 61 RSTREQ Restart Request Channel restart request sent 62 RSTART Restart Channel restart request received Management Status Messages ID Name Description O INIT Initialisation upon BRI reset
28. ISDN BRI 1 port settings Interface NT Point to point v jo 0 63 64 dynamic TEI Mode TEI managament Dialling mode ENBLOCK v Digits in SETUP 20 ISDN BRI 2 port settings Interface TE Point to point X o 0 63 64 dynamic TEI Mode TEI managament MSN number nn DIS dial tont Tone signalling for calls to ISDN Dial tone None X Ring tone None v Progress elements numbers Message SETUP ACKNOWLEDGE ja 2j0 0ft 8 0 off Message SETUP PROCEEDING Generating busy tone ToBRI1 for si seconds seconds ToBRl 2 for jo 3 0 0 s S to otf Message SETUP PROGRESS Message SETUP ALERTING Release causes to ISDN Lack of digits in OVERLAP mode 102 Restricted number prefix 21 gt Selected module GSM group is not rea n Ke st No module GSM group is ready Numbering plan settings jo b si Called party number Calling party number Receive dial number from subaddress Don t send Connect ACK message in TE mode p si Day of deleting statistics ISDN Fig 37 ISDN Parameter Editing Window The ISDN parameters card is used for setting all ISDN port parameters To set the gateway default values click on Default Individual items are explained below according to their respective groups in the editing window 63 2N BRI Enterprise
29. R buffer state LI GSM incoming calls KA Connection state 7 GSM monitor info R GSM monitor info L GSM outgoing calls LA Test calls 4 Info about actual calls k Online commands 4 ISDN parameters LA Show dynamic CLIP routing table 4 ISDN port modes Gateway configuration 4 LCR table 3 System parameters C LOG file 3 ISDN parameters 4 Login account L ISDN port modes 4 Online commands GSM basic parameters C Prefixes GSM outgoing calls C Statistics L GSM incoming calls System parameters 7 Prefixes C Terminal 7 LCR table C Test calls 7 Autorouting table L Tracing 57 Restart L Voice message Gateway restart 3 Factory parameters restart 2N BRI Enterprise Fig 35 Topic List left and Alphabetical Glossary right SECTION 2 Configuration This section describes the 2N BRI Enterprise setting using the GSM configuration software that is part of the installation CD supplied together with the gateway This section includes e 2N BRI Enterprise Gateway Communication Establishing e Firmware Version Identification 58 Gateway License Load Save Parameters System Parameters ISDN Parameters ISDN port modes 8 1 ISDN port modes ISDN BRI 1 port NT interface Reject all incoming calls Route calls to ISDN BRI 2 port Use LCR table then reject a call Use LCR table then route to BRI 1 port ISDN BRI 2 port TE interface Reject all incoming calls
30. RI config program exe file that you will find in the respective location installed by you using any explorer or file browser Note BRI config program is designed for 2N BRI Enterprise and BRI lite GSM gateway type Type of connected gateway is detected automatically configurations windows are changed accordirg gateway type or by selecting right template e Templates e Configuration Program Basic Menu e Button Bar e Topic List and Alphabetical Glossary 7 1 2N BRI config program Installation By inserting the installation CD in the CD ROM drive you initiate installation automatically If you have not enabled the CD autorun function initiate installation by opening the setup exe file of the BRI Enterprise software Follow the installer instructions and wait until the installation has been completed The guides and autoupdate program are installed together with the 2N BRI Enterprise software 7 2 Running of BRI config program When the installation has been completed run the program by clicking on BRI config program in your PC software menu or clicking on the desktop icon or opening the BRI config program exe file that you will find in the respective location installed by you using any explorer or file browser Note BRI config program is designed for 2N BRI Enterprise and BRI lite GSM gateway type Type of connected gateway is detected automatically configurations windows are changed accordirg gateway type or by selecting
31. Removal of the TE progress from corfirmation message in ISDN communication It is neccessary to use this parameter with some of Alcatel PB Xes e g Alcatel 4400 8 7 8 Receive dial also from Subaddress element Some ISDN terminal are sending letters and as Keypad facility dial mode With activate this parameter gateway will convert this dial to Called party number 66 8 8 ISDN port modes f ISDN BRI 1 port NT interface Reject all incoming calls Incoming calls will be routed to GSM or opposite ISDN BRI port according to LCR table If there will no be valid Route calls to ISDN BRI 2 port line call will be rejected Use LCR table then reject a call f UseLCR table then route to BRI 1 port ISDN BRI 2 port TE interface Reject all incoming calls All incoming calls from this interface will be routed directly to the opposite ISDN BRI port This settings ignores LCR Route calls to ISDN BRI 1 port table Use LCR table then reject a call Use LCR table then route to BRI 2 port GSM channels 1 and 2 Reject all incoming calls Incoming calls will be processed according to GSM Pel eel Speed eer d PR Fae hey eet incoming calls settings and routed to ISDN 1 port if pou Route incoming calls to ISDN BRI 1 port set so Route incoming calls to ISDN BRI 2 port Major route settings for GSM and ISDN BRI ports 67 2N BRI Enterprise 8 9 GSM parameters
32. ages This function along with other additional functions enhances the utility value of the product No extra equipment an external GSM telephone etc is needed for normal operation All programmable parameters are default preset in such a manner that you can commence your telephone traffic the moment you connect the USB and supply cables antenna and SIM card and set the ISDN and GSM parameters 1 2 How to Cut Telephone Costs Once your 2N BRI Enterprise gateway has been connected to your ISDN PBX all calls going out to a mobile network are made directly This saves your PSTN mobile network call costs All mobile telephone calls of your personnel in the field are cheaper too You are advised to use the most advantageous rate of your GSM provider for your GSM gateway because all gateway user call accounts are added up for billing purposes You can block groups of numbers in your gateway You shall pay nothing for the calls you have barred 2N BRI Enterprise keeps detailed records on all calls This helps you to find out easily why your bill is higher than it should be The Least Cost Router is flexible enough to help you set rules for GSM calling at the lowest possible operation costs The intelligent CallBack function enables your personnel to call at the cost of your GSM gateway SIM cards 1 3 Other Advantages and Applications optional 2N BRI Enterprise gateways integrates the best of their respective commu
33. ation of the gateway on all ports e CLIP and CLIR for incoming calls from GSM network e ENBLOC OVERLAP mode of sending called number to ISDN network e Remote control over GSM CSD 5 2 Call Routing Rules 222 Zkus m n co vymyslet The GSM gateway ports are logically divided into internal and external While GSM ports are external only ISDN port is internal You can define whether your internal port calls should be routed to external ports or to the operator or according to the active DISA function tone dial in Furthermore you can route calls according to the CLIP MSN Multiple Subscriber Number for ISDN extensions or direct GSM gateway dial in ISDN extension with DDD If an outgoing call is routed via a port that is busy the remaining available ports are searched for depending on the configuration and if no allowed outgoing port is free the outgoing call is rejected with defined depending on the configuration ISDN release cause 3 Must be activated by proper licence code 31 2N BRI Enterprise The routing algorithm routes outgoing calls according to the outgoing call type current time rate day in a week and GSM provider s free minutes if any depending on the configuration 5 3 LCR table The LCR Least Cost Routing chart is the key telephone cost cutting factor It helps you set the call routing rules according to the CLIP daytime and day in a week By entering public holidays into the LCR
34. ax 63 chars pref list extension max 63 chars pref list extension max 63 chars pref list extension max 63 chars pref list extension max 63 chars 91 2N BRI Enterprise N7 pref dig pref list extension max 63 chars NH9 netid max network id 7 chars default max digits 0 20 92 Routing Paramaters A clip dial limit set autorouting item ix 0 95 clip 20 dial 20 limit O off 1 99 minutes R net hh mm hh mm w groups lim set Icr routing item ix 0 63 totals first m c s second m c s riro TB m c m c TBALL m c m c TG m ri ro TGALL m c ri ro Ti m c TIALL m c T 1 m c s m c s TALL 1 m s m c s Tracing commands ATIRE AT Lx AT Rx AT RR AT RX net 1 8 groups max 7 chars 1 3 9 3 any module 9 bri2 call limit O off 1 99min last LCR table line must be empty inc minutes calls smses out minutes calls smses redirected inc out calls init minutes calls in bri 0 65535 init minutes calls in all bris 0 65535 init minutes calls rin rout in group 0 65535 init minutes calls rin rout in all groups 0 65535 init minutes calls in inc group 0 65535 init minutes calls in all inc groups 0 65535 init minutes calls sms in mod sim 1 0 65535 init minutes calls sms in all mods sim 1 0 65535 Start tracing of error messages active i
35. b2 notused b3 notused nasms tout O off 1 20sec G9 mode min max tout day dial clip o GOH XXX XXX XXX G99 exp bits G19 mess Pseudo paramaters P01 uuu HH MM P02 uuu HH MM P03 uuw HH MM 0P04 uuu HH MM P05 uu0 HH MM P06 uuw HH MM P07 uuu HH MM P09 mode sec Networklist Parameters N 0 opx npx N 1 pref dig N 2 pref dig N 3 pref dig N 4 pref dig N 5 pref dig N 6 pref dig inc module 1 2 params mode 0 reject 1 ignore 2 ok message 3 ok tone mode 4 7 0 3 autocallback 6 7 ext callback min 0 20 max 0 20 tout 0 20 sec dtmf dial in day 0 off 1 31 of clearing inc group stat dial prefix max 15 ch clip prefix max 7 ch auto dials max 63 chars 5 8 for inc groups 1 4 dynamic clip expire O off 1 240 hours bitO add conn bitl rem answ params 1 4 for inc groups 1 4 mess duration O once 1 99 repeated minutes pseudo tarif 6x cents until cents 1 9999 until 00 00 first item is all weekend until 24 00 last mandatory item pseudo tarif extension pseudo tarif extension pseudo tarif extension pseudo tarif extension pseudo tarif extension pseudo tarif extension pseudo mode O off 1 cdr 2 cdr isdn isdn sec 1 250 list of old new main prefixes max 47 chars list of prefixes digits to end max 63 chars pref list extension m
36. cessfully connected incoming call will be implemented in a higher firmware version e O FD Unconnected outgoing call attempt e O OK Successfully connected outgoing 4th column CAUSE sent to ISDN 5th column used B channel number used GSM module number 6th column used GSM group C CallBack Jih column call establishing time 8th column call duration mmm ss max 255 59 or error cause for unconnected calls Oth column call cost will be implemented in a higher firmware version 9th column gateway id optional 10th column called number 11th column caller s MSN number 12th column slot number used SIM card IMSI or SCID Siemens modules only 9 9 Statistics Description Note Format of statistics are same as in BRI Lite gateway Lines which contains BRII Pxx settings are used as NT BRI2 Exx as TE interface Total statistics network reset minutes hhhh mm ss calls reject failed c offs errors bri1 inc 0 00 2 0 02 21 10 4 4 18 0 fibri2 inc 0 00 0 0 00 00 0 0 0 network reset minutes hhhh mm ss calls reject failed red in redout bri1 out 112 0 0 00 07 3 0 0 0 0 bri2 out 1 12 0 0 00 00 0 4 0 0 0 module reset minutes hhhh mm ss calls reject failed c offs smses mods inc 0 00 0 0 00 07 0 0 1 0 mods out 0 00 2 0 02 32 11 0 4 9 0 End of Total statistics Module statistics module reset minutes hhhh mm ss calls reject failed c offs smses g00 inc 0 00 0 0 0
37. cuiting may result in battery destruction or explosion Keep the proper battery polarity Dispose of used batteries in accordance with applicable waste regulations for example in waste recycling CR2032 USB connector 10 100 base T connector optional Fuse Power connector Fig 13 Motherboard Diagram The lithium battery only supplies the real time internal clock in the 2N Enterprise gateway in the event of power failure It is unnecessary for the depends on gateway order number 19 2N BRI Enterprise gateway functionYou are recommended to replace it after three years for preventive purposes or at least check the voltage with a voltmeter the value should not drop below 2 9 V A completely low battery results in the 2N BRI Enterprise gateway losing the time and date information false data appear also in the service log buffer listing Replacing the lithium battery first disconnect your 2N BRI Enterprise gateway from the mains and open the cover Remove the old battery from the holder using a suitable tool and install a new one 2 11 Fuse Replacement WARNING Use only a fuse of the same type Disconnect the adapter power while replacing the fuse Fuse can be replaced only by service which is personnel qualified to check such parameters as power consumption DC voltage etc If fuse fails again unit must be returned to manufacturer for repair To exchange the fuse disconnect powe
38. cussed in Subs 1 12 Outgoing interface this list is used for selecting of outgoing interface All outgoing calls are routed to the respective interface according to the selected prefixlist The routing priority is from top to bottom Therefore if the top parameter GSM module 1 cannot be used the call is routed according to the parameter under the first one GSM module 2 Setting of routing according to Any group module is required if the parameter GSM parameters General GSM module selection is set up to Cyclic or Smart Use ISDN TE interface to set up routing of calls to TE port according to prefixes in Prefixlist e Time limitation of use sets the time limit for the routing rule defined in this menu The time validity From To may include weekends too e Max length of call limits the call duration to the network selected in Network number through the GSM group selected in Groups To disable the call duration limitation set the value at 0 e Edit you can edit a routing rule from the LCR table by pressing this button e Remove deletes a routing rule selected from the LCR table list Holiday List e Holidays list enter the public holidays to optimise your telephone costs with the LCR e Date to move to summer time dd mm enter the day on which winter time should be changed into summer time for LCR purposes e Date to move to winter time dd mm enter the day on which summer time s
39. ding to already called minutes for 0 and 2 set LCR group 3 any cdr mode b0 outg b1 inc b2 failed b32moninfo unit id O off 1 255 report mode bO states b1 tstamp b2 smp b3 lay2 b4 select sim pin max 7 digits Set date time w 1 7 day of week external routing tout in sec 10 5 60 255 date of hour 1 hour 1 time change O off 0101 1231 X22 hh mm X80 login pass X40 GSM BRI1 BRI2 0 System Conirol AT amp Gxx RESET AT amp Gxx BLOCK AT amp Gxx DOWN AT amp Gxx ON ISDN Seitings 100 xxx 101 tei mtp 105 c1 c2 c3 c4 0 01 23 59 time of reset of GSM gateway 0 00 no reset login name password max 15 chars all basic port routing GSME 0 incomming GSM call rejected GSM 1 incomming GSM calls will be routed to BRII GSM 2 incomming GSM calls will be routed to BRI2 BRI1 0 all calls from BRII will be rejected BRI1 2 all calls will be routed to BRI2 BRI1 G routing to GSM by LCR table BRI1 A routing to GSM by LCR table then BRI2 BRI2 0 all calls from BRII will be rejected BRI2 1 all calls will be routed to BRII BRI2 G routing to GSM by LCR table BRI2 B routing to GSM by LCR table then BRI1 Reset of GSM module No xx Block of GSM module No xx Transfer of GSM module into the sleep mode Transfer of GSM module into the idle mode BRI protocol mode NT as Network termination mode NTS Network termination mode with activated external synchronisation o
40. e identify the current firmware version in the Functions Other functions Firmware License menu and compare it with the one available on our websites www 2n cz or on attached CD If your GSM gateway firmware version is older than that distributed by us upload the latest firmware version to your GSM gateway Please follow the instructions included in Gateway control in Subs 1 3 3 Please do not hesitate to contact out technical support personnel in the case of troubles Since the product is subject to innovations please check the latest firmware version on our websites regularly 8 4 Gateway License The operation of every new 2N BRI Enterprisecan be limited to 850 hours Every gateway reset reduces the remaining gateway operation time by one hour 60 To identify the GSM gateway status use the Functions Firmware License menu for the gateway unlocking procedure refer to Functions in Subs 1 3 3 If you require additional license please contact your sales person depends on gateway s order number 8 5 Load Save Parameters Use task bar or configuration program basic menu To download configuration file from the gateway Upload of the configuration parameters to the gateway is possible by similar way 5 The Load from gate item Functions Load parameters from gateway helps download all configurable items from the gateway and save them into the file designated during the gateway selection refer to Subs
41. e sent for any of the following events e Lack of digits on OVERLAP mode the incoming call was rejected because the number of digits of the calling party s dialling was too low for successful connection default 102 Recovery on Timer Expiry Restricted number prefix call rejection due to an unknown prefix The prefix does not match any item in the routing tables default 2 21 Call Rejected Selected module GSM group is not ready call rejection due to the busy status of all modules that have been selected for routing calls to the particular destination the module assigned to the B channel group is not available and no other GSM modules have been selected for the destination default 41 Temporary Failure 65 2N BRI Enterprise e No module GSM group is ready call rejection due to the busy status of all modules that have been selected for routing calls to the particular destination and alternative GSM modules that have been selected routing calls to the particular destination in case of congestion default 42 Switching Eguipment Congestion Complete list of available release cause you find under button 8 7 6 Numbering plan settings These parameters are for set numbering plan values for Called party CDN and calling party number CGN Please do not change it without detailed knowlodge of ISDN DSSI signaling 8 7 7 Don t send Connect ACK to BRI2 TE
42. eated unsuccessful send of packet SABME H repeated DM Repeated unsuccessful send of packet DM I failed TIMREC Unsuccessful breaking up of status TIMREC J N R error Received wrong value N R numbering of packets K recv FRMR Received packed FRMR information about error L undef frame Received unknown type packed M I field Received wrong I packet numbered packet N frame size Received packed with wrong length O N201 error Value N201 was exceeded max length of packet L3 ERR tout sts p Error of isdn layer 3 timeout in status on channel p 100 Type Text Description G2 ERR ATD ERROR init gf Error of isdn layer 2 restart of module g after rejected command ATD by GSM network GSM Cause 150 git Error of isdn layer 2 restart of module g after cause 150 was received call barred by GSM network G3 ERR tout sts g Error of isdn layer 3 timeout in status on module git C4 ERR tout sts p g Error of connecting layer 4 timeout in status on call between channel p and GSM module g 101 2N BRI Enterprise 9 8 Records on Calls Example of a successfully connected call 06 12 05 15 44 57 O OK CAU 016 p01 g01 GRP 3 0 18 00000 00 737111074 112 1 230030102122930 102 e ist column 2nd column call start date time 3rd column call type e call I FD Unconnected incoming call attempt will be implemented in a higher firmware version e I OK Suc
43. ed udo sli osa dy c t 13 2 7 SIM Card Installation Removal dete t e oer eve tese ee eh tate 14 2o 7 NT and TE Connection acc a Dm aee eet tai cd Sube don 14 2 Status ITI Cato So O RAN HENARES u bod oa edu 16 2 10 Lithium BatteryoRep lacement ooo PRIM 19 ZI Fuse Replacement uu oed erae d sn guia iso dis bacs 20 SECTION 3 ISDN BRI EXTENSION CONFIGURATION 21 3d dPonmtto Pornt COMME CH OM esi situe esaea oera ras Eaa AAE AES AS 22 3 2 Point to Multipoint Connection eese 22 SECTION 2 BRI GSM GATEWAY CONNECTION OPTIONS 23 4 1 Connection of ISDN TE to 2N BRI Enterprise ee 24 42 2N BRI Enterprise Point to Point Connection eeee 25 4 3 2N BRI Enterprise as Pass Through Router 27 SECTION 5 TELEPHONY VIA THE GSM GATEWAY 28 5 1 Functions Supported by 2N BRI Enterprise gateway e 29 5 2 Call Routing Rules Zkus m n co vymyslet u 29 eo DE ECR Eire O O O O 30 5 4 Routing of Outgoing GSM Calls eee eee eee eee 30 5 5 Routing of Incoming GSM Calls care CR URINE ote URe RORcieh 32 2N BRI Enterprise 5 6 DISA Message Recordi t Asusu aa aa ea ooo 33 SECTION 6 ETHERNET PORT CONFIGURATION 35 6 1 Default connection Settifi9s eo beri RUE E PR eR Ee eR PRENDAN RARUS RS 36 6 2 Installation of Ethernet port drivers eese 36 6 3 Ethernet port configuration u oe toris ERR eR Es ure to
44. elephone number is not transmitted to the GSM network CAUTION Some GSM providers do not support this function which might lead to rejection of an outgoing call Disconnect call Disconnect call the currently made call is disconnected in cases included in the pull down menu Statistics Day of deleting stats in group defines the day on which statistic data on disconnected calls are deleted Messages to ISDN Delay before send CONNECT s a delay before sending information on a connected call after reception from the GSM network Delay for ALERTING s timeout for generating of ALERTING message by the GSM gateway in case the gateway does not receive ALERTING message from GSM network 75 2N BRI Enterprise 8 10 9 Send CLIP from ISDN to GSM Feature for forwarding CLIP from ISDN to GSM network This feature MUST be supported by your GSM provider In otherwise there can be reject of outgoing calls to GSM network 8 10 10 Time limitation of SIM card Interval of using SIM card 8 11 GSM incoming calls GSM module 1 GSM module 2 List of called numbers Mode Mode Reject incoming calls Refuse calls DISA DTMF settings Minimum digits in DTMF 3 Add Remove Remove all Maximum digits in DTMF 3 2 Day of deleting stats 2 Timeout while inputing DTMF digits s 10 n 0 off 1 E Dynamic CLIP routing settings Time to keep CLIP in table hours 0 oft 0 si odejde
45. er Supply 110 230 V 50 60 Hz 12V DC DC power supply 12VDC 1A Supply connector DC jack 2 1 mm Lithium battery CR2032 only models with serial number XX XXXX XXXX ISDN So point to multipoint Type of BRI ISDN NT connection So point to point Type ofBRI ISDN TE connection So pomit to multipoint So point to point ISDN protocol EurolSDN DSS 1 Type ISDN connector 2x RJ 45 NT interface supply from an external adapter or ISDN Communication Interface JE Optiona o Others Dimensions w o connectors 250 x 150 x 55 mm Operational temperature 0 C to 45 C Relative humidity 5 to 95 106 TELECOMMUNICATIONS 2N TELEKOMUNIKACE a s Mod ansk 621 143 01 Praha 4 Czech Republic tel 261 301 111 fax 261 301 999 e mail sales 2n cz www 2n cz PR 1272 v2 0 107
46. for tag names 55 2N BRI Enterprise 7 3 5 Help This menu is available under Alt h e About opens a window providing information on the configuration software version together with contacts to the technical support personnel 7 4 Button Bar The button bar Fig 34 displays the most frequently used commands that make the work with the GSM gateway easier and quicker Exit Terminal Language selection Save CFG to gateway Load CFG from gateway Disconnect gateway Connect with gateway Save CFG to file Load CFG from file Open templates list Fig 34 BRI config program Button Bar 7 5 Topic List and Alphabetical Glossary Select the more convenient of the two arrangements of configuration program items 56 Fig 35 The topic menu is divided to two sections Gateway control There are located items which are available only when gateway is connected Gateway control Connected lt KA Login account Gateway control Gateway control Offilne x Loi account M E ecu The sections below are arranged according to the e time que LA Firmware Licence 4 Autorouting table Topic list lA Tracing 7 Call data records lA Terminal CDR buffer state lar LOG file 7 Connection state KA Call data records 7 Date time LA Statistics 3 Diagnostics LA Voice message 7 Firmware Licence lat Diagnostics 7 Gateway configuration KA Info about actual calls GSM basic parameters R CD
47. he dial tone or voice message and awaits DTMF digits Limit setup the maximum length of call Value 0 disables this function Edit for editing of autorouting table records Clicking this button opens the window shown on Chyba Nenalezen zdroj odkaz Remove for removing of autorouting table records Clicking this button removes selected record from the table 84 SECTION 3 Configuration Using Terminal It is possible to communicate with the 2N BRI Enterprise through a USB The connection allows for a uniform way of gateway configuration using AT commands This section includes e USB Communication Settings e LAN Communication Settings e Transmission rate 921600 bps Data bits 8 Parity none Stop bits 1 Flow control none 9 1 LAN Communication Settings To communicate with the 2N BRI Enterprise gateway through the LAN set the LAN IP address first To do this you need a direct USB PC connection You can use such programs as HyperTerminal Putty etc for communication IP address gateway address set by you 85 2N BRI Enterprise Port 23 The gateway requires username USER and password PASSWORD for login The gateway responses with OK message after the entering of correct identification data e Terminal Communication e List of Terminal AT Commands 9 2 USB Communication Settings You can e g use the HyperTerminal communication software for communicatio
48. hining If a GSM module is not supplied the respective GSM LED is blinking red After a correct GSM module initialisation the SIM card starts logging into the provider s network which is indicated by a guickly blinking green colour If the log in has been successful the LED goes out If not it shines red In normal operation a slowly blinking green LED indicates establishing of an incoming or outgoing call and a permanently green LED means a successfully established connection within the respective GSM module A survey of GSM module status signalling is included in Tab 3 GSM indicators GSM 1 or GSM 2 LED colour status The module is ready and logged in No light Call establishing Green blinking slowly 1 1 Currently made call Green shining SIM card initialisation Green blinking quickly 1 1 SIM card initialisation in progress Shining red GSM module SIM card absent Red shining GSM module not supplied Red blinking quickly Tab 3 Survey of GSM Module Status Signalling 18 2 10 Lithium Battery Replacement Lithium battery contains only models with serial number 09 XXXX XXXX WARNING An incorrect battery replacement may result in explosion For replacement batteries of the same or equivalent type as recommended by the manufacturer may be used only The battery type is CR2032 WARNING Never use metal tools for battery replacement to avoid short circuit Battery short cir
49. hould be changed into winter time for LCR purposes 8 14 Autorouting Table Autorouting table is a tool for permanent routing of incoming calls from GSM network to respective extensions Moreover the Autorouting table serves for managing of Callback function for incoming CLIPs from GSM network 83 2N BRI Enterprise e Add this button is intended for adding of new record to the autorouting table The window shown on the opens by clicking this button GSM number CLIP field for the GSM number for which will be autodial or autocallback function applied CLIP must be entered in the same format as is presented by GSM network the same as is for incoming calls shown on GSM phone display Dial to ISDN incoming GSM calls will be routed to the ISDN extension number filled in this field e Autodial selecting this item all incoming calls with CLIP filled in GSM number CLIP will be routed to the extension number filled in Dial to ISDN field e Autocallback selecting of this item activates Autocallback function The autocallback routine is activated after the calling party in the GSM network hangs up If the field Dial to ISDN is filled in the BRI Enterprise establishes connection to the extension in the ISDN network while establishing of the call to the GSM network If the Dial to ISDN field is empty the BRI Enterprise establishes connection back to the GSM and after the accepting of the call plays back t
50. indicates the status of the B channels between the GSM gateway and ISDN terminals NT while BRI 2 relates to the B channels between the GSM gateway and network termination TE or your PBX see Subs Chyba Nenalezen zdroj odkaz BRI 1 BRI2 green BRI1 BRI2 LED colour status Channels are not occupied and physical and data link layers are activated no light TEI binded link layer not activated Orange BRI 1 or BRI 2 are shining 1 B channel towards TE is occupied Green BRI 1 is shining 2 B channels towards TE are occupied Green BRI 1 is shining 1 B channel towards NT is occupied Green BRI 2 is shining 2 B channels towards NT are occupied Green BRI 2 is shining TE not connected Red BRI 1 is shining Physical layer activated Red BRI 1 or BRI 2 are blinking NT PBX not connected Red BRI 2 is shining Physical layer activated Red BRI 2 are blinking Tab 2 Survey of BRI 1 BRI 2 Indicator Statuses 17 2N BRI Enterprise GSM Indicators The CH1 and CH2 indicators signal statuses of the respective GSM modules Whenever the 2N BRI Enterprise is started detection of the GSM modules and SIM cards is carried out This process is signalled by a red LED which goes on a few seconds after voltage is supplied The GSM module detection takes a few seconds In case a GSM module or SIM card is absent the red LED keeps s
51. ing stats sets the day in a month on which the statistic data on Max number of called minutes and SMS messages number are deleted This parameter is ignored if 0 is selected By setting this parameter to value 32 enables dayly deleting of statistics after midnight SMS at no answer Default delay before send SMS s time interval of timeout for sending SMS when the called party in GSM network doesn t answer the call Value 0 disables SMS at no answer function The timeout starts after receiving of ALERTING message Text for SMS at no answer enter text that will be send when the called party in GSM network doesn t answer the call The string N is replaced by the CLIP of SIM card GSM calls statistics settings Number of seconds after connect the length of the first pulse after which pulses are counted according to the value included in the Number of seconds for next counting parameter 73 2N BRI Enterprise e Nr of seconds for next counting the number of seconds per pulse after the timeout defined in the Number of seconds after connect parameter Example If from the viewpoint of the GSM provider a call shorter than 60s is billed as a 60s call set the Number of seconds after connect at 60s If the GSM provider bills calls in seconds after the first 60s set the Number of seconds for next counting at 1 s 8 10 4 Roaming e Roaming enabled for network an international identifica
52. is manual is very much detailed and includes subsections that are irrelevant for the basic installation purposes as well as subsections referring to other BRI GSM gateway models m Packing List Please check your 2N BRI Enterprise delivery for compliance with the following packing list 2N BRI Enterprise check the model type according to the order number see the type label on the gateway back side Mains adapter according to type USB cable ISDN 4 wire RJ 45 cable Antenna Wall mounting holder Dowels Screws This manual Warranty certificate Compliance certificate 2N product CD none for rack version according to the number of GSM modules m Contents SECTION 1 PRODUCT PRESENTATION eessssssesesoscssescsosossesoesesososossesee 1 ld PULPOSC zabal sakra lava las nasa AAA wily ae alah clasts ak has NE 2 1 2 How to Cut Telephone Costs 4s cis ess et ete Sr eee tx eR Rr kaiku REE 2 1 3 Other Advantages and Applications eese 3 RF Radiation Safety PrecautiOns eee TUS ox RAM e PATRES eod doen d 4 SECTION 2 INSTALLATION cioe nid iscecseE i reos epe vaepe tee ee etude 5 220 PNE 610 0 RR aute donne O dues 6 22 Boer nstallation Guide 55s Aa boa kod att tet a ee aies 7 23 Proper NIGUHLETO ooo croire o o te ono ooo ooo oo ooo 9 2AN P DELA Connection aede goa ee oo 11 2 Antenna C ONIN CEL Soon ARR eedem M a ae 12 20 Gateway Power Supply ooo de
53. ject in case the CLIP is included in the CallBack table a CallBack is made The GSM gateway rejects the incoming call and makes an automatic CallBack CallBack after ring Ignore in case the CLIP is included in the CallBack chart a CallBack is made The incoming call is ignored If the calling subscriber does not hang up within the defined timeout default 10s the CallBack function is ignored and the call is processed normally refer to Subs 1 5 77 2N BRI Enterprise 8 11 2 DISA DTMF digits e Minimum digits in DTMF the minimum number of digits required by the gateway in the DTMF e Maximum digits in DTMF the maximum number of digits accepted by the gateway in the DTMF e Timeout while inputing DTMF digitst s a timeout during which the GSM gateway waits for the first another DTMF digit If O is selected the incoming call is connected automatically to the numbers included in the List of called numbers 8 11 3 CLIP e Replace by expression the character from the CLIP is replaced with a sequence of digits included in this field Example Calling party identification CLIP is 420602123456 a Replace by expression empty CLIP sent to the PBX is 420602123456 b Replace by expression CLIP sent to the PBX is 420602123456 c Replace by expression 00 CLIP sent to the PBX is 00420602123456 8 11 4 List of called numbers The
54. k req SIM card requires PUK undef This position of SIM card wasn t checked by gateway GSM Layer 3 Status Messages ID Name Description O0 NULL Rest status ready for call 1 CINIT Call request to GSM from Layer 4 3 OPROC Call to GSM is connected 4 CDELIV Call to GSM is ringing 6 CPRES Call indication from GSM from Layer 2 7 CRECV Call from GSM is ringing on ISDN interface 9 IPROC Call from GSM is processed by ISDN interface 10 ACTIVE Connected call 11 DISREQ Disconnection request to Layer 2 12 DISIND Indication of disconnection from Layer 2 19 RELREQ Module release for another call to Layer 2 25 OVRECV Reading of DTMF dialling from GSM from Layer 2 38 RELIND Indication of module release from Layer2 97 2N BRI Enterprise Layer 4 Status Messages ID Name Description 0 NULL Rest status ready for call 1 MORE Call request received from GSM or ISDN awaiting further dialling or timeout 2 SETUP Call request sent to opposite interface 3 PROC Call request confirmed awaiting call answer 4 ACTIVE Connected call 5 DISC Call disconnection in progress 98 Command Shell Statuses Command Line Status Messages ID Name Description 0 IDLE Rest status awaiting AT commands 1 REQUEST Communication with GSM module upon AT amp G command is displayed 2 REPORT Active tracing 3 LOGFILE Content of log file is being written out 4 CALL
55. ll relevant restrictions and regulations regarding mobile phones apply to them here SECTION 2 Installation Here is a survey of what you will find in this section Get Started Brief Installation Guide e Proper Mounting PC or LAN Connection Antenna Connection 2N BRI Enterprise Gateway Power Supply SIM Gard Installation Removal NT and TE Connection Status Indicators e Lithium Battery Replacement e Fuse Replacement 1 k According to order number 2 1 Get Started Before you start installing your 2N BRI Enterprise gateway get familiar with its physical structure arrangement of connectors and status indicators see Fig 1 Fig 2 and Fig 12 LED status indicators he ISDN TE Port ISDN NT Port 10 100 BaseT Twisted Pair Ethernet optional Fig 1 Bottom View Antenna connectors SMA female Zl ge f s C HY mO m aM gt J p gt lt Pa SIM card slots RESET button Fig 2 Top View 2 2 Brief Installation Guide e Proper mounting 2N BRI Enterprise is designed for suspension on a vertical surface Fit the holder included in the delivery on a wall and hang the gateway on it For details on the prescribed working position and other recommendations refer to Subs 2 3 e Cable connection connect the gateway using ISDN cable to your ISDN PBX or any other ISDN terminals For more details on proper wiring refer to Subs 2 4
56. llowing options are available e Reject incoming calls all incoming calls are rejected e Ignore incoming calls incoming calls are not routed to extensions The call request is either rejected or ignored the calling party hears the ringing tone on the GSM network side e CallBack this function helps establish connection on the account of the SIM card inserted in the GSM gateway The incoming call is either ignored or rejected After the calling subscriber hangs up the GSM gateway establishes connection to the defined extension When the extension answers the GSM gateway replays the CallBack message to the extension while establishing a connection to the previously calling subscriber in the GSM network After the CallBack message the GSM gateway interconnects the call e If neither of the above mentioned options is selected the AutoCLIP routing table is checked If the calling number is found the call is routed to the extension whose number is assigned to the calling number in the table not available yet 34 e In case the calling number is not included in the AutoCLIP routing chart or the AutoCLIP routing function is disabled the gateway receives the incoming call and either replays a voice message or transmits the dial tone to the calling party Then the gateway awaits the count of digits necessary for call establishing To define the minimum and maximum counts of DTMF digits use the GSM incoming groups menu
57. luded on the first line of the LCR table prefix list If no match is found the following line is used for comparison 32 If the prefix matches a LCR prefix the call time is checked for match with the routing rule on the line Again if no match is found the following LCR table line is searched In case the prefix and call time comply with the routing rules the call is routed according to the first routing rule included in Groups and GSM outgoing callss to the module corresponding to the particular GSM outgoing calls If the selected GSM module is busy or has an insufficient credit the preceding step is repeated for the following line of the LCR table section If there is no record the next LCR table line is searched In case the selected GSM module is free and has a sufficiently high credit the GSM gateway starts dialling a GSM number If the calling subscriber number has an unknown prefix or all routes are busy the GSM gateway rejects the call request An outgoing call is not billed until the called party answers the call The GSM network signals the off hook and the GSM gateway transfers this information to the PBX 33 2N BRI Enterprise 5 5 Routing of Incoming GSM Calls Incoming calls from the GSM network are subject to the algorithm described in Chyba Nenalezen zdroj odkazu and the following steps Incoming calls are processed according to the Mode parameter in the GSM incoming calls chart The fo
58. n 68 8 9 1 Number of figits dialed from ISDN e Min numbers from ISDN minimal count of digits recieved on ISDN inteface needed for establishing of the call to the GSM network If the count of digits is lower than the value in this field the connection to the GSM network will not proceed e Max numbers from ISDN maximal count of digits received on ISDN interface that will be accepted for establishing of the connection to the GSM network If the count of digits is higher than the value in this field the connection to the GSM network will continue using first n digits where n is the value in this field Wait for next digit s a timeout during which the GSM gateway waits for another digit of the subscriber dialling After this timeout if the count of received digits is sufficient the gateway tries to make connection 8 9 2 SIM cards PIN code number e SIM cards PIN number enter the PIN code to be entered automatically for new SIM cards The PIN codes of all inserted SIM cards must be same 8 9 3 GSM Module selection There is possible to set the way of GSM modules to B channels assignments for outgoing calls in this section Use the menu to choose one of the following possibilities e Cyclic GSM modules alternate after each call e Locked outgoing calls on B1 channel are routed through GSM1 module and outgoing calls on B2 channel are routed through GSM2 module e Smart calls are routed
59. n using a USB port connected as a virtual COM port To set communication select the following parameters Transmission rate 921600 bps Data bits 8 Parity none Stop bits 1 Flow control none 9 3 LAN Communication Settings To communicate with the 2N BRI Enterprise gateway through the LAN set the LAN IP address first To do this you need a direct USB PC connection You can use such programs as HyperTerminal Putty etc for communication IP address gateway address set by you Port 29 The gateway requires username USER and password PASSWORD for login The gateway responses with OK message after the entering of correct identification data 9 4 Terminal Communication The terminal is also part of the GSM configuration software To start the terminal use Functions Other functions Terminal from the main menu Be sure to configure the GSM program properly for communication refer to Subs 1 3 Functions 86 9 5 GSM Gateway Behaviour The gateway behaves like an ANSI terminal with an echo The commands are entered in the text format and the X modem protocol is used for file transfer The gateway responses with the OK message after the login to the gateway If not type at and press ENTER key In case the gateway is correctly connected the gateway responses by the OK message There is possible to set username and password to ensure better security of the gateway The gateway respo
60. n TE mode NT O Netwrok termination mode with activated internal ISDN clock generator TE E as TE mode with DTMF receiving extension TE T as TE mode without DTMF receiving trunk tei mtp 0 63 0 fixed tei ptp teimtp 64 0 dynamic tei ptp tei mtp 64 1 fixed tei mtp cause codes for failed calls cl dial timeout TIMEOUT 120 c2 dis prefix REJECT 21 c3 req mod grp not ready TEMPFAIL 41 c4 pref grps not ready CONGEST 42 89 2N BRI Enterprise 106 sack proc prog ale 107 opx npx 108 dial ring disc 109 day bits enb 1127 msn GSM Groups settings G02 mode atms afms G05 delay G06 mmdd mmdd G07 mmdd mmdd G08 delay min max tout G09 bits dial ring G101 0ld new prog elem O off 1 8 for isdn message list of old new prefixes max 47 chars dial 0 off 1 255 dialtone to NT on empty SETUP ring O off 1 255 ringtone to NT if no PROGRESS from PSTN 1 EU dial constantly 425Hz ring 1000 4000msec 425Hz 2 CZ dial 300 300 600 1200msec 425Hz ring 1000 4000msec 425Hz 3 HU dial constantly 425Hz ring 1000 4000msec 425Hz 4 GB dial constantly 425Hz ring 400 200 400 2000msec 400 450Hz disc O off 1 255 busytone to NT interface on DISCONNEECT day 0 off 1 31 of clearing bri stat ctrl bits bO not defined b1 not defined b2 subaddr recv b4 don t send CONNECT_ACK in TE mode enblock digits O overlap 1
61. nd SMS message via GSM group 1 8 Possible answers smserr busy write or smsout Messages from BRI ISDN Gateway SMS message was received and saved into SIM card Ch GSM module number 0 31 k index number of saved SMS 0 255 Sts SMS status SMS status confirmation was received and saved to SIM card this message is only for GSM modules TC35 and GM47 SMS message was sent and was not saved into SIM card Ref Ieference number of sent SMS 0 255 will be used in SMS status confirmation message content of SMS message or status confirmation Len SMS length number of bytes in PDU Pdu message content in PDU format Csum Checksum of all PDU bytes 2 hexa digits calculated without carry SMS message or status confirmation was deleted from position ix response to error command Reg fequired GSM module or GSM group Err error code 6 busy 40 write 41 read 42 delete 43 list 95 2N BRI Enterprise Status Messages ISDN Layer 1 Status Messages ID Name Description 0 DEACT Deactivation no signal received 1 ACTIVE Activation full synchronisation achieved frame multiframe crc 2 SIGNAL Signal received no synchronisation 3 SYNC Signal received only partial synchronisation frame ISDN Layer 2 Status Messages ID Name Name according to ITU T Q 921 O NOTEI TEI Unassigned 1 AWTEI Assigned Awaiting TEI 2 AWTEST Establish Awaiting TE
62. ndow with some essential data necessary for the gateway identification see Fig 29 Enter the gateway name chosen by you into the Gateway name item In case that gateway has activated secure access it is recommended to complete the Gateway address Username and Password Eventually complete the File of gateway parameters including the directory path and filename Gateway name Login Password File of gateway parameters config program 2N HG 2N H ini mul NI Fig 29 Gateway Editing Window 46 Edit used for editing identification data on the gateway entered To edit the data select the required gateway from the list of used gateways and click on Edit Remove used for removing a gateway from the list of gateways Remove all used for removing ALL gateways from the list Select click on this button to select a GSM gateway and whose parameters can be set after Close is pressed Default by clicking on this button you start working with the default parameters Connect used for closing the Gateway selection window and opening the gateway configuration window 7 3 Configuration Program Basic Menu The following items are available in the main configuration program menu File for physical work with the configuration file default configuration and templates Gateway contains items for connect and disconnect with gateway Also contains item Gateway list Gateway cont
63. nication technologies The Intelligent Routing of Incoming Calls function also including AUTO CLIP Routing function accelerates connecting of incoming calls and makes calling more comfortable The DISA function with an easily recordable welcome message is available Unlike mobile telephones this system does not expose you to the RF electromagnetic field while making calls Password for configuration of the gateway on all ports CLIP and CLIR for incoming calls from GSM network ENBLOC OVERLAP mode of sending called number to ISDN network Sending of SMS messages in case of missed call on GSM network side Remote GSM control for easy controlling your GSM gateway 2N BRI Enterprise RF Radiation Safety Precautions It is prohibited to use any transmitters including GSM gateways in areas where explosives are used such as quarries It is forbidden to use mobile phones and thus GSM gateways too at refuelling points A GSM gateway may affect sensitive life saving devices in medical centres So it is prohibited to use mobile phones and GSM gateways here In general any restriction regarding mobile phones based on RF energy radiation applies to GSM gateways Where necessary a GSM gateway may be installed at a safe distance in the neighbouring building e g and a BRI ISDN connection cable may be carried from the GSM gateway to the original building Although GSM gateways are not intended for aircraft or cars a
64. nses with the message shown in the Fig 44 if the login name is required After entering of your login name press lt ENTER gt and after that enter the password M114 B 02 50 BRI114 V 02 04 07 BE Date time 21 7 2002 19 13 06 03 SNumber M113 11260003 BE login Fig 44 Login message 9 6 List of Terminal AT Commands All commands start with AT by default Note Some of the below mentioned AT commands may not be available in the current firmware versions Note AT commands are same as for BRI Enterprise gateway Commands which contains BRII Pxx settings are not used in 2N BRI Enterprise gateway 2N BRI Enterprise gateways has only BRI2 Exx interface Basic AT Commands AJ Iepeat last command without AT I3 copyright amp firmware I4 serial number amp FRES factory defaults amp reset amp V view active parameters system amp VI View active parameters isdn amp V0 View active parameters common KVK view active parameters modules 1 2 amp V9 view active parameters inc groups amp VALL view all group parameters amp P View pseudo params amp N View network params net 1 8 amp NALL view all network params amp A View autorouting table lt SPACE continue gt 87 2N BRI Enterprise XR amp T amp TMOD amp G atcommand amp G xtcommand amp G cmd amp GALL cmd amp S ASH amp S info KOH amp QALL amp L amp
65. nsmission protocol DISA Voice File Parameters Sound format Wav Sampling frequency 8 kHz Count of channels 1 mono Codec ISDN A law Tab 4 DISA Message File Parameters 36 SECTION 2 Ethernet port configuration This chapter focuses on installation and configuration of Ethernet port for communication over 10 100BaseT computer network This port is optional part of the gateway It is possible to skip this chapter if your gateway is not equipped with this port This section includes e Default connection settings e Installation of Ethernet port drivers e Ethernet port configuration e Default connection settings This chapter is intended for BRI Enterprise Gateway with 10 BASE T port Twisted Pair Ethernet 37 2N BRI Enterprise 6 1 Default connection settings Default gateway IP parameters IP address 10 1 10 100 Port 1001 Warming There is no password protection Before installation please activate it by configuration tool section 3 3 3 page 47 6 2 Installation of Ethernet port drivers Run SETUP EXE to start the installation program Click the Next button after the opening of the Welcome window See Fig 21 InstallShield Wizard xj Welcome to the InstallShield Wizard for Tibbo Device Server Toolkit The InstallShield Wizard will install Tibbo Device Server Toolkit on your computer To continue click Next lt Back Cancel Fig 21 Ethernet
66. nterface Start tracing of LAN amp Telnet on layer x x 2 Layers IP TCP Telnet x 3 Layers TCP Telnet x 4 Layer Telnet Start tracing of ISDN BRI 8 GSM on layer x x 1 Layers 1 2 3 4 x 2 Layers 2 3 4 x 3 Layers 3 4 x 4 Layer 4 Start tracing AT R2 to COM interface Stop tracing AT R2 to COM interface 93 2N BRI Enterprise 94 Work with SMS AT G A6 AT G 55 AT SX ch AT SR ch ix AT SDzch ix AT SMzch len pdu csum AT SG grp len pdu csum smsinc ch ix sts smsrep ch ix smsout ch ix ref smspdu ch ix sts len pdu csum smsdel ch ix smserr ch ix req err SMS sending and receiving commands Start low level controlling for SMS can run only on one port Stop low level controlling on used port Control SMS sms listing request to list all SMS messages and status confirmations saved on SIM card Possible answers smserr busy list or smsinc ix 1 255 for each saved SMS or status SMS messages end of list or empty SIM card smsinc ix 0 sms read request to read SMS or status SMS saved in SIM card Possible answers smserr busy read or smspdu sms delete request to delete SMS message or status SMS message Possible answers smserr busy delete or smsdel sms to module request to send message via GSM module 0 31 or via any GSM module ch 32 Possible answers smserr busy write or smsout sms to group request to se
67. on RACH channel in dBm or current power level RXLev Minimal receiving level in dBm to allow registration C1 Coecifient for base station selection TS Timeslot number timAdv Timing advance in bits Q Receiving quality 0 7 53 2N BRI Enterprise Test calls for make test calls for check voice qualitz or right configuration Test calls can be outgoing to GSM or ISDN interface or incoming In case of proceeding call the gateway automativally generates trace which you can save for possible check in case of problems Online commands for sending AT command directly to selected GSM module Show dynamic CLIP routing table downloads actual records of Dynamic CLIP routing function Load parameters fro gateway downloads configuration of the gateway from the gateway to the configuration program Save parameters to the gateway uploads configuration parameters form the program to the gateway Gateway reset resets the gateway Factory parameters reset restarts the gateway with company settings 7 3 4 Setting This menu is available under 54 Settings Help Language gt y English Czech 3 dar c Aim ti Communication setting helps set the type of communication of the 2N BRI Enterprise configuration software By clicking on this item you open a configuration window see Fig 33 You can use a USB cable or remote GSM CSD for communication with the GSM gateway
68. onsidered if the count is not included in the prefix table 8 13 LCR table The LCR Least Cost Routing table helps define the call routing procedure according to the called subscriber s number depending on the day time and day in a week The LCR table setting using the GSM configuration software is discussed in this subsection Network Using time Groups Limit Add Edit Remove Remove all Load from the gate Save to the gate Save to file dl I 3 Defaut Holiday list V 0 00 24 00 3 0 Date to move to summer time dd mm ono Date to move to winter time dd mm fono Add Remove Remove all Default Fig 42 LCR table LCR Table e Add this button adds a record into the LCR table By pressing it you open the editing window see Fig 43 81 2N BRI Enterprise Edit LCR entry Prefixes M Time limitation of use gt GSM module 2 v From jw Usage during weekends holidays C Use whole weekend Use the above set time Maximum length of call 0 off jo Prefislist 1 23001 Destinations GSM module 1 v 00 00 To 24 00 Cancel Fig 43 LCR table Data Entering By completing the LCR data adding table you set one call routing rule 82 e Prefix list select one of the prefixlists from the GSM Parameters Prefixes in the pull down menu to which the routing rule should apply The prefixlist settings are dis
69. oor use It may not be exposed to rain flowing water condensed moisture fog or mist The gateway may not be exposed to aggressive gas acid vapours solvents etc or aggressive liquids during cover cleaning for example The GSM gateway is not designed for high vibration environments e g means of transport machine rooms etc Free space has to be left under and over the gateway for cables and agitated air to remove operational heat Install the gateway on a place with a good GSM signal A misplacement of the GSM gateway or its antenna near television broadcasting or similar RF sensitive devices may evoke an adverse effect upon their function Being a source of RF energy emission the gateway antenna should not be located close to human bodies The hazard is higher than with mobile telephones because the gateway is usually used by many people and thus employed more often 2 4 PC or LAN Connection The 2N BRI Enterprise can be connected to a PC using a USB cable terminated with a USB B connector A direct connection of 2N BRI Enterprise and a PC is necessary for the initial gateway configuration The gateway USB port default parameters are 921 600 bps 8 data bits no parity 1 stop bit no flow control Set the same parameters for the communication program on the PC side 2N BRI Enterprise can be connected to the 10 100BASE T Twisted Pair Ethernet LAN using a standard straight through cable terminated with a
70. port transfer of additional informations about in CLIP field 79 2N BRI Enterprise 8 12 Prefixes Prefislist 1 Prefisist 2 Prefislist 3 Prefislist 4 Prefislist 5 Prefislist 6 Prefixlist 7 Prefixlist 8 Table of replaced prefixes Add Remove Network ID Default count of digits complete dialed number Edit Remove all if Table of prefixes Prefix change for call from NT to TE Add Edit Remove Remove all eoo 1 Add Edit 5 i Remove Remove all CD CO 7 CD Cl 4 CO P9 CS Fig 41 Network List Editing Window The List of prefixes helps the gateway connect calls to various GSM networks You can define call routing by prefixes in eight groups Default sets the current list to default settings Default all sets all prefixlists to default setting You will find the following items in the editing window 80 Table of replaced prefixes a table of prefixes to be replaced e g 420 with 0 This change is made before the prefix table is checked Table of prefixes a table of called prefixes You can define the dialling length too here If you do not enter the dialling length the Default count of digits will be used automatically GSM network ID a numerical identification code of the selected prefix table used for internal identification purposes only It has no influence on call routing Default count of digits used for defining the count of digits to be c
71. program the DISA voice message into the gateway e Record DISA using configuration program e Record the voice message from GSM telephone e Record DISA into your PC and save the wav file into your gateway using the XMODEM protocol and defined AT commands 35 2N BRI Enterprise DISA Message Recording using terminal and GSM phone Recording of DISA message Open terminal window see Subs 5 e Establish connection with your GSM phone using AT command at sg0 phone_number_of_your_GSM_phone e Accept incoming call from your GSM gateway by GSM phone CLIP of SIM card plugged in SIM card holder 1 e Enter AT command at m record in terminal window which results in recording of DISA message 60 s max e To stop recording of DISA message press ENTER e Finish the phone call by hanging up or entering of AT command at d Erasing of DISA Message To get an information on recorded DISA Message enter AT command at m status To erase DISA message enter AT command at m erase in terminal window Recording of DISA Message using terminal and PC Recording the voice message into your PC keep the maximum length of 65 s compression according to the ISDN A law codec mono sampling frequency of 8 kHz The voice message recording program is part of your GSM gateway software delivery Summary of parameters the file must meet is in table Tab 4 below Name the file Disa wav and upload it to 2N BRI Enterprise using a terminal and the XMODEM tra
72. r adapter cable first The location of the fuse on the main board is on the Fig 13 Open the cover remove the faulty fuse and check it Replace the fuse by a fuse of the same type only Close the cover and reconnect the power adapter cable 20 SECTION 3 ISDN BRI Extension Configuration To configure your 2N BRI Enterprise properly you have to know the type of connection of your ISDN terminals This section helps you install your GSM gateway between already interconnected ISDN terminals For information on the ISDN type refer to your ISDN provider s registration form or check with your telephone network administrator This section includes e Point to Point Connection e Point to Multipoint Connection 21 2N BRI Enterprise 3 1 Point to Point Connection The Point to Point EuroISDN with DDI configuration interconnects directly one ISDN terminal TE with a network terminal NT see Fig 14 This type is applied mainly where PBXs are connected to the ISDN c 3 2 Point to Multipoint Connection Point to Multipoint EuroISDN with MSN is another type of ISDN terminal interconnection Here the network terminal NT is interconnected with up to eight ISDN terminals through a 4 wire passive bus as shown in Fig 15 Private network Fig 14 Point to Point Connection Private network 8 ISDN terminals max ta Fig 15 Point to Multipoint Connection 22
73. rations is used for loading configuration template e Closet terminates the configuration program work 7 3 2 Gateway e Connect is used for establishing connection with the gateway e Disconnect is used for disconnecting from connected gateway e Gateway list is an item selecting the gateway to be configured An introductory window gets displayed after you click on this item Subs 1 2 48 7 3 3 Gateway control This menu is available under Gateway control Settings Help Login account Date time Firmware Licence Tracing Terminal LOG File Call data records Statistics Diagnostics Info about actual calls CDR buffer state Connection state GSM monitor info Test calls Online commands Show dynamic CLIP routing table Fig 30 Gateway control Item of Main Menu e Login account item for change access username and password of the gateway e Date Time gateway date and time settings You can synchronise the time data with your PC e Firmware Licence offers two windows The Firmware window displays and helps upload the latest firmware version To find the GSM gateway firmware version press the Load from the gate which downloads information on the firmware and bootware versions from the GSM gateway 49 2N BRI Enterprise Firmware Firmware version Bootware version Firmware file E Load from the gate Upgrade firmware To upload firmwa
74. re Establish communication with the gateway Click on the button and find the firmware file in your PC directory in the format of P2009 V hex Press Open to get the file ready for uploading into the 2N 2N BRI Enterprise Uparade firmware Click on to start the firmware uploading procedure The program starts uploading the firmware automatically The gateway is in the reset mode during the process Do not interrupt the firmware uploading process to avoid firmware damage and gateway failure Should the firmware uploading process get interrupted reset the ISDN GSM gateway and try to upload the firmware again CAUTION Make sure that what you are going to upload is the original and undamaged file with the latest firmware version as available at our websites www 2n cz The License window helps to licence the GSM gateway To identify the GSM gateway status click on Load from the gate If you require additional license please contact your sales person 50 Information for gateway licence Enabled protocols Gateway limitation Load from the gate Licence status Networks Gateway unlock Licence key for gateway Set gateway licence Enter the received licence into Enter license and press Enter license button Click on Load from the gate to know whether the license has been accepted successfully CAUTION By inserting an invalid license you may disable the GSM gateway functionality
75. rol contains the Gateway operation monitoring functions Firmware Licence and Date and time specifications and functions for Gateway reset and uploading of Factory settings All functions located in this sections requests on line connected gateway Settings menu items for Gateway selection gateway Communication settings and Language setting of the configuration software Help information on the About application of the configuration software together with contacts to the technical support personnel 47 2N BRI Enterprise 7 3 1 File This menu 1s accessible under T BRI config program File Gateway Gateway control Settin e Load is used for loading of the Load F3 i configuration file of the selected Save F2 ateway to th nfiguration gateway ito P i Load from disk Alt F3 program Save as Alt F2 e Save is used for saving of the rera sting configuration to the configuration Default configurations file of the selected gataway Close Alt x mr CUT To enn wars YY rr e Load is used for loading an external file to the configuration program Structure of this file is same as of configuration file which was selected on gateway selection procedure but he content is different e Save as is used for saving of configuration to an external file than the one selected on gateway selection procedure e Default settings is used for loading default configuration e Default configu
76. s koutky 38 64 Default Connection Settings s ee et tah B BRA ATIS ya 40 SECTION 6 INTRODUCTION OF CONFIGURATION PROGRAM41 7 1 2N BRI config program Installation 42 7 2 Running of BRECOH IS DEOSFAITI ctt ce De D Ht RE 42 7 3 Configuration Program Basic Menu ee eec eite 45 TA Button Basse e ete en ea a been o ee 54 7 5 Topic Last and Alphabetical Grlossaty eee onte ens 54 SECTION 7 CONFIGURATION iciccccccosesscssesesesnsosesestonnsosenssvonsossasasesesnsesesoossens 56 SECTION 9 CONFIGURATION USING TERMINAL 81 SECTION 9 TECHNICAL PARAMETERS 4 e eenttnn 100 2N BRI Enterprise SECTION 1 Product Presentation Here is a survey of what you will find in this section e Purpose How to Cut Telephone Costs Other Advantages and Applications e RF Radiation Safety Precautions 2N BRI Enterprise 1 1 Purpose The 2N BRI Enterprise helps interconnect the ISDN and GSM networks It can also be applied in direct ISDN PBX GSM connections in combination with an ISDN telephone set analog telephone set or a coin operated telephone connected through a terminal adapter etc The voice mode i e an outgoing or incoming call is the basic function of the system The gateway is equipped with all functions necessary for such use and provides a very high comfort in this mode In addition to voice transmission 2N BRI Enterprise can send and receive short text mess
77. select a installed and select a virtual COM port for your PC gateway connection Establish communication between your PC and the gateway refer to Subs 8 1 2N BRI Enterprise configuration now use the configuration software to set all necessary gateway parameters ISDN parameters basic GSM parameters and tariff metering pricing parameters routing restrictions rates system parameters and input and switch properties Having set the required parameters upload the configuration data to the gateway via a USB For more details on the configuration software see Section 8 according to the order number 2 3 Proper Mounting e The 2N BRI Enterprise is designed for mounting on a vertical surface For this purpose a wall mounting holder is available Just fit the holder with dowels and screws Fig 3 to the wall and hang the gateway as shown in Fig 4 Fig 4 Gateway Hanging e It is possible to operate the GSM gateway in another working position e g on a desk for a short time only for example in servicing centres for quick testing purposes The allowed working temperature and relative humidity ranges are included in Section 10 2N BRI Enterprise 10 Exceeding the recommended operating temperature values need not affect the gateway function immediately but may result in more rapid ageing and lower reliability The gateway is intended for ind
78. table you achieve even more remarkable cuts To make call routing to external ports based on prefixes and the LCR table work properly enter the GSM provider prefix and the count of prefix following digits into the GSM destination table The ISDN GSM gateway also allows you to route outgoing GSM calls on the basis of the SIM card position In this case outgoing calls are not routed according to the GSM provider s number but through the defined GSM module In addition the ISDN ports can work in the pass through mode This means that all calls are routed to the respective complementary port without any check Namely from TE to NT and vice versa 5 4 Routing of Outgoing GSM Calls If the GSM gateway is connected to your PBX internal line enable the DISA function to the GSM network to make your GSM gateway answer every call routed to it by the PBX and wait for further dialling to GSM networks Routing of outgoing calls via the GSM gateway proceeds as follows e The calling subscriber dials a number e The GSM gateway waits for further digits to be dialled This timeout results in a certain delay between the subscriber s dialling and the subsequent dialling by the GSM gateway Therefore select the Default count of digits for called destinations while configuring your GSM gateway Then the GSM gateway initiates the outgoing call processing algorithm on receiving the last digit e The dialling prefix is first checked with the prefixes inc
79. tart of system unknown cause Watchdog Restart of system by watchdog BKPT code CPU error break code detected Stack error CPU error stock integrity failure Divided by zero CPU error dividing by zero RETI code CPU error illegal using of instruction reti NMI intr CPU error wrong interrupt VOID intr CPU error wrong interrupt Upgrade reset Start of upgrade firmware procedure Software reset Reset by AT commands at amp fres INIT Eeprom Initialisation of eeprom configuration Flash Initialisation of flash memory firmware HW ERR address of chip RD read value WR expected value Duart RD WR Error in initialisation of serial controller on GSM board SYSERR User stack error SW error stock integrity failure BRDIN 08 TYP STS the board inserted number of gsm board type status BRDOUT 08 TYP STS the board disconnected BRDRES 08 TYP STS Reset the board by AT command ALL GSM RESET CMD Reset of all GSM boards by AT command SYSTEM RESET CMD Reset of system by command at amp bsys L1 ERR reserved L2 ERR Error of 2 ISDN layer by Q 921 A unsol RX F Received packed RR RNR REJ with unexpected bit F 1 B unsol DM F Received packed DM with unexpected bit F 1 C unsol UA F Received packed UA with unexpected bit F 1 D unsol UA Received packed UA with unexpected bit F 0 E unsol DM Received packed DM with unexpected bit F 0 F peer re est Received packed SABME in status OKEST G repeated SABME Rep
80. tes are on the side closer to the GSM gateway antenna connectors Having inserted the SIM card push the card gently until you hear a click signalling that the card has been snapped by the push pull holders Secure the SIM card by shifting the latch to the right in order to avoid incidental removal of the SIM card To remove the SIM card take the opposite steps You can replace a SIM card even with the gateway on M f x 2 L cH C 9M 1 A SUP se E A sE t i E Fig 7 SIM Card Inserting Procedure In case of SIM card replace is necessary to make restart of GSM module or whole gateway 2 8 NT and TE Connection ISDN terminals are connected to the NT and TE connectors depending on the configuration of your telecommunication equipment They are connected using a 4 wire passive bus through RJ 45 connectors For NT or TE connections see Fig 9 and Fig 10 The RJ 45 pins for TE and NT are shown in Fig 8 14 4 _ 5 4 5 3 6 1 nepou it 3 6 1 nepou it 2 7 2 nepou it 2 7 2 nepou it 3 Tx 3 Rx 1 8 1 i me 3m 5 Rx 5 Tx 6 Tx 6 Rx 7 nepou it 7 nepou it TE konektor 8 nepou it NT konektor 8 nepou it Fig 8 TE and NT Connector Pins T Fig 10 ISDN GSM Gateway Connected as ISDN Terminal TE 2N BRI Enterprise PBX NT BRI2 2B D ISDN eguipmnet TE
81. through the module that has less called minutes in statistics 69 2N BRI Enterprise 8 9 4 Signalling tones for calls to GSM e Dialtone to NT interface on empty SETUP this menu sets the type of dialling tone generated to the NT interface by GSM gateway on receiving SETUP message without called party number field e Ring tone in this menu is possible to select the type of ringing tone generated by the GSM gateway when calling to the GSM network 8 9 5 Relax delay Time delay between two calls to the GSM network Establishing of new call to GSM network thru the same GSM module is possible after expiry of this timeout The GSM module clears the call to GSM network during this time The optimum value is about 2 s 8 9 6 DIMF Delay Delay 1 100 s sensitivity of DTMF receiver from GSM network Parameter delay means 10 miliseconds which is added to default value 20ms The total time is minimal delay between two DTMF chars Example DTMF number 30 delay 30 10 20 320 8 9 7 SIM card number In this section is possible to define which SIM card number should be used in the GSM gateway e IMSI International Mobile Subscriber Identity e SCID SIM Card Identification Number 8 9 8 Don t send CLIP By enabling this function you deactivate transfer of calling party number CLIP from GSM to ISDN In case that this parameter will be switched off CLIP from GSM will be forwarded to ISDN supported by
82. tion code of the network for which roaming is enabled It consists of two numbers e MCC Mobile Country Code Czech Republic 230 e MNC Mobile Network Code T Mobile 01 Telefonica 02 Oskar 03 Thus the T Mobile International Identification Code is 23001 To disable roaming leave this field blank Example lt empty gt roaming restricted 2300 roaming restricted minimum is five digits 23002 roaming enabled only to network code 23002 230Xx roaming enabled to network codes from 23000 to 23099 xX001 roaming enabled with codes which has last three digits 001 XXXxX roaming enabled to ANY GSM 3G network code 74 8 10 5 8 10 6 8 10 7 8 10 8 CLIR function e CLIR This parameter defines whether or not the calling SIM card telephone number shall be displayed to the called party It is not recommended to present the telephone number of the SIM card inserted in the GSM module to the called party to avoid problems with calling back It is impossible for technical reasons to transmit telephone numbers of ISDN terminals to a GSM network One of the following parameters can be set for each GSM group e Default default settings of the GSM provider e Disable CLIP on the SIM card telephone number is transmitted to the GSM network Contact your GSM provider for activation of this service if it is not supported automatically e Enable CLIP off the SIM card t
83. ule serial no 352021001352335 Module serial no 352021001356104 ID SIM card Sim err ID SIM card Sim err Signal intensity Signal intensity BRI 1 status BRI 2 status Layer 1 DEACT Layer 1 DEACT Layer 2 NOTEI Layer 3 NOTEI TEL 0 TEL 0 Layer3 NULL Layer3 NULL Mode NT mtp Mode TE pstn Channel B1 NULL Channel B1 NULL Channel B2 NULL Channel B2 NULL Fig 32 Modules diagnostics window e Info about actual calls information on currently made calls e CDR buffer state informations about gateway s CPU and memory loads Actual status of CDR memory is named Count of call data records number of saved CDR of capacity e Connection state informations about gateway s configuration interfaces 52 e GSM monitor info downloads actual GSM network informations from selected GSM module supported only TC35i module Description of response parameters from TC35i module Chann ARFCN Absolute Frequency Channel Number of the BCCH THC carrier If chann is h BTS supports hopping during a connection Rs RSSI Received signal strength of the BCCH carrier from 0 to 63 The indicated value is composed of the measured value in dBm plus an offset This is in accordance with a formula specified in 3GPP TS05 08 PLMN PLMN ID code LAC Location area code HEX Cell Cell ID code HEX NCC PLMN color mode BCC Base station color mode PWR Maximal power level used
Download Pdf Manuals
Related Search
Related Contents
Castelle TMX 10031161 User's Manual OWNER / OPERATOR MANUAL MODE D`EMPLOI Copyright © All rights reserved.
Failed to retrieve file