Home

FX3U-4DA Installation Manual

image

Contents

1. Associated Manuals Manual name Description FX3U FX3UC Series User s Manual Analog Control Edition FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition Describes specifications for analog control and programming method for FX3U FX3UC Series PLC JY997D16701 MODEL CODE 09R619 JY997D16601 Describes PLC programming for basic applied instructions and devices MODEL CODE 09R517 Explains FX3U Series PLC specification details for I O wiring installation and maintenance JY997D16501 MODEL CODE 09R516 FX3U Series User s Manual Hardware Edition Note FX3UC Series PLC specification details for I O wiring installation and maintenance can only be found in the Japanese Manual How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Certification of UL cUL standards The following product has UL and cUL certification UL cUL File Number E95239 Models MELSEC FX3U series manufactured FX3U 4DA Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive and LVD directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsu
2. 55 2 17 _ 7 6 5 MASS Weight Approx 0 2kg 0 44 Ibs 1 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw 2 Extension cable 3 POWER LED green Lit while 5V DC power is supplied from PLC 4 Terminal block for power supply 24V DC M3 terminal screw 5 Terminal block for analog output 6 24V LED red Lit while 24V DC power is supplied properly to terminals 24 and 24 7 D A LED red Flashes at high speed during D A conversion 8 DIN rail mounting hook 9 DIN rail mounting groove 35 mm 1 38 wide 1 2 2 Terminal Layout e viej ve ve VY Left side of the product Extension cable side 2 Installation INSTALLATION PRECAUTIONS CAUTION e Use the product in the environment within the general specifications described in PLC main unit manual Hardware Edition Never use the product in areas with dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibrations or impacts or expose it to high temperature condensation or wind and rain If the product is used in such a place described above electrical shock fire malfunction damage or deterioration may be caused Do not touch the conductive parts of the product directly thus avoiding failure or malfunction Install the product securely using the DIN rail or screws Install the product on a flat surface If the mounting surface is rough undue force will be app
3. consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system afa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN
4. cable shielding should be used Ground the shield of the twisted shielded cable at one point on the signal receiving side e Please use FX3U 4DA while installed in a shielded enclosure For the details refer to the following manual Refer to the FX3U Series User s Manual Hardware Edition 1 Outline The FX3U 4DA special function block for analog output converts digital values supplied from PLC into analog values voltage current and outputs those analog values from its four output points 1 1 Incorporated Items Check if the following product and items are included in the package Product pa a PONER Manual Special unit block No label Dust proof sheet x 1 manual 1 2 External Dimensions Part Names and Terminal Layout 1 2 1 External Dimensions and Part Names Without top cover 2 3 4 80 3 15 mounting hole pitch 55 2 17 _ 7 6 5 MASS Weight Approx 0 2kg 0 44lbs 1 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw 2 Extension cable 3 POWER LED green Lit while 5V DC power is supplied from PLC 4 Terminal block for power supply 24V DC M3 terminal screw 5 Terminal block for analog output 6 24V LED red Lit while 24V DC power is supplied properly to terminals 24 and 24 7 D A LED red Flashes at high speed during D A c
5. number can be checked by monitoring D8001 as the last three digits indicate it 4 2 General Specification The items other than the following are equivalent to those of the PLC main unit For other general specifications refer to the manual of the PLC main unit Refer to the FX3U Series User s Manual Hardware Edition Item Specification 500V AC for one minute Gontorming to JEM We Dielectric withstand voltage Between all terminals and ground terminal of PLC 5MQ or more by 500V DC megger main unit 4 3 Power Supply Specification Insulation resistance Item Specification D A conversion 24V DC 10 160mA for 24V DC circuit driving power Connect a 24V DC power supply to the terminal block 5V DC 120mA CEV Arving power 5V DC power is supplied internally from the main unit 4 4 Performance Specification Description Item Voltage output 10 to 10V DC Current output 0 to 20mA 4 to 20mA DC Analog output range External load 1kQ to 1MQ External load 500 Q or less Offset 0 to 17mA Gain 3 to 30mA Digital input 15bits binary Resolution 0 32mV 20V 64000 0 63uA 20mA 32000 e 0 3 60mV for full scale of 20V when ambient 20mA when ambient temperature is 25 C 5 C temperature is 25 C 5 C 0 5 100mV for full scale e 0 5 100uA for full scale of 20V when ambient of 20mA when ambient temperature is 0 C to 55 C temperature is 0 C to 55 C e 0 3
6. 60uA for full scale of Total accuracy A D conversion time 1ms The number of selected channels will not affect this value e Output mode 0 e Output mode 2 Output voltage V Output current mA Oe asnan 209 32000 0 32000 32640 Output Digital value characteristics 4 e Output mode 3 Output current mA 20 324 ee l 20 ry I l I l I l I l I l 4 E 0 32000 32640 Digital value e The photo coupler insulates the analog output area from the PLC neulaton e The DC DC converter insulates the analog output area from the method power supply unit e Channels are not insulated from each other R 8 point Count either the input or output points of the PLC 1 Change the offset and gain values to change the output characteristics However the resolution doesn t change even when the offset and gain values change When analog value mV A specification is enabled in the output mode 1 or 4 the offset value and the gain value don t change 2 The offset and the gain should satisfy the following condition 1 V lt Gain Offset lt 10 V 3 The offset and the gain should satisfy the following condition 3 mA lt Gain Offset lt 30 mA 4 The output characteristics vary depending on the output mode to be used For the details of the output characteristics refer to the following manual Refer to the FX3U FX3UC Series User s Manual Analog Control Edition 4 5 Output characteristic
7. Side JY997D20801A B E A JAPANESE B ENGLISH Changes for the Better Aa MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEG F FX3U 4DA INSTALLATION MANUAL F X 3y This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective February 2006 Specifications are subject to change without notice 2006 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories ODANGER and ZXCAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage
8. a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective February 2006 Specifications are subject to change without notice 2006 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories KODANGER and ZXCAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Associated Manuals Manual name Description FX3U FX3UC Series User s Manual Analog Control Edition FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition Describes specifications for analog control and programming method for FX3U FX3UC Series PLC JY997D16701 MODEL CODE 09R619 JY997D16601 MODEL CODE 09R517 Describes PLC programming for basic applied instructions and devices Explains FX3U Series PLC specification details for I O wiring ins
9. ard EN61131 2 2003 Programmable controllers Equipment requirements and tests Remark Compliance with all relevant aspects of the standard e Radiated Emissions e Mains Terminal Voltage Emissions e RF immunity e Fast Transients e ESD e Surge e Conducted e Power magnetic fields Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary induced errors not exceeding 10 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed with general good EMC practice for the users complete control system users should expect normal errors as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good
10. bishi Electric sales site Requirement for Compliance with EMC directive The following products have shown compliance through direct testing of the identified standards below and design analysis through the creation of a technical construction file to the European Directive for Electromagnetic Compatibility 89 336 EEC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Models MELSEC FX3U series manufactured from February 1st 2006 FX3U 4DA Standard EN61131 2 2003 Programmable controllers Equipment requirements and tests Remark Compliance with all relevant aspects of the standard e Radiated Emissions e Mains Terminal Voltage Emissions RF immunity e Fast Transients e ESD e Surge e Conducted e Power magnetic fields Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC pro
11. connected 3 Use a 2 core twisted shield wire for analog output line and separate it from other power lines or inductive lines 4 If there is ripple or noise in the output voltage connect a capacitor of approximately 0 1 to 0 47 uF 25 V in the vicinity of the signal receiving side 5 Ground the shielded wire at one point on the signal receiving side 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 1002 or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the FX3U Series User s Manual Another Another Another Q Q O Q C Hardware Edition Shared grounding Common grounding Good condition Not allowed Independent grounding Best condition e The grounding wire size should be AWG 14 2 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specification STARTUP AND MAINTENANCE PRECAUTIONS Z CAUTION e Do not disassemble or modify the unit Doing so may cause failure malfunction or fire For repair contact your local Mitsubishi Electric distributor e Do not drop the product or do not exert strong impact doing so may cause damage DISPOSAL EATON Z CAUTION e Please contact a company certified in the disposal of electronic waste for environmentally safe re
12. ctors Contact failures may cause malfunctions 2 1 Arrangements The product connects on the right side of an PLC main unit or extension units blocks including special function units blocks For connection to FX3UC Series PLC or FX2NC Series PLC extension block FX2NC CNV IF or FX3UC 1PS 5V is required For further information of installation arrangements refer to the following manual Refer to the FX3U Series User s Manual Hardware Edition 2 2 Mounting The product is mounted by the following method e Direct mounting e DIN rail mounting 2 2 1 Direct Mounting The product can be mounted with M4 screws by using the direct mounting holes Refer to the External Dimensions section 1 2 for the product s mounting hole pitch information An interval space between each unit of 1 to 2 mm 0 04 to 0 08 is necessary For further information of direct installation also refer to the following manual Refer to the FX3U Series User s Manual Hardware Edition 2 2 2 DIN Rail Mounting The product can be mounted on a DIN rail DIN46227 35mm width 1 Fit the upper edge of the DIN rail mounting groove right fig A onto the DIN rail 2 Press the product against the DIN rail 3 Connect the extension cable right fig B to the main unit input output extension unit block and special function unit block on the left For the details of the extension cable con nection refer to the following manual Refer t
13. cycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS CAUTION e During transportation avoid any impact as the product is a precision instrument Check the operation of the product after transportation 4 1 Applicable PLC Model name FX3U Series PLC Applicability Ver 2 20 from the first product and later Ver 1 30 from the product manufactured in August 2004 with FX3UC Series PLC SER No 480000 and later The version number can be checked by monitoring D8001 as the last three digits indicate it 4 2 General Specification The items other than the following are equivalent to those of the PLC main unit For other general specifications refer to the manual of the PLC main unit Refer to the FX3U Series User s Manual Hardware Edition Item Specification 500V AC for one minute Contorming toveMe 102 Dielectric withstand voltage Between all terminals and ground terminal of PLC 5MQ or more by 500V DC megger main unit 4 3 Power Supply Specification Insulation resistance Item Specification D A conversion 24V DC 10 160mA for 24V DC circuit driving power Connect a 24V DC power supply to the terminal block 5V DC 120mA CRU driving power 5V DC power is supplied internally from the main unit 4 4 Performance Specification Description Voltage output Current output Analog output 10 to 10V DC 0 to 20mA 4 to 20mA DC range External
14. e accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN side JY997D20801A B E A JAPANESE B ENGLISH a MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEGIF FX3U 4DA INSTALLATION MANUAL F X 32u Changes for the Better This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in
15. e gain value don t change 2 The offset and the gain should satisfy the following condition 1 V lt Gain Offset lt 10 V 3 The offset and the gain should satisfy the following condition 3 mA lt Gain Offset lt 30 mA 4 The output characteristics vary depending on the output mode to be used For the details of the output characteristics refer to the following manual Refer to the FX3U FX3UC Series User s Manual Analog Control Edition 4 5 Output characteristics The output characteristics in each output mode are as follows Output Digital input Output mode Analog output mode range range 0 Voltage output mode 10 to 10V 32000 to 32000 1 Voltage output analog value 19 9 40V_ 10000 to 10000 mV specification mode 2 Current output mode 0 to 20mA 0 to 32000 3 Current output mode 4 to 20mA 0 to 32000 0 to 20000 4 Current output analog value 0 to 20mA uA specification mode This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damag
16. k or damage to the product Termination of the wire should follow the dimensions described in this manual Tightening torque should be 0 5 to 0 8 Nem 3 1 Applicable Cable and Terminal Tightening Torque The size of the terminal screws is M3 The end disposal of the cable shows below Tighten the terminal to a torque of 0 5N m to 0 8N m e When one wire is connected to one terminal 3 2 0 13 Terminal Crimp 6 2 mm 0 24 screw terminal or less 3 2 0 13 6 2 mm 0 24 Terminal or less e When two wires are connected to one terminal 3 2 0 13 6 2 mm 0 24 Terminal Crimp or less ag terminal 6 3 mm 0 25 or more 3 2 0 13 6 2 mm 0 24 I a Terminal or less 6 3 mm 0 25 or more 3 2 Power Supply Wiring For the power supply wiring refer to the following manual Refer to the FX3U FX3UC Series User s Manual Analog Control Edition 3 3 Wiring of Analog Output For the terminal layout refer to Subsection 1 2 2 External power supply wiring Grounding Ground resistance 1002 or less Using voltage output Shield 3 ch FX3uU 4DA at gt 15v e 24V DC 1 Q F lt r P aia Using current output h R 3 ZX Eo it ey N chO O represents the channel number For FX3U Series PLC AC power type the 24V DC service power supply is also available 2 Leave the e terminal un
17. lied to the PC board thereby causing nonconformity When drilling screw holes or wiring cutting chips or wire chips should not enter ventilation slits Such an accident may cause fire failure or malfunction Be sure to remove the dust proof sheet from the PLC s ventilation port when the installation work is completed Failure to do so could cause fires equipment failures and malfunctions Fit the extension cables and communication cables securely to the designated connectors Contact failures may cause malfunctions 2 1 Arrangements The product connects on the right side of an PLC main unit or extension units blocks including special function units blocks For connection to FX3UC Series PLC or FX2NC Series PLC extension block FX2NC CNV IF or FX3UC 1PS 5V is required For further information of installation arrangements refer to the following manual Refer to the FX3U Series User s Manual Hardware Edition 2 2 Mounting The product is mounted by the following method e Direct mounting e DIN rail mounting 2 2 1 Direct Mounting The product can be mounted with M4 screws by using the direct mounting holes Refer to the External Dimensions section 1 2 for the product s mounting hole pitch information An interval space between each unit of 1 to 2 mm 0 04 to 0 08 is necessary For further information of direct installation also refer to the following manual Refer to the FX3U Series User s Manual Hardware Editio
18. load 1kQ to 1MQ External load 500 Q or less Offset 10 to 9V 0 to 17mA Item Gain 3 to 30mA 2 Digital input 15bits binary Resolution 0 63uA 20mA 32000 e 0 3 60mV for full scale of 20V when ambient temperature is 25 C 5 C e 0 3 60uA for full scale of 20mA when ambient temperature is 25 C 5 C 0 5 100mV for full scale e 0 5 100uA for full scale of 20V when ambient of 20mA when ambient temperature is 0 C to 55 C temperature is 0 C to 55 C Total accuracy A D conversion time 1ms The number of selected channels will not affect this value e Output mode 0 e Output mode 2 Output voltage V Output current mA 20 44a Sa 209 a SSS 32000 0 32000 32640 Output Digital value characteristics 4 Output mode 3 Output current mA 20 32 re a atic l 20 Kl I l I l p I l I l I l l 0 32000 32640 Digital value e The photo coupler insulates the analog output area from the p PLC meuaton e The DC DC converter insulates the analog output area from the method power supply unit e Channels are not insulated from each other alii 8 point Count either the input or output points of the PLC 1 Change the offset and gain values to change the output characteristics However the resolution doesn t change even when the offset and gain values change When analog value mV A specification is enabled in the output mode 1 or 4 the offset value and th
19. n 2 2 2 DIN Rail Mounting The product can be mounted on a DIN rail DIN46227 35mm width 1 Fit the upper edge of the DIN rail mounting groove right fig A onto the DIN rail 2 Press the product against the DIN rail 3 Connect the extension cable right fig B to the main unit input output extension unit block and special function unit block on the left For the details of the extension cable con nection refer to the following manual Refer to the FX3U Series User s Manual Hardware Edition 3 Wiring EN lt SDANG ER e Cut off all phases of power source externally before installation or wiring work in order to avoid electric shock or damage of product WIRING PRECAUTIONS CAUTION e Make sure to observe the precautions below in order to prevent any damage to a machine or any accident which might be caused by abnormal data written in the PLC due to the influence of noise 1 Do not lay close or bundle with the main circuit high voltage power line or load line Otherwise effects of noise or surge induction are likely to take place Keep a safe distance of more than 100 mm 3 94 from the above when wiring 2 Ground the shield of the twisted shielded cable at one point on the signal receiving side However do not ground at the same point as high voltage lines e Properly perform wiring to the terminal block following the precautions below in order to prevent electrical shock short wire brea
20. nding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the FX3U Series User s Manual Hardware Edition Another Another Another Q Q Q O O O Independent grounding Shared grounding Best condition Common grounding Good condition Not allowed e The grounding wire size should be AWG 14 2 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specification STARTUP AND MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify the unit Doing so may cause failure malfunction or fire For repair contact your local Mitsubishi Electric distributor Do not drop the product or do not exert strong impact doing so may cause damage DISPOSAL PRECAUTIONS NCAUTION e Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS NCAUTION e During transportation avoid any impact as the product is a precision instrument Check the operation of the product after transportation 4 1 Applicable PLC Model name FX3U Series PLC Applicability Ver 2 20 from the first product and later Ver 1 30 from the product manufactured in August 2004 with SER No 480000 and later FX3UC Series PLC The version
21. o the FX3U Series User s Manual Hardware Edition 3 Wiring WIRING PRECAUTIONS DANGER e Cut off all phases of power source externally before installation or wiring work in order to avoid electric shock or damage of product WIRING PRECAUTIONS CAUTION e Make sure to observe the precautions below in order to prevent any damage to a machine or any accident which might be caused by abnormal data written in the PLC due to the influence of noise 1 Do not lay close or bundle with the main circuit high voltage power line or load line Otherwise effects of noise or surge induction are likely to take place Keep a safe distance of more than 100 mm 3 94 from the above when wiring 2 Ground the shield of the twisted shielded cable at one point on the signal receiving side However do not ground at the same point as high voltage lines e Properly perform wiring to the terminal block following the precautions below in order to prevent electrical shock short wire break or damage to the product Termination of the wire should follow the dimensions described in this manual Tightening torque should be 0 5 to 0 8 Nem 3 1 Applicable Cable and Terminal Tightening Torque The size of the terminal screws is M3 The end disposal of the cable shows below Tighten the terminal to a torque of 0 5N m to 0 8N m e When one wire is connected to one terminal 3 2 0 13 Terminal Crimp 6 2 mm 02 OR oe Aen or les
22. onversion 8 DIN rail mounting hook 9 DIN rail mounting groove 35 mm 1 38 wide 1 2 2 Terminal Layout gt ve v vi JY Left side of the product Extension cable side 2 Installation INSTALLATION PRECAUTIONS CAUTION e Use the product in the environment within the general specifications described in PLC main unit manual Hardware Edition Never use the product in areas with dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibrations or impacts or expose it to high temperature condensation or wind and rain If the product is used in such a place described above electrical shock fire malfunction damage or deterioration may be caused Do not touch the conductive parts of the product directly thus avoiding failure or malfunction Install the product securely using the DIN rail or screws Install the product on a flat surface If the mounting surface is rough undue force will be applied to the PC board thereby causing nonconformity When drilling screw holes or wiring cutting chips or wire chips should not enter ventilation slits Such an accident may cause fire failure or malfunction Be sure to remove the dust proof sheet from the PLC s ventilation port when the installation work is completed Failure to do so could cause fires equipment failures and malfunctions Fit the extension cables and communication cables securely to the designated conne
23. s 3 2 0 13 6 2 mm 0 24 Terminal or less e When two wires are connected to one terminal 3 2 0 13 6 2 mm 0 24 Terminal Crimp or less screw terminal 6 3 mm 0 25 or more 3 2 0 13 6 2 mm 0 24 1 Terminal or less 6 3 mm 0 25 or more 3 2 Power Supply Wiring For the power supply wiring refer to the following manual Refer to the FX3U FX3UC Series User s Manual Analog Control Edition 3 3 Wiring of Analog Output For the terminal layout refer to Subsection 1 2 2 External power supply wiring Grounding Ground resistance 100Q or less Using voltage output FX3uU 4DA 15V Ze na 24V DC 1 Se 4 oOo ays 4 E A A aie ae 5 DE 1 O O m T aba 4 S chU Cl represents the channel number 1 For FX3U Series PLC AC power type the 24V DC service power supply is also available 2 Leave the e terminal unconnected 3 Use a 2 core twisted shield wire for analog output line and separate it from other power lines or inductive lines 4 If there is ripple or noise in the output voltage connect a capacitor of approximately 0 1 to 0 47 uF 25 V in the vicinity of the signal receiving side 5 Ground the shielded wire at one point on the signal receiving side 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 100Q or less e Independent grou
24. s The output characteristics in each output mode are as follows Output Digital input Output mode Analog output mode range range 0 Voltage output mode 10 to 10V 32000 to 32000 1 Voltage output analog value 49 14 410v 10000 to 10000 mV specification mode 2 Current output mode 0 to 20mA 0 to 32000 3 Current output mode 4 to 20mA 0 to 32000 0 to 20000 4 Current output analog value 0 to 20mA uA specification mode This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles
25. tallation and maintenance JY997D16501 MODEL CODE 09R516 FX3U Series User s Manual Hardware Edition Note FX3UC Series PLC specification details for I O wiring installation and maintenance can only be found in the Japanese Manual How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Certification of UL cUL standards The following product has UL and cUL certification UL cUL File Number E95239 Models MELSEC FX3U series manufactured FX3U 4DA Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive and LVD directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Requirement for Compliance with EMC directive The following products have shown compliance through direct testing of the identified standards below and design analysis through the creation of a technical construction file to the European Directive for Electromagnetic Compatibility 89 336 EEC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Models MELSEC FX3U series manufactured from February 1st 2006 FX3U 4DA Stand
26. tection is provided then users may experience temporary induced errors not exceeding 10 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed with general good EMC practice for the users complete control system users should expect normal errors as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used Ground the shield of the twisted shielded cable at one point on the signal receiving side e Please use FX3U 4DA while installed in a shielded enclosure For the details refer to the following manual Refer to the FX3U Series User s Manual Hardware Edition 1 Outline The FX3U 4DA special function block for analog output converts digital values supplied from PLC into analog values voltage current and outputs those analog values from its four output points 1 1 Incorporated Items Check if the following product and items are included in the package Product Manual Special unit block No label Dust proof sheet x 1 This manual 1 2 External Dimensions Part Names and Terminal Layout 1 2 1 External Dimensions and Part Names Without top cover 4 2 80 3 15 mounting hole pitch

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - M    Sunrise Medical Guardian IC-5207 User's Manual  Bedienungsanleitung  TSB 1110650175 (CVF).indd    PROFESSIONELL SOLE / WASSER - Alpha  巡警告  J-25 PASTA BLANCA AL ACEITE  

Copyright © All rights reserved.
Failed to retrieve file