Home
Security Commander for Windows
Contents
1. 0111222200000030 10 10 01 23 18 38 10 6 1000 SIA DRBC Dis rmingl Dis med 0111228100000030 1110 10 01 23 18 40 10 6 1000 SIA Troubles Distmed Ill 0111222200000030 1010 01 23 18 43 10 6 1000 SIA DRBC Dis rmingl 0111228100000030 1110 10 01 23 18 44 10 6 1000 SIA DRBE Troubles Distmed 0111222200000030 1110 10 01 231853 10 5 1000 SIA DRBE _ Arming Armed 011122 100000030 11010 01 23 18 54 10 6 1000 SIA Troubles Armed 0111222200000030 10 10 01 23 18 57 10 6 1000 SIA DRBC DisArming 0111228100000030 1010 01 23 18 59 10 6 1000 SIA _ Troubles Distmed 0111222200000030 k HecLnt 38 2 As you can see window consists of header and information field Information field content is formed from the events received by central unit and cannot be edited Header is filled by user in free form In the current program version there is a possibility to save archive
2. Maintenance when object is in this mode all messages from it are Open in new window not followed by sound signal and alarm window Usually used not to distract an operator when object is under maintenance Set Msg send SMS message to the object To use this function a GSM modem must be connected and object device must be able to receive SMS messages RT4 5gc RT4 5gs Service is executed starts a count down timer to the next servicing Show displays object on a map in the Tracking software To do so it s necessary to create in the Tracking software a static object with the same number as in WinSC Filter adjustment window Event window Displays messages from all objects registered in DB in chronological order Every message is shown in one row and marked out in color depending on it s type Messages that are not processed are shown in upper part of the table depending on message priority the higher priority the higher message is Unprocessed messages are marked out by Bold font and underline Processed messages and messages with equal priority are shown in order they were received the later the lower To process a message in alarm window choose it in the list select it and press Enter Event window also has a number of 77 History adjustable parameters Parameter adjustment is made just like in object window through context menu right mouse button Using this menu you c
3. N D DisArming Arming N FE N 5 T 220V failure 220 T T Battery low H Battery H l4 4 s 5 P Panic T Trbl w PwH A Arm OD DArm H Hestore E Event RP1000 repeater RP1000 repeater transmits to CU information about state of the two tampers AC backup battery and test messages every 12 hours Recommended zone assignment is shown on the picture below Objects Details one Events TLF Events work Schedule Hardware Hotes Zone e Zone J 5 T Battery low Battery OF H di T lost N 2 T Device tamper R Device tamper restore H I N 3 T Room tamper R Room tamper restore H dd Xl 4 s X W PWR 4 Arm D DAm R Restore E Event RP4000s repeater RP4000s repeater transmits to CU the same information as RP1000 but with the different zone numbers Recommended zone assignment is shown on the picture below Objects Details one Events TLF Events Work Schedule Hardware Notes Nn rfe jM t MIL 1 T Battery low Battery H T lost AC OK N da H 57 T Device tamper Device tamper restore H H 58 Room tamper Room tamper restore H I l4 4 X B Bur T Trbl W PWH A Arm D DArm 4H Hestore E Event RP4000d repeater RP4
4. Account field has the following structure AAAAGG Where G partition number A panel account There are no any additional symbols between partition number and panel account If panel account is shorter than 4 symbols than left zeroes may be discarded Number of symbols in partition number must always be two For example if panel account is 123 and partition number is 2 than you must enter the following in the Account field 12302 Event field always consists of 7 symbols and has the following structure MEEEZZZ where modifier E event code see code table in the panel manual 2 zone or user number if the event doesn t describe any zone or user actions than you have to enter zeroes there M modifier in the Event field may possess 2 values 1 if the event is alarm or disarming M 3 if event is alarm restore arming or information service event Not described event will be displayed in the following way Event 1137001 Account 2345 01 TLF Events tab In this tab are described signals that are received from control panels using wire line channel phone line or GSM channel Program supports different kinds of alarm receivers Central units and this list expands all the time Every central unit has it s own message format that he transmits into the program Also format may depend on the central unit individual settings Considering the above it s not suitable to describe event programming for every central uni
5. event type there can be more than one event with A or D values for one object 8 R Restore alarm restore for types 1 5 9 E Event neutral event 10 S Tst Control panel test message This is not an information event but if it won t be received in a time period that determined in Object test time field a following event will be displayed No signal from object Message Message designed for describing event that corresponds to the current event code If this field is not filled than event is ignored no matter what type it is If a message is received that is not in the database than it will be displayed as an E Event type The way message will be displayed in the following way Partitionz P EventCode E where P partition E event code Partition number may contain up to 3 HEX numbers event code up to 8 symbols If partition number is not transmitted message will be displayed in the following way Partition EventCode E rEv Restore code In this field you have to enter a code receiving which an alarm message 1 5 event types will be deleted from Alarm List window If the code is not entered you will have to manually delete event from Alarm List window R can take two values Y alarm event is added to Alarm List window not added This function will work only if Reminder timeout parameter in the window header has nonzero value Same as describing events t
6. Event type Possible event types are listed below P Panic alarm event Received when a panic button is pushed on the object F Fire alarm event Received when a fire alarm goes on B Bur alarm event Received when burglary alarm goes on T Trouble alarm event Describes different object malfunctions tamper alarm low battery etc 5 A Arm object arming 6 D DArm object disarming As opposed to zone programming when programming an event type there can be more than one event with A or D values for one object R Restore alarm restore for types 1 4 E Event neutral event S Tst Control panel test message This is not an information event but if it won t be received in a time period that determined in Object test time field a following event will be displayed No signal from object Message designed for describing event that corresponds to the current event code If this field is not filled than event is ignored no matter what type it is If a message is received that is not in the database than it will be displayed as an E Event type The way message will be displayed depends on the type of interface module S Qo 4 rEv Restore code In this field you have to enter a code receiving which an alarm message 1 4 event types will be deleted from Alarm List window If the code is not entered you will have to manually del
7. TLF E vents Work Schedule Hardware Notes Control Pane 0 Transmitte RT4 5se Manuk Korteks zones Interface Mame 8 0 1 SME W 2 Cp E 3 Optex mj 4 B SME I Optex X In the page header you enter type and manufacturer of the control panel and type of the trannsmitter and interface module if installed Lower there is a table where you describe hardware that is connected to control panel and transmitter inputs Table contains the following fields Nr number of panel zone or transmitter input Tx zone belonging to control panel Cp or transmitter Tx Name Zone description Sensors sensor description All fields are filled freely This information can be requested by the operator when pressing the Hardware button in alarm window or on the information panel in program general window Notes tab In this tab you can enter any additional information about the object in plain text This information can be requested by the operator when pressing the Notes button in alarm window or on the information panel in program general window Size of entered text is not limited User database editor Due
8. amp 1 1011 Time Mr Mame EvTvpe Status Message Staus Message ooo Report 10 SIA DRBC 3a 10 10 2001 Time Nr D Name Status sage 15 49 14 10 E 1001 SIA DRBC Troubles Armed 15 49 15110 5100 SIA DRBC Troubles Armed 220 16 49 17 7 10 6 1004 SIA DRBC Restore Armed 22M OK 15 49 19110 E 100 SIA DRBC Troubles Armed 220M 15 49 2010 E 1001 SIA DRBC Restore Armed 220v 17 08 41 1 51000 SIA DRBC Restore Armed 17 09 41 1U 5100 SIA DRBC Troubles Armed 220M 17 08 58 1U SIA DRBC Restore Armed 17 10 00 1U O00 SIA DRBC Troubles Armed 17 10 02 10 67100 SIA DRBC Arming Armed 17 10 04 10 51000 SIA DREG Troubles Armed 1 10 05110 51000 SIA DRBC DisArming DisArmed 17 10 07 10 E 1001 SIA DRBC Troubles DisArmed In this window there are follow
9. power supply status black power supply ok M blinking red power supply failed communication status black communication ok blinking red communication failed Control panel _2 SALARME Administrator Sh End session 14 53 06 Control panel Control panel has following indication and control elements from left to right unprocessed message counter unprocessed message indicator button to open program for log file review see working with log file button to open not restored alarms list see Alarm List information window current operator name button to end current operator work session help button current time Program main menu Program main menu Hot key Alt is designed to make basic settings and control general program functions Main menu consists of the following submenus File Utilities Archive Service About File submenu Consists of two items e End session Has the same function as button on the control panel initializes end of current operator work session e Exit Exit program Utilities submenu Consists of the items to work with object users operators databases e Users has following functions for specified users work with DB gt User DB Editor opens user DB editor see DB editors gt Opera
10. specified in the Closing field object is still disarmer an alarm message is formed Object not Armed f object was armed properly but was disarmed at the time that is out of the specified range another alarm message is formed Disarm in illegal time If you need to set a time interval that starts on one day but ends on another than you have to break it in two In the first day you set an interval that ends at 23 59 and at the other interval that starts at 00 00 Any other intervals that have time difference less than two minutes are also considered as one interval Example is shown in the picture below Objects Details one Events TLF Events Work Schedule Hardware Mates _ Opening Closing Opening Closing Opening Closing ___ b tr 19 00 23 59 07 00 22 00 2 00 00 08 00 07 00 22 00 In the picture object disarmed from 19 00 Monday till 8 00 Tuesday If the day is added into the schedule but no time is set for it it means that object must be armed all day If the day is not added into the schedule than the schedule is not monitored this day If an object has the same schedule for all days of the week than you can simply enter the schedule for the Monday open a context menu using right click and select Copy Schedule will be copied for all week Hardware This tab is designed to describe the hardware that is installed on the object Objects Details One E vents
11. Bur A Arm D D m R Restore E Event 5 Tat In the Account field you have to specify interface module number from 00 to 03 see user manual for PARADOX_2 in the Event field group and event code Code table can be found in PARADOX_2 manual Not described event will be displayed in the following way Group Of Event Event 5001 Card number 02 IF_paradox interface module SPECTRA IF_Magellan control panels Example of event programming for this situation is shown on the picture below Objects Details Zone Events TLF Work Schedule Hardware Mates p pest Tevet cote Tn TT c 1C0101 T 220 H 100201 13 o 01 1CO301 H 01 120401 H 3101 100101 220 N 3101 100201 N da 01 100301 01 100401 H 3101 1E0401 T N H3 01 1E0501 H l4 Hp gt F Fire B Bur W PWR A Arm D DA m H Hestore E Event 5 Tst In the Account field you have to specify interface module number from 00 to 03 see user manual for PARADOX_2 in the Event field group and event code
12. Diesel 2 0 14 AC RESTORE v 2007 cho Chl wm ChS mm ChG Ch ME Pwr La 2 Disk 158 4 66 37 Pic 1 General Monitoring window 1 Program general window 2 Control panel 3 Event window 4 Information toolbar 5 Object window 6 Status panel In this window you can see all operative information about objects and system status information You can also control all program functions and open general services Object window This window is made in a shape of a table that contains all information about objects registered in DB opened for monitoring For better visualization objects in the History table are shown in different colors depending on the type of the last message Black Picture Ctrl F color means that there were information messages since object registration or its last Makes editing Objects removed from monitoring shown in gray color Details Window has number of parameters that can be adjusted by user Parameter AM Hardware Ctrl 4 adjustment is made through context menu right mouse button Using this menu you can also open additional information about selected object open object editor and WP Problem search objects in the table Menu appearance is shown on the picture You can open Archive additional object information by using following commands e History operative display of
13. H 34 T loss in 4000 Restore in CU4000s H B H 35 T No backup battery in CLE AUOD Restore backup battery in CL 4060s H H 36 T Low backup battery in CU4000s Restore backup battery in CL 4060s H H T Backup battery overcharged Restore backup battery in CU4000s 4 FP Panic T Trouble A Arm D Disarm R Restore E Event CU4000 event description WSC Editor Editor me mi E Name MLR208 Description Reminder timeout 00 00 Settings Objects fone Events Notes NR ___ M Message ey 01 T Printer Error 02 N _ 02 Printer Restored w A03 12V Battery Low 04 N HB _ 04 12 Battery Restored N A 05 T COMH Absent 06 N __ R 06 R COMH Restored N _ 07 T UPS AC Fail R 08 N R 08 R UPS AC Restored N JM A 11 T 9V Low R 12 N R 12 9 Restr 7 P B Bur T D DArm H Hestore E Event 5 Tat MLR2 DG event description Working with archive All events received from objects operator actions and operator comments to processed events are saved in the archive Archivated data is saved for all working period and can be sorted displayed on the screen saved to file and printed at any moment and for any time period You can open archive filter
14. Message sending field 2 Communication field To send a message just type it in the sending field and press Enter In the communication field are shown central unit s service commands and events Communication port configuration for this device is made by editing the ComRp ini file that is located in the program main folder Port settings must look the following way Baud 57600 DataBit 8 Parity 0 StopBit 0 FlowCtrl 0
15. Timeout for events 0100 zones transmitter inputs and events ces andi c If a checkbox To ignore duplicate messages is active foo than program will consider any duplicate messages aaa received in a determined period of Deaf time field as Pe ONE Et one message Program reaction can be the following None duplicated message isn t shown in event window Alarms only alarms are shown All programmed events are shown In case if the message is duplicated it s marked with d symbol Cancel WSC Options E 31 xl Groups Classes air alarm Time Sound Timeouts Picture Signals Comments r Picture viewer Pictu re Dete rmines prog ram wh ich WI C Program Files Paint Shop Pro be used to open graphical attachments WSC Options Groups Classes On air alarm Signals Allows setting a unique sound Time Sound Timeouts Picture Signals Comments signal for every type of event To set a sound just select an appropriate WAV file This file Panic sounds sound3 WAV ES can be located either in the Sounds folder or in Fire sounds sound4 wav m any other place of the hard drive This option is Burglary sounds sound wav only available is a sound is set as sound Troubles WAV EI device Not Armed sounds sound8 way n No signal Jsounds sound 11 WAV Closing Jsounds sound13W
16. a time period is set TO mmiss and TO mm s 30 00 a number of messages that can be sent during this period Count If a number of messages exceeds adjusted number the alarm message is generated Message looks like this Transmitter XIYIZZZZ on air where X channel number Y slot number ZZZZ transmitter number Receiver settings Receiver settings window can be opened through main menu in the program general window Service Receivers Settings Due to the fact that many of the settings affect program functionality it is recommended that they would be configured only by qualified personnel Receiver settings window appearance is shown on the picture below x Channel numbe Sours Ma Receiwer typ EM LL Cancel Port setting When configuring receiving channel you can set the following parameters Channel number Number of a channel Used to identify objects wis Receiver Type type of the receiver assigned for es S A this channel Receiver type can be chosen from the Cu 4000 pulldown list by clicking E symbol Content of the list i rmin he presen f th ropri Silent Knight 9000 st is dete ed by the presence of the appropriate ADOD drivers in the program main folder Source determines the information source for the program It can either be a COM port with attached receiver or log file that is created by the similar
17. control panel via SMS or GPRS channel For transmitters own messages Partition Nr is always FF In case if for event receiving is used GPRS channel than event code will contain two symbols see picture below Objects Details one Events TLF Events work Schedule Hardware Mates E d B Alarm zone is ft D Disarm N 35 T Low batery N d 39 T AC lost N d ff 9 R Restore zone 2 H 5 ft 83 E Changed N dd __ 94 N mo 95 Batery is N dd 96 Test time N 1 ff a7 E Programming 3 l4 P Pamc F Fue B Bur W PWHR A Arm D DArm E Event 5 Tst Event code when using GPRS channel In case if for event receiving is used CU GSM central unit you have to insert two zeroes between code symbols see picture below Objects Details one Events TLF Events work Schedule Hardware Mates ducc ramum lee E dd 300 B Alarm zone 2 N d Jn 3004 D Disarm N d Jn 3005 T Low batery N ft 3009 T AC lost N d 900 Restore zone 7 d 8003 E Changed N d __ 9004 N mo 9005 Batery is N dd jm 9006 Test time N 1 ff 3007 E Programming 1 l4 4 5 P Panic W PWHR A Arm D DArm R Restore E Event 5 Tst Event code when using CU GSM
18. off certain information fields 1 Port computer port number that received the message Slot number of the receiver slot that received the message Dat data block ST receiver slot type DateTime date and time of message receiving ID transmitter repeater address Tst test message flag Serv repeater service message flag HI oh the last repeater that the message went through 0 HN number of message repeats 1 LV received signal level 0 7 If the message was repeated than it shows the level of receiving by the first repeater 12 Source original log file row where the message was taken from Note f the message is receive directly in HI field may be displayed number of repeater to which transmitter is assigned Font allows choosing optimal font type and size Filter On allows choosing and activating message filter for certain fields see picture Filters for different fields may be activated at the same time In this case only information that answers all criteria is shown In the criteria field you can specify either parameter value or value interval When a new criterion is assigned the old one is canceled When filter is activated window lower panel turns yellow and all criteria are shown there see picture below Filter Off Cancels all filtering To cancel filtering in the current field you have to open criteria window leave the field empty and press when opening
19. previous command e Editor opens object editor Hot Key Ctrl E e Search allows searching in the table using additional menu fields In the Nr field search is made using object numbers in other fields using any record fragment Search is started from the first record Object window context menu to file allows saving table content as text file with field separation with tab and opportunity to import it into MS Excel Filter On opens information filter adjustment window As seen on the picture you can adjust window for display of the objects depending on their status armed disarmed 24hour arming unknown status type of the last message and their belonging to defined groups or classes Also you can display this information in new window leaving general window not filtered Stus 7 information You can open up to Open i i W Close W Group 1 with i 24hour W Group 2 Cancel individual filtering in each e Unknow k Group 3 filtering is made in general window Group 4 field headers are marked out by red color If in additional in status panel are shown number of objects in the window and types of V Nore filtration Additional window field Fire Store settings are identical to the general d nudis eee window field settings Restate H Filter off Cancels information filtering in general window ivi E
20. program on any computer on the local network Filename name and location of the log file Fllename that is used to gather information from Change of the file name when it s required is made z 9 2 003113109 automatically of the signal transfer Sets correspondence between physical number of the slot or phone line in the receiver and it s logical number in the program It is used when information from the object can be received from more than one slot line and you can only set one in the program Port setting used to configure the COM port to correctly work with the current receiver Communication parameter values should be specified in the receiver manual After pressing OK button all configured parameters will be saved chosen receivers are added to the system object database if they weren t added previously and all used ports are reinitialized DB editors Object database editor Object database editor is designed for creating object cards filling them with appropriate information about object and signals received from it and for systemizing and saving this information You can open object editor from nformation panel using Edit button Context menu in the object window using Editor command Context menu in the event window using Editor command Keypad using Ctril E key combination When opening an editor it opens a card for the object that
21. selection into the text file with opportunity to import it into MS Excel To do so you have to open context menu using right click and select Save to file option Also this context menu has a Font that allows choosing optimal font type and size and Visible fields option that allows to remove not needed fields Archive selection window can contain the following fields Date message receiving date Time message receiving time Nr object number in the database Rnum receiving channel number see Receiver settings 10 message source receiver number slot line number device address Name object name Event type event type Status object status at the moment of receiving the message Armed Disarmed Message event description Data data block received from the receiver physical address oh the last repeater that the message went through for CU4000 only number of message repeats for CU4000 only TG data transmitting type for CU4000 only name of the operator that processed the message Slot type slot type for CU4000 only Slot slot line number that received the message Pressing the symbol will open report printing window Report printing window appearance and it s context menu is shown in the picture below This window will have the fields defined in the archive selection window gt _ x BES
22. was selected in the object or event window Object card consists of the heading and several tabs of information grouped according to it s type Header and the first tab Object editor appearance is shown on the picture below WSC Editor EU Editor Object Mr SSS 4 X N Transm test time 25 00 si Korteks Object test time 25 00 Description Liksnas 7 Reminder timeout 01 00 Radic Fhan 01 00 Ts Addess 253 Slat ps xj Mainten period MM DD Channel Device type Tx Channel Mail Boies Mame Objects Details Fone Events TLF E vents Work Schedule Hardware Mates amp 253 51 Korteks 21 07 2010 First tab is a list of objects cards Selecting an object will show it s header Header contains the following fields and buttons Object object sequence number in the DB When you are creating a new object you will automatically be advised to use the first unused number but you can choose the next one or use any other If the background is green object is active if red removed from monitoring see Work Schedule tab Name Object name Filled freely max 80 symbols Description Object description Filled freely max 80 symbols lt button move to the first object lt button move to previous object gt button move to next object gt button move t
23. window from the Archive option in main menu using context menu in the object or event windows Archive command In the first case you will see three submenus that determine general sorting parameter Sort by Number allows sorting objects or object groups by their numbers in the DB Sort by Tx Address allows sorting objects or object groups by the number of the transmitter installed there Sort by Account allows sorting objects or object groups by the account of the control panel if information is delivered by wire line channels If you open archive filter using context menu than Sort by Number window will open Number of object that was selected for context menu opening will be automatically added to the sorting field Appearance of all three windows is shown on the pictures below WSC Archive filter x Tim From 00 00 Al System events To 23 59 Insertion Obj whale day Insertion User Removing User Editing User Processing Not armed Ma signal Ts signal 0 hi Sort by Number window WSC Archive filter 2 xl Dat Fram 26 11 2007 To 2611 20 Timi From 00 00 2358 System events Insertion Obj Removing Obj Editing Obj Insertion User Removing User Editing User Processing cnc Sort by Tx Address window To receive information about repeaters you have to add r prefix before the address For example r
24. 000d repeater transmits to CU the same information as RP1000 but with the different zone numbers Recommended zone assignment is shown on the picture below Objects Details one Events TLF Events Work Schedule Hardware Hotes Lu Exe 11 1 Battery low Battery H 2 lost R AC OF H Fi T Device tamper H Device tamper restore H 8 tamper tamper restore H d E 4 OX W PWR A Arm D DArm E Event Events tab In this tab are described signals that are received from control panels Event codes are read from the control panels using interface modules that are connected to the inputs 1 and 2 of the receiver In that case these inputs work as serial port Event code transition is only possible using RT4 5se transmitter RS4000 system To describe an event the following fields are used NR object number This is an information field and can t be edited Account Contains information that allows to identify control panel For different types of interface modules can have different structure see below Event must contain an event code that is generated by control panel For different types of interface modules can have different structure see below Code must be entered fully including left 0 5 M E mail sending Filled exactly the same as in the Zone tab T
25. 01 01 090001 0 90001 Dl 0 08 04 12 57 47 90001 20007 gt 0 08 04 1 3 00 30 EGO 20008 gt 0 08 04 13 07 35 20008 ADTFF gt 071 08 04 13 07 45 90001 gt 01 0 08 04 13 07 46 ADTFF 90001 OF d 04 08 2009 13 07 39 Connected to 213 21 196 42 0 ADIFF 212 93 97 166 4116 COMO Slot 84 2003 08 04 13 13 13 FFOSOFFOT OO000000000000003 01 0 1 Message sending field 2 Connections window 3 Communication window Command entered in the message sending field must have the following structure XXX YYY where XXX repeater ID YYY command text To send command press Enter In the connections window is shown the following information Repeater ID Repeater IP address number of messages the current session last repeater message In the communication field are shown repeater s service commands and events In the window header is also shown communication port that is used to establish connection see picture Default port is 925 but you can change it by editing file that is located in the program main folder ComRP window In case if RP4000dm is connected to computer using Command COM port USB port and used as central unit E icon will appear in SysTray When right clicked a ComRP window will open It consists of two parts 1
26. 103 b E Registration mode exit H 1012 0103 81 T fail N 11012 0103 82 T low N 1012 0103 9 Restore zone E 1012 0103 D Opening by user H 1012 0103 Closing by user E H 7 x H amp FP Panic F Fire B Bur T Trbl A 0 R Restore E Event 5 Tat If an event with the code 41 is received then operator will see the following message Alarm in zone 1 If an event with the code 43 is received then operator will see the following message FIRE alarm There are different issues in programming according to the interface module you are using but the principles of using are the same PARADOX 2 interface module ESPRIT 7X8 control panel Example of event programming for this situation is shown on the picture below Objects Details fone Events TLF Events Work Schedule Hardware Mates JINR Account Eventcode T Message ev 1111 foo 5000 12V N 111 joo 5001 N 11111 joo 5002 N 1111 joo 5003 220 V N qnn 00 5006 H _ n 5300 12V N qnn 00 5301 H 00 5302 H joo 5303 T 220 N 111111 00 5800 rg 4 X F Fire B
27. 12 WSC Archive filter 2 xl Dat From 26 11 2007 To 26 11 207 Tim From 00 00 To 2358 System events Insertion Oby Removing Obj whale day E diting Insertion User Removing Editing User Processing Chane Mo signal Restoration Closing Gees Sort by Account window Note that an account number is in HEX format As you can see these windows are differing only by object identification parameters that are used to filter the archive All other selection criteria are the same and have the following purpose Date allows defining the day period for the sorting Time allows defining the time period for the sorting If in the Date field are selected a period of more than one day than sorting will be made from the From time of the first day to the time of the last Whole day if active sorting is made for the whole day Event Type 1 allows defining types of the operator actions and system events that will be used for sorting Event Type 2 allows defining types of the object messages that will be used for sorting Operator allows choosing only events processed by current operator After all of the criteria is set press Ok button Time of the archive selection forming depends on the selected time period amount of the requested information and computer performance and may take up to a few minutes To stop archive selection form
28. AV E Cancel WSC Options E 31 xl Groups Classes n air alarm Time Sound Timeouts Picture Signals Comments Comments This is a list of standard comments used operator when processing events in the alarm window To edit a comment just double click it in the list CO OO 7 CD Co Note by default Time Sound Timeouts Picture Signals Comments Groups Allows creating and renaming Classes On air alarm groups where you can later assign objects see DB editors Number of groups is not limited When deleting a group and creating a New Group new one on it s place all the objects that Group 5 MewBou where assigned to the deleted group will automatically be assigned to the new one Cancel OK Cancel WSC Options Time Sound Timeouts Picture Signals Comments Groups Classes On air alarm Classes Allows creating and renaming object categories see DB editors Number of categories is not limited When deleting a category and creating a new one on it s place all the objects that where assigned to the deleted category will automatically be assigned to the new one air alarm Allows tracking 3 xl transmitters that transmit information too often L due to the connected devices malfunctioning To do so
29. As said above event codes can have different structures Usually communication formats and corresponding events are described in the central unit manual To find out the structure of specific event from specific object it is recommended to use the following method If you know the control panel account of the object just create new object card and enter this account into the Account field in the header see Header and the first tab section After that send a message from the object You will receive an Event type message that is assigned to the object you just created The message will have the following structure Partition P EventCode E Now just fill the card by entering received data into appropriate fields and when you will receive this message next time you will see an event description of the appropriate type If you don t know panel account then you don t need to create an object card but just send a message from the object In that case you will also receive Event type message but it will be assigned to central unit and will look the following way Receiver 1 Line 0 Acc 115 Part 1 EvCode C C4 As you can see this line contains full information to fill an object card In the TLF Events tab Replace command works exactly the same as in the Events tab but changes values in the Partition Nr field RT4 5gc GSM transmitter RT4 5gc GSM transmitter transmits information about it s inputs outputs and full information from connected
30. Attention In case if you are using RT4 5gc in GPRS transmitting mode it is strongly recommended to enter both types of events with and without zeroes in the middle to avoid receiving not described events if the GPRS connection will be broken for some reason Work Schedule tab In this tab you can schedule disarming arming for each object and program will automatically trace it s execution Schedule example is shown in the picture Objects one TLF Events Work Schedule Notes 1 08 00 20 00 07 00 22 00 Y xBr 08 00 20 00 07 00 22 00 xtp 08 00 20 00 07 00 22 00 4 amp ur 08 00 20 00 07 00 22 00 08 00 20 00 07 00 22 00 Monitoring Spare schedule In the left column you specify days of the week Then there are three Opening Closing column groups where you can set time of object arming or disarming In first two column groups are the main schedule in the third spare You can switch to spare schedule by activating Spare schedule checkbox To stop object monitoring without deleting it s object card just clear Monitoring checkbox In that case all messages received from this object are ignored and object number are highlighted red in the DB editor list see Header and the first tab section Schedule works the following way Time interval set in the Opening Closing fields determines the time when object may be disarmed If at the time
31. Code table can be found in PARADOX_2 manual Not described event will be displayed in the following way Group Of Event Event Partition 0D0401 Card number 01 IF 1 2 interface module Using this interface module you can read information from any control panel that has tlf communicator and supports 4x2 impulse transmission format see IF 1 2 user manual Also all control panels that are part of RS4000 system use this format Example of event programming for this situation is shown on the picture below Objects Details Fone Events TLF Events Wark Schedule Hardware Notes E 4 12 0001 12 0001 52 H 12 0001 43 0 H 12 0001 61 0 N 12 0001 b 0 H 12 0001 81 2208 T 12 0001 82 2 Y 12 0001 97 H E 0 12 0001 B D HE C H 12 0001 C 0 H 77 c gt P Panic F Fire W PWH 4 Arm D DAm H Hestore E Event 5 Tst In the Account field you have to specify control panel account in the Event field event code Panel account and event codes are programmed in contro
32. Control panel It not only allows seeing information in more comfortable way but can also filter data to sort out only necessary information LogView window appearance is shown in the picture below To print the report just press the 27 11 2003 14 23 51 Test S Log iew Alarmi wsc Maplogi 200311 3 log ae AI T EA 78 272127 4 7 D x 27 11 2003 14 23 51 1 02440000 0000001 mm 1 27 11 2003 14 23 50 1 02440000 00000012 1588 7 0 1 2 11 2003 14 23 50 1 02440000 0000001 1588 3 5E 1 2 11 2003 14 23 48 2 02440000 0000001 1588 4 5 0 1 27 11 2003 14 23 49 Test 0 23 550 1 n 5 27 11 2003 14 23 48 Test 1 00000000 00000032 1188 2 27 11 2003 14 23 47 Test 0 2 3 550 1 n 5 h 27 11 2003 14 23 47 1 02440000 0000001 1588 3 3 0 1 27 11 2003 14 23 46 Test 1 00000000 00000032 1188 210 27 11 2003 14 23 44 Test 1 100000000 00000032 320 3 0 1 27 11 2003 14 23 43 Test 1 00000000 0000001 2 1545 1 3 27 11 2003 14 23 43 Test 1 100000000 DODDDODIC Visible Fields 11 27 11 2003 14 23 43 Tee EaR ms h 27 11 2003 14 23 43 Test 1 00000000 00000032 FilterOn Id cu Filter Orr ra Slot Chrl 5 27 11 2003 14 23 41 Test 1 100000000 00000032 me y 27 11 2003 14 23 41 Test 0 00000000 0000001 1545 2 HN DateTime E eg Part Ctrl P Window has the following settings that can be accessed through the context menu Visible fields allows turning on and
33. LogView it automatically opens log file for the current decade If you need to see dd d E E information for an earlier period just press i button and select needed file from the list button is designed for switching the viewing mode If button is pressed real time view mode is on In this mode any newly received message is displayed If button is not pressed then hystory view mode is on You can also switch between modes using and End buttons If filter is activated than real time mode is identified by green field with Only new sign in the lower right corner of the window there see picture below So Log iew S Alarm wsc amp Maplog200311 27 11 2003 16 03 33 27 11 2003 18 03 28 1 100000000 0000001 1591 2711 200315 03 08 Test 1 00000000 0000001 1591 1 4 0 1 27 11 2003 18 03 08 Test 1 00000000 0000003 1532 1 5 1 Fite HN 1 14150020 OO Fields can be arranged in any order To move the field just drag n drop it to the preferred position Program additional windows RP4000dm monitoring window In the monitoring window is displayed all the information about RP4000dm repeaters connected to the program After you ve added the repeater you will see a E icon in the SysTray When pressed it will open monitoring window that consists of 3 parts Connections Port 925 B x he 30001 52 212 206 171 afar COMO SlotO 4 2003 0804 13 13 00 01080010000000000000000
34. Security Commander Windows 4 3 XX User manual Table of contents Security Commander for 1 nett eg sh tos peepee bea ke itd ties ada 2 dile deseo oe Sa esse deme weston EEE EE 3 Obiect asit NT 5 07 a eal mn 9 mE 9 10 Alarm list mformaton icici iio ti tp Vt d cs 10 sins pn il ec pte ln caer dn 10 DB editors _____ _ _ _ _____ _ _________ 14 de m Uc RE CERTE 14 Bini cud rt a 15 Bosco 17 Ee 19 Rem 17 tata tice cule ites unig 20 Posuit Ac hahaa ncn a A 25 ur E elt tk eae ae 26 NDERIT 26 Monitoring nee ene nee etme enemy NT Seer eer 33 ComRP iin tss cat ccc adil ccasacici 34 General information Security Commander for Windows software designed to organize workplace of the security signalization system operator Software works under Windows 9x 2000 XP OS and provides following functions processing of the messages that simultaneously come from several central stations up to 15 received information visualization message tracking signal
35. add Y and set Reminder timeout value as zero Alarm window Alarm window is information window but it has few special features that should be reviewed additionally Window appearance is shown on the picture Object Nr21 14 2 0 54 No signal 30 07 10 01 No signal more then 3 days _ Persons g ich hs Address Phone City Group None Fax State lass None Mobile ip All Ok E mail SE History M Hardware EH Picture l Sound off 7 Show CW ait w Ok Alarm window initializes automatically when alarm message is received This window is always active and placed in front of the others program windows Alarm window initialization is always followed by sound signal Alarm window consists of the following components aS Header contains information about an object that sent an alarm message 1 First row object number in DB and information source ID transmitter address panel account etc 2 Second row event type object status date and time 3 Third row object name see DB Editors 4 Fourth row object description see DB Editors Event description contains short description of event on the object see DB Editors In case if window initializes from not restored alarms reminder R symbol is added to the event description If received message is the same as received earlier d symbol Information panel Contains but
36. allowed for every access category there are a access level editors You can open them using main menu Utilities Users Operator Access Utilities Users Manager Access Utilities Users Supervisor Access Access level editor window is shown on the picture and are the same for all three access categories The following functions can be edited Exit ability to close the program Archive view ability to view the archive Archive print ability to print the archive Object edit ability to edit object database Rec settings ability to configure ports for receiver connection Archive view Options ability to configure parameters in Options Archive print Object edit Cursor setting ability to configure cursor jump mode in object window Operator access ability to configure operator access Options level Cursor setting ve E Manager access ability to configure manager access Operator access n dd Manager access Supervisor access ability to configure supervisor access level access Windows config ability to configure program windows Window config Max on alarm allows maximizing program window on alarm when alarm is received if it was minimized Save to file ability to use Save to file command Utilities ability to use program functions in the Utilities menu For every function there are tree access level
37. an also open TI Picture additional information about selected object Ckri T Menu appearance is shown on the picture You can open additional object amp Details Ctr D information by using following commands X Hardware DUUM e History operative display of the last ten messages from selected object Hot key Ctri H Picture display of the graphical information about selected object Archive Hot key Ctrl P puru Notes display of the operator s notes for selected object Hot key Ctrl T Visible Fields Details display of the advanced information about object and contact persons Hot key Ctrl D ee a Hardware display of the information about hardware installed on the Mot sensual object Hot key Ctrl A Problem allows operator to leave a note about a problem occurred on the object All notes are added to list where they can be processed Show and printed Hot key Ctrl Alt B Archive opens filter that can form archive selection for selected Event window context object see p Working with archive Hot key Ctrl B menu Editor Maintenance Note Only Latin register can be used for Hot keys The following menu options are used to adjust window interface Font allows setting optimum font size and type and changing encoding Visible fields determines fields that
38. ation toolbar Information toolbar has a number of buttons to open additional information about selected object Object can be selected both in object window and in event window Button functions are completely identical to the similar options in context menu Also this toolbar has search editor and cursor control buttons Status panel Status panel has information about current date disk space less than 100 Mb are shown in red color and receiver current status In each time moment are shown status of only one of connected receivers whose number is shown on the panel N where receiver number 04 04 03 Chi wCh2 ch ch Ch Wi Acc 1 Disk 2268 Status panel To select receiver you want to learn about you have to point mouse cursor on receiver number left mouse button click select necessary receiver from the list Every receiver status consists of slot line status power status and communication status Information is shown in a following way Slot line status is displayed by color black slot not installed not used for lines green slot line is functional blinking green slot programmed incorrectly or stopped not used for lines blinking red slot receiver or line failed backup battery status jo backup battery mm battery supply voltage low battery supply voltage ok A m battery supply voltage too high
39. card saves all described events in current object card to the text file 2 Load from card loads zone descriptions from selected text file Any zone description that was entered before is deleted 3 Append from card loads zone descriptions from selected text file Any zone description that was entered before will not be deleted For every receiver type zones have to be programmed differently RT4 5p transmitter RS1000 system RT4 5p transmitter has fixed amount of zones 5 User can freely assign first four of them but the fifth zone controls state of the power supply battery Zone 5 state 0 normal battery voltage 1 low battery voltage States of the other zones are sent depending on transmitter work mode Transmitter mode In this mode zone open state is sent as 0 and closed as 1 Control panel mode In this mode closed state of the status zone is always Arm status and sent as 1 Open state of the status zone is always Disarm status and sent as 0 For other zones their alarm state opened or closed is determined by transmitter programming and sent as 1 Zone restores are sent as 0 RT4 5se transmitter RS4000 system If no interface modules are connected than RT4 5se transmitter has 7 zones User can freely assign first six of them but the seventh zone controls state of the power supply battery Zone 7 state 0 normal battery voltage 1 low battery voltage Other zone state transmitting are de
40. d messages queue Those messages are placed in the upper part of the table according to priority the hither the priority the higher message is placed Unprocessed messages are marked out by bold font and underline Messages with the same priority are placed according to the time they were received After processing all messages are placed according the time they were received Several alarm windows can be opened at one time When sound signal is turned off it is turned off for all unprocessed messages But if there is at least one unprocessed message in the queue reminder sound signal ding is on Signal period is set in Options submenu If after turning off the sound a new message is received sound is turned on again If a message with a higher priority is received than sound signal is changed to the sound assigned for this new message Note Message priority is determined by its type see DB editors Program general settings System settings System settings window can be opened through main menu in the program general window Service Options Due to the fact that many of the settings affect program functionality it is recommended that they would be configured only by qualified personnel System settings window consists of 9 tabs which will be observed below WSC Options E 21 xl Groups Classes n air alarm Time This tab is designed to adjust time Time Sound Timeouts Signals Comments
41. dress Name object name Description object short description Date Time time when last message was received Status object status armed disarmed Event type type of the last received message LV object radio signal level Last message last object message physical address of the last repeater that transmitted message number of times message was repeated type of transmitted data expected time when security panel test message should be received TxAdr address of the transmitter installed on the object receiver number slot number address Account number of the panel installed on the object receiver number line number number GSMPhn GSM transmitter phone number Adr object address specified in the Address field of the Details tab in the object card Note Field order in the table by default is set same as in Visible fields option To change it you have to move cursor to the field header and by pressing and holding left mouse button move column to the preferred place To adjust field width place cursor on the right header border and after lt gt symbol appears adjust width by pressing and holding left mouse button e Font allows setting optimum font size and type and changing encoding e Freeze freezes all fields to the left of the selected Freezed fields will be fixed when table is scrolled e UnFreeze cancels
42. escription is given than information from this input is ignored R can take two values Y alarm event is added to Alarm List window not added This function will work only if Reminder timeout parameter in the window header has nonzero value E mail sending Every event for every zone can be automatically sent by E mail to the mobile phone pager or other E mail address To open mail editor just right click on the event description field and select Mail from the context menu Mail editor window will open PU I In the Target Address field you enter E mail address In the Target Subject field message subject ENT Mail editor E ENN xj xl Subject T arget Address x Target md Subject Opening Subject Office Liksnas 7 In the lower field message text When E mail is sent time when event was received by CU is added to it As you can see you can send E mail to three different addresses at a time To save information just press v button to delete Events that will be mailed are marked with 23 symbol in the M field Mail sending is made by an additional program that is not included in the default software package Described software version allows saving zone descriptions to the text file in the ZCard folder and load it to the object card in the future This is made using context menu that contains following items 1 to
43. ete event from Alarm List window R can take two values Y alarm event is added to Alarm List window not added This function will work only if Reminder timeout parameter in the window header has nonzero value To ease object entry procedure and decrease database size you can change part of the event code symbols Event field and or Control panel account Account field to In that case into event description Message are put any code that has any symbol in place of a To identify an event the description text are put for the code and for control panel account combination that will be replaced by the appropriate symbols from the event code see example below Number of 2 in the event code cannot be more than number of symbols in the event code but they must be positioned from right to left without any other symbols between them If there are need to assign to one of the codes programmed with a special description you have to enter this code as an additional line code 43 in the example Example of using when programming events Objects Details Zone Events TLF Events Work Schedule Hardware Notes _ _____ ___ T Message TERRENI ELS CE 012 0103 P Unregistred key usage H 012 0103 F FIRE alarm N E 1012 0103 4 B Alarm in zone E H 1012 0103 1 E Registration mode entry H 1012 0
44. g set period no test message was received from the device an alarm message No signal from object is created It is recommended to set Object Test time value a 5 10 longer than a real transmitter test period to compensate possible timer deviation If the value is set to O than test messages are not monitored Reminder timeout with this time period not restored alarm events from the Alarm list window will be repeated Repeated messages are marked with R symbol in the event description field see Alarm list information window If the value is to 0 than alarm messages from this object won t be repeated Mail allows sending an E mail when an event occurred This events are see picture 1 Object disarming at illegal time see Work Schedule 2 Object not armed see Work Schedule 3 Nosignal from object 4 No signal from transmitter WSC Mailing EU xj Target Address Subject signal In the Target Address field are entered desired E mail address In the Target Subject message subject In the lower field message text As you can see message can be sent to three different addresses In the Reminder message field you can insert any important information and if Enabled checkbox is active this information will be added to every sent message Settings opens an additional menu for choosing program reaction for different types of events As you can see the p
45. icture for every event type 2 there are 4 checkboxes Filled checkbox means that appropriate reaction is active empty ignored Corresponding reactions are shown on the top of the window 1 Alarm alarm window 15 initialized 2 Sound appropriate sound signal is activated If an alarm window is opened than sound signal is played as many times as set in the Sound repetition field see System settings If no alarm window is initialized than it is played only once 3 Arch event recording into archive 4 List event displaying in the Event window For all types of alarm messages all this functions are always active You can save the most recently used setting by pressing the SetAsDefault button In the future you can load this setting by pressing Default button This setting also is used when creating a new object in the database Radio list of identification parameters for the device that uses radio communication channels Consists of 4 parameters 1 Tx Address physical device address 2 Channel receiving channel number receiver See Receiver settings 3 Slot Slot number receiving channel from which information should be received 4 Device type allows choosing type of described device transmitter Tx repeater Rx Phone list of identification parameters for the device that uses wire communication channels phone lines Consists of 3 parameters 1 Account control panel acc
46. ing just press the symbol in the upper right corner of the window Archive selection example is shown on the picture below gt Archives Miel 10 SIA 10 10 2001 e X pae re To lEvume DATA 1110 10 01 171030 10 5 1000 SIA DRBE Arming Armed 011122 100000030 11010 01 171031 10 6 1000 SIA Troubles Armed 0111222200000030 10 10 01 171014 10 6 1000 SIA DRBC Dis rming Dis med 0111228100000030 101001 171016 10 6 1000 SIA Troubles Dis amp med _ 0111222200000030 11010 01 231706 10 6 1000 SIA DRBC Troubles Distmed 220 0000000000000038 10 10 01 231752 10 6 1000 SIA Restore Distmed 220 Ok 0000000000000030 1110 10 01 231753 10 6 1000 SIA DRBE Troubles Distmed Ill 0111222200000030 1110 10 01 23 18 00 10 5 1000 SIA DRBE Arming Armed 011122 100000030 11010 01 231801 10 6 1000 SIA Troubles Armed
47. ing report forming functions Header font selection Made using context menu by Header Font command When selected a standard font adjusting window will appear There you can select font font size color etc Text font selection Made using context menu by Font command All is similar to previous paragraph Field formatting is made by adjusting width for every column To adjust column width you have to move cursor to the column border in the window header left click and hold mouse button and move it to the necessary position button Working with CU4000 central unit log file CU4000 central unit log file is a text file where all the messages are saved regardless whether an object is added to the DB or no Moreover there are saved all messages from every transmitting session duplicated repeated etc Since every message contains information about signal level route repeating number transmitted data etc log file analysis allows having a clear view on the network efficiency log file will form only in case if there are a maplog folder created in the program main folder created by default when installing Every log file contains information for ten days File name has the following structure YYYYMM_D log Where YYYY year MM month D decade number For example 200911 2 log is a file created on the second decade of November 2009 To ease work with log file there are a special utility LogView see
48. ings System events Editor opens receiver system messages editor For more information see DB editors Sound Off turns off sound signal that is started when alarm message is received Not sensual list list of objects and zones that was marked as Not sensual Problems list list of all problem notes made by operator About submenu Contains information about program version and selected CU4000s serial number and software version Alarm list information window Can be opened by pressing appropriate button on the control panel and contains a list of all alarm messages that wasn t restored Also in adjusted for every object period of time Reminder timeout in DB editor alarm windows for each message are opened Repeated message is shown with R symbol before message description All messages can be sorted by number or by event type z gt WSC Alarm list oe Panic 111 1006 27 11 2003 11 20 15 27 11 2003 11 30 14 Troubles 1011 27 11 2003 11 20 22 CPRC 6D 1 27 11 2003 11 30 21 Visible Fields Font Delete If needed messages can be deleted by pressing Pelete button You can also add and remove information fields change their size and order and choose font Settings menu is opened with right mouse button Note To add alarm message to Alarm list window in DB editor field
49. installing the program launch it using WSC icon in Start menu You ll have to enter user Login and Password After installation only one user is registered in the program Administrator who has full access to all program functions Login sys Password sys Administrator Login is fixed and cannot be changed but it s strictly recommended to change the password Interface Program interface has a large amount of adjustable parameters that allow every user to reach maximum work comfort Interface structure consists of general Monitoring window and few secondary windows General window is shown Pic 1 Windows Security Commander Monitoring Utilities Archive Service About ALARME E ee ccs IL 240 57 peste 3 2 BE 22 EN O Backup 0 8454 signall 305 No signal 12 59 21785 1 Jelgava 8 44 27 Arming 505 Close by user3 1 77 7 Home Sweet Home 75929 Event Sys Transmitter 1 7 136 on air Il 1 735 7 CU4000s 17 43 07 Event Sys Transmitter 1 7 136 on air 1 7 1365 7 CU4000s v 72748 Event Sys Transmitter 1 7 1536 on air 1 7 135 7 CU4000s 3 6 47 10 Event Sys Transmitter 147 136 on 17136 7 CU4000s 64340 Disarming 511 Open by user 3 Part 14 1999 4 SIA KORTEKS _ wv 6 14 10 Event Sys Transmitter 1 7 136 on air Il 4 7 36 7 CU4000s d v 6 02 38 No signal 80 No sig
50. l panel manually Table of recommended codes is attached to the IF 1 2 interface module manual Not described event will be displayed in the following way Account 1234 Event 15 IF 1 4id interface module RT4 5se id transmitter Using this interface module you can read information from any control panel that has tlf communicator and supports Contact ID transmission format see IF 1 4id user manual Example of event programming for this situation is shown on the picture below Objects Details Zone Events TLF Events Work Schedule Hardware Mates 3 123456 113377 1 24 313377 H 3 123456 1134 B 1 E 3134 H 3 123456 1135 B 1 E 3135 3 123456 113777 1 313727 3 123456 1140777 1 E 3140272 M 3 123456 1150777 T 1 24 315077 Y 3 123456 1151 T 3151272 Y 3 123456 1154 T 315427 Y 3 123456 1158 T 315877 Y H3 123456 T 3159777 Y l4 1 5 P Pamc T Trbl w PwH 4 Arm D DAm E Event 5 Tst
51. level retranslation routes etc adjustable program interface language selection visual display of object status information received information and operator actions archiving vide options using databases and archives periodical control of database status periodical database backup database encrypting using double password fast and easy access to any object information possibility to add an image to object card possibility to create default object configuration library possibility to receive and control object telemetry information general and additional work schedule for every object efficient control of not restored alarms periodical reminding of not restored alarms automatic control of transmitters and security panels test messages report generating and printing object search using specified parameters object sorting using status group class and event type possibility to send messages to client s E Mail mobile phone pager three levels of access to program options receiver system functioning control time synchronization between PC and receivers control of communication with receivers GSM modem support and possibility to receive messages from GSM transmitters Current manual is made to acquaint user with basic principles of software use Installing and launching the program To install the program launch Setup exe file from the installation CD and follow the instructions After
52. nal 04 00 17014 7 Test of Hopper 10 3 12 59 Nosignal 82 No signal 04 00 171012 7 Test of Hopper 12 11 47 13 signal 29 signal more then 3 days 1 4 R250 4 First frequency system repeater 9 Jurmala 4 14713 No signall 7 signal more then 3 days 2 5 R7 5 Koblenz s repeater 121 5459 signall 82 signal 08 01 1012 Test of Hopper 12 M 21 06 24 Event Sys Transmitter 1 7 136 on airl 17356 7 CUA000s E eNotes a 1 Histo tf Details F Problem E E SM 54 E 2007 23 09 14 24hour Repeater Nr 4 TEI EN 4 JAC RESTORE 55 UURS 14 02 2007 5 57 09 24hour Repeater Nr 5 KARAVELA _ 2 0 5 AC RESTORE 5 56 1TIRB 14 02 2007 4 13 20 24hour Repeater Nr 6 lerikju Unijas 2 0 6 AC RESTORE a 57 Inactive Repeater Nr 7 milgravis 0 0 1 7TIRS 13 02 2007 21 55 42 24hour Repeater Nr 8 Kleistu 2 Imanta 3 0 8 JAC RESTORE 5 TIRS 14 02 2007 217 22 24hour Repeater Nr 8 Hipokrata 2 Gailezers 1 0 8 Tamper RESTORE 50 11 7 8610 14 02 2007 3 09 27 24hour Repeater Nr10 Dzintars 2 0 10 RESTORE B1 11777611 14 02 2007 7 19 37 24hour Repeater Nr11 Hotel RIGA 2 0 11 AC RESTORE B2 17812 14 02 2007 3 55 25 24hour RepeaterNr12 Pr Kurzemes 124 2 0 112 AC RESTORE 53 1718613 14 02 2007 3 20 26 24hour Repeater Nr13 Maskavas Sardze un Ko 2 0 13 Ac RESTORE 64 17814 14 02 2007 9 14 17 24hour Repeater Nr 14 Ganibu
53. o the last object button add object button delete object X button cancel changes button convert all letters in the object card to capital letters button Copy object When copying data from the following tabs will be copied Zones Events TLF Events and Work Schedules button save changes button allows attaching to the object card an image containing additional information about object or it s location Supported file formats gif bmp jpg jpeg emf wmf There is a special folder named pict to store those files but they can also be located anywhere on the hard drive Transm test time time determining transmitter or repeater test message period In case if during set period no test message was received from the device an alarm message No signal TIME is created where TIME time during which there was no test message If there were no signal for more than 3 days No signal more then 3 days message is created It is recommended to set Transm test time value a 5 10 longer than a real transmitter test period to compensate possible timer deviation If the value is set to O than test messages are not monitored Object test time time determining control panel test message period Can only be used in RS4000 system using transmitter with communication interface see RT4 5se user manual If used in the Events tab must be entered an event with a S type test In case if durin
54. operator when he presses the Details button in the alarm window or on the information panel in program main window Zones tab This tab is designed for describing signals from the inputs zones of transmitter repeater or zone expander Objects Details Zone Events TLF Events Work Schedule Hardware Mates Zone M T Zone swich 0 1 Zone swich 1 0 5 1 Burglary alarm R Burglary restore H dd N4 D DisArming Arming N T T Battery low R Battery OK H e p 77 F Fire B Bur T Trbl W PWR A Arm D D m R Restore E Event It consists of the following fields object number This is an information field and can t be edited P can take 2 values zone is monitored permanently P zone is monitored only if object status is Arm It s not recommended to often use this function due to the possible loss of information Zone Zone number Number of the transmitter s described input If you don t use the zone you don t have to describe it In case if there are an event on the undescribed zone it is considered as an E Event type and displayed in the following way Unspecified zone switch with a list of activated zones T event type For every event described in the 0 1 and 1 0 fields you have to assign a type Every type is marked with it s own color both in the editor and in the program information fields This allows significantly ease o
55. ount or GSM transmitter PIN code Alarm Sound Arch List we wf 0 Cancel Default ie Ee Set as default 2 Channel receiving channel number receiver See Receiver settings 3 Line number of the line that is used to receive information 4 n case if in the Line field was selected GSM parameter is information is transmitted using GSM network than the fourth field Phone will appear There you have to specify phone number of the SIM card that is inserted into a GSM transmitter RT4 5gc Phone number must be entered with the international code 37 1 etc Editor menu that contains a list of functions to switch to general tabs and fields and appropriate hotkeys Details tab This tab is designed for more specific object description and to specify contact persons Tab appearance is shown below Address Ziupes 000 EE 3775053 City Figs Group n3 Fax 371 7505604 7 ofice zp 0 Persons Name Moreshkhow Jury Post I1 c Address o os Phone As you can see there are fields to specify object mail address it s informational address and to assign object to a group and category see System settings Also you can specify a key word to identify client if he is calling to the central station All this information can be seen by an
56. perator s information comprehension There are the following event types 1 P Panic alarm event Received when a panic button is pushed on the object F Fire alarm event Received when a fire alarm goes Bur alarm event Received when burglary alarm goes T Trouble alarm event Describes different object malfunctions tamper alarm low battery etc 5 Object arming 6 D Disarm Object disarming Those events are usually describe two states of one zone Every described object can have only one zone with D or A event type If object doesn t have zones with these events than it s status will always be Arm 7 Restore Zone restore Used to describe zone normal state for 1 4 event types 8 E Event neutral event To change event type use the space key or press corresponding letter key Zone switch 0 1 and Zone switch 1 0 Event descriptions In each of these fields you have to describe an event for each of the zone states So in Zone switch 0 1 field you describe an event that corresponds zone switching from closed state to open and vice versa If transmitter inputs are loaded to or you use RS1000 transmitter than descriptions for closed and open states are switched to opposite For system events low battery and AC lost Zone switch 0 1 will always be alarm and Zone switch 1 0 restore If input number is added to the list but no d
57. ransmitted using radio channel it is possible to change part of the symbols in the event code Event field and partition number Partition Nr field to In that case into event description Message are put any code that has any symbol in place of a To identify an event the description text are put E for the code and for partition number combination that will be replaced by the appropriate symbols from the event code see example below Number of in the event code cannot be more than number of symbols in the event code but they must be positioned from right to left without any other symbols between them there are need to assign to one of the codes programmed with a special description you have to enter this code as an additional line Example of using when programming events for Sur Gard MLR2 DG central unit default format Objects Details one Events TLF Events work Schedule Hardware Mates d 15 T Failure 16 N d R 15 R AC Restored N d Al T UPS Low Battery 18 N a 18 R UPS Low Restr N A 19 T CPM Master Fail d T Internal communication error H A DU T CPM Reset N a AF T Line Card E Absent RE N d Line Card Restored N 1 T 10 T Faulty Data Received on Line Card l4 4 7 5 P Panc T Trbl PWA A Arm D DArm H Hestare E Event 5 Tst
58. s No function not allowed Yes function is fully allowed R O function allowed in read only mode cave to file Itilities a Receiver system events editor System events are events that describe status of the receivers central units connected to the program System event information is loaded into DB when you choose a receiver in the settings menu see settings Editor is designed only for it s editing You can open editor using main menu Service System events Editor Editor interface is the same as object database editor but only lacks parameters that are not used to describe receivers Description of events from CU4000 and RR1000 central units is made in the Zones tab other central units are described in the TLF Events tab Event description rules are the same as for the object event description On the pictures below are shown fragments of event description for CU4000 radio and MLR2 DG tlf central units WSC Editor Editar E J Mame cu4000s Description Reminder timeout 00 00 Mail Settings Objects Zone TLF Events Mates Me Eme e Tr N T Slot 3 fail Slot 3 N N Slot 4 fail R Slot 4 Ok N 30 T Slot 5 fail Slot 5 N N 3 Slot 6 fail Slot 6 Ok N N 32 T Slot 7 fail Slot 7 N H 33 T Loss communication with CU4000s Restore communication with CL ADOOS H
59. synchronization between PC and CU4000s Central Unit so You can choose synchronization source Source of synchronization and it s period By default it is set to synchronize from PC with a 1 hour period In the DOE UE DE example shown on the picture synchronization is made from PC with 10 minute period ar ERANT 5 Sound In this tab you can adjust the following parameters Sound device selection of the device that _ will play the sound signals It can be sound Groups Classes On air alarm card or PC speaker Also sound can be Time Sound Timeouts Pictue Signals Comments completely turned off um P y PE Sound repetition 10 Sound repetition determines a number of Y 0070 Alarm reminding 5 times the sound signal will be repeated when alarm window will appear If the value is Sound card set to 0 than it will be repeated until it s Tag o soun turned off by the operator Alarm reminding determines how long it will take to form a reminder signal if there are unprocessed messages Timeouts In this tab you can set a period of time ix during which all identical messages from one object are T considered one message case they are received row and a program reaction when receiving a duplicate Timeout for zones mm ss fo1 00 message Mentioned period is set independently for
60. t so this section will describe programming main principles and give some general advices To describe an event the following fields are used NR object number This is an information field and can t be edited Partition Nr partition number If the control panel has only one partition and used transmitting format doesn t obligatory need partition number than this field remains empty Event code must contain event code that is received from control panel For different communication formats it can have different size and structure M M E mail sending Filled exactly the same as in the Zone tab Event type Possible event types are listed below 1 P Panic alarm event Received when a panic button is pushed on the object 2 F Fire alarm event Received when a fire alarm goes on 3 B Bur alarm event Received when burglary alarm goes 4 T Trouble alarm event Describes different object malfunctions tamper alarm low battery etc 5 W Pwr 220V circuit control Events of this type are acting the following way when alarm is received program acts according to settings made for this event type in Settings window If no restore is received for this event in a period specified in the Reminder timeout field than an alarm window will be opened again automatically 6 A Arm object arming 7 D DArm object disarming As opposed to zone programming when programming
61. t by Numbers opens filter window to form archive extraction using object numbers in DB Sort by Tx Address opens filter window to form archive extraction using object s transmitter address Sort by Accounts opens filter window to form archive extraction using object s security panel Forming archive extraction for a objects you can use any of these functions For additional information about archive extractions forming see Working with archive Sort by Status Opens additional window with the list of objects that has specified status armed disarmed For additional information see Working with archive Service submenu Consists of the items to configure program general functions User info displays information about current user name login and access level It s not possible to change parameters in this window Refresh refreshes object window information Cursor Jump controls cursor placement on object function There are three modes gt None cursor isn t placed on an object gt On Alarm cursor is placed on an object if alarm message received from it gt Events cursor is placed on an object if any message followed by sound signal received from it Receivers Settings opens window for receiver channels parameters configuration For more information see Receiver settings Options opens window for program general parameters configuration For more information see System sett
62. t the following Time 150000 parameters Period days sets a time period of automatic DB Repairing function executing md Time DB Repairing function executing time Renewal of structure checkbox determines whether information in object table will be updated after DB repair or not Reload channels checkbox determines whether connection with receivers will be reinitialized after DB repair or not DB Backup initializes backup of DB data WSC Backup config E 3 x Backuping schedule allows setting SSS Path ESProgram Files Korteks WS CN automatic periodical launch of Backup function and setting backup directory You can the following parameters Period days Path determines the path to the folder aS 12 00 00 where the DB backup copy will be saved Period days sets a time period of automatic DB Backup function executing Time DB Backup function executing time Reload channels checkbox determines whether connection with receivers will be reinitialized after DB backup or not Reload chanels Change system password allows to administrator password default sys It is recommended to change administrator password right after installing the program because it is also used for data encryption Archive submenu Consists of the items to form archive extractions using given parameters Note 1 Note 2 Sor
63. termined by zone load If zones are loaded to default zone open state is transmitted as 1 and closed state as 0 If zones are loaded to 0 vice versa When using zone expanders the first and the second zones are not used and not programmed Zones are assigned for the expander according to it s address and are the following 9to 16 for address 0 17 to 24 for address 1 25 to 32 for address 2 33 to 40 for address Expander zone programming is the same as transmitter s When connecting one transmitter to a few objects it s zones are divided between them Programming process is the following 1 Create an object with N number and transmitter address X 2 Program object parameters and zones that assigned to this object 3 Create an object with M number but leave transmitter number as X 4 Program object parameters and zones that assigned to object M This procedure can be made with every transmitter type Number of objects assigned to one receiver is only limited by the amount of zones including zone expanders One zone cannot be used on two or more objects Example of two objects assigned to one transmitter is shown in the picture below zones that assigned to other transmitter are grey colored Objects Details one Events TLF E vents Work Schedule Hardware Mates we Ese Burglary alarm Burglary restore 2 T Pannel trouble Pannel
64. the last ten messages from selected object Hot key Font e Picture display of the graphical information about selected object Hot Freeze key Ctrl P e Notes display of the operator s notes for selected object Hot key _ Editor e Details display of the advanced information about object and contact persons Hot key Ctrl D Search e Hardware display of the information about hardware installed on _____ object Hot key Ctrl A aisi dd e Problem allows operator to leave note about a problem occurred on Filter On Ctrl F the object All notes are added to list where they can be processed and Filter OFF printed Hot key Ctri Alt B e Archive opens filter that can form archive selection for selected object Maintenance see p Working with archive Hot key Ctrl B mem er Msg Note Only Latin register can be used for Hot keys The following menu options are used to adjust window interface e Visible fields determines fields that will be shown in the table To show the field you have to select it in the list that appears when selecting this Show option The following fields are available for display in the table Nr object number in DB Test time expected time when transmitter test message should be received 10 source of the last message receiver number slot line number device ad
65. to the fact that you need an authorization to enter the program you need to be able to assign a login and password for every user and determine their access permissions to the program functions Full access has only administrator login sys fixed Administrator password sys by default can be changed using main menu Utilities Change system password Described editor is designed to create and edit user datebase You can open editor using program main menu Utilities Users User DB Editor Window appearance is shown on the picture To add a new user to the database you need to Press symbol on the lower panel Empty row will appear Enter login 5 symbols max and real name of the user into log and Name User DB editor Xx Operator _ C Manager E NE f Supervisor fields _ Choose access category in the window right side Operator Manager a Supervisor enter password press Password button Current password window will appear If you are entering new password press OK if changing already existing enter it and press OK In the next windows you will have to enter new password and confirm it save changes press To cancel changes press X To delete user from the DB press delete user you don t need to know it s password assign program functions
66. tons to open general information about object and contact persons Information Displays information selected by corresponding button on the Information Panel Operator comments Allows operator to leave a comment about event his actions operative group actions etc You can also use default comments see Program Main Menu Comment list opens with F2 key To add comment without opening a list press Ctrl comment number For every event operator can add few commentaries by pressing Wait button after adding each one In this case alarm window is closed and message in Event Window is marked by symbol add next comment you must do double click on this window and Alarm window will open again After adding last comment press Ok After that message is processed and placed into archive with all of the comments For every comment in archive is added time when it was created Control panel First three buttons History Hardware Picture allow to receive additional information about object that sent this message see Object Window Sound Off button allows turning off sound signal without closing Alarm window Hot key F5 Wait button allows delaying final message processing until additional comments are added Show button allows displaying object on a map in the Tracking software Ok button processes message Hot key F12 In case if next message is received before previous is processed in event window is formed unprocesse
67. tor Access Manager Access Supervisor Access opens access level adjustment window Administrator access level has full access to all program functions Access adjustment window has following fields 1 Exit ability to quit program 2 Archive view ability to view archive 3 Archive print ability to print archive 4 Object edit ability to edit object DB 5 Rec settings ability to configure receiver ports 6 Options ability to configure parameters in Options menu 7 Cursor setting ability to configure cursor jumping mode for object window 8 Operator configure ability to configure operator access level 9 Manager configure ability to configure manager access level 10 Supervisor configure ability to configure supervisor access level 11 Windows config ability to configure window parameters 12 Max on alarm allows to maximize program window when message is received if it was minimized 13 Save to file ability to use save to file command 14 Utilities ability to use program functions in Utilities menu For every function are possible three access levels 1 No function not allowed 2 Yes function allowed 3 function allowed in ReadOnly mode DB Repairing initializes search and repair of errors in the DB WSC Repair config X Repairing schedule allows to UM automatic periodical launch of Repairing uem function You can se
68. will be shown in the table To show the field you have to select it in the list that appears when selecting this option The following fields are available for display in the table S Current message status There are four statuses 1 automatically processed 2 processed by operator vw 3 not processed 4 delayed Date Time time when message was received Event type type of received message Nr object number in DB Status object status armed disarmed Message message text 10 message source receiver number slot line number transmitter address security panel account Slot slot line number of the receiver that received message RNum number of transmitter that have sent message Name Object name Adr object address specified in the Address field of the Details tab in the object card Also there are command to open object editor e Editor opens object editor Hot Key Ctrl E Not sensual when object is in this mode all messages from it are ignored for specified period of time e Maintenance when object is in this mode all messages from it are not followed by sound signal and alarm window Usually used not to distract an operator when object is under maintenance e Show displays object on a map in the Tracking software To do so it s necessary to create in the Tracking software a static object with the same number as in WinSC Inform
Download Pdf Manuals