1. Contact Open Contact Close For the 4 possible scene this number allow to initialize the status associated to previously selected scene number avoiding to execute the store scene procedure If the store scene is done this value is overwritten Disabled This parameter enable disable the output channel from storing value received from the bus if this parameter is set to disable the value associated are set only by the parameters Initial value Scene lt X gt and cannot be modified without a ETS download Learn Scene e e When a scene is recalled the output channel behaves in the same way as it would have received a telegram 0 or 1 on the Output x Relay Command communication objects this means that if the scene always trigger a NOT TIMED command e After a ETS download the device assumes the value of parameter Initial value Scene lt X gt as a value in memory for the corresponding scene and overwrites previous memorized scene positions KNX 25 32 IO32DO1KNXFIO1040002 DOCX IO32DO1KNX Product Handbook 15 4 Priority table for Output 15 5 Behavior of output on voltage failure recovery and commissioning Behavior on bus voltage failure Parameter Relay Position on Power down On failure of bus voltage behavior of output is driven by the parameter Behaviour on power down Parameter Relay Position on Power up Behavior on bus voltage recovery l On bus voltage recovery
2. Valve Position when relay is open parameter P anim KNX 28 32 IO32DO1KNXFIO1040002 DOCX 17 Output Configuration for shutter Outputs can be configured in pairs for the management of roller shutters and blinds Out Function Terminals Out Function Terminals OUTTA up 12 OUT2 w down 374 KNX PARAMETER SETTINGS Venetian Select Venetian if the shutter has louvers select shutter if it is a roller shutter Shutter Type Shutter travel time sec 0 3000 This parameter set the total travel time for shutter Extra Time for shutter 15255 travel sec This parameter indicates the number of seconds to add to the travel time for all the movements that bring the shutter completely up or down Stop time between 2 shutter movements Set the minimum time for the shutter to stop from passing from a movement to another Absolute position Same When enabled this parameter shows 2 communication object SHUTTER POSITION OBJECT and VALUE SHUTTER POSITION OBJECT SHUTTER POSITION a positioning control command can be sent to the device using a percentage value the value is relative to the percentage of closure 10 50 etc 0 shutter totally up shutter totally down VALUE SHUTTER POSITION through 1 byte telegram the information on the current shutter position can be sent the value is relative to the percentage of closing Eelectron SpA
3. Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 IO32DO1KNX Product Handbook on off control in heating mode THE MEASURED TEMPERATURE RISE ABOVE THE VALUE OF SETPOINT DIFFERENTIAL THERMOSTAT SENDS A OFF COMMAND TARGET SETPOINT 4 DIFFERENTIAL REG LATION DIFFERENTIAL TARGET SETPOINT THE MEASURED TEMPERATURE DECREASES BELOW THE VALUE OF SETPOINT THERMOSTAT SENDS A ON COMMAND on off control in cooling mode THE MEASURED TEMPERATURE RISE ABOVE THE VALUE OF SETPOINT THERMOSTAT SENDS A ON COMMAND TARGET SETPOINT REG LATION DIFFERENTIAL i TARGET SETPOINT 5 0 DIFFERENTIAL THE MEASURED TEMPERATURE DECREASES BELOW THE VALUE OF SETPOINT DIFFERENTIAL THERMOSTAT SENDS A OFF COMMAND KNX 12 32 IO32DO1KNXFIO1040002 DOCX 1032D01KNX Product Handbook PWM control in heating mode 9 2 On off with PWM control 100 OFF TARGET On off with PWM control is an algorithm that reduces n SETPOINT the effects of hysteresis around the set point value by o i i adjusting the controls on the values ranging from 0 to lt ia lala naa aia gt 100 where 0 means control off and 100 means 3 _ 40 ON 60 96 OFF S maximum control action OS p O
4. Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook 17 1 Delay on opening and closing These parameters can be used if you want to drive double doors In this case one door must start first in opening and the other must start first in closing KNX PARAMETER SETTINGS Disabled Delay on move up Enabled Enable disable a delay between the receipt of an up command and the start of the movement 5 sec Time for Delay on move up 2 ec 30 sec Values for the delay Disabled Delay on move down Enabled Enable disable a delay between the receipt of a down command and the start of the movement Time for Delay on move down Values for the delay OPENING ee a Po CLOSING 1st TO OPEN 1st TO CLOSE KNX PARAMETER SETTINGS Step time for louvres 1 180 movement x 100ms This parameter selects how long the movement for every step of the louvers is visible only if shutter type is Venetian range from 100 ms to 18 sec P ames KNX 29 32 17 3 Additional Functions IO32DO1KNXFIO1040002 DOCX 17 2 Louvers automatic movement If the channel is configured for Venetian control Parameter Shutter Type Venetian it is possible to enable an automatic movem
5. on the bus with value 1 As soon the temperature sensor works good again a value 0 is transmitted To correctly manage the use of internal and or additional refers to the following possible configuration modes Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook CONFIGURATION MODE 1 Internal probe Additional probe Disabled Ratio between probes NA 100 internal Measure of temperature is performed every 60 seconds if the temperature probe is disconnected or In short circuit the control action is interrupted and the controlled actuators are switched off probe disconnection short circuit out of range measurement Obj 21 Actual temperature transmits 0 C Obj 39 Temperature sensor alarm transmits 1 CONFIGURATION MODE 2 Internal probe Additional probe Received by bus Ratio between probes 10 to 90 Measure of internal temperature is performed every 60 seconds the additional temperature is read every 60 considering last value received on Obj 22 Additional temperature The value of temperature sent on the bus is the pounded average between internal and additional probes value If the additional temperature is out of range or the surveill
6. you can set the thermostat in one of the following modes OFF ECONOMY STANDBY COMFORT each mode is associated with a setpoint set by a ETS parameter OFF mode is associate to setpoint antifreeze in heating mode and high temperature protection in cooling mode HVAC MODE object automatic heat cool Behaviour for this value of parameter Thermostat control mode is the same as above described but the switching from heating to cooling mode and vice versa is automatic With this setting it is necessary to set an insensitive zone as in parameter Dead zone Whenever temperature becomes greater than Setpoint comfort heating Dead Band 2 active control is cooling when temperature becomes less than Setpoint comfort cooling Dead Band 2 active control is heating SETPOINT Heat protection Off elica ii Economy Cooling licia D Standby Cooling gem eee dee COOLIN Comfort Cooling s usesssssseieuieitds assesses oem iniecit DEAD BAN Comfort Healing itte et t Dni tte 5 Z Standby Heating sec ustesuticuvietand Totti aceti tte LLI I Economy Heating AE E Antifreeze Off E ead oad EE EE E AE Rea COMF STBY ECO OFF HVAC SETPOINT COMFORT object SETPOINT STANDBY object SETPOINT ECONOMY object These 2 byte objects are used to set the setpoint values for COMFORT STAND BY ECONOMY mode Whenever change the setpoint are in saved in memory After do
7. Disabled Sending State Telegram When status changes On request Disabled Status is never transmitted ad related communication object is not visible When status changes Status is transmitted every time the relay switch changing his status from ON to OFF or from OFF to ON On request Status communication object is available and updated when status changes but the telegram is not transmitted Read propriety is enabled Telegram 0 when Telegram Value for status relay is open sending Telegram 1 when relay is open This set the value you want transmit when relay is open or close and therefore the valve is open or close according to the parameter Valve Position when relay is open Function Enabled It is possible to enable an automatic switching valve function useful when there are long periods of inactivity for example during the summer season If this function is activated you can select how long can be the period of inactivity see parameter Anti Locking Valve Activation Period before that the valve performs a switching ON and after 5 minutes a switching OFF Anti Locking Valve 3 days Activation Period 10 days Determines the maximum period of inactivity allowed Disabled Lock Function Enabled When lock function is enabled it allows switching the relay in a defined state and forcing it to maintain this state even if the it receives 1 bit or 1 byte control commands Valve Open Behaviour on p
8. Speed Tar2 regulation differential in heating for V2 Speed Tm Actual measured temperature Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 VALVE ON VALVE OFF VALVE ON VALVE OFF 1032D01KNX Product Handbook Control logic for a 3 speed fan coil in cooling When temperature decreasing V3 ACTIVE selce saazi f TOR TEMP SP Tdcv1 Tdcv2 V2 ACTIVE REGULATION DIFFERENTIAL Tdcv2 EOD NEERUNUNE ets ee gc See ns e TEMP SP Tdcv1 REGULATION DIFFERENTIAL Tdcv1 V1 ACTIVE TEMP SP Tsp V1 ACTIVE i REGULATION DIFFERENTIAL Tdcv1 V Q TEMP SP Tdcvi VENTILATION OFF Tm When temperature increasing V3 AMINE d Tm Fr TEMP SP Tdcv1 Tdcv2 V2 ACTIVE REGULATION DIFFERENTIAL Tdcv2 MM QUEE SENE TEMP SP Tdcv1 V1 ACTIVE REGULATION DIFFERENTIAL Tdcv1 TEMP SP Tsp VENTILATION OFF REGULATION DIFFERENTIAL Tdcv1 j W_ TEMP SP Tdcv1 VENTILATION OFF Where Tsp Target setpoint temperature Tdev1 regulation differential in cooling for V1 Speed Tdev2 regulation differential in cooling for V2 Speed Tm Actual measured temperature KNX 14 32 IO32DO1KNXFIO1040002 DOCX 9 4 Fan coil control or generic continuous control Logic a
9. Temperature probe failure out of range measurement i 15 11 Behavior of Thermostat on voltage failure recovery and commissioning 0ccccsseeeeeeeeeeeseeeeeeaeeeeeeeas 16 12 CUOCO MORET T T 17 12 1 Remote control configuration e 18 12 2 Activan ON DOSS areata 18 12 3 ole T E EE A EE EEE EE E EEE EEE EN 19 12 4 Commands Segue a1 61 gt S erener a a oe ee ee ee eo ee ee i Su SII ee 19 12 5 Special Function for buttons 5 6 7 8 19 13 COUT ONTO O ee a ie O ale resi 20 14 Genenc load Control eeii na ig EE r nta 20 14 1 Function ON OFF srei sce ee eee oe ei 21 14 2 TATU TAC COINS scaldi cacca 21 14 3 Function ON OFF nupe r 21 14 4 Function ON with delay timing OFF 22 14 5 ON FF vs Timing FUNCHIONS e 23 15 Ou tpurAdditional Fanc UGN me T E OO ETE 24 19 0 Log FUNCION M NEU T T T m E 24 15 2 EOC UI e p mm 24 19 9 ocene FUNCION NENNEN 25 15 4 Prioliiy table tor UN OG E L 26 15 5 Behavior of output on voltage failure recovery and commissioning 26 16 Electric valve COMMON E E 2 16 1 Main Parameters i 2f 16 2 Kore ADi eiD g MEREREHE 28 17 Output Conf
10. mode waiting for a unlock telegram in order to become active Note that even if the shutter channel starts with lock function active it does not go automatically in the position defined by the parameter Shutter Position when Lock is Active avoiding to have automatic and unexpected movements when the power returns after a black out 17 6 Alarm Function Alarm function must be activated if the shutter has to be controlled by weather sensors typically rain and wind sensors The sensor must send telegram O if no alarm is active ad telegram 1 if the alarm becomes active When shutter has the alarm function active goes in a defined position and cannot be moved except with if the lock function became active for the time the alarm is still active KNX PARAMETER SETTINGS Supervision Time for 1 120 min Alarm min This parameter selects how long is the supervision time for the alarm function If this time is set for example to 30 min the shutter need to receive at least once in 30 min a telegram from the sensor even if the telegrams means no alarm It this not happens the alarm became active lack of supervision and need to receive a no alarm telegram to reset For this only sensor with cyclic sending can be used and we strictly recommend set the supervision at least double the cyclic sending period Move Up Move Down Stop no movement Shutter Position when Alarm is Active This paramete
11. scene command is avalable KNX PARAMETER SETTINGS Number of the scene Scene Number 0 63 This parameter sets the value of the scene you intend to recall one per channel Remember that output devices i e actuators etc generally can manage several scenes each identified by a value that varies from 0 to 63 therefore is important to set this parameter correctly and matching the number set on the actuators 12 4 Commands sequences The function allows you to associate the action of pressing the remote control button a single sequence of different commands on the bus The sequence consists of 2 commands which can each be sized as 1 bit or 1 byte you can associate different commands to each element of the sequence or decide to send commands only on one of the two events The waiting time between a command and the next is fixed in 1 second Each object communication can be connected to a different group address For example it is possible to define a sequence Command on Command on Com and short press edge edge 0 to a dimmer 1032D01KNX Product Handbook 12 5 Special Function for buttons 5 6 7 8 Buttons 5 6 7 8 can be configured together to implement a single special function Special function available are e Dimmer e Shutter e HVAC Mode e Manual Fan Coil d r m js gt 9 O fo MEN 9 5 1O B X e IRN P 8 O DIMMER O hs E Button 5 Light ON But
12. the bus blocks the shutter in a specific condition when a lock on command arrives this state is kept until a lock off command is received any command Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook received during the period in which the block is activated is not executed e ALARM FUNCTION this function allows linking the shutter channel to a rain or wind sensor to protect it from damage e e This function if enabled requires the sensor linked to send cyclically a telegram even if the alarm is off If the shutter does not receive any telegram for a defined time see parameter supervision time for alarm it goes in the alarm position as if it would have been received a alarm telegram 17 4 Scene Function When the scene function is enabled a communication object named lt Channel x gt Scene becomes visible It is possible to send to the device two possible commands e recall scene is a command to create a specific position of the shutter e store scene is a command to learn and store the current position of the shutter in the moment the command is received and then reproduce it once the recall command is received It is possible to store a maximum of 4 ou
13. 14 1 Function ON OFF Function ON OFF is always available through communication object Output x Relay Command Behavior of the relay set to NO and NC when activation telegram is telegram 1 Telegram 1 1 NO is closed NO is open l Contact type NO NO is closed NO is open Contact type NC Behavior of the relay set to NO and NC when activation telegram is telegram 0 Telegram 1 1 NO is closed open l Contact type NO NO is closed I I I I I NO is i I NO is open Contact type NC Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook 14 2 Timing Functions Its always possible to manage for each relay on off commands and timing commands in order to select if switch it on off for indefinite time or with timing function Timing function is activated by receiving a command on the communication object Output x Relay Timing Command Two possible timing fun functions e ON OFF with delay it is possible to set a delay between the reception of a telegram and the switch of the relay for both telegrams activation and deactivation e ON with delay timing OFF it is possible to set a delay betwee
14. 2 Setpoint comfort cooling STANDBY OBJ 33 Setpoint standby cooling ECONOMY OBJ 34 Setpoint economy cooling COMFORT object ECONOMY OBJ 29 Setpoint economy heating ADDITIONAL TEMPERATURE object COMFORT object 1 bit size is visible only when Thermostat control mode parameter is selected with the value HVAC MODE When a telegram 1 is received thermostat goes in COMFORT mode it applies for both heating and cooling On receipt of a telegram O thermostat returns to the mode set by HVAC MODE object COMFORT mode can be set also with timing after a time set by a parameter thermostat returns in the previous mode KNX PARAMETER SETTINGS Comfort Object Time limited Time unlimited It is possible to enable the reading of a second external probe which sends the measurement data to the thermostat via the communication object ADDITIONAL TEMPERATURE of size 2 bytes KNX PARAMETER Ratio between internal and additional sensor SETTINGS 90 internal 10 external i 80 96 internal 20 96 external 70 internal 30 external 60 96 internal 40 96 external 50 96 internal 50 external i 40 internal 60 96 external 30 internal 70 96 external 20 96 internal 80 96 external 10 96 internal 90 external Additional sensor only This parameter set the weight to assign to internal and additional temperature Comfort Overwrite Time 1 255 minutes WINDOW CONTACT o
15. 57 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook Minimum time long press input Determines how long must be a press to be considered long if shorter than the selected value the press will be considered short 4 Channels Configuration Its possible to configure two inputs to work together by selecting the value combined in Channel Configuration page KNX PARAMETER SETTINGS Single Combined Single each channel can be configured independently Combined IN1 and IN2 combined to perform dimmer or shutter blind function KNX PARAMETER SETTINGS Temperature sensor Analog puts Thermostat d Temperature Sensor sends temperature on the bus Thermostat controls different types of actuators regulating heating and cooling measures an KNX 5 32 IO32DO1KNXFIO1040002 DOCX 5 Digital input x Configuration For each of the 2 input channels present on the device the selections are made through a configuration page Every single channel or input can be configured to perform one of the following functions Activation on press Activation on short and long press Dimming Shutter and blinds Scene Command in sequence on short and long press Command in sequence on edge KNX PARAMETER SETTINGS Activation on press Activation on short and long press Dimming Shutter and blinds Scene Command in sequence short long press Command in sequence on edge Activa
16. D01KNX Product Handbook It is also possible to set a delay on activation time This allows you to set the behaviour of the device when TON see ON with delay function it receives a OFF command Duration of relay activation TLS and ON delay time True TON are programmable by ETS On receiving a OFF command the device immediately executes the command and switch off the relay without waiting the end of the timing phase Telegram False On receiving a OFF command the device ignores the command and continues the timing phase the NO is load is deactivated at the end of the set time and it is closed not possible to deactivate it using a bus command f True open Warning Time seconds before time ends Switch Off Time ON delay time TON can be disable by ETS Here you can set the warning time before the deactivation of the stairway light function upon which the device will consequently signal the imminent termination of the stairway light function by switching off for a brief time the light Telegram Duration of relay timing can be stopped with an OFF NO is i command closed Telegram NO is open NO open Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K x Capitale sociale 800 000 00 interamente versato i Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 22 32 IO32
17. DO1KNXFIO1040002 DOCX Warning Function Telegram NO is Contact type closed NO NO is open Switch off time l Warning Time I KNX PARAMETER SETTINGS Send ON when Timing is active Ignore Trigger Mode Extension Mode This allows you to set the behaviour of the device when it receives a ON command while the staircase timing is running Ignore On receiving a ON command the device ignores it and goes on executing the timing Trigger Mode On receiving a ON command the device restart the stairs light time execuiting the whole time again Extension Mode On receiving the command the device extends the stairs light time increasing it by the time of the standard stairs light time Note that the extension option does not reset the timing but it changes its duration and becomes a multiple of the set stairs light time The maximum number of extension is allowed by the parameter Maximum numbert of Time Extension Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 IO32DO1KNX Product Handbook Duration of relay timing is re triggerable Telegram NO close NO open Extension Mode Telegram NO close NO open 14 5 ON FF vs Timing Functions ON OFF Commands have hi
18. I Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook 11 Behavior of Thermostat on voltage failure recovery and commissioning Behavior on bus voltage failure On failure of bus voltage no actions are executed by the device behavior of controlled actuators must be set using their own parameters Behavior on bus voltage recovery On bus voltage recovery all the communication objects are set to O except for objects for which a parameter is defined for the initial value Thermostat keeps these values in memory and restore them after recovery e Heat Cool mode if enabled e HVAC Mode if enabled e Base Setpoint if enabled e Force value in manual mode if enabled Control values i e commands to actuators are calculated on the base of actual setpoint and measured temperature A e After power on device recalculates the commands to actuators and switch them on if necessary otherwise does not carry out any action you are recommended to set the behavior of actuator in order to switch the heating cooling equipment off after bus power on Behaviour on commissioning ETS Download After download it is possible to set initial value of e Heat Cool mode if enabled e HVAC Mode if enabled For other communications obje
19. IO32DO1KNXFIO1040002 DOCX 1032D01KNX Product Handbook Qeseleciron INWALL 3 INPUT 2 OUTPUT MODULE 1032D01KNX Product Handbook Product IO32DO1KNX Description INWALL 3 INPUT 2 OUTPUT MODULE Document Version 1 4 Date 07 01 2014 Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K n x Capitale sociale 800 000 00 interamente versato IN Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1 32 IO32DO1KNXFIO1040002 DOCX IO32DO1KNX Product Handbook INDEX 1 E ariete eomm 4 2 Product and functional overview ii 4 3 General Parameter Configuration ii 5 4 aca arenis innata pie 5 5 Digital input lt x S C eere o p RTT ER 6 5 1 Activation on press edge iii 6 5 2 Activation short long press e T cms MEDIN ARRE RR IAA T o Input Shutter and Bid 7 5 5 Input Scene Management ei 8 5 6 Commands iN Sequence inner 8 6 Temperature Probes eee ne ee mE 9 T Temperature Sensor Function iii 9 8 MPG FIMO Stal FUNCION RR 10 9 Target Setpoint Settings ei 10 9 1 TWO points on off ii 12 s MR cu FYNN CONTO M omo omm 13 So lt Fontolonoli ili 13 9 4 Fan coil control or generic continuous control 15 10
20. S01B01ACC Epoxy resin closed in ABS plastic cap Twin wire AWG26 double PVC insulation ERO D1 9 mm D2 4 mm L2 49 mm L1 1250 mm NTC resistence tolerance t 296 Measure range 50 C 60 C Cable 2 wire double insulation Cable colour White NTC colour White Warning keep at least 3 mm from all live parts A Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook T Temperature Sensor Function The temperature probe allows a reading of the temperature within its range with resolution 0 1 C KNX PARAMETER SETTINGS 1 5 C 1 5 C with Temperature resolution 0 1 C calibration It s possible to add an offset to the temperature value measured by the probe before it is sent on the bus or made available for reading sensor Temperature cyclic Disable sending Enable It s possible to enable the periodic sending of measured temperature value if this option is disabled reading can be done only on read request If you enable the periodic sending the sending interval is set by this parameter SETTINGS Sending interval KNX PARAMETER Enable threshold T1 Disable low Enable You can also enable two thresholds for temperature and for each th
21. ance time expires without any message received thermostat start considering only the internal probe until it receives a new valid value from the additional probe in this case the additional value is taken in count again Anyway if the internal temperature is out of range or probe is disconnected short circuit then the control action is interrupted and the controlled actuators are switched off Obj 21 Actual temperature transmits O C regardless the value received from additional sensor Obj 39 Temperature sensor alarm transmits 1 When internal probe starts again to measure a in range value thermostat start again its control action P ames KNX 15 32 IO32DO1KNXFIO1040002 DOCX CONFIGURATION MODE 3 Internal probe Not connected Additional probe Connected or by bus Ratio between probes 100 external If the additional temperature is out of range or the surveillance time expires without any message received thermostat stops the control action and the controlled actuators are switched off If internal probe is anyway connected but not used until additional probe is working good then in event of failure of the additional probe the internal probe is used see behaviour of configuration mode 1 When additional probe begin to measure a in range value thermostat start again its control action and return to consider the additional probe Eelectron SpA Via Magenta 77 22 20017 Rho M
22. behavior of output is driven by Lock Object the parameter Behaviour on up PRIORITY Behaviour on commissioning ETS Download Relay Command Object Scene Object After download behavior of output is the same as Logic Object Behaviour on up Wrong application download Relay timing command If the wrong ETS application is downloaded then KNX EIB led starts blinking and device is not operative on the bus A power reset must be done and the correct ETS application must be downloaded Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K xX Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 26 32 IO32DO1KNXFIO1040002 DOCX 16 Electric valve control Each output can be configured to drive an electric valve solenoid valve typically used in heating and cooling systems for floor panels e e Use this output configuration when you want to drive an ON OFF type solenoid valve In this type of valve one of two states open or closed is associated with the condition of valve powered the other to valve not powered e e f you use this configuration the control algorithm must be resident in the control device thermostat etc the relay act only to power or not the valve 16 1 Main Parameters KNX PARAMETER 1 bit This parameter defines whether the relay co
23. bject Surveillance time for additional sensor 10 255 min Whenever the thermostat receive a valid data from This object if enabled has higher priority than HVAC 2 l l additional temperature sensor it consider this value in MODE SETPOINT MODE COMFORT objects When a telegram is received 0 or 1 on the communication object WINDOW CONTACT thermostat enters a power saving mode e BUILDING PROTECTION if running in HVAC MODE e Setpoint antifreeze high temperature protection if running in SETPOINT MODE Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 the calculation of the measured temperature and reset the internal time monitoring time if the surveillance time expires without receiving any valid data thermostat start considering only the internal probe at 100 until it receives a new valid data see paragraph 10 Temperature probe failure out of range measurement KNX 11 32 IO32DO1KNXFIO1040002 DOCX e f external probe is enabled the monitoring time is used to check if the additional temperature sensor periodically sends valid data to the thermostat This mechanism avoids to consider as valid some data which can be old hours or days for example ifthe additional sensor shou
24. cooling elements such as radiators heat pumps split etc 0 range from 50 C to 100 C with 0 1 resolution e Setpoint values sent to the device on the bus are accepted in a range from 10 C to 35 C from 10 C to 50 C from serial number 00048489 e Setpoint accepted in SETPOINT MODE are in a range from 0 C to 35 C from 10 C to 50 C from serial number 00048489 The thermostat operates temperature in a 9 Target Setpoint Settings The control setpoint can be changed by bus in two different ways via one of these objects e HVAC Mode e SETPOINT Mode The right policy to adopt depend from the device that acts as a master a time thermostat a control panel or a SW supervisor Here the list of object for changing the active mode or setpoint value by bus SETPOINT MODE object When Thermostat control mode parameter is selected with the value SETPOINT MODE object HVAC Mode is no longer visible Each time the thermostat receives a value on object SETPOINT MODE 2 byte size it is used as setpoint for temperature control Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 I032D01KNX Product Handbook HVAC MODE object switched heat cool Using the object HVAC MODE 1 byte size
25. creasing of performances no direct sunlight non esporre direttamente Ac Al CHG I Loe OVid c e e Do not install IRX too near to fluorescent lamps to avoid decreasing of performances Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook 12 1 Remote control configuration Buttons on RC01A01IRC remote control are indicated as follow ES ES wm eet post ine ones rige 5 M 2j 8 tO m me a 4 1 e 3 S P 6 i Si E Every channel on the remote control can be configured to perform one of the following functions e Activation on press e Scene e Command sequences channels form 1 to 4 12 2 Activation on press Configurations for 1 bit object in events pressing the remote control button e On Off e Toggle Configurations for 1 byte object in events of pressing the remote control button e Value 0 255 generic signed int e Value 0 100 scaling value in steps of 5960 e HVAC Mode value according to DPT HVACMode 20 102 o AUTO o COMFORT o STANDBY o ECONOMY o BUILDING PROTECTION KNX 18 32 IO32DO1KNXFIO1040002 DOCX 12 3 Scene In this configuration its possible to set the remote control channel for scene management only recall
26. cts the behavior is identical to bus voltage recovery Wrong application download If the wrong ETS application is downloaded then KNX EIB led starts blinking and device is not operative on the bus A power reset must be done and the correct ETS application must be downloaded 16 32 IO32DO1KNXFIO1040002 DOCX 12 Remote control Analog input alternatively to the temperature sensor can manage a Infrared Receiver IRX in order to forward to the bus up to 8 channel coming from a Infrared Remote Control IRC with on off commands scenes sequences of 2 objects dimmer and shutter This feature requires an accessory for infrared receiver e and a infrared remote control IRX cabling code IRO0A01ACC OnahWN This cabling provide a Infrared receiver digital input 1 and 2 with one common wire are always available Input 2 can be configured as a signalling led to show when a proper infrared command is received connecting eelectron LED code LDOOAOxACC or LDOOA1xACC IRC device code RC01A01IRC FS FAS goes 2 4 E O O 0 i CX i om 5 O 8 O PUR eo as e d a e 6 eie Re gt e e Infrared Remote Control needs a CR2025 battery included Infrared Remote Control provide 8 channels for the IRX in order to forward on KNX bus simple commands on off toggle scenes sequences of 2 objects 1 dimmer or 1 shutter Remote control has 8 channels that can be configured independen
27. dont ignore telegrams Valve Open Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook valve open position See notes Valve Close valve closed position See notes Keep previous state and ignore telegrams Relay returns in the state it was before lock function became active Keep previous state and don t ignore telegrams the output channel returns to its condition prior to the activation of the block unless you have received a telegram on the switch object or scenario in this case the last command received is executed e e f the parameter Initial Value for Lock Object has the same value of Telegram for Lock Activation happens that on power up the output channel starts in lock mode waiting for a unlock telegram in order to become active Note that even if the relay starts with lock function already active it does not go automatically in the position defined by the parameter Relay Position when Lock is Active because this behavior is determined only by the parameter Behaviour on power up e e The valve opened and valve closed conditions for each output channels correspond to ON or OFF condition of the relay upon the settings made for the
28. ds scenes sequences of 2 objects dimmer and shutter For NTC temperature probe the following eelectron code accessories must be used e S01A01ACC from 20 C to 100 C TS01B01ACC from 50 C to 60 C Outputs include switching function with timed delays staircase function scene recall lock or logic function Device 2 outputs on board can be configured e e Each output can be configured independently for load control 2 independent channels e Each output can be configured independently for ON OFF or continuous switching PWM for Electric valves solenoid actuators 2 independent channels e Outputs can be configured in pairs for the management of roller shutters and blinds 1 channel Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 IO32DO1KNX Product Handbook Digital inputs main functions e 1 bit commands load activation deactivation commands ON OFF TOGGLE with short press or with differentiation of long and short press e 1 byte commands unsigned 0 255 or HVAC commands or value commands e Sending of long action telegrams on the same address of short action or on a different group address e Cyclic sending e Sequences 3 commands mixing 1bit 1byte objects with diffe
29. ect switching value changes SETTINGS This parameter selects the value the lock object must have on power up Last value received is intended to be the last value received before power down Telegram Activation for Lock ho Last value received This parameter selects the values associated to the lock or unlock condition Relay Position when Lock Relay is Deactivated is Active Relay is Activated KNX 24 32 IO32DO1KNXFIO1040002 DOCX This parameter selects the state the relay must assume when the lock function becomes active See note Relay is Deactivated Relay is Activated se Keep previous state Position when Lock Ends and ignore telegrams Keep previous state and don t ignore telegrams Relay is Deactivated Relay is in OFF position See note Relay is Activated Relay is in ON position See note Keep previous state and ignore telegrams Relay returns in the state it was before lock function became active Keep previous state and don t ignore telegrams the output channel returns to its condition prior to the activation of the block unless you have received a telegram on the switch object or scenario in this case the last command received is executed e e If the parameter Initial Value for Lock Object has the same value of Telegram for Lock Activation happens that on power up the output channel starts in lock mode waiting for a unlock telegram in orde
30. ent of the louvers which is executed at the end of movements of the shutter these movements are e Movement for scene command if brings the shutter in a position different from totally up e Movement at the end of a lock or alarm state if brings the shutter in a position different from totally up e Movement for a Position command if brings the shutter in a position different from totally up This automatic function moves the louvers up after a shutter down movement and down after a shutter up movement KNX PARAMETER SETTINGS Never Louvers automatic Always movement After up movements After down movements Set when the automatic movement must start Number of automatic i 1 15 steps after move up Number of automatic 1 15 steps after move down This parameter set the time of the movement if this parameter is set to 2 and Step time for louvers movement x 100ms is set to 3 then the automatic movement is 300ms x 2 600ms In IO32DO1KNX 3 additional functions can be enabled for shutter e SCENE FUNCTION The scene function manage two possible commands to the device perform scene that is a command to create a specific condition learn scene that is a command to memorize the current status at the moment the command is received of the shutter position and then reproduce it once the perform command is received e LOCK FUNCTION this function according to the command received from
31. ess is executed The parameters and mode of transmission of telegrams can be managed through activation on long and short press are the same set with the configuration Activation of press edge to the exclusion of the function of cyclic sending that is not provided here Input Dimming Through the dimming function it s possible to control a light dimmer using short amp long press of a push button connected to the input channel Each channel uses 2 communication objects e 1 bit dimension for ON OFF command associated to short press operation e 4 bit dimension for brightness regulation associated to long press operation Input Shutter and Blind Through the Shutter and Blind function it s possible to control Roller Shutters or Blinds using short amp long press of a push button connected to the input channel Each input uses 2 communication objects e 1 bit dimension for STEP STOP command associated to short press operation e 1 bit dimension for UP DOWN command associated to long press operation KNX 7 32 IO32DO1KNXFIO1040002 DOCX Input Scene Management Function Scene Scene number 0 63 0 Store scene on long press Enabled Y Enable learn scene object Enabled E In this configuration page it s possible to set the input channel for scene management learn and recall scene commands 1032D01KNX Product Handbook Commands in sequence The function allows y
32. gher priorities respect timing command here some examples Timing is active and relay receives activation command ON e f received on CO Output x Relay timing command then it follows the parameter settings ignore trigger extension mode e f received on CO lt Output x Relay command then relay stay activated without timing Timing is active and relay receives deactivation command OFF e If received on CO lt Output x Relay timing command then it follows the parameter settings Timer can be stopped true false e If received on CO Output x Relay command then relay switch off and all the timings are reset P ams KNX 23 32 IO32DO1KNXFIO1040002 DOCX 15 Output Additional Functions 1032D01KNX Product Handbook e The result of the logical operation is applied to the communication object Output x Relay Command therefore the relay does not execute any timing function as a result of a logical operation In IO32DO1KNX 3 additional function can be enabled e LOCK FUNCTION this function according to the command received from the bus blocks the relay in a specific condition when a lock on command arrives this state is kept until a lock off command is received any command received during the KNX PARAMETER SETTINGS period in which the block is activated is not executed AND e LOGIC FUNCTION This function allows you to Logic function OR control the load not only usi
33. iguration for shutter e 29 17 1 Delay on opening and closing isesesecs laissini ceived bostwsndnndie svbtandaeusatdiased beta duaabdsuuedcocdasuansawsedblaidvsatehadivcusnnds 29 17 2 Louvers automatic movement on caincndiecinacdenccduentdestendnsecneanitecresses candies it 30 17 3 Additonal FUNCION ER PP a ii 30 17 4 Scene FUNCTION iii 30 17 5 LOCK FUNCION mE m T m ems 31 17 6 AERE T Em Tr 31 17 7 Shutter position after lock and alarm ei 31 17 8 Prionty E lo Sreg ou d e 31 17 9 Behavior of shutter on voltage failure recovery and commissioning 32 Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K x Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 2 32 IO32DO1KNXFIO1040002 DOCX Any information inside this manual can be changed without advice This handbook can be download freely from the website www eelectron com Exclusion of liability IO32DO1KNX Product Handbook Despite checking that the contents of this document match the hardware and software deviations cannot be completely excluded We therefore cannot accept any liability for this Any necessary corrections will be incorporated into newer versions of this manual Symbol for relevant informa
34. ion is ok to control lights or other loads accordingly to the maximum acceptable load for every type of lamp load see instruction sheet KNX PARAMETER SETTINGS NO Normally Open Contact Type NC Normally Close With this parameter you can set the operating mode of the relay The relay can be used as open contact or close contact This difference is logical because the relay has only one pole and it is not available a terminal connected to the NC contact Relay status Open Close closed open NO contact is NC contact is open closed KNX PARAMETER SETTINGS ON Behaviour on power down OFF STOP no movement When bus voltage fall down under approximately 18V device enters the power down routine and it is possible to set the status of the relay status ON OFF Keep status Power down On power up it is possible to set the status of each relay with this parameter Behaviour on power up before Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook When value Keep status on power down for the parameter Behaviour on power up is selected then it is maintained in memory the state of the relay before the power down sequence which can change the relay status accordinglt to
35. iquid driving a valve 2 pipe fan coil or two valves 4 pipe fan coil Liquid exchanges heat cool with the environment through a ventilation system controlled by a fan The fan is driven by an engine that typically has 3 windings that can be enabled at 3 distinct speeds Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K xX Capitale sociale 800 000 00 interamente versato i Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 13 32 IO32DO1KNXFIO1040002 DOCX Control logic for a 3 speed fan coil in heating When temperature increasing u VENTILATION OFF Tm D eegesed Bese NN PN TEMP SP Tdrvi ii i A 3 X V1ACTIVE REGULATION DIFFERENTIAL Tdrv1 TEMP SP Tsp i REGULATION DIFFERENTIAL Tdrv1 amp VIACTIVE i colui uc Ee TEMP SP Tdrvi gt lt L gt REGULATION DIFFERENTIAL Tdrv2 V2 ACTIVE TEMP SP Tdrv1 Tarv2 V3 ACTIVE When temperature decreasing u VENTILATION S OM nra TEMP SP Tdrv1 Lu VENTILATION S OFF x REGULATION DIFFERENTIAL Tdrv1 z t REGULATION DIFFERENTIAL Tdrv1 o VIACTIVE v i teme l TEMP SP Tdrvi gt i gt REGULATION DIFFERENTIAL Tdrv2 V2 ACTIVE A i MW TEMP SP Tdrvi Tdrv2 Y V3 ACTIVE Tr Where Tsp Target setpoint temperature Tari regulation differential in heating for V1
36. ld fail or the thermostat could not receive data for long time A e It is strongly recommended to set a value for surveillance time of the additional sensor more than twice of the period set for the cyclical sending of the additional sensor e e Ifthe external probeis weighted at 100 Parameter Ratio between internal and external external sensor only then when the monitoring time expires the thermostat switch off all controlled loads until the reception of a valid telegram ACTUAL SETPOINT object The ACTUAL SETPOINT object send the setpoint in use and is sent every time e The value of HVAC mode object changes e The value BASE SETPOINT changes e The value of SETPOINT ADJUSTMENT object changes e After download e One minute after power on 9 1 Two points on off Control algorithm 2 points on off is used to control heating or cooling elements that can be controlled by switching on and off of the same elements radiators underfloor heating with on off valves boilers etc When the thermostat switches to winter mode heat mode sends a off command on object ON OFF COOLING and operates the control only through the object ON OFF HEATING the object ON OFF COOLING is therefore not updated anymore until it returns in cooling mode Therefore in the transition from winter to summer mode sends a off command on ON OFF HEATING commands and activates the control through the object ON OFF COOLING
37. lue according to DPT_HVACMode 20 102 o AUTO o COMFORT o STANDBY o ECONOMY o BUILDING PROTECTION KNX PARAMETER SETTINGS on contact open close on contact open close cyclic if opened Telegram sending on contact open close cyclic if closed on contact open close and always cyclic 6 32 IO32DO1KNXFIO1040002 DOCX Note 1 When periodical sending is enabled for one only of the two edges switching in the state where no telegram is associated causes the periodic sending stop Note 2 If yu want to handle both instant sending and periodic sending on only one oftwo fronts without performing an action on the other forthis you must select the option no telegram Note 3 If you connect an input to a wind rain or frost sensor with dry contact output you should probably set the parameter mode sending telegrams as Immediate amp cyclic on open close in order to have the periodic sending of telegrams Check telegrams value and time expected from the actuator controlled Enabled Disable by the sensor Feedback object Can be used when push button is set as 1 bit Toggle in order to have always the status of actuator updated Send Telegram on Enabled power up Disable With this parameter it is enabled the sending of the status of the switch without having to wait for a change of front a telegram is sent accordingly to the open close state of the contact No
38. lure recovery and commissioning Behavior on bus voltage failure recovery and on commissioning ETS Download Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 I032D01KNX Product Handbook On failure or recovery of bus voltage output are always opened Wrong application download If the wrong ETS application is downloaded then KNX EIB led starts blinking and device is not operative on the bus A power reset must be done and the correct ETS application must be downloaded 32 32
39. n the reception of a telegram of activation and the switch of the relay the OFF switch is automatic after a configurable time staircase timer 14 3 Function ON OFF with delay In this configuration it is possible to set a time delay on the relay activation TON and also a delay time for the relay deactivation TOFF The opening and closing of the contact when the parameters are different from zero occurs later than the receipt of the telegram Activation and deactivation delays are set separately KNX PARAMETER SETTINGS Delay on Activation s False Delay on Deactivation pne False Delay on Activation Base ern 1 minute Time 1 hour Delay on Activation 1 255 Factor The delay time between the receipt of a telegram and the execution of the command is given by Delay of Activation Time Delay on Activation Base Time x Delay on Activation Factor 1 sec 1 minute 1 hour Delay on Deactivation Base Time Delay on Deactivation Factor 1293 The delay time between the receipt of a telegram and the execution of the command is given by Delay of Activation Time Delay on Deactivation Base Time x Delay on Deactivation Factor KNX 21 32 IO32DO1KNXFIO1040002 DOCX 14 4 Function ON with delay timing OFF After receiving a telegram from the Relay Command Object the relay is active for a time TLS that can be set by a parameter when TLS expires it turns off automatically False 1032
40. nce a cycle time is defined the thermostat sets the or UNITE gt actuator to ON for a fraction of the cycle time and OFF O for the remaining part Driving the actuator with the as i AI gt control value of 80 means that it is active i e ON for SER tan cone i TONED 80 of cycle time and OFF for the remaining 20 sr ae a at Ses os e gin e 100 ON PWM control in cooling mode 100 ON eee 8 TARGET SETPOINT Bp KNX PARAMETER SETTINGS Cycle time TCp 10 20 30 60 min 2 22 2 22 r It defines the time interval n gt Zo 60 ON 40 OFF Wi f Ca M e 2 Proportional band Bp 0 8 1 2 1 6 2 0 C d lt O 40 96 ON 60 OFF The proportional band BP is a range of temperatures Q between Setpoint and Setpoint Bp in heating mode E E TARGET and between Setpoint and Setpoint Bp in cooling SETPOINT mode within this interval thermostat controls the temperature using the proportional algorithm outside It 100 OFF drives actuator always in ON or OFF When temperature is inside this range device wait the end of the cycle time before calculating the duty cycle of the next cycle When temperature is outside of this range below Setpoint Bp in heating mode or above Setpoint Bp i in cooling mode it starts a new cycle as soon as 9 3 Fan coil on off temperature enters the B i i Fan coil is a device that controls the flow of cooling heating l
41. nd parameters are the same used in On off with PWM control mode the difference is that now the proportional value is sent to the bus via a 1 byte object format as a 9o value from 0 to 100 This mode is useful to control fan coils selecting 2 or 4 pipes or generic proportional actuators as valve drivers only linking the 1 byte communication object and avoiding to link the valve objects CONTINUOUS CONTROL object This 1 Byte object send control value to actuator SET MAN AUTO MODE object SET MAN AUTO MODE Objects is a CO for changing the calculation mode for CONTINUOUS CONTROL object in AUTO Mode the calculation is carried out via a proportional algorithm A temperature between actual temp and Setpoint Temp and a integral correction Cycle Time in MAN mode the output value control is set by the value send to the object FORCE VALUE IN MANUAL MODE object 10 Temperature probe failure out of range measurement A e f the temperature probe is disconnected or in short circuit the control action is interrupted and the controlled actuators are switched off A e The value of temperature sent on the bus in case of probe disconnection or short circuit or for out of range measured value is 0 C according to KNX DPT_Value_Temp 9 001 TEMPERATURE SENSOR ALARM object In event of temperature probe failure out of range measurement a telegram from 1 bit communication object obj 39 Temperature sensor alarm is sent
42. ng the relay Switch XOR This parameter selects the logical operation Command object but using the result of a logic operation the logic function consists in two logic ports the operation is performed among the logic Initial Value for logic input and the relay command object Operation 1 l e SCENE FUNCTION The scene function manage Last value received two possible commands to the device perform scene that is a command to create a specific condition learn scene that is a command to memorize the current status of the contact at the moment the command is received and then reproduce it once the perform command is received This parameter selects the value the logical object must have on power up Last value received setting is intended to be the last value received before power down e e The value assumed by the logic communication object set by the parameter Initial Value for logic Operation does not switch automatically the relay because this behaviuor is determined by the parameter Behaviour On power up LOCK and LOGIC function are alternative functions and only one of them can be enabled at a time 15 1 Logic Function Enabling logical operation allow to submit the command for the output to a result of a logical operation between the communication object lt Output x gt Logic Function and the communication object lt Output x gt Relay 15 2 Lock Function Command or lt Output x gt Rela
43. ntrols of the valve is carried out with 1 bit ON OFF or 1 byte 0 to 10096 commands When you select the 1 byte value the control is done through a PWM See notes is open Valve Close This parameter permits to set the behavior of the relay according to the state of the valve If you have a valve that opens when the relay is closed and you want it to be activated by an ON command of a thermostat most common situation you must set this parameter at the value Valve Closed and the parameter see below Activation telegram with value Telegram O close the valve SETTINGS Telegram 0 close the valve Telegram 1 close the valve It is possible to set a parameter to determine if the function is activated with a telegram O and then off with 1 or is activated with telegram 1 and then off with 0 f 5 min to 60 min in step Cycle Base Time For PWM See notes Lower limit value Activation telegram Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 IO32DO1KNX Product Handbook Defines the minimum value below which the valve is always closed 0 1096 20 30 Upper limit value Defines the maximum value above which the valve is always open 70 80 90 100
44. o determine a correct value of the parameter debounce time to avoid these bounces could be taken by the device as input switching How this parameter works after the device has detected a change of status for an input channel it waits for a time equal to the time set as debounce time before updating the value of the corresponding data point The input signal is not evaluated during this time This parameters affects all 8 device input channels where present Input Signal Edge detected Delay on Power up 5 15 seconds Through this parameter is possible to set the delay of transmission of telegrams after a power on by selecting the time by which the device is allowed to send telegrams In large systems after a power failure or shutdown this delay avoids to generate excessive traffic on the bus causing slow performance or a transmission block If there are different devices requiring sending telegrams on the bus after a reset these delays must be programmed to prevent traffic congestion during the initialization phase The input detection and the values of objects are updated at the end of the transmission delay time At the end of ETS programming the device behaves like after a power on Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 3591
45. ou to associate to short and long press sequences of different commands on the bus For inputs this function is available for short and long press or for edges evaluation The sequence consists of 2 or 3 commands which can each be sized as 1 bit or 1 byte Once defined the number of elements in the sequence 2 or 3 and their size 1 bit 1 byte you can associate different commands to each element of the sequence or decide to send commands only on one of the two events The waiting time between a command and the next is fixed in 1 second Each object communication can be connected to a These different behaviour recall and learn are performed through two different actions short and long press of a push button connected to the input channel different group address For example it is possible to define a sequence C Command on Command on om ui short press long press edge edge 1 bit ON OFF to actuators to actuators Learn scene on long press action is enabled by a parameter KNX PARAMETER SETTINGS Number of the scene 0 63 This parameter sets the value of the scene you intend to learn recall one per channel Scene Number eva 100 0 y to a dimmer to a dimmer C bore COMFORT ECONOMY y to a thermostat to a thermostat Remember that output devices i e actuators etc generally can manage several scenes each identified by a value that varies from 0 to 63 therefore is important to se
46. ower down Valve Close STOP no movement 27 32 IO32DO1KNXFIO1040002 DOCX When bus voltage fall down under approximately 18V device enters the power down routine and it is possible to set the status of the relay status See notes Valve Open Behaviour on power up Valve Close STOP no movement On power up it is possible to set the status of each valve and therefore the relay with this parameter See notes e e PWM control is used to reduce the hysteresis of the temperature typical of ON OFF control The relay drives the valve with ON OFF commands and make a proportional control 0 100 based on the value received on the CONTINUOUS CONTROL OBJECT modulating the amplitudes of the On and OFF pulses PWM This mode is active when 1 byte control was previously selected e e When is selected the value STOP no movement for the parameter Behaviour on power up it is maintained the state assumed before power down 16 2 Lock Function KNX PARAMETER SETTINGS Telegram 0 for Lock Telegram 1 Telegram Activation This parameter selects the values associated to the lock or unlock condition Valve Open Valve Position when Lock Valve Close is Active This parameter selects the state the valve must assume when the lock function becomes active See notes Valve Open Valve Close Keep previous state Position when Lock Ends and ignore telegrams Keep previous state and
47. r selects the values associated to the alarm condition Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook e f Alarm Function is enabled it is mandatory to link a sensor with cyclic telegram sending if the communication object is not linked or no telegram is received before the end of supervision time the alarm becomes active and the shutter goes in alarm position 17 7 Shutter position after lock and alarm This parameter set the final position of the shutter after the end of a lock or an alarm condition of course if both functions are no active the value of this parameter is not considered KNX PARAMETER SETTINGS Move Up Shutter position after lock and alarm move Down Previous position and ignore telegrams This parameter selects the values associated to the end of lock or alarm condition 17 8 Priority Table for shutter Power down behavior relay are always opened Power on behavior relay are always opened only for shutter mode Lock Object PRIORITY Alarm Object Up down movement Stop movement Object Scene Object Absolute position Object Step movement Object KNX 31 32 IO32DO1KNXFIO1040002 DOCX 17 9 Behavior of shutter on voltage fai
48. r to become active Note that even if the relay starts with lock function already active it does not go automatically in the position defined by the parameter Relay Position when Lock is Active because this behaviuor is determined only by the parameter Behaviour on power up e e The activated and deactivated conditions for each output channels correspond to ON or OFF condition upon the settings made for the Contact Type parameter Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 IO32DO1KNX Product Handbook 15 3 Scene Function When the scene function is enabled a communication object named lt Output x Scene becomes visible It is possible to send to the device two possible commands e recall scene is a command to create a specific condition e Store scene is a command to learn and store the current status at the moment the command is received of the contact and then reproduce it once the recall command is received For every channel it is possible to store a maximum of 4 output scene KNX PARAMETER SETTINGS For the 4 possible scenes this number is the unique identifier for the scene valid numbers are from O to 63 64 means scene is not active Initial value Scene x
49. rent group addresses e Edges for 1 bit 1 Byte sequences e Dimmer management with single or double push button e Blind Roller Shutter management with single or double push button e Scene management e Input 2 can be used to drive a LED for signaling when Infrared receiver is configured IRX e For digital inputs IN1 IN2 Max length of e Connecting Cable 30 m twisted cable e For analog input IN 3 Max length of Connecting Cable S 20 m twisted cable Analog input main functions Configured as Temperature sensor main functions e 2 different temperature thresholds to trigger 1 bit telegrams alarm warning e Enable disable of alarm warnings via 1 bit object Configured as Thermostat main functions e Different control algorithms 2 point on off PWM Continuous Control Fan Coil Control e Different setting modes via HVAC automatic via HVAC Manual via Setpoint e Window contact function e Additional external temperature sensors optional QUT m KNX 4 32 IO32DO1KNXFIO1040002 DOCX 3 General Parameter Configuration KNX PARAMETER SETTINGS 80 ms 100 ms 40 ms Input debounce time 150 ms 200 ms 600 ms 1 sec When a button connected to the input is pressed it is possible to have the contact opened or closed more than once before fixing into a stable position this can be caused by a rapid succession of bounces between mechanicals contacts For this reason it is important t
50. resholds send a telegram of attention of size 1 bit whenever the measured temperature exceeds or falls below the threshold For each threshold can be set whether to send the telegram 1 when the measured temperature T exceeds the threshold temperature Tx and then send the telegram 0 when the measured temperature T becomes less than the threshold temperature Tx or vice versa Enable threshold T2 Disable high Enable See description of Enable threshold T1 low Value threshold T1 15 C 55 C Value threshold T2 15 C 55 C Telegram to send when Telegram 0 T T1 bas Telegram 1 Telegram to send when Telegram 0 T T2 Telegram 1 Object enable for Hide Show Trigger 1 and 2 KNX 9 32 IO32DO1KNXFIO1040002 DOCX It s possible to enable disable the remote temperature sensor with a communication object When this object is enabled and receives a telegram 1 the temperature probe is active and sends trigger telegrams according to thresholds T1 and T2 values otherwise only temperature value is periodically sent Initial object 7 T EN to initialize enable object as active inactive 0 after power on reset or download Allows 8 Thermostat Function The temperature sensor can be configured as a thermostat to control the temperature of a room or area by driving heating or cooling equipment air conditioning fan coils valves or through commands on off to heating
51. t this parameter correctly and matching the number set on the actuators Store scene on press long Disable If disable long press action is ignored and no telegram is sent to the bus if enable on long press action a learn scene telegram is sent to the bus Enable learn Scene Disable object Enable If this parameter is enabled you have a communication object size 1 bit When this object receives a telegram 1 then the function associated to the long press of the button send the telegram storage scenario is enabled when it receives a telegram O the command associated with the long press is not sent Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K x Capitale sociale 800 000 00 interamente versato i Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 8 32 IO32DO1KNXFIO1040002 DOCX 6 Temperature Probes NTC temperature probe eelectron code TS01A01ACC or TS01B01ACC e S01A01ACC from 20 C to 100 C e e S01BO1ACC from 50 C to 60 C e Max length of Connecting Cable lt 20 m twisted cable TS01A01ACC Twin wire AWG26 Epoxy resin PVC insulation P Dimensions in millimetres NTC resistence tolerance 3 Measure range 20 C 100 C Cable 2 wire single insulation Cable colour Black NTC colour Black Warning keep at least 6 mm from all live parts A T
52. te 1 If you enable the sending of the telegram for an input where you have already set the cyclic sending then the cyclic sending will start automatically at power on at the end of the first period Note 2 If the command selected is TOGGLE the first value sent is always 1 because the CO value on power on is 0 5 2 Activation short long press The difference duration between short and long press is defined by the generic parameter Minimum time for long press input lt x gt You can set to send a telegrams with different values on short and long press or decide to send commands only on one of this events Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook SHORT PRESS LOMG PRESS OFLM CONTACT OLOSF CONTACT Te MinMiMUM TIML FOR LUNG PRESS When contact is closed and the debounce time is over then counting time to contact closure starts if the contact is opened again note that debounce time is considered also in contact opening before time exceeds TPL time device executes the command associated with the event of short press and if on the contrary TPL timeout expires and contact is still closed then the command associated with the event of long pr
53. the parameter Behaviour on power down SETTINGS KNX PARAMETER Activation telegram Telegram 0 Telegram 1 For every function above selected you can set a parameter to determine if the function is activated with a telegram O and then off with 1 or is activated with telegram 1 and then off with 0 ON OFF with delay ON with delay timing OFF Timing Function ON OFF with delay it is possible to set a delay between the reception of a telegram and the switch of the relay for both telegrams activation and deactivation ON with delay timing OFF it is possible to set a delay between the reception of a telegram of activation and the switch of the relay the OFF switch is automatic after a configurable time staircase timer Disabled When status changes On request Relay Feedback Disabled Status is never transmitted ad related communication object is not visible When status changes Status is transmitted every time the relay switch changing his status from ON to OFF or from OFF to ON On request Status communication object is available and updated when status changes but the telegram is not transmitted Read propriety is enabled Telegram 0O when Telegram value for status value is OFF sending Telegram 0 when value is ON This parameter defines which telegram value is associated to the ON or OFF status P ames KNX 20 32 IO32DO1KNXFIO1040002 DOCX
54. tion e Symbol for warning fh Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 EB n KNX 3 32 IO32DO1KNXFIO1040002 DOCX 1 General Introduction This manual is intended to be used by installers and describes functions and parameters of the device IO32DO1KNX and how is possible to change settings and configurations using ETS software tool 2 Product and functional overview IO32DO1KNX module is designed to be installed in Home and Building installations i e offices hotels private houses etc The module includes two digital inputs to interface free potential contacts one analog input for temperature sensors and two relay output bistable Digital inputs are intended to be connected to sensors traditional buttons etc they can be used to on off commands dimming shutter control scene recall and control sequences of 3 objects Analog input can manage one temperature probe with On Off threshold or one thermostats to control heating and cooling equipments valves 2 and 4 pipes fan coils etc Analog input alternatively to the temperature sensor can manage a Infrared Receiver IRX in order to forward to the bus up to 8 channel coming from a Infrared Remote Control IRC with on off comman
55. tion on press see par 5 1 Activation on press edge Activation on short and long press see par 5 2 Activation short long press Dimming see par 5 3 Dimming Shutter and Blind see par 5 4 Shutter and Blind Scene see par 5 5 Scene Management Command in sequence see par 5 6 Command in sequence 5 1 Activation on press edge The Activation on edge allows you to configure the sending of telegrams when the state ofthe contact switch from open to close and vice versa You can set to send a telegram with different values associated with different edges ordecide to send commands only one of the two edges With the Activation of the press edge selection device can also be configured to send periodic messages with repetition period Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook KNX PARAMETER SETTINGS Telegram Associated i dis It is possible to send 1 bit or 1 byte objects Configurations for 1 bit object in events of closing or opening contact Nothing no telegram On Off Toggle Configurations for 1 bit object in events of closing or opening contact e Value 0 255 generic signed int e Value 0 100 scaling value in steps of 5 0 HVAC Mode va
56. tly then channels 5 6 7 8 can be set together to integrate a special function A e When 1032D01KNX device is enabled to manage infrared receiver and infrared remote control the temperature sensor cannot be connected anymore and is not possible to enable the thermostat function Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 1032D01KNX Product Handbook There are no special procedures to link together IO32D01KNX device and a RC01A01IRC remote control only in ETS it is necessary to enable the peripheral Infrared receiver This means that every remote control can be received by any IO32DO1KNX this must be taken in count to avoid unexpected behaviours Consider that the communication between infrared receiver and remote control is optical infrared therefore the remote control must see the infrared receiver The maximum distance between remote control and infrared receiver is 8 mt And the maximum angle is 90 45 left or right To have a reliable communication between infrared receiver and remote control it is necessary to direct the remote control at the point where the infrared receiver is installed 17 32 IO32DO1KNXFIO1040002 DOCX e e Do not install IRX on direct sunlight to avoid de
57. ton 8 Light OFF Button 6 Light Brightness Increment Button 7 Light Brightness Decrement SHUTTER Button 5 Shutter UP Button 8 Shutter DOWN Button 6 Shutter Stop Shutter Step UP Button 7 Shutter Stop Shutter Step DOWN HVAC MODE Button 5 BUILDING PROTECTION Mode Button 8 STANDBY Mode Button 6 COMFORT Mode Button 7 ECONOMY Mode MANUAL FAN COIL long press 100 1 byte COMFORT ECONOMY to a thermostat to a thermostat This mode acts on 2 different communication object 1 is a 1 byte obj to set the value of the fan coil speed 2 is a 1 bit obj to set to MAN 0 the manual auto mode of fan coil controllers Every 1 byte value of the buttons can be selected from 096 to 100 in steps of 5 Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 K xX Capitale sociale 800 000 00 interamente versato i Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 19 32 IO32DO1KNXFIO1040002 DOCX 13 Output Configuration Device 2 outputs on board can be configured e Each output can be configured independently for load control 2 channels e Each output can be configured independently for ON OFF or PWM switching for Electric valves solenoid actuators 2 channels e Outputs can be configured in pairs for the management of shutters 1 channel 14 Generic load control This configurat
58. tput scene KNX PARAMETER SETTINGS For the 4 possible scenes this number is the unique identifier for the scene valid numbers are from O to 63 64 means scene is not active Values between 0 and 100 in steps of 596 For the 4 possible scene this number allow to initialize the position associated to previously selected scene number avoiding to execute the store scene procedure If the store scene is done this value is overwritten Enabled Disabled Initial value Scene X Learn Scene This parameter enable disable the output channel from storing value received from the bus if this parameter is set to disable the value associated are set only by the parameters Initial value Scene lt X gt and cannot be modified without a ETS download e e After a ETS download the device assumes the value of parameter Initial value Scene lt X gt as a value in memory for the corresponding scene and overwrites previous memorized scene positions KNX 30 32 IO32DO1KNXFIO1040002 DOCX 17 5 Lock Function When lock function is enabled it allows as a result of receiving a telegram on the Channel x Lock Function to set the shutter in a defined position and force it to maintain this position even if the channel receives move commands e e f the parameter Initial Value for Lock Object has the same value of Telegram for Lock Activation happens that on power up the shutter channel starts in lock
59. wnload these setpoint are reset to values according to ETS parameter on power up these object are set according to last values before power down e Use these communication objects to e change current setpoint for every HVAC Mode according to the current active control heating or cooling KNX 10 32 IO32DO1KNXFIO1040002 DOCX 1032D01KNX Product Handbook If the telegram received indicates that the window is opened thermostat change its mode or setpoint after 1 minute from the reception of the telegram When it receive a telegram corresponding to state window closed it restores the previous mode always with a delay of 1 minute The value of SETPOINT ADJUSTMENT if enabled is always restored SETPOINT ADJUSTMENT object The object SETPOINT ADJUSTMENT allows you to temporarily change the setpoint value used by the thermostat applying an offset to the current value If the thermostat is operating in HVAC MODE the offset value is applied from the time of receipt of a valid telegram on object SETPOINT ADJUSTMENT until this value does not change even in case of change of the active mode Comfort and Standby only this does not happen with regard to Economy mode and Building Protection in this modes the value of object SETPOINT ADJUSTMENT is forced to O Similarly if the thermostat is operating in SETPOINT MODE the offset value is applied also when the setpoint value received on this object changes COMFORT OBJ 3
60. y Timing Command 1 Update on lt Output x gt Relay Command result of the logic operation between this object and the lt Output x gt Logic Function object is applied to the object lt Output x gt Relay Command no timing function 2 Update on Output x Relay Timing Command result of the logic operation between this object and the Output x Logic Function object is applied to the object Output x Relay Timing Command timing function performed 3 Update on Output x Logic Function result of the logic operation between this object and the Output x gt Relay Command object is applied to the object Output x Relay Command no timing function By ETS is possible to select the logical operation to use every time a telegram is received on the logical object or on the control object then the logical operation is calculated again and the result is taken as a command for the relay Eelectron SpA Via Magenta 77 22 20017 Rho MI Italia 39 02 9316681 39 02 93507688 info eelectron com www eelectron com C F e P IVA 11666760159 Capitale sociale 800 000 00 interamente versato Tribunale di Milano 359157 8760 07 CCIAA Milano 148549 KNX PARAMETER Initial Value for Lock B Object Last value received When lock function is enabled it allows as a result of receiving a telegram on the Output x Lock Function to switch the relay in a defined state and force it to maintain this state even if the obj