Contents
1. Connection and troubleshooting The computer is fitted with 6 cramps which may be connected to GND ground or 12V Key to the picture below Manuelt indput 12V Gnd Input manual mode 12V Gnd Auto indput 12V Gnd Input auto mode 12V Gnd Fodpedal indput 12V Gnd Foot pedal input 12V Gnd Foderpumpe frem output Gnd 12V Forward feed pump output Gnd 12V Foderpumpe frem output Gnd 12V Feed pump direction reverse output Gnd 12V Ledningsnet indput sk rmbillede Gnd 12V Wiring harness input screen display Gnd 12V Programmeringsstik programming plug in Manuelt indput 12v Gnd Auto indput 12v Gnd Fodpedal indput 12v Gnd Ledningsnet indput sk rmbillede Gnd 12v Foderpumpe frem output Gnd 12v Programmerings stik Foderpumpe revers output Gnd 12v The connection of Farm Assist s computer to the feed trolley is fitted with two plug ins one with 9 poles and another with 12 poles having the following connections with the trolley Pin number Function Pin number Function 1 Ignition 12V 1 2 2 3 3 4 Foot pedal input 4 5 Feed encoder input A 5 6 GND 6 7 7 8 Feed pump forward output 8 9 Feed pump direction reverse 9 Manual input from the 0 3 output switch 10 Direction reverse Auto input from the 0 3 switch 11 Feed encoder input B 12 It is possible to provi
2. feed to the system using the arrows or gt volume displayed in grams Press the O key and the calibration coefficient will appear Press the O key again to return to the menu Note In case after performing the calibration you go directly to its verification Farm Assist will have to adjust during the first 5 10 portions Consequently the initial test will be imprecise so you may put the first 5 10 portions back to the container The same will occur if you go to the portioning program in this case the first 5 10 portions will be larger until the system adjusts The system will behave this way upon each engine turn off e Calibration coefficient gt Here you may check the calibration coefficient You may also change the coefficient manually However we do not recommend doing so as the best way is to perform another calibration if the test results are unsatisfactory Portioning Here 3 lines are displayed Press and 7 to navigate through the lines e Program number change the number using and gt there are 99 programs e Weight adjust it using lt and gt e Time between portions adjust it using lt and gt You do not have to save the changes Farm Assist will do it automatically In the bottom empty line there may appear information on e g maintenance time or that oil pressure reduction is recommended in order to ensure more precise feed giving of small portions This information appears if the syste
3. Jasopels Farm Assist V3 Portioning System CALIBRATION FEED DISPENSING SETUP User manual This user manual contains specification of different functions of the Farm Assist system Upon starting Farm Assist you will see a screen see below with information about the system Farm assist version Udviklings ar serie nr for den aktuelle farm assist Software versions nr Hardware versions nr Key Farm assist version Software versions no Serie nr for den aktuelle farm assist serial no of the particular Farm Assist system Udviklingsar year of construction Hardware versions no If the 0 1 2 3 switch is set to position 1 manual feeding the following screen will appear displaying the amount of feed for a given day in kilograms This count as well as the operation count must be cleared by the operator HANDEL FODRING am af ema eee Entry in the picture above Manual feeding 86 kg translator s note If the 0 1 2 3 switch is set to position O or 2 direction reverse the following information will appear e Feed amount for a given day in kg it may be cleared like the operation counter e Total feed amount in tonnes no clearance option e Time remaining to maintenance e Farm Assist s activation period it is cleared upon each Farm Assist start Key to the left side picture r i H rI P i re Dag foder 86 kg feed amount for a given day 86 kg j d r T i ea pt T
4. de an adapter from the old 15 pole white molex plug in old Soffie machines to the new green plug ins provided with the Farm Assist system
5. g you may create a program with a large portion e g 1000 g and release the button when the portion reaches an appropriate size After the changed time before direction reverse the feed pump will reverse the pumping direction This requires adjusting the time before direction reverse and adapting it to the individual user s work mode e Time before direction reverse gt This function allows you to determine the time after which the feed pump reverses the direction after the foot pedal is released The adjustment is made in milliseconds If the parameter is set to 0 the feed pump will reverse the direction right after releasing the pedal It may occur that the pump does not reverse the direction if a portion is damaged or a cage is omitted e Language gt Here you may choose between Danish English or Polish e Maintenance count clearance gt Here you may clear the maintenance count when maintenance has been performed Normally the time is set for 50 hours for the first maintenance The maintenance interval may be changed only using the menu reserved for technical staff secured by a password Please contact Jasopels service department Status e Farm Assist s hours of operation no clearance option e Total feed amount no clearance option e Feed status gt Here the numbers data concerning the last portion given are displayed This function may be useful for Jasopels service department when fixing the machine or adjusting its settings
6. m calculates that the desired portion corresponds to approx 40 pulses which is a maximum capacity of the feeding machine at a full flow in the hydraulic system NOTE The Farm Assist system is an intelligent feeding computer that adjusts automatically all the time and thus adapts to the conditions Below you will find the parameters which the computer takes into account during feeding e Hot and cold oil e Idle and full capacity operation e Full and reduced flow in the hydraulic system Settings e Clearing the daily feed count gt This function allows you to clear the daily feed counter just like the operation count The count appears both when the 0 1 2 3 switch is set to position 1 manual and 2 direction reverse e Increasing the portion in grams gt This function allows you to determine by how many grams the first portion should be increased after the direction of the feeding pump is reversed The adjustment is made in order to compensate after the machine operates with reversed pumping direction The function will be deactivated if the position is set to 0 The function is active only if the pumping direction is reversed e Pumping direction reverse in grams gt This function allows you to determine by how many grams the feed pump will reverse the pumping direction after the footswitch is released The function will be deactivated if the position is set to 0 Hint if you like this function and want to use it while manual feedin
7. otal foder 0 T total feed amount Ot TOTAL FODER GTO ZM SERVICE BE TINE 0042 If the 0 1 2 3 switch is set to position 3 auto Farm Assist will start from the portioning menu Navigate through the menu using the arrows T and J to select a line use the arrow gt to go forward in the selected line Press the O key to return from a sub menu Use the arrows amp and gt to change a digit or the yes no option The menu contains the following items e Menu reserved for technical staff access password required please contact Jasopels service department e Calibration e Portioning e Settings e Status Below you will find descriptions of different functions Each function is described separately Calibration e Check the calibration gt Here you may check if the calibration has been made correctly Farm Assist counts 20 portions of a selected feed in grams on its own taking into account the frequency of portion giving pause time The portions should be weighed out to a bucket and verified e Perform the calibration gt gt gt gt gt Start the mixer Start the engine Hold the hose above the feed container and press the pedal the system will give 20 portions in order to deaerate and give uniform consistency to the feed Place an empty bucket on the scale and reset the scale Hold the hose above the bucket and press the pedal the system will give 20 portions Introduce the weighted amount of
Download Pdf Manuals
Related Search
Related Contents
MANUALE DI ISTRUZIONI USER MANUAL My First Disney Princess Touchpad the manual Bedienungsanleitung Bushnell WEATHERFX 960900C User's Manual Czech Technical University in Prague Faculty of Electrical Engineering Xante FilmMaker 4 Printer J24007.010D-R02_de_Miwell-Combi SL_Zug - V-Zug VPL-CX70 ON-EAR WIRELESS OWNER`S MANUAL Copyright © All rights reserved.