Home
White Paper: Precision Optical Bandpass Filters
Contents
1. Focal plane Due to the complexity and custom nature of pupil plane installations focal plane setups are far more common and popular Here the filter is placed in a sufficiently slow focal beam near the point of focus such that the converging light cone fits through the 32 or 45mm clear aperture of the Quantum In this way no additional focusing optics are required beyond the telescope objective In focal plane telescope applications focal ratio is an important consideration if the desired sub angstrom bandpass is to be accomplished Angular light of fast focal ratios causes a cumulative widening of FWHM due to tilt effect blue wing shift of light transmitted Focal ratios of F 28 F 35 are ideal for filters of 1 0 or less Focal ratios of F 15 F 20 are appropriate for filters of 2 0 5 0 The following chart models the impact of a faster than recommended focal ratio on a 0 5 Quantum filter As the focal ratio shortens towards the left of the chart the FWHM quickly exceeds a usable value In addition to the overall widening a pronounced hot spot effect occurs at low focal ratios as the center of the field of view experiences less angle of incidence as compared to the outer areas 17 2 25 2 00 1 75 1 50 1 25 Filter FWHM Angstroms 1 00 0 75 o 0 5A Nomina 0 50 10 15 20 25 30 Telescope Focal Ratio F number Figure 12 FWHM widening with suboptimal focal ratios Focal ratio may be manipul
2. Figure 5 Calcium H spectrum H line is often used because it too offers additional information for study of the solar atmosphere Numerous groups perform specific investigations of the 3969 line most often in conjunction with K line for studying grain formations due to shock Studies in Ca Il K and H line reveal complex temporal variations in the chromosphere Helium Studies of the Helium lines are typically involved in research of solar flares Contours of emission and absorption lines in flares are studied in Helium D3 at 5875 6 A Also two of the most attractive spectral windows for spectropolarimetric investigations of 9 the physical properties of the plasma structures in the solar chromosphere and corona are the ones provided by the spectral lines of the He 10830 A and D multiplets whose polarization signals are sensitive to the Hanle and Zeeman effects The 10830 line offers significant information but is only applicable from high altitude and space borne viewing platforms due to the interference of terrestrial Oxygen lines The line is also in the infrared where the quantum efficiency of most Silicon based CCD cameras is very low due to the proximity of the Silicon bandgap Special IR wavelength imaging sensors are required for such an application Alternatively the He D3 line offers value in terrestrial applications Isolation and identification of the line is a challenge due to the narrow width of its absorption line
3. 41 40 PL _A gt Am m E 39 98 Figure 28 Side view of serial cable port 43 44 92 84 Customer mounting holes 3x female 6 32 UNC threaded inserts each side on 63 5mm circle spaced 120 Recommended screw penetration 6 9mm 77 46 80 84 Figure 29 Adapter plate hole pattern and overall dimensions Y UA N 27 18 31 75 Mii mmm Y fi DS gt W V 7ZZ E Ny ZZZZA ee iy Th E AA Section A A Figure 30 Optical chamber and mechanical thickness Section B B Figure 31 Heat chamber heat sink and air gap APPENDIX A QUANTUM FILTER WHEEL Currently under development for Q1 2010 release is a four position Quantum filter wheel All the features and specifications of the standard Quantum are included with four independent filters on a rotating motorized wheel The familiar user interface of the Quantum is maintained with the wavelength of the currently selected filter displayed on the LCD Changing of filter position is accomplished with the red and blue buttons modally or via RS232 serial connection Due to slightly different thicknesses of each filter in the wheel a slight refocusing from position to position may be required under some circumstances Consult the factory if matched thickness is a requirement in your application There are no restrictions on the com
4. Alternatively examine the brightest features in the image and check for clipping where they lose detail and wash out On occasions of poor seeing sharpness may be valued over noise in which case it is worth abandoning a proper exposure and setting the exposure time artificially short This will serve to freeze the seeing Levels can later be brought up in post processing 30 It is important to save all images in a lossless format that does not discard fine details JPEG files while saving disk space cost dearly in their ability to preserve fine detail for later processing Always save images in the most raw lossless format allowed Good choices are FITS TIFF or the camera s proprietary raw format Newton s Rings Many digital image sensors suffer from a phenomenon known as Newton s Rings interference fringes or interference patterns These wavy lines are caused by reflections inside the image sensor Some cameras are more prone to the problem than others High end cameras sometimes show the problem worse due to the close tolerances of their manufacture effectively creating an etalon between two slightly reflective surfaces Unfortunately there are no hard and fast rules for knowing whether a camera will be susceptible before purchasing other than asking other users of that camera if they have encountered the problem The solution to the fringes can be quite simple tilting the camera detunes the reflections just as tilti
5. Dielectric hot mirrors reject by reflection rather than through absorption Therefore the mirror may sustain a greater energy load and result in less heat expansion than colored glass energy rejection filters The coating reflects UV and or IR energy as an optical flat mirror but passes visual light as an optical window Application of a dielectric hot mirror is appropriate in configurations for wavelengths lower than available colored glass windows such as Ca II K and Ca II H line as well as Cn Mg Fe XIV and HB lines The application may also be used when colored glass is not available in the desired clear aperture The dielectric hot mirror may also be applied as an additional level of energy rejection as colored glass does not block IR from entering the system Reflected light from the dielectric hot mirror reflects at opposite angle as encountered passing back through objective elements at the original incident angle and focus concentration The dielectric hot mirror may be introduced to encounter concentrated light near focus However it must be introduced prior to any optical 22 elements such as a secondary or diagonal mirror as those elements would be subject to stress loss of figure expansion and cracking due to excessive heat load Various dielectric hot mirrors designed to block UV or IR but pass visual light are marketed for photographic and astronomical applications as UV IR or UV IR cut filters Application of the hot mirro
6. 100mm before the O then the position of 02 is 400mm behind the negative lens and a net result of an additional 300mm in new back focus required Additional focus length constructed of long extension tubes usually unbalances the telescope and causes de collimation of the optical path through sagging of the focuser drawtube However introduction of the same 4X negative lens 10mm before O1 would create only 40mm behind the negative lens and a net 30mm needed in new back focus The simplest solution to this concern is to apply the negative lens farther back in the focus train specifically after a diagonal mirror 21 ENERGY REJECTION Energy rejection must be considered on all telescope applications of aperture above 50mm Excess radiation entering the telescope from UV Visual and IR light can cause excessive heat load to the instrument Without proper prefiltering even moderate apertures can cause a sufficiently large heat load to overcome the regulating capacity of the oven and cause the filter s CWL to drift off band or cause local seeing cells inside the telescope tube that blur fine details Larger amounts of excess heat in the optical assembly can cause optical elements to thermally expand and crack causing damage to the optical instruments Heat is also known to cause mounting cements to release and damage coatings or optical couplants which might be positioned in a location that encounters a focused or near focused beam Therefore any
7. applications in which precision CWL positioning is critical such as wing shift studies or in Ca Il K line atmospheric measurement applications The Quantum housing is also available as an upgrade to existing DayStar ATM and University Filters already in use Because DayStar Filters remain serviceable for many decades filters in operation now may be upgraded to the new Quantum electronics housing package The DayStar Quantum Bandpass filter is typically applied within the optical path of a telescope or heliostat system for observation of the Sun s image in certain narrow wavelengths These wavelengths are most often the strong Fraunhofer spectral lines of Hydrogen Alpha Calcium Il K Line Sodium D line s Calcium Il H Line Helium D3 line Hydrogen Beta and others Please refer to the DayStar catalog or website for a current list of available standard center wavelengths bandwidths and prices The bandpass filter is designed to block all light of the solar continuum but pass the desired narrow bandpass wavelength light emitted or absorbed by the desired element under study The Hydrogen Alpha wavelength of 6562 8 A Angstroms 1x10 m is chiefly used for photospheric chromospheric prominence and atmospheric study of the sun The DayStar Quantum bandpass filter is applied near the rear of the telescope or optical path rather than before the primary objective This application within the concentrated beam of the optical path offers seeing
8. assembling the mosaic Dynamic range and colorization Monochromatic light such as Ha appears during visual observation as various brightnesses of the same color Due to the enormous dynamic range of the eye both surface details as well as faint prominences can be seen Figure 22 Top left the uncolored raw image Top right colored pure red as seen by the eye Bottom left a gamma coding color simultaneously Image sensors do scheme brings out faint prominences Bottom right sharpening is not have the same dynamic range applied to accentuate faint and low contrast features capability and so with narrow FWHM filters it is typically necessary to expose for either Surface or prominences and then combine them A common technique is masking away the over or underexposed regions to allow another differently exposed image show through Another method of dealing with dynamic range is assigning various brightness regions to different colors If the gamma sometimes called midtone setting is set separately for R G and B of an originally monochromatic image then different features can be emphasized in different colors A high gamma setting for the red channel will bring out faint prominences A low blue and green gamma will highlight bright regions When the overall balance is adjusted properly a pleasing orange yellow image can result that shows prominences are deep red with surface as orange or yellow Regardless of exposure image
9. diameter Green normal operation filter on band Yellow filter warming up please wait Red fault or low supply voltage Five digit seven segment with decimal point LCD wavelength readout Up down buttons to change filter bandpass in 0 1 steps up to maximum of 1 0 offset Red button increases wavelength and temperature blue button decreases Button lockout can be enabled disabled by depressing both buttons while plugging in power cord RS232 computer interface for filter status and offset control Connection RS 232 serial port DB9 female connector 9600 baud 8 bits no parity 1 stop bit Communication protocol available from DayStar by request Electronics 10 30V DC power with 5 5x2 1mm jack Maximum current draw 2 0A Power use typically 10W at 12V Fully operational with reverse polarity AC wall adapter cord Worldwide 100 240V AC 50 60Hz 18W 6 foot cord with supplied ungrounded user interchangeable US Euro UK and Australian plugs Overvoltage and overcurrent protection Internal fuse Internal nonreplaceable surge absorber Protection against automobile alternator load dumps is provided but not guaranteed RoHS compliant lead free Temperature control Wing shift slew time approximately 8 minutes red shifting 10 15 minutes blue shifting dependent upon ambient temperature the Quantum does not contain active cooling Temperature regulation 0 5 C 0 05 A guaranteed typically 0 1 C 0 01 A Temper
10. eye can adjust to lower light levels Reflected light from the ground or objects below the telescope have a big impact on dark adaption White or light surfaces should be avoided in working areas for visual observing the sun through the Quantum Observers should consider the use of eyepieces with an eye cup and may also benefit from an eye patch or keeping the observing eye closed immediately before viewing Binocular viewing offers a great deal of added contrast for visual solar observing The nature of the way the human eye perceives contrast differently in different eyes as well as in different areas of an eye s peripheral vision adds contrast to the visual experience when two eyepieces are used Care should be taken with binocular viewer prisms Many prisms polarize light on reflection to the second eyepiece Rotation of the Quantum filter may be required to align polarity of the binocular viewer prism to balance the brightness in each eye 2 IMAGING CONSIDERATIONS Choice of camera go monochrome Successful imaging through the Quantum is strongly influenced by the choice of camera While just about any camera will produce an image with recognizable features large improvements in image quality can be obtained when matching the camera to the application The primary factor in image quality is that of choosing a monochrome camera over a color one Virtually all color cameras contain an internal Bayer color filter array that passes
11. hazard and so can be disposed safely Alternatively the filter can be returned to the factory for an upgrade replacement or for recycling 38 ADAPTER PLATES A variety of end plates are available to mate the Quantum to your equipment A list of popular plates is below followed by the naming standard Part GM2DT GF2SCTT GF 2SCT1 GM 1D1 GM 2D1 GM 2D2 Q3GF1F Q3GF2F Q3GFTF Q3GW1F Q3GW2F Q3GWTF Q3RFC1M Q3RFCTM RF 1D1 RF 2D1 RF 2D2 Description 2 drawtube snout Has male T threads and male drawtube Fits with Q3GFTF Female SCT to Male T adapter Fits with Q3GWTF Front Gold plate Front Female 2 SCT ring mount 1 375 x24 thread Front Male 1 25 OD snout Front Male 2 OD snout 1 375 x24 thread Front Male 2 OD snout SCT thread Quantum Front flat plate female 1 375 x24 thread Quantum Front flat plate 2 x24 thread Quantum Front flat plate female T thread Quantum Front WEDGE plate 1 375 x24 thread specify tilt angle Quantum Front WEDGE plate 2 x24 thread specify tilt angle Quantum Front WEDGE plate T thread specify tilt angle Quantum Rear Flat SCT Combo Plate w 1 375 x24 thread Quantum Rear Flat SCT Combo Plate w T thread Rear Female 1 25 ID drawtube 1 375 x24 thread Rear Female 2 ID drawtube 1 375 x24 thread Rear Female 2 ID drawtube 2 x24 thread Connects standard SCT thread to 2 drawtube Quantum plate naming standard Q3 Q4 GorR F or W MorF Body style
12. limited applications as it may be applied to a telescope system of any objective size The same Quantum may also be re applied under different applications on different telescope equipment and in different configurations Considerations in the configuration must be made to allow light to enter the Quantum filter at a normal angle of incidence This is accomplished by assuring the light cone is approximately F 30 on encounter with the Quantum filter The Fabry Perot etalon design offers sub angstrom bandpass transmissions of as narrow as 0 24 FWHM A precision tuned temperature regulated oven assures accurate wavelength transmission at all times The Quantum is able to transmit just one wavelength range and is restricted in tuning to 1 0A total in steps of 0 1A Figure 1 Visible spectrum Courtesy N A Sharp NOAO NSO Kitt Peak FTS AURA NSF SPECTRAL LINES Hydrogen Various wavelengths are typically isolated as they relate to Fraunhofer lines A majority of Quantum filters are applied in direct observation of the solar disk Absorption lines of Hydrogen are extensively used for observation of the chromosphere and prominences The Hydrogen Alpha Ha absorption line as observed from within the Earth s atmosphere has a width of approximately 0 8 A Due to the presence of other absorption and emission lines near Ha a filter of less than 1 0 A width is required in order to isolate Ha light from the solar continuum The narrower the FWHM
13. no headroom for brightness color or sharpening adjustments after the image is 29 captured 12 or 16 bit cameras preserve the data much more precisely allowing strong level shifts unsharp mask or other processing with no visible degradation of the image Field of view Some applications call for imaging of the entire solar disk in one field of view Other applications suggest a higher magnification and smaller field of view Field of view is an important consideration in selection of the telescope aperture mask and or negative lens to be used as the F 30 focal ratio usually results in very high magnification and a small field of view This is desirable for imaging of fine structure and study of specific features and details However those who intend to image the full solar disk should consider a focal reducer applied after the Quantum in order to reduce the focal length Additionally aperture reduction and lower power negative lens should be considered VOGA E i Leg kb j Le we e DS ha F arg A NV NW ui CN Lk Wi Ai a Figure 20 Imaging through a Quantum Courtesy Theirry Legault LI Exposure and File Type When operating the camera ideally one would set the exposure such that the image features are recorded brightly without clipping Expose to the right is a catchphrase referring to the practice of adjusting the exposure time until values in a histogram nearly touch the right bright edge
14. of the IR blocking often falls below the wavelength of H alpha resulting in a transmission of only a couple of percent A good monochrome camera is immune to all these effects As with the issue of some matching eyepiece focal length to the telescope focal ratio camera pixel pitch should also be matched to the telescope they will be used upon Pixel pitch is the width of each pixel in a camera sensor commonly from 1 to 30 microns For example if the diffraction limited resolution is two arcseconds it makes little sense to image with a plate scale of 0 5 arcseconds per pixel or below That would spread the light across too many pixels reducing the signal to noise ratio as each pixel has a noise contribution and limiting the field of view that would otherwise be obtainable Using the Rayleigh criterion in a similar way as was derived in the Visual Observing FR section one can obtain the relationship P 2 5 for H alpha light with a monochrome camera where P is the pixel pitch in microns 0 001 millimeter and FR is the focal ratio of the telescope This includes a consideration for information theory where it is necessary for two pixels to represent each feature For an F 30 light cone the diffraction limited pixel pitch is therefore 12um 0 012mm If one is limited to a camera with pixels significantly less than that size a focal reducer is recommended to better match the target size Alternatively it may be advantageou
15. rated for use in a vacuum at extreme temperatures or in the presence of radiation Filters for such environments are developed on a custom basis The Quantum filter is best stored in a sealed humidity controlled case containing desiccant Ideally the filter should be stored in a climate controlled environment of 73 F with humidity of under 20 This will increase the life expectancy of blocking filter elements within the optical assembly which age faster in heat and humidity Filters stored in such conditions have lasted in excess of 20 years The Quantum filter is very durable to shock impact The etalon crystal of the filter is seated deeply within many layers of glass in a metal cell which is air spaced inside an outer aluminum ring Extra caution is not required for shock resistance to a closed and fully assembled Quantum oven assembly The filter stack assembly however is very susceptible to damage should the optical housing be opened or tampered with The optical stack is housed under slight compression to maintain equal and even pressure between the optical layers over a many decade lifespan Often when that pressure is released air can enter the filter stack and or visible creases form in the lubricated cavities created with that release of pressure The result can be air bubbles and or spider veins in the assembly Damage occurs when elements are separated twisted pulled or slid against one another or even the release of 15 te
16. the undesired orders Finally a trim filter offers blocking of off band light by a factor of 1x10 from X ray to Far Infrared Colored or neutral density elements may also be added to the filter stack to reduce the transmission to a comfortable level if necessary Solid spaced etalons are fabricated by coating reflective and anti reflective coatings directly onto cleaved and graded mica crystal wafers The surface figure of the cleaved crystal is uniform to a molecular level The resulting surface figure wavefront properties stable solid mounting and homogeneity of the prepared etalon crystal assures continuous uniformity in CWL FWHM and transmission across the entire clear and usable aperture A light beam passing through the optical assembly will maintain the limiting resolution of the original light gathering aperture Mounted in a rear mounted collimated configuration the Quantum bandpass filter may be applied to instruments of any aperture and is therefore diffraction limited Etalon Center Wavelength The varying transmission function of an etalon is caused by interference between the multiple reflections of light between the two reflecting surfaces Constructive interference occurs if the transmitted beams are in phase and this corresponds to a high transmission peak of the etalon If the transmitted beams are out of phase destructive interference occurs and this corresponds to a transmission minimum Whether the multiply reflected b
17. Company Seuen ASTRO OPTICS DIVISION MONTPELIER MD 20709 2587 301 953 2000 e WWW COMPANY7 COM DAYSTAR FILTERS EN II White Paper Precision Optical Bandpass Filters for Solar Research and Observation Copyright 2009 DayStar Filters LLC All Rights Reserved Showroom 14300 Cherry Lane Court Laurel Maryland 20707 U S A Telephone 301 953 2000 URL www company7 com daystar Correspondence Box 2587 Montpelier Maryland 20709 2587 U S A E Mail info company7 com DAYSTAR FILTERS d Ae Z eh ZA ZZ E iNT en lt lt Ma sii mar e Fil Sa 2 Hydrogen Alpha Filter White Paper Precision Optical Bandpass Filters for Solar Research and Observation www DayStarFilfers com TABLE OF CONTENTS OVERVIEW paia 5 SPECTRAL LINES sleale 6 HVOFosgei a alia aa 6 dla 7 Gdl alc 8 lineari 9 Other Ingria ie 10 PRINCIPLESSOFOPERATION cara 11 Quantumiopticald sistovenVieW lia 11 Etalon CenterWavelenstia ssaa 11 Ernica 14 Etalon e ei E ON iaa 15 Environmental Considera tioNso ssaa 15 APREICA ON scaricare ete esate ae 17 Brett Bei aN EE 17 FOCUIPIONe melanina 17 Instrument choice and Considerationi cicale 20 BACK TOC srl iaia 20 ENERO REJECTION cta ai 22 Large aperture energy rejection Strategies rei 23 WOO fu ft nn E 24 CHE lee velica 25 VISUALE OBSERVA TON 55 A E dan Gain tag ted seeesainsse 26 EV EDICCE Selec illa 26 Maximine CONS trae 27 IMAGING CONSIDERATION Sais 28 Choice of came
18. ain the filter 2 are used to adapt to your telescope lt FRONT GOLD OUTER adapter plate f Delrin Containment plate do not remove J lt Delrin Containment plate do not remove f lt REAR RED OUTER adapter plate Figure 25 Quantum adapter plates see next chapter for available options Lifespan of blocker and trimmer elements is increased by storage of the filter in cool dry atmospheric conditions While not in use store the filter in a sealed compartment such as a ziplock bag or pelican style case with desiccant if possible While not in use keep both ends of the filter capped to protect from dust debris and fingerprints Optical surfaces are very difficult to clean as the optical components of a DayStar Filter optical stack are sealed in optical couplant which remains loose for many years This optical couplant surrounds the filter and cleaning attempts usually only re introduce this couplant onto the surfaces Dust on the gold and red side has very minimal effect on the performance of the filter Oily smears and fingerprints on the front gold surface impact performance and clarity DayStar offers a clean and check service for the filter Additional services include Blocker and trimmer element restoration etalon upgrade options and Quantum housing upgrade from earlier ATM and University models Undisturbed the lifespan of the fabry perot etalon is possibly unlimited Etalons have been known to survive
19. and proximity to other lines Very narrow FWHM and precise tuning is critical for proper isolation Le par 0 8 0 7 Helium D3 5875 6A Emission line 0 6 0 5 0 4 Spectrum of Sun 0 3 0 2 0 1 5860 5865 5870 5875 5880 5885 5890 Wavelength Angstroms Figure 6 Helium D3 spectrum Other lines Other lines in the chromospheric spectra are determined by the specific research goals proposed by any research application Other known lines of study include Mg I Fe XIV Cn and HB Not all Fraunhofer lines are suggested for study due to interference from atmospheric elements Fe XIV and Mg are common lines of study in the spectrum of the Corona Absorption lines of the coronal spectra vary greatly from that of the photospheric spectra DayStar can manufacture filters to custom wavelength and FWHM specifications for wavelengths from 3800 A to 7000 A Center wavelengths from 3500 A to 8000 A are available with restrictions 10 PRINCIPLES OF OPERATION Quantum optical design overview A multi element filter stack is assembled from various components Exterior surfaces are wave accurate or better AR coated BK7 glass The heart of the filter is a solid spaced Fabry Perot etalon manufactured with high finesse and low fringing that exhibits multiple high transmission peaks in successive orders with FWHM as low as 0 3 For FWHM s of 0 2 A two matched etalons are stacked A blocking filter of 10 A FWHM then blocks
20. as video cameras or webcams which capture many consecutive frames often offer higher quality results The high soeed camera captures dozens or hundreds of images which can be sorted and selected for sharpness Fast frame photography or lucky imaging can capture many frames and sort images for sharpness to discard images with poor sharpness and keep images with good sharpness values This process is called image sorting No stacking is required in lucky imaging Stacking images has a limited application in high magnification applications as the surface features photographed can move and change very quickly or be distorted from selected frame to selected frame by changes in seeing Stacking is only viable when hundreds of frames can be combined to achieve a very high signal to noise ratio so that very aggressive sharpening routines can be applied 25 VISUAL OBSERVATION Eyepiece selection A configuration which uses a negative lens to accomplish F 30 will have a very large focal length and low power eyepieces of 30 50mm are suggested for full disk viewing Higher power eyepieces are appropriate if the seeing supports higher magnification A configuration with aperture reduction will benefit from the same eyepiece choices as the telescope ordinarily uses Many modern style wide apparent field eyepieces are designed for fast focal ratio applications Viewing at long focal ratios with these fast focal ratio eyepieces usually results in vi
21. ated in telescope applications by a choice of methods Masking the aperture of a fast focal ratio objective will increase the focal ratio proportionally For example a 100mm F 15 objective reduced to 50mm will result in F 30 In this application the effective focal length EFL of the telescope is not changed Resolution is reduced however Refracting telescopes require an on axis aperture reduction When using a refracting telescope introduction of a negative lens in the optical path prior to the Quantum filter will also increase the operative focal ratio of the optical system proportionally For example a 100mm F 7 5 objective with 4X negative lens applied will result in F 30 In this application the effective focal length EFL of the telescope will increase proportionally as well Resolution will not be reduced A single element negative lens will typically offer adverse effects in light drop off vignetting and in radial bandpass FWHM widening from angular light at the outer diameter of the negative lens A multiple element telecentric negative is suggested Certain telecentric lenses barlows are commercially available in 2X 2 5X and 4X focal lengths One manufacturer offers direct coupling of telecentric negative lenses to the Quantum with T thread coupling A combination of aperture reduction and negative lens application may be necessary for the application depending on the telescope equipment under consideration in order to achieve the de
22. ature measurement accuracy 0 2 C 41 e Temperature control method PID Proportional Integral Derivative e Internal heater power setting 0 1 resolution PWM modulation with 1kHz switching frequency Power setting derated at high input voltages to limit supply current to draw 2 0A Environmental e Ambient operating temperature range of filter O C to filter operating temperature listed on label varies with etalon ranges from 30 to 70 C e AC wall supply 0 C to 40 C 20 80 humidity non condensing indoors only e Heater is NOT certified for use in vacuum and is NOT radiation hardened Physical properties e Standard clear and usable aperture 32mm 1 25 inches e Available clear and usable aperture 44mm 1 75 inches e All other apertures require custom machining of all components with considerable lead time e External dimensions excluding adapter plates 41 4mm thick 80 8mm wide 92 8mm deep e Weight excluding adapter plates 0 54 kg 1 2 Ibs e Housing material 6061 T6 aluminum Type Il anodized e Endcap material Black Acetal natural finish Mechanical drawings e All dimensions in millimeters drawings not to scale CAD model available in STEP or IGES format Light Transmission Direction Figure 26 Fully assembled mechanical housing No adapter plates optical or electronic components are shown 42 1098119 UOISSILUSUEI JUDIT e Figure 27 Front LCD control panel faceplate
23. bination of filters within the wheel If you already own any DayStar Quantum ATM or University Series filters they can be moved into the filter wheel at the factory Example possibilities include e University set H Alpha 0 4 A PE Calcium K 2 0 A PE Sodium D 0 4 A PE Helium D3 0 3 PE e Visual observer s set H Alpha 0 7 A SE Calcium H 5 0 A SE Sodium D 0 4 A SE spare e Prominence Doppler set H Alpha 0 8 A plus three H Alpha 0 5 A with wing shifts of 0 5 0 0 0 5 Preliminary specifications subject to change e Filter clear aperture 32mm 1 25 e Housing dimensions outside diameter 190mm 7 5 thickness 60mm 2 4 e Worst case filter to filter change time 3 0 seconds e Compatible with the same plates and snouts as the standard Quantum e Power requirement 10 30v DC 4 amps All four filters are powered simultaneously filter positions not in use remain powered for instant availability 46 APPENDIX B QUANTUM TURBO The standard Quantum is thermally tuned and as such requires eight or more minutes to wing shift to a new CWL For researchers requiring faster tuning while retaining the precision of the Quantum a new housing is currently under development The Quantum Turbo contains a motorized tilting mechanism to rapidly shift the CWL of the filter across a 1 range To maintain precision tuning control a high resolution angular encoder is standard Additionally the Quantum Turbo is heated pro
24. design A list of known occurrences is available from the manufacturer Newtonian and Dobsonian telescopes typically make poor candidates for application of the Quantum for solar viewing The focal point of a Newtonian or Dobsonian telescope is typically designed to fall within the basket or optical telescope assembly for the direct application of user eyepieces or cameras with little spare backfocus Introduction of the Quantum components require more focus travel than most Newtonians and Dobsonians permit Some Gregorian telescopes with adjustable secondary position have been used for application of the rear mount bandpass filter Figure 14 Off axis Energy rejection filter Maksutov telescopes can also suffer difficulties due to the large size of the secondary element Light passing predominantly through the outer diameter results in wing shift difficulties and bandpass broadening In any telescope system a number of concerns remain constant and must be considered Scattered light from internal surfaces within the optical tube assembly or reflections off poorly coated elements can result in transmission of off band light through the Quantum filter and decreased contrast Added weight of equipment to the rear of the telescope can also cause flexure in weak telescope components which may not be designed for the Quantum filter and 20 associated accessories As the introduction of a negative lens increases the telescope focal length th
25. e it was off the market for a short time it has recently returned to production Exposures vary based on individual filter transmission percentage A good range while operating at F 30 through the DayStar Quantum is 1 15 sec to 1 60 second Most astronomers choose to roll from a bulk film spool due to film availability Development of the film in a personal darkroom is usually necessary as well Agfa Rodinal developer is preferred to obtain maximum contrast It should be noted that Dmax and bit depth must be considered in scanners for best results 33 SAFETY Looking at the sun is inherently dangerous so care must be used at all times Never leave a solar telescope unattended Always replace the front cap of a solar telescope while not in use Unfiltered focused light can create a fire Unfiltered focused light can cause blindness Unfiltered focused light can damage equipment and cause swelling to optical elements causing them to bind in their cells and break Optical components are heavy and if not properly attached and tightened down they can fall off while in use and cause hazard to those around the equipment NEVER VIEW THROUGH A TELESCOPE WITHOUT THE TELESCOPE FULLY CONFIGURED USERS MUST USE CAUTION AROUND THE TELESCOPE WHILE CONFIGURING OR CHANGING COMPONENTS OF A PARTIALLY INSTALLED CONFIGURATION THE QUANTUM IS NOT DESIGNED FOR USE WITHOUT ENERGY REJECTION 34 OPERATION 1 Plug the unit in The digital LCD screen wil
26. e optical tube assembly and the associated negative seeing affects Light passing through the off axis aperture mask will result in light exiting the telescope s optical path off axis In consideration for the exit angle of light from the off axis SCT a small wedge plate is applied to the front of the Quantum A wedge plate of a 1 6 angle is required for telescopes with focal ratios of F 8 10 A wedge plate of 1 4 is required for telescopes with focal ratios of F 12 15 The angle of this wedge plate must be aligned to the orientation of the off axis aperture mask 19 Instrument choice and consideration The Quantum filter may be used in a wide variety of telescope configurations Selection of the ideal telescope should include consideration for desired focal length and resolution Low focal length applications require aperture reduction High focal length high resolution goals suggest application of a negative lens to achieve F 30 As the function of the Quantum is to pass only a very small wavelength range of light it is not necessary to use optics with quality color correction Apochromatic telescopes do not offer significant advantages over achromats except perhaps for field flatness Back focus In focus and back focus is a concern for successful configurations Occasionally in reflector applications a telescope may fail to have the necessary in focus needed to introduce the Quantum These are very uncommon outside of the Newtonian
27. e over irregular objects such as trees or buildings can also adversely affect seeing Laminar air flows move evenly over smooth surfaces such as open fields and bodies of water Large bodies of water also sink solar radiation away from the surface and improve seeing conditions above Seeing cells in the upper atmosphere are not affected by local circumstances Ice crystals in the upper atmosphere high cirrus clouds the jet stream and water vapor affect seeing regionally A telescope of arcsecond or sub arcsecond resolution may not be capable of obtaining this resolution if either local or regional seeing does not support the atmospheric clarity Thermal cells can affect focus It is therefore necessary to focus very slowly and to consider seeing variations while focusing the telescope or imaging system Fluctuations in seeing will most certainly affect the sharpness of an image captured Visual observations at high resolution may succeed due to the human eye s ability to sort and process occasional lucky seeing cells Still photography using telescopes which exceed the local seeing circumstances and only a small number of exposures are very unlikely to exceed local seeing conditions In general for areas of less than exceptional seeing conditions a daytime seeing limit of 90mm in aperture is accepted However when imaging in multiple exposure or fast frame photography that seeing limit no longer applies High speed capture methods such
28. eams are in phase or not depends on the wavelength of the light in vacuum the angle the light travels through the etalon the thickness of the etalon and the refractive index of the material between the reflecting surfaces 11 100 90 80 70 60 50 40 30 20 Finesse 17 Finesse 90 DayStar 0 3A Etalon Transmission 10 0 6525 6530 6535 6540 6545 6550 6555 6560 6565 6570 6575 Wavelength Angstroms Figure 7 Etalon finesse The reflectivity of the etalon coating determines the finesse of the etalon and consequently the FWHM Higher finesse etalons show sharper transmission peaks with lower minimum transmission coefficients The average finesse of a DayStar etalon is 55 with finesses up to 90 employed for special applications l 50 0 6562 0 6562 2 6562 4 6562 6 6562 8 6563 0 6563 2 6563 4 6563 6 Etalon Transmission Wavelength Angstroms Figure 8 FWHM means full width at half maximum 12 A Fabry P rot etalon changes peak transmission wavelength with changing distance between the reflective sides This can occur by a change in temperature through thermal expansion of the mica wafer In order to maintain the center wavelength CWL of the Fabry P rot etalon in conditions of varying environmental temperature a consideration for tuning must be made An increase in temperature causes an increase of the CWL of transmission peaks The etalon varies 1 0 per 17 0 F 9 4 C The Quantum
29. emperature the filter will be red shifted Below zero the heater may not have sufficient power to raise the filter to operating temperature For subzero operation bring the filter inside let it reach its wavelength setting then quickly take it outside and reconnect power The heater can maintain an already warm stack at much lower ambient temperature As the Quantum contains electronics it should not be operated in the presence of moisture such as dew or rainfall Always store the filter in a cool dry place preferably in its case with desiccant Blockers amp trimmers age with humidity so careful storage will extend its life beyond the nominal 10 year expectation For remote control of the Quantum a Windows compatible software package is available from DayStar QuantumControl is a full featured graphical monitoring and control package QuantumCommand included in QuantumControl offers command line control for integration into scripts For users of non Windows computers the serial protocol specification is available for programming your own interface solution 0 5 oan SE Hydrogen alpna 6562 SA 6562 8 Hydrogen alpha get EE 6563 0A Wing shift 0 2A red 6558 0A 6560 0A 6562 0A 6564 0A 6566 04 Current 6562 3A Heating Figure 24 Quantum Control software for Windows Consult the user s manual for further details 36 CARE AND STORAGE Each DayStar Quantum has 4 end plates 2 are used to cont
30. ermined maximum magnification can be calculated The average resolving power of the naked eye is approximately 60 60 arcseconds Therefore magnifications increasingly above o will look progressively blurrier due to diffraction Personal visual acuity experience and taste cause this to be a guideline rather than a rule The minimum recommended eyepiece focal length can then be expressed as gt where FL is the telescope focal length including any barlow The previous expression can be further simplified to the very handy relationship of EpFL 2 75 FR where EpFL is the optimal eyepiece focal length and FR is the telescope focal ratio Eyepieces near this value will fully exploit the available resolution of the telescope Conservatively rounding down the 2 75 focal ratio factor to 2 for margin indicates that at F 30 eyepieces shorter than 60mm outresolve the diffraction limit and offer little or no benefit for well sighted observers For the sharpest and brightest looking image use as wide an eyepiece as possible Employing eyepieces far below the guideline such as 25mm or 12mm will result in a disappointingly blurry and dim image Maximizing contrast Dark adaptation is important for solar observing The 4 12 transmission of the Quantum will require a certain degree of dark adaptation in order to maximize the full contrast of the sun s image Observers will want to consider sun shades dark cloth drape darkened or shaded areas where the
31. fire and rocket crashes with minimal effective damage if left undisturbed in the optical assembly However opening of the optical stack and separating the fabry perot etalon crystal from its proper seating will cause irreparable harm The release of pressure to an optical assembly unscrewing the plastic Delrin plates can cause the introduction of air into the filter and cause permanent veining of the seated etalon crystal Each crystal is individually tuned with custom built spectroscopic tools only available within the DayStar Filters Laboratory There are no user serviceable or optician serviceable parts within the DayStar Filters optical assembly Opening a DayStar Quantum filter voids the factory warranty Do not bake the Quantum in an oven or other high temperature apparatus The Quantum contains a thermal fuse that will open if the optical stack reaches a temperature higher than its safety rating approximately 180 F 37 The Quantum includes built in fault checking Should one of the following error codes appear on the LCD please take corrective action dEAdb Dead battery input voltage is less than 8 VDC LObAt Low battery input voltage is less than 10 VDC HIGHV High voltage input voltage is more than 30 VDC OPEnt Internal wiring fault please return to DayStar for repair SHOrt Internal wiring fault please return to DayStar for repair Disposal The Quantum is RoHS compliant contains no lead and is not an environmental
32. ght FWHM standard tolerance 0 0 0 1 for standard products 0 05 for custom FWHMs under 1 Professional PE grade CWL uniformity the mean peak wavelength of all 12mm diameter areas shall lie within 0 1 angstroms of the full aperture wavelength measurement Standard SE grade CWL uniformity is not guaranteed but is typically kept within 0 5 angstroms of the full aperture measurement Fully blocked transmittance 4 12 of polarized light Lower values correspond to narrower bandwidth filters High finesse low fringing steep transmission peak Broadband blocking filters 1x10 from X Ray to Far Infrared All exterior or air surfaces are Broadband AR coated Substrate Material BK7 Flatness 1 4 wavefront or better Parallelism 3 5 arc minutes or better Scratch Dig 60 40 Soft waveplates are contained within the optical assembly Fabry Perot etalon Solid state etalon fabricated on cleaved mica wafer Optical assembly thickness e Usually near 23mm but can range from approximately 14 25mm e Slight variations in optical thickness can occur due to variations in component materials required throughout the construction process e For the purpose of ray trace simulations the optical stack may be modeled as a BK7 window of clear aperture 31 75mm and thickness 23mm e The optical stack is sandwiched in the housing by Buna N O rings to provide compression User Interface Red yellow green LED status light 3mm
33. ging of emission lines of the spectrum or where large aperture is being used to accomplish high resolution Introduction of a neutral density filter may be called for Transmission percentages of a Quantum are 4 12 of polarized light so orientation of polarizing neutral density filters may affect net transmission Introduction of the polarizer should be after energy rejection or after the Quantum Neutral density filters are subject to overheating and damage if exposed to full spectrum concentrated light CCD photometer and Photomultiplier tubes may require reduction of transmission due to sensitivity Aperture reduction should be considered first but if reduction is not an option a neutral density filter may be applied 24 ATMOSPHERIC SEEING Local seeing conditions are usually the determining factor in the limiting resolution of the telescope system Daytime seeing cells are of serious concern and should be considered early Daytime seeing is affected by changes in temperature within the atmosphere between the sun and the observer Most seeing impact occurs in the lowest 30 feet above the ground As surfaces absorb solar radiation throughout the day that radiation is continually released into neighboring air Dark colored surfaces absorb more heat than light colored surfaces Asphalt roofing shingles concrete dark buildings brick and pavement all impact local seeing significantly Grass impacts local seeing the least Air flow and turbulenc
34. gnetting and poor exit pupil matching Telescope diffraction limited resolving power as modeled by Dawes limit the Rayleigh Criterion and others is also a concern when operating at F 30 High powered eyepieces which exceed the resolving power will produce negative effects The eye has more difficulty distinguishing large scale low contrast features than small ones Image brightness will be negatively impacted as the light is being spread unnecessarily thin without any finer details becoming visible Focus at high magnification can also be very challenging as the chromosphere softens the limb of the sun It is important to include time to incorporate seeing changes in the focusing process to avoid ill effects Figure 16 Visual observation through a refractor A The Rayleigh Criterion is expressed as follows sin 8 1 22 where is the angular resolution A is the wavelength and D is the diameter of the telescope aperture If the telescope is stopped down the stopdown aperture should be used in calculations not the full masked aperture For Ha solar observing the criterion can be simplified to O 165 D resolution expressed in arcseconds As an example a telescope of 100mm aperture where D is the telescope aperture in millimeters and 0 is the diffraction limited 26 would not be expected to reveal details smaller than 1 65 arcseconds in extent unless they are very high contrast Once the limiting resolution is det
35. ications of less than 1 0 FWHM Applications of 2 0 and wider filters can tolerate two degrees of tilt and should therefore be configured with a focal ratio of F 15 or above 13 Etalon Uniformity The solid substrate of Fabry Perot etalon crystals ensures a higher figure surface quality on which coatings are laid Naturally grown high grade optical mica is used for its properties in cleaving The crystal structure of mica can be described as being a series of parallel sheets so that it may be cleaved into parallel layers to a molecular level Mica wafers must be cleaved by hand with consequent yield loss due to the tendency of mica to jump layers which can cause a Figure 10 Raw mica step in CWL Mica wafers are graded for homogeneity within the structure of the sample Natural mineral formations generate areas of higher and lower concentrations of elements altering the index of refraction across the sample Candidate etalons are selected for areas of maximum homogeneity across the sample aperture needed to construct the etalon crystal Areas larger than 50mm of homogeneous uniformity are extremely scarce Once coated with reflective and anti reflective coatings to amplify the finesse and migrate the transmission peak to its desired wavelength etalon crystals are seated with high temperature rated optical couplant in wave BK7 optical windows In order to prevent damage to the crystal in any future servicing of the filter
36. is can also cause the object to move significantly back in the focus train The associated weight of the Quantum and accessories is of greater concern at greater extension of a telescope focusing tube Flexure of the focusing tube can cause loss of collimation of the optical system shifting the CWL of the filter bandpass lower Introduction of a negative lens and the position in the optical path in which the negative lens is introduced will greatly affect the subsequent back focus needed The impact of the increased focal length is lessened when the negative lens and subsequent Quantum filter are introduced farther back in the optical path Typically an introduction after a diagonal will significantly reduce the length of the telescope and the associated weight and flexure of the telescope and focuser tubes The relation between the amplification factor A the focal length Fg of the Barlow lens and the distance D between the lens and the object is A D Og 1 FOCAL PLANE Apparent original new Telescope position Ohiocti of objective new Paro Objective focal length Distance of Earlow inside original focal plane istance of Earlow inside new focal plane Apparent focal length objective plus Barlow Figure 15 Barlow lens changes position of focal plane As Focal Length and O is a function of distance from the object it is therefore important to consider the location where the negative lens is introduced Ifa 4x lens is introduced
37. l scroll the Quantum s specification and uniformity grade The Quantum will then display the CURRENT CWL being transmitted A yellow light indicates that the unit is on but moving to or settling on the desired wavelength As the unit heats the display will change as heat causes the CWL transmitted to increase It will reach the wavelength programmed and the CWL readout will cease to increase The light will remain yellow while the heat diffuses throughout the glass Wait for it to heat up The orange light will turn green when it has settled at the desired wavelength 2 Find the sun At long focal lengths the sun moves fast Don t look through the unfiltered scope to find the sun Look at the shadow of the telescope or use a dedicated white light filtered finderscope or other dedicated solar finder 3 Adjust the focus until the sun is sharp If you cannot reach focus make sure any diagonal is before the barlow or Powermate not after In extreme cases extension tubes may be needed before the barlow 4 Once the LED on the front of the Quantum turns green determine if the image is on band by comparing the leading and trailing hemispheres of the Sun If one side shows more detail then the other the filter is slightly off band If the Sun is a featureless disk a more aggressive adjustment may be needed or part of the optical train may be tilted A sag of 1 0 1 5 degrees is common with inexpensive focusers and can blueshift the Quantum up
38. metal housing diameter Quantum standard aperture Quantum 2 aperture Gold or Red side sun or eye side Female 1 375 x24 thread for 1 25 snout Female thread for 2 snout Female T thread M42x0 75 Combo SCT 2 x24 male thread with female thread for 1 25 snout Female T thread M42x0 75 with male SCT thread 2 x24 Male or Female threads Quantum snout naming standard GorR MorF Gold sun or Red eye side Male or Female OD or ID if male or female of tube D or SCT Draw tube or SCT tube 1 or 2 or T Thread of snout which attaches to filter s plate 39 SPECIFICATIONS Standard Center Wavelengths amp Bandpasses Hydrogen Alpha CWL 6562 8 A FWHMs 0 3 0 4 0 5 0 6 0 7 0 8 Calcium Ca II K CWL 3933 7 A FWHMs 1 0 2 0A Calcium Ca II H CWL 3968 5 A FWHMs 1 0 5 0 Sodium Na D CWL 5895 9 or 5889 9 specified at order time FWHM 0 4 Helium He D3 CWL 5875 62 FWHMs 0 3 0 5 Custom Center Wavelengths DayStar can manufacture filters to custom wavelengths from 3800 to 7000 Center wavelengths from 3500 to 8000 are available with restrictions Common lines ordered by customers Hydrogen Beta 4861 3 A Iron XIV 5302 9 Cyanogen 3883 2 Magnesium b1 5183 6 Custom Bandpasses Custom FWHM s available from 0 2 to 10 0 A Tolerances and Homogeneity 40 CWL standard tolerance 0 1 for zero degree incident li
39. ng an etalon detunes the center wavelength For this reason DayStar offers the T threaded Interference Eliminator accessory to effect a controlled tilt of up to five degrees which is sufficient to abate the problem on all but the most seriously affected cameras Figure 21 Newton s Rings with camera normal left and tilted right Mosaicing Often when imaging at very long focal lengths and high magnification it becomes necessary to tile the image and generate a composite In this application inhomogeneous areas of the SE grade substrate of the etalon crystal will become noticeable Areas of slightly lower and higher CWL or wider and narrower FWHM will appear in an image as slightly lighter or darker areas When tiled together in a composite these areas become more apparent due to their repetition 31 PE grade etalon crystals will tile with much more accuracy A PE grade etalon crystal can however still display very slight variations in brightness while still operating within the technical tolerance of its bandpass and wavelength uniformity if aggressive processing is applied To remove these slight variations in brightness a flat field is recommended Defocusing the telescope or covering the front aperture with a diffusing material sufficient to remove any trace of features on the Sun will provide the best flat field Then raw images should be divided by the flat field in any popular astronomical imaging program before
40. nsion in opening the filter assembly That motion causes sections of the coating to slide clump or vein in effects as light as crackling or severe as complete coating failure Undisturbed etalon crystals have been found to last in excess of 30 years with no aging or degradation 16 APPLICATION Careful attention to the focal ratio of light passing through the Quantum filter is necessary for the filter to perform to specification Two methods of application are typically employed Pupil plane Large aperture or professional applications often involve a pupil plane configuration where light from the telescope is recollimated back to infinite focus through lenses on an optical bench or assembly This is functionally equivalent to placing the filter in front of the objective but with the advantage of squeezing a larger aperture through the 32 or 45mm clear aperture of the Quantum After the filter focusing optics are used to bring the light beam back to an appropriate focal length for observation Besides the aperture advantage this allows for an arbitrary plate scale at the imaging sensor to achieve the desired field of view CWL tuning and wavefront accuracy requirements are more stringent for pupil plane versus focal plane applications Therefore when ordering a Quantum for use in a pupil plane application be sure to note this on the order or in discussions with DayStar so that the appropriate testing procedures are performed at the factory
41. only one of red green or blue light for any given pixel Only 1 in 4 pixels have red sensitivity A color camera advertised as 16 megapixels performs as a 4 megapixel camera on H alpha or Calcium for example Additonally the color filter in the camera may have a cut point near H alpha or Calcium reducing the sensitivity A monochrome camera of Figure 17 Raw H alpha image from a Canon EOS 5D sensor Only 1 in 4 pixels is sensitive to red light the same specifications would have four times the resolution and more sensitivity Color cameras frequently internally average or smooth adjacent pixels to reduce noise further compounding the loss of resolution Resolution robbing compression is also Standard in low end color cameras producing JPEG or video files In most cases color changes are recorded at only half the resolution of brightnesses Color cameras also must RGB Inside the Camera Millions of i light sensors gt d I a MS gt lt AA S 4 d e fr D L 7 y 3 Sf 7 x E i t gt a Figure 18 The construction of a color camera includes a number of photon robbing features 28 Incoming Visible lig ht Visible Light passes through IR Blocking Filter Color Filters control the color light reaching a sensor Color blind sensors convert light reaching each sensor into electricity contain form of infrared blocking Unfortunately the cut point
42. optical surface which encounters a concentrated beam should be protected from excess radiation via an Energy Rejection Filter ERF As a great deal of heat is generated in UV colored glass is commonly used as a pre filter before a telescope s objective in order to cut UV light as well as light below the cut point of that color of glass Typically a red colored optical window will cut all light below 6000 A A yellow glass optical window will cut all light below 5000 A A red or yellow colored glass window ERF may not be used when attempting to pass wavelengths less than the corresponding ERF color such as Calcium II K Line found at 3933 A As colored glass optical windows reject by absorption they may not be applied within the optical plane behind the front objective Should a red glass ERF be introduced at the rear of the light path thermal expansion of the glass would cause it to grow in its cell and break A colored glass ERF pre filter mounted before the objective should be manufactured to the same or higher figure tolerances to the objective for which it is applied Consideration should also be made for the glass thickness ratio of the substrate in order to assure its flatness is maintained and the glass does not experience flexure from sagging An ERF with a figure will cause aberrations in the resulting images through the instrument Some instrument configurations suggest the introduction of a dielectric hot mirror for energy rejection
43. ot mirror towards the rear of the optical path before any optical element which would encounter concentrated light This includes the negative lens a diagonal a field flattener or neutral density filter Telescopes of extremely large aperture such as those over 500mm will require the application of neutral density film applied before the primary of the telescope or a complicated heat dump system to reject light outside of a narrow field of view Films are commercially available which reduce transmission across the entire spectrum by approximately 50 when applied as a pre filter The light gathering capacity of the very large objective assures that sufficient light volume will be passed through the Quantum for research purposes After the neutral density pre filter a dielectric hot mirror is suggested in addition mounted before any elements which encounter a concentrated beam A heat dump or heat stop typically consists of a reflective disk or cone with a central perforation located very near the focal point of the primary mirror in a professional telescope A portion of the Sun s disk is allowed to pass through with the majority of the Sun s light reflected away either back out or to the side sometimes into a purposely designed heat dump to dissipate the heat in a manner that will not affect seeing inside the instrument 23 Too much light Occasionally transmission is too high through the Quantum for certain applications such as CCD ima
44. r coating tends to deform the figure of the substrate on which it is applied Most large area products termed as hot mirrors are produced on borofloat glass in thicknesses of only 2mm 3mm The surface flatness of such hot mirrors is therefore usually too irregular to use as an energy rejection prefilter Astronomical UV IR cut filters manufactured with this coating in 1 5 and 2 circular aperture have far superior wave front tolerances which may be introduced into the optical path without impact The cut points of UV IR cut filters often occur near or at 4000 and can obstruct or attenuate transmission of 3933 or 3969 Calcium lines Care should be taken in selection of UV cut filters for these applications Large aperture energy rejection strategies In certain applications of large telescopes where a clear aperture greater than 150mm is planned for use energy rejection becomes a more serious issue Colored glass which is typically used for energy rejection is not available in large aperture and thickness As front mount glass must maintain a surface figure the energy rejection filter must be made to at least 1 10 thickness in order to maintain a quality surface figure Application of this large and heavy optical cell is also prohibitively heavy for mounting in the front of the telescope s objective Therefore alternative applications are appropriate Refracting telescopes of larger than 150mm aperture may introduce a dielectric h
45. ra go MONOCATOM EE 28 FEITO VIEW orn TT 30 EXPO SUG Mae UDS e Ee 30 Newton S RINES Sara 31 MOSCA a E 31 Dynamic range and colorization ii 32 ACULANCE ANA Presenta ani 33 PPP e e ES E nn 33 SARE 34 OPERATO iii ei 35 CARE AND STORAGE iaia er 37 ADAPTER PLATE porrie UA En PI A 39 SPECIFICATION KEEN 40 APPENDIX A QUANTUM FILTER WHEEL 46 APPENDIX B QUANTUM TURBO x aaa 47 Copyright 2009 DayStar Filters LLC All Rights Reserved OVERVIEW Developed by Del Woods in the early 1970 s the DayStar Filters product line has remained a mainstay of academic research for over 30 years Now the DayStar Quantum takes a step forward with state of the art electronic controls DayStar filter assemblies offer seeing limited application as they are adaptable to a great variety of telescopes or optical laboratory configurations Superior quality optics ensure a quality and homogeneous sub Angstrom bandpass transmission over the entire field of view Ultra narrow transmissions down to 0 2A in a single unit make the Quantum a viable option in applications which would otherwise require a Lyot style filter for research with a much faster production time and cost consideration Quantum electronics are ideal in remote and dedicated viewing applications where the filter requires remote tuning and or operation via serial interface The accurate CWL reporting and 1 0A CWL tuning feature also offer great benefit for research
46. s are more pleasing to the eye when a range of colors are used Changing color in addition to brightness greatly expands the dynamic 32 range that can be presented on screen or in print better making use of modern 12 or 16 bit image sensor data Acutance and presentation Not only is it important to match the image sensor pixel pitch to the diffraction limit it is also important to match the displayed size to the reader s eye and to properly sharpen an image The two images below demonstrate two different plate scales using the same raw image file One appears crisp and engaging one appears disappointingly soft and featureless They are the same image but sized differently Oversampling the image to the eye by printing the image too large is just as costly as a poorly matched camera or eyepiece Figure 23 Oversampling reduces perceived resolution Equally important to maximizing the information an image has to offer is acutance the sharpness of edges in an image By applying an unsharp mask with a radius comparable to the size of seeing blur or diffraction in an image the eye can perceive smaller finer details that are otherwise invisible Film imaging Film imaging in Hydrogen alpha is still a viable option for still photography The gradient depth of film is still superior to current CCD technology The ideal film choice is Technical Pan 2415 black and white negative film It has been used in research for many decades and whil
47. s to bin 2x2 or 3x3 pixels together As the pixels do not contain differing information the averaging will significantly reduce noise and allow more aggressive sharpening techniques without any real loss of resolution The next consideration in choosing a camera is that of frame rate The faster the camera can acquire frames the better your chances of beating the seeing through lucky imaging Cells of steady air are fleeting and few so a high frame rate is needed to maximize the chances of catching them and obtaining sharp Sharpness 0 1 2 3 4 5 6 7 8 Time Seconds images Frame rates of 10 Figure 19 Atmospheric seeing varies quickly in this 12fps data session to 60 frames per second are ideal Cameras with slower rates will have to settle for less than ideal seeing conditions or be exposed repeatedly for tens of minutes to obtain a sharp frame under poor seeing conditions Closely related to frame rate is the issue of transfer speed Parallel printer port USB 1 0 or other old technologies are a poor match for solar observing Even if the image sensor is capable of a fast exposure a slow interface will limit the real world achievable frame rate Gigabit Ethernet GigE USB 2 0 or 3 0 CameraLink or Firewire are all appropriate interfaces for a solar camera Bit depth is a crude measure of the dynamic range of a camera but is a good indicator of how far images will be capable of being processed 8 bit cameras offer little to
48. sired effective focal length and image size Both functions are in directly proportional scale and may be easily computed A focal reducer or positive lens may be applied after the Quantum filter in order to reduce the effective focal length should a smaller image size be desired for visual or photographic applications Resolution is not affected by introduction of a focal reduction lens SCT sized focal reduction lenses may be coupled directly to the Quantum as it is 18 manufactured with a standard rear SCT male thread However any non telecentricity of the barlow will be amplified limiting the usable field of view unless care is taken in the selection of the barlow F 5 F 15 LIGHT ENTERS FILTER AT ANGLE Barlow gt F 8 WITH 4X BARLOW F 32 F 10 WITH 3X BARLOW F 30 lt Filter gt REDUCED APERTURE MASK F 30 Figure 13 Angle of light entering the filter should be at F 30 When using larger aperture reflector telescopes an aperture reduction mask and an off axis energy rejection pre filter is suggested Unfiltered full spectrum sunlight should not be allowed to enter a large aperture closed tube SCT telescope or overheating and damage may occur Concentrated light which encounters the secondary mirror will cause heating and possibly adhesive failure to the secondary mirror which would cause it to fall onto the primary mirror Sunlight entering an unprotected SCT telescope also causes convective heating inside th
49. such instance two unique filters are manufactured Images taken simultaneously may be compared to extract dynamic speeds on the solar surface 0 9 0 8 0 7 0 6 0 5 0 4 Spectrum of Sun 0 3 0 1 Sodium D2 Sodium D1 5890 0A 5895 9A 5878 5883 5888 5893 5898 5903 5908 Wavelength Angstroms Figure 3 Sodium D spectrum Calcium Calcium offers TWO strong absorption lines at 3933 A and at 3969 A known as the K and H lines Researchers have historically avoided the H line for academic research as it is very close to the Hydrogen e line For purposes of clarity in isolating Calcium and because imaging sensors offer similar sensitivity to the K and H lines of Calcium the K line has to date been the target of choice in Calcium filters Because the blue Calcium K Line 3933 A is sensitive to magnetic fields magnetically active structures show up in high contrast against the surrounding chromosphere Places where moderate magnetic fields exist show up bright whereas images of high magnetic fields are dark These studies have been instrumental in determining depth of the solar atmosphere and the study of spectral line formation without the assumption of local thermodynamic equilibrium LTE Calcium K 3933 7 Spectrum of Sun 3920 3925 3930 3935 3940 3945 3950 Wavelength Angstroms Figure 4 Calcium K spectrum Calcium H 3968 5 Spectrum of Sun 3954 3959 3964 3969 3974 3979 3984 Wavelength Angstroms
50. the greater isolation of desired wavelength and the greater the effective contrast in the observable image through exclusion of continuum and Doppler shifted light 6 A filter of FWHM 1 0 or narrower is required to observe prominence detail A filter of FWHM 0 7 A or narrower is preferred to observe prominence detail and spicule Light emitted from prominences typically travels at such velocity as to exhibit wing shift in red or blue wing As filter bandpass is reduced less wing shifted light emitted from prominences is allowed to pass and detail becomes finer in structure Filters below 0 5 FWHM typically do not reveal as significant prominence structure A filter of FWHM 0 5 or narrower is suggested to observe surface structure of the chromosphere while still revealing prominences A filter of FWHM 0 4 or narrower is required to observe the chromospheric network A filter of FWHM 0 3 is typically used only in research applications for examination of surface and prominence structure with wing shift effects eliminated Spectrum of Sun Hydrogen Alpha 6562 8 6548 6553 6558 6563 6568 6573 6578 Wavelength Angstroms Figure 2 Hydrogen Alpha spectrum NSO Kitt Peak FTS data used here were produced by NSF NOAO Sodium Sodium Na offers two absorption lines very close together at 5895 9 and 5890 0 Filters are manufactured to isolate one or both of these lines for the purpose of Doppler wing shift testing In
51. the optical couplant properties must permit it to remain viscous and transparent for 20 years or more Once the etalon crystal has been seated in BK7 windows it cannot safely be separated or un seated without risk of damage to the crystal Etalons seated in this manner are not affected by changes in atmospheric pressure associated with altitude Etalon crystals are characterized We and graded by a 1 meter focal length EHE Oe spectrometer with a custom built X Y scanning stage to map the distribution of nonuniformities Etalons are graded at full aperture and at reduced aperture sample areas for CWL and bandpass testing For PE Professional Edition grade etalons the mean peak wavelength of all 12mm diameter areas is specified to lie within 0 1 angstroms Completed Mouse 6548 67A 0 72 Spectrometer 650 794 Dark Cal Yes White Cal Yes Motor stopped Encoder 860 Exposure 0 9000 sec Gain 13 648 of the full aperture wavelength Figure 11 Uniformity testing a 2 etalon measurement Less than 5 of etalons qualify to PE grade SE Standard Edition grade etalons do not have a guaranteed uniformity but operationally are kept within 0 5 angstroms of the full aperture measurement 14 Etalon Stabilization As thermal expansion of the core mica crystal will cause the CWL of the etalon to vary regulation of the etalon temperature is necessary for precision control over wavelength The Quantum uses an aluminum ring surrounding
52. the optical stack to maintain an even temperature and transmission CWL The low thermal conductivity of glass dictates that heat will radiate through the entire optical stack slowly from the outer diameter in towards the center of the aperture During the time when the unit is heating or cooling the CWL in the center of the aperture will be at a different CWL than at the edge of the aperture The temperature sensor used for indication of temperature and CWL is located on the outside of the optical stack Therefore the indicated wavelength on the LCD will differ from the CWL passed through the central core of the filter while it is heating and or settling During this time the LED light on the Quantum faceplate will be orange A green LED light will indicate when an appropriate amount of time has passed in order for the temperature to settle throughout the unit When moving down in wavelength additional time may be required if ambient air temperatures are high as the Quantum uses only passive cooling For applications requiring rapid tuning the only feasible method of tuning is tilt DayStar manufactures manually thumbscrew tuned filters under the T Scanner and Quantum 2 TS 2 line of filters A precision motorized tilt version of the Quantum is under development for possible future release to researchers needing near instant tuning Environmental Considerations The Quantum is intended for use in normal atmospheric conditions and as such is not
53. to 0 5 A Tighten all connections and recheck the Sun s image If sag cannot be eliminated red shift the Quantum 5 If needed CWL tuning is accomplished by pushing either the red or blue buttons multiple times until the desired setting is flashed Then the display will revert back to the current CWL Once the LED goes green the Quantum has settled at the new CWL Settling time is approximately 8 minutes for the 32mm clear aperture Quantum Settling time for larger aperture Quantum filters is significantly higher as much as 45 minutes for a 50mm filter moved a large amount Cool down time when blue shifting varies based on environment and airflow over the filter as the Quantum does not contain active cooling 6 Note It is possible to disable the front red and blue buttons that control wing shift if the filter is being used in a public environment or where assurances that the filter will not be accidentally set off band are required To toggle the button lockout setting depress both the red and blue buttons while plugging in the power cord After the display appears release both buttons Repeat the procedure to undo the lockout 35 7 DayStar Quantum Control Ioj x File Controls Display Settings Help Visible Spectrum Solar Filter Transmission Spectrum On the label of the filter is a temperature rating The Quantum will operate as designed between approximately 0 F and the labeled temperature Above the labeled t
54. uses a temperature regulated oven to effect tuning and control of wavelength Peak transmission wavelength will also change with the angle of incidence of light encountering the Fabry P rot etalon due to the longer path length when light traverses the mica at an angle A tilt of the Fabry Perot etalon crystal causes a shift towards the blue causing a decrease in the CWL transmitted regardless of the direction of the tilt In addition to blue wing CWL shift the FWHM of the transmitted light will widen with tilt As demonstrated in the following chart of measured CWL shift versus angle of incidence angles must be kept under one degree for the filter to perform to specification CWL Shift Angstroms 0 1 2 3 4 5 6 7 8 9 Angle of Incidence Degrees Figure 9 Center wavelength shift with angle of incidence This tilt dependence results in a cumulative FWHM widening in optical paths with a fast focal length light cone The center of the light cone has zero angle of incidence and therefore zero shift while light from the extremity of the light cone will pass through at an angle and be shifted lower altogether resulting in a wider effective bandpass Therefore it is necessary to configure the focal ratio of the optical path to achieve slow or long focal ratios Simple geometry shows that to keep the angle of incidence below one degree the 1 focal ratio of the telescope system must be longer than 2 tan 1 or F 28 for bandpass appl
55. viding immunity from ambient temperature fluctuations Preliminary specifications subject to change Wing shift range 1 0 A Tilt range 0 to 2 8 degrees Stop to stop slew time 1 5 seconds CWL adjustment precision 0 1 Clear aperture zero tilt 1 0 wing shift 32mm 1 25 Clear aperture full tilt 1 0 A wing shift 30mm 1 18 Mechanical drawings All dimensions in millimeters drawings not to scale Shown with removable Q3RFCTM plate Subject to change until production release Figure 32 Quantum Turbo conceptual drawing 47 48 101 60 Figure 33 Quantum Turbo dimensions
Download Pdf Manuals
Related Search
Related Contents
Case Logic Optical mouse Smeg PLA8743X Instruction Manual Argoclima Rock MINISTÉRIO DO TRABALHO E EMPREGO GABINETE DO 電子レンジ火災にかかわる注意喚(PDF形式243キロバイト) MANUEL D`UTILISATION DU VAPORISATEUR View/Open ParCar design allows for safety and service 平成22年度「中東講座」開催 Copyright © All rights reserved.
Failed to retrieve file