Home
User Manual for ioLogik E2262
Contents
1. OG Change Password 3 Load Factory Default CJ Save Restart Network Connection Agen Configurations SNMP O Enable O Disable Read Community Name public Write Community Name public Contact Location On the Network Connection page you can view the TCP connections from other hosts This can assist you in the management of your devices 3 Overview Basic Settings HO Network Settings I 1 0 Settings 3 System Management 3 Accessible IP Settings C2 SNMP Agent 3 Firmware Update GO Import System Config CJ Export System Config LCM 2 Change Password 0 Load Factory Default Save Restart Firmware Update Network Connection Total connection s 1 Host Address 192 168 127 3 Connection Type Web HTTP On the Firmware Update page you can load new or updated firmware onto the ioLogik Overview I Basic Settings 9 Network Settings I VO Settings 3 System Management CJ Accessible IP Settings CO SNMP Agent Network Connection 3 Import System Config Export System Config CJ LCM 3 Change Password Load Factory Default 1 Save Restart Firmware Update Choose a new firmware file path Warning 1 The firmware update process may take about few minutes 2 Attention Once you press the Update button this progress cannot be reversed 3 Disconnecting power or network cable would lead to firmware corru
2. Utilities loAdmin Main Screen Main Screen Overview This is 10Admin s main screen The main window defaults to the I O Configuration tab which displays a figure of the ioLogik E2262 and the status of every I O channel below it The other tabs in the main window take you to server and network settings and further functions are available when you log on as an administrator Note that configuration options are not available until you log on as an administrator M MOFA m dmin Pia ds i IK Type 1FLJ 00 10123456 709MBC E Type WaterT a TCk03 TCk04 CIC Temp 05 TCk06 TCk07 11Ck08 TCk09 CEO Quick link Navigation panel Main window Sync rate status Status bar K Type K Type E Type K Type K Type K Type K Type 3 4 00071 NU 2000712500 200 073000 2000712500 2000712500 2000712800 2000712500 2000712500 D0 00 100 01 100402 1D0 03 115200 None 8 1 00 00 12 am 11 33 07 ioLogik E2262 User s Manual Utilities Wiring Guide 10Admin provides a wiring guide to the 10Logik E2262 You can access the wiring guide by right clicking the figure of the 10Logik E2262 in the I O Configuration tab Select Wiring Guide in the submenu to open a help file showing the wiring information and electrical characteristics of the ioLogik E2262 1 E2262 Active Ethernet VO 8 Thermocouple Inputs and 4 Digital Outputs al System Overview Ethernet pin assignment Mi
3. J 0 to 750 C 0 to 7500 K 200 to 1250 C 2000 to 12500 T 200 to 350 C 2000 to 3500 E 200 to 900 C 2000 to 9000 R 50 to 1600 C 500 to 16000 S 50 to 1760 C 500 to 17600 B 600 to 1700 C 6000 to 17000 N 200 to 1300 C 2000 to 13000 2 3 uV 78 126 to 78 126 mV 781260 to 781260 1 15 uV 39 062 to 39 062 mV 390620 to 390620 0 5 uV 19 532 to 19 532 mV 195320 to 195320 8 Average Difference 4 sink type 24 VDC nominal 30 VDC max Max 200 mA per channel 2 KVrms 3 KVDC 1 4 ioLogik E2262 User s Manual Introduction Protection Power Requirements Power Input Power Consumption Field Power Mechanical Specifications Wiring Environmental Operating Temperature Storage Temperature Shock Freefall Vibration MTBF Agency Approvals EMC Safety Warranty Period Over temperature shutdown 170 C Over current limit 750 mA channel typical 24 VDC nominal 12 to 48 VDC max 175 mA 24 VDC typical 4 6 W with LCM max 24 VDC nominal up to 48 VDC VO cable max 14 AWG 10 to 60 C 14 to 140 F 5 to 95 RH 40 to 85 C 4 to 185 F 5 to 95 RH TEC60068 2 27 TEC60068 2 32 TEC60068 2 6 gt 200 000 hrs 25 C FCC Part 15 CISPR EN55022 Class A CE IEC61000 4 2 ESD Level 2 3 CE IEC61000 4 3 RS Level 2 CE IEC61000 4 4 EFT Level 2 CE IEC61000 4 5 Surge Level 3 CE IEC61000 4 6 CS Level 2 CE IEC61000 4 8 PM Level 1 CE IEC61000 4 11 Dip CE EN61000
4. gt Connecting the Power Grounding the ioLogik E2262 Connecting to the Network Setting the RS 485 Baudrate Adding More I O Channels O Software Installation 2 Initial Setup ioLogik E2262 User s Manual Initial Setup Hardware Installation Connecting the Power Connect the 12 to 48 VDC power line to the 10Logik E2262 s terminal block TB1 If power is properly supplied the Power LED will glow a solid red color until the system 1s ready ATTENTION Disconnect the power before installing and wiring Disconnect the power cord before installing and or wiring your ioLogik E2262 Do not exceed the maximum current for the wiring Determine the maximum possible current for each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current exceeds the maximum rating the wiring could overheat causing serious damage to your equipment Grounding the ioLogik E2262 There are two grounding points on the ioLogik E2262 the wall mounting point and the DIN rail mounting plate Note that both grounding points are actually connected to the same conducting pathway Connecting to the Network 1 Connect the ioLogik E2262 to the host PC with an Ethernet cable For initial setup of the 10Logik E2262 it is recommended that the ioLogik E2262 be configured using a direct connection to a host computer rather than remotely over the network 2 Note the ioLogik s defau
5. 256 255 255255 255 255 255 255 DNS 2 255 255 255 255 Web Access Settings IP Settings You can assign a static or dynamic IP address to the ioLogik E2262 as well as the subnet mask and gateway address The Accessible IP screen can be used to control network access to the 10Logik E2262 and attached sensors The ioLogik will reject all requests that do not originate from sources listed in the accessible IP list Leave this list blank in order to allow requests from any IP address Modbus TCP Alive Check Timeout The Modbus TCP Alive Check Timeout is designed to avoid TCP connection failure When the host is down the ioLogik E2262 will continue to wait for a response from the host This will cause the TCP port to be indefinitely occupied by the host When the Modbus TCP idle connection timeout interval is enabled the ioLogik E2262 will close the TCP connection automatically if there is no TCP activity for the specified time Please note that Modbus TCP connections will be blocked when setting up Accessible IP 3 15 ioLogik E2262 User s Manual Utilities DNS Settings Use this field to specify up the IP addresses of up to 2 DNS servers These two DNS servers can be used to automatically find available e mail addresses when using Click amp Go Logic Serial Settings You can view the reserved RS 485 communication parameters here and you can set the timeout value for breaks in RS 485 communication Note that the other serial communicati
6. Fahrenheit 0 0001 mV 30033 0x0020 1 word CHO TC Minimum Value Hi Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30034 0x0021 1 word CHO TC Minimum Value Lo Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30035 0x0022 CHI TC Minimum Value Hi Word B 3 ioLogik E2262 User s Manual Modbus Mappings 30036 0x0023 CHI TC Minimum Value Lo Word 30037 0x0024 CH2 TC Minimum Value Hi Word 30038 0x0025 CH2 TC Minimum Value Lo Word 30049 0x0030 1 word Virtual CH8 TC Minimum Value Hi Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30050 0x0031 1 word Virtual CH TC Minimum Value Lo Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30065 0x0040 1 word CHO TC Maximum Value Hi Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30066 0x0041 1 word CHO TC Maximum Value Lo Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV B Ja ioLogik E2262 User s Manual Modbus Mappings 30078 0x004D CH6 TC Maximum Value Lo Word 30079 0x004E CH7 TC Maximum Value Hi Word 30080 0x004F CH7 TC Maximum Value Lo Word 0x0050 1 word Virtual CH8 TC Maximum Value Hi Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 0x0051 Virtual CH8 TC Maximum Value Lo Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 4xxxx Read Write Registers Functions 3 6 16
7. 3 IP Address 4 Unit ID Several operations are possible from the System menu Auto Scan Active Ethernet I O Server will search for ioLogiks on the network When connecting for the first time or recovering from a network disconnection you can use this command to find I O servers that are on the network Network Interface allows you to select a network to use if the PC has multiple network adapters installed I O Status Refresh Rate is used to adjust how often the I O server is polled for device status The current rate is displayed on the status bar at the bottom of the window Note that higher sync rates result in higher loads on the network TCP Socket Timeout Interval allows you to select the preferred timeout value for TCP socket communication COM Port Setting is used to set the parameters for Modbus communciation such as baudrate data bits and timeout interval For most applications this will involve connecting to 10Logik R Series devices Active Message Listen Port specifies the port number to use for Active Ethernet I O messages If your network uses a firewall you can coordinate this setting with your firewall settings to ensure that active messages get through Reset NA4010 Network Adapter IP is used to re assign an IP address to the NA 4010 network adapter for 10Logik 4000 systems 3 6 ioLogik E2262 User s Manual Utilities E MOXA ioAdmin File System Sort Help Q g w 2 HA Auto Scan Active Ethernet 1
8. 4 Alias Name Alias name of channel DO Alias name of logic 0 OFF Alias name of logic 1 OP Close Mate Pulse width unit 5ms range 1429496729095 Warning Be sure to Save Restart your setting You can use the Power On Setting field to specify the channel s status when the ioLogik E2262 is powered on and the Safe Status Setting field to specify the channel s status 1f the network 1s disconnected Note that Safe Status 1s controlled by the Host Connection Watchdog which 1s disabled by default If the Host Connection Watchdog 1s disabled the channels Safe Status settings will have no effect 4 6 ioLogik E2262 User s Manual Using the Web Console System Management Accessible IP Settings On the Accessible IP Settings page you can control network access to the 10Logik E2262 When the accessible IP list is enabled a host s IP address must be listed in order to have access to the ioLogik E2262 Accessible IP Settings LI Overview U Basic Settings O Enable the accessible IP list Disable will not allow all IP s connection request di lal Network Settings No Active IP Address Netmask 1 0 Settings 23 System Management CJ SNMP Agent 3 Network Connection CJ Firmware Update CJ Import System Config Export System Config El LCM OG Change Password 3 Load Factory Default A Save Restart 0 0 JO 0 BU N kb a3 N a PA CA 3 353 m o You can add a specific address or range of address
9. 6 2 CE EN61000 6 4 UL 508 2 years 1 5 ioLogik E2262 User s Manual Introduction Physical Dimensions With LCD Module 45 63 5 95 l Unit mm ET ATE pk 000000000000000000000000 099 o Frem i 3 115 21 8 44 5 35 1 6 89 Mil FB di kel pe 1 J 79 1 6 ioLogik E2262 User s Manual Introduction Without LCD Module Unit mm 5 95 24 44 9 51 000000 ETIHTTTITTTTITTTTTITTTTTTTITTIN al 46 51 6 a 115 121 8 Hardware Reference Panel Guide TB1 SLN g REM Ba Bu EG OO ES MOA 00060000006000060000000006006 TB2 NOTE The reset button restarts the server and resets all settings to factory defaults Use a pointed object such as a straightened paper clip to hold the reset button down for 15 sec The RDY LED will turn red as you are holding the reset button down The factory defaults will be loaded once the RDY LED turns green again At this point you can release the reset button ioLogik E2262 User s Manual Introduction LED Indicators Ethernet Valid 10 Mbps Ethernet connection Ethernet Valid 100 Mbps Ethernet connection flashing Transmitting or receiving data System med Powers on O off Powerisoff o pred Systememor O Thermocouple ae ene Digital Output DO x4 channels Bann This chapter describes how to install the ioLogik E2262 The following topics are covered LJ Hardware Installation gt YYY
10. Menu The Server context menu is accessed by right clicking on the server model name in the navigation panel se MOEA Admin File System Sort Help ed IF Host 192 168 127 4 HER ioLogik Fra 192 168 127 254 Komert Disconnect Delete NO Sener Add Serial DO Server Restart viten Reset to Default Import System Config E Export System Config 3 18 ioLogik E2262 User s Manual Utilities Connect Select this command to have 10Admin attempt a re connection over the network to the selected ioLogik server Disconnect Select this command to have ioAdmin drop the network connection with the selected ioLogik server Delete I O Server Select this command to have 10Admin remove the selected serial I O Add Serial VO Server Select this command to manually add a serial I O server by using its Unit ID Restart System Select this command to restart the selected ioLogik server You will need to log in as an administrator to use this function Reset to Default Select this command to reset all settings for the selected ioLogik server including console password and IP address to factory default values You will need to log in as an administrator to use this function Export System Config Select this command to export the configuration of the selected ioLogik server to a text file You will need to log in as an administrator to use this function It is strongly recommen
11. Safe Status Settings DO status Pulse mode parameter OFF M Ja Apply to all channels Alias Name Channel Name po Logic 0 oFF Logic 1 on Jf OK In DO mode the specification is as follows 3 12 ioLogik E2262 User s Manual Utilities Type LogicO OFF Logic 1 ON In Pulse Output mode the selected digital output channel will generate a square wave as specified in the pulse mode parameters The low and high level widths are entered in multiples of 5 ms with a maximum setting of 4 294 967 295 or 248 days 13 hours 13 minutes and 56 seconds To set the low level width for 500 ms you would enter 100 because 100 x 5 ms 500 ms If the low width value is 500 and the high width value is 500 the pulse output would be a square wave with a 5 second pulse cycle If continuous pulse output is desired enter O for the number of pulses otherwise enter the desired number of pulses between 1 and 4 294 967 295 Power On Settings Use this field to set the initial behavior of the DO channel when the ioLogik E2262 is powered on You can configure whether or not the DO is set to OFF or ON at power up For DO channels in Output Pulse mode you can configure whether or not the pulse output commences at power up Safe Status Settings Use this field to specify how the DO channel behaves when the network connection is lost When the network connection is lost for the amount of time specif
12. lt RW gt 0 4294967295 lt RW gt 0 4294967295 40009 0x0008 1 word CH0 DO Pulse Output Low Signal Width Hi Word lt RW gt 0 4294967295 40010 0x0009 1 word CHO DO Pulse Output Low Signal Width Lo Word lt RW gt 0 4294967295 Word 40012 0x000B 1 word CHI DO Pulse Output Low Signal Width Lo Word 40013 0x000C CH2 DO Pulse Output Low Signal Width Hi Word ioLogik E2262 User s Manual Modbus Mappings Word Word Word 40017 0x0010 1 word CHO DO Pulse Output High Signal Width Hi Word lt RW gt 0 4294967295 Word Word Word Word CH0 DO Pulse Output High Signal Width Lo Word lt RW gt 0 4294967295 40023 0x0016 1 word CH3 DO Pulse Output High Signal Width Hi Word 40024 0x0017 1 word CH3 DO Pulse Output High Signal Width Lo Word 40025 0x0018 1 word CH0 DO Operation Mode lt RW gt 0 DO Mode 1 Pulse Output Mode word 40027 Ox001A word CH2 DO Operation Mode 40028 0x001B word CH3 DO Operation Mode 40029 0x001C 1 word CH0 TC Engineering Unit word word word word i 0 Celsius 1 Fahrenheit 2 millivolt 40034 0x002 I word CH5 TC Engineering Unit 40035 0x0022 word CH6 TC Engineering Unit word CH7 TC Engineering Unit 40036 0x0023 Virtual CH8 TC Engineering Unit 0 Celsius 1 Fahrenheit 2 millivolt 0 J Type O ioLogik E2262 User s Manual Modbus Mappings 1 K Type 2 T Type 3 E Type 4 R Type 5 S Type 6 B Type 7 N Type S Voltage 78 126mV 9 Voltage 39 062m
13. take effect This command can be used to restore a configuration after loading the factory defaults or to duplicate a configuration to multiple 10Logiks 3 20 ioLogik E2262 User s Manual Utilities Using TFTP to Import Export Configuration AN TFTP Trivial File Transfer Protocol provides basic FTP functionality in a very simple protocol Due to TFTP s simplicity it can be implemented using a very small amount of memory an important consideration when it was first developed The ioLogik E2262 supports the use of TFTP to import or export configuration files The following is an example using Windows TFTP and an ioLogik E2262 with an IP address of 192 168 127 254 1 Enter TFTP 192 168 127 254 GET 1k2262 txt to get the 10Logik s configuration file 2 Enter TFTP 192 168 127 254 PUT 1k2262 txt to load a configuration file onto the ioLogik You must use 1k2262 txt as the destination filename when copying a configuration file to the ioLogik E2262 Otherwise you will receive an error message as shown below Error on server ocma srv 58 tcp PCMa il Server snmp 51 udp SNMP snmpt rap 32 udp snmp trap SNMP trap print srv 707 IPX over IP tl ightweight Directory MCom MCc 443 udp MCo You can use TFTP in a batch file to transfer configuration files for different units For example you might have two configuration files that need to be copied to two different servers 1k2262_1 txt fo
14. up to three I O channels within each trap W SNMP Trap a M Active Message Active Active Message 00000 mi Ema ze SNMP Trap Settings ioLogik E2262 User s Manual Click 4Go Logic E mail Select E mail to send a user defined email to the specified addresses Click the memo icon to enter the desired message and the intended recipients Dynamic fields such as time date IP address and I O status can be inserted in your message by clicking on the Keyword Lookup button If you already set the Alias Name on I O Configuration page the channel will be replaced here To select a recipient you must first add the recipient s e mail address to the Available receivers list You can then use the finger icons to move e mail addresses to and from the Receivers list To edit an e mail address click the memo icon Note that the Available receivers list will already contain a list of names if you provided the DNS server information in the Network Settings tab Enter your own e mail address in the From Address field Under Mail Server Settings you must configure the IP address of the SMTP server with your username and password Since the ioLogik E2262 supports DNS you can enter the domain name of the SMTP server ge Mail Settings Hail Content Settings Mail Subject Mail Content ce Keyword Lookup Hail Address Settings Mame Mail Address EN Addl Recipient Database Global Settings Recipient List e Mail Ad
15. 0 Server i Network Interface 1 0 Status Refresh Rate TCP Socket Timeout Interval laag COM Port Setting Active Message Listen Port Reset NA4010 Network Adapter IP Enable Host Lonne Or Sort The Sort menu allows the server list in the navigation panel to be sorted by connection type and location Sot Help pe a w Sl By 1 0 Server Connection By 1 0 Server Type W By 1 0 Server Location Help In the Help menu you can view wiring guides and information about ioAdmin Help a 18 ing Wiring Guide for 10Logik2000 Wiring Guide for 1oLogik4000 About Quick Links Quick links are provided to search for I O servers on the network and sort the server list 212 pol r Search network for I O servers Sort by connection Sort by I O server type jud Sort by location 3 7 ioLogik E2262 User s Manual Utilities Main Window O Configuration Tab General The I O Configuration tab shows the status of every I O channel This is the default tab when you first open ioAdmin 8550000600600000000000006 IE Type 1FLF 00 KType 2000 1500 Deg C Dat 012345G70MMBC E Type A fra Dep E IE TmpeWatela E Type 5 Deg E mepo ET i Es Deg C TC 04 Type a 251 Deg C CIC Temp 05 E Type OOS Deg C TCk06 Kle 200 012 Deg C ree Rte Des Cos AVG gt 0 un Deg CLOS AMG Deg C EET AMG oo Deg EET AMG C Deg E TCk12 gk 0 Deg C ITCH3 ANG 00 Deg C Server Inf
16. 00 12500 200012500 2000712500 2000712500 i Belaae BA pl i You can now use ioAdmin to set up or configure your ioLogik E2262 3 Utilities This chapter goes over the functions available in ioAdmin the ioLogik E2262 s main configuration and management utility The following topics are covered E E E D D O Introduction to ioAdmin Features of ioAdmin ioAdmin Main Screen gt Main Screen Overview gt Wiring Guide Menu Items gt File gt System gt Sort gt Help gt Quick Links Main Window I O Configuration Tab General gt Server Info Tab gt Server Settings Tab General gt Message Monitor Tab ioAdmin Administrator Functions gt I O Configuration Tab Administrator Server Settings Tab Administrator Network Tab Firmware Update Tab Watchdog Tab Click amp Go Logic Tab Server Context Menu V VV VV WV Using TFTP to Import Export Configuration Using ioEventLog ioLogik E2262 User s Manual Utilities Introduction to ioAdmin The ioLogik VO server can be managed and configured over the Ethernet by ioAdmin a Windows utility provided with your ioLogik E2262 10Admin s graphical user interface gives you easy access to all status information and settings The ioLogik E2262 also supports configuration by web console and by optional LCM but full configuration and management is only available through 10Admin A new feature in ioAdmin automatica
17. 22 52 26 Modify LCM System Elapsed Time 1 4 49 Time zone 24 hour GMT Greenwich Mean Time Dublin Edinburgh Lisbon London vi Change Password Time server Load Factory Default Web console O Enable O Disable Save Restart 4 2 ioLogik E2262 User s Manual Network Settings General Settings Using the Web Console On the General Settings page you can assign a server name and location to assist you in differentiating between different I O servers You can also enable the Host Communication Watchdog and define the timeout value CI Overview Basic Settings 23 Network Settings LJ General Settings GI Ethernet Configurations CJ RS 485 Settings I O Settings E ar BROOD System Management LEM Change Password Load Factory Default Save Restart en A ANA y 1 0 Server Settings Server Name Server Location DNS Server 1 DNS Server 2 O Enable communication watchdog Location 0 SEC When enabled the Host Connection Watchdog activates Safe Status settings for DO channels when the ioLogik E2262 loses its network connection for the specified amount of time By default the Watchdog is disabled You can use ioAdmin to configure each DO channel s Safe Status setting To enable the Watchdog make sure that Enable connection watchdog is checked set the timeout value and restart the server Ethernet Configuration On the Ethernet Configuration page you can
18. 4 AE MD 5 5 SNMP Dia RR een ME EE 5 6 Bier ie EE EA ER a GNG ae KE EG 5 7 Working with ClICk amp G0 Kulesels vs 5 8 Ans the RUN 5 8 Ruleset Man adement Bar aan u a ae 5 8 Re ol 5 8 Liquid Crystal Display Module LCM eannnrrnnnnnvrrnnnnnvernnnnnvvennnnnveennnnnnr A 1 Appendix B Appendix C Appendix D Appendix E Appendix F MOADUS MaDpDINdS Lal B 1 Oxxxx Read Write Coils Functions 1 5 15 esse ees sees ee ee ee ee ee ee ee Ge ee B 1 Sxxxx Read Only Reeisters Function Dissen ah B 3 4xxxx Read Write Registers Functions 3 6 16 esse EE Ee ee ee ee RR ee ee ee B 5 5SXXXX Write Registers FUNCLION Saastad RE eke AGA ka B 9 Used Network Port Numbers ss aa Se ee RE vaen bee SEE C 1 SNMP MIB lisina da D 1 RFC 1215 MIB II Supported SNMP VYariables u AG ade D 1 Factory Default Settings a GN Ge Ge N AGUA E 1 Pinouts and Cable Wiring iss ee EE RR EE ER RR EE EE RR REG EER REG ERK REGEER RR RR ee RR F 1 Ethernet Port 18 1819 101 ed EE A ol F 1 Senal Port PINONG AGO E uni F 1 Thermocouple Input NS RT ed a F AA F 1 PAA APA F 2 DISTALOMIIPUE AR EO EIEN F 2 O F 2 Pl F 2 terminal BOK Posse F 3 1 Introduction The ioLogik E2262 1s a stand alone Active Ethernet I O server It connects thermocouple sensors and digital output on off switches for automation applications over Ethernet and IP based networks The following topics are covered in this chapter LI Overview gt Traditional Remote I O gt
19. Active Ethernet I O gt Click amp Go gt Optional Liquid Crystal Display Module LCM Product Features Packing List Product Specifications COOL Physical Dimensions gt With LCD Module gt Without LCD Module 0 Hardware Reference gt Panel Guide gt LED Indicators ioLogik E2262 User s Manual Introduction Overview shown with and without optional LCM The ioLogik E2262 is part of the E2000 line of ioLogik Active Ethernet I O servers which are designed for intelligent pro active status reporting of attached thermocouples over a network It includes 2 MB of Flash ROM and 8 MB of SDRAM An optional hot pluggable Liquid Crystal Display Module LCM can be used to view and configure device settings Traditional Remote VO Ethernet remote I O solutions have been on the market for a long time Traditional solutions are passive in the sense that I O servers wait passively to be polled by a host computer The response time in this type of setup however tends to be on the order of seconds The passive remote I O structure is simply inadequate for data acquisition and control systems that require a response time on the order of hundredths of seconds Active Ethernet VO Moxa s Active Ethernet I O line was developed specifically to address the limitations of the traditional passive approach Rather than having the host computer poll the I O device server over the network for the status of each I O device th
20. G Do not interrupt the firmware update process An interruption in the process could result in your device becoming unrecoverable After the firmware 1s updated the 10Logik will restart and you will have to log in again to access administrator functions The firmware on any attached I O expansion module such as an 10Logik R2000 server must be updated over the RS 485 bus Firmware on cascaded modules cannot be updated over Ethernet 3 16 ioLogik E2262 User s Manual Utilities Watchdog Tab The Watchdog tab 1s where you configure the Host Connection Watchdog which 1s used with the Safe Status settings to define each DO channel s response to a lost network connection When the Host Connection Watchdog is enabled the 10Logik E2262 will respond to network disconnections that exceed the specified amount of time The ioLogik will respond by resetting DO channels to their Safe Status settings By default the Watchdog is disabled To enable the Watchdog make sure Enable Host Connection Watchdog is checked set the Timeout value then click the Update button J 140 Configuration db Server Info EN Server Settings E Network gi Firmware Update 8 watchdog Ki Click amp Go Logic Message Monitor Host Connection Monitor Enable Host Connection Watchdog Timeout value SEC If the Watchdog is enabled and the network connection has been lost you will need to return to the Watchdog Tab in order to resume normal opera
21. Hes 000600 Bm AAA ENE ENE ar MOXA R5 485 Communication Settings 0 115200ps NB1 1 57600bps N81 2 38400bps NB1 iologik 3 19200bps NG1 375 E mapa ei 4 9600bps N81 G TUU UUE I SENET IE 5 4800bps N81 bobobobobabobobs igan 6 2400bps N81 ua rr 7 1200bps N81 BRSESSSEREESE a sis DO Wiring Example TC Input 1 2 Wire Thermocouple Input Menu Items File From the File menu you can export the list of I O servers that are currently displayed in the navigation panel You also can import a list of I O servers into 10Admin Import 1 0 Server List Export 1 0 Server List CH sun n o 1818 alv Exit E2260 lt 192 168 127 253 gt 1 0 Configuration W Ser P Location 241 E2260 lt amp DL 2168 40 KM DAAN 2107 100 127 64 F When importing a server list you will be prompted to select which servers on the list need to be imported 3 5 ioLogik E2262 User s Manual Utilities System Select 1 0 Server to Import Select Server List File to Import D ServerList sit B Y SelectAll 0 unSelect All vlE 2260 Test2 E2260 132 169 127 294 Y 3E2260 Test E2210 192 168 127 220 v 4R2110 Test R2110 192 168 127 254 2 Jf OK X Cancel The file will have a SLT extension and can be opened as a text file The server list will provide the following information for server 1 Server Name 2 Module Type
22. N 3 5 SO EE NE EN EE EN Ee 3 6 AE 3 7 ld EE OE EA OR EE EE 3 7 a AA Ge 3 7 Man Won NE 3 8 LO Con tumuon Tab GENE a ei 3 8 AA AA 3 8 Server settines Tab General nun 3 9 Message Monitor Ta ee 3 9 10Ad n n Administrator Funetions a alu Mina nn 3 10 VO Configuration Tab Administrator aan au aan da 3 10 Server Settings Tab Administrator aaa a ukki laual AA 3 14 Netso AA 3 15 abe Update ANO 3 16 ees leid ke AR neuen 3 17 CEEL Go ooie T hv 3 17 Chapter 4 Chapter 5 Appendix A Server Context Menu Ga Aa aa 3 18 Using TFTP to Import Export Configuration sees sesse sesse EE ee ee ee ee ee ee RR ee ee ee 3 21 sing ol ENE nese 3 22 Installino 9 88 75 110150 dd dia 3 22 BASIC PUNO aaa AE iia 3 22 Cope ae 3 23 Checking Connect PE 3 24 IA Da 3 24 BG die 0 esse ies n Oe ee Ai ie Ee Aa oo ee RS ie sk ge oe ie IE 3 24 Using the Web Console NANANA ANAN 4 1 Introduction to the Web Console 4 2 BL DN 4 2 Network SELINA JE 4 3 General CLM SE ea EE oe de een A 3 Ethernet Corsa ee u Ge eg A 3 RS SN 4 4 OSEN 4 4 TE MN 4 4 OM 4 6 System MENN 4 7 Accessible PS 4 7 PN 4 8 NAV KE ME 4 8 made se 4 8 Import System CONN SAGE 4 9 Export System CON ss er 4 9 EN 4 9 Che Pus 4 10 Load Factory De valen 4 10 A E E T 4 10 GIEK amp GO EOGIG varene 5 1 NN 5 2 SS A O 5 2 CUELGO LOSE Basis seen 5 2 Work ng WAR GS 5520 en ee 5 3 De tine EOSIE Rule AA 5 4 Summary of TE THEN Para meter susi a ne tum na 5 4 FrP 5 4 THEN AN nee I 5
23. Pulse Hi Width for Pulse Output Pulses Password Module Name Module Location SNMP Community Contact Location Click Go The ioLogik E2262 is configured with the following factory defaults 192 168 127 254 255 255 255 0 None Disable 60 secs K type Enable Celsius DO Off Off x3 ms x3 ms 0 continuous NONE NONE NONE Enable Public NONE NONE NONE F Pinouts and Cable Wiring Ethernet Port Pinouts Serial Port Pinouts E2262 RS 485 Network Adapter Pin Assignment V V FG D D 5G Thermocouple Input Wiring structure Pinouts and Cable Wiring s 3 23 8 3 3 83 3 3 a a aia ad 3163 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 1 ioLogik E2262 User s Manual 2 wire Digital Output Structure Output Channel DO PWR is for powering up the field Power LED F 2 ioLogik E2262 User s Manual Pinouts and Cable Wiring Terminal Block Pin Assignments 000000 TB1 ILLALLA V V FG Dr D SG bss S5azagE HH HK H HK NN HK HK H MOMO NUM TB2 TB1 E a a EE A alas 1 t mE BEN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TB2 TCO TCO TC1 TCI TC2 TC TC3 TC3 TC4 TC4 TC5 TC5 TC6 TC6 TC7 me DO GND DO GND DO 0 DO 1 DO 2 DO 3 DO PWR F 3
24. Sensor Type Range Status Value Min Max 13 Network Settings K Typo 1FL 00 K TYPE 700 v 125007 enabled 43 5 0 8 558 3 T NO Setongs 10 01 K TYPE 200 1250 Enabled a KJ Te Channels E Type WaterTank 02 E TYPE 200 9007 Enabled 27 6 15 5 107 4 CJ Do Channels Up to 16 chars 03 K TYPE 200 125077 Enabled NGA System Management TC 04 K TYPE 200 1250 Fnahled 29 7 28 9 612 2 dices CIC Temp 05 K TYPE 700 1250 enabled 29 1 2 1 560 8 LEM TC 06 K TYPE 200 v 1250 Enabled ai ES 29 Change Password TC 07 KTYPE 200 125077 Enabled Gd Load Factory Detauk Virtual Channel Mode Unit Value Min Max D Save Restart rc na Avoraqe e 0 0 0 0 0 0 IC 09 Average Te 0 0 0 0 0 0 TC 10 I Average T 0 0 0 0 0 0 TC 11 Average o 0 0 0 0 0 0 TC 17 Average 0 0 0 0 n n TC 13 Average 0 0 0 0 0 0 IC 14 Average 5 dd 0 0 0 0 uu LTC 15 Difference C 39 1 38 3 560 0 NOTE channel Is lacked by logic Gear Max amp Min Refresh 4 4 ioLogik E2262 User s Manual Using the Web Console You can click on each channel to enable or disable it or to configure the TC input mode When a channel has been disabled the sample rate of the remaining channels will be increased automatically SA hol 150 177 254 TO Camal ietin Maimai kecut Eslora TG Channel 0 Settings M Channel 15 Settings Enable Sensor Type Range Unit Mode Selected Channel Unit FEE MEN feos Allas name of channel Alia
25. V 10 Voltage 19 532mV CH3 TC Sensor Type CH4 TC Sensor Type CH5 TC Sensor Type 40053 0x0034 1 word CHS TC Sensor Type 20 AVG 21 DIF 40061 0x003C 1 word CH0 TC Reset Minimum Value lt R gt Always 0 lt W gt 1 Reset 0 return illegal data value 40077 0x004C 1 word CHO TC Reset Maximum Value lt R gt Always 0 lt W gt 1 Reset 0 return illegal data value 7 v ioLogik E2262 User s Manual Modbus Mappings 40093 0x005C 1 word CHO DO Status lt RW gt 0 OFF 1 ON lt RW gt 0 OFF 1 ON 40099 0x0062 CH2 DO Status 40100 0x0063 CH3 DO Status lt RW gt 0 OFF 1 ON lt RW gt 0 Stop 1 Start 40107 0x006A CH2 DO Pulse Output Status 40108 0x006B CH3 DO Pulse Output Status lt RW gt 0 Stop 1 Start 40112 0x006F CH3 DO Pulse Output Status 40113 0x0070 1 word CHO DO Safe Pulse Output Status lt RW gt 0 Stop 1 Start 40114 0x0071 CHI DO Pulse Output Status 40115 0x0072 CH2 DO Pulse Output Status 40116 0x0073 CH3 DO Pulse Output Status 40117 0x0074 1 word CHO TC Enable lt RW gt 0 Disable 1 Enable 40118 0x0075 CHI TC Enable 40119 0x0076 CH2 TC Enable 40120 0x0077 CH3 TC Enable pa Oo ioLogik E2262 User s Manual Modbus Mappings 40121 0x0078 CH4 TC Enable 40122 0x0079 CH5 TC Enable 40123 0x007A CH6 TC Enable 40124 0x007B CH7 TC Enable 5xxxx Write Registers Function 8 Sub function Data Field Request Data Field Response 0x0001 OxFFOO Echo Request Data Reboot 0x0001 O
26. XSSAA Echo Request Data Reset with Factory default C Used Network Port Numbers E2262 Network Port Usage 68 UDP BOOTPC 68 UDP 69 UDP _ Export Import File gt 80 TCP WebServer SNMP D SNMP MIB II RFC1213 MIB II Supported SNMP Variables The following SNMP variables are built into the ioLogik firmware and are compliant with RFC1213 MIB II ioLogik E2262 User s Manual Pinouts and Cable Wiring fnsanReasmanSizelempOtAdrsks a KE EE EE Er Ba Ka gesag iones Ba forme enma a UU fipneitometiaNeaddres Jetta _ IpRoutingDiscards D 2 ioLogik E2262 User s Manual Pinouts and Cable Wiring Peters mois A TA Address Translation MIB comas poe O COO oon pampes UU fepcomnkemAddres _ nmlnseiReqies ocio ET its huge Ponts lmpOulosbis 0 moscas CU radiales yy vo ros oe SR A rms A roces ras TO TT D 3 ioLogik E2262 User s Manual Pinouts and Cable Wiring Private MIB File and SNMP Variables Moxa also provides an SNMP to I O MIB file that can help you monitor I O status with SNMP software You can find the MIB file on the Document and Software CD DO00 Range aaa aay TOM E Factory Default Settings Default IP Address Default Netmask Default Gateway Communication Watchdog Watchdog Timeout TC Sensor Type TC Enable TC Unit Type DO Mode DO Safe Status Power On Status Low Width for
27. annels can be added using the ioLogik R2110 and analog I O channels can be added using the ioLogik R2140 For additional details please refer to the ioLogik R2110 or R2140 user s manual mm Ug EN GE ua male re RET E IJ Put gem ms sm gen HE EE EE HE vEE MS OM Aa N 3 PE pm big gg Pi a LET 1 Mr ar NE Id ER RE Her i I ae sina An Ae i Wa a ae a ser Software Installation 10Admin is a Windows utility provided for the configuration and management of the ioLogik E2262 and attached I O devices It can be used from anywhere on the network to monitor and configure the ioLogik E2262 You can also configure some of the settings through the web console or optional LCM 1 Installation from CD Insert the Document and Software CD into the host computer In the root directory of the CD locate and run SETUP EXE The installation program will guide you through the installation process and install the ioAdmin utility You can also install the MXIO DLL library or 10EventLog separately 2 Open ioAdmin After installation is finished run ioAdmin from Start gt Program Files gt Moxa gt IO Server gt Utility gt ioAdmin 3 Search the network for the server When ioAdmin is started a pop up window will appear to help you search for these I O devices Or you can search for a specific model On the menu bar select System gt Auto Scan Active Ethernet I O Server In the dialog window that appears click Start Search to begin sea
28. ator again in 10Admin s Server Setting tab Once you have logged in go to the Click amp Go Logic tab and click Run in the Ruleset Management bar This will activate the ruleset and the 10Logik E2262 will begin Active Ethernet I O operation When the ruleset has been activated it will remain active even when the ioLogik E2262 is disconnected from the host computer or from the network If the ioLogik E2262 is turned off Active Ethernet I O operation will resume when it is turned back on This allows you to use the ioLogik E2262 for PC independent automation Ruleset Management Bar Clear The Clear command erases the ruleset in both ioAdmin and in the ioLogik E2262 Retrieve The Retrieve command copies the ruleset from the ioLogik E2262 into ioAdmin Download The Download command copies the ruleset from ioAdmin onto the ioLogik E2262 Run The Run command starts Active Ethernet I O operation using the ruleset that the ioLogik E2262 booted up with Stop The Stop command stops Active Ethernet I O operation Ruleset Import Export Although rulesets alone cannot be imported and exported the entire system configuration including the current ruleset can be imported and exported As you make changes to a ruleset you can export the system configuration in order to save that ruleset 5 8 A Liquid Crystal Display Module LCM The ioLogik E2262 supports an optional detachable Liquid Crystal Display Module LCM for easier field maintena
29. channel Please note that you can press Reset to default on the Navigation Panel to reload the factory default value and ignore the user calibrated value The default value is calibrated in the factory and is stored in the device ioLogik E2262 User s Manual Utilities TC Channel 6 x Calibration Sensor 1 Make sure that the range that needs calibrating is currently selected 2 Apply the zero input signal such as icing water to the channel to be calibrated 3 Walt about 30 seconds for the input to settle and be read 4 Click on the Calibrate button The calibration will continue 5 The page will show Calibration Completed while finishing the calibration process Warning 1 Don t remove the sensor during the calibration is going 2 You can reset the parameter by pressing Reset to default Calibrat Total progress Alias Name Click the Alias Name tab to customize the channel name You may use names with up to 16 characters If you already set the Alias Name on I O Configuration page the channel name will appear on Click amp Go Active message and Web Configuring Digital Output Channels The ioLogik E2262 is equipped with 4 digital output channels that can be set individually to DO or Pulse Output mode DO Channel 0 HOY ca Config Test 1 Mode Settings Pulse mode parameter Mode DO v 2 Power On Settings DO status Pulse mode parameter OFF v ja 3
30. ded you use this method to back up your configuration after you have finished configuring the ioLogik for your application The following is an example of the exported configuration file 3 19 ioLogik E2262 User s Manual Utilities loLogik E226 Network NG Server Configuration Date 200804 19 Tima 11 45 13 Framar WI 1 Modal 0 Baild00041310 MOD TYPE E2262 Active Fthemet LO Sarver TC 400 MOD LOC MOD NAME 2 10 Configurations TEOT TOOT TONO TC TERA TE TOM IE TOOR TCO TC TOOR TOOR EO TORT TOE TCI1 0 CC TCL TC TCO TEIE Sansor Typo 1 E TYPE Esabk 1 Sensor Typo 1 E TYPE Frabls 1 Sansor Type 3 E TYPE Frabls 1 Sensor Typo 1 E TYPE Frabls 1 Sensor Type l E TYPE Ezabla 1 sensor Typo 1 E TYPE Euabla 1 Sansor Typo 1 E TYPE Ezabla 1 Sensor Typo 1 E TYPE Ezable 1 Sanser Typa 20 Araraze Eunabd 1 Sansor Type 20 Araraza Enabls 1 Sansor Type 20 Araraza Fnabls Sensor Type 20 Averaga Enabla Sansor Type 20 Ararags Enabls 1 Sensor Typa 20 Araras Enabls 1 Sensor Type 20 Avars Enabla 1 Import System Config Formal z Formal Formela Formula Formela Formela Eoemela il Select this command to reload a configuration that was exported to a text file You will need to log in as an administrator to use this function You will need to restart the ioLogik server in order for the new configuration to
31. dress e Mail Address Mail Server Settings Global Settings SMTP Server Address Login Mame Login Password 5 7 ioLogik E2262 User s Manual Click Go Logic Working with Click amp Go Rulesets Activating the Ruleset A Click amp Go Logic ruleset contains up to 16 rules that act as the brain of your Active Ethernet I O system The Click amp Go Logic tab lists the rules in the current ruleset which work together to determine what I O information is sent who it is sent to how it is sent and under what I O conditions it is sent This simple but powerful tool is significantly more efficient with network and CPU resources than traditional blanket polling methods By default the ioLogik E2262 operates as a passive remote server In order to operate as an Active Ethernet I O server you must define a ruleset and then perform the following three steps 1 The ruleset must be downloaded from 10Admin onto the 10Logik E2262 You can do so by clicking on Download in the Ruleset Management bar After the ruleset has been downloaded the ioLogik E2262 must be restarted You can do this by right clicking on the server name in the navigation panel in ioAdmin and selecting Restart Do not use the reset button as that will load all factory defaults and erase your ruleset from memory After the 10Logik E2262 has restarted the ruleset must be activated for Active Ethernet I O operation First you will need to log in as an administr
32. e Active Ethernet I O server intelligently sends the host computer status information under user specified conditions This is a report by exception approach which greatly reduces the load on CPU and network resources Network packets are far fewer in number and far smaller in size since I O information is only sent when necessary and only information from the specified I O device is sent Based on field tests of an ioLogik E2000 series server used in an RFID system 50 ms is the typical response time over a 100 Mbps Ethernet network Moxa s active I O messaging system uses TCP or UDP for I O messaging and supports sending messages to up to ten host computers simultaneously In addition to providing intelligent status reporting Active Ethernet I O servers are backwards compatible with all of the functions and capabilities of traditional passive remote I O servers Click amp Go Moxa developed the Click amp Go Logic control interface for easy configuration and deployment of Active Ethernet I O Click amp Go s intuitive graphical interface lets administrators use simple IF THEN statements as rules to determine how the Active Ethernet I O server responds to different I O conditions For example the Active Ethernet I O server could be programmed so that if the temperature recorded by an attached sensor reaches a certain value an attached switch is turned on and an e mail is sent to an administrator Click amp Go makes it easy to define a set of th
33. e and take the appropriate action when the I O status satisfies a user defined condition For example the ioLogik E2262 could be configured to send a TCP UDP message only when a temperature sensor attached to TC 00 reports a reading of 85 C This structure results in a much improved response time and a much reduced load on the host computer s CPU and on network bandwidth Click amp Go Logic was developed to provide an easy and intuitive way to configure when and how I O information is transmitted over the network Using simple If Then statements you set the conditions that need to be satisfied and the resulting actions Up to three conditions and three actions can be combined in any one rule and up to 16 rules can be defined in a ruleset Each SNMP trap or TCP UDP message can be transmitted to up to 10 computers simultaneously Features Click amp Go Logic s key features are as follows e Easy local logic control with intuitive If Then construction e Up to 16 user defined rules e Up to 3 I O based conditions and 3 DO or network actions per rule e Email TCP UDP or SNMP trap for active I O messaging e Customizable message content with dynamic fields for time date IP address and more e Up to 10 simultaneous IP destinations for TCP UDP messaging e Configurable interval for time triggered events Click amp Go Logic Basics To use Click amp Go Logic open ioAdmin and log on as an administrator on the Server Settings tab Once yo
34. eated for each day with file names assigned automatically You can also select the color of each event type in the log 3 23 ioLogik E2262 User s Manual Utilities Checking Connected Devices You can see which I O servers is already connected to ioEventLog by selecting Connected Device List from the Connection menu You will be prompted to view which devices are connected Connected Device List 208 Opening Log Files You can view previously saved logs by selecting Open from the Log menu You will be prompted for the data that you wish to view a z Date of Log File iim Ed Select date of lag file to view ET May 2007 Sun Mon Tue Wed Thu Fri l2 3 4 E 7 TE 5 Pali 11 13 14 15 16 17 18 20 21 22 3 24 25 ef 28 29 30 31 T3Today 5 10 2007 x Cancel The logs for the day that you select will be displayed in the Alarm Log Viewer window Clearing the Log If you wish to clear the log you can select Clear from Log menu This will clear all events for the current day The cleared events will not be saved in that day s logs After the logs are cleared new events will be displayed and recorded as usual 3 24 4 Using the Web Console You can use the ioLogik E2262 s built in web console to configure many options The following topics are covered E E E LUUL Introduction to the Web Console Basic Settings Network Settings gt General Settings gt Ethernet C
35. entLog is installed along with ioAdmin form the Document and Software CD It is designed to help you keep a record of ioLogik status events over the network The log is stored on the Windows PC You will need to set up your ioLogik to send status events to the PC s IP address The following events are monitored e cold start e warm start For each event the following information is provided The log can be sorted by any of these fields e Event type e Event date and time e joLogik s source name e Source IP e Destination IP e Host date and time e Source model 3 22 ioLogik E2262 User s Manual Utilities System Connection Log Source IP Destination IP Host Date Time Source Model 0 00 02 35 10 16 51 Active Client Connections 1 Configuration In the System menu select Settings to configure ioEventLog Alarm Listen Por Port 4040 Log Director Directory C Program Files ova domino NU tility slog Screen Cola Event Type Color Cold Star Mee Warn Start cca vi Off Line More y On Line M cGen gt The Alarm Listen Port is the TCP port number that will be monitored for status events You can modify this setting as necessary to receive signals through a firewall It will need to match the settings for the 10Logik that is being monitored The Log Directory is where the log files will be stored The default directory is C Program Files Moxa ioEventLog log A separate log file is cr
36. entered in HEX by selecting the Send as HEX checkbox When sending a message in HEX each HEX value must be delimited by commas Certain control characters will only appear in the Message Monitor when Toggle HEX is selected as in the following example E Message Content Settings HO Message Content 01 02 08 31 32 49 50 51 52 GP jv Send as HEX seperated by 33 max chars 200 _ Server Settings Se Network 1 0 Configuration de Server Info Message Receiver list global Messaging protocol global go maa Watchdog Sy Click amp Go Logic Message Monitor 1 Dest IP 192 168 127 2 UDP UDP TCP 3 Dest IP 0 0 0 0 4 Dest IP 0 0 0 0 Message Port TCP UDP 5 Dest IP 0 0 0 0 3000 Copy D Clear 6 Dest IP 0 0 0 0 MG Y 170 Configuration W Server Info EF Server Settings Be Network a a Firmware Update Watchdog Y Click amp Go Logic Message Monitor 8 Dest IP 0 0 0 0 UDP TCP a oO saa 09 010203313249505152 Dest IP 0 0 0 0 IE Y Toggle HEX 5 5 ioLogik E2262 User s Manual Click amp Go Logic SNMP Trap Select SNMP trap along with a trap number between 1 and 20 You may need to consult with your network administrator to determine how trap numbers will be used and defined in your network Click the memo icon to specify up to 10 IP addresses to receive the SNMP trap You can also bind the status of
37. er Settings Message Monitor UDP TCP Copy D Clear M Toggle HEX Messages can be displayed in ASCII or in HEX To display messages in HEX make sure that Toggle HEX is checked 3 9 ioLogik E2262 User s Manual Utilities loAdmin Administrator Functions AN For full access to all configuration options log in as an administrator in the Server Settings tab This is required whenever you start up ioAdmin or boot up restart the ioLogik E2262 When you install the 10Logik E2262 for the first time the password will be blank and you can simply click Login Additional functions will available after logging in including the following new tabs Be Network x2 Firmware Update 8 Watchdog Click amp Go Logic When making configuration changes you will need to click Update or Apply to save the changes Some changes will require a restart of the ioLogik E2262 in order to take effect and you will be given the option to restart the computer if necessary ATTENTION You MUST log in to access any administrator function including Network Communication Watchdog Timer and Firmware Update tabs If you forget the password you can hold down the 10Logik s reset button to clear the password and load factory defaults This will result in the loss of all configuration settings and your Click amp Go Logic ruleset O Configuration Tab Administrator When logged on as an administrator you can double click on a channe
38. er the 10EventLog section later in this chapter ioLogik E2262 User s Manual Utilities Y 1 0 Configuration W Server Info V Server Settings Network x2 Firmware Update 8 Watchdog Y Click amp Go Logic Message Monitor Password for entry 1 Logout Management Settings Time Settings Change Password 8 char max Local Date 2007 21213 217428 Reconfirm Password Time 4 124 AE v Update Time Zone Server Name GMT Greenwich Mean Time Dut E2260 Test2 Y Time Server Server Location Location2 Y Y System Log Server Address 192 168 127 2 Port 4040 Y C Refresh Network Tab The Network tab is where you configure IP settings Modbus TCP Alive Check Timeout settings DNS settings Serial settings SNMP settings and Web Access settings for the ioLogik E2262 Y 1 0 Configuration Fi Server Info EN Server Settings ka Network x2 Firmware Update 8 Watchdog Y Click amp Go Logic Message Monitor Number of Modbus TCP connection s 2 IP Settings Serial Settings IP Configuration Static vi Unit ID 1 IP Address 192168127210 Ree ur Subnet Mask 255 255 255 0 00 Stop Bits 1 Casual TS Parity 5 None MAC 00 90 E8 0E E0 15 oo Ei Ei ae Accessible IP Modbus TCP Alive Check Timeout SNMP Settings Enable Modbus TCP idle connection V Enable SNMP timeout interval Fen pubic 60 E sec Write Community private 0000 Contact A DNS Settings ua DNS 1
39. es by using a combination of IP address and netmask as follows To allow access to a specific IP address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask To allow access to hosts on a specific subnet For both the IP address and netmask use 0 for the last digit e g 192 168 1 0 and 255 255 255 0 8 To allow unrestricted access Deselect the Enable the accessible IP list option Refer to the following table for additional configuration examples Allowed Hosts IP address Netmask Anyhost Disable 192 168 1 120 192 168 1 120 255 255 255 255 192 168 1 1 to 192 168 1 254 192 168 1 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 to 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 to 192 168 1 254 192 168 1 128 255 255 255 128 ioLogik E2262 User s Manual SNMP Agent Using the Web Console On the SNMP Agent page you can enable SNMP and set the read and write community strings The ioLogik E2262 supports SNMP v2 Simple Network Management Protocol to allow monitoring of network and VO devices with SNMP Network Management software It is useful in building automation and telecom applications 33 Overview Basic Settings 10 Network Settings I 1 0 Settings S3 System Management OG Accessible IP Settings EE 7 of 0 Network Connection 9 Firmware Update 2 Import System Config 2 Export System Config 1 LCM
40. ese rules which will become the basis for your Active Ethernet I O system 1 2 ioLogik E2262 User s Manual Introduction Optional Liquid Crystal Display Module LCM In order to make user easy view the ioLogik E2262 supports an optional hot pluggable Liquid Crystal Display Module LCM for field management and configuration The LCM can display network and I O settings such as temperature value The ioLogik E2262 s IP address and netmask can also be configured using the LCM and one LCM can be used to maintain and configure all ioLogik 2000 devices Product Features e Click amp Go Logic for easy configuration of your Active Ethernet I O system e High speed active I O messaging e 8 input channels for various thermocouple temperature sensors such as J K T E R S B and N type TC sensors and more with software selectable filtering time e 4 channels for 24 VDC output with Pulse Output mode and software selectable pulse width e 10 100 Mbps Ethernet supporting Modbus TCP and up to 10 hosts e Windows utility and quick programming library for VB VC BCB coming soon e Expandable I O through optional RS 485 modules e Supports SCADA software including InTouch Citect and 1F1x32 e SNMP for system management and I O status e Remote management over the network including firmware updates e Supports TFTP server to import configuration e Power on and safe status settings for digital output e Optional hot pluggable LCM for sta
41. esponds to the sensor ranges shown above For example for a K type TC sensor a count value of 10 corresponds to a 0 1 C reading Moxa can only guarantee accuracy within the ranges shown above Be sure to verify the sensor type Accurate readings beyond these ranges cannot be guaranteed Virtual Channels The ioLogik E2262 provides virtual channels so you can easily determine the average or deviation values for any attached temperature sensor A virtual channel can operate in Average Mode or Deviation Mode In Average Mode up to 8 physical channels are selected and the virtual channel reports the average value of the selected channels In Deviation mode two physical channels are selected and the virtual channel reports the difference between the channels When using virtual channels if there are errors on any of the selected physical channels that channel s readings will simply be ignored You can refer to the LED indicators to see if any errors are encountered with any of the physical channels Note that virtual channels only support temperature units and cannot be used with resistance units Any channel that is connected to a mV voltage input will be treated as an error channel Calibration The ioLogik E2262 allows you to calibrate the TC sensor by user In each channel configuration section click Calibration and then follow the onscreen instructions to start the TC sensor calibration Each calibration needs about 20 seconds per
42. et button to load the factory defaults Before you set a password for the first time it is a good idea to complete the ioLogik s configuration and export the configuration to a file The configuration can then be easily loaded imported back into the 10Logik E2262 if it has been reset to factory defaults Load Factory Default This function will reset all of the ioLogik E2262 s settings to the factory default values All previous settings including the console password will be lost Save Restart If you change the configuration do not forget to reboot the system 4 10 5 Click Go Logic Click G0 Logic was developed by Moxa to provide an easy way to program your ioLogik E2262 for active I O messaging In the chapter we will show you how Click amp Go Logic works and how to use it to develop your active I O messaging program The following topics are covered in this chapter Q Overview LJ Features LI Click amp Go Logic Basics gt Working with Rules LI Defining Logic Rules gt Summary of IF THEN Parameters gt IF Conditions gt THEN Actions Q Working with Click amp Go Rulesets gt Activating the Ruleset gt Ruleset Management Bar gt Ruleset Import Export ioLogik E2262 User s Manual Click 4Go Logic Overview The ioLogik E2262 s Active Ethernet I O system eliminates the need for host computers to continually poll I O devices for status Instead the server itself is able to monitors the status of each I O devic
43. et of IF conditions 1s satisfied Under Relation between condition select AND to specify that all conditions must be satisfied for the action to take place select OR to specify that the action should occur if any one of the conditions is satisfied Instead of performing an action under specified I O conditions you may wish to set up a heartbeat status message or action that repeats at regular intervals as long as the I O server is operational In this case you can set up a Time Trigger rule as the first IF condition For example you can set a 3600 second interval so that a TCP status message is sent every hour THEN Actions Under the THEN column you can set up to 3 actions that will be performed if the conditions under the IF column are satisfied The 3 actions can be any combination of DO status setting SNMP Trap Active Message by TCP UDP or E mail For SNMP Hap Active Message and E mail actions use the following memo icon to additional parameters 5 4 ioLogik E2262 User s Manual Click 4Go Logic Active Message Select Active Message for active I O messaging over TCP or UDP Click the memo icon to configure the message and parameters Note that TCP and UDP cannot be used at the same time within a ruleset all rules must use the same protocol After clicking the memo icon you can enter your desired message in the Message Content window Dynamic fields such as time date IP address and I O status can be inserted in you
44. ied in the Host Connection Watchdog each output channel will be reset to its Safe Status settings Note that the Host Connection Watchdog is disabled by default If the Host Connection Watchdog 1s disabled the Safe Status settings will have no effect You can configure whether or not the DO is set to OFF or ON for Safe Status For DO channels in Output Pulse mode you can configure whether or not the output pulse commences or continues for Safe Status 3 13 ioLogik E2262 User s Manual Utilities Test DO You can test the DO channel by using ioAdmin DO Channel 0 0G DO Mode Pulse Output Mode Status DO DO set the DO to ON or OFF DO Pulse activate or stop pulse generation Alias Name Click the Alias Name tab to customize the channel name You may use names with up to 16 characters If you already set the Alias Name on I O Configuration page the channel name will appear on Click Go Active message and Web Server Settings Tab Administrator You can set up a password server name location date time zone and time server in the Server Settings tab 10Admin supports long server names and a location description up to 58 chars If you will be using 10EventLog to receive server status reports such as for warm or cold starts indicate the IP address and port number for the PC that will be running ioEventLog in the System Log field The default port number is 4040 For additional information please ref
45. ioLogik E2262 User s Manual First Edition May 2008 www moxa com product MON 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited ioLogik E2262 User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks MOXA is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This manual might include unintentional technical or typographical errors Changes are made periodically to the information herein to correct such errors and these changes are i
46. is designed as you intended ATTENTION The unit of measurement is defined on the I O configuration tab When an I O channel is being used in a Click amp Go Logic rule the channel s range and units can not be modified 5 3 ioLogik E2262 User s Manual Click Go Logic Defining Logic Rules Each rule consists of two columns The IF column defines I O conditions and the THEN column defines actions When the ioLogik detects that the IF conditions have been satisfied the THEN actions will be performed Summary of IF THEN Parameters TK Max value 4 294 967 295 Time Trigger Max value 4 294 967 295 for Condition 1 only time interval SNMP Trap Details below IF Conditions Under the IF column you can set up to 3 IF conditions As soon as the IF conditions are satisfied the THEN actions are performed For example an alarm can be activated when a temperature exceeds a certain level Use the pull downs to specify the conditions and units of measurement e g TC 00 gt 60 C The available operators are lt gt lt and gt You may want an action to be repeated for as long as the conditions remain satisfied For example instead of simply turning on an alarm you may wish to send an alert message every five minutes for as long as the temperature exceeds a certain level You can set a repeating interval in the Check every ___ sec field The THEN action will be repeated at the specified interval for as long as the s
47. l in the I O Configuration tab to configure that channel s settings A window will open with configuration options for that channel Settings made in this window can be copied to all I O channels using the Apply to all channels option Options for Power on Settings and Safe Status Settings are also available Configuring Thermocouple Input Channels The ioLogik E2262 provides 8 fixed physical TC input Thermocouple channels each supporting up to 8 different types including J K T E R S B N types and mV voltage inputs The TC channels are numbered from channel 0 to channel 7 Moreover channel 8 to channel 15 are virtual temperature channels that report a running average or difference of selected TC channels VM Enable 7 TC Channel Settings TC Channel Settings Sensor Type Settings Sensor Type Settings Sensor fk Type v 200 0 12500 C Temperature Unk Settings Temperature Unit Settings oa m ME og c C ES Virtual Channel Settings Virtual Channel Settings C Average T Channel 0 7 Channel 1 T Channel 2 Channel 3 Channel 4 Channel 5 T Channel 6 Channel 7 C Difference Temperature Unit E KN 3 10 ioLogik E2262 User s Manual Utilities The following table 1s a list of supported sensor types and ranges Type Temperature Range Count Range Ur sc wo soro soo win me 17 600 pf awe wo 100 Goo w 17000 The status of attached sensors will be reported by the count value which corr
48. lly detects IP conflicts between ioLogik E2000 units If 10Admin detects an IP conflict a window will appear that allows you to resolve the IP conflict immediately and restart each unit 10Admin also includes Click amp Go Logic control for the configuration of your Active Ethernet I O system 10Admin consists of following software e joAdmin with Click amp Go Logic e ioLogik 2000 Wiring Guide e ioLogik 4000 Wiring Guide Features of ioAdmin Remote Management Over the Ethernet network 10Admin allows users to e Find and configure multiple ioLogiks e Monitor and configure attached I O devices e Test I O devices e Reset the 10Logik On line Wiring Guide e aan An on line wiring guide can be opened from a SIMMI within ioAdmin for your convenience The easily 0 EE MORA j ae accessible wiring guide can save administrators of much time while planning or troubleshooting magi ss pe Ma Err EE TEE EEUE 3 2 ioLogik E2262 User s Manual Utilities Configuration File 10Admin allows the entire configuration of the ioLogik E2262 to be saved as a file The file is viewable as text and can serve three purposes as a record or backup of configuration as a template for the configuration of other Date 20080419 Tima 11 45 13 Faerwera VIO Bodlad804 1310 1 Modal MOD TYPE E2262 Active Eiharmat LO Sarver TC 400 MOD LOc MOD HAME SETVETS e asa quick reference guide for you to configure Modb
49. lt IP settings IP Address 192 168 127 254 255 255 255 0 Configure the host PC s IP address to 192 168 127 xxx xxx from 001 to 253 so the ioLogik will be visible on the network In Windows you will need to do this through the Control Panel 3 Use ioAdmin or the web console to detect the 10 Logik E2262 Once the 10Logik E2262 has been detected modify the settings as needed for your network environment then restart the ioLogik E2262 For information on ioAdmin please refer to Software Installation later in this chapter Setting the RS 485 Baudrate The RS 485 port on the ioLogik E2262 is reserved for connecting to another ioLogik R2000 I O server The RS 485 port can run Modbus RTU or I O command sets The baudrate is set by a physical dial on the back of the ioLogik E2262 The default settings are baudrate 115200 parity check N data bits 8 and stop bit 1 Baudrate for RS 485 Dial setting and corresponding baudrate parameters are N 8 1 0 115200 1 57600 2 38400 3 19200 4 9600 5 4800 6 2400 7 1200 Remember to restart the 10Logik E2262 after making any changes to the RS 485 baudrate ioLogik E2262 User s Manual Initial Setup Adding More VO Channels A cost effective way to add more I O channels to your ioLogik E2000 VO server is to attach the appropriate 10Logik R2000 I O server The two servers can be snapped together using the RS 485 system bus connector as shown in the following figure Digital I O ch
50. nce The LCM is hot pluggable and can be used to configure the network settings or display other settings When plugged in the LCM displays the ioLogik E2262 home page and pressing any button takes you into the settings and configuration LCM Controls The up and down buttons navigate between the current options The right and left buttons enter and exit the submenus The center button 1s used when modifying settings or restarting the server Down go to the next item Left exit the current submenu and return to the previous menu go up one level Right Jenter the selected submenu go down one level enter exit editing mode An e in the upper right hand corner of the display indicates that the parameter can be modified Press the center button on the LCM to modify that parameter s settings LCM Options Display Explanation Actions lt ioLogik E2262 gt This is the default home page showing the IP address Press the down button to view the submenus Enter this submenu to display information about the specific server you are viewing serial number SLOLOGIK E2262 gt name server location E2262 f w ver lem f w ver model name ioLogik E2262 User s Manual Liquid Crystal Display Module LCM Display Explanation Actions Enter this submenu to display information and settings for the network e ethernet link MAC address 10Log ik E2262 gt IP mode network IP address netmask gateway DNS se
51. ncorporated into new editions of the manual Technical Support Contact Information www moxa com support Moxa Americas Moxa Europe Toll free 1 888 669 2872 Tel 49 89 3 70 03 99 0 Tel 1 714 528 6777 Fax 49 89 3 70 03 99 99 Fax 1 714 528 6778 Moxa Asia Pacific Moxa China Beijing office Tel 886 2 8919 1230 Tel 86 10 6872 3959 60 61 Fax 886 2 8919 1231 Fax 86 10 6872 3958 Chapter 1 Chapter 2 Chapter 3 Table of Contents MOUNT 1 1 EN dle A A E a 1 2 Traditional Remote VU Diana ici 1 2 Acne ENCINO asia laa 1 2 CEKA GO veie 1 2 Optional Liquid Crystal Display Module LCM 00777777 ee ee ee Re Ee 1 3 Product Features ode beds no EE ee ee ee ea ee N Ek 1 3 Packing TEISE a EG GR De Oe tant be EG SE ee EG dent er ee 1 3 Fot SENJA 1 4 Physical D eAvis aske ES ee 1 6 VW CD Mode una een 1 6 Without ECD Modules scannen 1 7 Hardware Reteretice saa 1 7 Panel Gd indolora naa Ae 1 7 LED Indicators staves ie a A DIA 1 8 Nila SUID NN ea Ee Ee De ee Ee GE GE Oe 2 1 Hardware lista lation ainsat Ee Fe ee Ge ee 2 2 Connecting the Powell saa Aa ab EE 2 2 Groundine the 10L091K HO zn 2 2 Connectine tothe Networks AA NA 2 2 Setting the RS 485 Baudrate aa aa Ve Rg De Re kn ve lekk e 2 2 Adding More VO Channels dr ses es N u a E 2 3 Soitwaie TOG 2 3 Ed IE MO EE EE vane deve EA N EA EE 3 1 ON LAAL NLA NTN 3 2 Fess Oo Ad DEE a A N 3 2 NNM SEN 3 4 Man SENNA 3 4 Wine SULA sv 3 5 Mena POC ee ER oc eo EE 3 5 M
52. o Tab Server information such as firmware revision 1s displayed in the Server Info tab Unit ID for MODBUS ATU Vendor Name Product Name Firmware Version Firmae Release Date Cick amp Go Version DNS Server Address DNS2 Server Address Pop AA IN NA 3 8 ioLogik E2262 User s Manual Utilities Server Settings Tab General The Server Settings tab is where you log in as an administrator This is required in order to gain access to the 10Logik E2262 configuration options If no administrator password has been set up simply click Login and leave the Password for entry field blank Please refer to the ioAdmin Administrator Functions section later on in this chapter for more detail Y ro Configuration W Server Info V Server Settings Message Monitor Password for entry E Login F Management Settings Time Settings Y Update N Update I Update System Log dl Message Monitor Tab The Message Monitor tab will display any TCP UDP I O messages received from the ioLogik E2262 When you install the ioLogik E2262 for the first time the Click amp Go ruleset will not have been defined yet so no messages will be displayed Please refer to Chapter 5 for information on using Click amp Go Once a ruleset has been ddefined and activated any TCP UDP messages sent from the 10Logik E2262 will be displayed in the Message Monttor tab Y 1 0 Configuration Fi Server Into P Serv
53. on parameters cannot be modified If you wish to adjust the baudrate you will need to use the physical dial on the back panel of the ioLogik E2262 SNMP Settings The ioLogik E2262 supports SNMP v2 Simple Network Management Protocol to allow monitoring of network and I O devices with SNMP Network Management software It is useful in building automation and telecom applications Use these fields to enable SNMP and set the read and write community strings Web Access Settings This field enables and disables the ioLogik E2262 s web console The web console allows the configuration of many settings using a web browser that is directed to the server s IP address If the web console is not enabled in this field you will not be able to access the web console Firmware Update Tab The ioLogik E2262 supports remote firmware updates through the Firmware Update tab Enter the path to the firmware file or click on the icon to browse for the file Click Update to update the firmware The wizard will lead you through the process until the server is restarted 1 0 Configuration Server Info Server Settings My Network 22 Firmware Update Watchdog Y Click amp Go Logic Message Monitor Firmware File Path E See a ee Warning 1 The firmware download may take around 2 minutes 2 Disconnecting power or network cable during the time would lead to firmware corruption By Updete Step 2 2 Total progress WARNIN
54. onfiguration gt RS 485 Settings VO Settings gt TC Channels gt DO Channels System Management Accessible IP Settings SNMP Agent Network Connection Firmware Update Import System Config VVV VV Y Export System Config LCM Change Password Load Factory Default Save Restart ioLogik E2262 User s Manual Using the Web Console Introduction to the Web Console The ioLogik E2262 web console is a browser based configuration utility When the 10Logik E2262 1s connected to your network you can enter the server s IP address in your web browser to access the web console Note that although most configuration options are available in the web console some settings are only available through ioAdmin Furthermore the web console can be disabled under Web Access Settings in ioAdmin If you are unable to access the web console check the Web Access Settings in 10Admin Total Solution for Industrial Device Networking N Main Menu E2262 E y E Welcome to ioLogik Series 3 Overview SC ic Setti Main L HON EE Active Ethernet I O Server M ma i a ER Settings EE EO E2262 i woe Window 1 1 0 Settings Serial Number 00004 ao eS H _J System Management Firmware Version V1 0 Byildo8b415 10 LCM Ethernet IP Address 492 168 127 254 i Ethernet MAC Address 00 90 e8 0d 0e 49 q Change Password gt RS 485 Setting 115200 n 8 1 N avigation u Load Facto Bafa si AAA Panel E Save Restart The left panel is the na
55. ption during the time 4 8 ioLogik E2262 User s Manual Using the Web Console Import System Config On the Import System Config page you can import a configuration onto the 10Logik The configuration file must have been generated by ioAdmin or through the web console This function can be used to duplicate settings between ioLogiks You will be prompted for the location of the configuration file 1 e 1k2262 txt ao E Import System Configuration File verview Ga Basic Settings sa Network Settings sa 1 O Settings se System Management i Accessible IP Settings Warning PE a 1 The file import process may take around 10 seconds ig SNMP Agent 2 Disconnecting power or network cable would lead to system configuration file corruption during the time Choose a system configuration file path CJ Network Connection Ga Firmware Update E Export System Config LOM i Change Password m Load Factory Default O Save Restart Export System Config On the Export System Config page you can save the ioLogik s configuration into a file for backup or import into another 10Logik server 3 Main Menu E2262 Export System Settings Overview Basic Settings 5 Network Settings A I O Settings NGI System Management Accessible IP Settings CJ SNMP Agent LI network Connection CJ Firmware Update LI Import System Config Export System Config ra LEM A change Password Og Load Fac
56. r 192 168 127 253 and ik2260 2 txt for 192 168 127 254 A batch file could be written as follows tftp 192 168 127 253 put ik2262_1 txt ik2262 txt tftp 192 168 127 254 put ik2262 2 txt ik2262 txt ATTENTION You can also run TFTP client software open the configuration file and enter the remote server s IP Note that both ASCII and Octet mode are supported When the download process is complete the I O server will reboot WinTFTP Client Pro is a trademark of WinTFTP All rights reserved WinTFTF Client Fro i 2 1 EA Upload Download Abort Settings About Help Exit Remote server Local file name Es te JE bo 4 26 Remote file name Port ea k221 Ots Block size 512 bytes Same as local Bytes sent 7226 EI 3 21 ioLogik E2262 User s Manual Utilities Using ioEventLog Installing io EventLog 10EventLog is a Windows utility provided for the monitoring of the ioLogik E2262 and attached VO devices It can be used from anywhere on the network to monitor the ioLogik E2262 1 Installation from CD Insert the Document and Software CD into the host computer Run SETUP EXE which is located in the root directory The installation program will guide you through the installation process and install the ioEventLog utility 2 Open ioEventLog After installation is finished run ioEventLog from Start gt Program Files 2 Moxa gt IO Server gt Utility gt ioEventLog Basic Functions 10Ev
57. r message by clicking on the Keyword Lookup button Up to 10 IP destinations for the message can be specified in the Message Receiver list The default Message Port is 9000 and this can be modified as necessary to work with your firewall By default messages are sent in ASCII although ioAdmin can display the message in HEX in Message Monitor Message Content p eServer Dates by 14 max chars 200 7 Server Time F E Message Recipient Server IP Protocol Global Settings 1 Dest ip Server Name UDP 2 Dest IP E Server Location C TCP 1 0 Configuration Ww Server lni Serer Settings By Network 3 Dest IP u lt K Type 1 FL 0 status 45 Firmware Update 8 Watchdog Y Click GoLogic A Sa Nas IC 1 gt status UDP rep 4 Dew IP lt E Type Water Tank 2 gt status OE 1AFOR 5 Dest IP N Up to 16 chars 3 gt status 6 Desp TC4 status CXC Temp 5 status BA BAN 7 Dest IP i ae ER Cony D Clear M ioga HES 8 Dest IP lt TC gt status Ovocaa oes EV SaverSali nz r ICG status o y VO Configuration G Server Inio Y Server Setting L lt TCQ gt status AT Frimware Update EG wach og Y Click amp Go Loge Message Monto 10 Dest iP TC 10 gt status UDP rep TC 11 gt status 0203313249505152 lt TC 12 gt status Ea TC 13 gt status _o See Conca lt TC 14 gt status TC 15 gt siskus W Toggle HEX Messages can also be
58. rching for the ioLogik E2262 2 3 ioLogik E2262 User s Manual Initial Setup Auto Searching for ioLogik 10 Servers M E2210 JW E2212 MW E2214 f NEST If ioAdmin is unable to find the ioLogik E2262 there may be a problem with your network settings When multiple ioLogik E2000 units are on the same network remember that each unit has the same default IP address You will need to assign a different IP address to each unit to avoid IP conflicts ioAdmin automatically detects IP conflicts and gives you a chance to modify each unit s IP address in the IP Address columns Click the Set button to reboot the corresponding unit with its new IP address Click the Re Search button to refresh the list of units found by 10Admin WARNING IP address conflict detected modify them to different address before proceeding I O Server IP ddess MAC Address E err 00 90 E8 0E E9 1 Active Ethemet 1 0 Ten 8 2401 TE Fe 00 90 E8 0E E0 15 Active Ethemet 1 0 Server 12DI BDO 00 30 E8 0E E0 2C Active Ethemet 1 0 Server 12D1 8D0 2 4 ioLogik E2262 User s Manual Initial Setup 4 Monitoring I O status Once the ioLogik E2262 is found by ioAdmin you can view the status of all I O devices on 10Admin s main screen reg He TAN ET 8 Host 192168127 4 I G iologk Ep 192168 127 284 EE aa EET NINA ee6000000000000000000000 K Type 1FLJ 00 K Type ES rd 200 012500 20003000 20
59. rver l DNS server 2 Enter this submenu to display information about the ruleset lt iobogik E2262 gt being used by the active I O system click amp go e name status lt ioLogik E2262 gt Enter this submenu to display the RS 485 cascade port settings serial port Enter this submenu to access I O channel status Here are examples of settings that you might see e TC 00 XXX lt 10Logik E2262 gt i o setting Press up or down to navigate through the different I O channels without having to go back to the previous menu lt ioLogik E2262 gt Enter this submenu to see if the web console is enabled or console disabled Select this option to enter an IP address to ping If you get a timeout error it indicates that the E2262 cannot reach that IP address Otherwise the display will show the response time lt ioLogik E2262 gt ping Enter this submenu to display the restart now submenu Enter the restart now submenu to display the restart option Press the center button to modify this option then select enable to save changes and reboot the I O server The disable option has no effect lt 20Logik E2262 gt save restart WARNING Any configuration changes that are made through the LCM will not take effect until the ioLogik E2262 is restarted A 2 B Modbus Mappings Oxxxx Read Write Coils Functions 1 5 15 00001 0x0000 Ibit CHO TC Reset Minimum Value lt R gt Always 0 lt W gt 1 Reset to current
60. s name of channel submit Close re Warming Be sure bo Saves Restart your setting submit Close Warning Re sure to Save Restart your setting The following table is a list of supported sensor types and ranges Ur sc wo 1600 soo wo pf awe 10 100 6000 w 1700 Channels 8 through 15 are virtual channels You can click on a virtual channel to configure whether it will return current averages or deviations for the specified physical channels TC 00 through TC 07 ioLogik E2262 User s Manual Using the Web Console DO Channels On the DO Channels page you can configure each DO digital output channel by clicking on the channel DO Channels can operate in DO mode or Pulse Output mode In DO mode output is either on or off In Pulse Output mode a configurable square wave is generated Im DO Channel Settings LH Overview CJ Basic Settings 5 DO Channel Low Width High Width CJ Network Settings DO 00 a 3 VO Settings DO 01 OG RTD Channels DO 02 ig DO 03 Eg System Management EA LCM 3 Change Password j 3 Load Factory Default Y Save Restart NOTE channel is locked by logic om hittp 192 168 127 254 DO Channel Settings Microsoft Internet Explorer DO Channel 0 Settings Made DO Status Pulse Low Pulse High Pulse Count 1 Current Setting Pulse Output El mH Jk Jb n Pulse Output r 3 Safe Status Setting D
61. set up a static or dynamic IP address for the ioLogik E2262 as well as the subnet mask and gateway address 33 Overview OG Basic Settings Ethernet Contigurations HEY Network Settings 4 General Settings 3 CJ RS 485 Settings I O Settings Ethernet Parameters IP Configuration IP Address Static v 192 168 127 254 Subnet Mask 255 255 255 0 Gateway 0 0 0 0 System Management LCM Change Password J Load Factory Default Save Restart ioLogik E2262 User s Manual Using the Web Console RS 485 Settings On the RS 485 Settings page you can view the serial communication parameters but no configuration changes are allowed The baudrate can only be configured by the physical dial on the back of the ioLogik E2262 This is a reserved function RS 485 Settings Ga Overview ie Bas c jaga Serial Parameters a Network ed Unit ID 0x01 i General Settings Baud Rate 115200 Y Ethernet Configurations Data Bits 8 Stop Bits 1 HE 1 O Settings Parity 20 System Management Ga LCM Ga Change Password Ga Load Factory Default GO Save Restart VO Settings TC Channels On the TC Channels page you can view the status of channels TC 00 through TC 15 which includes both physical and virtual channels You can click the Channel Name to enter settings page on which can set the Alias Name Y Main Menu E2262 i ND Overview TC Channel Settings 1 OJ Basic Settings E Channel
62. tion There will be a message saying Host Connection Lost indicating that Safe Status settings have been activated Click Clear Alarm to exit Safe Status and return to normal operation 10 Configuration db Server Info Ph Server Settings Sr Network x2 Firmware Update 8 Watchdog w Click amp Go Logic Message Monitor Host Connection Monitor i Enable Host Connection Watchdog Timeout value 5 sec Host Connection Lost Alarmed Clear Alarm Click Go Logic Tab The Click amp Go Logic tab is where Active Ethernet I O operation is configured While traditional Ethernet I O involves an I O server that reacts passively to polling requests from a network host Active Ethernet I O involves an I O server that actively reports I O data under user specified conditions Click amp Go Logic is a powerful and easy to use tool to define the conditions for reporting I O data Please refer to Chapter 5 for more information 3 17 ioLogik E2262 User s Manual Utilities Y 10 Configuration ri Server Info V Server Settings Bi Network x2 Firmware Update Watchdog Y Click amp Go Logic Message Monitor Logic Name Changes made in the Click amp Go Logic tab are not effective until the ioLogik E2262 is restarted just like changes made in other tabs Note that when an I O channel is used in Click amp Go Logic its range and units become fixed and cannot be modified Server Context
63. tory Default IU Save Restart Click ik2262 Met to export amp save system settings LCM If you have installed the optional LCM you can view the LCM s status and firmware details on the LCM page P Total Solution for Industrial Device Networking E Main Menu E2210 Overview Basic Settings LCM Module Information i i LCM Module ao Network Settings LCM Module Attached EG VO Settings Firmware Version 1 0 0 0 HE System Management Firmware Release Date 03 01 2006 A Change Password 4 9 ioLogik E2262 User s Manual Using the Web Console Change Password Change Password J Overview Basic Settings H Network Settings 0 1 0 Settings a System Management New password 9 Accessible IP Settings Retype password GO SNMP Agent 3 Network Connection 2 Firmware Update 3 Import System Config 9 Export System Config Password Old password CJ Load Factory Default CJ Save Restart When changing the ioLogik E2262 s password settings you will first need to enter the old password Leave this blank if you are setting up password protection for the first time To set up a new password or change the existing password enter your desired password under both New password and Confirm password To remove password protection leave the New password and Confirm password fields blank ATTENTION If you forget the password the ONLY way to configure the ioLogik E2262 is by using the res
64. tus display and configuration Packing List The ioLogik E2262 1s shipped with the following items Standard Accessories e ioLogik E2262 Active Ethernet I O server e Document and Software CD Optional Accessories e LDP1602 ioLogik liquid crystal display module LCM NOTE Notify your sales representative if any of the above items are missing or damaged ioLogik E2262 User s Manual Introduction Product Specifications LAN Ethernet Protocols Serial Interface Serial Line Protection 10 100 Mbps RJ45 Modbus TCP TCP IP UDP DHCP Bootp SNMP MIB for I O and Network HTTP RS 485 2 wire Data Data GND 15 KV ESD for all signals Serial Communication Parameters Parity Data Bits Stop Bits Flow Control Speed Protocol Built in RTC Thermocouple Input Channels I O Mode Input Impedance Resolution TC Conversion Rate Accuracy Zero Drift Span Drift CMR 50 60Hz NMR 50 60Hz Optical Isolation Supported Thermocouple Types Supported millivolt Resolution Mode Virtual Thermocouple Channels Operation Mode Digital Output Channels On state Voltage Output Current Rating Optical Isolation None 8 1 None 1200 to 115200 bps Modbus RTU Yes 8 thermocouple sensors J K T E R S B and N type TC sensors and mV gt 1 mega ohm 0 1 C 90 ms per channel 0 1 6 uV C typical 25 ppm C 92 dB 92 dB 2 KVrms 3 KVDC Sensor Type Degree Range Count Range
65. u are logged on go to the Click amp Go Logic tab It should appear as follows Y Click amp Go Logic Message Monitor y 10 Configuration W Server Info EN Server Settings E Network x2 Firmware Update 5 Watchdog Logic Name 5 2 ioLogik E2262 User s Manual Click 4Go Logic Click amp Go Logic Tab 1 Logic Name In this field you can assign a name for the set of rules 2 Rules List In this area each rule s conditions actions and status are displayed 3 Ruleset Management Bar In this area you manage the ruleset Working with Rules Rules are the building blocks of your Active Ethernet I O system With rules you define the exact trigger conditions for transmission of I O information as well as the content and destination of that information DO operation can also be automated based on TC trigger conditions In the main screen you will see the list of rules in the current ruleset Double click on a rule to open that rule s configuration window or double click on an empty rule to start a new rule MOZA mak EEE __ lell 3 2 tod EIER TIA Free iclogk lt MB 192185 127 25 ye Eaa The configuration window is where the rule is defined Basic If Then logic is used to set up temperature event based triggers The Equivalent Logic Statement at the bottom shows a real time text based summary of the rule that you are defining It can be a useful way to make sure that the rule
66. us drivers in a SCADA system 2 10 Configuration TOO TC Sanser Typa l E TYPE Frabls 1 i i TOOR Sanser Typo 1 E TYPE Ezable 1 1 File name date and time TOOT Sanser Typo 3 E TYPE Ezabls 1 2 Model information C03 0 12 Sensor Typesl E TYPE Enabla 1 TOOT Sensor Typo 1 E TYPE Esabk 1 3 Modbus addresses TOOS 0 7 Sansor Typo 1 E TYPE Emable 1 TECOU Sensor Typo 1 E TYPE Esabk 1 TOTO Sanser Typo 1 E TYPE Ezabk 1 TEA TC Sensor Type 20 Average Enabls 1 Formala t The file includes the following information TODO TC Sensor Typa 20 Average Euablki l Formeda i TEMA E Sanser Typa H Average Fnabk l Formai TC11 0 0 Sensor Type 20 Average Enabla Formula TCT Somar Typa 20 Ararzze Fnabk l Formula 0 TCI Sansar Typo 20 Araraze Enabk Formula f TCM 0 0 Sanser Typo 20 Arriaga Enabk 1 Formula 0 Select 1 0 Server to Import Server Management List Select Server List File to Import Ber E A Select All 10Admin can import and export a list of ioLogiks that are being managed This file can make it easier to manage all devices on the network and includes the following information X unSelect All v 2 E2260 Test1 E2260 192 168 127 253 v 3 E2260 Test E2210 192 168 127 220 v 4 R2110 Test R2110 192 168 127 254 2 1 Server Name 2 Module Type 3 IP Address 4 Unit ID X Cancel 3 3 ioLogik E2262 User s Manual
67. value 00033 0x0020 1 bit CHO TC Enable lt RW gt 0 Disable 1 Enable ioLogik E2262 User s Manual Modbus Mappings 00041 0x0028 I bit CHO DO Status lt RW gt 0 OFF 1 ON 00042 00043 00044 lt RW gt 0 OFF 1 ON 00046 00047 0x002E CH2 DO Power On Status 00048 0x002F CH3 DO Power On Status lt RW gt 0 OFF 1 ON 00050 00051 00052 lt RW gt 0 Stop 1 Start 00054 00055 0x0036 CH2 DO Pulse Output Status 00056 ibt CH3 DO Pulse Output Status 00057 0x0038 1 bit CH0 DO Power On Pulse Output Status lt RW gt 0 Stop 1 Start 00058 0x0039 CH1 DO Power On Pulse Output Status 00059 0x003A CH2 DO Power On Pulse Output Status 00060 0x003B CH3 DO Power On Pulse Output Status 00061 0x003C 1 bit CH0 DO Safe Mode Pulse Output Status lt RW gt 0 Stop 1 Start 00062 0x003D CH1 DO Safe Mode Pulse Output Status 00063 0x003E CH2 DO Safe Mode Pulse Output Status 00064 0x003F CH3 DO Safe Mode Pulse Output Status ioLogik E2262 User s Manual Modbus Mappings 3xxxx Read Only Registers Function 4 30001 0x0000 1 word CHO TC Value Hi Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30002 0x0001 1 word CHO TC Value Lo Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30017 0x0010 1 word Virtual CH8 TC Value Hi Word lt R gt 0 4294967295 Unit 0 1 Celsius Fahrenheit 0 0001 mV 30018 0x0011 1 word Virtual CH8 TC Value Lo Word lt R gt 0 4294967295 Unit 0 1 Celsius
68. vigation panel and contains an expandable menu tree for navigating among the various settings and categories When you click on a menu item in the navigation panel the main window will display the corresponding options for that item Configuration changes can then be made in the main window For example if you select Basic Settings in the navigation panel the main window will show a page of basic settings that you can configure You must click the Submit button after making configuration changes The Submit button will be located at the bottom of every page that has configurable settings If you navigate to another page without clicking the Submit button your changes will not be retained Submitted changes will not take effect until they are saved and the ioLogik E2262 is restarted You can save and restart the server in one step by clicking the Save Restart button after you submit a change If you need to make several changes before restarting you can save your changes without restarting by selecting Save Restart in the navigation panel If you restart the ioLogik E2262 without saving your configuration the ioLogik E2262 will discard all submitted changes Basic Settings On the Basic Settings page you can set the ioLogik E2262 s system time or provide the IP address of a time server for time synchronization nz i Basic Settings JJ Overview Time Settings Network Settings I O Settings i System Management Local time 2007 09 29