1. Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 Maximum radiant power lt 1mW Emitted wavelength 620 690nm Beam divergence 0 16 x 0 6 mrad Impulse duration 0 2 x 10 s 0 8 x 10 s The device produces visible laser beams which are emitted from the instrument Itis a Class 2 laser product in accordance with IEC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex Z WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous Z CAUTION Looking into the laser beam may be hazardous to the eyes Attach the laser sticker a of your country language Stanley TLM330
2. L fa S 2 sec 2 sec The value from simultaneously the main line can be used for fur Memory is completely de ther calculations leted Calibration Calibration of tilt sensor Tilt Calibration gt 4 N 2 sec simultane Turn the device horizontally by 180 and place it again on absolutely flat sur face Turn the device horizontally by 180 and place it again on absolutely flat surface 16 Stanley TLM330 Turn the device upside down and place it again on absolutely flat surface After 2 sec the device goes back to the nor mal mode Technical Data Distance measurement Typical Measuring Tolerance 1 0 mm 0 04 in Maximum Measuring Toler 2 0 mm 0 08 in ance Range of target plate 100 m 330 ft Typical Range 80 m 262 ft tion Range at unfavourable condi 60 m 197 ft Smallest unit displayed 0 1 mm 1 32 in laser point at distances 6 30 60 mm 10 50 100 m Tilt measurement Measuring tolerance to laser 0 2 beam Measuring tolerance to 0 2 housing Range 360 Laser class 2 Laser type 635 nm lt 1 mW Protection class IP54 dust and splash water protected Autom laser switch off after 90 s Autom power switch off after 180 s Battery durability 2 x AAA up to 5000 measure ments Dimension H x D x W 115 6 x 58 x 32 m
3. Table of Contents Instrument Set up Height tracking Introduction Memory 20 last displays Overview Delete Memory Display Calibration Insert batteries Calibration of tilt sensor Tilt Calibration Operations Technical Data Switching ON OFF Message Codes Adjusting measuring reference tripod Multifunctional endpiece Distance unit setting Warranty Tilt unit setting Safety Instructions Timer automatic release Areas of responsibility Beep ON OFF Permitted use Illumination ON OFF Prohibited use Keypad lock ON Hazards in use Keypad lock OFF Limits of use Measuring Functions Disposalan pou Measuring single distance Electromagnetic Compatibility EMC Permament Minimum Maximum measuring asi NE in U S Add Subtract aser classification Labelling Triangular area Pythagoras 2 point Pythagoras 3 point Pythagoras partial height Stake out Smart Horizontal Mode Stanley TLM330 Instrument Set up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time Z The person responsible for the product must ensure that allusers understand these directions and adhere to them The symbols used have the following meanings Z WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury Z CAUTION Indicates a potentially hazardous situation or a
4. duct specific treatment and waste Electromagnetic Compatibility EMC ZA WARNING The device conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of causing interference in other devices cannot be totally excluded Safety Instructions FCC statement applicable in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that inter ference will not occur in a particular instal lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Laser classification Labelling
5. e behaviour on scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly in the sun Hazards in use WARNING Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measurements ZA CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modifications not expressly approved could void the user s authority to operate the equipment Limits of use Refer to section Technical data The device is designed for use in areas permanently habitable by humans Do not use the product in explo sion hazardous areas or in aggressive environments Stanley TLM330 Disposal CAUTION Flat batteries must not be disposed of with household waste Care for the environ ment and take them to the collection points provided in accordance with national or household waste Dispose of the product appropri Y country Adhere to the national and country specific management can be downloaded from our homepage local regulations The product must not be disposed with ately in accordance with the national regulations in force in your regulations Pro
6. e to the next stake out point is dis played o Ea S En e tal 2625m 0 240 m is missing up to next 0 625 m distance 0em Stanley TLM330 The inclina tion is dis played Range 180 A A A ON Approve value and start measurement When approaching a stake out point to less than 0 1 m the instrument starts to beep The function can be stopped by pressing the CLEAR OFF button Measuring Functions Smart Horizontal Mode gt N m Aim laser at tar get Height tracking This function displays continous ly the tracking height if the device is turned on a tripod No 2nd dis tance measuring is needed as only the angle is automatically measured 8 832 m X 30 2 J B Tracking angle 9 B27 M Y Tracking height if de vice is turned on tripod z an a Za D D32m Y u8g21m _z Aim laser at lower point Stanley TLM330 Press key again to switch off horizontal measure ment up to 360 and a transverse tilt of 10 Aim laser at upper points and angle height tracking starts au tomatically The tracked KAJ height y is in 90 to the 1st 6 aimed point ON lib ti Stops Height tracking and displays last measurement Measuring Functions Memory 20 last displays UNITS HIST _ G 20 last displays are displayed Navigates trough 20 last displays Stanley TLM330 Delete Memory S
7. easured is displayed min max The last value meas ured is displayed in the main line Used to measure room diagonals maximum val ues or horizontal distance minimum values The next meas The next meas urementisadded urement is sub to the previous tracted from the one previous one Add Subtract S Stanley TLM330 Target surfaces Measuring errors can occur when meas uring to colourless liquids glass styrofoam or semi per meable surfaces or when aiming at high gloss surfac es Against dark surfaces the measuring time increases v Stops permanent minimum maximum measuring The result is shown in the main line and the measured value above This process can be repeated as required The same process can be used for adding or subtracting areas or volumes Measuring Functions Area g A e The result is shown in the main line and the measured ON value above Aim laser at first Aim laser at sec I target point ond target point A amp 19 823m Circumference 24 352 ni Area Stanley TLM330 Measuring Functions Aim laser at first target point The result is shown in the main line and the measured value above Aim laser at sec i Aim laser at third ond target point target point B 80 203 m gt Circumference W 205 103 a Wall areas 18 594 m Volume Stanley TLM330 Measuring Functions Triangular area Aim laser at first Aim laser at sec targe
8. esponsible for the instrument must ensure that all users understand these directions and adhere to them Areas of responsibility Responsibilities of the manufacturer of the original equipment Stanley Tools 701 E Joppa Road Towson Maryland 21286 www STANLEYLASERS com www STANLEYTOOLS com www STANLEYTOOLS eu The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument e To understand the safety instructions on the product and the instructions in the User Manual e To be familiar with local safety regula tions relating to accident prevention Always prevent access to the product by unauthorised personnel Safety Instructions Permitted use e Measuring distances Tilt measurement Prohibited use Using the product without instruction Using outside the stated limits e Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screwdrivers etc e Carrying out modification or conversion of the product e Use of accessories from other manufac turers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Deliberate or irresponsibl
9. m 4 55 x 2 28 x 1 26 in Weight with batteries 155 g 4 98 oz Temperature range Storage Operation 25 to 70 C 13 to 158 F 10 to 50 C 14 to 122 F applies for 100 target reflectivity white painted wall low background illumination 25 C applies for 10 to 500 target reflectivity high back ground illumination 10 C to 50 C Tolerances apply from 0 05 m to 10 m with a confi dence level of 95 The maximum tolerance may deteriorate to 0 1 mm m between 10 m to 30 m and to 0 2 mm m for distances above 30 m applies for 100 target reflectivity background illumination of approximately 30 000 lux after user Calibration Additional angle related deviation of 0 01 per degree up to 45 in each quadrant Applies at room temperature For the whole operating temperature range the maximum deviation increases by 0 1 For accurate indirect results the use of a tripod is recommended For accurate tilt measurements a trans verse tilt should be avoided Stanley TLM330 Distance measuring yes Min Max measuring yes Permanent measuring yes Stake out yes Addition Subtraction yes Area yes Volume yes Triangular area yes Pythagoras 2 point 3 point partial height Smart Horizontal Mode yes Indirect height Height tracking yes Levelling yes Memory 20 displays Beep yes Illuminated displa
10. n unintended use which if not avoided may result in minor injury and or appreci able material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Overview Display On Measure Triangle Area Inclination Stake out e f Smart Hori zontal Mode Height N ii a Measuring Ti IN Y N Subtract Clear Off AN Memory Stanley TLM330 Instrument Set up Display Insert batteries To ensure a relia Area ble use do not Volume use zinc carbon MAN batteries Change batteries when battery Measuring symbol is flash reference ing Stake out Circumfer Tag ence IAN EN i OO Pythagoras U Angle AN D i g NO ftim Horizontal Wall area min measurement lt Min Max Indirect height Measuring Addition Subtraction Units 2nd result Main line Stanley TLM330 Operations Switching ON OFF Press ON but ton 2 sec to OFF startcontinuous 1 laser mode If CLEAR no key is 2 sec pressed for 180 sec the device switches off au tomatically Device is turned OFF n w Distance is measured from the front of the device Distance is measured from the rear of the device standard setting Ya Undo last action Stanley TLM330 Ya Leave actual function go to de fault operation mode Message C
11. odes If the info icon appears with a number observe the instruc tions in section Message Codes Example mo S 256 Distance is measured from the tri permanent pod thread ly Operations Multifunctional endpiece Distance unit setting g UNITS HIST Switch between the following units 2 sec 0 000 m 0 00 ft 0 0000 m 0 00 1 32 0 00 m 0 00in 0 in 1 32 Timer automatic release A ka Tilt unit Gi S S UNITS E HIST 2 sec simultaneously Adjust delay of au tomatic release max 60 sec standard setting 5 sec The orientation of the endpiece is automatically detected and the zero pointis accordingly ad justed Switch between the following units 0 0 0 0 Once the key is released with the la ser activated the remaining seconds until the measurement are displayed in a countdown The delayed release is recommended for precise aiming e g at long distances It avoids shak ing of the device when pressing the measurement key Stanley TLM330 Operations Beep ON OFF Illumination ON OFF id OFF M kd 2 sec 2 sec simultaneously i X simultaneously serie pala ON Keypad lock OFF 2 sec simultaneously Stanley TLM330 Measuring Functions Measuring single distance Wy ON WAS ann Aim active laser at target The minimum and maximum dis tance m
12. t point ond target point Angle included by the first A 40 8 two measurements 233852 M en Circumference 24552 m Triangular area Stanley TLM330 Measuring Functions Pythagoras 2 point The result is shown in the main line and the measured dis tance above Pressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Aim laser at up Aim laser rectan per point gular at lower Aim laser at up Aim laser at rec per point tangular point The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maxi mum measurement Stanley TLM330 Measuring Functions Pythagoras partial height Aim laser at up Aim laser at 2nd Aim laser at rec per point point tangular point The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates auto matically Minimum or Maximum measurement Stanley TLM330 Measuring Functions Leveling jui o This function displays continously the inclination of the device From an inclination of 5 the device 1 starts beeping frequently The more it gets to 0 the faster it beeps If an inclination of 0 3 is Me reached the device beeps continu ously Stake out Move device slowly along the stake out line The distanc
13. y yes Multifunctional endpiece yes Message Codes Ifthe message Error does not disappear after switching on the device repeatedly contact the dealer Ifthe message InFo appears with a number press the Clear button and observe the following instructions No Cause Correction 156 Transverse tilt Hold the instrument greater than 10 without any transverse tilt 162 Calibration mistake Make sure the device is placed on a abso lutely horizontal and flat surface Repeat the calibration procedure If the mistake still occurs contact your dealer 204 Calculation error Perform measurement again 252 Temperature too Let device cool down high 253 Temperature too Warm device up low 255 Received signal too Change target surface weak measuring e g white paper time too long 256 Received signal too Change target surface high e g white paper 257 Too much back Shadow target area ground light 258 Measurement Correct range outside of meas uring range 260 Laser beam inter Repeat measurement rupted Care e Clean the device with a damp soft cloth e Never immerse the device in water e Never use aggressive cleaning agents or solvents Warranty The Stanley TLM has a two year warranty For further information on this contact your dealer Subject to change drawings descriptions and technical data Stanley TLM330 Safety Instructions The person r

Download Pdf Manuals

image

Related Search

Related Contents

  陸 上 自 衛 隊 仕 様 書  New-generation MMI System in the Audi Q5  Product Specifications  Manutención y transporte de equipos  User Manual for ARGOS FP Series Products And FlexiSoft  取扱説明書 詳細版  MX-2300N/2700N/3500N/3501N/4500N/4501N Operation  installation tip dato útil para la instalación conseil d`installation  iStarUSA WA-FEET mounting kit  