1. 20 Override Code default flash 1 Follow Section 1 9 to change the Override Code Follow Section 2 6b of the user manual to operate the Override 21 Hazard lights Output default normal When set as Normal Connect the hazard lights output as normal using the Y splitter lead If the Normal connection does not work then connect the hazard lights output to the hazard switch as shown below and set feature 21 as Pulse or Continuous depending on the type of hazard switch Hazard Switch Lights NL Control Unit u i Hazard Lights Output Predator XL3 When selecting Pulse or Continuous try the factory default first 0 5sec If the hazard lights do not flash as expected proceed to the hazard light learning as follows Turn the ignition on and off 3 times on off on off on off The siren will chirp once to confirm the system is in learning mode Turn the vehicles hazard lights on and the hazard lights start to flash Within 10 sec press and hold the valet switch The LED will turn on to confirm the valet switch is pressed Release the valet switch once the hazard lights have flashed 10 times The LED will turn off and siren will chirp once to confirm the learning is complete The system will leave the learning mode automatically if the valet switch is not pressed within 10 sec or if the ignition is turned on 2 SYSTEM UPGRADE Follow the steps below to upgrade the system to a 2 way paging
2. 1 4 Bypass Input red black wire w3 7 This wire is designed for external engine start module or turbo timer Feed this wire with ground when the external engine start module or turbo timer is activated and the system will bypass the ignition input and shock sensor until the ground pulse is removed 1 5 Start Output pink wire w3 9 Press and hold button 4 3 sec later the system will send a 1 sec pulse to activate the external engine start module Pressing button 4 for 3 sec will send the pulse again to deactivate the external engine start module 1 6 Interior Light Supervision green white wire w3 6 If connected The interior light will be turned on for 20 sec when disarming unless the ignition is turned on The interior light will be turned on all the time whilst the alarm is sounding 1 7 Program the Optional Features default 1 chirp Follow the steps below to program the Optional Features For example To program the feature 5 as 15sec Turn the ignition on then off with the system disarmed Within 10 sec press the valet switch 3 times The system enters the programming mode and the siren and LED will be on for 2 sec to confirm To Reset to Factory Default Within 10 seconds press button 4 for 3 sec all the optional features will be reset to the factory default and the siren will sound for 2 sec to confirm leaving the programming mode Within 10 sec press the valet switch 5 times 1
3. fig 1 87a Normally Closed W2 7 87 Normally Open Normally Closed Immobiliser Connection Fail Safe Start On To 12V DC or Acc Acc 87 Off 86 85 fig 2 W2 8 87a Normally Closed 87 Normally Open 1 3 Programming New Remote Controls The included remote controls have been programmed to the system in the factory Follow the procedure below to program a new remote control to the system Turn the ignition on with the system disarmed Within 10 seconds press valet switch 3 times or 6 times if pager upgrade is installed The siren sounds for 2 sec to confirm the system is now in code learning mode Within 10 sec press any button of 1 remote control The siren will sound for 1 sec and hazard lights flash twice to confirm the 1 remote has been programmed to the system and all the previous codes in the system will be erased entirely Within 10 sec repeat for the 2 remote control and again for 3 and 4 remotes as applicable Up to 4 remotes can be programmed to the system The system will leave the code learning mode after programming 4 remotes to the system and the siren will sound for 2 seconds to confirm If no buttons are pressed within 10 seconds the system will leave the learning code mode and the siren will sound for 2 seconds to confirm The system will leave the code learning mode if the ignition is turned off at any time and the siren will sound for 2 seconds to confirm
4. FALCON PREDATOR XL3 Vehicle Security System with Anti Hijack Installer s Manual TABLE OF CONTENTS 1 SYSTEM INSTALLATION sc cscccretieaseissemaneseie presences 2 Lid POWer Ofi anar renee ve ennen akan 2 1 2 NO amp NC Immobiliser Relay Wiring 2 1 3 Programming New Remote Controls 2 1 4 Bypass Input red black wire W3 7 n 2 1 5 Start Output pink wire W3 9 nv an eneen 2 1 6 Interior Light Supervision green white wire w3 6 3 1 7 Program the Optional Features default 1 chirp 3 1 8 Optional Programmable Features ennen 3 1 9 Feature 20 Override Code default 1 flash 4 1 10 Explanation of the Optional Features 4 2 SYSTEM UPGRADE aansmeert meden 8 3 Wiring Diagram annen enen eneen eenen nennen ennen 9 4 Wiring NOTES srie forastecstei netic rte lanl dreds 10 5 Central Locking Wiring nennen eneen 11 1 SYSTEM INSTALLATION 1 1 Power On When powered on the system will remain in the same status it was in when powered off 1 2 NO amp NC Immobiliser Relay Wiring The system offers two ways of wiring the immobiliser as shown below When wired for Normally Open the immobiliser relay is switched on when the alarm is disarmed fail secure When wired as Normally Closed the relay is on when the alarm is armed fail safe Wiring Diagram Immobiliser Relay NO amp NC Normally Open Immobiliser Connection Fail Secure Start On Acc off
5. D at the same time c By override when the system is disarmed The AED will not active under valet mode To disable the AED you must leave the valet mode When the AED is activated the system cannot enter the following modes a Code Learning b Programming Mode c Hazard lights Calibration Mode d Anti hijacking 13 Door Open Alerts default disable When set as Mode 1 The hazard lights will flash when a door is opened with the ignition on until the door is closed or the ignition is turned off The feature will not be activated if the door is opened whilst the ignition is on When set as Mode 2 The hazard lights will flash when a door is opened regardless of whether the ignition is on of off and until the door is closed The feature will be activated regardless of whether the ignition is turned on or off 14 Total Comfort Closure default disable The CH3 wire is designed for the option of automatically closing the windows when arming the system This feature requires that the vehicle has Total Comfort Closure When set as Disable The CH3 output will not be activated when arming the system but can be controlled as follows With system armed or disarmed Press and hold button 1 3 After 1 sec the CH3 output will be activated until button 1 is released When set as 15 30 or 40 sec When arming the system the CH3 will send a 15 sec or 30 40 pulse to close the windows automatically Pressing the
6. If you want to choose 6 as the code then press button 1 once after the LED has flashed 6 times The LED will turn off and siren sound for 1 sec to confirm Press the valet switch within 10 sec to select the next feature for programming 1 10 Explanation of the Optional Features 01 Chirp Confirmation On Off default on When On The siren will chirp once for system arming and twice for disarming With this feature on the silent arm disarm button is still functional When Off The siren will not chirp for system arming and disarming but the hazard lights will flash as normal 02 Door Lock with Passive Arming default disable When Enabled The doors will also be locked when the system passively arms itself 03 Ignition Lock default disabled When set as Ignition The doors will be locked 15 sec after turning the ignition on if all the doors are closed properly The doors will not be locked if a door is not closed or has been opened during the 15 sec countdown Ifthe doors are unlocked during driving they will be locked again automatically after stepping on the brake pedal Brake light wire must be connected When set as Brake Brake light wire must be connected The doors will be locked when the brake is tapped with the ignition on if all the doors are closed properly Ifthe doors are unlocked during driving they will be locked again automatically after stepping on the brake pedal 04 Ignition Unlock def
7. alarm Cut off the Red and White loops next to port W 1 main unit Plug the 2 way transceiver into port W 1 Program the 2 way remotes to the system The original remote controls will not work once the 2 way upgrade has been installed Only EVO 4 button or pager remote controls can be used with the pager upgrade iagram D iring 3 W W1 Plug in 2Way Transceiver W2 1 W2 2 W2 3 W2 4 W2 5 W2 6 W2 7 W2 8 W3 0 W3 1 W3 2 W3 3 W3 4 W3 5 W3 6 W3 7 W3 8 W3 9 L we 1 W6 2 W6 3 W6 4 W7 1 Green lt 4 Ww7 2 Blue lt 4 GE White Red lt To ground or 12V depending on polarity of W2 2 ES White Hazard lights output built in relay Black lt W W To ground 49Yellow lt Ignition trigger input Red lt ___ To 12V battery Brown Siren Horn output 1A Orange Black Immobiliser output normally open 500mA Orange mmobiliser output normally closed 500mA Green lt Door trigger input Purple lt Door trigger input PBlack Red To footbrake light Gray Boot release output 500mA Gray black _P Total Comfort closure output 500mA Blue White _ Door unlock2 output 500mA Green White gt P Interior light output 500mA Red Black Bypass input from optional remote starter module Blue
8. ault disable When set as Driver After parking the car the drivers door will be unlocked when turning the ignition off When set as All After parking the car all the doors will be unlocked after turning the ignition off 05 Door Lock Time default 0 8 When set as 0 8 sec The system will send a 0 8 sec pulse when locking the doors When set as 3 6 sec The system will send a 3 6 sec pulse when locking the doors When set as 0 8 sec 2 The system will send two 0 8 sec pulses when locking the doors When set as 0 8 sec 15 sec The system will send a 0 8 sec pulse and then send a 15 sec pulse when locking the doors When selecting 0 8 sec 15 sec for cars with total closure the windows will be closed automatically during remote arming without enabling feature 14 When set as 0 8 sec 40 sec The system will send a 0 8 sec pulse and then send a 40 sec pulse when locking the doors When selecting 0 8 sec 40 sec for cars with total closure the windows will be closed automatically during remote arming without enabling feature 14 When set as 15 sec The system will send a 15 sec pulse when locking the doors When selecting 15 sec for cars with total closure the windows will be closed automatically during remote arming without enabling feature 14 When set as 40 sec The system will send a 40 sec pulse when locking the doors When selecting 40 sec for cars with total closure the windows will b
9. e closed automatically during remote arming without enabling feature 14 06 Door Unlock Time default 0 8 sec When set as 0 8 sec The system will send a 0 8 sec pulse when unlocking the doors When set as 3 6 sec The system will send a 3 6 sec when unlocking the doors When set as 0 8 sec 2 The system will send two 0 8 sec pulses when unlocking the doors 07 Door Unlock with Disarming default driver When set as Driver Only the drivers door will be unlocked when pressing button 2 to disarm the system Pressing button 2 again within 3 seconds will unlock the rest of the doors When set as All All the doors will be unlocked when pressing button 2 to disarm the system 08 Siren Horn Output default siren When set as Siren Select the Siren option when connecting an external siren When set as Horn Select the Horn option when connecting the output to the cars horn Note a relay must be used 09 Alarm Condition Cycle Duration default 30 sec When set as 30 sec or 60 sec The siren will sound for 30 sec or 60 sec when the system is triggered and released The siren will sound for 30 sec or 60sec x 3 cycles if the system is triggered continuously 10 Interior Light Delay default disable 5 sec When set as Disable 5 sec The siren chirps 3 times and the hazard lights flash 3 times immediately if any of the doors boot or bonnet are not closed properly when remote arming the system The releva
10. ivated as follows With the system disarmed and the ignition on Press button 1 for 2 sec to activate the anti hijacking and the hazard lights flash once to confirm The anti hijacking countdown will start depending on the selection of feature 17 The LED will flash every 2 secs once the countdown starts After 30 or 60 sec depending on the selection of feature 16 the system enters the Anti hijacking mode 10 sec before the countdown ends the siren and hazard lights will activate as a warning When the system is in anti hijacking mode the siren will sound and hazard lights flash until the system is overridden using the emergency override procedure 19 Anti hijacking by Ignition Door default disable When set as Enable The Anti hijacking will be activated as follows With the system disarmed and the ignition on Opening and closing a door will activate the anti hijacking and the hazard lights will flash once to confirm The anti hijacking countdown will start depending on the selection of feature 17 The LED will flash every 2 secs once the countdown starts After 30 or 60 sec depending on the selection of feature 16 the system enters the Anti hijacking mode 10 sec before the countdown ends the siren and hazard lights will activate as a warning When the system is in anti hijacking mode the siren will sound and hazard lights flash until the system is overridden using the emergency override procedure
11. lt Boot Bonnet trigger input Pink Remote starter module output 500mA W4 Plug in LED indicator W5 Plug in Valet switch _ auxiliary sensor 1st stage input Auxiliary sensor 2nd stage input Black Ground Red 12v Shock sensor 1st stage input Shock sensor 2nd stage input W7 3 Black Ground ________w7 4 Red 12v Door lock nc Door lock com Door lock no Door unlock nc Door unlock com W8 6 Orange Door unlock no 4 Wiring Notes Wiring Diagrams Interior Light Horn amp Boot Release Postive Interior Light Negative Interior Light To Positive To Negative Interior Light Interior Light 87 87 86 85 86 85 White es White ee 12 W3 6 87a W3 6 87a 30 30 12 Positive Horn Honk Negative Horn Honk To Positive To Negative Horn Wire Horn Wire 87 87 86 85 86 85 Brown sm Brown en W2 6 Bn W2 6 87a rs 30 30 12 i Boot Release Wiring To Boot Release Solenoid 86 ee 8 Gra gt To Fused Wa3 87a Battery Source 5 Central Locking Wiring Wiring Diagram Predator XL3 Door Lock Unlock Basic Follow the diagrams below for wiring basic central locking systems Diagram A Negative or Positive Locking Two wires resting open circuit one pulses 12V or ground for lock one pulses 12V or ground for unlock DUIT 1070W Original Built in Controller To 12V or Gr
12. nt input will be bypassed until the door boot bonnet is closed When set as 25 40 60 sec The siren chirps 3 times and hazard lights flash 3 times immediately when remote arming the system if the boot or bonnet are not closed properly The boot amp bonnet will be bypassed until both are closed properly The siren chirps 3 times and hazard lights flash 3 times in 25sec or 40 60sec after remote arming the system if the doors are not all closed properly The doors will be bypassed until they are all closed properly 11 Auto Rearming default disable When set as Enable The system will arm itself again automatically 30 seconds after disarming the system if no doors are opened Opening a door after disarming the system will deactivate the auto rearming feature 12 AED Auto Engine Disable default disable When as Enable After parking the car turning the ignition off and opening and then closing the door the engine disable relay will activate within 10 seconds but the system will still be disarmed The 10 sec countdown will be interrupted immediately when opening a door the countdown will restart when the door is closed Pressing the remote to arm the system during the 10 sec countdown will activate the AED immediately To deactivate the AED a With the system disarmed remote arming the system then disarming will deactivate the AED at the same time b With the system armed remote disarming the system will deactivate the AE
13. ound Depending on polarity of locking system Diagram C Central locking where only a switch is installed in the drivers door An additional door motor is required Diagram B Motor Interrupt Locking eg CHRYSLER Two wires resting at ground one pulses 12V for lock one pulses 12V for unlock Door Lock Switch On the Front Door Diagram D Vacuum central locking eg MERCEDES AUDI Note Set door lock unlock time to 3 6 sec Polarity Reverses on a single wire P Electric Motor Main Line Switch Down Jossoidwoy Jiy LT Wiring Diagram Predator XL3 Two Stage Door Unlock The Predator XL3 has a dedicated unlock 2 output allowing for two stage door unlock operation Two Stage Negative Trigger LOCK DOOR LOCK WIRE Black Mey Be DOOR UNLOCK WIRE UL DOOR LOCK Pink SWITCH PASSENGER DOOR MOTORS DRIVERS DOOR MOTOR FACTORY DOOR LOCK MODULE UNLOCK 4 7 12V Two Stage Positive Trigger LOCK DOOR LOCK WIRE DOOR UNLOCK WIRE UL DOOR LOCK SWITCH PASSENGER DOOR MOTORS 4 DRIVERS DOOR MOTOR FACTORY DOOR LOCK MODULE UNLOCK White a 12V Wiring Diagram Predator XL3 Two Stage Door Unlock Passenger Door Motors Two Stage Adding Actuators 1030W JOOQ SAQ UNLOCK Unlock 2
14. remote to disarm the system during the 15 sec or 30 40 will deactivate the CH3 output immediately 15 Disarm with Boot Release default disable When set as Disable When operating the remote boot release the system will remain armed but the shock sensor will be bypassed The boot will be protected and shock sensor reactivated 3 sec after closing the boot When set as Enable The system will be disarmed when operating the boot release the siren will chirp twice and hazard lights flash twice to confirm The countdown of Auto Rearming or Passive Arming will be interrupted when operating the boot release The remote boot release will still work with the ignition on 16 Anti hijacking Countdown default 30sec When set as 30 or 60 sec The system will enter the Anti hijacking mode after 30 or 60 sec depending on the selection The siren will chirp 10 times before entering into the anti hijacking mode as a last warning 17 Activate Anti hijacking Countdown default normal When set as Normal The countdown will start immediately when activating the anti hijacking feature When set as Brake The system will enter the Anti hijacking mode after the footbrake is tapped After the system starts the countdown press the valet switch before the last 10 chirps warning to stop the countdown and deactivate the anti hijacking 18 Anti hijacking by Remotes default disable When set as Enable The Anti hijacking will be act
15. sec later the siren will chirp 5 times to confirm Press button 1 of the remote control 6 times to select 15 sec and the siren will chirp 6 times to confirm the setting Press the valet switch again from 1 to 21 within 10 sec to select the next feature for programming The system will leave the programming mode and the siren will sound for 2 sec to confirm if the ignition is turned off at any time during programming or if the valet switch or remote control button 1 has not been pressed within 10 sec 1 8 Optional Programmable Features No Chirp Function 2 Chirp 3 Chirp Brake All 3 0 8 2 9 9 chirp Alarm Condition Cycle Duration Auto Engine Disable AED Disarm with Boot Release Anti hijacking by Remotes Disable Enable Flash 2 1 21 21 chirp Hazard lights Output i _ Continuou Factory Default 1 Chirp 1 9 Feature 20 Override Code default 1 flash Follow the steps below to program Turn the ignition on then off with the system disarmed Within 10 sec press the valet switch 3 times The system enters the programming mode and the siren and LED will be on for 2 sec to confirm Within 10 seconds press the valet switch 20 times to select feature 20 1 sec later the siren will chirp 20 times to confirm the selection The LED will start to flash 10 times slowly 2 sec later Press button 1 of remotes after the LED has flashed the number of times you want to set the code to Eg

Download Pdf Manuals

image

Related Search

Related Contents

SBS PI2264 mobile device charger  仕様・寸法  Ê BABYPHONE Gebrauchsanweisung .............................. „2-16  Manual de Apoio ao Usuário - TCE-RO  FCS-23A - 神港テクノス  Manual de instalación y mantenimiento Válvula refrigerante    安全に使用していただくために… 3 ゲームの遊びかた ポケモン  STERLING 72260100-96 Installation Guide  KVM Over the NET™ KN1108v / KN1116v  