Home

speed dome operating manual

image

Contents

1. PRIVACY MASK PTZ SPEED SET ZERO POWER UP MENU PASSWORD MENU IDLE 1MIN PTZ AUTO STOP 158 SELF DIAGNOSIS CORRECTION OFF BACK EXIT 24 e PRIVACY MASK Here you can set the privacy mask number and etc It includes the third menu Please move the cursor to the current item and then click the confirm button to go to the next interface e PTZ SPEED It is to set PTZ speed Please use the left right button to set e SET ZERO lt is to set the PTZ initial position Please move the PTZ to the corresponding position and then click the confirm button to complete the setup e POWER UP It is to set the PTZ action when the speed dome boots up Click the confirm button to go to the next interface To set e MENU PASSWORD It is to set the password to go to the PTZ menu Click the confirm button to go to the next interface To set e MENU IDLE If current setup is ON once you open the menu and leave it idle for specified period the menu may automatically disappear If current setup is OFF the menu is always there and will not disappear Please use the left right button to set e PTZ AUTO STOP The speed dome will stop all the PTZ operations when there is no command for the specified time It includes various setups Please use the left right button to set e SELF DIAGNOSIS CORRECTION It is to set speed dome self diagnosis correction click left right button to set ON OFF e BACK Go back to the previous menu e EXIT
2. Log out the system menu Privacy Mask Move the cursor to PRIVACY MASK and click confirm button system goes to privacy mask setup interface PRIVACY NO RESIZE PRIVACY MASKING SAVE SETTING BACK BACK Note e For security reasons please set privacy zone a little bit larger than the privacy object size e Each time after modifications you need to move the cursor to SAVE button and then click confirm button to get all setup activated Otherwise privacy zone may not move correspondingly with the object Please enter privacy mask menu Move the cursor to PRIVACY NO please use left right key to set different privacy zones For example shift to 001 section and then move the cursor to SETTING Secondly click OK button to go to the setup interface Now there is a privacy zone in the screen centre Operate PTZ to move the camera screen so that the centre of the object you want to shield is overlaying with the centre of the screen Thirdly move the cursor to RESIZE and then click left and right key to adjust privacy zone direction and size Fourthly move the cursor to SAVE and then click confirm button to exit Please note you need to click SAVE button to save current privacy mask setup so that the privacy mask region can move along with the PTZ movement to always cover the object you want to shield e PRIVACY NO Here is to set privacy mask zone Please use the left right button on the keyboard or in the speed dome terminal me
3. PICTURE FLIP FREEZE FUNCTION STABLE CAMERA FACTORY DEFAULT SETUP and CAMERA RESTART Please use the left right button on the keyboard or in the speed dome terminal menu to set APERTURE It is to adjust the lens to achieve clear video Please use the left right button on the keyboard or in the speed dome terminal menu to set APERTURE RESTRAIN System can auto reduce the aperture to lower the video noise when it is in low illumination environment Please use the left right button on the keyboard or in the speed dome terminal menu to set DIGITAL ZOOM Click left right button to set on off DIGITAL ZOOM LIMIT Set the upper limit of digital zoom of the camera PICTURE FLIP Click left right button to set on off FREEZE FUNC Click left right button to set on off STABLE Click left right button to set on off NEXT PAGE It includes camera factory default camera restart function setting item Move the cursor to this item click OK button to display all the other function setting item of the camera 13 e CAMERA FACTORY DEFAULT move the cursor to the item click OK button to restore camera factory default CAMERA RESTART move the cursor to the item click OK button to restart the camera e BACK Go back to previous menu e EXIT Log out system menu 4 4 3 1 White Balance Setup WB MODE R GAIN B GAIN BACK Move the cursor to WHITE B
4. Please use the left right button on the keyboard or in the speed dome terminal menu to set TIME DISP Display dome system time or not Please use the left right button on the keyboard or in the speed dome terminal menu to set POSITION Display the angel between the benchmark and then current location Please use the left right button on the keyboard or in the speed dome terminal menu to set e ZOOM DISP Display speed dome optical zoom speed or not e INSIDE TEMPERATURE Display dome internal temperature or not There are three options C F Off Please use the left right button on the keyboard or in the speed dome terminal menu to set TITLE DISPLAY Here you can set to display speed dome position information and etc You can use the speed dome control terminal to set the detailed title information Please use the left right button to set e RS485 DETECT It will display wrong messy code when users control the speed dome in a situation where RS485 connection is wrong The function can be used to set if it will display the wrong code BACK Go back to the previous menu e EXIT Log out system menu 4 4 3 Camera Setting Before the operation please make sure your camera supports the corresponding function 12 WB SE CAMERA FACTORY DEFAULT EXPOSURE SE TTING APERTUBE RESTRAIN DAY NIGHT SETTING DIGITAL ZOOM CAMERA RESTART RORIS SETING B PON LIMIT MAGE ADJUST PICTUR BACK EXIT FREEZE PING STABLE NEXT PAGE Move the cursor to
5. SAVE BACK e PASSWORD Enable this function here so that you set password is valid This function is on by default after you set password e SETTING Click the confirm button to go to the password setup interface Please use the left right button to set the value and then click the confirm button to confirm current option Move the cursor to the SAVE button and then click the confirm button to save current setup Click the BACK button to go to the previous menu e BACK Go back to the previous menu e EXIT Log out the system menu If you have forgot your password After three times of login failure system may pop up an 8 digit internal code Please contact our technical engineer for help 4 4 5 Wiper Setting Move the cursor to Wiper Setting button and then click confirm button You can go to the wiper setting menu of the speed dome WIPER MODE MANUAL START TIME 07H 00M END TIME 19H 00M INTERVAL 01S WIPER CONTROL STOP SAVE BACK EXIT e WIPER MODE It is to set the wiper mode It includes two modes manual and schedule click left right button to set e START TIME It is to set the wiper start time click left right button to set Note It is valid only when the wiper mode is set as schedule mode e END TIME it is to set the wiper end time click left right button to set Note it is valid only when the wiper mode is set as schedule mode e INTERVAL it is to set the interval
6. UP MENU PASSWORD MENU IDEL and PTZ AUTO STOP ETC Move the cursor to the item and then click the confirm button to display other function settings PRIVACY MASKING It is to set the speed dome privacy masking including level three menu move the cursor to the item click confirm button to go to next menu PTZ SPPED It is to set PTZ speed click left right button to set SET ZERO After PTZ moves to the zero location which is to be set then click OK button to complete setting POWER UP It is to set speed dome power up click OK to go to next menu to set MENU PASSWORD It is to set the speed dome menu password click OK to go to next menu to set MENU IDLE TIME The menu is on and the setting of the item is not OFF then it will exit menu automatically if there isn t any operation to the menu during the set time OFF means it displays speed dome menu all the time Click left right button to set PTZ AUTO STOP When the speed dome didn t receive control command to the PTZ it will stop PTZ operation automatically when it reaches the set time including several setting items Click left right button to set SELF DIAGNOSIS ADJUST It is to set speed dome self diagnosis correction click left right button to set on off it is valid after soeed dome reboots BACK Move the cursor to the item click OK to go back to previous menu EXIT Log out system
7. Windows Internet Explorer E about We de SolenkPage Input your IP address here Internet 4 100 Figure 3 1 System pops up warning information to ask you whether install control webrec cab or not Please click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the plug in to disable the control download Or you can lower the IE security level See Figure 3 2 Internet Options X Security Settings Internet Zone General Security Privacy Content Connections Programs Advanced Settings O Disable Select a zone to view or change security settings Enable a 9 Download signed Activex controls not secure amp Y T O Disable Internet Local intranet Trusted sites Y Enable not secure a j E Prompt recommended Internet ae 9 Download unsigned ActiveX controls not secure This zone is for Internet websites aes Disable recommended except those listed in trusted and Enable not secure restricted zones re nae Initialize and script Activex controls not marked as safe For s Disable recommended Enable not secure Security level For this zone Allowed levels For this zone Medium to High Medium high O Prompt y p Appropriate for most websites a A P Te Prompts b
8. between the two actions for the wiper click left right button to set WIPER CONTROL It is to set the wiper action it can set start stop once Click left right button to set Note It is valid only when the wiper mode is set as manual mode e SAVE It is to save the setting BACK Go back to the previous menu e EXIT Log out the system menu 4 4 6 Laser Setting LASER SETTING RULE ZOOM PRIORITY ANGLE INTENSITY BACK Move the cursor to the LASER SETTING button and then click confirm button to set LASER SETTING RULE It is to set the laser setting rule there are two options zoom priority and manual Click left right button to set e ANGLE It is to set the laser angle click left right button to set Note It is valid only when laser setting rule is set as manual mode INTENSITY it is to set the laser intensity click left right button to set Note It is valid only when the laser setting rule is set as manual mode BACK Go back to the previous menu e EXIT Log out the system menu 4 5 Abnormity Handling If users hope to restore the speed dome to factory default please enter the main menu of the speed dome SYSTEM INFORMATION gt FACTORY DEFAULT move cursor to FACTORY DEFAULT and click confirm button The speed dome will reboot and all the setups restore to factory default setup 27 5 Cable Connection 5 1 Combination Cable Connection T
9. control keyboard matrix or speed dome control terminal SYSTEM SETTING DISPLAY SETTING CAMERA SETTING FUNCTION SETTING WIPER SETTING LASER SETTING EXIT e SYSTEM SETTING Display speed dome system information address information Here you can set north direction language factory default setup reboot and so on e DISPLAY SETTING Display dome preset title azimuth display time direction dome internal temperature title information zoom information and etc e CAMERA SETTINGS Set dome white balance camera parameter day night setup and etc e FUNCTION SETTING Set preset pan auto scan auto tour pattern idle function time task and privacy mask function e WIPER SETTING Set wiper mode start time stop time interval time wiper control and etc 10 e LASER SETTING Set laser control rule angle intensity and etc e EXIT Log out the system menu 4 4 Menu Operation In the speed dome main menu you can use the left right button on the keyboard or in the speed dome terminal menu to configure the system menu Before setup please move the cursor to the current item you want to configure e In main menu please click confirm button to go to the sub menu or use left right key to configure setup e Use up down button to select back option and then click confirm button to go back to the previous menu e Use up down button to select exit option and then click confirm button to log out system menu e All setup here will no
10. device You can use the dry cloth with some alcohol or mild detergent to clear if necessary e Do not use the volatility solvent such as the benzene or thinner or detergent with strong abradibility It may result in lens damage or it may adversely affect the device performance O If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device 8 About Accessories Always use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if something is missing in your package 1 Features and Functions 1 1 General Introduction This series laser HD speed dome product is an integrated high intelligent speed dome lt adopts new configuration design and is easy for the project construction This is a digital and intelligent product of vivid video The installation is convenient Comparing with the previous series product this series laser HD speed dome has added some new features It supports intelligent analysis function and the PTZ rotation speed can automatically adjust according to the zoom rate of the lens It supports various languages real time clock function and protocol auto recognition It supports 360 continuously pan 110 tilt 20 90 and 180 auto flip It can realize no blind spot monitor 1 2 Feature
11. menu 4 4 4 1 Preset Setup PRESET NO 1 TITLE PRESET 1 SETTING CALL BACK Move the cursor to PRESET button and then click confirm button to go to set interface PRESET NO Please use left right key to modify preset number The different protocols support different preset values TITLE Title text is the label used for you to identify the camera System will automatically name a title for the camera SETTING Please input preset number first and then select the monitor zone Please move the cursor to setting and click confirm button The system will pop up a message PRESET Here means preset number And the SETTING column pops up an OK Now you successfully added a preset Please note you need to enable display preset title function first Main menu gt display setting gt preset title Repeat the above procedures to set more presets Once you want to modify a preset you can input the preset number you want to modify and then follow the above steps to set the preset You can successfully modify a preset content CALL Here is to recall preset Move the cursor to PRESET NO and then input corresponding preset value Then move the cursor to CALL and then click confirm button to go to a preset BACK Go back to previous menu EXIT Log out system menu For PELCO protocol user please refer to the following special functions e Call preset Call preset 28 or preset 95 to go to dome menu Call preset 29 or preset 99 to go
12. move the cursor to the SAVE button to save current setup e END TIME Here you can set the task end time Move the cursor to current item and then click confirm button to set the time Please use the up down button to set the detail value and then use left right button to go to the next setup item After you completed the setup please click confirm button to exit end time setup and then move the cursor to the SAVE button to save current setup e ACTION TYPE The option here includes tour scan preset pattern and etc Please use left right button to set e ACTION NO It is the corresponding serial number of the schedule task The number here may vary due to different action types e SAVE After the above setting are done move the cursor to SAVE and click OK button to save all the setting information e BACK Go back to the previous menu e EXIT Log out the system menu Task Information Move the cursor to the TASK INFORMATION and then click the confirm button to go to the following interface Here you can see the corresponding task information Click the confirm button again you can exit current interface TIME ACTION 00 00 00 SC001 00 00 00 SC001 00 00 00 SC001 00 00 00 SC001 00 00 00 SC001 00 00 00 SC001 00 00 00 SC001 4 4 4 8 Next Page Move the cursor to the NEXT PAGE and then click the confirm button you can go to the third menu to set the PTZ SPEED SET ZERO POWER UP and etc
13. specified time The exposure value does not resume if this function is off WDR SETTING It is an abbreviation for wide dynamic region Please make sure your camera supports current function This function can adjust the video brightness when the contrast between the strong light and the dark light is too high There is the fourth menu Please move the light to highlight current item and then click the OK button to go to the next level menu e BACK Go back to previous menu e EXIT Log out system menu 4 4 3 3 WDR Move the cursor to WDR and then click confirm button you can go to the 4 layer menu to set corresponding parameters WDR MODE OFF DETECTION SENS LOW SHADOW CORRECTION MID MOVEMENT COMP OFF BACK EXIT WDR MODE It is to enable or disable WDR function Please use the left right button on the keyboard or in the speed dome terminal menu to set 15 e DETECTION SENSISIVITY It is to set WDR detection sensitivity Please use the left right button on the keyboard or in the speed dome terminal menu to set e SHADOW CORRECTION It is to set video shadow correction level Please use the left right button on the keyboard or in the speed dome terminal menu to set O MOVEMENT COMPENSATION it is to set the camera movement compensation click the left and right direction on the keyboard or the left and right button on the terminal menu to set on off e BACK Move the cursor to the item click OK button to go bac
14. the specified time There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to set TASK SETTING Here you can set task time operation operation SN and etc Please click the confirm button to go to the fourth menu to set TASK INFORMATION Here you can view the corresponding task information Please click the confirm button to go to the fourth menu to set DELETE TASK Please input the task number to be deleted in the TASK NO and then move the cursor to the current item Click the confirm button you can remove all the setups in the current schedule task Now current task is null BACK Go back to the previous menu EXIT Log out the system menu Task Setting Move the cursor to the TASK SETTING and then click the confirm button you can set the task begin time end time action type and etc WEEK ALLWEEK START TIME 00H 00M END TIME 00H 00M ACTION TYPE SCAN ACTION SN 11 SAVE BACK EXIT e WEEK Here you can set the week information Please use the left right button to set You can set for one day or you can set for the whole week e START TIME Here you can set the task begin time Move the cursor to current item and then click confirm button to set the time Please use the up down button to set the detailed value and then use left right button to go to the next setup item After you completed the setup please click confirm button to exit start time setup and then
15. 1 Network CONOCIO usina diana 3 2 LOGIN ANd LOGOUtis 0 0 scccecsseusnseniersvecesensesensoevnssssenssdesiessnecnsocnoessesdesendenbudescentesensertassacseceesstenseduatestesevsentnsmnsesscesssentiss 4 1 Screen Menu INdeX ciiooiooconoocoooooinioncaonosicinonins cossscvocessusansespsossavesuees codensavsoasvees usscvosenesgase cdavesescesavenadsosovesdeesseeecoes 9 4 2 Self diagnosis System Information ssssssssssscssssssssssesessssessssssesecsssessssesesecsssessseesesecsssesecsesesesessessseeseseceeseses 10 4 3 Main E AAA PPP ONO 10 4 4 Menu OPOratio nn E EREET E E S AEE S 11 4 4 1 System nfOrmations senn a i Gen dele E adhe a hei a ee 11 44 2 Display Setting iii ri 12 AMS Camera Sl td a eo Ten le e en el 12 44 4 FUNCION Sl cit dba 18 E ES A hake caeh tiene 26 4 4 6 A chee ARI RR ee ee ee ES 27 4 5 Abnormity FANNING eisses raain eii ENIE 27 5 CABLE CONNECTION ariadna aida AAA AEREA AAA AAA 28 5 1 Combination Cable ConnectioN oooooommmmmmmmmssmmmmmmmrrmmmmmmmmmmrrrrrrrre 28 5 2 System La yO Ub cscseiscssvssdessscsessdesssscssicessecestehcesacceusscestescssnscesdecaadehdecbsceusssassaszosasdacsacaatabdosacdecsdcasdastesaasesdbcandastesaasecsecs 29 5 21 ES E ele eel aces ela eee a eel 29 5 2 2 Alarm CONNECTION 2 0 EEE A E E EE A EO AEE E E EE AE 29 E PAN ahaa cas cians cactus panes aysiu sauyciutsanyciuk sansciusaansciuksausciussaueciuksauuciutaanuciusaanyciuneauneneeaaananetans 30 6 1 Daily Maintenance sesoonse i
16. ALANCE MODE and then click confirm button you can go to the submenu e WHITE BALANCE MODE Set white balance adjustment mode There are several modes such as auto auto trace white balance indoor outdoor and manual and etc Please use the left right button on the keyboard or in the speed dome terminal menu to set e R GAIN Before you set R GAIN option please note the mode shall not be auto Please use the left right button on the keyboard or in the speed dome terminal menu to set e B GAIN Before you set B GAIN option please note the mode shall not be auto Please use the left right button on the keyboard or in the speed dome terminal menu to set e BACK Go back to previous menu e EXIT Log out system menu 4 4 3 2 Exposure Setting AE MODE SLOW SHUTTER ON BRIGHTNESS RESTRAIN 50 GAIN SETTING 2 AUTO SLOW SHUTTER AE RECOVERY 15Min SHUTTER SETTING LIMIT WDR SETTING IRIS SETTING AGC GAIN LIMIT 3 BACK EXIT EXPOSURE COMP HIGH GAIN SLOW AE 1 NOISE REDUCTION BLC 3D NOISE REDUCTION NEXT PAGE EXPOSURE RESTRAIN BACK NEXT PAGE BACK e AE MODE Here you can set the camera exposure mode It includes auto manual iris priority shutter priority Auto The gain iris and shutter is under auto setup mode Manual You need to set gain iris and shutter manually Iris priority You can set iris manually Gain and shutter is under auto setup mode Shutter priority You can set shutter manually Gain and iris is under au
17. CAMERA SETTING and then click confirm button you can go to the submenu WHITE BALANCE SETUP Move the cursor to current option and then click confirm button you can go to the third menu EXPOSURE SETTING Move the cursor to current option and then click confirm button you can go to the third menu DAY NIGHT Set day night mode Move the cursor to current option and then click confirm button you can go to the third menu There are three options auto manual off Please use the left right button on the keyboard or in the speed dome terminal menu to set Please make sure your product supports this function FOCUS SETUP It is to set the camera focus mode focus limit and etc Please move the light to highlight current item and then click the OK button to go to the next level menu IMAGE ADJUSTMENT It is to set the camera hue saturation color control gamma and etc There is the third menu Please move the light to highlight current item and then click the OK button to go to the next level menu DEFOG It is to set camera defog mode and intensity lt can enhance the camera video quality under the fog environment There is the third menu Please move the light to highlight current item and then click the OK button to go to the next level menu ZOOM SPEED The bigger the value the faster the speed Please use the left right button on the keyboard or in the speed dome terminal menu to set NEXT PAGE It includes the following options DIGITAL ZOOM
18. Click confirm button you can exit the setup After you completed the setup move the cursor to back button to go to the previous interface e DELETE TOUR Here is to delete a tour Input tour number in TOUR NO and then move the cursor to DELETE TOUR click confirm button to delete e CALL Here is to activate tour Input tour number in tour NO and highlight CALL click confirm button to activate touring e STOP Here is to terminate touring BACK Go back to previous menu e EXIT Log out system menu 4 4 4 5 Auto Pattern PATTERN NO PROGRAM START PROGRAM STOP CALL STOP BACK Pattern function can memory PTZ operation and camera focus zoom in and zoom out From the start position dome begins auto movement repeatedly Move the cursor to PATTERN and click confirm button PATTERNNO Here is to set pattern number Please click left right key to configure PROGRAM START Here is to memorize pattern starting point An icon OK pops up in screen to prompt you system begins memory pattern PROGRAM STOP Here is to set pattern stop point After all the movement move the cursor to PROGRAM STOP and then click confirm button Now you have set one pattern System pops up an icon OK to prompt you system has memories one pattern e CALL Here is to activate pattern Input pattern number move the cursor to CALL and click confirm button system begins running pattern STOP Here is to stop current pattern Input pattern number move t
19. HD Laser Speed Dome User s Manual Version 1 0 0 Table of Contents 1 FEATURES AND FUNCTION Sisi 1 1 General IntrOdUCtiON disse ccscescs ss cssscesievedssaccesscecccsaesecs soesen sdevesceavassecoseauaace se coauuesdeveden cian ssceceuvadcesdeutsecsbevesueadevsesocassessocbansc 1 2 A NN 12 OMS feen Mel coo data tidad 12 2 LIO LIMM x 3 he o a eee aden ail a ee onde 1 2 3 OSD EE E SE A AS 1 2 4 Preset Setup And AA 12 5 PAULO Nito 1 2 6 Auto TOUNO Aeran ns ama died iban dias ima diia ia iaa dais 12 7 Auto m 10 gt Ve d 1 2 8 Privacy Mask cid ia A A NN 1 2 10 SOMA ei 2 2 siseatiede eles Sud a Rite easiest Red ete asd nie eas ees 1 2 11 Day Night Mode B W amp Color Mode ccccceecessssesescsesestsceseecscsesaescseecseneataceesecaenasaeaceesecaenanacaceetecaeneeaeas 1 2 12 AUTO FOCUS r atada 1 2 13 Backlight Compensation seenen a a a A A A E E E E 1 2 14 Pan TN AMG Zo Mica sia a adi aia di dic 1 2 15 3D Intelligent Positioning o 563 c s0see csesesccssavesuendescsecvavseescnsotebschcubebuensosebeensobensensovebsebcubdbsebdobebuensobeeseneevesed sie 1 2 16 dls StatlS tas ett do Ueto das De e ote e E E tie eet eked at le 1 2 17 Image StabiliIZer Fup vic cidade iia 2 QUICK CONFIGURATION POO Litas 3 2 1 A NR OA NA 2 2 A A soesusudsauseusescevonsesuevavessoeteadesassoeer 3 WEB OPERATION 0 2cccecceecceeceeceeccneceecenecneceascneceescnscnecenscusceasenseusscnscusceaseuseussensensecusensens 6 3
20. O RUN NEXT PAGE BACK EXIT WIPER SETTING WIPER MODE START TIME STOP TIME INTERVAL WIPER CONTROL SAVE BACK EXIT LASER SETTING LASER CONTROL RULE ANGLE INTENSITY BACK EXIT EXIT Address 1 S Baud rate 9600 Parity None Software Version 2 02 14 RHIRFZ The above diagram illustrates the overall structure of the speed dome setup menu Note ERRmeans current setup is invalid Please make sure all the cable connections are right 4 2 Self diagnosis System Information ADDR 1 S BAUD RATE 9600 PARITY NONE SOFTWARE V1 02 0 R BACK EXIT After installation please connect speed dome to power The system goes on a self diagnosis and then it pops up the above interface to show the system information The above interface disappears after speed dome received the first command or the display time lasts for 20 seconds e ADDR Here you can view dome address information For example 1 S 1 is the address number S is software address mode e Baud rate Dome communication baud rate e Parity Communication parity bit format e Software Dome PTZ software version When you are using the control keyboard or the matrix host to control the device please make sure the control parameter of the keyboard or the matrix host is the same with the speed dome OSD including address baud rate parity Please make sure the cable connection is OK 4 3 Main Menu You can open the IP dome menu via
21. area that cannot be viewed by you The masking area will move with pan and tilt functions and automatically adjust in size as the lens zooms 1 2 9 Auto Flip As long as you continue to hold the keyboard joystick in the down position the dome rotates 180 degrees and repositions itself for uninterrupted viewing of any subjects that passes directly beneath the dome 1 2 10 Self diagnosis There is a self diagnosis procedure when dome boots up e Tilt and vertical engine check e Camera diagnostics mainly zoom function diagnosis Display dome information 1 2 11 Day Night Mode B W amp Color Mode Auto manual switches in low illumination There are several modes such as photoresistor auto manual and etc This function needs the speed dome driver camera supported 1 2 12 Auto Focus Support camera auto focus function 1 2 13 Backlight Compensation Balance the brightest and darkest sections of a scene to produce a more vivid picture 1 2 14 Pan Tilt and Zoom Supports zoom in and zoom out during tilt and pan movement You can still get vivid image even you set auto focus and auto iris during this period 1 2 15 3D Intelligent Positioning Support 3D intelligent positioning function The speed dome can auto track to the specified zone 1 2 16 Idle Status When there is no available order for specified duration you can use menu to set dome idle status 1 2 17 Image Stabilizer Flip You can enable image stabilizer function and flip in the menu When t
22. d to move the cursor here and then click confirm button to save current time setup For other setups you do not need to use this button BACK Go back to previous menu EXIT Log out system menu 4 4 3 5 Focus Setup FOCUS MODE AUTO FOCUS LIMIT 10CM FOCUS SENSITIVITY FAULT ZOOM TRACKING OFF LASER FOCUS CORRECTION AUTO BACK EXIT 16 FOCUS MODE It is to set the camera focus mode It includes several modes such as auto manual semiautomatic FOCUS LIMIT It is to set the camera focus limit Please use the left right button on the keyboard or in the speed dome terminal menu to set FOCUS SENSITIVITY It is to set the camera focus sensitivity Please use the left right button on the keyboard or in the speed dome terminal menu to set ZOOM TRACKING it is to set the camera zoom tracking click the left right button on the keyboard or in the speed dome terminal menu to set LASER FOCUS CORRECTION It is to set the camera laser focus correction Please use the left right button on the keyboard or in the speed dome terminal menu to set BACK Go back to previous menu EXIT Log out system menu 4 4 3 6 Image Adjust Move the cursor to IMAGE ADJUST and then click confirm button to go to the level 3 menu to set HUE BRIGHTNESS SATURATION CHROMA SUPPRESS GAMMA CONTRAST IMAGE STYLE BACK e HUE It is to set picture hue Please use the left right button on the keyboard or in the speed dome terminal menu to se
23. e use the left right button on the keyboard or in the speed dome terminal menu to set e LIGHT INTENSITY LEVEL It is to set air light intensity value It is valid when the air light intensity mode is manual Please use the left right button on the keyboard or in the speed dome terminal menu to set BACK Go back to previous menu e EXIT Log out system menu 4 4 3 8 Next Page Setting Move the cursor to NEXT PAGE and then click confirm button you can go to the level 3 menu to set corresponding parameters APERTURE SETTING CAMERA FACTORY DEFAULT APERTURE RESTRAIN LEVEL CAMERA RESTART BACK EXIT NEXT PAGE BACK e APERTURE Itis to adjust the lens to achieve clear video Please use the left right button on the keyboard or in the speed dome terminal menu to set e APERTURE RESTRAIN System can auto reduce the aperture to lower the video noise when it is in low illumination environment DIGITAL ZOOM You can use the left right button to enable disable the digital zoom function e DZOOM LIMIT Here you can set the threshold of the digital zoom PICTURE FLIP There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to set e FREEZE FUNCTION This function allows the system from one preset to another preset without showing the video during the PTZ movement There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to
24. ed in the configuration tool main interface is shown as below See Figure 2 5 NetWork Parameter PPPOE System Informati onl System Upgrade General Parameter DHCP Enable rv x IP Address 192 168 1108 O00 Subnet Mask 255 255 255 0 Gateway s2a6811 Mac Address p0 02 a9 00 76 83 Save Return Figure 2 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD 3 Web Operation This series speed dome product supports the Web access and management via PC Web includes several modules live view PTZ setup alarm logout and etc Speed dome factory default setup e P address 192 168 1 108 e Username admin e Password admin 3 1 Network Connection Please follow the steps listed below for network connection e Make sure the speed dome has connected to the network properly e Speed dome IP address and PC IP address shall be in the same network segment Speed dome default IP address is 192 168 1 108 If there is router please set the corresponding gateway and subnet mask e Use order ping speed dome address to check connection is OK or not 3 2 Login and Logout Open IE and input speed dome address in the address bar For example if your speed dome IP is 192 168 1 108 then please input http 192 168 1 108 in IE address bar See Figure 3 1 Blank Page
25. efore downloading potentially unsafe 0l Run ActiveX controls and plug ins gt content OD Adminictratay annravad Unsigned ActiveX controls will not be downloaded lt alll Takes effect after you restart Internet Explorer Default level Reset custom settings Reset tot medium high default Reset all zones to default level Figure 3 2 After installation the interface is shown as below See Figure 3 3 Please input your user name and password Default factory name is admin and password is admin Select the network connection type Note For security reasons please modify your password after you first login Figure 3 3 After you logged in you can see the main window See Figure 3 4 IP PTZ Dome Sub Stream J sub Stream2 fiaa IP PTZ Dome _ 0 SS tte PTZ Figure 3 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction 4 Menu 4 1 Screen Menu Index Note ERR means current setup is invalid you need to restores speed dome factory default setup Slight difference may be found due to different series Laser lamp is dangerous please don t look at it directly SYSTEM SYSTEM INFORMATION INFORMATION ADDR INFORMATION SET NORTH LANGUAGE FACTORY DEFAULT RESTART BACK DISPLAY SETTING CAMERA SETTING Z NEXT PAGE BACK FUNCTION SETTING PRESEI AUTO SCAN AUTO TOUR AUTO PATTERN IDLE MOTION AUT
26. he cursor to STOP and click confirm button System stops current pattern BACK Go back to previous menu e EXIT Log out system menu Note The dwell time between two orders should be less than one minute otherwise system will set to default value as one minute e After click PROGRAM STOP do not click CALL button before icon disappears completely Any manual operation during the pattern procedure will terminate current dome pattern operation 4 4 4 6 Idle Function 22 IDLE ACTION IDLE TIME ACTION TYPE SN BACK Move the cursor to IDLE ACTION and click OK button to set the idle action of the speed dome IDLE ACTION The speed dome will execute the preset action if it didn t receive any valid command during set time IDLE TIME It is to set idle time click left right button to set ACTION TYPE It includes none preset scan tour pattern idle actions click left set SN It is to set idle motion SN System can implement the corresponding action when it is idle for the specified period Click the left right button to set BACK Go back to previous menu right buttons to 4 4 4 7 Auto Run Schedule task TASK NO 1 TIME TASK OFF TASK SETTING TASK INFORMATION DELETE TASK BACK TASK NO Here you can set task number Please use the left right button to set TIME TASK The schedule task allows the speed dome to implement corresponding setup during
27. he speed dome combination cable includes network cable audio video cable connection port RS485 connection port alarm input and output port Please refer to the label for detailed information e Please note the IE6 does not support alarm upload function Please use IE7 or higher version e If it is your first time to boot up the WEB on the Windows 7 OS please right click the Internet Explorer icon on the desktop and then select Run as Administrator e Slight difference may be found in the port amount since some functions are optional e Recommended models of PoE switch 8 ch DH S1000 8TP 1 ch DH PFT1200 Name Function POWER Power port Connect to the power cable GND GND ground end 485A RS485 remote control 485B AUDIO OUT Audio output port GND Ground port IN Audio input port VIDEO GND Ground port OUT Video output port RJ45 Network port Connect to network cable and HI PoE ALARM IN e Seven alarm input channels It is to receive relay signal from the external alarm source You can go to dome menu to activate specified preset or patter e When the activation mode is NO normal open dome alarms when there is low voltage High voltage will not activate the alarm e When the activation mode is NC normal close dome alarms when there is high voltage Low voltage will not activate the alarm Note e Dome alarm input message is ground mode Dome alarm input signal are
28. here is vibration this IS function can guarantee video stability and when flip you can view video more clearly This function needs speed dome driver camera supported 2 Quick Configuration Tool 2 1 Overview Quick configuration tool can search current IP address modify IP address At the same time you can use it to upgrade the device Please note the tool only applies to the IP addresses in the same segment 2 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 2 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc SN IP Address Port Subnet Mask Default Gateway Mac Address 1 192 168 1 108 37777 255 255 255 0 192 168 1 1 90 02 a9 7b 50 sil Tip You can click login button directly and information to login P then input corresponding infor all y Upgrade Figure 2 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 2 2 Note You can set the IP address subnet mask and gateway for the network camera and PC Please note network camera IP address and PC IP address shall be in the same network segment if there is no router Network camera default IP address is 192 168 1 108 If there is a router please set the corresponding gateway and subnet mask The factory default user name is admin and password is admin For security
29. i i i R E R E 30 6 2 Problems and SolutionS ococonononononononcncnononononoconanacininionononononononoconcncncn coco ooononononon anar conocononononorocococrcrccorosor oros 30 7 APPENDIX LIGHTNING PROOF AND SURGE PROTECTION oocmmcccccccccccccnnncnanccccnnnnonos 31 8 APPENDIX 2 TOXIC OR HAZARDOUS MATERIALS OR ELEMENTS s sssseeeeeeeeees 32 11 Welcome Thank you for purchasing our product This user s manual is designed to be a reference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Before installation and operation please read the following safeguards and warnings carefully 111 Important Safeguards and Warnings et al Electrical safety All installation and operation here should conform to your local electrical safety codes We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation We are not liable for any problems caused by unauthorized modification or attempted repair Transportation Security No heavy stress violent vibration or water splash are allowed during transportation storage and installation Please use the original packing material or the material of the same quality when you ship it back to the manufacturer Installation Do not apply power to the product before completing i
30. ing wrong with power board Use multimeter to check dome load Please contact retailer to replace power board 2 No self diagnosis There is a noise Power supplying is inadequate Replace power supplying Mechanical malfunction Need electrical engineer help 3 Video signal is not successive Circuit connection is too loose Connect tightly Video switch or power problem Need electrical engineer help 4 Video is not clear Focus is in manual mode Control manually Dome cover is dirty Wash dome cover 5 During camera switch there is a tilt movement in the monitor Camera power is not in the same Phase When several domes are connected to one transformer please connect the transformer output cable to the domes same side 30 7 Appendix Lightning Proof and Surge Protection This series speed dome adopts TVS lighting protection technology lt can effectively prevent damages from various pulse signals below 1500W such as sudden lighting and surge While maintaining your local electrical safety code you still need to take necessary precaution measures when installing the speed dome in the outdoor environment The distance between the signal transmission cable and high voltage device or high voltage cable shall be at least 50 meters Outdoor cable layout shall go under the penthouse if possible For vast land please use sealing steel tube u
31. k to previous menu e EXIT Log out system menu 4 4 3 4 Day Night Setting Move the cursor to DAY NIGHT SETTING and then click confirm button you can go to the 3 layer menu to set corresponding parameters DAY NIGHT MODE PHOTORESISTANCE DAY NIGHT TYPE MECHANISM DAY TIME 00H 00M NIGHT TIME 00H 00M SENSITIVITY 5 SAVE BACK EXIT DAY NIGHT It is to set camera day night switch mode It includes Photosensor auto schedule color B amp W Please use the left right button on the keyboard or in the speed dome terminal menu to set DAY NIGHT TYPE It is to set the camera day night type it includes mechanism electronic Click left right button to set DAY TIME Current setup becomes valid when day night mode is Time Move the cursor to DAY TIME item and then click confirm button to go to setup Please user up down button to set the value After completed setup please click confirm button to exit and move the cursor to Save button to save current setup NIGHT TIME Current setup becomes valid when day night mode is Time Move the cursor to DAY TIME item and then click confirm button to go to setup Please user up down button to set the value After completed setup please click confirm button to exit and move the cursor to save button to save current setup SENSITIVITY It is to set the sensitivity of DAY NIGHT SAVE This button is for DAY TIME and NIGHT TIME setup After you set the day time or night time you nee
32. nder the land to implement cable layout and connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power lightning protection device or lightning rod The lightning protection and earth of the outdoor device and cable shall be considered in the building whole lightning protection and conform to your local national or industry standard System shall adopt equal potential wiring The earth device shall meet anti jamming and at the same time conforms to your local electrical safety code The earth device shall not short circuit to N neutral line of high voltage power grid or mixed with other wires When connect the system to the earth alone the earth resistance shall not be more than 4Q and earth cable cross sectional area shall below 25 mm2 See Figure 7 1 Video Lighting Rod Communication Lighting Rod Power A Lighting Rod The speed dome shall be installed within the 45 angel of the lighting rod Earth cable resistance shall be less than 40 Steel tube shield Figure 7 1 31 8 Appendix 2 Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Pb Hg Cd Cr VI PBB PBDE Sheet Metal O o O o o o Plastic Parts o o o o o o PCB o o
33. nstallation Do not put object on the product Qualification Requirement The device has to be installed and repaired by professional licensed technician and installation personnel Dismantling Don t remove screws or protection cover there are no parts inside the SD for users to repair by themselves Environment This series product should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation object and environment Please keep the sound ventilation Do not allow the water and other liquid falling into the device This series product complies with the IP66 standard specified in the Degrees of Protection Provided by Enclosure Please make sure the CCD CMOS component is out of the radiation of the laser beam device Otherwise it may result in CCD CMOS optical component damage Usually we recommend lightning proof device to prevent thunder strike The GND port of the product shall be grounded to further enhance the reliability of the device Daily Maintenance Current series product has no power button Please unplug all corresponding power cables before your begin installation or daily maintenance work Please keep the dustproof cap back to protect the CCD or CMOS part if the device does not work for a long time iv e Do not touch CCD CMOS component You can use the blower to clean the dust on the surface of the
34. nu to set You can call corresponding privacy mask zone number if you have successfully set one e PRIVACY MASKING There are two settings on and off Please go to the corresponding privacy mask zone and click left right button to set 25 e RESIZE Itis to adjust the privacy zone size Move the cursor to current item and use the left right button on the keyboard or in the speed dome terminal menu to set Please continue pressing direction button to widen or narrow zone size lt is to narrow the horizontal width and is to widen the horizontal width is to widen vertical height and is to narrow the vertical height SAVE Here is to save user setup BACK Go back to previous menu e EXIT Log out system menu Power Up Move the cursor to the POWER UP item and then click the confirm button you can go to the fourth menu POWER UP PARAMTER BACK EXIT e POWER UP It is to set the PTZ operation when the speed dome boots up The option includes NONE AUTO SCAN PRESET PATTERN TOUR and etc Please use the left right button to set e PARAMTER Here you can set the serial number of the corresponding operation such as the scan preset pattern tour Please use the left right button to set e BACK Go back to the previous menu e EXIT Log out the system menu Menu Password Move the cursor to the MENU PASSWORD and the click the confirm button to go to the fourth menu PASSWORD PASSWORD SETTING 1 2345 BACK 6 7890 gt
35. o o o o Housing o o o o o o Camera Driver O o o o o o Bearing o o o o o gt Connection 3 x 3 o lt Cable Motor O O O O Oo O If possible Power O O Oo O O O If possible Bracket R 3 o 3 e E If possible Accessories o o o o o o Note O Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes 32 Note This manual is for reference only Slight difference may be found in the user interface All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit
36. our website or contact your local service engineer for more information 33
37. reasons please modify your password after you first login For detailed WEB operation please refer to the Web Operation Manual in the resource CD Device List Sy IP Address Port Subnet Mask Default Gaten Mac Address m E ENANA pen Device Wel Tip You can click login button directly and then input corresponding information to login fa y Upgrade Refresh Login Figure 2 2 Select the Open Device Web item you can go to the corresponding web login interface See Figure 2 3 IP PTZ Dome Figure 2 3 If you want to modify the device IP address without logging in the device web interface you can go to the configuration tool main interface to set In the configuration tool search interface Figure 2 1 please select a device IP address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface See Figure 2 4 In Figure 2 4 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you can nat login the device If you are using device background upgrade port 3800 to login other setups are all invalid IP Address 192 168 1 108 User Name ko Password Port 37777 coca Figure 2 4 After you logg
38. s This series speed dome has the following features 1 2 1 On Screen Menu This series product menu supports multiple languages It is easy for you to view dome information and configure dome camera parameters 1 2 2 Zoom Speed Limit The laser HD intelligent speed Dome adopts auto match technology between focal length and rotation speed The pan and tilt speed of the speed dome change according to the zoom rate of the device The movement speed becomes slower when the zoom speed increases and the movement speed becomes higher when the zoom speed decreases 1 2 3 OSD It can display the called preset and preset ID speed dome title speed dome system temperature speed dome location coordinates when touring via menu setting 1 2 4 Preset Setup and Call Preset function is to save the address information such as PTZ pan tilt focus and etc to the memory so that you can quickly adjust the dome and PTZ to the correct position 1 2 5 Auto Scan Camera scans back and forth regularly in a horizontal field Here you need to set left and right limit and scan speed 1 2 6 Auto Touring Add addresses into a routine in a desired order and then set time and stop duration for each address The dome will begin an auto touring between these addresses 1 2 7 Auto Pattern Memorize dome operation such as pan tilt and zoom to repeat You can call it to repeat the previous operation 1 2 8 Privacy Masking Privacy masking is a user defined four sided
39. set STABLE itis to reduce the effect of the vibration on the camera CAMERA FACTORY DEFAULT SETTING Move the cursor to current item and then click confirm button to restore factory default setup e CAMERE RESTART Move the cursor to current item and then click confirm button to reboot the camera BACK Go back to previous menu e EXIT Log out system menu 4 4 4 Function Setting 18 PRESET PRIVACY MASKING AUTO PAN PTZ SPEED AUTO SCAN SET ZERO TOUR POWER UP PATTERN MENU PASSWORD IDLE FUNCTION MENU IDLE TIME OFF TIME TASK PTZ AUTO STOP 158 NEXT PAGE SELF DIAGNOSIS ADJUST BACK Please go back to main menu and move the cursor to FUNCTION SETTING click confirm button You can see the above interface PRESET Move the cursor to PRESET and then click confirm button to go to the third submenu AUTO PAN Move the cursor to PAN and then click confirm button to go to the third submenu AUTO SCAN Move the cursor to SCAN and then click confirm button to go to the third submenu TOUR Move the cursor to TOUR and then click confirm button to go to the third submenu PATTERN Move the cursor to PATTERN and then click confirm button to go to the third submenu IDLE FUNCTION Move the cursor to IDLE FUNCITON and then click confirm button to go to the third submenu TIME TASK Move the cursor to TIME TASK and then click confirm button to go to the third submenu NEXT PAGE It includes PRIVACY MASKING PTZ SPEED SET ZERO POWER
40. t e BRIGHTNESS it is to set the image brightness Please click the left right button on the keyboard or in the speed dome terminal menu to set e SATURATION lt is to set picture saturation Please use the left right button on the keyboard or in the speed dome terminal menu to set e CHROMA SUPPRESS lt is to set picture color control Please use the left right button on the keyboard or in the speed dome terminal menu to set O GAMMA It is to set picture gamma Please use the left right button on the keyboard or in the speed dome terminal menu to set e CONTRAST It is to set picture contrast Please use the left right button on the keyboard or in the speed dome terminal menu to set O IMAGE STYLE It is to set the image style click the left right button on the keyboard or in the speed dome terminal menu to set e BACK Go back to previous menu e EXIT Log out system menu 4 4 3 7 Defog Move the cursor to DEFOG and then click confirm button to go to the submenu to set DEFOG MODE INTENSITY LIGHT INTENSITY MODE LIGHT INTENSITY LEVEL BACK e DEFOG MODE It is to set camera defog mode It includes manual auto off and etc Please use the left right button on the keyboard or in the speed dome terminal menu to set e INTENSITY It is valid when the defog mode is manual Please use the left right button on the keyboard or in the speed dome terminal menu to set e LIGHT INTENSITY MODE It is to set air light intensity mode Pleas
41. t lose when encounter power failure 4 4 1 System Information SYSTEM INFORMATION ADDR INFORMATION SET NORTH LANGUAGE FACTORY DEFAULT RESTART BACK Move the cursor to SYSTEM SETTING and then click confirm button you can go to the third submenu Please use the left right button on the keyboard or in the speed dome terminal menu to set After completed setup please click save button to save current setup e SYSTEM INFORMATION Move the cursor to SYSTEM INFORMATION and then click confirm button to go to the third submenu e ADDR INFORMATION Move the cursor to SITE INFORMATION and then click confirm button to go to the third submenu e SYSTEM TIME SETTING Move the cursor to SYSTEM TIME SETTING and then click confirm button to go to the third submenu e SET NORTH DIRECTION Set dome benchmark direction so that you can know the angel between the benchmark and then current location Please move the cursor to the option and then click confirm button until you see O K Now you have set north direction e LANGUAGE The dome menu language There are several languages for you to select Please use the left right button on the keyboard or in the speed dome terminal menu to set e FACTORY DEFAULT Restore dome factory default setup Please move the cursor to the option and then click confirm button until you see O K Now you can see the IP dome begin rebooting to restore factory default setup e RESTART Reboot the speed dome e BACK Go back
42. to scan Call preset 24 or preset 81 to go to pattern Call preset 25 or preset 82 to go to tour Call preset 30 or preset 96 to stop scan or pattern Call preset 31 or preset 83 to begin rotation Call preset 33 to enable PTZ 180 degrees rotation Call preset 34 to set dome position as 0 Set preset Set preset 26 or 92 to set scan left limit Set preset 27 or 93 to set scan right limit Set preset 22 or 79 to begin record Set preset 23 or 80 to stop record 4 4 4 2 Pan PAN SPEED CALL STOP BACK Move the cursor to PAN button and then click confirm button to go to setup interface PAN SPEED Set dome rotation speed Please use the left right button on the keyboard or in the speed dome terminal menu to set CALL Move the cursor to call item and then click confirm button The dome begins 360 degrees continuous rotation e STOP Highlight stop item and then click confirm button The dome stops rotation e BACK Go back to previous menu e EXIT Log out system menu 4 4 4 3 Scan AUTO SCAN NO SET LEFT LIMIT SET RIGHT LIMIT SCAN SPEED CALL STOP BACK Move the cursor to SCAN button and then click confirm button e AUTO SCAN NO Here is to set auto scan number Please use the left right button on the keyboard or in the speed dome terminal menu to set e SETLEFT LIMIT Here is to set camera left address Click confirm button to save current setup e SET RIGHT LIMIT Here is to set camera right address Click confirm b
43. to setup mode Click left right button to set e GAIN SETTING It is to set camera gain Please use the left right button on the keyboard or in the speed dome terminal menu to set e SHUTTER Itis to set camera shutter speed Please use the left right button on the keyboard or in the speed dome terminal menu to set IRIS SETTING It is to set camera iris value Please use the left right button on the keyboard or in the speed dome terminal menu to set e EXPOSURE COM lt is to set camera exposure compensation Please use the left right button on the keyboard or in the speed dome terminal menu to set Oo 0 0 0 O 14 e SLOW AE In the strong light environment you can lower the camera exposure speed to capture the image and enhance the definition Please use the left right button on the keyboard or in the speed dome terminal menu to set e BLC It is adjust the camera brightness the camera makes brightness compensation automatically to darker target when it is exposed to strong light background and adjust the background with strong light click left right button to set e NEXT PAGE It includes SLOW SHUTTER AUTO SLOW SHUTTER LIMIT AUTO GAIN LIMIT 2DNR CAMERA 3DNR EXPOSURE RESTRAIN AUTO EXPOSURE RECOVERY WDR SETTING Move the cursor to the item click OK button to display other exposure setting items SLOW SHUTTER In lower illumination environment you can lower the cameras auto exposure time to cap
44. to the previous menu e EXIT Log out system menu 4 4 1 1 System information ADDR 1 S BAUD RATE 9600 PARITY NONE SOFTWARE 2 02 14 RHIRFZ BACK EXIT Move the cursor to SYSTEM INFORMATION and then click confirm button you can see the above interface 11 Here you can view dome basic information 4 4 1 2 Address Information ADDR TYPE SOFT ADDR SOFT 001 BACK EXIT Move the cursor to SITE INFORMATION and then click confirm button ADDR TYPE System supports software address only ADDR SOFT It is to display speed dome software address Please use the left right button on the keyboard or in the speed dome terminal menu to set The value ranges from 1 to 255 BACK Go back to the previous menu e EXIT Log out system menu 4 4 2 Display Setting Before the operation please make sure you purchased camera supports zoom function PRESET TITLE EDI Move the cursor to DISPLAY SETTING and then click confirm button you can go to the third submenu Please use the left right button on the keyboard or in the speed dome terminal menu to set After completed setup please click save button to save current setup e PRESET TITLE Display dome preset title or not Please use the left right button on the keyboard or in the speed dome terminal menu to set You can go to Function Setup gt Preset section to set corresponding preset value and preset title AZIMUTH DISP Display dome current coordinates or not
45. ture the image and enhance the definition Please use the left right button on the keyboard or in the speed dome terminal menu to set e AUTO SLOW SHUTTER LIMIT it is to set auto slow shutter limit click left right button to set e AUTO GAIN LIMIT It is to set auto gain limit click left right button to set e HIGH GAIN it is to set camera high gain click left right button to set e NOISE REDUCTION There may be noise when the camera is monitoring the low illumination environments You can use the digital filter to process the noise to guarantee the clear video e 3D NOISE REDUCTION It is to set the speed dome 3D noise reduction setup There is the fourth menu Please move the cursor to highlight current item and then click the OK button to go to the next level menu e EXPOSURE RESTRAIN It is to restrain the abrupt high light on the video in case it affects the video quality Please click the left right button to set e NEXT PAGE It includes SLOW SHUTTER AUTO SLOW SHUTTER LIMIT AUTO GAIN LIMIT 2DNR CAMERA 3DNR EXPOSURE RESTRAIN AUTO EXPOSURE RECOVERY WDR SETTING Move the cursor to the item click OK button to display other exposure setting items e BRIGHTNESS RESTRAIN It is to set the brightness restrain of the camera click left right button to set e AE RECOVERY Manually click the and button on the PTZ interface system cam resume previous exposure value after
46. two modes normal open and normal close e The default setup 7 channel alarm input GND Alarm input ground end 28 e Two alarm output channels When there is an alarm from current channel system activates relay or not ALARM e Alarm output relay default setup is NO OUT Note The default setup 1 channel alarm output 2 channel alarm output optional 5 2 System Layout 5 2 1 System Connection Please refer to Figure 5 1 for system connection information Network Output AC220V Input Power Output Transformer DVR Figure 5 1 5 2 2 Alarm Connection Please refer to Figure 5 2 for alarm connection information Figure 5 2 29 6 FAQ 6 1 Daily Maintenance Please clean dome cover regularly to get vivid image Handle the cover with care Use water to wash Don t use cloth to clean Note The sweat from your hand may erode plating surface your nail may scrape dome cover resulting in blur image 6 2 Problems and Solutions SYMPTOM CAUSE SOLUTION 1 No self diagnosis Red LED is not on Check power is connected or no video signal e Your power supplying does properly earthed when connect dome to power not apply to the power Or connection is too loose e Power off or transformer problem Check power supply condition or check transformer Red LED light on the power board is on Power supplying is low Someth
47. utton to save current setup e SCAN SPEED Please use the left right button on the keyboard or in the speed dome terminal menu to set e CALL Please input auto scan number first and then please move the cursor to CALL and click confirm button to activate auto scan function e STOP Here is to terminate auto scan function e BACK Go back to previous menu e EXIT Log out system menu 4 4 4 4 Tour TOUR NO TOUR SETTING DELETE TOUR CALL STOP BACK PRESET DWELL 000 005 000 005 000 005 000 005 000 005 000 005 000 005 Move the cursor to highlight TOUR item and then click confirm button to go to set interface TOUR NO Here is to ser tour number Please use the left right button on the keyboard or in the speed dome terminal menu to set TOUR SETTING Move the cursor to tour setting item and then click confirm button You can see the following interface Here you can add or remove the preset and set the corresponding dwell time and call speed m DWELL Here is t set dwell time Please use the left right button on the keyboard or in the speed dome terminal menu to set m SPEED Here you can set the speed value 21 When you move the cursor to one tour number you can use left right button to turn the page When you move the cursor to one tour number please click confirm button to set the tour Please use up down button to set preset number dwell time and speed Use the left right button to go to the next tour