Home
Destiny 6100 - Allied Fire and Security
Contents
1. Flashing when new information is available solid after status has been asked for and spoken and off when no information is present HOME On when armed to HOME Press H to arm to HOME AWAY On when armed to AWAY Press A to arm to AWAY NIGHT Both HOME and AWAY LED s are on when armed to NIGHT Press H any time system is armed to HOME to change to NIGHT Pressing H when system is armed to NIGHT will change arming back to HOME STATUS Pressing this key will cause the system to immediately speak system status MONITOR Pressing this key toggles the system between the three possible monitor conditions Monitor On System will announce doors and windows when opened Monitor Off System will not announce doors and windows when opened Beep System will beep when doors and windows are opened Fl and F2 These key s functions are programmable and will be explained by your installer Fl F2 BACKLIGHT INTENSITY You can control the brightness level of the key backlight ing The simultaneous depression of the 4 and 7 keys will step the backlighting through 7 different levels Press 4 and 7 simultaneously a number of times until the backlighting is totally off We will define all backlighting off as level 1 Levels 2 through 7 will take the key backlighting through 6 progressively brighter levels RK 36 KEYPAD GREEN POWER YELLOW STATUS RED HOME GREEN AWAY CD C2 F2
2. smoke detectors activate the system they will latch ON until you reset them To do so enter your primary code followed by 6 The system will say SMOKE POWER REMOTE PHONE ACCESE REMOTE PHONE ACCESS You can gain access to the system from any touch tone phone when you are away from home If you use an answering machine your installer will program an override digit which you will use to bypass the answering machine and get directly into the system Following is a step by step description of phone access 1 Dial your home number from any touch tone phone 2 The system will answer after a programmed number of rings and you will hear an acknowledgment tone that your system is ready and waiting If you have an answering machine wait for it to answer then press the programmed override digit within 10 seconds and you will then hear the acknowledgment tone indicating that your system is ready and waiting 3 You must now enter your disarm code and the system will speak your system status If you do not enter an acceptable code within 5 seconds of the tone you heard in Step 2 the system will automatically hang up 4 Now that you have entered your code and have received the system status your telephone can be used as a keypad To hear the status of your system again press the first digit of your disarm code and wait three seconds The system status will be repeated through your telephone receiver To disarm
3. If you wish to return to the HOME mode simply push the or H key any time the system is in the NIGHT mode Force Arming the system If you attempt to arm the system to either HOME or AWAY but you hear ZONES OPEN over the phone or through the speaker and notice that neither the HOME LED nor the AWAY LED has come on the system is NOT armed However the system can be FORCE ARMED Push the or H or or A key a second time within 10 seconds If arming to HOME the red HOME LED will now light and FORCE ARMED TO HOME will be heard indicating that the system is now ARMED to HOME If arming to AWAY the green AWAY LED will now light and FORCE ARMED TO AWAY will be heard When FORCE ARMED either to HOME or AWAY the yellow STATUS LED will be lit You can find out which zones are open by requesting system status PLEASE NOTE When you FORCE ARM your system security is compromised because the open zone will be ignored by the system Check with your installer to determine how the open zone will again be part of the system Zones which operate 24 hours a day such as FIRE and PANIC are always armed and take priority over all other types of protection in the system 10 Technical Manuals Online http www tech man com RK 36 KEYPAD LED s and SPECIAL KEYS POWER On when AC or back up battery power is present If AC power is lost the STATUS LED will flash and the system will speak POWER OFF one time STATUS
4. stop the audible alarms Check with your installer eee and or central station to determine the proper procedure for dealing with false or accidental alarms RK 36 KEYPAD Depending on the structure of your central station you may need to notify the central station or they MONITOR MODE MONITOR MODE FROM A PHONE may call you In either event be prepared to recite FROM A PHONE See RK 36 Keypad description for explanation of your central station account number or abort code to Monitor Mode verify your identity To change monitor mode from a phone access the system refer to Local Access or Remote Access then enter the user code plus the 2 digit This toggles to the monitor mode 6 11 Technical Manuals Online http www tech man com ARMING ARMING THE SYSTEM TO NIGHT OPTIONAL PUSH THE OR H KEY AGAIN FORCE ARMING THE SYSTEM PLEASE NOTE LED will not light and you will hear the system say ZONES OPEN over the phone or through the speaker which indicates that the system did NOT arm See Force Arming to continue Arming the system to NIGHT Optional Arm the system to HOME mode See item 2 Push the or H key again The green AWAY LED will light with the red HOME LED and the system will say ARMED TO NIGHT over the phone or through the speaker When armed to the NIGHT mode the perimeter entry delay zones become instant and your installer may program some interior zones to be active
5. 5 Preventing accidental arming cont AS KEYPADS USING YOUR TELEPHONES AS KEYPADS If you want to prevent anyone from accidentally PREVENTING arming the system your installer can program the ACCIDENTAL The system can be programmed to allow the use of your alarm system to require your disarm code to also ARMING home telephones as keypads You will notice that the serve as an arming code When programmed to this keypad shown below duplicates the keys on your phone option you must enter your code before you press The key on the phone is replaced by the A key on the the or A key AWAY mode or or H key HOME keypad and the key on the phone is replaced by the H mode to arm the system key on the keypad Your installer will let you know which key or keys will access the system The local phone access code must be entered within 5 seconds of DISARMING Beene picking up the phone If the correct code is entered within 5 seconds you will hear the system How to TURN OFF the alarm system acknowledgement tone or system status At this point you can control the system from the phone just like from the Enter your disarm code hardwired keypad ee When the system is disarmed you will hear CONTROL NOTE NOTE If your regular phone line is out for any reason IS DISARMED over the phone or through the you will not hear a dial tone when you pick up a phone speaker and the red HOME LED and or green AWAY however you will hear a se
6. new 4 digit code or hit the A key to delete the user code from step 3 If a new 4 digit code is entered the system will speak EXIT after the 4th digit If a code is deleted the system will speak CODE OUT 12 Technical Manuals Online http www tech man com EXIT DELAY Time permitted to leave the premises after arming the system A 30 second delay is set at the factory but your installer can program a longer or shorter time as desired EXTENDED MONITOR Allows a zone to speak continu ously or for a programmable time period when tripped Example would be pool door open pool door open FORCE ARM To override the security system s initial refusal to arm because of an open zone When the system is force armed it will disregard any open zones until they have been closed HOME Arming mode for use when you are at HOME Only perimeter devices are armed allowing you to move about freely within the premises The system will be programmed to eliminate all entrance delays when armed to home This might be preferable for individuals living alone INTERIOR ZONES Zones consisting of motion detectors or any other detection devices located within the premises LCD Liquid Crystal Display Will display all system status in English LED Light emitting diode These are used as indicators of system conditions on keypads NIGHT Arming mode for use when everyone is in for the NIGHT All perimeter devi
7. ALARM SIGNALS ALARM SIGNALS Understanding the alarm signals FIRE Alarm a continuous steady loud tone emitted through the speakers Your installer may also program the system to speak in between tones saying FIRE description of zone that activated REMAIN CALM LEAVE IMMEDI ATELY EMERGENCY Alarm a low pulsing tone is emitted through the speakers Your installer may also program the system to speak in between tones saying ALERT description of zone that activated PANIC Alarm a loud pulsing tone is emitted through the speakers Your installer may also program the system to speak in between tones saying ALERT ALERT descrip tion of zone that activated BURGLAR Alarm a loud yelping tone is emitted through the speakers Your installer may also program the system to speak in between tones saying INTRUSION DETECTED INTRUSION DETECTED description of the zone that activated PREALARM tone a steady low volume tone emitted through the speakers during the entrance delay This tone is activated by opening the delay door and will continue until the security system is disarmed If the system is not disarmed within the programmed delay time the BUR GLAR alarm will sound A broken or pulsing prealarm tone signals that an alarm activation has occurred while you were gone If the option is programmed to speak during prealarm the system will speak entry detected followed by the zone
8. BYPASS NOTE BYPASS To enter BYPASS mode your system must be disarmed Make sure the system is disarmed and follow the steps below 1 Enter your code and immediately press the 9 key to gain entry into BYPASS mode You will hear BYPASSED MODE ENTER ZONE NUMBER 2 Enter the two digit number of the zone use a leading zero if necessary you wish to bypass You will hear description of selected zone BYPASSED ON or OFF Only zones that exist in the system can be bypassed If an invalid zone number is entered refusal will be signaled by three beeps 3 Press the or A key The yellow status led will light to indicate that the zone is bypassed The RK 36 Keypad LCD will display the zone descriptor and beep A second push of the or A key within 10 seconds will remove the zone from bypass and the yellow STATUS LED will clear as well as the zone descriptor on the LCD display 4 Pressing 00 while in BYPASS mode will clear all bypassed zones 5 Press the or H key to exit BYPASS mode You will hear EXIT NOTE If ten seconds pass without pressing any keys the system will automatically exit BYPASS mode CHANGING DELETING USER CODES Assuming your primary code is 1 2 3 4 1 Enter 1 2 3 4 7 2 The system will speak ENTER USER NUMBER 3 Enter 2 digit user number 01 32 The system will speak ENTER CODE X X X X 01 32 You do not need to clear a code to change a code 4 Enter the
9. ETECTOR up the frequency of breaking glass and instantly alerts the control panel A motion detector is used as a second MOTION line of defense to detect intruders within a protected DETECTOR area The smoke detector is always on SMOKE DETECTOR TELEPHONE KEYPADS Your phones and keypads are used to send commands to your security system Because your phones and keypads are your access to operating the security system the main emphasis of this user s manual is to help you understand their operation Before reading this manual it is recommended that you become familiar with the terms and definitions in the Glossary GLOSSARY ALERT ANNUNCIATION ARM AWAY BYPASS CENTRAL STATION COMMUNICATOR CONTROL PANEL DISARM DISARM CODE ENTRANCE DELAY GLOSSARY ALERT The alert status indicates the system has been tripped The system will remember the alert status until cleared To clear the alert status simply re arm the panel ANNUNCIATION Beep or speech emitted over the phone or through system speakers to announce activity or report system status ARM To turn the security system ON to detect intrusion There are three modes or levels of arming AWAY HOME or NIGHT AWAY Arming mode for use when you are AWAY from the premises All interior and perimeter devices are armed intrusion and or movement within the premises will activate the alarm BYPASS To temporarily remove a zone from the sy
10. HE ORA KEY NOTE ARMING THE SYSTEM TO HOME PUSH THE OR H KEY
11. NE ACCESS Using Your Telephones As Keypads s s sssssssessssesissesssseses 6 LED INDICATIONS ROWE n a ea EE E AEE EEAS StatUs e inns HOME ceeeeeeees AWAY oeeeseseeeseeees Ni Bb sess cepetscadehessatetae E E KEYPAD FUNCTIONS ILLE E eben E saceoe E E OE MONITO a aeaee rasanan ae seas sven devancsesvaverestecpdesdnavasavensunatesedecs F1 and F2 Backlight lintensity s 2 2is syescaStvsctestestessaes reaa aE 7 ALARM SIGNALS v ir ia sie iain 8 ARMING pinaka saiya eroas a ts 9 11 DISARMING ivi iniisa an e a 11 1AA La EA A A A E 12 CHANGING DELETING USER CODES cc0cc00sseseseess 12 13 PANIC FROM YOUR PHONE cccccccccsssssessessesseseeeeeeeseneees 13 KEYPAD ACTIVATION S 0cccsccsccssesessesseseeseeseeeesetseseensensees 13 RESETTING AN ACTIVATED SMOKE DETECTOR 0 006 14 REMOTE PHONE ACCESS scsccsccssesssssessesesseesesesseesenseesees 14 OPTIONAL EQUIPMENT Lighting Options erae ae N 15 Light and Appliance Control ACCESS ss s sssssssssssesiseseseseseee 15 2 WAY LISTEN IN annn a a 15 16 SETTING CLOCK TIME cccccccsccscesscesessesessecseeeeessesensenseeees 16 The APEX logo is a trademark and DESTINY is a registered trademark of APEX Division of Pittway Corporation KEYPAD AND PHONE DIGIT QUICK REFERENCE NOTE KEYPAD AND PHONE DIGIT QUICK REFERENCE User code 1 speaks time User code 2 toggles monitor mode User code 3 toggles extended monit
12. NOTE NOTE When in 2 way mode the following key functions apply Digit 1 turns on microphone 1 2 turns on microphone 2 3 turns on microphone 3 4 turns off microphone 1 5 turns off microphone 2 6 turns off microphone 3 7 changes to high microphone sensitivity 8 changes to normal microphone sensitivity 9 all microphones on 0 Exit to keypad mode or will hang up programming option Listen Talk NOTE Some central stations may designate other key functions when in 2 way mode If this is the case the homeowner listen in will follow the new key assignments New Digit 1 4 7 0 2 5 8 3 6 9 CHANGING THE CLOCK TIME To set or change the system time press the 2 amp 8 keys simultaneously from a hardwired keypad The system will respond by speaking enter four digit time Simply enter the time in a 12 hour format After the time is entered the system will say enter 1 AM 2 PM After selecting AM or PM the system will confirm the entered time If an invalid entry is made the system will speak error and wait for a valid entry 16 Technical Manuals Online http www tech man com TABLE OF CONTENTS INTRODUCTION Control Panel sssassioni aies nest A ea ER 3 Detection DEVICES ae csscccasecevessetscssscanecvarcesvsncceben cevesseresstecess 3 Telephone Keypads aissis iriiri eranskinen iaeiei oyini 3 GLOSSARY nnie e e aa a aa eaa 4 5 LOCAL PHO
13. ces become instant and some interior zones can be active PERIMETER ZONES Zones consisting of door and window contacts and glass break detectors which will detect an intruder before he gains entry into the premises PREALARM SPEECH When the system is armed and someone enters the premises through a delay door the system speaks entry detected followed by the word description programmed for that door Example entry detected front door entry detected front door This speech will be heard for the duration of the entrance delay If the disarm code is not entered within the programmed time theBURGLAR ALARM will sound If an alarm took place while you were gone then the system would speak system showing alert followed by the prealarm speech PREALARM TONE Steady low volume sound emitted through the speakers when the entry delay door is opened This tone will continue until the disarm code is entered to disarm the system If the disarm code is not entered within the programmed time the BURGLAR ALARM will sound A pulsing prealarm tone indicates there was an activation while you were gone ZONE Any area or point of protection in the security system such as doors windows and all other areas covered by detection devices GLOSSARY cont EXIT DELAY FORCE ARM HOME INTERIOR ZONES LCD LED NIGHT PERIMETER ZONES PREALARM SPEECH PREALARM TONE ZONE USING YOUR ARMING TELEPHONES LOCAL PHONE ACCESS
14. descriptor instead of a solid prealarm tone DOOR amp WINDOW ANNUNCIATOR The system will speak up to four words describing a zone followed by the word OPEN If you would prefer not to hear anything when you open a window or door simply access the system from one of your phones and press your code followed by 2 or press the MONITOR key at an optional keypad and you will hear MONITOR OFF Now each time you open a protected door or window there will be status available over the phone and or visual indication at the keypad but no sound If you prefer to hear a beep when you open enter your code followed by 2 or press the MONITOR key again You will now hear one beep Enter your code followed by 2 or press the MONITOR key and you will hear MONITOR ON and the system will return to speech No monitor will be heard for a door or window that is bypassed Loss of AC power signal Anytime that you lose AC power your security system automatically switches to the backup battery and speaks POWER OFF one time through the speaker 8 Technical Manuals Online http www tech man com ARMING When referring to operation from a phone the following instructions will assume that access to the system has already taken place Remember your installer has programmed a one to four digit code which you will enter when you pick up the phone to get access to the system How to TURN ON the alarm system to provide protection 1 Ar
15. imary disarm code 2 Follow steps 2 through 4 above however in step 3 instead of entering 1 you will enter the two digit number of the code you wish to initiate or change One or more of your auxiliary codes can be a disappear ing code which is useful for domestic workers repair men or anyone whose access to your home you want to limit Your installer can program the number of times a disappearing code will remain active each time it is assigned One or more of your auxiliary codes can be used as a duress code Your installer can program your system so that the use of a duress code will give the appearance of being a normal disarming code However even though no alarm is sounded at the location of the security system there will be a silent alarm signal sent to the central station For the duress code to function as designated no normal codes can be the same as any duress code PANIC FROM YOUR PHONE Anytime you have accessed your system from an on site phone pressing the 0 key five times in a row will initiate a PANIC alarm NOTE Never program a disarm code with all zeroes KEYPAD ACTIVATIONS Simultaneously pressing certain keys on the keypad will result in the following 3 and STATUS FIRE Alarm yy 6 and MONITOR EMERGENCY Alarm A 9 and F1 PANIC Alarm Se MONITOR Door amp Window annunciator ON with beep ON with speech or OFF PANIC FROM YOUR PHONE KEYPAD ACTIVATIONS 13
16. ming the system to AWAY Push the or A key If no zones are open the green AWAY LED will light and the system will say ARMED TO AWAY over the phone or through the speaker The security system is now on or armed When armed in the AWAY mode all interior zones including motion detectors become active as well as all perimeter zones If any zone is open while attempting to arm the system the AWAY LED will not light and the system will say ZONES OPEN over the phone or through the speaker indicating that the system did NOT arm because a window or door is OPEN See Force Arm to continue to arm After you have ARMED the system you must leave through the designated entry exit door within the specified exit delay time Your installer can program the exit delay time you desire NOTE If a zone is opened before the exit delay expires or the system is force armed then that zone will not be part of the system until that zone is closed 2 Arming the system to HOME Push the or H key If no zones are open the red HOME LED will light and you will hear the system say ARMED TO HOME over the phone or through the speaker The security system is now on or armed When armed to the HOME mode only the exterior or perimeter zones are armed This will allow you to move about freely within your home If any zone is open while attempting to arm the system the HOME ARMING ARMING THE SYSTEM TO AWAY PUSH T
17. or A on off User code 4 toggles extended monitor B on off User code 5 silences day zone speech after activation User code 6 resets hardwire smoke detector User code 7 auxiliary user code entry delete mode User code 8 speaks long term memory User code 9 manual bypass mode User code 0 immediate communicator test no siren NOTE Only full function codes can perform the above operations The DESTINY control panel provides many conve nience related features and options that greatly en hance the system s interaction with your daily functions Depending on your system s specific configuration you may or may not have the following options integrated into your control panel Enhanced features and options e automatic arming disarming based on time of day 2 way voice with central station for alarm verification homeowner listen in from local or remote phones homeowner global paging from local and remote phones automatic control of lights and appliances based on time of day e manual control of lights and appliances from keypads local and remote phones e complete energy management functions e spoken temperature upon request from keypads local and remote phones e Automatic and manual thermostat setback forward operation e thermostat control by time of day Specialized convenience features and options e electric garage door operation from keypads and phones e front door visitor to homeowner communication
18. ries of tones indicating the LED will go out line is gone If this is the case there is no need to access the system because the phone will already be a system keypad when it is picked up Press any key and the tones When you open the entry door while the system is will stop If your system communicates to a central station armed to AWAY you may hear PRE ALARM and there is an activation you can pick up a phone and spoken instead of hearing the tone This is the simply enter your disarm code The system will recognize prealarm tone and it will continue until you enter the phone as a keypad as soon as you pick it up your disarm code You have 20 seconds to disarm the system before the BURGLAR alarm will activate Your NOTE NOTE When you access the system from your home installer can program a longer or shorter entry delay phone your normal incoming phone line is discon time at your request nected In the case of an incoming call you will hear one second tones similar to call waiting To answer the If the prealarm tone is not a continuous steady tone call simply hang up to terminate telephone keypad access but is instead a series of broken tones this is an indication that the security system was activated 2 8 while you were gone and the yellow STATUS LED a will be flashing BDA 9 G1 DOD Oa In the unlikely event of a FALSE or ACCIDENTAL ALARM enter your code to disarm the system and
19. s without opening door e motion activated lighting e vehicle activated driveway annunciation The following 2 digit functions are only available from the RK 36 series keypads and not from phones 1 amp 3 and or 3 amp status initiate fire alarm 4 amp 6 and or 6 amp monitor initiate medical alarm inside speaker only 7 amp 9 and or 9 amp F1 initiate panic alarm 1 amp 7 programmable default enters remote control 2 amp 8 changes time of day in the system clock 3 amp 9 programmable default toggles monitor function 2 Technical Manuals Online http www tech man com OPTIONAL EQUIPMENT LIGHTING OPTIONS LIGHTING OPTIONS OPTIONAL EQUIPMENT The DESTINY allows you to turn on different lights and or appliances when using the optional lighting accessories Different lights can come on for an alarm condition or other system activity such as prealarm entry delay Your system can also be programmed to turn lights on or off at certain times of the day as well as providing you with the ability to control your lights from any keypad local phone and or remote phone to include cellular and cordless types LIGHTS AND APPLIANCE LIGHTS AND CONTROL ACCESS PAON ROL ACCESS From your phones either locally or remotely access the system as you normally would see local and remote phone access and enter 8 8 8 8 From the keypad the F1 or F2 keys may be used instead of 8 8 8 8 After entering 8 8 8 8 or F1 the s
20. stem that would normally be active when the system is armed If a zone is bypassed it is not part of the system and will not initiate an alarm CENTRAL STATION If your security system is monitored this is the agency that receives the incoming burglary or emergency message from the security system and reports it to the proper authorities COMMUNICATOR The device in the control panel that reports all burglary and emergency alarms to the central station via telephone lines CONTROL PANEL The heart of the security system Only a qualified security system technician should open the container which houses the control panel DISARM To turn the security system OFF or silence alarm activations including fire alarms that may occur while the system is armed DISARM CODE The three or four digit number you enter to disarm the security system The system will accept 32 different disarm codes including disappearing and duress codes Your disarm code allows you to control the system ENTRANCE DELAY Time permitted to enter the armed premises and disarm the security system before the alarm is activated A 20 second delay is set at the factory but your installer can program a longer or shorter time as desired 4 Technical Manuals Online http www tech man com The DESTINY allows 32 different disarm codes Check with your installer to find out how many codes are enabled To enter or change an auxiliary code 1 Enter your pr
21. the system over the phone simply enter your disarm code on the telephone keypad To arm the system use the key to arm to AWAY or use the key to arm to HOME Once you have finished simply hang up the phone and the system will hang up at the other end If you do not press any digits for a period of 15 seconds the system will automatically hang up NOTE NOTE Your installer can increase or decrease this time 14 Technical Manuals Online http www tech man com INTRODUCTION DESTINY You have made a wise decision to protect your family and property with the DESTINY Security System The DESTINY has been designed to provide you with a maximum level of security while being as simple as possible to understand and operate Your DESTINY Security System consists of 1 Control panel 2 Detection devices 3 Your telephones 4 Keypad s CONTROL PANEL The control panel is the heart of the security system and includes a communicator which transmits information to the central station The control panel is housed in a metal cabinet which should only be opened by a qualified security system technician DETECTION DEVICES The detection devices continually monitor the status of the premises Switches will alert the control panel of an SWITCHES open door or window A transmitter will do the same as TRANSMITTER well as indicate when it has a weak battery The glass GLASS BREAK break detector is exactly what the name implies it picks D
22. ystem will speak enter remote unit or if programmed it will speak a menu of the active channels in the system At this point enter a two digit channel number from 07 to 33 Your installer will let you know what channels control which lights or appliances Channel 33 is an all lights on off channel that can activate a group or bank of lights at the same time Afte rentering the desired channel the system will echo your choice by speaking the programmed word descriptions for that channel To activate the channel the A or key turns the unit on and the H or key turns the unit off if the dimming option is enabled then the successive depressions of the A or key turns the unit off If the dimming option is enabled then the successive depres sions of the A or key will step through the six levels To exit remote control enter 0 0 or any F key If no digit is entered within 20 seconds the system will automatically exit NOTE When twenty seconds pass without pressing any NOTE keys the system will automatically exit lights and appliance control and return to normal operation 2 WAY AND LISTEN IN AUSTEN IN 1 Access the system see Local Access or Remote Access 2 Press 9 9 9 9 to enter Listen mode 3 Press to talk to listen 4 Hang up when done or press 0 to return to keypad mode 15 RESETTING AN ACTIVATED RESETTING AN ACTIVATED SMOKE SMOKE DETECTOR DETECTOR Whenever any of your wired non battery powered