Home

vwr.com - 868121. vwr

image

Contents

1. Supplier Partnerships for Customer Solutions BeEWuUIF Essential innovations from VWR Are you registered f Get all the lat WWW VWTr COM ISSUE 6 JUNE 2008 Successful effective autoclaving from Tuttnauer and Ebro page 4 Presenting performance and excellent prices in brilliant new colours the new VWR Collection benchtop centrifuges page 8 Bellingham Stanley ADP410 polarimeter and RFM300 refractometers page 13 VWR Exclusive the new IKA rotary evaporator family page 14 Competition Do you like a puzzle Test yourself against the clock and try your hand at our competition on www vwr com and you could win a handy magnetic tree Simply put all the pieces of the puzzle together to make our special VWR equip picture the fastest 10 entries will win Once you have solved the puzzle click on the send button and fill in your name and email address to be entered into our prize draw Closing date for entries 31 10 2008 Editor VWR International Europe bvba Haasrode Researchpark Zone 3 Geldenaaksebaan 464 3001 Leuven Belgium Copywriting VWR International Europe bvba Layout and typesetting Marketing Services VWR Printing Stork Druckerei GmbH Bruchsal Germany No part of this publication may be reproduced or copied without prior permission by writing of VWR International Europe Run 177 000 copies Publication date June 2008 Due t
2. VWRbioMarkeshop valid until July 30th The GenoMini offers reproducible high resolution digital images for gel documentation GenoMini is ideal if you have a limited budget because you can purchase the basic system and then add a UV transillu minator white light table or conversion screen safety hood mini darkroom and printer as well as GenoSoft analysis software Features The GenoSmart darkroom allows you to use many bench top UV transilluminators even one you might currently have in your laboratory The system is compatible with most commonly used electrophoresis gel stains and by using a white or blue light converter you can also capture images from other applications such as petri dishes cells in flasks autoradiographs mem branes spot and slot blots of DNA RNA or protein TLC plates and more e Real time images from 8 bit CCD Camera 768 x 582 pixel resolution e Self contained microprocessor controlled darkroom e Integrated colour LCD screen for image viewing e White Epi light e Instant on screen saturation detection e Rapid photographic print production e Transilluminator optional e White light converter optional Description Gel documentation system GenoSmart 730 3000 Digital video system with integral LCD monitor Fits any benchtop transilluminator not supplied June 2008 VWR Equip Magazine _ Issue6 SeQuUIP Essential innovations from VWR The n
3. 1 3419 531 0286 531 3448 531 3449 RV 10 digital V with vertical glassware RV 10 digital V C with vertical glassware coated RV 10 digital D with diagonal glassware RV 10 digital D C with diagonal glassware coated June 2008 Applications For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip KBF series constant climate chambers deliver humidity under high pressure BINDER sets new standards for humidification in climatic chambers BINDER KBF Excellent homogenous conditions even with a large number of samples KBF 240 model easily accessible with the new upright format B The KBF series constant climatic chambers have been improved once again in line with the company s philosophy of creating the Best conditions for your success A novel humidification system along with an improved refrigeration system and housing design provides even better performance for climatic testing including compliance with the ICH guideline Q1A This reserve capacity is also utilised for the refinement of the well known ICH lighting system for compliance in the areas of light intensity and light distribution pursuant to ICH Q1A By combining it with the complete documentation of measured data and remote monitoring BINDER offers a complete package for climatic testing and storage under control
4. 1 Bellingham Sugar Brix 0 00004 0 03 Stanley VWR Equip Magazine Issue 6 June 2008 I SEeQuUIP Essential innovations from VWR The New Rotary Evaporators from IKA RV 10 basic V RV 10 basic V C RV 10 basic D RV 10 basic D C The newly developed range of rotary evaporators from IKA offer an ergonomic compact design with innovative functions to ensure great results Best of all these units offer exceptional value for money RV 10 basic RV 10 digital Optional accessories on request VWR Equip Magazine Issue6 These units feature the HB 10 basic integrated heating bath with either saving vertical or diagonal glassware 1 litre and are very easy to operate from the control panel at the front of the unit which is safe to use even when the unit is in action The water or oil heating bath heats up quickly as the volume has been optimised and an optional pivoting safety hood is available The bath has integrated carry handles for easy and safe handling and offers the versatility of being used as stand alone unit for other tasks In fact safety is very much in mind when using these instruments as demonstrated by the unique safety stop function of the motorised lift if the power cuts out the evaporator assembly is automatically lifted out of the heating bath The heating bath itself has an adjustable safety circuit In addition you can set the lowering limit so that it is recog
5. 40 F to 284 F burst pressure 10 bar 145 psi 140 C 284 F up to 1h max Accuracy 0 5 of measuring range 0 3 C 20 5 F Resolution 1 mbar 0 02 psi 0 1 C 0 2 F Measuring probe ceramic pressure sensor Pt 1000 1 x Pressure Temperature Data Logger 1 x Pressure Temperature Data Logger EBI 125 A PT 3 EBI 125 A PT AK 5 N 5 X Temperature Logger EBI 125 A EM 500 F1 6 2K incl calibration certificate 1 x Silicone protection box EBI SSB BD 1 x Silicone protection box EBI SSB BD 1 x Silicone protection box EBI SSB EM 1 x Software Winlog pharm 1 x Software Winlog pharm 1 x Interface EBI AE S Version C 1 x 8 port Interface EBI AE S8 1 User manual transport case User manual transport case ebr0 ebro Starter Set EBI AT S 620 1374 MEASUREMENTS FOR LIFE ebro Validation Set EBI AT V6 620 1376 VWR Collection Autoclavable Biohazard Bags 0 02 mm Dimensions W x H cm Pk Cat No Clear Ideal for processing of biohazardous materials which require autoclaving 30 5 x 61 200 129 0028 prior to disposal Available with or without temperature indicator High 61 x 91 4 200 129 0029 integrity polypropylene bag withstands 135 C maximum autoclave tem Orange with temperature indicator perature Twist tie closure allows bag to expand and vent steam during 35 6 x 48 3 200 129 0024 cooling Bag resists punctures tears and leaks and meets the 165g dart 48 3 x 61 200 129 0025 drop standard performed as requ
6. bon typically varies from 500 800 ppb in feed tap water depending on local conditions Following the Direct Q 3 UV system s first purification step reverse osmosis 98 of the organic contaminants are removed The TOC concentration of the permeate Type III water in the internal reservoir is typically between 10 20 ppb In the next step the ion exchange resins and the UV lamp reduce this level to a value of lt 5 ppb measured at the Direct Q 3 UV system s outlet Bottled water often shows a higher TOC value which in addition increases each time water is poured from the bottle This is mainly due to the absorption of airborne organic contaminants Ultrapure water purification systems always produce fresh ultrapure water on demand avoiding this problem The easy to use Direct Q 3 UV water purification system guarantees the production of high quality ultrapure water and is ideal for critical applications in trace TOC analysis TOC lt 5 ppb as well as in standard analysis TOC lt 30 ppb Hence it is a better alternative to bottled water for users needing up to ten litres per day TM VWR Equip Magazine Issue 6 June 2008 i SEeQuUIP Essential innovations from VWR Make your own Hydrogen and Nitrogen Gas generators have been used Main applications for gas generators for many years in industrial ae HYDROGEN NITROGEN applications but more recently e Carrier gas in capillary gas chromatography e For LC MS have fo
7. e and remote Auto cable are included in the delivery Optional PT100 work and the drive unit is delivered with a temperature probe for temperature surveillance can standard RS232 interface with software and be directly connected to the drive unit cable as well as a port for the connection of Great choice of dispersing aggregates stands and an optional temperature probe accessories available Hammer Mill and Blade Mill POLYMIX PX MFC 90 D The new POLYMIX PX MFC 90 D lab mill with Working volume funnel Approx 300 ml interchangeable grinding attachments and sieves Speed range 50 6 000 min 1 with mesh sizes from 0 2 to 6 mm is suitable for 9 mm sieves 0 2 6 interchangeable all dry mill applications in the lab Thanks to the User interface LED with speed knob powerful drive unit with LED and high speed Ower 1O Supply 230 115 V 50 60 Hz levels dry and brittle substances like cereals i ect aes b Noise level w o load lt 70 dB A malt pectin raw amp roasted coffee beans bones Dimensions LH 251 x 325 x 480 mm fins fish gravel stone amber mortar etc Weight drive unit only 12 kg In addition dry and stringy or ductile substances like wood roots straw cork dried degreased meat wool cotton leashes paper coal turf dried resins synthetic materials etc can be processed Lab mill available as hammer mill or blade mill Grinding attachments are interchangeable Includes drive unit mill
8. ectic point samples e Vacuum monitor in mBar Pa or Torr e Temperature monitor in C or F e Vacuum control valve maintains set point vacuum level and bleeds system after freeze drying is complete e Available in benchtop and console models e Drying chamber glassware and vacuum pump are sold separately e Labconco offers a full line of FreeZone Freeze Dry Systems and accessories including freeze dryers with collector sizes from 1 to 18 litres FreeZone Triad Systems with built in stoppering tray dryer and a variety of drying chambers and freeze drying glassware Features and Benefits e Microprocessor controlled cooling and heating from 4 to 100 C in one degree increments speed evaporation while protecting heat sensitive samples e Microprocessor controlled centrifugal motion eliminates bumping and foaming and maximises recovery of trace solutes e Memory stores 9 user set programs e Large chamber accommodates a variety of rotors that hold up to 132 small samples rotor sold separately e Available with acrylic or glass lid e Cold trap vacuum pump and rotor are sold separately e Labconco offers a full line of CentriVap Vacuum Concentrators including Acid Resistant CentriVap Concentrators and floor mounted CentriVap Mobile Systems VWR Equip Magazine Issue6 June 2008 Essential equipment Application VACUUBRAND rotary vane pumps XS are used in any application where vacuum levels from a few millibar down
9. elayed boiling as specified by technical safety regulations in compliance with European and International standards Door lock safety switch prevents the sterilisation program from being started if the door has not been closed properly Water level safety device prevents the autoclave from being heated up if insufficient water is available for steam generation Overpressure valve releases over pressure to prevent high pressure explosion m mn I Mi M iip pas i Pa r i Tuttnauer Your Sterilization amp Infection Control Partners June 2008 For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip Routine checks and validation The ebro Starter Set EBI AT S is the right kit for routine checks and validation of steam sterilisers and washer disinfectors in the pharmaceutical market According to the European Regulations EN 554 EN ISO 17665 and EN ISO 15883 Your advantage e Routine checks and validation of steam sterilisers according to EN 554 EN ISO 17665 e Routine checks and validation of washer disinfectors according to EN ISO 15883 e System conforms to FDA 21 CFR Part 11 conform e Monitoring pressure and temperature inside the process Pressure Temperature Memory 9 000 readings 9 000 readings Measuring range 0 bar to 4 bar 0 psi to 58 psi 40 C to 140 C
10. ext generation in thermal cycling technology The VWR Collection thermal cyclers J Colour touch screen display are easy to use intuitive yet incredibly powerful The vital elements of temperature The software interface for all programming and running of the cyclers is controlled by a bright easy to view TFT full colour VGA touch screen monitor display Users have the choice of control either by screen stylus or optional USB mouse uniformity and accuracy are met time after time cycle after cycle The UnoCycler is the ideal choice for users who require superb thermal performance in a single headed unit While for higher throughput requirements the Duo and QuattroCycler have two or four fully independent thermal bays respectively Easy to use intuitive yet powerful and flexible Simple drag and drop commands with easy to recognise icons make programming a simple and effective process The program wizard function uses primer sequences or melting temperatures TM s to create a fully optimised program for your reactions using inbuilt primer algorithms All cycler s feature gradient functionality on all plate and tube format blocks 96 amp 384 OPCS a Progam Fast blocks ry Choose between standard and fast blocks e Ramp rate of up to 3 Cs with standard blocks e Ramp rate of up to 6 Cs with fast blocks e Increased productivity and faster protocols Fast blocks are made from solid silver with a gold fi
11. g rotor Output W 600 Power requirements Single phase AC 220 240 V 50 60 Hz 10A Timer 1 99 minutes in increments of 1 minute with a HOLD function continuous operation Programs 5 programmed operations possible speed run time acceleration deceleration settings and rotor stop signal Rotor stop signal Selectable from 5 melodies a beep tone and mute setting Acceleration braking time s 2 stage variable acceleration 2 stage braked deceleration and coasting deceleration Colour Sherbet silver Mint blue W x D x H mm 440 x 595 x 330 540 x 720 x 330 Weight kg 45 55 For typical life science applications especially in areas where biosafety is critical the VWR Collection presents the CT15 microcentrifuge CT15RE refrigerated model These are the fastest instruments on the market 21 500 x g with the highest capacity 24 x 1 5 2 0 ml and 0 5 ml and the lowest noise level lt 50dB A All this plus safety features such as door interlock dual overspeed detector imbalance detector abnormal motor temperature detector and automatic door closure system Overall a compact unit that is easy to use has a small footprint and a selection of auto clavable rotors for extra biological protection for PCR tubes and PCR strips CT15 RE Drive motor Brushless DC motor inverter control Max speed rpm 15 000 Max RCF g 21 500 Max capacity 24 x 1 5 2 0 ml and 24 x 0 5 ml when using T15A62 angle roto
12. ing chamber with grinding attachment 2mm sieve collecting tubes wooden stand for the tubes tool set Safety Lab Mixer MICROTRON MB 550 The MICROTRON MB 550 system S is Working volume attachments 125 250 500 1000 ml specially designed for mixing dispersing l hea eee homogenising emulsifying and size reduction nae site a el Power 550 W of materials Supply 230 V 50 Hz The MB 550 is available with four different Dimensions xH 190 x 250 mm attachments for volumes of 125 250 500 Weight drive unit only 4 6 kg 1000 ml A safety system prevents uncontrolled Attachments and safety covers have to be ordered starting and hence any personal injuries separately and are not supplied with the drive unit More Af Q KINEMATICA CH SN ue Dispersing and Mixing Technology Finest Swiss Made solutions VWR Equip Magazine Issue6 June 2008 SeQuUIP 4 Tuttnauer has been designing and manufacturing a wide range of sterilisation equipment for medical dental pharmaceutical biotechnology and laboratory applications from 7 5 to 17 000 litres for over 80 years The range of laboratory benchtop and vertical autoclaves includes models from 23 to 160 I for the sterilisation of e Liquids such as nutrient media and buffer solutions e Solid items such as pipettes tubes and filters e Glassware and plastic articles e Waste for disposal Rapid cooling option Integrated vacuum system e Op
13. ired by ASTM D1709 98 Available in 63 5 x 88 9 200 129 0026 clear or orange plastic with a temperature indicator Each bag imprinted 91 4 x 114 3 100 129 0027 with the universal biohazard symbol Bags with a temperature indicator have the words Contents Have Been n 3 Autoclaved printed in chemically active ink Before autoclaving the ink AUZ VAZ DP d a wW WWEiv is white After autoclaving is complete it darkens providing instant proof that biohazardous waste has been autoclaved SEeQUIP Essential innovations from VWR gt Refrigerated CentriVap Vacuum Concentrators These vacuum concentrators are designed to rapidly concentrate multiple heat sensitive samples such as RNA and proteins Centrifugal force combines with vacuum and controlled temperature to achieve fast results Protecting your MW laboratory environment Freeze drying and concentrating solutions from Labconco FreeZone 2 5 litre Freeze Dry Systems These compact lyophilisers are designed to handle light sample loads Freeze drying removes the moisture from samples while preserving their biological and chemical structure and activity Freeze dried samples do not need refrigeration and can be stored at ambient temperatures Features and Benefits e 2 5 litre collector capacity e Refrigeration system cools collector to 50 C for aqueous samples Cascade models have two refrigeration systems that reach 84 C for low eut
14. led climatic conditions qe To satisfy the many requirements and operating conditions facing global players today the new generation of the BINDER KBF series was fine tuned for increased peak performance even under unfavorable conditions and can operate under a wide range of different power supplies qe Differences in the quality of water used and more stringent environmental conditions in the operation of climatic chambers have a particularly bad effect on performance The new humidification system patent applied for can use water of any quality regardless of the source municipal water or stand alone from a canister without affecting performance This pressurised humidification system significantly improves humidity control The required humidity is metered into the climatic test chamber faster more accurately and with fewer germs than with any previous systems and is distributed homogenously throughout the interior without the need for high air recirculation Superheated steam spreads naturally in molecular form without major assistance from any equipment such as large air turbines In addition to a low noise level this also provides natural test conditions while avoiding the notorious fogging effect in the interior and with minimum risk of condensation on internal equipment surfaces or specimens gt gt Using this technology enables precise dehumidification at a dewpoint above 0 C eliminating the need for defrosting cycles a
15. ll of their performance and reliability W but are now also e Extra easy to maintain e Extra quiet e Extra energy efficient e Extra light Max pump capacity Ultimate vacuum total Ultimate vacuum total 50 60 Hz m h cFm without gas ballast mbar Torr with gas ballast mbar Torr 2x10 1x 10 7 1 5 x 107 1x 0 75 Description Plug version 2 Stage pump RZ 6 181 1126 2 Stage pump RZ 6 181 0152 2 Stage pump RZ 6 181 0153 vacuubrand VWR Equip Magazine Issue6 June 2008 SEeQuUIP Essential innovations from VWR Whisper quiet high speed performance The VWR collection proudly The CT6E CT6EL are some of the most environmentally friendly centrifuges around with energy saving operation bench top and micro It s very easy to use quickly reaches centrifuges with colour maximum speed of 6000 rpm and can be programmed for routine operations There s no doubt that this model will the performance and price become one of the great laboratory that are sure to grab the workhorses from the moment that you take it out of the box presents the new range of styling and most importantly attention Model Drive motor Brushless DC motor inverter control Max speed rpm 6000 angle rotor Speed control range rpm 300 to 6000 rpm in increments of 100 rpm Max RCF g 4770 angle rotor Max capacity 1000 ml 4x250 ml T5SS swing rotor 2000 ml 4x500 ml T3S6 swin
16. method Easy to produce and handle purified water should be free of ionic and organic contaminants Therefore most laboratories use ultrapure water systems or bottled water however these solutions vary greatly in their suitability for analytical analysis as important differences in quality can be observed Direct Q 3 UV system The easy to use Direct Q 3 UV system is designed to simplify life for small volume users who require from 2 10 of ultrapure Type I water per day Incorporating reverse osmosis deionisation UV and sterile filtration technologies the system guarantees the production of high quality ultrapure water directly from tap water The system also produces pure Type IlI water which is stored in an integrated reservoir and can be used in basic applications For ease of use the main purification technologies are contained in an innovative all in one pack The pack s plug and use design means that is ready for use in just a couple of minutes The system s colour graphic display enables users to see the product quality parameters and system status at a glance A superior alternative to bottled water As tap water cannot be used directly for analytical applications because of its high concentrations of ionic and organic contaminants bottled water or freshly produced ultrapure water from a system such as the Direct Q 3 UV system is generally used Organic contamination expressed as TOC Total Oxidisable Car
17. nd the displaying of optical density OD and temperature Results are shown on a bright LED display and may be printed via an RS232 interface A service menu provides access to span calibration where quartz compensation may be used when using quartz control plates Unlike some other polarimeters on the market that only take one single reading of the sample the ADP410 continually measures and displays the optical rotation offering the user a high level of confidence in the measurement being made e Dual scale e Simple operation e Jemperature sensor Range 90 to 90 225 to 225 e ED Interference filter 589 3nm Resolution 0 01 0 01 Accuracy 0 02 0 05 RFM300 Refractometers with Peltier New temperature control for industrial applications For Over 15 years the RFM340 refractometer has become the bench mark in refractive index and Brix measurement within the industrial manufacturing sector In 2007 Bellingham Stanley Ltd launched replacement models that surpass the operational features of the earlier instruments whilst retaining the simple to use philosophy and factory friendly construction The new models have a number of additional benefits that enhance the world leading marque The sample is presented to the artificial sapphire prism housed in a very flat easy to clean dish Replacing the presser instigates the reading whilst the Peltier temperature control with an intelligent thermal management system ensures that the re
18. nd the resulting fluctuations in humidity Improved controllability of the pressurised steam humidification system combined with optimised refrigeration control and improved sealing results and additional capacity reserves even at elevated environmental conditions up to 32 C The improved sealing was achieved by a redesign which resulted in only one outer door for the model KBF 240 in conjunction with the new inner glass door which now has a separate seal These measures have produced high reliability and long term stability for a temperature range from 10 to 100 C dry or 10 C to 90 C 10 90 RH THE NEW KBF 240 AT A GLANCE e Absolute compliance with standards for all relevant guidelines e Independent of water quality e Precise long term stability for temperature and humidity e Extremely fast humidification after opening door e ICH compliant illumination for photostability tests gt BINDER VWR Supplier Partnerships for Customer Solutions Want to know more Please tick off the articles that are of interest to you and fax to your local VWR sales office see below or email with the title Equip information required Page No Article Tick for more information 3 Kinematica products B 4 Tuttnauer autoclaves E 5 Ebro autoclave validation E 5 VWR Collection autoclave bags E 6 Labconco freeze dryers m 7 Vacuubrand rotary vane pumps z 8 VWR Collection bench and micro centrifuges E 9 Millip
19. nised by the lift automatically to prevent any possibility of breaking the glassware To ensure that you get great results every time the unit features movement from left to right and right to left in intervals you can adjust for an efficient drying process Other features include e Timer function for time lapse controls Speed range from 20 to 270 rpm Smooth start from 100 rpm Digital speed display Cooling surface 1 200 cm Push off mechanism to loosen tightly fitting flasks Cat No EU plug Cat No UK plug Cat No CH plug 531 0295 531 3406 531 3407 531 0289 531 3430 531 3437 531 0294 531 3408 531 3409 531 0288 531 3438 531 3439 RV 10 basic V with vertical glassware RV 10 basic V C with vertical glassware coated RV 10 basic D with diagonal glassware RV 10 basic D C with diagonal glassware coated RV 10 digital V RV 10 digital V C RV 10 digital D RV 10 digital D C e Properties as RV 10 basic V with the following additional functions e Digital water oil heating bath with integrated carrying handles e Temperature control of the heating bath by a micro controller e Digital temperature display e nfrared interface for data transfer from the heating bath to the drive unit e RS232 interface for PC remote operation with labworldsoft e Automatic operation with labworldsoft Cat No EU plug Cat No UK plug Cat No CH plug 531 0293 531 3410 531 3417 531 0287 531 3440 531 3447 531 0292 531 3418 53
20. nish by an electroplating process that reduces the thermal mass of the block All of the blocks can be interchanged and swapped within seconds SBAERAG pagg The Gumeni Program ts vaid Run Time 00 13 0a Save ms Each thermal block has 4 independent temperature control sensors and 8 peltier heating units that ensure accurate heating and cooling control and unsurpassed uniformity across the block surface factors that are vital to superb thermal cycling performance All cyclers contain the Active Sample Cooling ASC function that cools your sample until the heated lid reaches its target temperature This feature reduces non specific primer binding and extension Cancel Multiple sensor technology Automated power lids Duo and QuattroCycler As a standard feature these cyclers have fully independent and automated heated power lids If your application is within a standard lab or if you are looking to integrate into robotics they are the perfect choice Automated power lids provide uniform pressure to plates and tubes every time ensuring reproducibility of factors within experiments Quality assured e NIST UKAS traceable calibration procedures e Password control allows access to various reports e Administrator user and guest levels enable programs to be written edited protected and run according to status e Power failure options continue or halt e Barcode reading option e Encrypted GLP documentation p
21. o the high sales volume of promoted articles some items may be temporarily out of stock VWR Terms and Conditions of Sale apply VWR Equip Magazine Issue6 __SEQUIP Welcome to this June edition of equip reaching you we hope as summer is truly beginning This edition is packed with new products featuring the latest innovations in the world of scientific instrumentation A bumper selection from our VWR Collection includes thermal cyclers and gel documentation systems for Life Scientists as well as the brand new bench centrifuges with performances as funky as their colours The great value for money IKA rotary evaporators are exclusive to VWR and provide a excellent alternative choice for chemists Labconco are welcomed into the VWR European portfolio with their first entry in the equip magazine We hope you enjoy reading our latest selection our celebration for the coming of midsummer Best Wishes The VWR equip team State of the art homogenising mixing and milling with Kinematica Tuttnauer autoclaves designed to perform Easy autoclave validation from Ebro VWR Collection autoclave bags Freeze drying and concentrating solutions from Labconco Vacuubrand s new rotary vane pumps VWR Collection brand new benchtop centrifuges Ultrapure and pure water the easy way with Millipore Sfofofifafufulatu Make your own hydrogen and nitrogen with VWR Schmidlin A complete range of gel documentation system
22. ore Direct Q 3 UV system a 10 VWR Schmidlin gas generators Bi 11 VWR Collection gel documentation system E 12 VWR Collection thermal cyclers Ei 13 ADP410 polarimeter and RFM300 refractometer from Bellingham Stanley i 14 IKA rotary evaporators m 15 Binder KBF constant climate chambers E Tick here if you would like to register for our monthly email newsletter packed full of offers and news E Please complete in block capitals Country Name Postcode Company lnstitute E mail Department Telephone number Address Fax number Your local contact VWR International GmbH Export Department Graumanngasse 7 A 1150 Vienna AUSTRIA Have you got your copy of the VWR catalogue Order your free copy online http ru vwr com English http cz vwr com Phone 43 1 97002 640 http hu vwr com Fax 43 1 97002 276 p http pl vwr com E mail export at vwr com http si vwr com Web www vwr com http sk vwr com Country Phone number Website Croatia 43 1 97002 203 info hr vwr com si vwr com Czech Republic 420 222 363 481 info cz vwr com czZ vwr com Hungary 36 1 786 65 13 info hu vwr com hu vwr com Poland 43 1 97002 245 info pl vwr com pl vwr com j Slovakia 421 2 321 010 33 info sk vwr com sk vwr com a Slovenja 43 1 97002 203 info si vwr com si vwr comsi
23. r Output W 500 Power requirements AC 220 240 V 10 50 60 Hz 10 A AC 220 230 V 10 50 Hz 10 Timer 1 99 minutes in increments of 1 minute with a HOLD function continuous operation Programs SPEED RCF TIME TEMP CT15RE only ACCEL DECEL and stop melody Memory Up to 3 sets of operating parameters can be stored Temperature C Se 20 40 Acceleration braking time s 2 stage variable acceleration 2 stage braked deceleration plus free deceleration W x D x H mm 290 x 520 x 300 Weight kg 17 40 VWR Equip Magazine Issue 6 June 2008 For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip Ultrapure and pure water the easy way tar References and literature Kleefisch G Weber C Pharm Ind 69 No 6 735 738 2007 Direct Q 3 system User Manual Millipore Corporation Direct Q 3 UV specifications for Type product water Resistivity 18 2 Ohm cm 25 C TOC lt 5 ppb Particulates lt 1 particulate ml Pyrogens lt 0 01 Eu ml with Biopak ultrafilter Flow rate gt 0 5 I min 4 For analytical applications the specifications of instruments as well as the purity of reagents and media are constantly on the rise The role of water as a reagent is a key factor when it comes to ensuring the results and reproducibility of an analytical
24. roduced with every program run Description Cat No UnoCycler Thermal Cycler chassis requires 1 block to be ordered separately 96 or 384 format 732 1200 DuoCycler Thermal Cycler chassis requires 2 blocks to be ordered separately 96 or 384 format 732 1201 QuattroCycler Thermal Cycler chassis requires 4 blocks to be ordered separately 96 or 384 format 732 1202 96 well gradient block 732 1203 384 well gradient block 732 1204 96 well fast gradient block 732 1205 384 well fast gradient block 732 1206 in situ block 732 1207 Issue 6 June 2008 VWR Equip Magazine For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip Applications Low cost automatic polarimeter for industrial applications The ADP410 digital polarimeter is ideally suited for use in applications that do not require the highest level of accuracy or demand stringent data control such as that offered on some of the higher priced polarimeters on the market Offering dual scales with temperature correction the ADP410 is ideal for use in the sugar confectionery chemical and in some instances the pharmaceutical industry The ADP410 is also used extensively in academia Operation is very simple by way of four graphically identified push buttons including scale and compensation selection zero calibration a
25. s from the VWR Collection 11 The next generation in thermal cycling technology from the VWR Collection 12 ADP410 polarimeter and RFM300 refractometers from Bellingham Stanley 13 Unique rotary evaporators from IKA 14 is Binder KBF constant climate chambers 15 June 2008 For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip Essential equipment State of the art for homogenising mixing and milling High quality equipment from KINEMATICA for sample preparation and applications in the lab Benchtop Homogeniser POLYTRON PT 3100 D The POLYTRON PT 3100 D dispersing Working volume 0 1 4000 ml homogenising and mixing system has been Speed range 300 30 000 min equipped with a complete new and intelligent amp mm dispersing E paces control system to ensure user safety at both a oe sale eel ser interface LCD with foil keyboard constant speed level and when the load Pawar 1200 W changes Supply 230 115 V 50 60 Hz A new user interface with foil keyboard and Noise level w o load lt 75 dB A LCD for displaying different process parameters Dimensions LxWxH 240 x 130 x 265 mm has been incorporated Three possible operation Weight drive unit only 3 8 kg modes can be chosen for manual Standard Software for control via PC and RS232 interface semi automatic Tim
26. stems This broad complete range provides a solution to every need The GENOPLEX systems are available in a range of standard configurations for all fluorescence and chemiluminescence applications You can choose from models featuring the very latest high resolution CCD cameras for use in general gel documentation or the more advanced specification units for chemiluminescence work Motor driven lenses are standard to both systems and you get the choice of selecting either manual or computer driven filter selectors and a range of lighting options for both reflected and transmitted light applications The camera lenses lighting and darkroom functions are computer controlled GenoSmart The new GenoSmart gel documentation system from VWR makes analysis and documentation of your DNA and protein gels very easy By simply transferring the data on to a USB stick you can work with your images on a separate PC without blocking the gel documentation system for other users Also supplied with versatile GenoSoft analysis software Wavelength Cat No nm 730 3004 730 3005 730 3006 730 3008 730 3009 730 3010 Features e Cost effective quality digital imaging e High resolution camera e Flexibility to add hardware and software e Innovative mini darkroom option e Programmable and reproducible capture settings e Real time imaging using your PC or Mac Special introductory prices on the GenoSmart model in the
27. sult is only given when both the temperature and sample are stable The results are shown on the display and may be printed sent to LIMS and or up to 700 may be stored within the instrument memory for later extraction The METHODS system allows rapid configuration of measurement parameters typically only two button presses are required to change scale compensation type stability check type operating tem perature etc Additionally citric acid correction values or product offsets can be set independently to product types types facilitating use in beverage packaging plants amongst other applications A e Multiple language on screen menu PIN system protects instrument settings from misuse in factory environments and an optional e RI Brix and user scales Enhanced Protection Pack ensures moisture and dust can not penetrate the instrument systems e Rapid temperature stabilisation Two special models are also available that enable use where harsh solvents are involved such by Peltier device as those in the edible oil resin adhesive and chemical industries e Automatic READ when sample presser placed on prism e Rapid configuration of instrument Specifications RFM330 RFM340 by METHODS system Seales e Reading offset method Refractive Index 1 32 1 58 0 100 e Citric acid correction method Sugar Brix 0 100 0 100 e 700 stored readings e lined o s d e PIN protection amp GLP printout E ni e Sugar Brix 0 00001 0 01 ae N 0 0001 0
28. technology ensures long uninterrupted operation since there is no need to replace drying cartridges N MISTRAL LCMS Nitrogen made directly in the laboratory The Mistral LCMS is designed to meet or exceed the nitrogen requirements of all types of LCMS systems The proven hollow fibre membrane technology combined with a sophisticated dual compressor and fibre management system guarantees smooth operation for over 8000 hours This bench space unit which fits easily underneath a laboratory desk produces nitrogen with a purity of gt 98 at a flow rate of up to 35 litres min and a pressure of 8 bar N MISTRAL O Nitrogen made directly in the laboratory For labs with an existing central compressed air supply there is the MISTRAL O that works pneumatically and does not require power Simply connect to the compressed air supply line and depending on the inlet pressure nitrogen with 5 11 bar and a purity of gt 98 can be produced Flow rates are between 25 and 60 litres min depending on the model Models for other applications are available Please contact your local VWR sales office VWR Equip Magazine Issue6 June 2008 GenoPlex and GenoPlex Chemi For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip Applications The VWR Collection introduces a complete range of gel documentation sy
29. tional integratable printer e Process documentation software e Stainless steel wire baskets and containers and more VWR Equip Magazine Issue6 Air exhaust filtration Bio Safety Level 2 Designed to perform Standard features of the Tuttnauer laboratory autoclaves Microcomputer control system for highly reliable and safe operation 6 individual programmes Pressure temperature time and any faults registered on LCD or LC display ss Sterilisation temperature time freely selectable vga between 105 and 138 C and 1 99 minutes respectively PT 100 temperature sensor in a reference vessel ensures set sterilisation temperature is actually reached during the cycle De mineralised water level automatically regulated Exhaust steam cooled down before leaving the autoclave Heat resistant plastic covering on lid prevents operator contact with hot parts and protects from burning Temperature and pressure regulated guaranteeing an absolutely safe sterilisation procedure Validation ports for external temperature sensors Pre prepared for fitting a printer RS232 interface The safety aspects prevention is key Pressure dependent door lock prevents the door from being opened when under pressure Temperature dependent door lock works in conjunction with temperature control in a reference to prevent the door from being opened until the temperature is below a specified level thereby preventing d
30. to 10 mbar have to be achieved reliably VACUUBRAND rotary vane pumps are compact one or two stage oil sealed rotary vane pumps with integrated oil pump and gas ballast for high vapour tolerance Their exceptionally high performance and flexible accessories can be used for a wide range of applications in laboratories and factories One important application is freeze drying and the RZ 6 is the ideal pump to combine with a freeze dryer to get outstanding results Advantages e High conductance coefficient high pumping speed even at low vacuum levels e High vapour tolerance for water and solvents due to large gas ballast quantities of up to 10 of the pumping capacity e Excellent ultimate vacuum even with gas ballast e Anti corrosion protection on shutdown due to vacuum tight oil circuit to prevent corrosive gases or oil contamination from entering the pump module e New oil circuit and large oil volume for longer service intervals e Compact design very small dimensions light weight and easy maintenance due to telescopic design Package ready for use with your freeze dryer 2 stage pump RZ 6 with oil mist filter and VS 16 butterfly valve For more information on these products complete the faxback enquiry form on the back cover and send to your local VWR sales office or visit our website www vwr com and click on equip New rotary vane Pumps XS VACUUBRAND s new rotary vane one and two stage rotary vane pumps XS keep a
31. und applications in GC leads to shorter analysis times and higher e Carrier gas in gas chromatography GC chromatographic and other sensitivities e Blanket gas wherever an oxygen free e GC detector fuel gas for e g FID NPD ECD FPD atmosphere is required e Reactor gas e Combustion plasma chambers laboratory techniques The advantages are clear Producing your own gases is cheaper than buying in and you don t have to bear the extra costs of Storage and transport as you can make what you want when you want it There is no potentially dangerous handling of gases under high pressure and on line generation means that the flow of clean gas is uninterrupted because there is no potential of the contamination you can sometimes get when changing gas bottles Gas generators can be placed next to instruments like LCMS or GC because they do not contain hazardous quantities of high pressure gas A hydrogen gas generator for example has an internal volume of lt 40 ml of hydrogen This makes gas generators very safe and easy to handle Schmidlin VWR are pleased to announce a new range of generators N NM H gt Generator Hydrogen made directly in the laboratory The NM range produces a continuous flow of clean hydrogen with a purity of gt 99 9999 up to 10 5 bar and with flow rates between 100 ml min and 1000 ml min No aggressive chemicals are needed just distilled water and the exclusive no maintenance auto drying

Download Pdf Manuals