Home
1756HP-CELL User Manual v1.00.08
Contents
1. Coverage The most important factor is getting service in the areas you will be using your phone Upon viewing competitors coverage maps you may discover that only GSM or CDMA carriers offer cellular service in your area If so there is no decision to be made but most people will find that they do have a choice Data Transfer Speed With the advent of cellular phones doing double and triple duty as streaming video devices podcast receivers and email devices speed is important to those who use the phone for more than making calls CDMA has been traditionally faster than GSM though both technologies continue to rapidly leapfrog along this path Both boast 3G standards or 3rd generation technologies EVDO also known as CDMA2000 is CDMA s answer to the need for speed with a downstream rate of about 2 megabits per second though some reports suggest real world speeds are closer to 300 700 kilobits per second kbps This is comparable to basic DSL As of fall 2005 EVDO is in the process of being deploved It is not available everywhere and requires a phone that is CDMA2000 ready GSM s answer is EDGE Enhanced Data Rates for GSM Evolution which boasts data rates of up to 384 kbps with real world speeds reported closer to 70 140 kbps With added technologies still in the works that include UMTS Universal Mobile Telephone Standard and HSDPA High Speed Downlink Packet Access speeds reportedly increase to about 275 380 kbps This techno
2. A PIN number is required to operate the SIM card contact your cellular service provider if PIN is unknown or problem PUKRequired The PUK number will be required when the PIN number has been entered incorrectly three times Please remove SIM card from the module and enter the correct PUK and new PIN from a cellular phone GSMError There is an error with the GSM network or mobile equipment TextMSGPending A text message SMS has been received by the module and is ready to be read by the controller ClientMode When an APN is set the CELL module will try to connect to a network The module has also connected to another TCP IP server and is acting as a client ServerMode The module has connected to an accessible APN and has started in server mode default Hiprom Technologies 6 7 2011 SIM has no error SIM has error either communicating or no SIM present PIN number is OK or no pin required PIN number is required check PIN entered into the config image PUK not required PUK is required remove SIM No error GSM communications is OK GSM error check mobile equipment No text messages Text message available to be read by the controller Module will is not set as Client Module will be set as Client Module is not set as the Server Module is set as the Server 11 pri ae SignalStrength The received signal strength on the GSM network given as a max of 99 minimum of 0 ServicePro
3. information lt GSM SMA connector 1756HP CELL Front View LED and LCD information All information regarding the module status cellular operator signal strength APN IP address etc will be given via the LCD and LED indicators Please view Module Status section for more information GSM SMA Connector This connector is used to connect the supplied GSM antenna The installation of this antenna will be explained later in this section Hiprom Technologies 6 7 2011 SIM card slot 4 DIP switches 1756HP CELL Top View SIM card slot The SIM card must be inserted into the module with the metallic surface towards the PCB side and the triangle corner cut off towards the front and the top of the module The PIN number if assigned for the SIM card must be entered into the Config Image for successful operation NOTE If the SIM card requires a PIN and the user failed to enter the correct PIN in the Config Image the SIM card will be locked and the user will need to unlock it using the PUK code DIP switches These are used to select certain general operation options for the module The settings will be explained in the Module Configuration section Software The user will need the following software to configure and use the 1756HP CELL e RSLogix 5k ladder example code e Future Add on Profile AOP Both the applications can be found on the product CD or the Hiprom Technologies website www hiprom co
4. 112 113 DESCRIPTION phone failure no connection to phone phone adaptor link reserved operation not allowed operation not supported PH SIM PIN required PH FSIM PIN required PH FSIM PUK required SIM not inserted SIM PIN required SIM PUK required SIM failure SIM busv SIM wrong incorrect password SIM PIN2 required SIM PUK2 required memory full invalid index not found memory failure text string too long invalid characters in text string dial string too long invalid characters in dial string no network service network timeout network not allowed emergency calls only network personalization PIN required network personalization PUK required network subset personalization PIN required network subset personalization PUK required service provider personalization PIN required service provider personalization PUK required corporate personalization PIN required corporate personalization PUK required unknown Illegal MS 3 Illegal ME 6 GPRS services not allowed 7 PLMN not allowed 11 location area not allowed 12 roaming not allowed in this location area 13 Hiprom Technologies 6 7 2011 132 133 134 149 150 148 151 152 153 154 155 156 157 158 159 160 161 162 300 301 302 303 304 305 310 311 312 313 314 315 316 317 318 320 321 322 330 331 332 340 500 Hiprom Technologies 6 7 2011 service option not supported 32 requested service option not
5. Hiprom Technologies 6 7 2011 USER MAN UA L Section Page INTRODUCTION 2 INSTALLATION 3 HARDWARE 3 SOFTWARE 4 SETUP 5 HARDWARE 5 RSLOGIX 7 OPERATION 10 HIPROMCELL RSLOGIX 10 SENDING A TEXT MESSAGE 14 RECEIVING A TEXT MESSAGE 14 GSM OR CDMA EVDO 15 SPECIFICATIONS 17 ELECTRICAL 17 MECHANICAL 19 APPENDIX 20 A DISPLAY STATUS 21 B MESSAGE BLOCKS 23 C ERROR CODES 24 Hiprom Technologies 6 7 2011 INTRODUCTION The 1756HP CELL module provides a method of sending text messages to either a user s mobile phone or another 1756HP CELL module which will allow communication between multiple PLCs Messages are sent over a GSM network to a cellular number of another SIM card used by a mobile phone CELL module etc Sufficient network reception is required for successful SMS communication The connectivity of the modules will be limited by the GSM network reception in the deployment area This document serves to describe the functionality installation configuration and operation of the module NOTE The Connection parameters and configuration images are only valid for firmware version 1 01 02 onwards Please see User Manual v1 00 07 for details Hiprom Technologies 6 7 2011 INSTALLATION Hardware The 1756HP CELL module is designed to operate within the Allen Bradley ControlLogix platform All power required for the module s operation is derived from the ControlLogix backplane LED and LCD status
6. Module Properties Local 3 1756 MODULE 1 1 General Connection Module Info Backplane Type 1756 MODULE Generic 1756 Module Parent Local Connection Parameters Assembly SIZE Mame Pell Slot Input jal 32 bit Description 1756HF CELL gsm communication Output T 32 bit device Configuration 18 bit Comm Format Data DIN pe E Slot Status Offine RR The user must copy the CELL _ CONFIG UDT as given in the example code to the Config Image of the module Please refer to the example code KA mma 7 Hiprom Technologies 6 7 2011 CELLO Config A fieq CELL_CHFG_IMAGE CELLO Config PIN_HUMEER STRINGS CELLO Config SMS_SERY_ CENTRE aa STRINGIE CELLO Conhig amp PH STRING 24 CELLO Contig PORT MID STRINGS CELLO Config MODE SELELT STRINGS CELL Config PIN NUMBER This is the pin number for the SIM Eg card inserted into the module May 1234 be left blank if PIN is disabled on the SIM card CELL Config SMS SERV CENTRE The service centre that is used bv the service provider to send and receive SMS messages Eg Vodacom SA 27829129 MTN SA 27831000002 CELL Config APN If an APN has been registered with Eg i www hiprom co za the cellular service provider to obtain d a static IP address it may be arca entered here or left blank CELL Config PORT Eq The TCP IP port used by the module ie when establishing a TCP server or left blan
7. TE IN future revisions of the CELL module GPRS 3G will be used with client server modes based on TCP IP This will be advantageous as it is a cheaper and faster alternative to SMS messaging Hiprom Technologies 6 7 2011 GSM or CDMA EVDO NOTE The CELL module uses mobile equipment that operates on the GSM network The CELL module will not operate on a CDMA network In cellular service there are two main competing network technologies Global Svstem for Mobile Communications GSM and Code Division Multiple Access CDMA Cellular carriers including Sprint PCS Cingular Wireless Verizon and T Mobile use one or the other Understanding the difference between GSM and CDMA will allow vou to choose a carrier that uses the preferable network technology for your needs The GSM Association is an international organization founded in 1987 dedicated to providing developing and overseeing the worldwide wireless standard of GSM CDMA a proprietary standard designed by Qualcomm in the United States has been the dominant network standard for North America and parts of Asia However GSM networks continue to make inroads in the United States as CDMA networks make progress in other parts of the world There are camps on both sides that firmly believe either GSM or CDMA architecture is superior to the other That said to the non invested consumer who simply wants bottom line information to make a choice the following considerations may be helpful
8. correctly more than three times Please remove the SIM card and enter a valid PUK number from within a cellular mobile telephone e Debug Mode When the correct DIP switch has been set the module will be in debug mode The user must never put the module in debug mode e Safe Mode When the safe mode jumper has been set the module will be in safe mode This means that the module has booted from the code that it was shipped with Hiprom Technologies 6 7 2011 APPENDIX B MESSAGE BLOCKS Send a text message SMS Below is the structure of the message block Message settings Message Type CIP Generic Service Type Custom Service Code 32h Class 72h Instance 01h Attribute 01h Date elements Source Element Cell SMS Sending NUMBER LEN Source Length 108 Destination blank Refer to the example code Read a text message SMS Below is the structure of the message block Message settings Message Type CIP Generic Service Type Custom Service Code 32h Class 72h Instance 02h Attribute 01h Date elements Source Element blank Source Length 0 Destination Cell SMS Received NUMBER LEN Refer to the example code NOTE A message must only be read when the TextMSGPending bit is set from the Input image Please refer to sample project APPENDIX C Error Codes Error O O1 R ND N 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 30 31 32 40 41 42 43 44 45 46 47 100 103 106 107 111
9. ell as GSM carriers and though they may contract with GSM cells for roaming in more rural areas the charge to the customer will generally be significantly higher International Roaming If you need to make calls to other countries a GSM carrier can offer international roaming as GSM networks dominate the world market If you travel to other countries you can even use your GSM cell phone abroad providing it is a quad band phone 850 900 1800 1900 MHz By purchasing a SIM card with minutes and a local number in the country you are visiting you can make calls against the card to save yourself international roaming charges from your carrier back home CDMA phones that are not card enabled do not have this capability however there are several countries that use CDMA networks Check with your CDMA provider for your specific requirements SPECIFICATION Electrical specification Power Requirements Power Consumption Operating Temperature Storage Temperature Relative Humiditv Operating Shock Storage Shock Vibration Emissions ESD Immunitv Radiated RF Immunitv EFT B Immunitv Conducted RF Immunitv Enclosure Tvpe Rating Cable specification Tvpe Impedance Capacitance Shield Connectors Hiprom Technologies value All power is derived from the 1756 backplane 0 to 50 C 0 to 50 C 5 to 95 non condensing IP20 value RG 175 or equivalent 50 Ohm 16 5 pF foot 54 1 pF meter Foil or copper braid 100 co
10. in RSLogix5000 The module must be configured before it can be successfully used See also No Operator e Booting CELL The above is an example of the message that will scroll across the LCD while the module is booting its mobile equipment ma pr d 21 Hiprom Technologies 6 7 2011 e 1756HP CELL A Rev 1 01 02 This will show the revision of the firmware on the module Will be displav once when powered on e VodaCom SA The above is an example of an Operator ID that will scroll across the LCD e No Service Provider Name The above is an example if no cellular operator name has been acquired This will also be displayed in conjunction with CNFG if the module has not yet been configured e Signal is 77 The above is an example of the received network signal strength e 3G selected The above is an example of the network modulation scheme in operation that will scroll across the LCD e APN IP 192 168 1 100 The above is an example of an IP address that will scroll across the LCD Note this is only relevant to the APN that the module is connected to internallv in the GSM network e RST This will be displaved if the module has received a reset CIP command The module is in reset e SIM There is no SIM card in the module Remedy by inserting a valid SIM card in the module e PIN The PIN for the SIM card is invalid Please check and re enter PIN in the config parameters in RSLogix5000 project e PUK The PIN has been entered in
11. k CELL Config MODE SELECT The mode can be manually selected so that the module will use 13 to select GSM GPRS EDGE or 14 to use 3G Using 2 will result in Automatic selection 2 Automatic 13 GSM GPRS EDGE 14 3G WCDMA NOTE Config and SMS data and numbers are entered in ASCII format note the STRINGx data type To enter data see the following steps CELLO Config oa CELL_CNFG_IMAGE CELLO_Config PIN_NUMBER osi STRINGE CELLO Config SMS_SERV_CENTRE 27829129 STRING16 CELLO Config AFN D STRING24 IF CELLO Config PORT D STRINGS CELLO_ Config MODE_SELECT 13 fad STRINGS A pa pre od 8 Hiprom Technologies 6 7 2011 it String Browser CELL_Config PIN_NUMBER Position 4 Count 4 of 8 Errors pe _ Ta Cancel Apply Help CELLO Config i CELL CNFG_IMAGE CELLO Config PIN_ NUMBER i H STRINGS CELLO Config 55 SERV CENTRE 427829129 INN l STRINGIE CELLO Lonha APN STRING24 CELLO Conhg PORT z STRINGS CELLO Config MODE SELELT 13 MM l STRINGS Hiprom Technologies 6 7 2011 OPERATION RSLogix Each 1756HP CELL consumes 1 connection from the Logix Controller Name A Value F orce Mask n Style Data Type Cell Input 5 CELL_INPUT Cell Input CommStatuz O Decimal DINT Lell Input kiodulelIE Decimal BOOL Lell Input SIME rror O Decimal BOOL Cell Input PIN Required O Decimal BOOL Ce
12. ll_Input PUKRequired 0 Decimal BOOL Cell Input GSMError 0 Decimal BOOL Cell_Input TextMSGPending 0 Decimal BOOL Cell_Input ClentMode O Decimal BOOL Lell Input serverade O Decimal BOOL d Lell Input SignalStrength 0 Decimal SINT Cell Input ServiceProvider ul EA STRING24 Cell Input TEST anal SE LELL TEXTSERWI Cell Input TERT MSGPendingCountk O Decimal SINT CellInput GSM iena PRI CELL_GSMSERWIC Cell_Input GSM noService 0 Decimal BOOL Cell Input GSM GSM 0 Decimal BOOL Cell Input GSM GPRS O Decimal BOOL Cell Input GSM EDGE O Decimal BOOL Lell Input GSM WCDMA 0 Decimal BOOL Cell_Input GSM HSDP 0 Decimal BOOL Cell Input GSM HSUPA 0 Decimal BOOL Cell_Input GSM HSP O Decimal BOOL CellInput GSM APN_IPAddress lid i STRINGIE Cell Input GSM ErrorLode 0 Decimal INT Cell Input Reserved Decimal DINT INPUT IMAGE The user must copy the Input Image of the module to the CELL_INPUT UDT as given in the example code Please refer to the example code CommStatus This is reserved This is reserved ModuleOK This indicates that the module 0 There is an error on the module has booted and all hardware is 1 Module is OK operations may continue functioning A af pe di 10 SIMError This will be active if there is an error in communicating with the inserted SIM card This will also be active if no SIM has been inserted in the module PINRequired
13. logy is also known as W CDMA but is incompatible with CDMA networks An EDGE ready phone is required In the case of EVDO theoretical high traffic can degrade speed and performance while the EDGE network is more susceptible to interference Both require being within close range of a cell to get the best speeds while performance decreases with distance ass 16 Hiprom Technologies 6 7 2011 Subscriber Identity Module SIM cards In the United States only GSM phones use SIM cards The removable SIM card allows phones to be instantiv activated interchanged swapped out and upgraded all without carrier intervention The SIM itself is tied to the network rather than the actual phone Phones that are card enabled can be used with anv GSM carrier The CDMA equivalent an R UIM card is only available in parts of Asia but remains on the horizon for the U S market CDMA carriers in the U S require proprietarv handsets that are linked to one carrier only and are not card enabled To upgrade a CDMA phone the carrier must deactivate the old phone then activate the new one The old phone becomes useless Roaming For the most part both networks have fairly concentrated coverage in major cities and along major highways GSM carriers however have roaming contracts with other GSM carriers allowing wider coverage of more rural areas generally speaking often without roaming charges to the customer CDMA networks may not cover rural areas as w
14. m ass 4 Hiprom Technologies 6 7 2011 SETUP Hardware DIP switches The switches are numbered as shown below 1234 JJNPOW JO JUOJ H Switch Description This is used for debugging the module The user must never set this This is reserved for future use This is reserved for future use This is reserved for future use BR NN Hiprom Technologies 6 7 2011 SAFE MODE The module has the option to run the firmware that it was originally shipped with This can be used in a case where the power was cycled whilst flashing the firmware Thus if the module does not boot because of the corrupted firmware the user can set the module into safe mode and re flash the module The safe mode jumper is located under the front cover as shown below A NOTE The module must be placed back into non SAFE MODE to avoid running old firmware even if the module has been flashed with new firmware HIPROM CELL SAFE MODE JUMPER Hiprom Technologies 6 7 2011 RSLogix This section describes the procedures required to configure the 1756HP CELL module within the Logix platform The user must select the Generic 1756 Module in RSLogix when adding the module to the IO tree in RSLogix 5k Module Description Vendor Analog Communications Controllers Digital Drives Motion Other 1756 MODULE Generic 1756 Module Allen Bradley Specialty F The following assembly parameters must be used for the module M
15. ownload of data GSM APN IPAddress This is the IP address Example obtained after connection to IP Address the APN has been 492 135 145 007 192 135 145 007 established Note this is an Ascii string GSM ErrorCode When an error is 0 No error has occurred experienced the error code XXX Please see Appendix C for relevant error codes will be displayed in an INT Reserved reserved reserved OUTPUT IMAGE The output image is not used in the CELL module Hiprom Technologies 6 7 2011 Sending a Text message SMS In order to communicate with another CELL module or to send a notification an SMS must be sent See the Appendix B Message Blocks on how to set the custom message to be able to send an SMS Name Value se orce Mask Style Data Type l LELL SMS PRE CELL_SMS CELL SMS Receved i ni l SMS CELL 5M5 Hecemed NUMBER hl lee STRINGIE CELL SMS Recerved DATA hal REI STRINGIEO CELL SMS Sending i l SMS CELL_SM5 Sending NUMBER i l STRINGIE CELL_SM5 Sending DATA l STRINGIEO The user must copy the Input Image of the module to the CELL INPUT UDT as given in the example code In Cell SMS Sending NUMBER the number entered is in ASCII format and must be preceded by the character along with the international country code eg for South Africa 27XX XXX XXXX or for United Kingdom 44XX XXX XXXX etc For the text message Cell SMS Sending DATA is populated with the desired data in A
16. scii format The current maximum length of the text message sent to and from the CELL module is 160 characters long To see ladder logic for sending an SMS please refer to the example code Receiving a Text message SMS Name Value F orce Mask Style Data Type LELL 5M5 LELL 5M5 CELL SMS Recelved er SMS CELL_SMS Recetved NUMBER i ree STRINGIE CELL SMS AReceved DATA Sh STRINGIEO CELL_SMS Sending E or SMS CELL_SMS Sending NUMBER jal fais STRINGIE CELL _SM5 Sending DATA ai RR STRINGIEO In order to communicate with another CELL module or to receive an SMS the CELL module must be requested for the pending SMS See the Appendix B Message Blocks on how to set the custom message to be able to receive an SMS An SMS can only be read if there is an SMS pending notified by TextMSGPending in the Input Image This is the sender of the SMS is Cell SMS Received NUMBER the number populated is in Ascii format and is preceeded by the character along with the international country code eg for South Africa 27XX XXX XXXX or for United Kingdom 44XX XXX XXXX etc fs g 14 Hiprom Technologies 6 7 2011 For the received text message Cell SMS Sending DATA is populated with the desired data in Ascii format The current maximum length of the text message sent to and from the CELL module is 160 characters long To see ladder logic for receiving an SMS please refer to the example code NO
17. subscribed 33 service option temporarily out of order 34 PDP authentication failure invalid mobile class unspecified GPRS error VBS VGCS not supported by the network no service subscription on SIM no subscription for group ID group ld not activated on SIM no matching notification VBS VGCS call already present congestion network failure uplink busy no access rights for SIM file no subscription for priority operation not applicable or not possible ME failure SMS service of ME reserved operation not allowed operation not supported invalid PDU mode parameter invalid text mode parameter SIM not inserted SIM PIN required PH SIM PIN required SIM failure SIM busy SIM wrong SIM PUK required SIM PIN2 required SIM PUK2 required memory failure invalid memory index memory full SMSC address unknown no network service network timeout no CNMA ack expected unknown error Hiprom Technologies 6 7 2011 HIPROM mg TECHNOLOGIES HIPROM TECHNOLOGIES TEL 27 11 787 4458 FAX 27 11 787 7937 POSTAL P O Box 732 Pinegowrie South Africa 2123 PHYSICAL 369 Pretoria ave Ferndale Randburg South Africa
18. verage SMA module side 6 7 2011 Hiprom Technologies 6 7 2011 Signal attenuation lt 10 dB 100 feet for cable and connectors Antenna specification value Dimensions 3 05 D x 2 61 H 77 5mm x 66 2 mm Weight 6 0 oz 170 grams Connector SMA module side Mounting Magnetic Shark fin antenna Hiprom Technologies 6 7 2011 Mechanical 1099 NOYdIH 1139 dH9621 Hiprom Technologies 6 7 2011 APPENDIX A Display Status The display of the 1756HP CELL module will provide certain diagnostics to the user as given below LED1 LED2 LED3 LED 1 This will show green if the module has booted successfully If the LED is red the module has a hardware fault LED 2 This will show green if the module has been setup successfully with the configuration image If the LED is red the module has a setup fault LED 3 This LED indicates the signal of the module Red and blinking means severely insufficient signal 0 19 Red means insufficient signal strength lt 40 Green and blinking means sufficient signal lt 60 and solid green means very good signal gt 61 NOTE If all three LEDs are red this is a fault that will inhibit the module from continuing please check the LCD for the reason and remedy as necessary LCD Below is the list of messages that can be displayed by the LCD of the module e CNFG f CNFG is displaved the Cell module has to be configured
19. vider On startup the service provider s name is requested and presented here in Ascii format and scrolled on the module s screen TextMSGPendingCount The amount of text messages that are stored on the CELL module that must be read GSM The current service level and modulation scheme that the CELL module s mobile equipment is using A Boolean bit will be active on the current service level there is a bit for each service The module will choose the best available service Note this is network dependant GSM GSM Basic cellular connection GSM GPRS General Packet Radio Services the minimum connection required for packet transmissions GSM EDGE Faster than GPRS 2 56 Signal strength given as a SINT Service provider displaved in Ascii Hiprom Technologies 6 7 2011 Amount of unread SMSs that are stored on the CELL module 0 Is not selected 1 GSM service is selected and in use 0 Is not selected 1 GPRS service is selected and in use 0 Is not selected 1 EDGE service is selected and in use 12 pri Hiprom Technologies 6 7 2011 GSM WCDMA 0 Is not selected Basic 3G connection speed 1 WCDMA service is selected and in use also known as UMTS ei kell download ti S CI e ceia iian WCDMA 1 HSDPA service is selected and in use rigo cee upload o ieee fan WCDMA 1 HSUPA service is selected and in use rente 0 Is not selected Mg Speed Upioad En 1 HSPA service is selected and in use d
Download Pdf Manuals
Related Search
Related Contents
PDFファイル - 医薬品医療機器総合機構 XN-P02-S/-K N-P01-S IW16157 User Manual 3-09 V2.indb Acide chlorhydrique Hubbell LXi-1200 User's Manual Betriebsanleitung zu 025.201: Zündverteilerprüfstand ZVP2 Taarup 7664 8_Seiter französisch.cdr INTEGRAL Science Data Centre IBIS Analysis User Manual AV Surround Sound Receiver Copyright © All rights reserved.
Failed to retrieve file