Home

AWZ 508 PK2 - Modern Alarm Kft.

image

Contents

1. AWZ 508 PK2 v1 0 RELAY MODULE EN Edition 2 dated 12 10 2010 Replaces edition 1 dated 28 10 2009 ENGLISH 1 Use PK2 AWZ 508 relay module is aimed for low voltage installations It is used for controlling and signalling conditions f ex in alarm systems and access control systems The module can be used for controlling devices characterized by high power consumption by OC alarm system outputs What is more it ensures galvanic separation of signals power sources towards module outputs It is equipped with two separate T T inputs used to trip relays with high or low condition 2 Assembly Module is equipped with plastic strip with self adhesive tape used to fasten it on a flat surface wall of the casing buffer feeder etc and holes for possible screwing the strip to the base 3 Module description 3 1 Module elements point 5 1 feeding selection jumper 2 relays 3 LED diode signals relay activity 4 module connections 3 2 Module clamps T T input of voltage controlling relay activity IN module supply input C1 C2 common relay clamp NO1 NO2 normaly open relay clamp NC1 NC2 normaly closed relay clamp 4 Technical data Number of relays i 12V 10VDC 15VDC Module power Pa DAV eva 28VDC T mA max Tripping voltage i e P T 0V 7V Relay contact voltage Max 30VDC 50VAC Relay contact power Working tem
2. f the faulty device due to reasons lying in the domain of the producer including production and material faults unless these faults have been filed within the warranty period point 1 and 2 4 Device falling under warranty period should be delivered to the point where it was purchased or directly to the seat of the producer 5 Warranty covers complete devices with written description of the fault on properly filled claim application form 6 When a claim shall be positively considered the Producer shall be obliged to realise warranty repairs in the shortest possible time however this period of time should not extend 14 working days from the date when the device was delivered to the producer s service point 7 Repair period of which mention has been made in point 5 may be prolonged in case of lack of technical possibilities to perform the repair and in case of device conditionally accepted to the service point as the claimant did not meet the warranty conditions 8 All service activities resulting from the warranty shall be performed solely within the service point of the producer 9 Warranty does not cover faults of the device resulting from reasons not lying within the power of the producer mechanical failures improper storage and transport usage not compliant with the user manual or the anticipated use of the device random events including atmospheric discharges power line failure fire flooding influence of high temperatures a
3. nd chemical agents improper installation and set up not compliant with principles included in the user manual 10 Statement of performing changes in construction or repairs performed outside the service point of the producer or when the serial numbers or warranty stickers on the device were anyhow damaged shall result in the loss of warranty rights 11 Responsibility of the producer towards the purchaser shall limit to the value of the device settled according to the determined wholesale price suggested by the producer from the date of purchase 12 Producer shall bear no responsibility for faults resulting from damaging improper activity or impossibility to use the device especially when the above results from non observance of recommendations and requirements included in the user manual or use of the device Pulsar K Bogusz Sp j Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl
4. perature 10 C 40 C Maximal switching power 6OW 100VA 80x22x43 WxHxD Dimensions Jw Weight net gross 0 05 kg 0 07 kg 5 Scheme of module connections LED diode On A B relays connected C NO contacts shorted Z1 jumper Off A B relays disconnected C NO contacts shorted Installed module feeding U 12VDC Removed module feeding U 24VDC T T gi a C1 NC1 NO2 C2 o Connections of controller B relay connections operating signals C2 NC2 shorted module is not controlled T high level C2 NO2 shorted module is controlled T low level Module feeding connections A relay connections plus minus C1 NC1 shorted module is not controlled C1 NO1 shorted module is controlled WEEE MARKING The used electric and electronic device may not be thrown out together with common household wastes According to WEEE directive binding within the EU in case of used electric and electronic devices separate means of utilization should be utilized GENERAL WARRANTY CONDITIONS 1 Pulsar K Bogusz Sp j produce provides two year quality warranty for the device counting from the date of Sale indicated on the bill of sale 2 In case when there is no bill of sale when filing the claim three year warranty period shall be counted from the date when the device was manufactured 3 Warranty shall cover free repair or provision of functional equivalent the producer shall select the equivalent o

Download Pdf Manuals

image

Related Search

Related Contents

軸ユニット 取扱説明書    PRO-LD - Bendigo Security  PDF / 136k  NetClock version 3.6.7 Release Notes  product user guide  index des titres  923-05 REV1 UM PH42 LED A - PH32 LED A [1600090].cdr  Samsung 24" S24B350TL Series 3 LED Monitor User Manual  

Copyright © All rights reserved.
Failed to retrieve file