Home

the version 2.2 User`s Manual in format. Use it for

image

Contents

1. 13 PREPARATION Fer ea nicer ceni ceto ule ne Den c ea A Cre De Dre DEL CI DTE 13 PRINTING S 14 RESULT emot nien esi 15 EBRORMESSAGES 2x tici seme s cio promis eem E ee e RUE 16 MANUAL 17 CHANGING THE GRADE Eee 17 CHANGING THE EXPOSURE TIME 0 ccccceecsseeceseecseeeceeuecseueceeueueeueeeeeneeeenes 17 ADJUSTMENTS IN SPECIAL CASES 18 BURNING IN WITH PURE YELLOW OR MAGENTA 00 c0ccseeecseesseeeseeeeeseeeeeaes 18 CONTROLLER SPECIFIC SETTINGS 19 I 19 MEASUREMENT MODE nee eene 20 GENERAL CORRECTIONS OF EXPOSURE TIME AND PAPER 21 BURN IN FUNCTION 22 ACTIVATION AND SETTING cccccccsseecsseccsceceeeeceececeueceueeeceueeuueeuuueesaneenaues 22 EXPOSING ss 23 BURN IN USING WHITE LIGHT aceeennanennnnennannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn anne 23 TEST STRIP MODES dads 24 CONTROLLING UP TO THREE DIFFERENT TYPES OF ENLARGER 26 USING THE CONTROLLER AS A HIGH QUAL ANALYSER 1 26 CARE AND
2. 28 CHANGING THEFUSE decoder ed ee eee id xia ea ee ent eri n edo 28 GOGFINSTR MENJTsi vis ek c n an neg eii e n eb eo Pn nar n a nacre dn nnns 28 APPENDIX DETAILS OF FILM AND PAPER PROGRAMS 29 FURTHER PRODUCTS OF HEILAND ELECTRONIC FOR THE AMBITIOUS PHOTOGRAPHER eene nennen nnne 31 SPLITGRADE USER MANUAL 3 Schematic view of the complete SPLITGRADE System Safelight Fillar unil inside Ihe enlarner head or madule Probe Power pug Footswitch The product Copyright All programs stored in the controller as well as this manual are protected by copyright The copyright belongs to Heiland electronic GimbH Wetzlar Germany with all rights reserved Under the copyright laws no part of the programs and no parts of this manual may be reproduced in any form without the prior written permission of Heiland electronic GmbH Wetzlar Germany Warranty This instrument carries the manufacturer s warranty for the period of two years from the date of purchase Proof of purchase is the invoice or receipt Damage caused by improper handling or unauthorised access invalidates the guarantee No warranty either expressed or implied is made of this instrument regarding its quality performance suitability or fitness for a particular purpose The manufacturer is not liable for direct indirect special incidental or consequential damages arising of the use o
3. First connect all components to the controller like filter module or filter head the enlarger lamp and the darkroom safelight Secure the signal cables by fastening the screws carefully Please do not apply brute force Then you can connect the SPLITGRADE Controller to the main voltage supply The connectors main switch and fuse are located at the rear side connector panel see Fig 2 The filters in the module will be moved to an initial position after switching ON The rotation of the motor may be audible Component Cable Plug Connector at Controller Filter module Module only for software update Jack plug 2 8mm Tab 1 Connections SPLITGRADE USER MANUAL 11 Using the controller Description of the push buttons and the display The functions are controlled by push buttons the buttons marked by have an auto repeat function One short press changes the value in one step a longer press will result in a repeated change of the value Focus ON OFF switches the enlarger light on off for setting the enlarger and scanning the picture with the probe Start Stop starts or stops the exposure time shown in the display The remaining time is still stored and can be recalled by pressing the start button again If during exposure any button other than the start button is pressed the exposure will stop and the time will be cancelled Splitgrade controllers of the first generation are using the upper symbol those of the sec
4. SPLITGRADE is an electronic instrument intended to control the contrast range of variable contrast papers VC during the enlarger process By printing the picture in two steps first through the Yellow filter and then through the Magenta filter or first through Magenta and then through Yellow the reproduction of the different tonal values is greatly improved by usage of the SPLITGRADE The contrast range of variable contrast papers will be perfectly matched to the given contrast range of the negative The characteristics of various variable contrast papers from AGFA AMALOCO FORTE ILFORD KENTMERE KODAK TETENAL and ORIENTAL are stored in the SPLITGRADE controller unit These values can be easily updated by floppy disk or download from Internet via PC if the manufacturer s paper characteristics should change The exposure time is automatically calculated for each gradation of the programmed and selected paper The exposure time and the gradation are calculated after scanning the projected picture using the probe until the darkest and the brightest areas were detected An acoustic and optical signal supports finding a quick result The evaluation and the composition of the picture takes place under white light When the filter module is disconnected the SPLITGRADE controller can be used as a high quality B amp W analyser and exposure meter The focus light will be automatically switched OFF after 5 minutes The use of the SPLITGRADE
5. 8 185 last exposure Each exposure will be started after pressing the button Time 4 39s Grad 2 0 Teststrip 20f 5 In this example the display shows the time and grade setting for the second exposure The whole exposure sequence of the test strip can be stopped by pressing any other button The time and grade in line 1 can not be altered in this menu Please note that the test strip mode Grade changes also the exposure time from strip to strip but these changes are necessary to fix the shadow value in the prints i e the reference point when changing the paper grade is the shadow value SPLITGRADE USER MANUAL 25 Controlling up to three different types of enlarger You may use different types of enlargers modules with only one controller To set up and select the module type please proceed as follows 1 Switch off the controller and connect the new filter module 2 Press and hold the button DJ while switching on Hold the button until the following display appears In the first line the Module s original delivered module is displayed 1 LEITZ V35 e g Leitz V35 2 None 3 None 3 Move the cursor to one of the three lines by using xj buttons and select the module type with the buttons ATTENTION The enlargers AGFA Varioscope Leitz Ic and llc use all Dunco Filtermodules so please select DUNCO in this case 4 By pressing the button you may toggle between the described menu and a
6. different test strip modes for various purposes One test strip mode alters the paper grade In the other modes you may alter the time and use separate exposures which is recommended or additive exposure times Within every test strip mode you have the flexibility of setting the total number of test strips as well as the step size Test strips are generated with the main exposure centred within an odd number of strips Before you start the test strip mode it is recommendable to measure the negative first securing a good centre point For special applications you may also enter the main exposure time and grade manually in menu 1 main menu Then enter the test strip menu by pressing multiple times the button until you get a display similar to the following example Main exposure time and grade Time gA Ged 20 Test strip mode e g time separate Teststrip Time Sep Count 5 Total no of test strips Step width 0 3f Width or size of change from step to step As in any other menu you can move the cursor by using the or button and alter the value that is indicated by cursor with the or button After you have defined all necessary values press the button to start the exposure for the test strips The display will show the actual time and grade while exposing 24 In this example five strips are generated with a paper grade of 2 0 and the following times first exposure 3 56s 4 395 5 405 6 655
7. setting for the exposure will be adjusted automatically according to these changes Note All offsets are stored even when the SPLITGRADE Controller is switched off For every paper a separate Offset can be chosen Resetting the values to factory calibration is done by selecting 0 0 SPLITGRADE USER MANUAL 21 By using these corrections you can easily adapt the exposure time and the grade setting to the specific properties of your darkroom or the requirements of your image By pressing the button several times you return to the main menu BURN IN FUNCTION Activation and Setting Your SPLITGRADE has a very useful burn in function It enables you to store up to 7 independent burn in times building up an exposure sequence together with the main exposure time The main exposure is automatically followed by the burn in exposure To enter the menu with the burn in functions press the key several times If the controller is in the main menu a short cut is to press the two keys and gt simultaneous Grade of main exposu e g grade 2 0 Grade of 1 BI e g 5 Grade of 2 BI e g 0 Grade of 3 BI e g burn in with white light Main exposure e g 5 4s 1 burn in e g 3 16s 2 BI e g 0 7 f stops of main exposure i e 0 7f of 5 45 3 375 0 7 3 BI e g 2 05s In line 1 TO the calculated main exposure time and grade are listed If you change these values please pay attention to the fact that the time and grad
8. 00s Go back to time TO by using button To start the exposure sequence press the button After the main exposure is finished the cursor moves on to line 2 and the first burn in time can be started by pressing again The whole sequence is terminated after the last programmed maximum 7 exposure has been executed and the cursor moves back to time TO You may stop and continue an exposure by pressing the again or you can terminate the whole sequence at any time also while exposing by pressing any other button Between the single steps of the sequence you may turn in the red safe light filter in front of the lens and switch on the focus light in order to search for areas that should be dodged The focus mode will not terminate the exposure burn in sequence All settings will be stored automatically when you leave the burn in menu Of course you may also select only one of the burn in times and start this time by pressing the button To quit the burn in function press the key the main menu is displayed Burn in using white light For any of the burn in times 1 7 you may select white light for burn in To do so change the paper grade to 5 0 and press one more time or select paper grade 00 0 and press The display will then show to indicate the while light mode To cancel this setting simply select another paper grade SPLITGRADE USER MANUAL 23 TEST STRIP MODES The SPLITGRADE system incorporates 3
9. Heiland electronic GmbH SPLITGRADE Paper Gradation Management System User manual V2 2 Contents SCHEMATIC VIEW OF THE COMPLETE SPLITGRADE SYSTEM 4 THE 5 GORY RIGHT W 5 WARRANTY b ER 5 TECHNICAL SPECIFICATIONS OF THE CONTROL UNIT eene 6 FACTORY CALIBRATED PAPER 7 8 CONTENTS OF THE DELIVERY 8 FEATURES ach cA tro EA SLE CM 9 OPERATION 10 ALL EE EM REDE RERUM 10 INSTALLING THE FILTER MODULE AND CONTROLLER 10 CONNECTING THE SYSTEM ipi Ioue y eoe E cde vu See eov e Duns 11 USING THE 12 DESCRIPTION OF THE PUSH BUTTONS AND THE 12 BIST NAME 12 THE PATH TO HIGH QUALITY PRINTS
10. IGRADE P IL MGIVRC F Conv IV RC film used here Conventional silver Film e f you are using a different paper move the cursor to the 2nd line to P by pressing the amp or 5 button Start the selection of the paper type by pressing the or button Each time you press the button a sub menu will appear listing the manufacturer of the paper in line one and in the subsequent line SPLITGRADE USER MANUAL 13 their various papers Continue pressing the or button until your preferred paper is displayed Quit the selection by pressing the button e f necessary move the displayed cursor to in the display and change the type of film in the same way Printing e the negative in the negative carrier e Switch the enlarger light ON by pressing the J button set up the enlargement size and compose the image which is done under white light The following display appears deu Hint on the measurement Mode continuous mode see page 20 Start density meas Previous contr 0 00 The measured contrast of the previous negative Focus the negative and stop down the f stop of the enlarger lens Measurement is always done at working f stop e Putthe probe on any part of the projected image taking care that the window on top of the measuring cell is uncovered Start the measuring procedure by briefly pressing the red button on the probe An intermittent signal sounds and yo
11. apers Factory setting is made for low normal and high sensitive paper Calibration is done with general corrections see page 21 Exposure with white light time and grade are to be defined by the user SPLITGRADE USER MANUAL 7 Please note All factory settings assume fresh chemistry and paper and 20 Celsius bath temperature Factory calibrated film types Film type Display Conventional Silver halide film Conv ILFORD 2 XP2 ILFORD XP2 Super XP2S KODAK 400 T400C KODAK Portra Portr KONICA VX400 VX400 Notice When a chromogenic B amp W film is selected an additional symbol will be displayed for the film speed selected during the exposure for 50 100 ASA for 200 400 ASA for 800 1000 ASA Contents of the delivery If any of the following items are missing or damaged please contact your supplier immediately e The enlarger module or enlarger head with the motor driven filter wheel e The controller which interprets the measured values translates them into the appropriate paper grade and exposure time and controls the filter wheel The probe which scans the projected picture and transmits the values to the controller e The footswitch starts or stops the exposure The cables to connect the controller enlarger and darkroom safe light Note we recommend to keep the packaging of the instrument in case of the need for a return shipment Features
12. diately after switching the button press either or button The following display will be Focus active shown Mode Multipoint Start dens measure Previous contr 0 89 To measure the density of the selected points place the Probe in the relevant area and press the red button of the Probe for a short moment You e s 20 may also move the Probe over the desired area while pressing down the red button To calculate grade and time release the red button and press again General corrections of exposure time and paper grade Press the button until you get the following display Offset Time 0 0 f Offset Grad 0 0 Exposure time If due to changes in the paper emulsion your darkroom conditions the kind of images or your perception of your prints are generally looking too bright or too dark you may compensate this by adapting the exposure time Press the 1 or gt button until the cursor is at position Offset Time Press the or the button you can change the exposure time in 1 10 f stops For special applications like Lith printing the range of exposure time offset is 4 f stops The setting for the grade is not affected by these changes Paper grade If your prints are generally too hard or too soft you should change the grade setting Press the for the button until the cursor is at position Offset Grad Using the orthe button you can change the setting in 0 1 steps The
13. e in menu 1 are also altered accordingly Changing the time grade in either line is done by pressing the J or gt button until the cursor appears in the desired position The display switches automatically between Times 0 to 3 and 4 to 7 while moving the cursor Altering the values of the time and grade is done by pressing or E By pressing these both keys simultaneous you alter the mode of the burn in time which is actually marked by the cursor You decide if the time should be independent of the main exposure in the above example T1 and T3 or should be adapted to the main exposure in case that the main exposure is altered in the above example T2 This feature could be selected for any of the burn in times The advantage of the f stop method is that after a change of the enlargement scale you only have to measure the main exposure time again and the whole burn in sequence is adapted to this new time 22 If you have entered all the times and grades for a special sequence set the cursor to the first unused burn in exposure time Press and hold the button in order to change this time to 0 00s or 0 0f stop This signals the end of defining the exposure sequence to the controller Exposing Example You may like to use the main exposure and two additional burn in times as well The values TO and GO are the main exposure values T1 G1 are the first burn in and T2 G2 are the second burn in time Afterwards please set T3 to 0
14. igrade 1 9 60 5 ILFORD Multigrade RC Cooltone IL MGRCCT ILFORD Multigrade 1 9 60 s ILFORD Multigrade IV FB IL MGIVFB ILFORD Multigrade 1 9 120 s ILFORD Multigrade FB Warmtone IL MGFBWT ILFORD Multigrade 1 9 120 5 KENTMERE VC Select KE SERC KE VC Select Plus 1 9 90s KENTMERE Fineprint VC FP FB KE VC Select Plus 1 9 100 5 KODAK Polymax II RC KO PMIIRC KODAK Polymax 1 9 605 KODAK Polycontrast III RC KO Dektol 1 2 60 5 KODAK Polymax Fine Art FD PMFAFD KODAK Dektol 1 2 150 5 MACO Multispeed 1Fneu und 2M use setting Multicontrast Sepia VC RC SP RC MOERSCH2Warm 1 9 1205 MOERSCH Sepia VC FB SP FB MOERSCH 6 Blue 1 9 180s ORIENTAL New Seagull FB ORSEFB AGFA Multicontrast 1 6 150s ORIENTAL New Seagull Select VC RP use setting Kentmere VC Select TETENAL Vario Ultra RC TT VURC TETENAL Variospeed 1 9 60s TETENAL Vario Comfort RC TT VC TETENAL Variospeed 1 9 60s TETENAL Vario Fineart FB TETENAL Variospeed 1 9 90 5 TETENAL Baryt Vario FB TETENAL Variospeed 1 9 90s TETENAL Work use setting AGFA MCP RC ZONE VI Brilliant VC III ZVI VOII ILFORD Multigrade 1 9 120 s Other papers Others Paper of fixed gradation Fixed These papers have not been calibrated but the mentioned settings may be used with good results That does not mean that papers are identical These 3 channels may be used to adapt other p
15. ils When you change to a softer grade you will always get white and black but the print might loose brilliance These changes are valid until a new measurement is started Changing the exposure time If after developing the print you have the impression that the exposure time of the print should be a little longer or shorter move the cursor in the display to line 1 position Time and change the exposure time with the orthe button in steps of 1 10 f stops or in units of seconds in the direction you wish Theses changes are valid until a new measurement is started SPLITGRADE USER MANUAL 17 Adjustments in special cases Portraits If there is a lack of black and white tones in the negative you should first change the measured grade to a softer grade The amount of change necessary can only be estimated If necessary you should also change the exposure time The most important part to evaluate the correctness of the exposure is the highlight skin tone White egg on white plate In this case the contrast is very low and the measuring device is compensating for this with a too hard grade and a too long exposure time Solve this problem by altering these values in the opposite direction Black dog on black coal In this case the contrast is also very low Like in the previous example a softer grade has to be selected but the exposure time should be extended Same tone range for different enlargement scales If you like to get
16. ith the setting If you are not able to get satisfactory results try to use the General corrections see page 21 Paper programs The papers listed in the Table 1 are all with glossy surface and were developed in a tray strictly following the recommendations of the manufacturers including the kind of chemicals used and developing time The prints were dried with hot air at 60 If you prefer to use papers with a matt surface it could be necessary to adjust the programs accordingly Note The use of old materials paper or developer or varying the instructions of the manufacturers may change the results you can expect 30 Further products of Heiland electronic for the ambitious photographer Systems for effective testing of films and papers High precision mono chrome densitometer for all tasks in general B amp W photography microfilm applications and repro companies Color densitometer for C41 process control If you would like to receive more information about our products please refer to our address located on the back cover SPLITGRADE USER MANUAL 31 Heiland electronic GmbH Schulstrasse 8 D 35579 Wetzlar Phone 49 6441 26978 Heiland electronic Fax 4449 6441 26988 Wetzlar email heielec t online de Internet http www heilandelectronic de
17. lay and push button illumination is switched off e g when working with films or colour papers in the darkroom Beeper Metronome Every second a short signal is produced while the exposure time is elapsing Filterchange 1 sec before the filter changes a long signal is produced Off No signal during the exposure time SPLITGRADE USER MANUAL 19 Time base Toggles the time base between 1 10 f stops and units of one second The advantage of 1 10 f stop is that changes are easier to evaluate when you are thinking in density values Moreover changes are faster when the exposure time is long Changing the time in units of a second adapts the step size dynamic to the exposure time and uses step sizes of 0 01 0 1 1 seconds depending on the absolute exposure time A quick change of exposure time is possible by pressing and holding the or button This mode is provided for photographers who do not like to work with 1 10 f stops Filter To change the sequence of filtration This is very helpful when you want to burn in or dodge the print To change for example some areas in the picture during the exposure with Yellow light it is advisable to choose the sequence Magenta Yellow You thus can locate the area during the Magenta exposure phase in order to manipulate this area immediately after the filter change Measurement mode A second mode may be implemented for measuring only selected parts of the negative To activate this mode imme
18. ll be damaged Make sure that the mains voltage and frequency are in the range indicated on the identification label on the bottom of the instrument This instrument should only be connected to a properly installed voltage supply outlet that has been properly grounded to earth It is not permitted to exchange the power cables for any other without protected ground earth wire and safety plug Always keep the instrument in a dry place and never immerse it in any kind of liquid To prevent electric shock do not open There are no user serviceable parts inside To avoid fire hazard use only a fuse of the correct type voltage and current rating as specified in technical data see page 6 Installing the filter module and controller All filter modules or enlarger heads supplied together with SPLITGRADE are compatible to those of the enlarger manufacturer Please refer to the user manual of the enlarger regarding the installation of the module or head Do not install the set in a hot or humid place or in a place subject to excessive dust Take care that there is enough working space around the controller to operate it safely in the dark Connecting the system The controller can be used at any voltage between 90V and 250V 50Hz and 60Hz It will adapt automatically to any value within these ranges Com 7 Module On Off Erlarger Safelight Power Supply Fig 2 Rear view of the SPLITGRADE Controller unit
19. menu that enables to enter filter offset values for yellow green and magenta blue filters If you have so far used values in or you do not know the offset values please contact Heiland electronic to receive the values in units of 1 10 f stop Further more you are able to enter a delay time which is defined from switching on the enlarger output until the shutter is opened You may change this time if you use a stabilised transformer which need more then 0 5 sec until the lamp is switched on Please note all settings on a sheet of paper 5 Finally select the required enlarger or module type by moving the cursor in the corresponding line and press the button In case of a module error or in case of a non existing module the controller displays Module Error In this case check the module and switch on again or quit the error Module type message and use the controller as a Bres kev ICONS timer only y 26 Using the controller as a high quality analyser SPL M1 The controller of the SPLITGRADE system can used as a B amp W analyser and timer in conjunction with enlargers for which there is at present no motorised filter module The version with order code SPL M1 is already set to this manual split exposure mode Prior to working the controller need to be calibrated in reference to your enlarger An instruction for calibration may be requested at the manufacturer in this case please mention the type of enlarger a
20. module enables the production of high quality prints and fine art prints at highest level never reached before and not equalled by any other system The SPLITGRADE module is not only the translation of our sensitometric knowledge but also the comprehension of our practical experience acquired over many years As this printing system greatly improves printing efficiency while saving time chemistry and paper every photographer will have much more time for creative printing SPLITGRADE USER MANUAL 9 Operation conditions Safety advice This instruction manual should be read prior to installation and first use The SPLITGRADE controller and module contained in this package are intended to operate only with the appropriate enlarger The type of enlarger is specified on the front label of the package To prevent electric shock or fire hazard remove the power cord from the AC supply prior to connecting or disconnecting any signal lead or prior to replacing the fuse If one of the AC cables becomes damaged replace it immediately or refer servicing only to qualified personnel Should any liquid fall into the SPLITGRADE controller or modules unplug the set and have it checked by qualified personnel before operating it any further Unplug the SPLITGRADE controller from the voltage supply if it is not going to be used for several days or more To disconnect the supply cable pull it by the plug Never pull the cord itself otherwise the cable wi
21. nd light source To use the manual split exposure proceed as follows e Install and set up the controller according to the description on page 10 e f you have not purchased the SPL M1 version follow the instruction on page 26 to set the enlarger type to Manual e Select paper and film type e f using a colour or multigrade head on the enlarger set to white light Otherwise remove all filters from the light path e Switch the enlarger light ON by pressing the CJ button e Select the f stop in order to achieve a exposure time of at least 5s This will reduce the effect of lamp start up and after glow on the exposure e Measure the exposure and grade as described on page 14 e Terminate the measurement by pressing the button again Press the button and select the displayed filter type On the colour or multigrade head dial maximum magenta or yellow otherwise insert grade 5 or grade 00 filter in the light path e Start the first exposure by pressing the button m e Remove the inserted filter or select filter position 0 and select the second filter as displayed in the controller display Start the second exposure by pressing the button again e The image has been exposed by using two different filter settings according to the split grade method SPLITGRADE USER MANUAL 27 CARE AND MAINTENANCE CAUTION To prevent electric shock do not open the instrument There are no user serviceable parts inside Note Any unau
22. ng of the contrast in 0 1 steps with automatic density control in1 10f stops or 0 1 sec steps with constant grade factory adjusted for 29 papers main brands AGFA AMALOCO FORTE ILFORD KODAK KENTMERE MOERSCH ORIENTAL TETENAL and 6 films updates by floppy disk or internet download via PC reading probe foot switch RS232 illuminated LCD display with 4 lines 90 to 250 V 45 to 65 Hz automatic setting 160mm x 260mm x 80mm approx 1kg without accessories and crating controller filter module probe footswitch electrical connectors 6 3A time lag Factory calibrated paper types Paper type Display Developer Dilution Time AGFA Multicontrast Premium RC AG MCPRC AGFA Neutol 1 7 60s AGFA Multicontrast Classic FB AG AGFA Multicontrast 1 6 1205s AMALOCO Varioprof Extra RC AM VP RC AM Varimax 6006 1 9 90 5 BERGGER Prestige Variable ILFORD Multigrade 1 9 120 s BERGGER Prestige Variable BEPRNB ILFORD Multigrade 1 9 120 s FORTE Polygrade V RC FO RC ILFORD Multigrade 1 9 70s FORTE Polywarmtone RC FO PWT RC ILFORD Multigrade 1 9 70s FORTE Polygrade V FB FO FB ILFORD Multigrade 1 9 120 s FORTE Polywarmtone Plus FB FO PWT FB FORTESPEED NTD 1 9 120s FOTO IMP Classic Art FB PW matt IM Tetenal Eukobrom 1 9 180s FOTO IMP Polycooltone FB use setting Bergger NB ILFORD Multigrade IV RC IL MGIVRC ILFORD Multigrade 1 9 60s ILFORD Multigrade RC Warmtone IL MGRCWT ILFORD Mult
23. ond generation the second symbol Plus increases the value marked by the cursor in one step or changes the function Minus reduces the value marked by the cursor in one step or changes the function Cursor moves the cursor in the direction of the arrow or to the next line Page switches between the pages of the LCD display EJ A UJ 9 Foot switch starts or stop the exposure Probe switch starts and stops the density measurement Display All data important for the working of the system are shown in the 4 lines display The brightness can be regulated by turning the resistor using a screw driver cautiously The resistor is accessible through a tiny hole at the left side of the controller 12 THE PATH TO HIGH QUALITY PRINTS In order to profit from the SPLITGRADE system very quickly you should proceed as follows Preparation e Connect the controller following the safety advice on page 10 Use a paper and matching chemistry as indicated on page 7 of this manual using only fresh paper and chemistry Do not use old paper or used chemistry Switch the controller ON If the filter module and the probe are connected properly the controller displays the following information for a short while 1 Software version 2 Type of enlarger This display will then look like the following one Exposure time in sec Paper grade from 0 00 to 5 0 Time 5 40 s Grad 2 0 Cursor Paper used here ILFORD MULT
24. r inability to use this instrument or documentation even if advised of the possibility of such damages In particular the manufacturer assumes no liability for any material including negatives or photographs used with this instrument including whatever costs of repairing replacing or recovering such materials This instrument has been carefully manufactured and tested using flawless materials and state of the art technology In case of failure return the instrument to an authorised service agent accompanied by proof of purchase Within the warranty period the manufacturer assumes the cost of replacement parts and repair The manufacturer reserves the right to replace the instrument in lieu of repairing at its discretion Valid for software rev 2 2 March 1st 2004 Changes without notice SPLITGRADE USER MANUAL 5 Technical Specifications of the control unit Measuring probe Exposure control Measuring range Exposure time range Resolution Time error Gradation input Manual input gradation time Grad tables Interfaces Display Voltage supply Dimensions WxLxH Weight Delivery content Fuse probe for exposure and gradation reading automatic setting of filter module and operating panel acoustic support by beeper and LED diameter of reading point o3mm built in exposure timer and light shutter 0 01 10 Ix 10 f stops 0 5 500 sec 0 01 sec 0 596 repeatability error 0 196 automatic in 0 1 steps after readi
25. r various chromogenic B amp W films developed in a professional lab under typical conditions for the particular film Detailed tests show that despite the strictly standardised developing process C41 the tint of the film can differ from laboratory to laboratory As these differences can imply non predictable differences in exposure time and grade the measured values can only be a clue which should be adjusted if necessary Another peculiarity of chromogenic film is its reaction to different exposures In the same way as for silver halide films the best results are obtained when the exposure is done with enough light The reduction of the ASA setting by about a half or a quarter improves the details in the shadow areas of the print and yields finer grain The contrast of the negative changes with the exposure value with increasing exposure the contrast becomes higher with the result that doubling or quadrupling the ASA value yields negatives which are hard to print For all these reasons the programs for chromogenic films are provided with a compensation for the different modes in which the film was exposed They are collected in the group N for normally exposed film for longer and for shorter exposures SPLITGRADE USER MANUAL 29 When you do not know the exposure mode for a given film start with the adjustment N If the result is too light try again with the setting if they are too dark try it w
26. se refer to the chapter Manual change of the grade on the next page SPLITGRADE USER MANUAL 15 Error messages Failures during or after measuring will be announced by a signal and displayed as follows Too much light Too much light close the f stop Start meas again and start measuring again Too little light Too little light open the f stop and Start meas again start measuring again Exposure time is too long open the f stop and Time too long start measuring again Start meas again Exposure time is too short close the f stop and Time too short start measuring again Start meas again The measured contrast is out of the print range of the selected paper If you proceed you may loose details in highlights or such will become too grey because the paper grade could not be fitted to this negative Check contrast MANUAL CHANGES Changing the grade If after developing the print you have the impression that the grade of the print should be a little harder or softer move the cursor in the display to line 1 position Grad and change the grade with the or the button in steps of 1 10 grade in the direction you wish When you change the grade the exposure time will automatically be adjusted By making the print harder you always will get the deepest black but you might lose details in the highlights If you try to compensate for this by choosing a longer exposure time the shadows will also lose deta
27. the same tonal range for pictures of different magnification you should always select the same points to measure the grade and the exposure time If the darkest and the brightest points are not situated in the area to be printed do not hesitate to look for these points outside the printing area Burning in with pure Yellow or Magenta If the cursor is in line 1 Pos Grad then you may fast change the paper grade to 00 0 by pressing the and 4 simultaneously or to 5 0 by pressing and simultaneously Depending on the selected paper the light for grade 00 0 may contain a small amount of Magenta This is not an error it is needed for reaching the max density of the paper USER PREFERENCES Controller specific settings Changing the factory set values Change the settings of the controller according to your needs Every change will be stored even after switching OFF the power until you change these values again Press the button to get the following display i or gt moves the cursor to a different line or changes the setting Toggle the Displaylight ON or OFF Changes the beeper mode to Metro nome Filterchange or Off Displaylight _ On Beeper Filterchange Timebase 1 10f Changes the time base from 1 10 f Filter Yellow Magenta stops to units of one second Changes the filter sequence from Yellow Magenta to Magenta Yellow Details of the functions Displaylight On Normal setting Off Disp
28. thorised opening or servicing invalidates the guarantee Changing the fuse The fuse is located in a fuse carrier in the power entry module on the rear side of the instrument To change the fuse remove the power supply cord and open the fuse carrier by using a small screwdriver Use only fuses with the same values listed in the technical data Care of instrument The case should be cleaned with a lightly dampened soft cloth or chamois only if necessary with the addition of a mild cleaner Do not use solvents or abrasive materials The probe should be cleaned only with a soft brush or compressed air to remove dust otherwise the incorporated sensor might be damaged permanently Unplug the instrument when not in use for long periods of time For necessary repairs send the instrument to the manufacturer or authorised service centre 28 APPENDIX DETAILS OF FILM AND PAPER PROGRAMS The controller is factory equipped with programs controlling the exposure time and grade for a given combination of variable contrast paper and negatives of a certain kind These programs may be adjusted from time to time according to the current characteristics of commercially available papers and films Program adjustment for films The program Conv covers all conventional silver halide films as long as the film base does not show any peculiar colour which could influence the measurement of the time and the grade The other programs cove
29. u will have the following display Focus active Mode continuous Density meas active Contrast 0 00 e Move probe over the projected image looking for the darkest and the brightest areas until the signal stops Maximum probe movement velocity is 14 We recommend not to measure very small spots like lamps and candle lights in our experience their contribution is not important for the overall impression of the print but can falsify the measurement resulting in too soft a grade e _ Stop the measuring procedure by pressing the red button again You will get the following display Result of the measurement Focus active i e 1 05 Mode continuous Density meas active Contrast 1 05 Switch OFF the enlarger light by pressing the E button The display shows the exposure time and the gradation as calculated by the controller for the selected paper and film type If there is any error report the measurement should be repeated Put the paper on the enlarging easel and start the exposure by pressing the button e Develop the paper according to the procedure described by the manufacturer Result The lightest and darkest portions of the negative which have been measured result in near max density and near white print tones This technically correct print which includes the whole tonal value scale of the paper will satisfy your requirements in most cases If you wish to change the print plea