Home

Portable Evaporative Air Cooler User Manual

image

Contents

1. Honeywell Portable Evaporative Air Cooler User Manual Read and save these instructions before use Scan Here www honeywellaircoolers com products CO301PC www honeywellaircoolers com Model CO301PC E mail info honeywellaircoolers com 1 Touch Screen Control Panel 7 Water Inlet Valve 13 Power Cord Wrap 2 Louvers 8 Water Level Indicator 14 Overflow Hole 3 Front Grill 9 Beverage Can Holders 15 Drain Plug 4 Front Honeycomb Cooling Pad a Top Storage Compartment 16 Power Cord amp Plug 5 Casters 11 Rear Grill 6 Water Fill Door 12 Rear Honeycomb Cooling Pad WARNING READ AND SAVE THE AIR COOLER SAFETY amp MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND OR IMPAIR ITS OPERATION AND VOID THE WARRANTY TOUCH SCREEN CONTROL PANEL 48 va ul amp NOTE The Control Panel uses soft touch control Operate the air cooler by touching the buttons of the Touch Screen Control Panel FUNCTION BUTTONS POWER Touch the button to turn the unit on The cooler will start automatically at medium speed After a few seconds the speed will switch to low To turn the unit off press the power button for 2 seconds or longer timer HDH Touch the TIMER button until the desired time duration setting is selected When the set time has passed the unit will automatically turn off unit remains in Standby mode until power cord is unplugged from el
2. ch OFF the unit and unplug from he power outlet Fill the water tank with water above the minimum water level mark Plug in and switch ON again To deactivate the alarm and continue using the unit as a fan without evaporative cooling switch the unit OFF and then ON again The Low Water Alarm will not activate in Fan only mode The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty CLEANING amp DRAINING THE WATER TANK Below are instructions on how to clean and maintain your air cooler If the cooler will not be used for a long period of time please refer to the STORAGE amp MAINTENANCE GUIDELINES located in the separate Safety amp Maintenance Guide WARNING Before cleaning the unit switch the unit OFF and disconnect from the power outlet Move the unit to a location where the water can be drained Remove the cap from the Drain plug located at the bottom of the unit Allow the tank to empty Refill the water tank with clean water and drain it completely Clean the water tank with dish detergent or a damp cloth and rinse it thoroughly Refill the water tank with clean water up to the maximum level Use a damp cloth to remove the dirt and dust from the surface of the unit Never use corrosive elements or chemicals to clean this product When the product is not in use store the unit in a dry place our of direct sunlight CLEANING THE HONEYCOMB COOLING MEDIA e The appliance i
3. crews from the Front Grill of the Air Cooler 2 Carefully pull out the Front Grill from the Air Cooler 3 The Honeycomb Cooling Pad is secured on the Honeycomb Frame that is fixed in place by screws on the Left and Right Side of the Honeycomb Frame Remove these screws to release the Honeycomb Frame Cover 4 Pull out the Honeycomb Frame Cover and Honeycomb Cooling Pad Replace with the new Honeycomb Cooling Pad by put into the grooves of the Honeycomb Frame until it fits comfortably and securely in place on the frame Replace the Honeycomb Frame Cover rear back onto the Honeycomb Frame by replacing the screws and tightening them in place This secures the Honeycomb Cooling Pad in place on the Honeycomb Frame 5 Repeat steps 1 to 4 to remove the Honeycomb Cooling Pad on the Rear Grill WARNING DO NOT operate the Air Cooler when the Front or Rear Grills are removed from the Air Cooler or if there is a loose fitting Front or Rear Grill Doing so can cause serious injury or dangerous electrical shock TECHNICAL SPECIFICATIONS Model C0301PC Voltage 220 240V Frequency 50Hz Wattage 270W Water Tank Capacity 30 Litres 7 9 Gallons Cooling Media Honeycomb 433 W x 570 D x 1131 H mm GEIER 17 0 W x 22 4 D x 44 5 H in Net Weight 24 kg 52 9 Ibs ELECTRICAL WIRING DIAGRAM Version 220 240V 50Hz COOL SWING Capacitor ed Black H L COOL FIR oO L Hara
4. e remote control and insert batteries inside Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment e Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path is not obstructed e Remove the batteries if the unit is not going to be used for an extended period of time Do not drop the remote control e Do not mix different types of batteries such as alkaline carbon zinc or rechargeable batteries e Do not mix old and new batteries e Exhausted batteries are to be removed from the product COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product Please refer to the COOLER LOCATION section of the separate Safety amp Maintenance Guide FILLING WITH WATER CAUTION Unplug the unit from the electrical power outlet before emptying or refilling the water tank Continuous Water Supply Connection For a continuous water supply you will need a garden hose that is connected to a mains water supply Water inlet valve e Locate the male connector at one end of the garden hose Insert the garden hose connector into the water inlet valve of the cooler Screw and tighten the water inlet valve onto the threaded part of the garden mae hose connector making sure the hose connector is secured to ensure there will be no leaks If there is a leakage the
5. ectrical socket The TIMER function allows you to program the unit for up to 8 hours of use swing RA Touch the SWING button until the SWING indicator light is illuminated on the control panel The louvers will begin to move left to right automatically Vertical Air Flow You can manually adjust the louvers to change vertical air flow speen ul Touch the SPEED button repeatedly to change the speed between High and Low The display will show he selected speed FUNCTION BUTTONS CONTINUED coo Sr Touch the COOL button until it is illuminated on the display screen This activates evaporative cooling The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet When COOL is not illuminated the unit switches to a fan only mode without evaporative cooling sarety Lock 3 To avoid accidentally touching and changing the set air cooler settings you can touch both the POWER COOL buttons at the same time to lock the control panel Touch both POWER COOL at the same time again to unlock the control panel buttons REMOTE CONTROL OU Power ON OFF ull Speed Low High Sr Cool Controls cooling or fan option 2 Swing Controls the motion of the louvers Timer Controls the Timer function for automatic shut off Note e The remote control requires two new AAA dry cell batteries for replacement e Open the battery compartment at the back of th
6. hose and the water inlet valve may not be connected properly Try to disconnect replace and tighten the water inlet valve again avon Hose FILLING WITH WATER CONTINUED e When the connection is secured turn ON the water supply and the water will flow into the water tank of the cooler e The cooler is now set so the water refills automatically when the water tank is empty or when the water reaches below a minimum level e When the water tank is full of water the water inlet valve will automatically stop the water supply from overflowing the water tank WARNING The maximum water inlet pressure is 0 5 MPa Manual Water Tank Refill Open the Water Fill Door located on the side of the unit The Water Level Indicator is located at the side of the unit Refill the water ank when water level is low Do not fill water above the Max water level mark Check the water level in the tank before running the COOL unction Make sure that the water in the tank is above the minimum ged SE water level mark Running the unit in COOL mode with inadequate water Wiebe ater Fill Door may cause pump failure LOW WATER ALARM The unit is equipped with a low water sensor In Cooling Mode when water in the tank is below the minimum level you will hear a beeping sound and the ZS will flash continuously The unit will automatically pause evaporative cooling Refill the water tank to deactivate the alarm in cooling mode First swit
7. m PCB1 wie N oA Float sensor switch PCB2 LZ For Low Water Alarm Distributor KHIND ALLIANCES SDN BHD 811092 W No 2 Jalan Astaka U8 82 Bukit Jelutong 40150 Shah Alam Selangor Malaysia Service Center 1 800 88 0032 Email kas inquiry khind com Website http www khindalliances com AirTek International Corporation Limited JMATEK International Group of Companies Manulife Financial Centre Kwun Tong Hong Kong Phone 852 2559 5522 Email info honeywellaircoolers com Web www honeywellaircoolers com Made in China 2015 AirTek Int l Corp Ltd All rights reserved The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representations or warranties with respect to this product This product is manufactured by Airtek Int l Corp Ltd Honeywell
8. s supplied with two Honeycomb Cooling Media pads e The Honeycomb Cooling Media are located inside the Front amp Rear Grills See Step 1 to Step 5 for instructions on how to remove them from the unit for cleaning and maintenance e Do not run the unit in COOL mode with stale water in the tank You must empty the water tank and refill with fresh water especially if the tank has not been cleaned in a long time e The cleaning frequency for the Honeycomb media depends on local air and water conditions In areas where the mineral content of water is high mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits If mineral deposits remain on the Honeycomb Cooling Media the media should be removed and washed under fresh water The media should be cleaned every two months or sooner depending on your needs e For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off Step 1 Step 2 Taisen Front Fron y U Rear crt Rear Grill LS Step 3 Step 4 Be EE a TERI en Roar Pai CR SE DAIN pane CH Honea BH a DE Step 5 Step 6 Honeycomb Honeycomb Pad Frame Cover P Removing the Honeycomb Cooling Media 1 Remove the s

Download Pdf Manuals

image

Related Search

Related Contents

EnGenius ESR-9710 WLAN access point  82 motec 0.55 - 2.2 kW de-en-fr  024 Caractéristiquestechniques 104 Outillage  Yamaha 2013 Road Star Silverado S Owner's Manual    フィンガープローブ TL-101S フィンガープローブ TL-101T  取扱説明書(日野編)最新版のダウンロードはこちら - G-scan  RAVE Water Sports Equipment User Manual  

Copyright © All rights reserved.