1. 2553A 2553 Range 10 mV 100 mV 1 V 10 V 30 V 10 mV 100 mV 1 V 10 V DC Voltage Accuracy 1 V range 75 ppm 1 year 300 ppm 1 year eee lt 10 moO lt 1 50 ECEN Range 1 mA 10 mA 30 mA MAX 30 V output 100 mA 1 mA 10 mA 100 mA Accuracy 1 mA range 120 ppm 1 year 400 ppm 1 year Thermocouple type R S B J T E K N C A User defined R J T E K Temperature RTD Pt100 User defined Unsupported Resistance generation 400 Q range Unsupported Main setting digits 5 5 4 5 Number of dials 5 3 Dimensions 213 W x 132 H x 300 D mm 228 W x 149 H x 365 D mm Weight Approx 3 kg Approx 8 kg Communication USB TMC Ethernet GP IB option Interface GP IB also 2553 compatible mode Improved items are written in bold Programs may need some modifications Application Application Calibrating and testing analog meters The 2553A can calibrate and test analog meters up to 32 V voltage and 120 mA current The strong click from the dial enables easy adjustment of output value without actually looking at the front panel of 2553A Calibrating and testing temperature controllers The 2553A can calibrate and test temperature controllers and data loggers using thermocouple and RTD It provides 10 types thermocouple regulated in IEC By setting temperature value it generates thermocouple electromotive power and calibrates temperature controllers It covers various temperature controllers s
2. ilV ava ag AAA AAAA a Ai Variation ppm 0 10 20 30 40 50 60 Elapsed time Minutes High stability As reference data GAWA 2553A PRECISION DC CALIBRATOR 1 Main set value 4 Output ON OFF switch 2a Temperature type selection Output terminals E Voltage current range selection Intuitive operation Dials and switches are provided for each digit and function Traditional 7 segment LEDs provide clear visibility Various temperature calibrations The 2553A provides well used K T E J and additional 6 types of thermocouples These 10 types are all regulated in IEC It also provides widely used Pt100 as an RTD Resistance as well as temperature value can be set as an output value enabling instrument calibration by both values Use existing 2553 programs The 2553A communication command is backwardly compatible with previous 2553 model By using 2553 command mode it is possible to replace 2553 to 2553A without modifying your programs It is also possible to mix 2553As and 2553s in the same system Programs may need some modifications YOKOGAWA TC type Source Range C R 50 to 1768 S 50 to 1768 B O to 1820 J 210 to 1200 T 270 to 400 E 270 to 1000 K 270 to 1300 N 270 to 1300 C 0 to 2315 A 0 to 2500 RTD Source Range C Pt100 200 to 850 Resistance output Source Range Q 400 18 to 400 Comparison with previous model 2553
3. Connected to the 758933 or 758917 Used in combination with the 758921 or 758922 Rating 1000 V CAT II 82 A 758921 Fork terminal adapter Safety terminal fork terminal adapter 1 set containing 2 pieces red and black 257875 RJ Sensor For reference junction compensation sensor Pt100 Temperature measurement accuracy is 0 3 C High accuracy AC voltage 0 04 AC current 0 05 A To avoid electric shocks when using accessories do not touch the metal parts High stability AC voltage current 50 ppm h E Any company s names and product names mentioned in this document are trade names trademarks or registered trademarks of their respective companies Wide generation range AC voltage 1 00 mV to 1200 0 V AC current 1 00 mA to 60 00 A Yokogawa s Approach to Preserving the Global Environment e Yokogawa s electrical products are developed and produced in facilities that have received ISO14001 approval e In order to protect the global environment Yokogawa s electrical products are designed in accordance with Yokogawa s Environmentally Friendy Product Design Guidelines and Product Design Assessment Criteria Wide frequency range 40 to 1000 Hz Frequency accuracy 50 ppm model Description 2558A AC voltage current standard This is a Class A instrument based on Emission standards EN61326 1 and EN55011 and is designed for an industrial environment Operation of this equipment in a residential
4. text editor or Excel on PC Files can be easily transferred by drag amp drop operations when PC and 2553A is connected via a USB cable letting PC recognize the 2553A s internal memory as mass storage drive Sample files are available on our Website http tmi yokogawa com products generators source standard 2553a precision dc calibrator Calibrating and testing sensor transformers The 2553A calibrates the transformers and transmitters for pressure volume flow and temperature It also calibrates transformers for analytical instruments such as pH ORP EC and DO meters High voltage output accuracy of 2553A will enable support for transformers which require higher accuracy 2553A will come in use even in developing and testing transformers Simulating the two wire transmitters In 30 mA range the 2553A can sink the current For example by sinking the current from the distributors it can simulate the two wire transmitters which output 4 to 20 mA signals YOKOGAWA gt Drag amp Drop and copy a user defined file via USB cable l Voltage and resistance Temperature BOOO D7 O 2553A 16 000 mA OOOO 4 to 20 mA Distributor Specification Specifications Voltage generation 2553A Stability 1h Accuracy 180 days Accuracy 1 year HELGE source range EEE L Ae ppm of setting uV ppm of setting uV ppm of
5. 00 0 to 850 0 C 0 1 C 0 1 C 0 15 C 0 006 C C 0 5to2 mA Resistance generation Accuracy 180 days Accuracy 1 year ae Nominal Range Source Range Resolution ppm of eiting 0 ppm ot setting O Temperature Coefficient Curent 400 Q 18 00 to 400 00 Q 0 01 Q 55 0 015 75 0 015 0 002 0 C 0 5to2 mA 41 hour stability values apply at 23 1 C Accuracy values apply at 23 5 C Add the temperature coefficient at 5 C to 18 C and 28 C to 40 C Accuracy might be affected by instrument s inside temperature increase immediately after sinking over 30 mA YOKOGAWA Temperature generation for Thermocouple setting temperature Accuracy for 1 year C R S B J T See page 2 for source range gt gt Resolution 0 1 C _ 0C 0 80 00 75 600 C 0 70 100 C 0 11 200 C 0 29 _ Temperature scale is ITS 90 100 C 0 55 100 C 0 56 1000 C 0 50 0 C 0 08 100 C 0 16 Accuracy apply at 23 5 C and without reference oe ce a _ junction compensation _ 6000 0 40 4000 047 1200C 0 44 1200C 0 15 100C 0 10 Accuracy doesn t include the thermocouple s error 1600 C 0 40 1600 C 0 44 1820 C 0 44 400 C 0 09 Accuracy for temperature between setting on on temperature is calculated by linear interpolation Aceh Saat ee Accuracy not shown in left table is 60 ppm 4 uV E K N C A for generated voltage __ 250 C 0 50 250 C 0 94 240 C 1 00 0 C 0 30 0 C 0 34 3 RJC mod
6. 60 C specifications 9 Humidity 20 to 80 RH supported transfer modes High Speed Full Speed Operating Height 2000 m or less Ethernet interface Operating Attitude Horizon C i RJ 45 i Rated power supply voltage 100 to 120 VAC 200 to 240 VAC lectre 7 rarita aA A ectric and mechanica ee Conf to the IEEE 802 3 Ouse sins Supply 90 to 132 VAC 180 to 264 VAC specifications SE voltage fluctuation range o Onr vir z 50 60 Hz Transfer methods 100 BASE TX 10 BASE T power SuppYy trequency Transfer speed Max 100 Mbps Allowable power supply 48 to 63 Hz frequency fluctuation range GP IB interface Max power consumption 30 VA Electric and mechanical Complies with IEEE St d 488 1978 Between power and case specifications Withstand voltage 3 VAC 1 mi E cia Functional specifications PE ee alle neonate Dimensions 213 W x 132 H x 300 D mm p DC1 DT1 CO Weight Approx 3 kg Address 0 to 30 20 to 70 RH for 30 C and over Model and Suffix code Accessories Model Suffix code Description Model Product Specifications 2553A Precision DC Calibrator 1 m safety terminal cable with two leads E EAA 758933 Measurement lead red and black 1 set UC Deg C 758917 Measurement lead 0 75 m safety terminal cable with two leads ar cascade red and black one set eg C an 5 Te TEE 366961 Measurement lead 1 2 m Non isolated 42 V or less standard a a Small alligator clip Safety terminal alligator clip adapter F VDE st
7. Test Measurement YOKOGAWA lt Each click of a dial opens a doorway to precision 203A Precision DC Calibrator Bulletin 2553A 01EN Yokogawa is a leader in providing high precision measurement equipment electric voltage current electric resistance pressure and temperature fields A leadership that dates back to the early 1970 s Globally respected as the authority in developing and producing highly accurate and precision instruments and technology engineers can trust in first class quality and reliable performance The new Yokogawa 2553A is a precision DC calibrator ideal for calibrating measurement instruments including analog meters thermometers temperature transmitters and data loggers The 2553A delivers Yokogawa s attention to quality accuracy and precision ensures the engineer can trust in the product s reliability Ease of use and intuitive operation are a must for all engineers and dials for each digit and 7 segment LEDs makes the 2553A all the more simpler to use Flexibility and the availability of commonly used thermocouples RID generation and user defined functions enables an all in one instrument calibration Features and benefits High basic accuracy DC Voltage 75 pom DC Current 120 ppm High stability and low noise Stability 15 ppm h Noise 2 uVrms High resolution 5 5 digits 120000 count output resolution See Page 6 for details
8. andard 909A adapter 1 set containing 2 pieces red and black R AS standard 7 re 758924 Fork terminal adapter Safety terminal fork terminal adapter 1 set containing 2 pieces red and black H GB standard N NBR standard For reference junction compensation sensor Pt100 1 95 m 257875 RJ Sensor Standard accessories Power cord 1 366961 Measurement lead 1 Rubber feet 1 Terminal plug 1 User s manual 1 Rack Mount Model Product Description 751533 E3 Rack mount kit EIA standalone installation AOA ays 751533 J3 Rack mount kit JIS standalone installation 751534 E3 Rack mount kit EIA connected installation 758933 Measurement lead 758917 Measurement lead 751534 J3 Rack mount kit JIS connected installation 2 pieces red and black 1 set length 1 00 m 2 pieces red and black 1 set length 0 75m External dimensions Unit mm T 300 l 285 Related product AC Voltage Current Standard 2558A Used in combination with the 758921 or 758922 Rating 1000 V CAT III 19 A 366961 Measurement lead Non isolated 42 V or less 1 2 m 758922 A Small alligator clip adapter Safety terminal banana female to alligator clip adapter 2 pieces red and black in 1 set Rating 300 V CAT II
9. area may cause radio interference in which case users will be responsible for any interference which they cause YOKOGAWA lt gt YOKOGAWA METERS amp INSTRUMENTS CORPORATION Global Sales Dept Phone 81 42 534 1413 Fax 81 42 534 1426 Email tm cs jp yokogawa com tmi yokogawa com Subject to change without notice 2014 Yokogawa Meters amp Instruments Corporation YOKOGAWA CORPORATION OF AMERICA YOKOGAWA EUROPE B V YOKOGAWA ENGINEERING ASIA PTE LTD Phone 1 770 253 7000 Phone 31 88 4641000 Phone 65 62419933 Fax 1 770 254 0928 Fax 31 88 4641111 Fax 65 62412606 Ed 01 b Printed in Japan 409 KP
10. es 200 C 0 20 200 C 0 30 200 C 0 44 200 C 0 26 100 C 0 29 INT Detect temperature of output terminal as 100 C 0 10 100 C 0 15 100 C 0 21 600 C 0 25 600 C 0 28 compensation value Temperature measurement ee A accuracy is 0 3 C O C 0 07 OC 0 11 OC 0 16 1000 C 0 30 1600 C 0 47 EXT Detect compensation value by sensor 1000 C 0 12 800 C 0 15 800 C 0 15 2000 C 0 51 2500 C 0 79 connected to RJC terminal 1300 C 0 21 1300 C 0 20 ___2315 C 0 70 Hi a eel eaoa ene When using RJC add the reference junction compensation error in 2553A Temperature generation for Thermocouple Detail on our web site Other generation specification Rear panel Transient Voltage Current generation response time within 500 ms No load Time to reach 0 01 of final value RTD Resistance generation within 0 1 ms Time constant at changing current Max LC load C load 10 pF L load 1 mH CMRR Voltage 120 dB or more DC 50 60 Hz Current 0 1 uA V or more DC 50 60 Hz Ea RJ sensor connector terminal Bi Ethernet 2 USB interface 4 GP IB interface General specification Communication Interface Warm up time Approx 30 minutes USB interface PC connection Operating environment Temperature 5 to 40 C Connector Type B connector receptacle Humidity 20 to 80 RH Electric and mechanical Complies with USB Rev 2 0 PEREN AET Temperature 15 to
11. ince it generates higher accuracy voltage than previous model 2553A supports widely used Pt100 By setting temperature value it generates temperature related resistance value Settings can be done by not only temperature but also resistance value making it possible to calibrate using resistance value RJC at output terminals Since the 2553A has Internal RJC mode which the reference point is output terminals of 2553A it is possible to connect the objective measurement instruments by thermocouple without an external reference junction In External RJC mode your choice of Pt100 can be used with versatile terminal for external sensor It also has Manual RJC mode which enables you to set by entering reference value 2553A YOKOGAWA 60 000 mA sOOOO0OO 2553A Calibration by temperature value 120 0 C OOOO O 2553A Copper cables Calibration by resistance value BOOQOO OO 2553A Thermocouple RJC at output terminals of 2553A RJC at Input terminals External RJC mode of controller YOKOGAWA RJ sensor Calibration by temperature value Copper cables User defined temperature calibration The 2553A provides user defined thermocouple and RTD By copying text file including relation parameters between temperature and voltage or between temperature and resistance it is able to generate various types of thermocouple and RTD Text files can be easily created by
12. setting uV 10 mV 12 0000 mV 100 nV 20 3 40 4 60 4 100 mV 120 000 mV 1 pV 20 3 40 4 60 4 1V 1 20000 V 10 uV 5 10 40 10 60 15 10 V 12 0000 V 100 uV 5 100 40 100 60 150 30 V 32 000 V 1 mV 5 300 40 300 60 450 Bande Temperature Coefficient Max Output Output Output Noise g of setting pV C Typical Resistance 0 1 to10 Hz 10 Hz to 10 kHz 10 mV 10 0 1 Approx 1 Q 1 uVrms 10 uVrms 100 mV 5 0 3 lt 10 mA lt 10 mO 2 uVrms 10 uVrms 1V 3 1 5 120 mA lt 10 mO 2 uVrms 20 uVrms 10 V 3 15 120 mA lt 10 mO 15 uVrms 30 uVrms 30 V 3 45 30 mA lt 10 mO 20 uVrms 50 uVrms Current generation Stability 1h Accuracy 180 days Accuracy 1 year Range Source range Rasoio ppm of setting HA ppm of setting HA ppm of setting HA 1 mA 1 20000 mA 10 nA 5 0 015 50 0 03 80 0 04 10 mA 12 0000 mA 100 nA 5 0 15 70 0 4 100 0 5 30 mA 32 000 mA 1 yA 10 0 9 70 1 2 100 1 5 100 mA 120 000 mA 1 uA 10 3 70 4 100 5 Bande Temperature Coefficient Max Output Output Output Noise g of setting yA C Typical Resistance 0 1 to 10 Hz 10 Hz to 10 kHz 1mA 3 0 0015 15 V lt 100 MO 0 015 vArms 0 5 uArms 10 mA 5 0 015 15V lt 100 MO 0 03 pArms 1 pwArms 30 mA 7 0 045 30 V lt 10 MO 0 05 pArms 2 pArms 100 mA 10 0 15 15V lt 10 MO 0 3 pwArms 10 pwArms Temperature generation for RTD Accuracy Accuracy o Nominal Type Source Range Resolution 180 days 1year Temperature Coefficient Current Pt100 2
Download Pdf Manuals
Related Search
Related Contents
Skil 2598 AA Philips 3000 series Blu-ray Disc/ DVD player BDP3406 JVC KD-G301 CD Player User Manual NGS Chronus 700 ホームページアドレス [ http://a-rikujou.kuronowish.com/ ] IT SP DE FR EN Frigidaire FD27NKEC (NG) Grill A user's guide OSAKA CERA KEPI REV-29-07 Samsung SGH-E790 service manual Copyright © All rights reserved.