Home

USER MANUAL - Citygrow Energy Systems

image

Contents

1. s products CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL user to the presence of uninsulated dangerous voltage within the product s enclosure that may The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the A be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Oa IMPORTANT SAFETY INSTRUCTIONS READ BEFORE OPERATING EQUIPMENT This product was designed and manufactured to meet strict quality and safety standards There are however some installation and operation precautions which you should be particularly aware of ee eS a E 10 11 12 13 14 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat Do not defeat the safety purpose of the pola
2. C G2 crates po ts ects ots ects io ts ets os ots os ots Ges oes Go ts oes Gos ote we 8 7 2 CG111DM GT ccc cect pect chet tect cee pect tect pect cto ants stots tects ctects eects tease 9 Ts OG ACCP sacs ace ace werctinre sare leds vee tecte secs ee ceuecsceceseceueecueseuecetece 10 7 3 1 Setting the open and close travel distant for the curtain 12 Adding the product to your Home Wireless ZigBee Network csceeeeeneees 14 SP Bt CAN ee acest ace ic ee we ces een pe stn dee aden ne nina a alse en eae eee eee ee eee eens 15 1 Introduction Thank you for buying Citygrow s product CG111 Series is both powerful and easy to use and install It is specially designed for French wall box installation It is for wireless remote control Home Automation purpose Description 10 11 12 13 14 15 16 ZigBee wireless remote control Based on IEEE 802 15 4 2 4GHz radio frequency CG111S1 S2 DM is for lighting control CG111S2 CCP is for control of electronic curtain or window blind C G111S2 H4 is Mood control panel for scene setting built in with two gang switch CG111DM H4 is Mood control panel for scene setting built in with one gang dimmer LED indicator for on off status Load loads are directly driven by the build in driver Control button can be configured to become two way function Control button can be configured to become scene function Support iPhone iPad an
3. CG 1 1 1 S E RI ES FRENCH WALL BOX INSTALLATION ZIGBEE WIRELESS SWITCH USER MANUAL A CG111S1 CG111S2 CG111S2 H4 CG111S2 CCP One Gang Switch Two Gang Switch 4 Button Mood Panel One Gang Curtain With Two Gang Switch Control Switch AN Vv CG111DM CG111DM H4 One Gang Dimmer 4 Button Mood Panel With One Gang Dimmer French wall box VERSION 0 0 ST APRIL 2014 CityGrow Systems Disclaimers and Copyright Nothing contained in this publication is to be construed as granting any right by implication or otherwise for the manufacture sale or use in connection with any method apparatus or product covered by letters patent or as insuring anyone against liability for infringement of letters patent Efforts have been made to ensure the accuracy and reliability of the data contained in this publication however Citygrow Energy Systems Limited makes no representation warranty or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or from the use of any product or methodology described herein for any violation of any federal state or municipal regulation with which this publication may conflict or for the infringement of any patent from the use of this publication Nothing contained in this publication should be viewed as an endorsement by Citygrow Energy Systems Limited of any particular manufacturer
4. E 2 4GHZ 2 4GHZ 15 CityGrow Systems CG11151 CG111 2 CG111DM CG11132 CCP CG11152 H4 CG111DM H4 Description One Gang Two Gang One Gang One Gang Switch Switch Dimmer Curtain Control Leading Edge Switch Dimming Resistive load SOOW gang 200W 1 Incandescent 2 Halogen 3 Electronic low voltage ELW transformer Inductive load S0OVA gang 1 Magnetic low voltage MLY transformer 2 lron core Inductive transformer O Compact fluorescent CFL 200W gang Dimmable CFL Max 12 pcs Max 10 pcs CFL Gang CFL LED GU10 100W gang LED MR16 MR11 200W gang With electronic low voltage LED driver aie ELV LED driver iang LED strip 200W gang With electronic low voltage driver Max 5 pes ELV LED driver Gang Exhaust fan 200VA gang 3 wire type AC curtain motor Minimum load TECHNICAL INFORMATION AND PICTURES SUBJECTED TO CHANGE WITHOUT PRIOR NOTICE Copyright 2012 Ctiygrow Energy Systems Ltd All Rights Reserved 16
5. ET Planner Software STEP 4 Refer to the user manual of HomeNET Planner Software to program and set the address of the product Systems 9 Specification CG611151 CG11132 G1110M CG11132 CCP C611132 H4 G6111DM H4 Description One Gang Two Gang One Gang One Gang Curtain switch Switch Dimmer Control Switch iLeading Edge Dimming Operating voltage AC220 240V 50Hz Maximum number of devices included in scene setting Remarks 1 2 Remarks When up button is used for dimming up function the down button cannot be programmed as scene function Maximum number of devices programmed into the whole product is limited to 50 devices The maximum load requirements for fluorescent CFL and LED loads can vary greatly depending upon the specific dure and Jor bulb being used When dimming transformer is connected fo CG111 make sure dimmable and leading edge type is used Furthermore the dimming performance varies greatly fram manufacturer to manufacturer of the bulb and the dimming transformer It is recommended to test the matching performance before mass deployment fa ee Minimum dimming level Ho setting Memor dim function B EIES 100M 100m1 ooxooMa ooxooua 0 to 40 degt 0 to 40 degt Remote control distance 100M 100M iM line of sight Dimensions mm Length x coxooxd gt poco pa o e Width x Depth Recommended operation Oto 40 degt temperature RF frequency 2 4GHZ 2 4GHZ
6. age to control units or other equipment Always turn off circuit breaker or remove main fuse from power line before doing any work To avoid overheating and possible damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transformers that incorporate thermal protection or fused primary windings This product is designed for residential and commercial use for indoor use only WARNING Install in accordance with all national and local electrical codes IMPORTANT Citygrow is not liable for any damage incurred with the misuse of this product IMPORTANT Pre setup can only be done by a professional worker or manufacturer agent 5 Wiring CGi11S2 CCP Neutral Conduit _ Ac Live Curtain motor AC S2 l ANANAN i Wall box Wall Distribution panel MAS AAAS NA OB 1 18 1 a o a a a Conduit Wall box VAS AYN CG111S2 CCP Before getting started WARNING It must be installed by a qualified electrician in accordance with all applicable regulations and building codes Improper wiring can result in personal injury or damage to control units or other equipment Always turn off circuit breaker or remove main fuse from power line before doing any work To avoid overheating and possible damage to equipment WARNING Do not operate when any lamps removed or burned out replace any burned out lamps immediately use only transf
7. and close travel distant for the curtain The function of the Learning Mode in the CG111S2 CCP is to program the duration of the curtain Opening Closing time In order to perform the Learning Mode function please follow the below steps STEP 1 Press the CLOSE Button until the curtain is fully closed NOTE You may have to press the Button once or more times in order for the curtain to be fully closed STEP 2 aes Press and HOLD the Reset Button While still holding the Reset Button press and HOLD the Open Button STEP 3 CLOSE Release the Reset Button Wait until the LED Indicators begins BLINKING Release the Open Button NOTE The curtain should be opening at this point STEP 4 CLOSE Once the curtain is fully opened press and release any Button NOTE The duration of the Opening Closing time will be stored once the Button is pressed STEP 5 OPENe CLOSE Use a thin object to press the Reset Button again The learning process of the CG111S2 CCP has now finished 13 8 Adding the product to your Home Wireless ZigBee Network 14 STEP 1 Open the front cover you will see a 5 pin connector STEP 2 Plug the CG101UT5 cable into the 5 pin connector of the product and then plug the other end of the CG101UT5 cable into the mini USB end of the CG101UTC cable STEP 3 Plug the CG101UTC cable into the USB port of a PC that is installed with Citygrow s HomeN
8. d Android mobile control if CG102BS Base station is purchased Control button graphics can be tailor made per customer requirement Mounted in a standard UK wall box No EIB Bus required Easy to install 2 Understanding of the product Control button Button panel Front view Control unit button panel lock Contacts for button panel Load terminals CG111S1 One Gang Switch CG111S2 Two Gang Switch CG111S2 H4 4 Button Mood Panel with Two Gang Switch CG111DM One Gang Dimmer CG111DM H4 4 Button Mood Panel with One Gang Dimmer CG111S2 CCP One Gang Curtain Control Switch Button panel Rear view Programming port Metal clip to fix the Control unit bottom view Motor Motor Neutral Live Backward Forward terminals 3 Dimensions CG111S2 85mm l 42mm 4 Wiring CG111S1 CG111S2 CG111S2 H4 CG111DM CG111DM H4 Notes The Neutral wire of load is closely connected to the Neutral point of CG111 Situation 1 Live Neutral and Load wires are ready at wall box Wall box Distribution panel Situation 2 Live and Load wires are ready at wall box Neutral wire is only ready at ceiling Neutral Load E Wall box Live Distribution panel Before getting started WARNING It must be installed by a qualified electrician in accordance with all applicable regulations and building codes Improper wiring can result in personal injury or dam
9. ormers that incorporate thermal protection or fused primary windings This product is designed for residential and commercial use for indoor use only WARNING Install in accordance with all national and local electrical codes IMPORTANT Citygrow is not liable for any damage incurred with the misuse of this product IMPORTANT Pre setup can only be done by a professional worker or manufacturer agent 6 Installation In order to install the product correctly please follow the below steps STEP 1 IMPORTANT Turn off main power at the main switch board ONIONIONION JO NONO ONION SBAS B88 B8 OFFPFFPFFDFFE prFrAorApFA OFFIOFA STEP 2 Loosen the screws of the original wall switch Remove the switch and disassemble the wiring STEP 3 Connect the main power cable to the Live and Neutral terminals and the load cable to the Load terminals at the rear cabinet of the product STEP 4 Fasten the screws of all terminals and check that the wires are properly secured Retrofit the switch into the standard switch box and mount it on the wall by fastening the two screws at the rear of the switch box Screw x 2 pcs CG111 button panel Make sure the button panel is locked into the power unit STEP 5 Push the ON OFF button to test whether the wiring has been connected correctly If the ON OFF Button does not function as expected please check the wiring connection again Notes Use standard French type wall b
10. ox During installation of the wall box it is recommended to embed the wall box deeper inside the wall in order to give more room to install the product 7 Operation instruction 7 1 CG111S1 CG111S2 CONTROL PANEL LED Indicator ON OFF Button Program port Metal clip Mounting hole Press ON OFF Button once to toggle between ON and OFF BRIGHT LED indicates that the Switch is ON DIMMED LED indicates that the Switch is OFF 7 2 CG111DM CG111DM H4 CONTROL PANEL Dim Up LED Indicator Dim Down LED Indicator Program port Metal clip Mounting hole Press the Dim Up Dim Down button ONCE to Toggle between ON and OFF LED FLASHING indicates that that the Button was pressed and dimming is in progress When the LED stops flashing it indicates that the dimming is complete Press and HOLD the Dim Up Dim Down button to begin dimming Release the button at desired level 7 3 CG111S2 CCP CONTROL PANEL OPEN CLOSE POWER MODULE 10 1 Open button 2 Close button 3 Program port 4 Metal clip 5 Mounting hole Press the Open Close Button once to control the electric curtain When the electric curtain is stopped press the OPEN button to open the electric curtain When the electric curtain is stopped press the CLOSE button to close the electric curtain When the electric curtain is running press ANY button to stop the electric curtain 11 7 3 1 Setting the open
11. rized or grounding type plug If the provided plug does not fit into your outlet consult an electrician for replacement of the outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Table of content L Jalie ia Deno cx sider E E A E E 1 Understanding of the product cccccscecseeeeeeeeeeeeeeeeeeaeeeeseaeeeeaeaeeeeeeaeeeseeaenes 2 Bi en ea E E E E E 3 Wiring CG111S1 CG111S2 CG111S2 H4 CG111DM CG111DM H4 000 3 WINN Gib S2 CP oes orders ccc as pce se pnd pnd ee pnd pe epee ee epee 5 UTS Ue WAU Ol cece cede vncsecennaesie en cactsied sacaseee E E E T 6 Operation iINStruction ceeece ce cececere cececececececedscecscedssecssedssecscecssecscecscecseucssecseucese 8 7 1 G

Download Pdf Manuals

image

Related Search

Related Contents

Furuno 16 Cell Phone User Manual  SBB - English Manual - Heat Recovery Ventilators, Air Handlers      NewAir G70 User's Manual  Minifant M99 - Naturalia BAU  NEC EA224WMI-BK LED display  044 HD manual  Behringer Micromon MA400 User's Manual  Pharos Science & Applications 135 User's Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.