Home

MODEL GT15V-75ROUT RGB Output Unit User`s Manual

image

Contents

1. 3 6 GOT main unit 133 5 24 3 0 12 APULL S E D se Ya tol co eo vj al lt 7 9 az oS e 6 25 0 10 1 X EE ay FERS mal Y T 8 5 0 33 Mean 2 4 Dimensions of X when the RGB output unit is mounted to the GOT 12 1 18 0 71 10 4 21 0 83 Unit mm inch Description Connector for RGB output Connector for connecting a 9 core combined cable Interface connector Connector mounted to the GOT Extension connector Connector to which a back extension unit is installed Connector for video RGB Connector connecting with the video RGB interface of connection GOT Board fixing screw Screw for fixing the extend interface relay board Mounting screw Mounting screws for fixing the unit to the GOT Rating plate 2 Extend interface relay board TESO O 27 5 1 08 Unit mm inch 4 INSTALLATION PROCEDURE The installation procedure for the RGB output unit is explained using the GT1575 1 Power off the GOT 2 Remove two extension unit covers of the GOT 3 Attach the extend interface relay board to the extend I F 2 side on the GOT After the installation detach the connector cover from the extend interface relay board 4 Fit the RGB output unit in the GOT case Remove the connector cover 5 Fasten the RGB o
2. HSYNC VSYNC Horizontal Vertical sync sync width width i 0 607ms e 2 190 us 0 106ms Vertical sync 3 206 Us Horizontal sync 26 406 us 16 583ms RGB external connection D Sub15 pin method Applicable wire size 9 core combined cable recommended Internal current consumption 5VDC 0 11A Weight 0 16 kg 0 35 Ib 2 2 Specifications of the cables 9 core combined cables used when connecting the external display 1 Cable specifications Applicable connector 15 pin D sub for both ends 2 Connection diagram GOT side 750 coaxical CRT side Lf x e pU ME e i 1 R i l T 6 RGND HeT e H HL GGND fp B i 8 BGND f i 10 GND i X 13 HSYNC i 1 14 VSYNC T 5 GND r DX 4 GND 9 NC Twisted pair i 11 GND i 12 SDA 15 SCL lt ESA KU UP aa as eee TEESE J a te 3 Connector GOT connector Use the connector matching the following model for the GOT 15 pin D sub male inch screw type Manufactured by DDK 17HE R13150 73MC2 Connector at the display Use the connector applicable to the display 3 PART NAMES AND EXTERNAL DIMENSIONS 1 Part names and external dimensions of the RGB output unit
3. A8 SXHIEASI2IgA EAE LE ASAE Ol SS FLSA Her HAAA ASMA ASSE AS SAO g SUC The product is for business use Class A and meets the electromagnetic compatibility requirements The seller and the user must note the above point and use the product in a place except for home A 7 1 OVERVIEW This User s Manual describes the GT15V 75ROUT RGB output unit hereinafter referred to as the RGB output unit When mounting RGB output unit with GT1585V STBA and GT1575V STBA hereinafter collectively referred to as the GOT the RGB output unit can external display screens on GOT 8l J c GOT GT15V 75ROUT External display To use the RGB output unit make the Communication Settings For setting details refer to GOT1000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT Works3 For details of system configuration refer to GOT1000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT Works3 2 SPECIFICATIONS 2 1 RGB output unit Item Specifications RGB output i method dot s Analog RGB SVGA 800x600 Number of RGB output 1 channel channels Dot clock 38 362 MHz Horizontal scanning 37 87 kHz frequency Vertical scanning 60 30 Hz frequency Horizontal synchronizing timimg Vertical synchronizing timimg Vino sional Video signal RGB l HS RGB 15 844ms analog analog 0 7Vp p 0 7Vp p Timing chart
4. Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 Mitsubishi Italy Mitsubishi Electric Europe B V Italian Electric Building Singapore 159943 Branch Tel 65 6470 2460 Centro Dir Colleoni Pal Perseo Ingr 2 Thailand Mitsubishi Electric Automation Thailand jl 20041 3 Co Ltd Via Paracelso 12 20041 Agrate Brianza Bang Chan Industrial Estate No 111 Milano Italy cr Per Moo 4 Serithai Rd T Kannayao 1 Tel 439 039 60531 A Kannayao Bangkok 10230 Thailand Spain Mitsubishi Electric Europe B V Spanish Tel 466 2 517 1326 Branch Indonesia P T Autoteknindo Sumber Makmur Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Barcelona Spain Per i gudangan Jakarta Utara 14440 Tel 34 93 565 3131 P O Box 5045 Jakarta 11050 Indonesia France Mitsubishi Electric Europe B V French Tel 62 21 6630833 Branch i s India Messung Systems Pvt Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO III Unit No15 Nanterre Cedex France M I D C Bhosari Pune 411026 India A Tel 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 AM MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNO
5. MITSUBISHI MODEL GT15V 75ROUT RGB Output Unit User s Manual Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15V 75ROUT U MODEL CODE 1D7M55 IB NA 0800349 F 1111 MEE GRAPHIC OPERATION TERMINAL GOTiooo eSAFETY PRECAUTIONSe Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION 3 Indicates that incorrect handling may cause hazardous D DANGER conditions resulting in death or severe injury I l Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal I 1 A CAUTION injury or physical damage I Note that the A caution level may lead to a serious accident according to the circumstances Always follow the instructions of both levels because they are important to personal safety Please save this manual to make it accessible when required and always forward it to the end user A 1 DESIGN PRECAUTIONS N CAUTION Do not bunch the control wires or comm
6. UCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permissioi Specifications subject to change without notice Printed in Japan November 2011
7. hen connecting the external display ao 3 PART NAMES AND EXTERNAL DIMENSIONS eee 4 4 INSTALLATION PROCEDURE senes 6 A 6 Manuals The following shows manuals relevant to this product Detailed Manual Model code GT15 User s Manual SH 080528ENG Sold separately 1D7M23 GOT1000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT Works3 Sold separately SH 080871ENG 1D7MC5 Relevant Manuals For relevant manuals refer to the PDF manuals stored in the CD ROM for the drawing software used Packing List The following items are included Product Quantity RGB output unit GT15V 75ROUT Mounting screw set 2 screws 2 stickers Extend interface relay board Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT EMC and Low Voltage Directives compliant into other machinery or equipment refer to EMC AND LOW VOLTAGE DIRECTIVES of the General Description included with the GOT used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the GOT Compliance with the Radio Waves Act South Korea This product complies with the Radio Waves Act South Korea Note the following when using the product in South Korea 0 JAE 8S8
8. or the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation A 4 REVISIONS The manual number is noted at the lower right of the top cover Print Date Manual Number Revision Mar 2006 IB NA 0800349 A First edition Feb 2007 IB NA 0800349 B Partial addition Chapter 1 Addition Compliance with the EMC and Low Voltage Directives IB NA 0800349 C Partial correcitions Compliance with the EMC and Low Voltage Directives Chapter 2 3 4 Jun 2009 IB NA 0800349 D Partial correcitions Compliance with the EMC and Low Voltage Directives Jun 2011 IB NA 0800349 E Addition Compliance with the Radio Waves Act South Korea Nov 2011 IB NA 0800349 F Partial correcitions Chapter 2 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2006 MITSUBISHI ELECTRIC CORPORATION A 5 CONTENTS 1 OVERVIEW t ER tr ere E ERE RAS PDA RARE PERRCE 1 2 SPECIFICATIONS 2 1 RGB output unit 2 2 Specifications of the cables 9 core combined cables used w
9. tor of unit Incorrect connection may cause malfunctions Do not hold the cable by hand and pull it out from the unit When removing the cable from the unit make sure to hold the connector by hand and pull it Failure to do so may cause malfunctions or damage to the unit or cable A 3 STARTUP MAINTENANCE PRECAUTIONS When power is on do not touch the terminals Doing so can cause an electric shock or malfunction Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire Do not drop the module or subject it to strong shock A module damage may result Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the unit to fail or malfunction DISPOSAL PRECAUTIONS NCAUTION When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS N CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual f
10. tric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Brazil MELCO TEC Rep Com e Assessoria Tel 852 2887 8870 Tecnica Ltda China Mitsubishi Electric Automation Rua Correia Dias 184 China Ltd Edificio Paraiso Trade Center 8 andar AIF Zhi Fu Plazz No 80 Xin Chang Road Paraiso Sao Paulo SP Brazil Shanghai 200003 China Tel 55 11 5908 8331 Tel 86 21 6120 0808 Germany Mitsubishi Electric Europe B V German Taiwan Setsuyo Enterprise Co Ltd Branch 6F No 105 Wu Kung 3rd Rd Wu Ku Gothaer Strasse 8 D 40880 Ratingen Hsiang Taipei Hsine Taiwan GERMANY Tel 886 2 2299 2499 Tel 49 2102 486 0 Korea Mitsubishi Electric Automation Korea Co Ltd U K Mitsubishi Electric Europe B V UK 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Branch Travellers Lane Hatfield Hertfordshire Tel 482259060 9552 AL10 8XB U K Singapore Mitsubishi Electric
11. unication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100mm 3 94 inches otherwise malfunctions may occur due to noise MOUNTING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit onto from the GOT Not doing so can cause the unit to fail or malfunction Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT used Not doing so can cause an electric shock fire malfunction or product damage or deterioration Tighten the mounting screws within the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure A 2 WIRING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions N CAUTION Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction Make sure to securely connect the cable to the connec
12. utput unit by tightening its mounting screws 4 places with tightening torgue 0 36 to 0 48 Nem 6 Fasten the bus connection unit by tightening the board fixing screws 2 places with the tightening torque of 0 36 to 0 48 Nem 7 When installing an extension unit on the unit that has been installed remove the connector cover and the sticker When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mounting screws 4 places Keep the connector cover fixed Keep the sticker stuck as it is Connector cover Accessory sticker Accessory sticker Point Remove the screws that fixes the extend interface relay board before removing the unit Above 6 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties NFor safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power elec