        NI 9514 Operating Instructions and Specifications
         Contents
1.   Digital logic levels  ON state   Input voltage oe 11 to 30 V   Input current    22 mA    Digital input configured for sourcing  Digital logic levels  OFF state  Input voltage oo    eee 11 to 30 V  Input current     lt l mA  Digital logic levels  ON state  Input voltage       Input current    28   nicom   NI9514 Operating Instructions and specifications    MEP BE nissene Contact NI for Bellcore  MTBF or MIL HDBK 217F  specifications     Power Requirements  Power consumption from chassis    Active mode         eee seeeeereeeeteee 900 mW max  Sleep mode sans 0 4 mW max  Thermal dissipation  at 70   C   Active mode           ieeeeeeseeeessesssees 1 5 W max  Sleep mode    0 4 mW max  NI 9514 Input and Output Characteristics  Voup INPUT    19 to 30 V  150 mA max   5 V regulated output    5 V 5   150 mA max            Assumes the minimum filter setting  Refer to the NI SoftMotion Module book of the  LabVIEW Help for more information about filter options     NI 9514 Operating Instructions and specifications      National Instruments   29    Physical Characteristics  If you need to clean the module  wipe it with a dry towel     DE Note For two dimensional drawings and  three dimensional models of the C Series module and  connectors  visit ni com dimensions and search by  module number     MWelohtsi shimnnnmnane sin 155 g  5 5 oz   Safety  Safety Voltages  Connect only voltages that are within the following limits   Channel to COM      iiiieeeeeseeseeerseees 0 to  30 VDC max   Measur
2.  422 differential or    single ended inputs    NI 9514 Operating Instructions and specifications      National Instruments   23    Digital logic levels  single ended       Voltage isisisi  0 25 to 5 25 V  High  Vip 2 0 V min  LOW  V eee ER 0 8 V max   Digital logic levels  differential  Phase      Phase      Input high range    300 mV to 5 V  Input low range eee  300 mV to  5 V  Common mode voltage          7 to 12 V   Input current at 5 Vo   1 mA   Min pulse width   Differential            Single ended  Max count rate  Differential    20 x 106 counts sec    Single ended 0 0    eee 5 x 106 counts sec         Common mode voltage is the average of Phase  and Phase      2 Assumes the minimum filter setting  Refer to the NJ SofiMotion Module book of the  LabVIEW Help for more information about filter options     24   nicom   NI 9514 Operating Instructions and specifications    Forward  reverse  and home inputs  Input type    Software selectable  sinking  or sourcing  Limit or home input configured for sinking  Digital logic levels  OFF state       Input voltage          eeeeeeeeeeeee  lt 5 V   Input current     5250 WA  Digital logic levels  ON state   Input voltage          eeeeeeeeeeeee 11 to 30 V   Input current     gt 2 mA    Limit or home input configured for sourcing  Digital logic levels  OFF state    Input voltage 0    eee 11 to 30 V   Input current     lt l mA  Digital logic levels  ON state   Input voltage oo    eee  lt 5 V   Input current    22 mA    NI 9514 Operating 
3.  Home        Reverse Limit    11  1 Forward Limit             10   nicom   NI9514 Operating Instructions and specifications    Figure 3  NI 9514 37 Pin Terminal Block Pin Assignments                Forward Limit m                   Home i       HIL             COM a             Le   02   6L                Digital Input 0  gt     I                      COM S                      Encoder 0 Index  io                Encoder 0 Index    i                COM                6     5V OUT             ME       Position Compare          LE  OL                      Reserved                      eb    Drive Commandt    il    RIBIRIRIRIRIRIRBIRIRIRIE                Reserved          LE   OE   6Z   82   ZZ   92   SZ   te     2   zz          HI    Vsupt                         Digital Input 1t                         Ak    Reserved                   comt                            JL    Reserved                                  GND  8L  ZE  9L  St  pL  Eb    Shield  I                BIBIRIHIRIRIH                      LE   9      SE   ve   E     ZE                BIRMIRBIRIBIRIRIRIRHIRIBIRIRIRIRMIRIRIRIR          fIndicates DSUB connector signals     NI 9514 Operating Instructions and specifications    Reserved   Reverse Limit  Reserved   Vsup   Reserved   COM   Encoder 0 Phase A   Encoder 0 Phase A     Encoder 0 Phase B   Position Capture  Encoder 0 Phase B   Reserved   Drive Command COMt  comt   Drive Enablet  Reserved   Reserved   Reserved   Reserved       National Instruments   11    Signa
4. 16  C Series Drive Interface Modules and AKD Analog Servo  Drives for installation and configuration information   Refer to the Getting Started with NI 951x C Series Drive  Interface Modules and LabVIEW for information about  using the NI 9514 with other devices     How to Connect the NI 9514 to Drives and I O  Complete the following steps to connect the NI 9514 servo drive  interface module to drives and other I O     1  Install the module in the chassis as specified in the chassis  documentation     Note Refer to the MI SoftMotion Module book of the  LabVIEW Help for information about chassis  slot  or  software restrictions     2  Connect the module to a drive and other I O using the  NI 9514 16 to AKD cable  the NI 951x Cable and Terminal  Block Bundle  or a custom cable for direct connectivity to  third party drives     6   nicom   NI9514 Operating Instructions and specifications    3  Connect the NI 9514 module to an external power supply     Caution Do not connect anything to pins marked  Reserved     DE Caution The 37 pin terminal block has separate V sup  and COM terminals for each connector  Make sure you  are using the correct V    and COM terminals for the  connector you are using  All signals associated with  the DSUB connector in Figure 3 are marked with a    dagger  f      Figure 1 shows a simplified system connection diagram     NI 9514 Operating Instructions and specifications      National Instruments   7    Figure 1  NI 9514 Connection Example         DSUB 
5. 74988E 01 Dec13    
6. Circuit Configured for Sinking       PNP  Sourcing                                         NI 9514 Input Device   i V  i   1 1 1   i NI 9514 Vsup   i t  1 1 1   A   1  Sourcing           Circuit      i    Drive Enable    In i     Drive Enable   1 1   p     1 1       1 1   Configured I i   i For Sinking 1  y  j     COM   j Reference       18   nicom   NI9514 Operating Instructions and specifications    LED Indicators  The NI 9514 has four LEDs to display status information     T  1414     OOC                   1 Axis Status  Green  3 Limit Active  Yellow   2 Encoder Active  Green  4 Axis Fault  Red   Axis Status    The Axis Status LED  green  has three states to display axis status        Off   The module is in sleep mode or failed to boot correctly   Refer to the NI SoftMotion Module book of the LabVIEW Help  for troubleshooting information        Flashing   The module booted up correctly and is functional     e Lit   The module is functional and the drive enable output is  active     NI 9514 Operating Instructions and specifications      National Instruments   19    Encoder Active  The Encoder Active LED  green  has three states for encoder and    V sup Status     e Off   the required power supply  Viup  is not connected  You  must connect a power supply to receive encoder pulses     e Flashing   The power supply  Vu  is connected and the  module is receiving encoder pulses     DE Note The LED flash rate does not correspond to the rate  at which the NI 9514 receives encoder 
7. Connector MDR Connector  Drive Command  gt O   Encoder 0 Phase A  B  Index                    gt O   Forward  Reverse Limit  Home                1  i  Drive Enable O   5V OUT  i  i       o        gt O   Drive Fault   TO             Limit and Home    i  NI Connection i  Sensors     i    Accessory   Custom Cable                    gt   Drive Command   gt   Drive Enable             Drive Fault                i      i     1  Drive i  f   1   f                   i i  i 1  f    i i  f      Motor i  f    f 1  i f       f 1    Servo Motor Encoder    8   nicom   NI 9514 Operating Instructions and specifications    Table 1  NI 9514 DSUB Connector Pin Assignments                                                                Connector Pin Signal  1 Drive Command  COM  2 Drive Enable  3 Reserved  gs 4 Reserved  o 5 Reserved  6 Drive Command  CR 7 COM  8 Digital Input 1  9 Reserved     _    10   Reserved  11 Reserved  12 Voup  13 Reserved  14   COM                NI 9514 Operating Instructions and specifications      National Instruments    9    Figure 2  NI 9514 MDR Connector Pin Assignments                                                       4 Encoder 0 Phase B     20 10    Position Compare  Op Position Capture    19  9  5 V OUT       Encoder 0 Phase B     18 8   COM  es i Encoder 0 Phase A     17  7 Encoder 0 Index     om   1 Encoder 0 Phase A     16  6 Encoder 0 Index   5    i COM    15 5    COM  4 k Reserved    14  4 Digital Input 0  o F   7 Veup   13  3    COM  y Reserved    12  2
8. Instructions and specifications      National Instruments   25    Min pulse width  50 us    Position capture input  Digital logic levels             Voltage        iieeeeeesseesseessssenss  0 25 to 5 25 V  High  Viy 2 0 V min  Low  Vi    0 8 V max   Input current    0 V  lt  Vin S4 5 VV      2 mA max   Min pulse width  0    100 ns   Max capture latency        sseseseee 200 ns   Capture aCCuracy ou    eee eee  1 count   Active edge Software selectable  rising   edge or falling edge  Position compare outputs   High  Vos 5 25 V max   Sourcing 12 mA    3 7 V min       Sourcing 4 mA         Assumes the minimum filter setting  Refer to the NI SoftMotion Module book of the  LabVIEW Help for more information about filter options     26   nicom   NI 9514 Operating Instructions and specifications    Low  Vor    Sinking 12 MA    0 7 V max  Sinking 4 MA    0 5 V max  Compare mode   s   Software selectable   single or periodic  Compare action cece Software selectable   set  toggle  or pulse  Max compare rate  periodic        5 MHz  Pulse width  programmable   Miniset 100 ns  Maximin 1 6 ms  Active state    Software selectable   high or low    Digital Inputs  Number of inputs        eereeeereeeeenseerese 2     Inputity pesis eee Bak Saeed Software selectable   sinking or sourcing    NI 9514 Operating Instructions and specifications      National Instruments   27    Digital input configured for sinking  Digital logic levels  OFF state    Input voltage oe eee SV   Input current     lt 250 pA
9. OPERATING INSTRUCTIONS AND SPECIFICATIONS    NI 9514    Servo Drive Interface Module with Encoder Feedback             Frangais Deutsch AG ESH MARP    ni com manuals                                           NATIONAL  INSTRUMENTS    This document describes how to use the National Instruments 9514  module and includes specifications and pin assignments for the  NI 9514     DE Note The safety guidelines and specifications in this  document are specific to the NI 9514  The other  components in the system may not meet the same safety  ratings and specifications  Refer to the documentation for  each component in the system to determine the safety  ratings and specifications for the entire system     Related Information       NI CompactRIO Documentation  ni com info   cseriesdoc    Chassis Compatibility  ni com info    compatibility    Software Support ie Services  Ld          ni com info   rdsoftwareversion ni com services    2   nicom   NI9514 Operating Instructions and specifications    Safety Guidelines       Operate the NI 9514 only as described in these operating  instructions     Hot Surface This icon denotes that the component may  be hot  Touching this component may result in bodily    injury   Special Conditions for Marine Applications    Some modules are Lloyd   s Register  LR  Type Approved for  marine applications  To verify Lloyd   s Register certification  go to  ni com certification and search for the LR certificate  or  look for the Lloyd   s Register mark on the m
10. asurement  control  and  laboratory use     e EN 61326 1  IEC 61326 1   Class A emissions  Industrial  immunity       EN 55011  CISPR 11   Group 1  Class A emissions  e AS NZS CISPR 11  Group 1  Class A emissions   e FCC 47 CFR Part 15B  Class A emissions   e ICES 001  Class A emissions    DE Note For the standards applied to assess the EMC ofthis  product  refer to the Online Product Certification section     DE Note For EMC compliance  operate this device with  double shielded cables     32   nicom   NI9514 Operating Instructions and specifications    CE Compliance C        This product meets the essential requirements of applicable  European Directives as follows     e 2006 95 EC  Low Voltage Directive  safety     e 2004 108 EC  Electromagnetic Compatibility Directive   EMC     Online Product Certification    Refer to the product Declaration of Conformity  DoC  for  additional regulatory compliance information  To obtain product  certifications and the DoC for this product  visit ni   com   certification  search by module number or product line  and  click the appropriate link in the Certification column     Shock and Vibration  To meet these specifications  you must panel mount the system   Operating vibration  Random  IEC 60068 2 64           5 ging 10 to 500 Hz  Sinusoidal  IEC 60068 2 6          5 g  10 to 500 Hz    NI 9514 Operating Instructions and specifications      National Instruments   33    Operating shock   IEC 60068 2 27                           30 g  11 ms 
11. ement Category I  Isolation  Channel to channel               0 None  Channel to earth ground  Continuous        iiieeeeereeseeseses 30 VDC   Measurement Category I  Withstand 0 0    cece 500 Vims Verified by a 5 s    dielectric withstand test    30   nicom   NI 9514 Operating Instructions and specifications    Measurement Category I is for measurements performed on  circuits not directly connected to the electrical distribution system  referred to as MAINS voltage  MAINS is a hazardous live electrical  supply system that powers equipment  This category is for  measurements of voltages from specially protected secondary  circuits  Such voltage measurements include signal levels  special  equipment  limited energy parts of equipment  circuits powered by  regulated low voltage sources  and electronics     Caution Do not connect the NI 9514 to signals or use  for measurements within Measurement Categories II  III   or IV    Safety Standards    This product meets the requirements of the following standards of  safety for electrical equipment for measurement  control  and  laboratory use       IEC 61010 1  EN 61010 1  e UL 61010 1  CSA 61010 1    DE Note For UL and other safety certifications  refer to the  product label or the Online Product Certification section     NI 9514 Operating Instructions and specifications      National Instruments   31    Electromagnetic Compatibility    This product meets the requirements of the following EMC  standards for electrical equipment for me
12. half sine   50 g  3 ms half sine   18 shocks at 6 orientations    Environmental    National Instruments C Series modules are intended for indoor use  only  but may be used outdoors if installed in a suitable enclosure   Refer to the manual for the chassis you are using for more  information about meeting these specifications     Operating temperature   IEC 60068 2 1  IEC 60068 2 2         40 to 70   C    Storage temperature   IEC 60068 2 1  IEC 60068 2 2        40 to 85   C    Ingress protection    IP 40   Operating humidity    IEC 60068 2 56                            10 to 90  RH   noncondensing   Storage humidity    IEC 60068 2 56                            5 to 95  RH   noncondensing    34   nicom   NI9514 Operating Instructions and specifications    Maximum altitude    2 000 m  Pollution Degree  IEC 60664            2    Environmental Management    NI is committed to designing and manufacturing products in an  environmentally responsible manner  NI recognizes that  eliminating certain hazardous substances from our products is  beneficial to the environment and to NI customers     For additional environmental information  refer to the Minimize  Our Environmental Impact web page at ni  com environment   This page contains the environmental regulations and directives  with which NI complies  as well as other environmental  information not included in this document     Waste Electrical and Electronic Equipment  WEEE     Y EU Customers At the end of the product life cycle   a
13. l Connections                                                                                                                                  Figure 4 shows the NI 9514 block diagram   Figure 4  NI 9514 Block Diagram  Phase A   0        DAC Dive  Receiver Command  Phase B   0         _ Circuitry 7  nde  0  aise  Position Microprocessor  Capture  PID Loop     rive  Enable  Home 6        Output  Forward      Circuitry Vsup      Reverse          Input    Circuitry    I      com      Digital Input  0 1  4 T  e  5V Reg F     5V OUT                      ha Note This document provides a brief overview of the  module signal connections  Refer to the M 951x User  Manual  which you can download from ni  com   manuals  for more information about signal connections     12   nicom   NI 9514 Operating Instructions and specifications    Drive Command Output   The NI 9514 module provides a  10 V analog Drive Command  output  Use the Drive Command COM signal instead of COM as a  reference for the Drive Command Output  This reference signal  helps keep digital noise separate from the analog output        Encoder Signals    The encoder channel consists of a Phase A  a Phase B  and an Index  input  The NI 9514 supports RS 422 differential and single ended  inputs for Phase A  Phase B  and Index signals  and provides a   5 V output for encoder power  National Instruments strongly  recommends you use encoders with differential line driver outputs  for optimized noise immunity and improved accurac
14. ll products must be sent to a WEEE recycling center   For more information about WEEE recycling centers   National Instruments WEEE initiatives  and compliance  with WEEE Directive 2002 96 EC on Waste and  Electronic Equipment  visit ni  com environment   weee     NI 9514 Operating Instructions and specifications      National Instruments   35    EFAA ais Ril BEDE ChE ROHS   RAA National Instruments th Hatta   GS   PE REMEH REA EME  ROHS  KF  National Instruments  F iE  ROHS GWEIR EO WER  ni com environment rohs_china   For information  about China RoHS compliance  go to ni com   environment  rohs_china                                 Worldwide Support and Services       The National Instruments website is your complete resource for  technical support  At ni com support you have access to  everything from troubleshooting and application development  self help resources to email and phone assistance from   NI Application Engineers     A Declaration of Conformity  DoC  is our claim of compliance  with the Council of the European Communities using the  manufacturer   s declaration of conformity  This system affords the  user protection for electromagnetic compatibility  EMC  and  product safety  You can obtain the DoC for your product by visiting  ni com certification  If your product supports calibration     36   nicom   NI 9514 Operating Instructions and specifications    you can obtain the calibration certificate for your product at  ni com calibration     National Instrument
15. n example of wiring the input signals to a sinking  output device     Figure 8  Limit or Digital Input Circuit Configured for Sourcing       NPN  Sinking                                         Output Device NI 9514      Ve a   i   i i  i i   i         Pae      i   Current oe t i        Limiting  OC    gta Input     i 1 ji it 1      Limit  Home    Circu    Out   or Digital Input 4  i i i i     TAL iv      Reference i   i o      COM      16   nicom   NI9514 Operating Instructions and specifications    Drive Enable   The NI 9514 Drive Enable signal is software configurable for  sinking or sourcing output type and the active state is software  configurable for on or off     Caution Do not connect the Drive Enable output to a   5 V input circuit when the Drive Enable output is  configured for sourcing     Figure 9 shows an example of wiring the output signals to a sinking  input device     Figure 9  Drive Enable Output Circuit Configured for Sourcing       NPN  Sinking                                            NI 9514 Input Device  Ueno eue Cahir Se ak loses A ear  i NI 9514 Vsup   V     i A  i i   i    Drive Enable Is  i   i  i  gt   le    Drive Enable In    i Configured hd      i For Sourcing   1   Sinking         i Circuit   i    COM   i i  i e i    i      i i  Reference      NI 9514 Operating Instructions and specifications      National Instruments   17    Figure 10 shows an example of wiring the output signals to a  sourcing input device     Figure 10  Drive Enable Output 
16. odule     A Caution To meet radio frequency emission  requirements for marine applications  use shielded cables  and install the system in a metal enclosure  Suppression  ferrites must be installed on power supply inputs near  power entries to modules and controllers  Power supply  and module cables must be separated on opposite sides of  the enclosure and must enter and exit through opposing  enclosure walls     NI 9514 Operating Instructions and specifications      National Instruments   3    Connecting the NI 9514       The NI 9514 servo drive interface module is part of a family of  C Series motion modules  The module provides servo drive  interface signals for a single axis  a full set of motion I O including  inputs for a home switch and limit switches  incremental encoder  inputs for position feedback  and 0 to 30 V digital input lines  The  NI 9514 also includes a processor to run the spline interpolation  engine and PID control loop  Working together they produce  smoother motion resulting in precise servo motion control     System Connection    The NI 9514 has two connectors  a 15 pin DSUB drive interface  connector and a 20 pin MDR feedback connector  The 15 pin  DSUB includes command signals for interfacing with servo  amplifiers or drives  a 0 to 30 V general purpose digital input line   and a 19 to 30 V input for power connection  Refer to Table 1 for  the DSUB connector pin assignments     DE Note The remainder of this document does not  distinguish between dri
17. onsumption and thermal dissipation     NI 9514 Operating Instructions and specifications      National Instruments   21    Specifications       The following specifications are typical for the range  40 to 70   C  unless otherwise noted  All voltages are relative to COM unless  otherwise noted     Servo Performance    Module modes of operation        Position loop and torque loop       Control loop rate  20 kHz max  position loop   Servo control loop modes              0 0    PID  PIVff  and Dual Loop    Motion Command Signals  Servo command analog outputs       Voltage range     10 V  relative to  Drive Command COM  Resolution    16 bits  0 000305 V LSB    monotonic  Max output current     2 mA          1 When using a torque loop  the control loop rate depends on the processor speed and  communication bus bandwidth  Refer to the NI SoftMotion Module book of the  LabVIEW Help for more information     22   nicom   NI 9514 Operating Instructions and specifications    Drive enable output          Outputty pe    rennes  Software selectable   sinking or sourcing   Voltage range      0 to 30 V   Voup INPUT    19 to 30 V   Continuous output current  15    on each channel     100 mA max   Output impedance  R                   0 3 Q max    Output voltage  Vo  sourcing       Vay    oRo   Output voltage  Vo  sinking         IoRo    Min output pulse width                100 us  Active state    Software selectable   on or off  Motion I O  Encoder 0 Phase A B and Index inputs  P  ri ees RS
18. pulses        Lit    The power supply  V4  is connected but the module is  not receiving encoder pulses   Limit Active    The Limit Active LED  yellow  has two states to display the status  of the limits and home input       Off The power supply  V sup  is not connected  or both the  limits and home input are not active       Lit The power supply  Vi  is connected and the forward  limit  reverse limit  or home input is active     20   nicom   NI 9514 Operating Instructions and specifications    Axis Fault    The Axis Fault LED  red  has two states to indicate the presence of  a fault in the system  Refer to the MI SoftMotion Module book of   the LabVIEW Help for a list of module faults and troubleshooting  information       Off   No module faults        Lit   One or more module faults     Sleep Mode       This module supports a low power sleep mode  Support for sleep  mode at the system level depends on the chassis that the module is  plugged into  Refer to the chassis manual for information about  support for sleep mode  If the chassis supports sleep mode  refer to  the software help for information about enabling sleep mode  Visit  ni com info and enter cseriesdoc for information about   C Series documentation     Typically  when a system is in sleep mode  you cannot  communicate with the modules  In sleep mode  the system  consumes minimal power and may dissipate less heat than it does  in normal mode  Refer to the Specifications section for more  information about power c
19. s corporate headquarters is located at 11500  North Mopac Expressway  Austin  Texas  78759 3504  National  Instruments also has offices located around the world  For  telephone support in the United States  create your service request  atni com support or dial 512 795 8248  For telephone support  outside the United States  visit the Worldwide Offices section of  ni com niglobal to access the branch office websites  which  provide up to date contact information  support phone numbers   email addresses  and current events     NI 9514 Operating Instructions and specifications      National Instruments   37    Refer to the WI Trademarks and Logo Guidelines at ni  com trademarks for more information on National  Instruments trademarks  Other product and company names mentioned herein are trademarks or trade names of  their respective companies  For patents covering National Instruments products technology  refer to the appropriate  location  Help  Patents in your software  the patents   txt file on your media  or the National Instruments Patent  Notice at ni   com patents  You can find information about end user license agreements  EULAs  and  third party legal notices in the readme file for your NI product  Refer to the Export Compliance Information at  ni com legal export compliance for the National Instruments global trade compliance policy and  how to obtain relevant HTS codes  ECCNs  and other import export data        2009 2013 National Instruments  All rights reserved     3
20. ves and amplifiers  All  references to drives also apply to amplifiers     4   nicom   NI9514 Operating Instructions and specifications    The 20 pin MDR connector includes incremental encoder  feedback inputs  a  5 V output for encoder power  home  limit   and position compare inputs  an output for position compare  an  additional 19 to 30 V input for power connection  and an additional  0 to 30 V general purpose digital input line  Refer to Figure 2 for  the MDR connector pin assignments             Note The NI 9514 requires an external power supply     You can connect the external power supply to the Vas   input provided on the DSUB or MDR connector  Do not  connect more than one external power supply to the  module     NI 9514 Connection Options    National Instruments offers several options for connecting the   NI 9514 to servo drives  You can use the NI 9514 16 to AKD cable  to connect the NI 9514 to the AKD analog servo drive and AKM  series servo motors from NI  To connect to third party servo drives  use the NI 951x Cable and Terminal Block Bundle  Refer to  Figure 3 for the 37 pin terminal block pin assignments  Refer to the  NI 951x User Manual  which you can download from ni  com   manuals  for information about additional connection accessories  and cabling recommendations     NI 9514 Operating Instructions and specifications      National Instruments   5    Tip NI offers AKD analog servo drives and matched   Q servo motors  Refer to Getting Started with NI 9514 
21. y in all  applications  Figures 5 and 6 show simplified schematic diagrams  of the encoder input circuit connected to differential and  single ended encoder outputs     NI 9514 Operating Instructions and specifications      National Instruments   13    Figure 5  Differential Encoder Input Circuit             Encoder NI 9514    i i i       Phase      i      5V           Receiver  i i        Phase      i i   i  i i i        COM i       Phase               5V  Receiver       No  Connection       14   nicom   NI 9514 Operating Instructions and specifications    Limit and Digital Input Signals    You can configure the Forward Limit  Reverse Limit  and   Digital Input  lt 1  2 gt  signals in software for sinking or sourcing  output devices and set the active state of the inputs in software to  on or off  To use the Drive Fault signal referenced in Figure 1  you  can map an available digital input in software  Figure 7 shows an  example of wiring the input signals to a sourcing output device     Figure 7  Limit or Digital Input Circuit Configured for Sinking       PNP  Sourcing   Output Device NI 9514                                             1 z 1  1 1 I 1  I 1 I 1  1 1 1 I  1 1 1 1  1 1 I    i i i        Limit Home  i I   1 igi I 1    Out  or Digital Input 4  1 i   Current   Limit  Home           Limiting or Digital Input    i   1 Circuit    i V            Reference  4   COM      NI 9514 Operating Instructions and specifications      National Instruments   15    Figure 8 shows a
    