        PLA 2.0 User Manuals - PLA 3.0 – Software for Biostatistical Analysis
         Contents
1.                                                                                                           143  Audit Trail                                                                                                                          145    Table Of Contents    v    Change your Password                                                                                                       146  Context Menu                                                                                                                    147  Create Object                                                                                                                     149  Database Manager                                                                                                             151  Database Manager Connect                                                                                                 153  File Menu                                                                                                                          155  Help Menu                                                                                                                         157  License Management                                                                                                          158  Login                                                                                                                                 160  Options                         
2.                                                                                                     162  Product Information                                                                                                           167  Register Your Copy of PLA                                                                                                  168  Session  amp  Lock Management                                                                                               171  System Menu                                                                                                                     173  System Locked                                                                                                                   175  Validation Menu                                                                                                                 176  Window Menu                                                                                                                    177  PLA 2 0 vs  PLA 1 2                                                                                                                   179  No Interaction of PLA 1 2 and PLA 2 0                                                                                     179  Data Migration                                                                                                                      179  PLA 1 2   PLA 2 0 Licensing                                              
3.                                                                             123  IT Administration Guide                                                                                                             125  Welcome to the PLA IT Administration Guide                                                                           125  Description of PLA for IT Professionals                                                                                    126  PLA Setup Basics                                                                                                                   127  PLA is Microsoft Windows Compliant                                                                                    127  Customizable Directories of PLA                                                                                           127  Other Directories of Interest                                                                                                127  Hardlock Installation                                                                                                           128  Security Basics                                                                                                                      129  User Account Security                                                                                                         129  Data Integrity                                                                                                    
4.                                                                        21  Connect to PLA                                                                                                                        22  Log in to PLA                                                                                                                       22  Screen Layout                                                                                                                      23  The Objects of PLA                                                                                                                  24  Managing Objects                                                                                                                 25  Editing Objects                                                                                                                     35  Inheritance  Templates and the Apply Function                                                                       40  Import and Export                                                                                                                48  Object Properties                                                                                                                     68  Introduction                                                                                                                         68  General Properties                                                                 
5.                                                                       114  Cryptographically Secured Reference Data                                                                            114  Recommendation for your IQ OQ Procedures                                                                       114  Installation Qualification                                                                                                         115  The Installation Qualification Process                                                                                   115  Performing the Installation Qualification                                                                               116  Operational Qualification                                                                                                        118  The Operational Qualification Process                                                                                  118  Performing the Operational Qualification                                                                              119  Performance Qualification                                                                                                       120  The Performance Qualification Process                                                                                 120  Preparing the Performance Qualification                                                                               121  Performing the Performance Qualification 
6.                                                       179  Stegmann Systems                                                                                                                   181  System Requirements                                                                                                               183  Copyright                                                                                                                                 185  Licensing Agreement                                                                                                                 187     1     Version 0 90  2006 08 16     Welcome to PLA 2 0    PLA 2 0 is a software package for the development and analysis of Parallel Line Assays and Parallel   Logistics Assays  The following keywords describe the options of PLA to give a short summary     Statistical Features         Parallel Line Assay       Four Response Transformations for Parallel Line Assays       Configuration Optimization for Parallel Line Assays       Parallel Logistics Assays based on 4  and 5 Parameter Fit       Four Outlier Detection Methods  Optional        Dixon Test for Data Outliers       Grubb s Test       Standard Deviation Test        Externally  Studentized Residuals       Manual Removal as Technical Outliers       ANOVA Models       Separate ANOVAs  PLA 1 2 compatible        ANOVA based on Pure Error Separation  European Pharmacopoeia        ANOVA based on Residual Error       Test of Par
7.                                                      5  E Mail                                                                                                                                      5  Phone                                                                                                                                      5  Fax                                                                                                                                          5  Getting Started                                                                                                                            7  Parallel Line and Parallel Logistics Assays                                                                                   7  Installation of PLA 2 0                                                                                                               8  CD ROM Version of PLA 2 0                                                                                                    8  Download Version of PLA 2 0                                                                                                  8  Attach the Software Licensing Module  Hardlock                                                                        12  Basic Database Management                                                                                                    13  File Based Database                                                                                 
8.                                                69  Dose Properties                                                                                                                    71  Data Properties                                                                                                                    73  Analysis Properties                                                                                                               74  Configuration Properties                                                                                                        77  Documentation Properties                                                                                                     79  GxP Settings                                                                                                                        81  Analyze Assays                                                                                                                        83  Introduction to Assay Analysis with PLA                                                                                 83  Explore your Assay                                                                                                               84  Combination of Assay Results                                                                                                87  Calculate  amp  Report                                                                                                       
9.                             13  Database Server Based Databases                                                                                         14  Basic Concepts of PLA 2 0                                                                                                        15  Database Storage Concepts                                                                                                   15  Object Types and Hierarchy                                                                                                  15  Inheritance of Object Properties                                                                                            16  Basics of PLA 2 0 Mathematical Features                                                                                   17  Doses and Potencies                                                                                                             17  Model  Response Transformation and Outlier Detection                                                           18  Analysis of Variance  ANOVA                                                                                                 19  Configuration Optimization                                                                                                    20  User Guide                                                                                                                                 21  Introduction to Assay Analysis with PLA              
10.                  101  Create The Standard Object                                                                                                103  Create The Preparation Object                                                                                             104  A First Look                                                                                                                           105  Optimizing the Configuration                                                                                                  107  Switching the Regression Model to 5 Parameter Logistics                                                          109  What About Equivalence Testing                                                                                             110  Final Computation and Reporting                                                                                            111  Validation Guide                                                                                                                       113  Welcome to the PLA 2 0 Validation Package                                                                             113  What is included in the package                                                                                          113  Principles of Validation                                                                                                           114  Validation of Each System                             
11.                 129  Database Security                                                                                                              129  Database Guide                                                                                                                     130  PLA Databases                                                                                                                   130  PLA Database Maintenance                                                                                                 131  Advanced Database Administration                                                                                      135  PLA License Management                                                                                                       136  Retail Mode                                                                                                                       136  Reference                                                                                                                                139  User Interface Reference                                                                                                        139  Account Management                                                                                                         139  Action Menu                                                                                                                      142  Apply                      
12.         89    PLA 2 0 User Manuals    iv    Advanced Topics                                                                                                                     91  Electronic Signatures                                                                                                            91  Secure Transfer of Data and Objects                                                                                      93  Audit Trail                                                                                                                            94  My First Assay with PLA                                                                                                               97  My First Assay with PLA                                                                                                           97  The Exemplary Data                                                                                                                98  Hierarchy of Objects                                                                                                              100  Data Input                                                                                                                            101  Create the Project                                                                                                              101  Create The Assay                                                                                              
13.    Recommended System        Intel Pentium IV  or compatible  Processor with 2Ghz       1 Gigabyte of System Memory  RAM        500 Megabytes of free Hard disk space       Microsoft Windows XP         185    Copyright    PLA 2 0     2006 Stegmann Systems  Rodgau  Germany  All rights reserved   The Stegmann Systems products referred to in this document are also copyrighted  and all rights are  reserved by Stegmann Systems and or its licensors  if any  This manual may not  in whole or in part   be copied  translated  or reduced to any electronic medium or machine readable form without prior  consent  in writing  from Stegmann Systems   The information in this manual is subject to change without notice  and Stegmann Systems assumes  no responsibility for any errors that may appear in this document  The references in this manual to  specific platforms supported are subject to change   Java and all Java based marks are trademarks or registered trademarks of Sun Microsystems  Inc  in  the U S  and other countries   Any other trademarks or service marks contained herein are the property of their respective owners   PLA 2 0 includes software developed by the Apache Software Foundation  http   www apache org     Copyright 1999 2006 The Apache Software Foundation  All rights reserved  The names  Xalan    FOP     Avalon Framework    Batik    Xerces    Commons logging  and  Apache Software Foundation  must  not be used to endorse or promote products derived from this software without pri
14.    This button will be enabled if you ve entered the vendor response in the green text edit field  Pressing  the button will check the entered code and activate PLA or a PLA feature     Explanation    A short text explaining how to use the License Manager     Product Information    Open the Product Information Dialog   See also  Product Information    Close    Close this dialog     PLA 2 0 User Manuals    160    Login    The Login dialog allows you to login to a database  It provides a list of databases to choose from and  means to create new database connections  Once you have selected the database  the dialog shows  the registered users of this database  Select the desired user and type in your password  Then press  the  Login  button to proceed      Database    This is a list of your database connection profiles  Select the desired database connection profile  PLA  tries to establish the database connection and shows an updated user id list  If for any reason PLA  could not open the database  contact your IT administrator     Manage       Opens the Database Manager which allows you to manager your database connection profiles     User ID    A list of users of the currently selected database  Select your user account by clicking on your user  name     Password    Enter your password here     Login    Executes the login     Reference    161    Exit    Quit PLA     Status    Shows status information about your PLA installation   E g   The remaining time of your PLA Trial     
15.   Aging       Complexity       Black Lists       Inactivity Lock       Audit Trail       Documents signed digitally using the internal PKI for storage integrity     3    Overview of the Manuals    There are several guides available to you  Stegmann Systems has structured the help system  according to your roles you might have concerning PLA   First  you might have a look in the Getting Started section  A few pages tell you about the basic  installation and principles of PLA     PLA User    A PLA User uses PLA to define and calculate his assays based on the settings a PLA administrator  defined for the database in use  The most relevant sources of information are      PLA 2 0 User Guide  Learn the principles of PLA and its efficient use      PLA 2 0 My First Assay with PLA  Follow a systematic guide to define and analyze a simple assay      PLA 2 0 Reference  Find reference information for mathematical and technical options of PLA      PLA 2 0 Tutorial Videos  Some Flash Videos for common tasks within PLA   Online Help only     PLA Administrator    The PLA Administrator is responsible for setting up an already installed PLA for a workgroup  He  defines user accounts and the global settings for the assay analysis  PLA Administrator is a role inside  PLA      PLA 2 0 Administration Guide  Find information concerning the PLA Administration      PLA 2 0 Validation Guide  Find out how to validate PLA using the PLA Validation Package    IT Administration    The IT administration is 
16.   Check  carefully      Figure  Screen layout of the Dose Properties    PLA 2 0 User Manuals    72     User Guide    73    Data Properties    Data Properties define the dimension and data values of a standard or preparation   Property  Description    Dimension and Dilution Scale  Number of  Treatments  The number of treatments  dilution steps  in this object     Number of  Replicates  The number of replicates in the object    Dilution Scale   1 in 2 series  or  direct input     Data Values  Data  Depending on the dilution scale property you edit the dose and  response values    Figure  Screen Layout of the Data Properties    PLA 2 0 User Manuals    74    Analysis Properties    The analysis properties describe details of the potency calculation   Note  The effective values of the properties marked with a star     are those of the corresponding  preparation object  The effective values marked with a double star      are taken from the standard  or preparation when the Separate ANOVAs are chosen  they are from the preparation in the other  cases   Property  Description    Model  Model    Select the Regression Model for the analysis        Parallel Line Model  Linear Response       Parallel Line Model  Logarithmic Response Transformation       Parallel Line Model  Square Root Response Transformation       Parallel Line Model  Square Response Transformation       4 Parameter Logistic Curve       5 Parameter Logistic Curve    Invert Potency  Ratio    Check to invert the potency rat
17.   Every object can be signed electronically with  one exception  assay object signatures are always recursive on the child objects of the assays  An  object can have any number of signatures     Sign An Object    To sign an object  simply open it on the general page  and click the Sign button  The following dialog  appears     If you want to apply your signature to the child objects too  at the project level   check this    element  Type in your password and click Sign  Once you have clicked  Sign  the requested signatures  are applied  The application of a signature is logged in the audit trail   Note 1  A signature makes an object read only  No further changes can be applied to the object as  long as the signature is in place   Note 2  Default reasons can be defined in the system options dialog     Remove A Signature    The PLA Administrator defines  wether a signature can be removed by everyone  by the signer himself  or by administrators only  A signature removal is logged in the audit trail   To remove a signature open the object go to the electronic signatures section and click Remove  The  Remove Electronic Signature dialog appears     PLA 2 0 User Manuals    92    You may select to remove all signatures of the object and to recursively remove signatures from the  child objects  To start the removal type in your password and press Remove     User Guide    93    Secure Transfer of Data and Objects    PLA enables you to securely transfer assay data and templates between 
18.   PLA 2 0 User Manuals     iii    Table Of Contents    Welcome to PLA 2 0                                                                                                                     1  Statistical Features                                                                                                                1  Data Management and Reports                                                                                              1  GxP Features                                                                                                                        1  21 CFR Part 11                                                                                                                      2  Overview of the Manuals                                                                                                              3  PLA User                                                                                                                                  3  PLA Administrator                                                                                                                     3  IT Administration                                                                                                                      3  Getting Support                                                                                                                           5  Websites                                                                             
19.   The chapter describes all the properties of the objects        Analyzing Assays  How are assays analyzed with PLA  How do I create reports        Advanced Topics  Information concerning the Audit Trail and the secure transfer of data  objects and templates     PLA 2 0 User Manuals    22    Connect to PLA    Log in to PLA    PLA has its own User Management Infrastructure  You are required to log in to a database to work  with PLA  After you have started PLA  the Login dialog appears  This dialog allows you to log in to the  selected database  to select other databases and to start the database manager  You may also start  the product information and license detail dialogs     First of all select the required database if it is not already selected   Once you have connected the database  the section User ID contains the list of defined users in that  database  In the figure there is only a PLA Administrator defined  Select your desired User ID and  type in your password  By clicking Login  or pressing the enter key  you are logged in  If the  password was wrong  the user id was deactivated  the users password expired or if administrative  database access has been activated there may be further messages   On the right hand side of the dialog registration information  product information and license  informations are displayed  You may edit the registration information by selecting the hyperlink  Click  to Edit  on the upper right of the figure  The product information and licen
20.   This database type should not be shared with more than 3 or 4 concurrent users        Size restriction  The maximum size of the database is limited to 2 Gigabytes        It should be compacted using the PLA Database Manager regularly   Advantages        This database type can be created without deeper knowledge of database servers or  involvement of your IT department     PLA 2 0 User Manuals    14         This database type is file based  You only need write access to a network share to  create and connect to this database type  No administrative privileges are required        Since the database contains of only one file it is easy to backup     Database Server Based Databases    These databases require an installed Database Server  Currently the following database management  systems are supported        Microsoft SQL Server 2000 Desktop Engine  MSDE        Microsoft SQL Server 2005 Express Edition       Microsoft SQL Server 2000 or higher  The database administrator has to create an empty database on the database server  Once you have  defined a connection to this database using the PLA Database Manager PLA automatically creates the  required tables in this database   There are some basic things to know        The Database Server user account PLA used to connect to the database needs to be able to  modify the database using standard SQL DDL and DML statements  If your IT department  does not accept this  they ll have to create the tables using a SQL Script available with
21.   contact  support bioassay de     Validation Guide    119    Performing the Operational Qualification    From the Validation Menu select Operational Qualification  OQ   The following dialog appears     Press Start to start the OQ Process  This process can take up to 60 minutes  The certificate error  report is created in the standard output directory  The certificate can be launched by clicking on the  hyperlink  that is available after the process finished   Note  If you want to check the OQ with its documentation you can toggle the cleanup switch     If you deactivated it  you can verify all the objects and calculation results after the OQ process has  been finished     PLA 2 0 User Manuals    120    Performance Qualification    The Performance Qualification Process    The Performance Qualification  PQ  is intended to test customer data with the mathematics of the PLA  system  In PLA this process is divided into two steps   1  Prepare your Performance Qualification Data  2  Execute the Performance Qualification on any target system  Note  When new PLA Version get available  it might be necessary to repeat both steps     How does it work     The Performance Qualification is prepared using the preparation wizard  Using this wizard you select  your well known PQ project inside PLA  The wizard calculates the comparison data and generates a  PQ file as well as a Complete Statistics Report  The PQ file is secured from manipulation by the  systems internal PKI  Once you have thor
22.  2 0 User Manuals    50     Import Standard Path    Start The Import Wizard    First of all  start the import wizard by selecting Import from the file menu  the navigators context  menu or from the toolbar  The Import Wizard comes up      Select Import Format    Now select the desired import format  The PLA external file types are always displayed  The other  displayed file types depend on your installed PLA Import Modules   In this sample we now select a PLA 2 x Enhanced Format    PEF  file  After you have selected the file  type  press  Select File  or simply double click the desired file type   A standard dialog of the operating system for opening a file appears     User Guide    51    Select a file and press Open   In the sample the file Project PEF is chosen    Note  The Import Default Path can be set in the Options dialog     Analysis of the Import File    Once you selected the file  it is immediately analyzed by PLA  The results of the analysis are displayed  in the Import Wizard      PLA 2 0 User Manuals    52    If the analysis is successful the Next gt  button gets activated  Our sample shows 40 valid objects   If the selected file format requires a PLA Import Module to be executed  it will start automatically  You  will see an result code of the external Import Module   Press Next gt  to view the objects to be imported     The Object Import Tree    The PLA Import Wizard now displays the Import Tree     On this page you have several options        Include and Exclud
23.  PLA   details are found in the IT Administration Guide        The integrity of PLA s data is not endangered by the knowledge of this account  because all  relevant data is protected by the use of cryptography  However  this account should be kept  secret  because it allows corrupting the database  PLA is able to detect corruptions of the  database and it prevents corrupted objects from being used   Further details for Database Server based databases are found in the IT Administration Guide     Getting Started    15    Basic Concepts of PLA 2 0    There are a few basic concepts you should understand for efficient use of PLA        Database Storage Concepts       Object types and hierarchy       Inheritance of object properties    Database Storage Concepts         All Assay Data and Properties are stored in the selected database   There is no need to work with individual files while working with assays  The advantage of  this approach is the easy accessibility of the data even across networks  All data  properties   audit trail information and security information is held at a single place  The navigator allows  you to navigate between the projects and assays of your database        The selected database completely defines the security environment  All account definitions or other security relevant data are stored in the database  By this way   you are able to define high and low security projects and databases     Object Types and Hierarchy    PLA makes use of five different 
24.  Unused Database Connection can be removed by the Database Management Dialog  This does not  delete the database either from the file system nor a SQL Server database     Compact Database    File based Databases can grow up to 2 GB during work  They might be internally fragmented while  time passes  From time to time you should compact the database  This defragments the database  and removes unused file space from the database   In the Database Management select the database to be compacted and then press Compact  Database  After the compaction succeeded you receive a message on the saved space     Note  you need exclusive access to the database to compact it     IT Administration Guide    135    Advanced Database Administration    Distribution of Connection Profiles Using Registry Settings    In management environments you can distribute connection profiles of PLA Server setting to the end   user systems by registry files  by your software distribution system or by active directory distribution   Create a database connection to the required database using PLA 2 0  The database connection string  can be found in the registry under the key   HKEY_LOCAL_MACHINE Software Stegmann Systems PLA 2 0 Connections  Under this key you find each connection as a REG_SZ variable  The name of the variable defines the  connection name  This can be freely edited  The value is a cryptographically secured connection  information to the database  It has to be copied as is   The simplest way to c
25.  calculations  The report is augmented with three  graphs per assay   Excel Report  requires Microsoft Excel 2003 or higher   The Excel Report contains the data and the potency results for further processing   Graphics Report  requires Adobe Acrobat Reader   This report contains large graphics of the regression results   Short Report  requires Adobe Acrobat Reader   Short Report without Graphics  requires Adobe Acrobat Reader   The short report contains the data  the results of the hypothesis tests and the potency calculation on  a single page per assay     Technical Remarks on Preview and Print    1  Print and Preview make use of the corresponding application  E g  if you create a Adobe PDF  report  the Acrobat Reader or an alternative viewer for PDF file has to be available and the file  type of PDF has to be registered in the operating system   2  If you want to test the availability of the application  save the report to any location  Then  start the Windows Explorer and try to open the file by double clicking  If the report is  displayed  PLA is able to display the report  If it is not displayed  PLA will not be able to open  the report  The print method can be tested by selecting the Print command of the Windows  Explorers Context menu of the file  open with a right click   Then select print  If the report is  printed  PLA will be able to print to     User Guide    91    Advanced Topics    Electronic Signatures    PLA accepts electronic signatures for the objects of PLA
26.  dialog is checked   PLA is able to combine results of any preparations within a project     Definition of Combination Groups with the Assay Editor    Add the preparation to an assay by creating new combination groups  This methods is available for  projects and assays to  allowing you to use inheritance      Defining Combination Groups with the Combination Group Editor    The Combination Group Editor supports the efficient definition of the combination groups of a project     PLA 2 0 User Manuals    88    The editor has two tree views   The left tree shows the defined combination groups within the selected project  You can create  additional groups  rename groups and delete groups using the appropriate command buttons   Preparations can be removed  If you want to add a preparation  select the group which should get the  preparation  than switch to the right tree view and use the  Add to Group  button   Below the trees you can see a few details on the preparations  If the preparations have been  calculated earlier  cached calculation results are shown below the tree views   When finished press Save  to save the groups and close the dialog     User Guide    89    Calculate  amp  Report    To obtain final calculation results select the assay or project in question and then select the Calculate  method from the file menu  the navigator context menu or from the toolbar  The Calculate Assays and  Create Reports     By double clicking a report template or by selecting one of the fo
27.  integrity of the Performance Qualification data PLA makes use of a special pair of  cryptographic keys only used for PQ data  This opens a security shell for this type of data  Only PLA  itself is able to create PQ data sets  There is no way to compromise these data sets     Recommendation for your IQ OQ Procedures    Depending on the status of your internal IQ OQ procedures we would like to suggest to base your  IQ OQ procedures for PLA on the automated procedures of PLA and the certificates they provide  This  can drastically reduce the effort to qualify new releases of PLA  Stegmann Systems will verify its IQ  and OQ data sets with every  sub   release of PLA  Due to the cryptographically secured files  PLA is  able to provide you with required certificates  Stegmann Systems guarantees the availability of this  approach for the complete PLA 2 x product line  Even Import Modules and Report Templates are  delivered with the required IQ reference data  so their correct installation we be confirmed with the  certificates too     Validation Guide    115    Installation Qualification    The Installation Qualification Process    Goals of the Installation Qualification    During the installation of a software product like PLA software components are installed at several  locations of the computer system  The components installed divide into the following groups        The Main Program and its files  These are typically installed in the Program Files directory of  windows  Files i
28.  parallel line method  This robust method allows you the calculation of the potency with a  minimum effort  The asymptotes of the sigmoid dose response relationship are neglected        Parallel Logistics Assays  4PL  5PL   The four and five parameter function according to Rodbard describe the full dose response  relationship  You need at least four or five parameter to calculate these methods   Both methods require logarithmic transformations of the dose values  There is no mathematical  implication which base of the logarithm to use  PLA uses to logarithm on the base of 2  This approach  has two advantages        The mathematics of Parallel Line Assays has been best described by D J  Finney who makes  use of the base 2        If you use twofold dilution series  the transformed numbers are integer values   PLA calculates the potencies for each preparation of an assay separately     Transformations    PLA allows four different transformations for parallel line assays  They can be used to reduce an  inhomogeneous variance distribution  Available models are    Getting Started    19         linear transformation       logarithmic transformation       square root transformation       square transformation    Outlier Detection    PLA has four optional outlier tests available  An outlier test removes response values from analysis  that match a specified statistical criterion   Three treatment based outlier tests are available  when you have three or more replicates        Dixon Tes
29.  used as password  separated by  semicolon  This list applies to all accounts and prevents the usage of simple  passwords like  assay           Electronic Signatures    1    Signatures may be removed by  1  Defines who is allowed to remove electronic signatures from objects   2     Possible Values 1   admins only  2   the signer  3   everyone  Default value  2   the signer  2   3    List of pre defined comments for electronic signatures  1  A semicolon separated list of pre defined comments for electronic signatures          Navigator Defaults    1    Autorefresh Interval  1  Defines the number of seconds to elapse until a navigator refresh occurs   2     Possible Values 5   3 600  Default value  30  2   3    Autorefresh Navigator  1  Defines whether the navigator is refreshed automatically  Only useful in multi  user environments   2     Possible Values No  Yes  Default value  No  3     Reference    167     Product Information    This dialog shows detailed information about your PLA Installation      Postal Address    The vendors postal address     Phone   Fax    The vendors telephone and fax number     Version    The  detailed  version number of your PLA installation     Serial Number    Your PLA serial number     www bioassay de    Open the products Website in your default web browser     support bioassay de    Opens your default mail client allowing you to write an e mail to the support     OK    Close this dialog     PLA 2 0 User Manuals    168    Register Your Copy of P
30. 0 223  0 24    1 128  0 119  0 152  0 161    1 256  0 102  0 137  0 125    1 512  0 115  0 139  0 123    1 1024  0 117  0 137  0 124    1 2048  0 086  0 128  0 106    The data of the preparation is as follows   Dose Response  Replicate 1  Replicate 2  Replicate 3    1 1  0 732  0 717  0 704    1 2  0 731  0 674  0 715    1 4  0 618  0 663  0 638    1 8  0 618  0 524  0 56    1 16  0 348  0 354  0 381    1 32  0 224  0 22  0 238    1 64  0 141  0 15  0 137    1 128  0 101  0 135  0 127    1 256  0 111  0 133  0 127    1 512  0 119  0 128  0 11    1 1024  0 118  0 12  0 136    1 2048  0 131  0 128  0 129    This is a graphics of our exemplary data     My First Assay with PLA    99    The assay has a strong lower asymptote  a highly significant area and it seems to close in an upper  asymptote  This is not to easy to be analyzed   We would prefer to analyze the data as a parallel line assay  but we will have a look at the 5   parameter logistics too     PLA 2 0 User Manuals    100    Hierarchy of Objects    For this assay to be analyzed with PLA we need the following structure of objects   A parent project  which serves as a container for any number of assays   Sample Project   An assay object  representing the full assay  Assay   A standard for the settings of the standard  Standard   A preparation for the data  whose potency is of interest  Preparation   In the user manual it is stated that the inheritance is a major tool in PLA to setup assays as easy as  possible  In this tu
31. Administrator adds a user to the system    USRMGMT_DELETEUSER  An administrator removes an user from the system    USRMGMT_MODIFYUSER  An administrator modifies user details    OBJECT_SAVED  An object has been saved     OBJECT_SIGN  An object has been signed electronically    OBJECT_REMOVESIGNATURE  An object signature has been removed    OBJECT_INITIAL  A new object is created    OBJECT_COPY  An object is copied    OBJECT_MOVE  An object is moved    OBJECT_DELETE  An object is deleted    DB_ADMINACCESS_ON  Database administrative access is requested    DB_ADMINACCESS_OFF  Database administrative access is revoked    DB_COMPACT  Database has been compacted    DB_CHECK_START  A database check has been started    DB_CHECK_STOP  A database check stopped    DB_CHECK_CORRECTION  A database check corrected a problem    DB_ADD_SESSION  A session is added    DB_DELETE_SESSION  A session is removed    DB_KILL_LOCK  A lock has been killed    DB_MIGRATE  The database has been migrated to a new scheme    IQ_START  The IQ starts    IQ_RESULT  The IQ result is logged    IQ_FINISHED  The IQ stops    OQ_START  The OQ starts    OQ_RESULT  The OQ result is logged    OQ_FINISHED  The OQ stops    PQ_START  A PQ starts    PQ_RESULT  The PQ result    PQ_FINISHED  The OQ stops    OPTION_MODIFIED  PLA Options have been modified     User Guide    95    Each entry can have additional detail information  Every relevant modification is fully visible in the  audit trail   The complete audit trail can be 
32. Export    Open the export wizard to export data from PLA into a file   See also  Export    Calculate  amp  Report    Opens the Calculate  amp  Report Dialog which allows you to start the calculation process and create  reports   See also  Calculate  amp  Report    Data Explorer    Opens the Data Explorer  Check Dialog  which shows you a graphical overview of your assay and  preliminary calculation results   See also  Explore your Assay    Reference    149    Create Object    This dialog allows you to create a new object      New Project    This option allows you to create a new Project     New Assay    This option allows you to create a new Assay as member of the currently selected Project     New Standard    This option allows you to create a new Standard as member of the currently selected Assay     New Preparation    This option allows you to create a new Preparation as member of the currently selected Assay     New Control    This option allows you to create a new Control as member of the currently selected Assay     Name    PLA 2 0 User Manuals    150    Enter the name of the object you want to create here     Description    You can optionally enter an description for the object you want to create here     Template    Select a template for the new object     Create    Click this button to create the object     Cancel    Click here to cancel the object creation process     Reference    151    Database Manager    The Database Manager allows you to manage your database conn
33. LA    How to use the registration dialog      Why register     This is a short statement explaining why you should register your copy of PLA     Your Name    Enter your name into this field     Company    Enter the name of your company here     Reference    169    Department    Enter the name of your department here     Address    Enter the address of your company here     City    Enter your city into this field     Zip code    Enter the corresponding zip code here     State   Region    Enter your state or region here     Country    Enter your country here     E mail    Enter your e mail address here     Phone    Enter your or your company s phone number here     Fax    Enter your or your company s fax number here     Keep me informed about PLA and your other bioassay products by email     Enable this option if you want to receive latest information about PLA and other bioassay products of  Stegmann Systems     Privacy statement    A statement explaining to you that your data will not be made available to any third party     Submit  online     Submit your registration online  PLA transmits the data entered above to the Stegmann Systems user  database   Note  This feature requires an internet connection     Generate file    PLA generates a file which you can print   fax or send via Mail     PLA 2 0 User Manuals    170    Never ask again    Closes this dialog  PLA won t ask you again for registration  However  you can open this dialog again  by clicking the  Click to edit  hype
34. PLA 2 0 subdirectory  of the systems programs folder  e g  c  program files Stegmann  Systems PLA 2 0     Application Path  This is a sub directory of the base installation path  This directory contains  the PLA Main Program and libraries     Application Data  Application Data is stored in the All Users and in the Users personal folder in  the Documents and Settings section     Temporary Files  Temporary files are stored in the Temp sub directory of the Application Data  Directory of the user  PLA automatically takes care of this folder     PLA 2 0 User Manuals    128    Hardlock Installation    PLA makes use of the Hardlock Protection by Aladdin Systems  The device drivers for the hardlock  system are installed automatically during the setup process  They appear as Hardlock Drivers in the  Software section of the system configuration  If they are removed they can be reinstalled by hand   Current drivers can be found under www aladdin com     IT Administration Guide    129    Security Basics    User Account Security    Due to regulatory needs PLA has its own user account management  Accounts are stored in the PLA  databases  so security can not be compromised by copying data to another location   The user account system in PLA is role based  PLA distinguishes three roles   Standard Users  Standard Users are allowed to modify objects within the restriction a PLA administrator gave  They are  not allowed to modify security relevant options or to manage user accounts   Administr
35. Register    Click here to register your copy of PLA     Info    Your registration information is shown here     News    Shows latest news about PLA if you are connected to the internet     Product Information    Shows information about the program   See also  Product Information Dialogue    License Management    Opens the License Manager   See also  License Management    Version Information    Detailed information about your PLA version for support purpose     Serial Number    Your PLA Serial Number     PLA 2 0 User Manuals    162     Options    This topic describes the Options dialog and all available settings           Calculation Control Center Options    1    Always calculate combinations of assay results  1  If set to yes the defined groups of combination of assay results are calculated  by default   2     Possible Values No  Yes  Default value  No    3          Application Path Settings    Reference    163    1    Default Export Path  1  Defines the default path to where the export wizard shall export the data to   2    Default Import Path  1  Defines the default path to where the import wizard shall import the data  from   3    Default Output Path  1  Defines the default path to where the created reports or certificates shall be  stored   4    Location of Import Export Modules  1  Defines the path  where PLA Import and Export modules are stored   5    Location of Report Templates  1  Defines the path  where your PLA Report Templates are stored   2          Graphics Opt
36. a  audit trails  user account data and system options   There are two types of databases        File based Database  This type of database can be generated on any local or shared drive  Multiple Users can  connect to this database when it is located on a shared drive  The file based database is a  secured Microsoft JET database   Note  We do not recommend to connect more than 3 concurrent users to this database type        SQL Server Database  PLA allows to use a Microsoft SQL Server Database  MS SQL Server 2000 or higher  MSDE  supported   Depending on your license PLA can accept nearly any number of connection to this type of  database  It should be preferred if you have a SQL Server available     IT Administration Guide    131    PLA Database Maintenance    There are a few Maintenance Tasks for PLA databases     Backup The Databases    PLA Databases have to be backed up on a regular basis  It is the task of the IT Administration to  create backups of file based and SQL Server based databases  Stegmann Systems recommends to  create backups every day     Create A Database    Create A File Based Database    From the Login Dialog select  Manage     on the right of the database selector     The Database Management dialog appears    PLA 2 0 User Manuals    132    Click on the  Create or Connect a Database File  button  A standard file open dialog appears  Select  the directory and type in the name of a new database file   Note  If you select an existing database  nothing is crea
37. account and due to fifth parameter it is able to fit asymmetric dose response relationships   Since we have activated the inheritance property on the analysis page  we open the assay and go to  analysis page  Select 5 parameter logistic curve fit as the model  Then save the assay  Start the Assay  Explorer with Check from the toolbar     We can see the 5 parameter fit for the full with a potency of 0 546  The confidence interval is  calculated as 0 501 to 0 595 which is a little sharper than the confidence limit of the parallel line  assay   Last but not least  we want to take a look at the equivalence test for parallelism     PLA 2 0 User Manuals    110    What About Equivalence Testing    Equivalence Testing has been discussed within the last two or three years  This approach allows to  define an alternative parallelism test  This is of interest especially for very exact assays  where the  parallelism based on the F Test fails very often   Open the analysis page of the editor and select the  Equivalence Test based on Difference of Slopes   as the parallelism test method  Now set the goalpost to  1 5 to 1 5  Save the assay and restart the  Assay Explorer  Switch to the Goalpost Graph     You can see the confidence interval falls entirely between the goalposts  Therefor  the parallelism test  is passed  Close the Assay Explorer   After we have finalized our initial analysis  we now start the final computation     My First Assay with PLA    111    Final Computation and Reporti
38. additional pre dilution factors  The multiplication of these factors with the  stock solution potency defines the concentration of the highest dose   4  Specification of the Dilution Series  The last step is the specification of the dilution series  which should be considered as relative  doses of the dilution steps  If you want to enter absolute doses  don t activate the above  options     Assigned   Assumed Potency    By default  the assigned and assumed potencies of your bulk substance   raw material or stock  solution of your standard and the preparation are considered to be equivalent  If they are equivalent  the application of the analyzed potency factor to the potency of the standard leads to the potency of  the preparation  As a consequence you have to enter potencies only at the standard object   However  especially in Quality Control this approach does not necessarily meet your needs  If your  reference material and your preparation potencies are not identical  PLA calculates relative potencies  of the preparation with respect to the standard and to the assigned potency of the preparation  To get  these values the potencies have to be entered at the standard AND the preparation level     PLA 2 0 User Manuals    18     Model  Response Transformation and Outlier Detection    Parallel Line Method and Parallel Logistics Model    PLA 2 0 supports both        Parallel Line Assays  Typically  you select the linear parts of the dose response curve for the analysis with the 
39. allelism       F Test       Equivalence Test based on Ratio of Slopes       Equivalence Test based on Difference of Slopes       Combination of Assay Results       Raw Bulk Material Potency Calculations       Stock Solution Potency Calculations       Assigned   Assumed Potency Calculations       EC50 Calculation    Data Management and Reports         Database for Storage of Assay Data       Multiple Databases shared over the network  e g  project databases        Secure Storage using an internal PKI Infrastructure       Template Engine for Efficient Input       GxP SOP Support       Secure External Data Transfer using PLA Secure Format  PSF  utilizing the internal PKI of PLA       Export Import       attach  virtually  any external systems using PLA Import and PLA Export Modules       Report Engine based on XML XSL technologies       Adobe Acrobat Portable Document Format  PDF        Microsoft Word 2003 Documents       Microsoft Excel 2003 Documents       any customer specific output       Graphic    GxP Features         Automated Installation Qualification  IQ         Automated Operational Qualification  OQ         Automated Performance Qualification  PQ         Template Engine    PLA 2 0 User Manuals    2         SOP Support  Protect groups of assay properties from manipulation        Role based user administration    requires a license of the PLA Validation Package    21 CFR Part 11         Electronic Signatures       User Login       Fully customizable Password Logic     
40. and  the import export modules directory to central locations  This can be done within the options dialog of  PLA     Customizable Directories of PLA    In the Options dialog or in the registry the following customizable directories of PLA can be set   Default Import  Path  This path is the default path of the import wizard  All open operations of  this wizard initially point to this directory   By default this directory points to a PLA 2 0 sub directory of the users  personal folder     Default Export  Path  This is the default target path of the export wizard   By default this directory points to a PLA 2 0 sub directory of the users  personal folder     Default Output  Path  This is the path where reports and certificates are created by default   By default this directory points to a PLA 2 0 sub directory of the users  personal folder     Import Export  Modules  This is the path PLA uses to search for import and export modules  PLA  might require write permissions in this directory to save Import Definition  Schemes   By default this path points to the  Converter  sub directory of the PLA 2 0  base installation path     Report Templates  In this directory the report templates of PLA are installed   By default this path points to the Report Templates sub directory of the PLA  2 0 base installation path     Other Directories of Interest    Base Installation  Path  This is the target path you select when you install PLA   By default this directory points to a Stegmann Systems 
41. any changes made on the selected object     Close Window    Closes the currently active sheet     Copy    PLA 2 0 User Manuals    156    Copy the selected object   See also  Copying and Moving of Objects    Move    Move the selected object   See also  Copying and Moving of Objects    Delete    Delete the selected objects and all of it s child objects   See also  Deleting Objects    Apply    Apply a template or project definitions to the selected object   See also  Apply    Lock Tree    Lock the selected object and of it s descendants   See also  Locking Objects    Unlock Tree    Unlock the selected object and of it s descendants   See also  Locking Objects    Import    Open the import wizard to import data into PLA   See also  Import    Export    Open the export wizard to export data from PLA into a file   See also  Export    Logout    Log out of PLA  This will end your current session  You ll have to save or discard your current work   This will display the login screen     Exit    Close PLA     Reference    157    Help Menu    This topic describes the Help Menu of the PLA menu bar      Help Topics    Open the online help of PLA     Submit a Bug or Request a Feature    This allows you to connect to the Support Website of PLA to submit a feature request or a bug report   You will be asked whether PLA should connect you to the Support Website     PLA License    Open the PLA License Manager   See also  License Management    About    Open a window showing detailed information ab
42. ators  They manage users and define the security relevant options within PLA   Inspectors  They have read only access to the objects  but they are allowed to electronically sign objects     Data Integrity    PLA makes use of its own Public Key Infrastructure  All objects within the database are signed using a  digital signature  This signature is checked every time  PLA access the object  If the signature is  invalid for any reason  PLA refuses to open the object   In addition to the objects  projects  assays  standards  preparations and controls  even the user  accounts and the options are digitally signed too  All of these signatures include a unique database  identifier  This database identifier is verified each time an object is accessed   By these techniques it is not possible  to modify definitions or to move elements such as user  accounts to other installations without invalidating them  So don t try to modify anything in the PLA  databases     Database Security    The file based databases of PLA are secured  For the SQL Server based databases it is recommended  not to communicate the database access information directly to the user  The database administrators    PLA administrators should define the database connections for the end users  Another possibility is  to directly install the database connections via registry   Advanced Database Administration     PLA 2 0 User Manuals    130    Database Guide    PLA Databases    PLA makes use of databases to store assay dat
43. ble  from your computer  Attach the Software Licensing Module to your  computer s parallel port  Label  PARALLEL   and re attach the printer  cable to the backside of the software licensing module  Label  SERIAL     Computer System  lt  gt  Software Licensing Module  Dongle   lt  gt  Printer Cable  lt  gt  Printer    Install USB Universal Serial Bus Hardlock         Attach the Software Licensing Module  Hardlock  to a USB  Port of your computer    Getting Started    13    Basic Database Management    PLA 2 0 has a database management that allows you to create and connect to any number of  databases  You can create databases for your different projects allowing you to define who has access  to which data and to specify different security settings to these databases   The databases can be shared across the network  There are two basic database types available  File   based databases and SQL Server based databases   The installation process automatically installs a database called  PLA 2 0 Default Database   This is a  file based database with some example data   Since PLA 2 0 has its own security system  you have to create an administrator account  when you  create a new database  You are automatically asked to create this account  Do not loose the password  of this administrator account  Using this account  you can create any number of additional user  accounts      File Based Database    This database type is based on a secured Microsoft JET 4 0 database   Disadvantages      
44. chased directly from Stegmann Systems   You shall bear all costs for shipping and shipping insurance     PLA 2 0 User Manuals    188    WITH THE EXCEPTION OF THE WARRANTY STATED ABOVE  STEGMANN SYSTEMS GRANTS NO  OTHER WARRANTIES NEITHER EXPLICIT NOR IMPLIED WITH REGARD TO THE PRODUCT  AND  EXPRESSLY EXCLUDES WARRANTIES ON THE PRODUCT S ECONOMIC EXPLOITABILITY AND USE FOR  SPECIFIC PURPOSES   5  Compensation for Damage  Should Stegmann Systems be liable for damages to you or a third party for any reason  whether for  claims arising from this agreement or tortious liability  including ordinary negligence  the amount of  the damages to be paid is limited to the sum invoiced for the Product that caused the damage or for  the Product on which a claim for compensation from Stegmann Systems is based  However  this  limitation shall not apply if Stegmann Systems is responsible for the damage due to malice  aforethought or gross negligence  Stegmann Systems shall in no way be liable for damages caused by  violation of duty on your part  consequential damages  economic losses  damages due to loss of data  or for claims from third parties put forth against you   6  Termination of the Agreement  Should you fail to comply with the provisions of this agreement  your license and this agreement shall  be terminated  The provisions in paragraphs 3   4  and 5  shall remain in full force and effect even  after termination of this agreement   Version dated 2006 08 22    
45. d by an arrow        Rename Objects by pressing F2  You may also insert variables into the name  These variable  are useful if you want to create import definition schemes  The variables are replaced  when  the import is executed  The variables available are   U replaced with the name of the current  user   D replaced with the current date   T replaced with the current time and  F which is  replaced with the filename of the import file     Save the Import Definition Scheme  IDS     On this page you have the option to save your selection in an Import Definition Scheme  This scheme  contains all of your selections especially the raw data assignments  If you save it  it will available on  your next import with this file type  Note  the IDS is saved in the PTD file of your Import Module  PLA  needs write access to this file     User Guide    63     Summary    On the summary page parts of your selections are summarized  Press Execute to start the import  process     PLA 2 0 User Manuals    64    Export    The Export process is very easy  It follows a simple path     Select the Export Object    In the navigator select the object  you want to export  Then select Export from the file menu  the  navigator context menu or from the toolbar  The Export Wizard is displayed     Now you have the option to export all objects  or the selected object of the navigator  Press Next gt  to  display the file type selection     Select the File Type and Select an Export File    User Guide    65    Se
46. different PLA installations   This feature is very useful for the communication between different sites or companies  E g  to and  from your CRO    You can securely transfer        projects       assays       templates  First of all you can sign the objects using the Electronic Signature features of PLA  These signatures  can be transferred to other installations of PLA  The object is not modified until the signature is in  place   Then export the object using the PLA Secure Format  PSF   The PLA Secure Format makes use of the  internal Public Private Key Infrastructure of PLA  Any modification of the exported file is detected and  the import is prohibited when a modification is detected     PLA 2 0 User Manuals    94    Audit Trail    The Audit Trail of PLA is always enabled and cannot be manipulated with the help of PLA  Every  change of an object property or every other security relevant modification of the system is logged in  the audit trail   The audit trail information is split up into the main entry and details for the main entry   Each main entry contains       an unique entry number       a time stamp       an operator identification       the type of the entry as listed below       an object for the entry type  The following entry types are logged   USER_LOGIN  An user logs into the system    USER_LOGOUT  An user logs out    USER_LOGINREJECTED  An user has not been allowed to log into the system    USER_PWCHANGE  An user changes his password    USRMGMT_ADDUSER  An 
47. e   There are three types of configurations available        Full Curve  This is the default option  All treatments of the standard and the preparation are used for  analysis       Fixed Range  A portion of the curve is selected by hand  The treatments of each object are numbered and  you use these step numbers to select your regions of interest       Automatic Range Selection  There is a full list of range selection options available  for automatic selection of the significant  dose response curves in the parallel line analysis   The different configuration options can be defined for the standard and the preparations individually  allowing e g  to select a well known area of the standard and to automatically find a matching range  in the preparations      21    User Guide    Introduction to Assay Analysis with PLA    PLA is a full featured system for the analysis of Parallel Line Assays and Parallel Logistics Assays  This  manual describes the concepts and features of PLA  A systematic introduction can be found in the  My  First Assay with PLA  section   This manual covers the basic operation with PLA  The structure of the manual is        Connect to PLA  The chapter describes how to connect to an existing PLA database        Managing Objects  This chapter describes the basic handling of objects in PLA  This includes the management  and editing of the objects  Inheritance  Templates  the Apply function and import export  handling augments the chapter        Object Properties
48. e Groups for Combination of  Assay Results     Reference    143    Apply    This dialog allows you to apply object properties to multiple objects at once      Source Object    Select the source of the properties which will be applied to the target objects        Project  Use the selected project or the parent project of the selected object as source       Assay  Use the selected assay or the parent assay of the selected object as source       Template  Use a template as source  You can specify the template by selecting one from the template  list to the right     PLA 2 0 User Manuals    144    Property groups to apply    Select the property groups  which you want to apply  The groups correspond to the property pages of  the object editor dialog described here in Introduction     Target    Shows you to which objects the properties will be applied     Included Object Types    This allows you to filter the objects to which the properties will be applied by their type  The  properties will be applied to the selected object types only     Apply     Apply the selected properties     Close    Close this dialog     Reference    145    Audit Trail    Shows Audit Trail information by listing operations and their details      Operation List    A list of operations showing you which actions have been executed by which user at which time     Operation Details    If an action from the above list is selected  the details of the selected action are displayed if available     Refresh    Refre
49. e parts of the tree by selecting an object and pressing include and exclude  buttons  Excluded objects are marked with a black cross        Select another parent for the assays  This allows to import the objects to a different target  If  you selected an existing object as a target  this is noted by an arrow        Rename Objects by pressing F2  You may also insert variables into the name  These variable  are useful if you want to create import definition schemes  The variables are replaced  when  the import is executed  The variables available are   U replaced with the name of the current  user   D replaced with the current date   T replaced with the current time and  F which is  replaced with the filename of the import file     User Guide    53    The next screen shows the different options     In this sample  an existing project  Example 2  is the target of the operation  Assay 2 and Assay 3 are  excluded and Assay 4 is renamed to  Assay 4  U  which show the usage of a variable   Press Next gt  to see the summary page     Summary    Your settings are displayed on the summary page for final control  When you are ready  press Finish   to start the Importation     PLA 2 0 User Manuals    54    After you press finish  the data is imported to PLA     User Guide    55    Raw Data Import    When you installed a PLA Import Module the import process may become more complex  since the  Import Module might not be able to decide  how to deal with your raw data   Start the import as a 
50. ections      Database Connection Profiles    This list contains a list of previously created Database Connection Profiles  You can switch between  different databases simply by selecting the appropriate profile in the list     Create or Connect a Database File    Select this button to create a new connection profile for a Microsoft JET database file  MDB   To use  an existing PLA database  select the appropriate file in the appearing  Select File  dialog  You can  create a new database file if you enter a new file name in the  Filename  text edit field of the  Select  File  Dialog     Connect a Database Server    This option allows you to create a new connection profile using a database server   See also  Database Manager Connect    Delete Connection Profile    Click this button to delete the currently selected connection profile     PLA 2 0 User Manuals    152    Compact Database    This options allows you to compact the JET database described by the currently selected connection  profile   Note that using this function for non JET databases fails  since database compaction is only supported  for Microsoft JET databases     Open Database    Opens the database described by the currently selected connection profile     Close    Closes the Database Manager without switching the database connection profile     Reference    153    Database Manager Connect    This dialog allows you to set up a connection to a database server   Currently only Microsoft SQL Server 2000 or higher is 
51. eleted objects is still intact        The operation is not reversible     User Guide    33    Hiding Showing Objects    The  hide  feature allows you to exclude objects from calculation and from display in the navigator   You can decide whether to hide or show an object by selecting the  hide  checkbox in the General  section of the editor   At the bottom of the navigator there is a checkbox to include hidden items into the display of the  navigator     PLA 2 0 User Manuals    34    Locking Objects    PLA stores its objects in a multi user database  To prevent that two or more users modify the same  object at the same time  PLA locks the respective object  A locked object is decorated with a small  locked padlock  The first user who accesses the object gets the exclusive right to modify its contents   If a user has exclusive rights on an object  it is decorated with an unlocked padlock   PLA automatically handles locking and unlocking of all objects and there is normally no need to lock  objects manually  Even applying properties for a whole project tree is handled without further user  interaction   However  sometimes a user plans to perform extensive changes on a collection of objects  which  should not be disturbed by any other user  In this situation it is possible to explicitly lock the object  tree using the  Lock Tree  function of the navigator context menu   Notes         Lock Tree  will fail  if any of the descendant objects is already locked by another user        T
52. emplates        Protected Templates  Protected Templates can be created by administrators only  Standard Users are not allowed to  modify these templates        User Defined Templates  User Defined Templates can be created by all users  They are intended to be a tool     How are Templates Created     Switch to the Template mode of the navigator by selecting  Templates  from the drop down bow at  the upper of the navigator  Then select  Protected Templates  or  User Defined Templates  and select  the Create Object command to create a new template     An template object is created  You may now edit all properties of the template  They will be used for  the creation of new objects if the template is chosen     Complex Templates    The template engine of PLA can except complex templates  that allow differentiated settings for  standards  preparations and controls  If you select the Create Objects command on an existing  template  you are able to define sub templates for the different object types of PLA     PLA 2 0 User Manuals    44    If you select a template in section 3 of the Create Objects dialog  PLA will use a sub template of a  matching object type  if this is available     User Guide    45    The Apply Method    In contrast to the Inheritance and Template mechanisms of PLA  the Apply method allows you to  mass modify object properties after an object has been created   Select an object and select the Apply command from the file menu or the navigators context menu   The 
53. eration when validating a software     Validation of Each System    A software vendor is in principle not able to deliver a validation statement with the software  Not only  the software can have errors that are critical to the results  but also each single computer system has  to be considered as a potentially defective system  There are many sources of errors within the  computer system  The random access memory  CPU  hard disk  the operating system are able to  cause different errors that are quality critical  E g  in the past even the CPU could cause mathematical  errors  Defective non error correcting RAM is able to vary calculation results  Defective hard drives can  modify quality critical components of a software system   This all leads to the conclusion that every single computer has to be validated  It is not enough to  validate an exemplary system   PLA 2 0 is fitted to allow a very fast validation of your system  The different components of the  Validation Infrastructure of PLA are optimized to efficiently deliver the required tasks to you     Cryptographically Secured Reference Data    PLA 2 0 is delivered with cryptographically secured reference data sets for the Installation  Qualification  IQ  and the Operational Qualification  OQ   The use of cryptographically secured digital  signatures assures the integrity of the reference data  PLA makes use of a public key cryptographic  system  Only Stegmann Systems is able to publish these reference data sets   For the
54. erial number of PLA   With this information a qualified machine can easily be identified  The certificate should be printed out  an signed by the operator     Optional Components of PLA    Report Templates and Import Export Modules come with their own IQ file which is secured like the  base system IQ file  The IQ files are located in the component directories  If PLA finds such IQ files   they are checked during the IQ too  So you should re evaluate the Installation Qualification after you  installed or un installed any optional component  The IQ certificate clearly tells which packages have  been included in the process     PLA 2 0 User Manuals    116    Performing the Installation Qualification    The processing of the installation qualification could not be easier than in PLA  Simply select the   Installation Qualification  IQ   from the Validation menu of PLA  Then click Start to start the process   After a few seconds a report containing the certificate is created in the PDF format  The report is  secured from manipulation using a one time password that cannot be recovered by PLA     Click on the hyperlink in the result section of the wizard to open the certificate  The certificate is  created in the default report directory of PLA   If the Installation Qualification fails  there have been modifications to the system  In general the  system should be re installed then  Thoroughly check the error report  you receive to understand   what has changed in the system and why t
55. espect to this standard object    Note  Some analysis properties of the standard are grayed out because they are  taken from the respective preparation object       Preparation  Sample  Unknown   The second type of third level objects is the preparation object  PLA calculates the  potency of the preparation object with respect to the standard object  Many  calculation properties are taken directly from this object  An assay object needs at  least one preparation object to be calculated      Control  The third type of child objects of the assay object is the control  A control contains  data for a series of positive  negative and blank controls  The use of control objects  in PLA is optional     The following graph illustrates a typical navigator view with these kinds of objects     PLA 2 0 User Manuals    28     User Guide    29    Creating Objects    New objects can be created either by import data or by manually selecting the  Create Object   function  menu  toolbar  navigator context menu   This section describes the manual function   If you want to create a new object  you have to select a neighbor object in the navigator and then  select the  Create Object  function   Neighbor  object has the following meaning        if you want to create a new project  select anything or nothing       if you want to create a new assay  select any object that is a child of the project which shall  be the parent project or the project itself       if you want to create a new standard  pre
56. figure  PLA 2 0 Default Database  and the logged in user  fig   PLA Administrator     PLA 2 0 User Manuals    24    The Objects of PLA    User Guide    25    Managing Objects    The Navigator    Once you have logged in  the main instrument of work within PLA is displayed  the Navigator  The  navigator allows you to navigate through your connected database     The navigator displays the objects defined in the database in their hierarchical order   The user selects an object and then selects an action available for the object  To select this action  there are three ways        select an action from the context menu by clicking the right mouse button for the object  A  context menu as shown in the figure pops up  Then select the desired action by a left click in  the context menu       use the toolbar area to select an action       use the menu system to select an action  In addition you may simply double click an object to open the object editor   There are a few more options available for the navigator        on top of the navigator there is a drop down box which allows to the  Data Objects   as  shown in the figure  or the  Templates         in the button line there is the option to display  hidden items  and    PLA 2 0 User Manuals    26         to select the automatic refresh of the navigator which may by useful if you are working  together with other users in the same database  If you select the refresh function the  navigator will automatically be refreshed after a certai
57. following dialog appears     This method allows to copy properties of a source object to selected targets   The dialog is grouped into three sections   1  Source Section  Select the source of the properties you want to apply to the targets  Available source objects are the  parent project  the parent assay or a template   2  Property Selection    PLA 2 0 User Manuals    46    Select the groups of properties you want to apply  By default the analysis settings and the  configuration optimization settings are selected   Warning  If you execute apply  you cannot undo the changes  check the selected property groups  carefully   3  Target Filter  Select the objects types that are targets of the apply method   After you have carefully checked the settings you may execute the apply     User Guide    47    The  Inherit Properties  Property    To reduce the complexity of assay definitions the  Inherit Properties  option is available  For the  following three groups of properties the Inherit Properties property binds the properties of an  standard  preparation or control to the corresponding properties of the assay object  These properties  are kept in sync with the assay properties automatically   If you select the option  all other values of the property page are grayed out   The  Inherit Properties  property is available for these groups of properties        Analysis settings       Configuration optimization settings       Dose settings     PLA 2 0 User Manuals    48    Import and Ex
58. ght of use to exploit utilize the Product according to the following  You are not  authorized to transfer the Product or parts thereof to third parties  or to make them accessible in any  way  or to modify  disassemble  decompile  reverse engineer  process  or improve the software  or  other parts of the Product  or to attempt to discover the source code of the software with the  exception of the conditions as stated in Section 69e of the German copyright law  You have the right  to install and use the Product on one  1  computer  If you want to install and use the Product on  other computers  you must acquire and dedicate a license for each separate computer  You have the  right to make one  1  copy of the software in order to archive it   2  Other Rights and Limitations  If the Product is labeled as an upgrade  you must be properly licensed to use a product identified by  Stegmann Systems as being eligible for the upgrade in order to use the Product  A Product labeled as  an upgrade replaces and or supplements the product that formed the basis for your eligibility for the  upgrade  You may use the resulting upgraded product only in accordance with the terms of this  license agreement  If the Product is an upgrade of a component of a package of software programs  that you licensed as a single product  the Product may be used and transferred only as part of that  single product package and may not be separated for use on more than one computer   You may not rent  lease  or le
59. he installation qualification fails  Not every change  necessarily compromises the system  but you should only continue to use PLA  when you successfully  verified  that the system is intact   Figure   A certificate of the IQ process  sample pages     Validation Guide    117      PLA 2 0 User Manuals    118    Operational Qualification    The Operational Qualification Process    The Operational Qualification  OQ  of PLA checks the mathematical functionality of the system  PLA is  fitted with a suite of 22 OQ Packages  These packages are designed to check every aspect of the  mathematical functionality     How does it work     The automated OQ of PLA is devided into the following processes   1  The assay data is decoded from the PLA OQ file  During this process the digital signatures of  package is verified using PLAs internal PKI  If the data is valid  the OQ processor imports the  data into a temporary project   2  The temporary project is calculated by PLA  PLA fills its internal result structures with the  calculated data   3  The internal result structures are compared to the result structures saved and secured in  PLA OQ If any error occurs the Automated OQ fails   After this procedures has been executed with all 22 OQ Packages an OQ Certificate or an OQ Failure  Report is generated   If the OQ fails the corresponding PLA Installation has to be checked thoroughly  First of all the IQ  should be processed  If it fails  reinstall PLA  If the IQ passed  though the OQ failed
60. he user should not forget to unlock the objects using  Unlock Tree  if the work is finished        Locking an object tree will prevent any other user to work with any object within that tree   This might bar your coworkers to work at all     User Guide    35    Editing Objects    The Editor    Once you select the Edit Object function in the file menu  the toolbar  or in the context menu of the  navigator the Object Editor opens in the sheet area of PLA  The figure below  shows an opened Object  Editor for the Assay with the name  Assay 1      The object editor consists of two areas        the tab page area  where tab pages control the display of groups of properties  In the figure above the General  tag page is selected  There are seven other pages available        the information area  is at the bottom  In this area some notifications  warnings or errors may be displayed  In the  figure there is note on outlier testing visible   You may close the window by selecting Close Window function from the file menu or by clicking on  the upper right cross of the object editor  If some properties are changed  you will be asked whether  you want to save the object  If nothing changed  the editor is simply closed   You may also select the Save Object function of the file menu or the toolbar to save an object     PLA 2 0 User Manuals    36    Property Pages    Any object of PLA is described by a set of properties  These properties can be separated into the  following groups  which are di
61. her  You may install and un install them in any order     Data Migration    The installation of PLA 2 0 does not touch your current PLA 1 2 data  If you want to migrate your data  you have to export them in PLA 1 2 and then import the corresponding data file in PLA 2 0     PLA 1 2   PLA 2 0 Licensing    If you have purchased a license of PLA 1 2 and obtained your license of PLA 2 0 with the PLA Upgrade  Protection or via an PLA Product Upgrade your are entitled to use both versions on the same  computer system  You must not install both versions on different computers   Note  This licensing feature is only available in the per seat licensing mode  PLA 1 2 does not support  floating licenses      181    Stegmann Systems    Stegmann Systems  formerly known as Stegmann Systemberatung  has been founded 1996 and is  located in Germany   Stegmann Systems  Raiffeisenstr  2 C1   C2  63110 Rodgau  Germany  Phone   49  0 6106 77010 0  Fax   49  0 6106 77010 29  E Mail  support bioassay de  Website  www bioassay de  Support Website  support stegmannsystems com     183    System Requirements    Your computer needs to meet the system requirements in order to run PLA  Please remind that you ll  need administrative rights to install PLA          System Requirements        Intel Pentium III  or compatible  Processor with 1Ghz or higher       512 Megabytes of System Memory  RAM  at least       250 Megabytes of free Hard disk space       Microsoft   Windows 2000  Microsoft Windows XP          
62. inspected from the System menu  The audit trail information of a  single object can be inspected on the audit trail tabpage of the assay editor   Figure   Audit Trail Inspection from the system menu    Figure   Audit Trail Page of the Assay Editor    PLA 2 0 User Manuals    96      97    My First Assay with PLA    My First Assay with PLA    Note  This initial tutorial is available as a tutorial video in the online help  too   This tutorial shows every step from the raw data to a complete assay definition in PLA   There are three main parts   1  Definition of the Assay and Data Input  How to structure and define the assay in the PLA database   2  Exploring your Assay  Modify the Analysis options  Take a tour through the basic graphical analysis of the assay   3  Final Computation and Reporting  Finalise the computation and create reports for the assay     PLA 2 0 User Manuals    98    The Exemplary Data    Our assay consists of a standard and a preparation  whose potency is to be calculated  As we will see  the data has a highly sigmoid structure  The assay is a dilution assay with a 1 in 2 dilution series   Both  standard and preparation have twelve treatments  that are measured as triplicates   The standard has the following response values   Dose Response  Replicate 1  Replicate 2  Replicate 3    1 1  0 722  0 71  0 734    1 2  0 707  0 75  0 734    1 4  0 655  0 69  0 713    1 8  0 607  0 664  0 628    1 16  0 512  0 506  0 507    1 32  0 325  0 382  0 376    1 64  0 231  
63. io after calculation     Outlier Detection  Method  Select the Outlier Detection Method        None       Dixon Test       Grubb s Test       Test based on Standard Deviation       Studentized Residuals  not available for controls     Contamination  alpha  Sensitivity of the outlier method   not available for Standard Deviation Method     recursive testing  execute the outlier tests recursive    Only for Dixon and Grubb s Method     n  Multiplicator for Standard Deviation test    Hypothesis Testing  ANOVA Model    The ANOVA model for the analysis        ANOVA based on Pure Error Separation       ANOVA Residual Error       Separate ANOVAs for each hypothesis  PLA 1 2 compatible     Regression  Significance     Significance of the F Test for Regression    rejection criterion      reject assay if F Test of regression failed    Linearity  Significance     Significance of the F Test for deviations from linearity    rejection criterion      reject assay if F Test of linearity failed    Test for  Parallelism    The parallelism test method  F Test  Equivalence Test Ratio of Slopes   Equivalence Test Difference of Slopes    Significance of  Parallelism Tests       Significance level for the selected parallelism test method    rejection criterion     reject assay if test of parallelism fails    User Guide    75    Equivalence  Testing Goalpost       The upper and lower goalpoast of the equivalence test     Confidence Interval  Confidence  Interval  The confidence interval of the potenc
64. ions    1    Height  pixel   1  Defines the height of the image in pixel created when saving the graph from  the Data Explorer to an image file   2     Possible Values 100   2 048  Default value  600    3   2    Width  pixel   1  Defines the width of the image in pixel created when saving the graph from  the Data Explorer to an image file   2     Possible Values 100   2 048  Default value  800    3          Search for Updates    1    Search for News and Updates  1  Defines how PLA should check for News or Program updates   2     Possible Values 1   Automatically check for news and updates at startup  2   Allow manual check for news and updates at startup  3  Disable check for news and updates  Default value  1   Automatically check for news and updates at startup  2          GMP GLP SOP Settings    1    Default Template for the creation of projects  1  Defines the default template for the creation of projects   2     Possible Values 1    none   2  n   A list of your templates  Default value  1    none   2   3    GMP GLP Master Protection    PLA 2 0 User Manuals    164    1  Enable or disable GMP GLP Master Protection  Enabling this option overrides  all set GMP protections   2     Possible Values Off  On  Default value  Off  4   5    Projects may be created by administrators only  1  If this option is enabled  only administrators are allowed to create projects   2     Possible Values No  Yes  Default value  No    6       Users may not delete objects  1  If this option is enab
65. l options you are able to detect problems with your  assay  Using the ad hoc template feature of the explorer you can test the analysis of your assay with  different analytical options  without modifying the definitions of your assay   The Assay Explorer fulfills another important function for assay analysis  a responsible analysis  requires the graphical inspection of your assay  Thoroughly check the response data of your  assay for plausibility  No statistical test is able to detect plausibility problems   Further reading        Explore your Assay       Combination of Assay Results       Calculate your Assay       Report Analysis Results    PLA 2 0 User Manuals    84     Explore your Assay    The Assay Explorer has a wide range of options for graphical analysis     On the right side there are several groups of options and informations     Graph Type    The graph type distinguishes between the dose response graph  shown above  and the goalpost  graph that is available only when equivalence testing is chosen as the method of parallelism test     Display Options    User Guide    85    The display options allow to modify the displayed graph   show legend  toggle the display of the legend    show grid  toggle the display of the grid    regression lines  toggle the display of the regression lines    regression line type  switch between the restricted or the unrestricted regression lines  Use  the unrestricted regression lines to get an impression of the quality of  the fit    mea
66. layed as  1  A 1  330 895   which has to interpreted as follows   point     Object_code Dilution_step   response_value   Every object has an automatic assignment to a letter  starting with A  for the standard  Every letter  has a color code  You can see the assignment of codes to the objects by opening the drop down list  box in the selected datapoint section  The dilution steps are numbered   Assignment by Keys  If you select multiple response values in the grid you may simply type the letter of the desired  assignment  to assign values to an object  By type a space  you remove the assignment  By pressing 1    9 you assign a selected response value to a dilution step  By pressing 0 you remove the assignment  to a step  This allows you to select your block designs and assign them to the response values in a  hurry   The next picture shows a sample assignment     User Guide    61    When you have finished your assignments  and there no errors  which are displayed in the dialog  the  Next gt  button is activated     The Object Import Tree    The PLA Import Wizard now displays the Import Tree     PLA 2 0 User Manuals    62    On this page you have several options        Include and Exclude parts of the tree by selecting an object and pressing include and exclude  buttons  Excluded objects are marked with a black cross        Select another parent for the assays  This allows to import the objects to a different target  If  you selected an existing object as a target  this is note
67. lect the file format you want to use and then press  Select  to open a Save dialog of the operating  system     Type in a file name and press  Save   In the Export Wizard press Next gt  to switch to the Export  Details page     Export Details    Depending on your selected export format  you may select the information details to export     PLA 2 0 User Manuals    66    The PLA Secure Format and the PLA External Format do not allow to select details  Press Next gt  to  continue     Summary    On the summary page you can verify your Export details  Press Execute to start the export process   You will be notified when it is finished     User Guide    67     PLA 2 0 User Manuals    68    Object Properties    Introduction    The representation of projects  assays  standards  preparations and controls are generally called  objects in this manual  The object properties can be divided into different sets of information  They  are represented as property pages in the object editor dialog        General Properties  contain general information about the specific object        Dose Properties  define the potency and doses of a specific measurement object       Data Properties  define the dimensions of the response value matrix and allow the input of the dose and  response values       Analysis Properties  are the details of the calculation parameters       Configuration Properties  fine tune the configuration selection in PLA       Documentation Properties  allow the specification of vari
68. led  standard users are not allowed to delete projects or  assays   2     Possible Values No  Yes  Default value  No    7          Security    1    System Idle Lock Interval  1  This specifies the time interval  in minutes   after which PLA is locked if no  user action occurred  By specifying the value 0  the automatic lock is  disabled   2     Possible Values 0   1540  Default value  0  2   3    Password minimum length  1  Specifies the minimum number of characters a password must have   2     Possible Values   0   25  Default value   0  Recommended Value 8    4   5    Password minimum number of special characters  1  Specifies the minimum number of special characters a password must  contain  A special character is one of  0123456789       _                  amp      lt  gt    2     Possible Values 0   n  Default value  0    Reference    165    6       Password maximum age  1  Specifies the maximum age of a password in days  If the age for a password  has been reached  The user will be asked to change it  By setting this option  to 0 you disable it   2     Possible Values 0   n  Default value  0  7   8    Password warning age  1  Specifies the warning age of a password in days  If the age for a password  has been reached  The user will be notified that his password will expire  By  setting this option to 0 you disable it   2     Possible Values 0   n  Default value  0    9       Password minimum age  1  Specifies the minimum age of a password in days  The password cannot  e
69. lism test is displayed in green or red fields as passed  or failed   The potency ratio  not potency factors  of the assay are displayed including the corresponding  confidence intervals     Selection Section    PLA 2 0 User Manuals    86    Below the graphic the selection section is displayed  By checking and un checking preparations you  can modify the display  The bullets indicate the test status of the preparation   green   all hypothesis tests are passed  yellow   the linearity or regression tests failed and are not marked as rejection criterion  red   the parallelism test failed or a test failed  that is marked as a rejection criterion    Graphics    The graphics shows the dose response graph or the equivalence test graph     The disk symbol allows to save the graphic as a JPEG or PNG graphic for further use in  publications etc  The dimensions of this graphic can be set in the options dialog     User Guide    87    Combination of Assay Results    Combination of Assay Result calculations are available within PLA  To prepare these calculations  you  have to add the preparations you want to combined to combination groups  A combination group is a  simple named label  that allows PLA to analyze which preparations are combined  The labels can be  edited on the documentation page of the Assay Editor or with the Combination of Assay Results  Editor   PLA will calculate the combination  when a group contains more than one preparation and the  appropriate option on the Calculate
70. lity of  PLA   Beside this approach of inheritance  there are more advanced concepts of templates  GxP and SOP  support  These approaches are described in detail in the user manual     Getting Started    17     Basics of PLA 2 0 Mathematical Features    PLA 2 0 is a full featured system for the analysis of parallel line and parallel logistics dilution assays   The statistical features of PLA are described in detail in the Statistical Reference   In this section  you will find information on       Doses and Potencies       Model  Response Transformations and Outlier Detection       Analysis of Variance  ANOVA        Configuration Selection    Doses and Potencies    PLA is able to calculate different potency values found in today s requirements of assay analysis  In  principle  you have four different starting points for potency analysis   1  Bulk Substance   Raw Material Potency  When you activate the bulk substance potency you can input the potency of your raw  material  You have to specify how much amount of your raw material is solved in which  amount of a solvent  PLA then automatically calculates the concentration potency of your  stock solution  which is the starting point for your dilution series   2  Stock Solution Potency  Another option is the direct specification of the stock solution as a starting point  If you do not  specify a bulk substance raw material potency or stock solution potency the latter is assumed  as 1 0  3  Pre Dilution Potency  You can specify two 
71. llowed to move child objects of signed assays   To use the copy   move functionality first select the object of interest  Then select the copy or move  function from the file menu or the context menu of the navigator  The following dialog is displayed      Note  the Move dialog is identical to this one    Within the dialog there are two sections   The source section has already been filled with the object of interest  If you have select a project or  assay object  the copy dialog allows you to decide wether to include all child object   Move always  includes the child objects    You now have to select a target parent  By default the parent of the source is selected as the target  parent  You can make use of the button right to the target field  This opens a dialog with all the  available objects  You may rename the object by typing a new name into the name section   Select  Copy  or  Move  to start the execution  When the operation is finished the dialog close and the  navigator tree is refreshed     PLA 2 0 User Manuals    32    Deleting Objects    You can delete objects by calling the delete function from the file menu  the toolbar or the context  menu of the navigator  The object must not be locked or signed  You will be asked to confirm the  delete operation  if you choose a project to delete  there will a second security confirmation   After  you have confirmed the operation the objects will be removed from the database   Notes        The audit trail information of the d
72. llowing functions  the requested  calculation is taken out and the report is created   Preview opens the report by starting the appropriate application   Print prints to the standard printer of the system  If you want to print to alternative printers  use  Preview and the print function of the application   Save opens a save dialog of the operating system and save the report to the selected file     Combination of Assay Results    If you want to calculation the defined combination of assay results  the option has to be activated     PLA analyzes the defined combination of assay result groups and adds the required assays to the  calculation  This will need additional computation time     Default Reports    By default PLA is delivered with seven different report templates  Further report templates or  individual report templates  including company information etc  can be ordered from Stegmann  Systems   The following reports are available     PLA 2 0 User Manuals    90    Assay Documentation  requires Microsoft Word 2003 or higher   This is a report for documentation of the assay  It contains properties and data  Calculation results are  not included   Combination of Assay Results  requires Adobe Acrobat Reader   The report contains only the combination of assay results data   Complete Statistics Report  requires Adobe Acrobat Reader   This report should be considered as a default report  It documents the assay  includes all of the  ANOVAs and regression results and the potency
73. ls  If your dilution scale property is set to direct dose input  you may  input dose values  not response values  on the assay and project level too  These dose values are  used as default values if you create new objects within these ones   The following figure shows the data editor of an object     There are three properties defining the dimension of the editor        The number of treatments  dilution steps   defines how many lines are available       The number of replicates defines how many response columns are available       The dose scale setting switches between the  1 in 2  twofold series and the direct dose input   In the latter case you have to input the relative dose values within the editor   If you check the preview absolute doses button  an additional read only column appears  that  displays the absolute dose values in dependance to the settings of Doses tab page  This may be  useful to understand the richness of dose features of PLA   To mark a value as technical outlier  use the F3 button  This button toggles the technical outlier  status of a response values  With the F2 button you can switch the editor between navigation and  input mode   Cut and Paste is available  too  Simply mark the values of interest and press Ctrl C to copy them to  the clipboard and Ctrl V to paste the clipboard contents into the editor  Note that the editor has to be    PLA 2 0 User Manuals    38    in navigation mode  if you want to paste multiple values  The cut and paste is the 
74. mension  2  The Configuration Optimzation Option  3  The Analysis Options    Assay Dimension    The standard and the preparation both have twelve treatments  dilution steps  and three replicates   Now open the assay  if not already open  and move to the data page     Set the number of treatments and the number of replicates     Configuration Optimization    We will start with the Full Range option set  This leads to the inclusion of all data points in the  computation  Select the Configuration page and set the optimization method to  Full Range      For easier maintenance in the case we want to switch this method  we decide to switch on the  Inheritance Property      My First Assay with PLA    103    Analysis Options    We now have to select the analysis options  We want to start with the parallel line method  We select  the analysis of the editor and select the following   Model  parallel line method  Significance of Regression and Linearity  98   Inherit the Analysis Properties  Yes    Once we have set these options  save the object  from the file menu or the toolbar  and close it     Create The Standard Object    Now select the assay  Assay  in the navigator and create a  New Standard as member of assay   Assay    This new object already has inherited all properties from the assay object  Switch to the data  page and type in the response data for the standard     PLA 2 0 User Manuals    104    After you have finished save the standard and close it     Create The Preparatio
75. n Object    Now select the assay  Assay  in the navigator and create a  New Preparation as member of assay   Assay    This new object already has inherited all properties from the assay object  Switch to the data  page and type in the response data for the unknown     After you have finished the input  save the object  Do not close it     My First Assay with PLA    105    A First Look    Once we have finished data input  we should visually inspect the object  If it is not already open  open  the preparation   Note you can start the visual inspection from any object of the assay  Only the first  display is influenced by the selected object  If you start from the assay  all preparations are included   If you start from a specific preparation  only this is displayed by default    Now select the Check button from the toolbar or start Check from the file menu  The Assay Explorer is  displayed and preliminary result is calculated   Never communicate this result  always run a final  calculation      As expected the hypothesis regarding the validity of assay fail  We have selected Full Range for the  configuration  which is a bad choice for this assay   With the Assay Explorer you cannot manipulate data  So take the chance and try all options of the  dialog     PLA 2 0 User Manuals    106    We should now try to optimize our configuration  to achieve a valid parallel line assay     My First Assay with PLA    107    Optimizing the Configuration    In a sigmoid example it is necessary 
76. n line  display a line through the means of the treatments    include statistical  outliers  display the statistical outliers in the graph    include technical outliers  display technical outliers  This is available when statistical outliers are  displayed too     error bars  display the error bars of the treatments    box and whisker plot  display box and whisker graphic    standard deviation  multiplicity of the standard deviations for error bars and box and  whisker plots    invert x axis  toggle the direction of the x axis  Note  PLA 1 2 has an inverted x axis     show y axis origin  include the y axis origin in the graph    y axis transformation  change the y axis transformation  This option allows to inspect the  influence of other response transformations on heteroscadescity    Note  this does not change the response transformation      include outliers in  graphic transformations  check to neglect the outlier status for error bars  mean line and box  and whisker plots     Preliminary Calculation Results    Note  Final calculation results are found in the reports  These values do not reflect every aspect of  analysis     Note  Select a preparation in the selection section below the graphic to display specific results   Carefully check  that the preparation of interest is selected  Its name is displayed in this section   The preliminary calculation results indicate the status of the hypothesis tests  The status of the  regression test  the linearity test and the paralle
77. n number of seconds  which may be  defined in the system options   The navigator displays the objects in hierarchical order  Objects of the same type are displayed  alphabetically  You may resize the navigator by shifting its right border  You may also toggle its  display by a menu and a toolbar function  The latter can be useful if you analyze your assay using the  ad hoc explorer and if you have only a limited screen resolution available     User Guide    27    Object Types and Hierarchy    PLA makes use of five different object types that define your projects and assays      Project  Projects collect your assays  They are on the first level of object hierarchy and they  can be considered as folders  The properties you define for your project is never  used for calculation  It is used as the source information for inheritance      Assay  Assay objects are on the second level of object hierarchy  The assay is the parent  object for the standards  preparations and control values of your measured assay   The properties you define here are not directly used for calculation  they are source  properties for inheritance  However you may bind the properties of the child objects   standard  preparation  control  to these values  to obtain a single point of change      Standard  Reference   The standard object is a third level object and it is a child object of the assay  Each  assay needs a standard object to be calculated  The potency of the preparation  object is calculated with r
78. n this directory should not be modified during normal operation of the system        Shared components of the vendor  These are installed in Common Files sections  They are  used by different programs of the vendor        System components are installed in the windows directory  They add new functions to the  operating system or install new components or drivers   A basic requirement of the Installation Qualification is a computer system with a operating system  installation without errors  The installation qualification process than assures that all installed files of  the software system are installed in the correct directories  It is proven that they are identical to the  vendor distributed files by the calculation of a checksum  This checksum is cryptographically secured   The basic goal of the installation qualification is to prove the correct distribution of the right files on  the computer system     Result of the Installation Qualification    As a result of the installation qualification you receive a certificate that contains information on all files  of the PLA system  Their location and the details of the inspection  The certificate will only be printed  when the check is successful  If the check found errors no certificate but an error report is printed   The Installation Qualification certificate contains detailed information on       the date the IQ was performed       the user who performed the test       the workstation id       the detailed build number and s
79. ncy of the raw material given as a number and the  numerator of the units  E g  if the potency is 5 IU ug type in 5 and IU   The denominator has to be given in the amount units     Amount  The amount of raw material used  In the above example the amount  has to be given in ug     Solvent Volume  The volume in which the used amount of raw material is solved to  give the stock solution  Type in the volume and the volume units     Assume identical  potency of  standard and  preparation    The assumed potency of the preparation raw material is identical with  the assigned potency of the standard     Stock Solution  Stock Solution  A stock solution potency is given  The calculation results will contain a  potency estimation for this stock solution    Assigned Assumed  Potency  The potency of the stock solution given as a number and a unit string     Assume identical  potency of  standard and  preparation    The assumed potency of the preparation raw material is identical with  the assigned potency of the standard     Pre Dilution  Pre Dilution  Pre Dilution factors are given  The pre dilution factors define factors  between the stock solution concentration and the concentration of the  dilution series    Pre Dilution Factor  The Pre Dilution factor given as a fraction     Additional Pre   Dilution Factor  A second pre dilution factor given as a fraction     Include Pre   Dilution Factor in  potency ratio  estimation    If checked the pre dilutions are included in the calculations 
80. nd its validity is statistically proven   The complex statistical analysis of these methods requires an advanced software solution to be easy   flexible and efficient  This is the mission of PLA 2 0       PLA 2 0 User Manuals    8    Installation of PLA 2 0    If your computer system complies with the system requirements  the PLA 2 0 setup process is easy  and convenient  For the installation process administrative privileges on you computer system are  required     CD ROM Version of PLA 2 0    Insert the CD ROM into your CD drive  PLA 2 0 Setup should be executed automatically  If you have  the auto run feature of your disk drive disabled  Please start setup exe by using the Windows Explorer  or by selecting Run from your Start menu  The program to be executed is   lt DriveLetterofCDDrive gt   setup exe  e g  D  setup exe     Download Version of PLA 2 0    Please download the current version of PLA from the vendor s website  www bioassay de  and run the  downloaded executable  e g  PLA20 build601 exe    Note  There may be a security warning of you computer system when you try to execute a  downloaded program   The PLA Setup now initializes     PLA Upgrade    If you already had installed a previous version of PLA  the old version has to be un installed first  PLA  Setup is able to handle this for you and you will receive the following warning message  Note  the Yes  and No answers are localized    Select YES to uninstall the old version  No data will be lost     Accept the Te
81. nd the Product  You may permanently transfer all of your rights under  this license agreement  provided you retain no copies  you transfer all of the Product  including all  component parts  the media and printed materials  any upgrades  and this license agreement   and  the recipient agrees to the terms of this license agreement  If the Product is an upgrade  any transfer  must include all prior versions of the Product   3  Warranty  For a period of twelve  12  months after the delivery date  Stegmann Systems shall guarantee   a   that the performance of the software corresponds in all essential characteristics to the description in  the manual  provided the software is used with the appropriate hardware and  b  that the medium  on  which the software is to be stored  is free of material and manufacturing errors   4  Limitation of Liability  In the event of a breach of warranty  Stegmann Systems shall be exclusively obligated at its own  discretion to repair or replace the Product or parts thereof  In the event that Stegmann Systems  should not be in a position to fulfill this obligation  you are entitled to rescind the purchase  agreement  Warranty claims must be submitted to Stegmann Systems in writing within the warranty  period and at the latest within seven  7  days of the defect s appearance  and the defect must be  documented  Defective Products should be returned to the distributor from whom the Product was  originally purchased  provided that the Product was not pur
82. ng    For the final computation we select the assay or any child of the assay in the navigator  Then we start   Calculate  amp  Report  from the file menu  the navigators context menu or from the toolbar   The Calculation dialog appears     Select a Report and press Preview  Print or Save  The final calculation is started and the report is  generated  After the generation process finished  the desired action takes place and you receive your  report of interest      113    Validation Guide    Welcome to the PLA 2 0 Validation Package    To achieve GxP compliance your installation of PLA has to be validated  This validation is a very time   consuming step if you do not have automated methods available   With the help of the PLA Validation Package you are able to reduce this effort to an absolute  minimum   The PLA Validation Package is a separately sold solution that contains all information typically needed  for a successful validation of PLA 2 0  The license dialog    What is included in the package          Installation Qualification  IQ  Documentation       Automated Installation Qualification IQ       Operational Qualification  OQ  Documentation       Automated Operational Qualification OQ       Performance Qualification PQ Guidelines       Automated Creation of PQ Datasets and Documentation       Automated Performance Qualification PQ Processing    PLA 2 0 User Manuals    114    Principles of Validation    There are some basic principles which have to be taken into consid
83. o change your password   See also  Change your password    Administrative Database Access    This option allows you to en  or disable the administrative  database access for database maintenance   See also  Database Maintenance    PLA 2 0 User Manuals    174    Check Database Consistency    Perform a database consistency check     Session  amp  Lock Manager    Open the Session  amp  Lock Manager   See also  Session  amp  Lock Management    Audit Trail    Open the Audit Trail Dialogue for the selected object   See also  Audit Trail Dialogue    Lock PLA    Lock your PLA Session   You will need to enter your password to unlock the session     Reference    175    System Locked    This dialog is shown to you after you have logged your PLA Session manually via the System Menu or  after your session has been locked automatically  because you didn t work with PLA within the in the  Options specified time period      Current User    The name of the user  who s session is locked     Password    Type the password for the user into this field   Remember that passwords are case sensitive     Unlock    Click here to unlock the PLA session after having entered the correct password into the corresponding  field     Close PLA    Click here to close PLA  You do not need to provide a password   You will be asked whether you are sure about closing PLA  since all changes will not be saved     PLA 2 0 User Manuals    176    Validation Menu    This topic describes the Validation Menu of the PLA men
84. object types that define your projects and assays      Project  Projects collect your assays  They are on the first level of object hierarchy and they  can be considered as folders  The properties you define for your project is never  used for calculation  It is used as the source information for inheritance      Assay  Assay objects are on the second level of object hierarchy  The assay is the parent  object for the standards  preparations and control values of your measured assay   The properties you define here are not directly used for calculation  they are source  properties for inheritance  However you may bind the properties of the child objects   standard  preparation  control  to these values  to obtain a single point of change      Standard  Reference   The standard object is a third level object and it is a child object of the assay  Each  assay needs a standard object to be calculated  The potency of the preparation  object is calculated with respect to this standard object    Note  Some analysis properties of the standard are grayed out  because they are  taken from the respective preparation object       Preparation  Sample  Unknown   The second type of third level objects is the preparation object  PLA calculates the  potency of the preparation object with respect to the standard object  Many  calculation properties are taken directly from this object  An assay object needs at  least one preparation object to be calculated      Control  The third type of child 
85. objects of the assay object is the control  A control contains  data for a series of positive  negative and blank controls  The use of control objects  in PLA is optional     The following graph illustrates a typical navigator view with these kinds of objects     PLA 2 0 User Manuals    16     Inheritance of Object Properties    The understanding of object inheritance is necessary to make efficient use of PLA  The concept of  object inheritance is derived from the fact that during normal course of laboratory life you will be  analyzing many assay of the same type  To reduce input effort and errors PLA has many useful  options to initialize new elements of your assay with correct properties   Assays with identical properties can be kept together in a single project  You can define the initial  values of new assays in the projects properties  If you now create a new assay within this project  all  properties of the new assay are inherited from the project  You do not have to input any properties if  these properties match your needs  Now you can create the third level objects of your assay   Everything you need to enter are the object names and the response values of your measurement   IMPORTANT  If you change properties of parent objects  these changes do not influence the child  objects if you did not bind the child objects to the parent explicitly  available on the third level only    If you want to deploy new settings to child objects you can make use of the Apply functiona
86. oft JET 4 0  and SQL Server based  databases  Microsoft SQL Server  Oracle  can be distinguished   Due to regulatory needs PLA has its own user account management  User account is stored per  database  This makes for users especially in development labs to differentiate their security needs per  project   PLA is multi user networking aware  Objects in the databases are automatically locked when they are  used  The session and lock management of PLA is self healing if they encounter problems  e g   missing logouts   After some minutes inactive sessions and locks are automatically removed by PLA   The PLA setup is Windows compliant  Restricted Users are able to work with PLA  Deeper Details  about the Setup are found in the Setup Basics section of this manual  PLA can be installed in Terminal  Server environments     IT Administration Guide    127    PLA Setup Basics    PLA is Microsoft Windows Compliant         No write permission in the  Program Files  are required        PLA requires write permissions in the All Users Application Data        PLA requires write permissions in the My files section of an user       PLA requires write permissions to the Import Export Module path if you want to save Import  Definition Schemes  During installation administrative permissions are required   PLA should be installed on the local hard drive  It is not recommended to install PLA on network  drives  But you might point the report templates directory of PLA  the import export directories 
87. og  This dialog can be opened from the  login screen by pressing License Information     The License Management Dialog appears     IT Administration Guide    137    Press  Download License Keys  if you have an internet connection or type in the license keys you have  received with your license   Note  The License Keys match the hardlock id  If your License Keys are marked as invalid  check that  your hardlock id matches the keys      139    Reference    User Interface Reference    Account Management    The Account Management dialog allows you to create new user accounts and to modify or delete  existing ones      Defined Accounts    A list of existent accounts   Selecting an account allows you to delete or modify it     Add    Create a new account     Modify    Modify the selected account     Delete    Delete the selected account     PLA 2 0 User Manuals    140    Account Name    Allows you to enter or modify the name of the account  Each account requires a unique name     Account Password    When creating a new account or modifying an existing one you can set its password by typing it into  the corresponding field and retyping it in the field below  Remember that passwords are case   sensitive     Change password at next login    When creating a new account or modifying an existing one and enabling this option  the user defined  by this account is forced to change his password at his next login     User Groups    Each account is member of one group  A group defines the right
88. ommunicate these settings is to export the variable using REGEDIT and import  the setting by double clicking the  REG File created by the export     PLA 2 0 User Manuals    136    PLA License Management    Since PLA is a special application for a very small market  PLA is secured by a license management   This license management distiguishes between the trial mode and retail mode of PLA     Retail Mode    In Retail Mode PLA is delivered either with a desktop hardlock or with a network hardlock  depending  on the license you purchased     Seat License    The hardlock has to be connected to the local parallel port or USB port  PLA Setup      Concurrent Use License    This type of License is shared across the network  It is also necessary if you want to use PLA on a  Terminal Server Solution  The concurrent use license model requires a license in the network which  can be a normal workstation  if it is assured  that the workstation is switched on during your business  hours  Connect the Hardlock Server to the USB of the computer  that will serve as a license server and  install the hardlock server Software from the installation CD   The hardlock server manages the number of license you purchased  If the number of users exceed  the license limit  the connecting will receive a message to try again later     License Numbers    In addition to the hardlock you have received a set of two or three license numbers  They have to be  typed in  or downloaded  in the License Management Dial
89. omplete  The  certificate error report is created in the standard output directory  The certificate can be launched by  clicking on the hyperlink  that is available after the process finished   Note  If you want to check the PQ with its documentation you can toggle the cleanup switch     If you deactivated it  you can verify all the objects and calculation results after the PQ process has  been finished      125    IT Administration Guide    Welcome to the PLA IT Administration Guide    This guide is intended for those who are responsible to setup PLA in their environments  You will find  all necessary information to setup PLA and you will find all information regarding administrative  procedures   Note  This guide requires basic knowledge of operating system administration   Structure of this Guide        Description of for IT Professionals       PLA Setup Basics       PLA in Networked Environments       Terminal Server Recommendations       PLA Database Guide       PLA License Management       PLA User Management    PLA 2 0 User Manuals    126    Description of PLA for IT Professionals    PLA is a standard application for parallel line analysis of biological assays  It is used by laboratory  personal and scientist as well as in development of assays  tests  and in the application of these tests  in quality control units   PLA organizes the data of interest  assay data  in databases  The user can connect to different  database systems  In general file based databases  Micros
90. onse  You can force the optimizer to prefer or to mandatory  include the 50  value     Calculate 50   response by  The 50  response has to be discovered from the assay   To do so  you can use       the object itself       the standard       the control or       all objects of the assay     Figure  Screen Layout of the Configuration Properties    PLA 2 0 User Manuals    78     User Guide    79    Documentation Properties    The Documentation features allow to enter meta information for the assay  Each entry has several  properties   Property  Description    Documentation and Variables  Operators  Define the operators of the assay and their roles        Name       Role       Timestamp       Comments    Reagents  Define details of reagents used with this assay        Identification       Lot or Batch No        Concentration Amount       Comments    Equipment  Equipment used for this assay       Identification       Machine Lot No        Comments    Annotations  Remarks of the operators       Username       Timestamp       Annotation    User Variables  Key Value pairs available for reporting       Variable Name  Key        Value    Combination  Groups  Combination of assay results are calculated in groups       Combination Group    Figure  Screen Layout of the Documentation Features    PLA 2 0 User Manuals    80     User Guide    81    GxP Settings    The GxP settings allow the protection of properties   Property  Description    Default Template for Child Objects  Template  Selec
91. optimal way to copy  to and from spreadsheet applications such as Microsoft Excel  tm      User Guide    39    Audit Trail Page    The Audit Trail tab page of the editor shows every modification made to the object definitions     The audit trail consist of two sections        the upper section contains information on the applied action  In the sample the object has  been modified by PLA Administrator on 2006 08 14        the lower section displays the modification details of the action  In the sample  three values  are saved  The most interesting is the manipulation of the Response value in Series 1  step 1     PLA 2 0 User Manuals    40    Inheritance  Templates and the Apply Function    Inheritance    Inheritance of Object Properties    The understanding of object inheritance is necessary to make efficient use of PLA  The concept of  object inheritance is derived from the fact that in during normal course of laboratory life you will be  analyzing many assay of the same type  To reduce input effort and errors PLA has many useful  options to initialize new elements of your assay with correct properties   Assays with identical properties can be kept together in a single project  You can define the initial  values of new assays in the projects properties  If you now create a new assay within this project  All  properties of the new assay are inherited from the project  You do not have to input any properties if  these properties match your needs  Now you can create the third le
92. or written  permission  Products derived from this software may not be called  Apache   nor may  Apache   appear in their name  without prior written permission of the Apache Software Foundation  For written  permission  please contact apache apache org   PLA 2 0 uses libraries that are subject to the Lesser GNU Public License  LGPL  Version 2 1  the   License    you may not use these files except in compliance with the License  A copy of the License is  distributed in the same folder as the respective file  Software distributed under the License is  distributed on an  AS IS  basis  WITHOUT WARRANTY OF ANY KIND  either express or implied  See  the License for the specific language governing rights and limitations under the License  All rights  reserved      187    Licensing Agreement    for products of  Stegmann Systems  Stegmann Systemberatung   Raiffeisenstr  2  63110 Rodgau  Germany  All products sold by Stegmann Systems or companies associated therewith  including demonstration  sets  hardware  media and manuals  hereinafter referred to collectively as  Product   as well as all  future orders shall be subject to the following provisions  If you do not accept these provisions  please  return the product to us within seven  7  days of having purchased or received the Product  We will  refund the purchase price minus fees for ship ping and processing   1  License  Stegmann Systems holds all rights to the Product and herewith assigns to you a nontransferable   nonexclusive ri
93. oughly checked the corresponding Complete Statistics  Report  you can use the PQ to perform the Performance Qualification using the Performance  Qualification Wizard     Validation Guide    121    Preparing the Performance Qualification    As a prerequisite you need to define your comparison data in PLA in any project  This project may  contain any number of assays you want to include in your PQ data set  When finished  start the  Performance Qualification Preparation Wizard from the Validation menu by selecting  Create a PQ  dataset   The following wizard appears     Now select the input object by pressing the button next to the corresponding input field and select  your PQ project from the list     Then select the filename of your PQ file  Press start to start the generation  The wizard now creates  two files        the PQ file and       the corresponding Complete Statistics Report  The Complete Statistics Report is located in the same directory as the PQ file   Now you have to check the report for correctness  Once you have accepted the results  you can  proceed to the Performance Qualification task     PLA 2 0 User Manuals    122     Validation Guide    123    Performing the Performance Qualification    From the Validation Menu select Performance Qualification  PQ   The following dialog appears     Select your PQ file using the button near the input field  Press Start to start the PQ Process   Depending on the size of your PQ file the process may need several minutes to c
94. ous kinds of meta data for your assays       GxP Options  allow to protect groups of properties from manipulation    User Guide    69    General Properties    General properties describe management information for an object   Property  Description    Name and Description  Name  Name of the object with up to 50 characters    Description  Detailed Description of the object  Up to 255 characters     Standard Preparation  selector  allows to switch the object types of standards and preparations    hide in navigator  hide the object from the navigator and from calculation    Measurement Details  Substance  The measured substance whose potency shall be calculated    Optional     Batch ID  Batch Identification of the measured substance  Optional     Timestamp  Date and time when the measurement has been done    Electronic Signatures  Electronic Signatures  Electronic Signatures that have been applied to the object     Figure  Screen Layout of the General Properties    PLA 2 0 User Manuals    70     User Guide    71    Dose Properties    Dose properties describe the way an standard or preparation is prepared for analysis  They allow the  definition of raw material or stock solution potencies  If defined  PLA calculates the potency factors for  these potencies   Property  Description    Raw Material  Raw Material  A raw material   bulk substance potency will be given  The calculation  results will contain a potency estimation for the raw material    Assigned Assumed  Potency  The pote
95. out your PLA Installation   See also  Product Information    PLA 2 0 User Manuals    158    License Management     License Status    The status of your PLA installation and the Hardlock status     License Details    A list of Licenses with their status     License Key    Text edit field for entering a license key manually     Add    After having entered a license key into the License Key field  click this button to add the license     Download License Keys    If you have an Upgrade Protection for PLA 2 0 you ll be able to download your license keys directly  from our license server   Note  This feature requires an internet connection     Reference    159    Inquiry Key    This key is generated by the PLA Licensing system  It is required if you need to get an extension of  your trial period   Note  This feature applies only to the Trial Mode of PLA     Submit Online    Submit your Inquiry Key online  This will open the PLA License Inquire page in your internet browser   You can use the form on this page to submit the query   Note  This feature requires an internet connection     Submit by E mail    Submit your Inquiry Key by e mail  This will open you mail application with a prepared mail containing  the required information for a new trial key  You d just have to press the  send  button   Note  This feature requires an internet connection     Vendor Response    Once you have received the response code from PLA support  you d have to enter it into the green  text field     OK 
96. paration or control within an existing assay  select  the assay or any of its child objects   Once you have selected  Create Objects  the following dialog displays     This dialog has three areas   1  Select an object type  There are several entries that allow to create different objects  This  list depends on the neighborhood stated above  In the figure you have the option to create  four different object types  The selected option is a preparation that will be a child of the  assay  Assay 2    2  In the second section you have to input the name and a description of the new object   This is mandatory   3  In the third section you may want select a template  If you don t select a template the  standard inheritance is used     PLA 2 0 User Manuals    30    Once you press Create the new object is created  You will receive the following message which  indicates  which object served as a template     In our case standard inheritance has been used and the object settings are initialized with the values  of  Assay 2      User Guide    31    Copying and Moving of Objects    Objects can be copied and moved between different parents  If you copy an object the new object is  completely new initialized with the values of its source  The audit trail starts with a create object  entry  If you move an object  only the parent link is refreshed   If you use electronic signatures there are some restrictions        It is not allowed to copy or move objects into signed assays        It is not a
97. password is stored in an encrypted form and can not be discovered by common  means   Note  This is only applicable for SQL Server authentication mode     Blank Password    This option should be disabled if you choose SQL Server Authentication because it would be careless  to use an SQL Server account without password   Note  This is only applicable for SQL Server authentication mode     Save Password    This option must be enabled in order to create a complete PLA database connection profile   Note  This is only applicable for SQL Server authentication mode     Select the Database    Enter the name of the PLA database  e g  My PLA Database  or select the database from the database  list   Contact your database administrator if you are not sure about the database   Note   The database must already exist on the server and the provided user must have the rights to create   erase and modify database objects  Contact your database administrator for further information     Test Connection    Click here to test the connection to your SQL Server   If  for any reason  the test fails contact your database administrator for further guidance     Reference    155    File Menu    This topic describes the File Menu of the PLA menu bar      Navigator    Show or hide the Navigator     Create Object    Create a new object   See also  Create Object Dialog    Edit Object    Edit the selected object s properties and definitions   See also  Introduction to Object Properties    Save Object    Save 
98. port    PLAs External Data Formats    The Import Export methods of PLA directly support three file formats     PLA Secure Format  PSF     The PLA Secure Format is the preferred external data format of PLA  The format is digitally signed by  PLA s internal PKI  This prevents the format from any manipulation and thus allows to securely  transfer even electronic signatures from one PLA installation to another   The digital signature of a PSF file is checked on every import  If the signature is invalid  the PSF is not  imported     PLA External Format  PEF     The PLA External Format has the same structure as the PLA Secure Format  PSF   but it is not digitally  signed  Therefore  no electronic signatures are imported from PEF files and they are not secured  against manipulation     PLA Native Format  PNF     The PLA Native Format  PNF  is the PLA 1 2 compatible data format  It is delivered for compatibility  reasons  The PNF format only excepts PLA 1 2 settings and is therefor not intended as an external PLA  2 x format     User Guide    49    Import    PLA is fitted with a strong import wizard that allows the importation of external data into PLA  One  can distinguish three types of import        Import of PLA s External Data Format       Import of External Data using PLA Import Modules       Import of External Raw Data using PLA Import Modules  The first two import types follow the standard path  while the latter type follows the raw data path   See following chapters      PLA
99. preparation  control  and its dimension  number of replicates and treatments   Remember  to press  Apply  to activate your settings after modification     PLA 2 0 User Manuals    58    When the assay dimensions are correct  press Next gt  to continue     Bind the Raw Data to your Assay    Now you have to bind the raw data to your assay  The Import Wizard has several options to display  your data   Grid Display Options  By default the raw data is displayed in 12 columns  This leads to a correct display of a 96 well plate if  you have 96 response values   You have the option  to display the data point number and the response value itself  You may also  switch the default display of the grid  if standard data display is different     User Guide    59    Assign the Raw Response Values  The next step is to assign the required values to a standard  preparation and control and to assign it  to the corresponding dilution step  The dilution step value is assigned by the template  the parent  object or later when you edit the object  In a 1 in 2 dilution series  the first step has the highest  concentration   Select the data point in the grid and then select the object and dilution step in the  Selected  Datapoint  section   In the following picture the response value in column 1 and row 1 is assigned to the standards first  dilution step     PLA 2 0 User Manuals    60    The data grid is automatically colored  if this activated in the grid display options   The data point is  now disp
100. responsible for installing PLA in your environment and set up central database  services      PLA 2 0 IT Administration Guide  Find information for the IT administration of PLA      PLA 2 0 Validation Guide  Find out how to validate PLA using the PLA Validation Package      5    Getting Support    There are several ways to get support  Do not hesitate to make use of the available help options     Websites    For Product Information  www bioassay de  Our Electronic Customer Feedback System  error reports  feature requests    support stegmannsystems com    E Mail    E Mail to support bioassay de for any questions and comments     Phone    During business hours  7 30 a m    6 30 p m  GMT   English  and German  phone support is available   49 6106 77010 0    Fax     49 6106 77010 29     7    Getting Started    Parallel Line and Parallel Logistics Assays    Biological or potency assays are frequently analyzed with the help of the parallel line or parallel   logistics  4  or 5  parameter fit  methods  These methods have major advantages over traditional  single point assays        The linear or sigmoid dose response correlation is not only assumed but confirmed in each  calculation        The dose response curves of the standard and sample preparations are confirmed to be  parallel  Whereas in single point analysis parallelism is a necessary requirement too  but  cannot be proven        A dose independent potency in terms of the standard   s potency is calculated for each assay   a
101. rlink on the Login Dialog     Close    Closes this dialog  You will be asked again to register upon next startup     Reference    171    Session  amp  Lock Management    This dialog allows you to manage all active sessions of a PLA database and their corresponding locks      Sessions    A list of active sessions     Locked Objects    A list of locked objects of the currently selected session     Autorefresh lists    If checked  both lists will refresh automatically     Refresh    Click this button to refresh both lists manually     Reset Sessions    PLA 2 0 User Manuals    172    Removes outdated sessions from the PLA databases  No active sessions are touched   Note  PLA removes outdated sessions automatically  Usually there is no need to manually remove  them     Kill Session    Kill the selected session  The session is deleted and all locks of this session are removed  This is useful  if there is an invalid session entry which hold locks on objects   Note  Use this option with caution  Invalid session entries are removed automatically after two hours     Unlock    Remove the selected lock     Close    Close this dialog     Reference    173    System Menu    This topic describes the System Menu of the PLA menu bar      Options    Open the Options Dialog to modify the configuration of PLA   See also  Options Dialog    Account Management    This options allows you to manage the PLA user Accounts   See also  Account Management    Change your Password    This option allows you t
102. rms of License    The next step is the acceptance of the Terms of License  This is required to install PLA     Getting Started    9    Once you select  I accept the terms in the license agreement  the Next gt  button is enabled  Select   Next  gt      Select Destination Folder    By default  PLA is installed in the  Program Files  folder of your computer system  This screen allows  you to select a different destination folder if you need to      PLA 2 0 User Manuals    10    Press  Next  gt   to continue     Start the Installation    Click  Install  to start the installation procedure  The setup program starts the installation sequence     When the installation process is completed press Finish to close the installation dialog     Getting Started    11    If you have received a Software License Module  HardLock  with your retail package  attach it to your  system  PLA is completely installed now   Where to go from here        Basic Database Management       Basic Concepts of PLA 2 0       Basic of PLA 2 0 Mathematical Features    PLA 2 0 User Manuals    12    Attach the Software Licensing Module  Hardlock     If you need to attach a Software Licensing Module  Hardlock  to your system   you should install the PLA 2 0 software first  to have the necessary device drivers available     Install Parallel Port or Serial Port Hardlock         Attach the Software Licensing Module  Hardlock  to your  computer system   If a printer is attached to your computer than detach the printer ca
103. s  an account has within the PLA  system  The currently assigned group is highlighted  You might assign the current account to another  group simply by selecting it in the list of groups   Description of the PLA groups        Administrators   Administrators have full access rights   They modify GxP   SOP Settings and manage accounts        Standard Users   This is a regular working account   Access rights are limited through the GxP   SOP Settings defined by an Administrator        System Inspectors   Accounts assigned to this group have read only access   They are allowed to view all objects  but not to modify them        Deactivated Users   Existing accounts  that are  temporarily  deactivated   Users having deactivated accounts cannot log in     Save    Save the newly created or modified account      Cancel    Cancel the creation or modification of an account and discard all changes     Close    Reference    141    Close the Account Management dialog     PLA 2 0 User Manuals    142    Action Menu    This topic describes PLA s Action Menu      Calculate  amp  Report    Opens the Calculate  amp  Report Dialog which allows you to start the calculation process and create  reports     Data Explorer  Check     Opens the Data Explorer  Check Dialog  which shows you a graphical overview of your assay and  preliminary calculation results  See how to Explore your Assay     Combination of Assay Results Editor    Opens the Combination of Assay Results Dialog  which allows you to defin
104. se information are  displayed by clicking the respective buttons on the lower right   After you have successfully logged in  the PLA main screen is displayed     User Guide    23    Screen Layout    The following figure shows the basic screen layout of PLA     The screen consists of the following areas        menu section  This is a classic windows menu system  The file menu contains commands management  commands for the database objects  files   the action menu contains the commands for the  analysis of assays  the system menu contains all the system options for PLA  The validation  menu allows you to performance the installation  operational and performance qualification  tasks  the window menu contains commands for organising the sheet windows  In the help  section this online help and product and license information is found        toolbar section  The toolbar section contains the most frequently used commands within PLA  They are  activated and inactivated in correspondence to the selected objects in the navigator        navigator  The navigator is displayed left to the sheet area  It allows you to manage and navigate  through your selected database        sheet area  Once you open an object for editing of for analysis it is open in the dark grey sheet area  This  area is a multiple document interface  MDI   allowing you to use multiple objects at once        The information line  On the bottom of the window  the information line displays the connected database  in the  
105. sh the list from the database     Close    Close this dialog     PLA 2 0 User Manuals    146    Change your Password    This dialog allows you to change your password      User Name    Your user name  account name  is displayed here     Current Password    Enter your current password into this field     New Password    Enter your desired new password into this field     Retype New Password    Reenter your new password in this field     Change Password    Clicking this button changes your password     Cancel    Clicking this button cancels changing your password and closes this dialog     Reference    147    Context Menu    This topic describes the Context Menu of the PLA Navigator       Create Object    Create a new object   See also  Create Object Dialog    Edit Object    Edit the selected object s properties and definitions   See also  The Editor    Copy    Copy the selected object   See also  Copying and Moving of Objects    Move    Move the selected object   See also  Copying and Moving of Objects    PLA 2 0 User Manuals    148    Delete    Delete the selected objects and all of it s child objects     Apply    Apply a template or project definitions to the selected object   See also  Apply Dialog    Lock Tree    Lock the selected object and all of it s descendants   See also  Locking Objects    Unlock Tree    Unlock the selected object and all of it s descendants   See also  Locking Objects    Import    Open the import wizard to import data into PLA   See also  Import    
106. significance of the lack of fit  values     ANOVA based on Residual Error    This is the classical approach based on the regression model  In principle  the analysis of variance  considers the regression model and deviations from the regression model as sources of variation  The  lack of fit gets part of the error term  so there is no separate test of linearity with this approach  This  approach is available with one or more replicates     Hypothesis tests base on separate ANOVAs    PLA 2 0 User Manuals    20    This is the PLA 1 x compatible approach  For each hypothesis  separate regressions are carried out  and the individual ANOVAs are calculated  The linearity is tested as the significance of a quadratic  term     Test of Parallelism    PLA has three different tests for parallelism available  The  classical  test is the F Test for the  insignificance of parallelism carried out as a difference of models test  Especially assay with low  variability often fail this test  A new approach is the equivalence test  which tests the ratio of slopes or  difference of slopes of the standard and the preparation against predefined constants  goalposts      Configuration Optimization    The configuration of an assay in terms of PLA is the selection of individual treatments of the standard  and the preparation for analysis  While in Parallel Logistics Assays the whole dose response curve is  taken into consideration Parallel Line Assays focus the linear portion of the dose response curv
107. splayed as tab pages in the editor        General Properties  describe general aspects of the edited object  The name of the object  the create and  modification timestamps and the substance details are part of this group   In addition the latest calculation results of the object are displayed   These results will be  deleted when the object properties are changed         Dose Properties  This set of properties defines the preparation steps of an object  The settings also define  which potency calculation shall take place in which way        Data  Response  Properties  This page allows to define the dimension of the data set used for analysis  Data input takes  place on this page       Analysis Properties  This page take the various analysis properties        Configuration Properties  The configuration properties allow the manual or automatic detection of the regions of  interest within your treatments        Documentation Properties  You can add various documentation entries to the object definitions  such as reagents used   operators  equipment  This is added on the documentation page        GxP Settings  On the last property page you are allowed to define the GxP settings you want to make use of  to add input security to your objects     User Guide    37    Data Input    Data Input is available on the data tab page of the object editor dialog   The input of response values is only available on the data tab pages of the respective objects   standard  preparations and contro
108. standard import  After you selected your file type and the input file the analysis  section of the Import Wizard might contain the following information     Especially note the remark  There is raw data present   This raw data has to assigned to the required  objects in PLA   Now press Next gt  to start the import process     Load Import Definition Scheme    First of all you might load a previously saved import definition scheme  IDS   An IDS allows you to  save all the steps of the following pages and to efficiently load external data  In our case no scheme is  available yet  We will save our settings after we have defined everything     PLA 2 0 User Manuals    56    Press Next gt  to proceed     Selection of Target Project and Templates    In this step you define the target of the operation  select a project or create a new one  and you have  the option to select a defined template for the objects the import process will create  By doing so you  are able to predefine all object properties of the new objects     User Guide    57    Press Next gt  to continue     Define Assay Dimensions    Now you have to define the number of target objects  standard  preparations  controls  for the assay  you will create  Define the number of objects and press  Apply general settings    The list of raw data objects now contains the desired number of objects  You edit each one  by  selecting it  In the lower section  Object Details  you can modify the code of the object  its type   standard  
109. supported   The corresponding OLE DB Provider for Microsoft SQL Server is selected automatically   For detailed information how to set up a PLA database on a Microsoft SQL Server please refer to PLA  Databases      Server Name    Enter the name of your database server here  e g   MyServer   If you have multiple instances of an  Microsoft SQL Server you need to enter the name of the server and the named instance separated by  a backslash  e g  MyServer MyInstance   You can also select one of the SQL Servers in the server list   Contact your database administrator if you are not sure about the SQL Server to be used     Refresh    Click here to refresh the list of SQL Servers     User Authentication Mode    Select between Windows authentication and SQL Server Authentication  If you choose SQL Server  Authentication be sure to have a user name and a password on hand  It is recommended to use SQL  Server Authentication and to create a  PLA user  just for connections of the PLA system to the PLA    PLA 2 0 User Manuals    154    database  The password of the  PLA user  is kept in confidence and only encrypted connection  profiles are distributed   Contact your database administrator if you are not sure about the authentication mode     User Name    Enter your SQL Server user name here   Note  This is only applicable for SQL Server authentication mode     Password    Enter your SQL Server user password here  This information is required if you choose SQL Server  Authentication  The 
110. t       Grubb s Test       Test based on standard deviation  These tests analyze each treatment group separately  They check the extreme value for statistical  significance and remove it  Optionally these tests can be executed iterative   An alternative approach is realized with the        Externally  Studentized Residuals Test  This test checks the influence of an potential outlier on the regression results  If the influence of the  outlier is significant  it is removed from analysis   Note  This test may require significant amounts of  additional computational time      Analysis of Variance  ANOVA     PLA has different variants of ANOVAs for hypothesis testing available  They are augmented by  equivalence tests to achieve tests for parallelism   The basic hypothesis tests are        Test for the significance of the Regression       Test for the insignificance of deviations from linearity       Test for the insignificance of deviations from parallelism    ANOVA based on Pure Error Separation    This is the preferred approach in PLA 2 0  This ANOVA separates the influence of the treatments from  the pure error  The pure error is the error that is obtained by summing the error squares of the  deviations of the replicate response values from the treatment means  This value is a direct  measurement of the dispersion of the measurement system  This method is available if you have at  least two replicates   The model allows calculating significant deviations from the model as the 
111. t a template to be used as a template when childs are created     GLP SOP Protection Level Settings  Enable GxP SOP  protection   Mandatory     Available for administrators only  Activates the protection     Enable GxP SOP  protection  User  Level     Available for every user  when the above property is inactive   Activates the protection     Protection Level  Substance  Information  protects informations on the subject  but not the Batch Identification     Documentation  protects the documentation properties    Dose Definitions  protects the dose properties    Analysis  protects the analysis properties    Configuration  protects the configuration properties    Dose Values  protects the dose values dilution series    Response Values  protects the response values  useful only in combination with PLA  Import Modules     Keys and  Combination  Groups    protect user defined variables     Figure  Screen Layout of the GxP Settings    PLA 2 0 User Manuals    82     User Guide    83    Analyze Assays    Introduction to Assay Analysis with PLA    Assay analysis with PLA is easy  Once you have defined your assay  and keyed in the appropriate  response values PLA is full suited with every tool you need for fast and efficient analysis   One has to distinguish between the tools and the analytical options of PLA  The Assay Explorer of PLA  is suited with all options for a deeper graphical analysis  The Assay Explorer gives you the option to  check your assay  With a full range of graphica
112. ted but you will be connected to this  database   After you created a new database the new database appears in the list of defined connection profiles   Select it and click open database to connect to it  You are immediately asked for an administrator  password for the first administrator of this database     IT Administration Guide    133    Type in a password  Note  The password cannot be recovered if you loose it     Create A SQL Database  Connection     This section requires basic knowledge on database administration   The first step has to be done by your database administrator  He has to create a new empty database  and he has to define a user id that has to be able to create tables and indices within this database   DB Owner permissions   Once this is finished you can go ahead with PLA   Open the Database Management as describes above  then select Connect a Database Server  A  standard dialog of the operating system appears that allows to input the connection data for the new  database  Select your server and database and type in the userid and password you created on the  database server  Then press ok   Open the database  If this is the first time the database is opened by PLA  you are asked to create the  tables and indices PLA requires  The following dialog appears     Select Yes to create the tables  After the tables are created  you are asked for an initial PLA  Administrator password as seen above     Remove Database Connections    PLA 2 0 User Manuals    134   
113. to thoroughly select the valid dose response regions for the  assay  You can do this by selecting a fixed range on the configuration page of each object  But you  can also let PLA do the work for you   If you decide to try the automatic optimization you should nevertheless thoroughly check results   We will try the following   PLA should search for a maximal region in the assay  that fulfills the hypothesis criteria  The 50   response of the assay should be included  The optimized solution should have identical number of  points  treatments  for both  Standard and Preparation   So we go to the Configuration page of the assay  since we activated the inheritance option  If we  didn t  the next steps have to executed on the standard and the preparation    Now we select the options as follows     Once we have saved the assay  we select  Check  from the toolbar again  The assay explorer re   appears with the following screen     PLA 2 0 User Manuals    108    The assay now passes all hypothesis tests and the visual inspection displays a solution in accordance  to our expectations  The Potency ratio is calculated as 0 54 with a confidence interval of 0 485 to  0 602  Now lets switch to full curve fitting with the 5 parameter method and lets have how this solution is  calculated     My First Assay with PLA    109    Switching the Regression Model to 5 Parameter Logistics    The 5 parameter logistics functions is used very often nowadays  since it allows to take the full curve  into 
114. torial we will make use of this starting at the assay level  If we had to analyze many  assays of this type  we could use the properties of the project to have defaults for all objects   To reach best efficiency we will create the project  without defining anything  Then we will add an  assay and define our initial properties  The last step is the creation of the standard and the  preparation  We will then add data to both of them   In the navigator the sample will look like this      My First Assay with PLA    101    Data Input    Follow these steps to create the sample assay     Create the Project    Select  Create Object     from the File menu  The Create Object Dialog appears     Now Select  New Project  as the object type  Then type in  Sample Project  as the name and  Sample  Project for the Tutorial  as description  Press Create to create the object  The next message  acknowledges the object creation     After pressing ok  the Editor for the project appears  Close it by clicking on cross at the right edge of  sub window     Create The Assay    PLA 2 0 User Manuals    102    Now create the assay by selecting the parent project in the navigator  with a single left click   Then  select  Create Object     from the file menu  the context menu or the toolbar  Select  New Assay as  Member of Project  Sample Project   as the object type   Once the object is created  we will set the initial parameters of the objects   Three groups of information have to be set   1  The Assay Di
115. u bar      Installation Qualification    Opens the Installation Qualification  IQ  Dialog   See also  Installation Qualification    Operational Qualification    Opens the Operational Qualification  OQ  Dialog   See also  Operational Qualification    Performance Qualification    Opens the Performance Qualification  PQ  Dialog   See also  Performance Qualification    Create a PQ Dataset    Opens a dialog allowing you to create a PQ Dataset which can be used to perform the PQ on antoher  machine running PLA   See also  Performance Qualification    Reference    177    Window Menu    This topic describes the Window Menu of the PLA menu bar  It allows you to arrange your windows in  PLA      Cascade    Cascade all open windows     Tile Horizontal    Tile the view horizontally     Tile Vertical    Tile the view vertically     Layer    Layer all open windows above each other     Minimize All Windows    Minimize All Open Windows     Undo    Rest the the last set alignment and reset the windows to their previous view      179    PLA 2 0 vs  PLA 1 2    PLA 2 0 is the successor of the leading PLA 1 2 System  PLA 2 0 has been re coded in many sections   The system design has been refreshed and a variety of options have been added   If you are currently using PLA 1 2 the following notes may be relevant for you     No Interaction of PLA 1 2 and PLA 2 0    You may install and use PLA 1 2 and PLA 2 0 on the same computer system without any restrictions   Both versions do not influence each ot
116. vel objects of your assay  Anything  you need to enter are object names and the response values of your measurement   IMPORTANT  If you change properties of parent objects these changes do not influence the child  objects if you did not bind the child objects to the parent explicitly  available on the third level only    If you want to deploy new settings to child objects you can make use of the Apply functionality of  PLA   Beside this approach of inheritance there more advanced concepts of templates  GxP and SOP  support  These approaches are described in detail in the user manual     How Are the Initial Properties of an Object Set     There are three variants how initial properties can be set   1  Use of a Template  A template is used when        the administrator set a mandatory default template in the Global Options       the parent project has a template connection  page GxP of the editor      User Guide    41         the user choose a template in section 3 of the Create dialog     2  Inheritance    PLA 2 0 User Manuals    42    If no template is used all properties are inherited from the parent object   3  Default Values  Default values are used when no template is used and no parent is available  This is possible for  Projects only   After an object is a created  a message appears notifying you about the used set of initial parameters      User Guide    43    Templates    Templates are standard PLA objects used to create new objects  PLA differentiates two types of  t
117. xpire until the minimum age is reached   2  By setting this option to 0 you disable it   3     Possible Values 0   n  Default value  0    10       Password age expiry blocks  1  If this option is set to true  a user account is blocked if its password is  expired  Otherwise the user will be asked to change an expired password  upon next login   2     Possible Values false  true  Default value  false  11   12    Password maximum failures  1  This option defines the number of failed login attempts until the  corresponding account is blocked  Setting this value to 0 disables this feature   2     Possible Values 0   n  Default value  0  13   14    Password failure grace interval  1  This option defines how long  in minutes  an account will be blocked if the  number of login attempts exceed the maximum number of password failures   Setting this value to 0 means forever   2     PLA 2 0 User Manuals    166    Possible Values 0   n  Default value  0  15   16    Password history length  1  This options specifies the password history length  PLA stores a list of the  specified length of old passwords for each account  A new password will be  rejected if it matches an entry of the list   2  Specifying 0 will set the password history length to unlimited  meaning that a  new password must not match any password which has been used earlier by  this account   3     Possible Values 0   n  Default value  0    17       Password list of invalid passwords  1  A list of passwords which must not be
118. y estimation    Fieller s Theorem  use Fieller s Theorem instead of the standard confidence interval   requires linear regression     EC50 Method  EC50 Method  Which regression is to be used for the EC50 calculation    Response 50  Calculation  How is the response 50 calculated    Figure  Screen Layout of the Analysis Properties    PLA 2 0 User Manuals    76     User Guide    77    Configuration Properties    The configuration properties define the settings for the configuration optimization   Property  Description    Linear Range Configuration  Method  Select the optimization method        Full Range       Fixed Range       Automatic Detection  individual        Automatic Detection  common range for the  standard  individual for preparations        Automatic Detection  common range for the  standard  identical for preparations        Automatic Detection  individual range for the  standard  identical for preparations     Fixed Range  To   From  Step number of the selected range    Automatic Selection Options  Allocation  Strategy  The optimization fits the        best range       maximum range       exact range    Minimal Exact    of points  Allocated configurations have at least exact this number of  steps    Allocation Region  is either the full range or a defined subrange    select only  configurations  with identical  number of  treatments    Allows to force the optimizer to select only identical  number of steps in both  standard and preparation     Include the 50   resp
    