1. IDENTIFICATION select by pressing the Confirmation Enter key Sine system information will be displayed INFORMATION gt IDENTIFICATION EVENTS LOG CONFIGURATION IDENTIFICATION Model Humber serial Number Margai Fated Voltage Rated Current HA Phase Frequency Ln 26 User Manual for UN ARTECHE LCD Control amp Monitor Panel POWER QUALITY 3 In the IDENTIFICATION menu screen use the Up or Down key to view Sine Program Version LCD Panel Program Version and ID address number IDENTIFICATION StacoSine Program Ver LCD Panel Pregram Yer ID 27 User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO DISPLAY EVENTS LOG Scroll to INFORMATION select by pressing the Conformation Enter key Date 2008 08 10 Running gt gt gt gt Time 08 30 00 LoAD RATE gt Information Meter Control 2 In the INFORMATION menu screen scroll to EVENTS LOG select by pressing the Confirmation Enter key The events log will be displayed Use Up or Down key to browse the events The log capacity is 300 lines with FIFO First In amp First Out principle INFORMATION IDENTIFICATION gt EVENTS LOG CONFIGURATION EVENTS LOG 014 2004 07 01 10 49 20 CODE A004 A gt System under voltage NO 013 2004 07 01 10 19 19 CODE A004 A gt System under voltage YES 012 2004 07 01 10 19 1
2. and select by pressing the Confirmation Enter Key PARAMETER WAVEFORM gt SPECTRUM 3 In this menu use the Directional Scrolling Key Pads amp Confirmation Enter Key to select the desire spectrum parameters you wish to view The first screen will display the spectrum for 1 to 15 harmonics order SPECTRUM Vab gt la L la S la E Vbe Ib L Ib S Vca Ic L COR 10 User Manual for CN ARTECHE LCD Control amp Monitor Panel Y Y POWER QUALITY 4 In the SPECTRUM VIEW screen use the Left or Right key to view the THD of each respective harmonic order VIEW tait HOS 224 THE aq Freq 60 0 Hz 5 Use the Up or Down key to display the spectrum for the 17th to 31st order harmonics VIEW la L Represents the electrical parameter presently selected to view the spectrum Example the above screen displays the spectrum for A phase current la L at load side H21 0 3 The 21st harmonic order is 0 3 of the fundamental value 1 harmonic order THD 32 4 Total Harmonics Distortion is 32 4 Freq 60 0Hz Fundamental frequency is 60Hz 11 AN ARTECHE User Manual for N LCD Control amp Monitor Panel POWER QUALITY CONTROL MENU TO ACCES THE CONTROL MENU 1 Use the Up or Down key to scroll to CONTROL select by pressing the Confirmation Enter Key Date 2008 08 10 Running gt gt gt gt Time 10 15 00 LOAD RA
3. Meter gt Control 2 In the INFORMATION menu screen select CONFIGURATION by pressing the Confirmation Enter key Sine system configuration will be displayed INFORMATION IDENTIFICATION EVENTS LOG gt CONFIGURATION 30 AQ ARTECHE POWER QUALITY User Manual for LCD Control amp Monitor Panel CONFIGURATION Harmonie Compensation Higher order Compensation Harmonic Harmonic ord sth 7th h Harmonie h Harmenie ENABLE ENABLE DISABLE ENABLE ENABLE ENABLE ENABLE DISABLE DISABLE DISABLE DISABLE Inthe CONFIGURATION menu screen use the Up or Down key to view the Smart Save Energy Reactive Power Regulation and Application Mode settings CONFIGURATION Reactive Power Regulation Application Mode DISABLE DISABLE Note If you want to change the setting of CONFIGURATION please contact local authorized service agent 31 User Manual for A ARTECHE LCD Control amp Monitor Panel POWER QUALITY Technical support is available when you contact us any of these methods Office Phone 1 262 754 3883 Office Fax 1 262 754 3993 Email info artechepq com Website www artechepq com ARTECHE PQ INC 16964 West Victor Road New Berlin WI 53151 Phone 1 262 754 3883 Fax 1 262 754 3993 32
4. QUALITY P m E User Manual for A ARTECHE LCD Control amp Monitor Panel TO DISABLE FILTERING OF THE SINE 1 The screen will display STOP command when the system is providing filtering Follow the shut down procedures as described in section 3 and press Confirmation Enter Key to turn off the AHF CONTROL gt AHF STOP Panel Switch DISABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 2 Once the AHF is turn off successfully the screen will change to RUN and the Filtering Green LED indicator will turn off CONTROL gt AHF RUN Panel Switch DISABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 14 POWER QUALITY pe 5 User Manual for ARTECHE LCD Control amp Monitor Panel TO ENABLE ON OFF KEYPAD SWITCH ON FRONT PANEL 1 The screen will automatically display PANEL SWITCH ENABLE command when the ON OFF keypad switch on the front panel is not inhibited Press Confirmation Enter Key to enable the keypad switch CONTROL AHF STOP gt Panel Switch ENABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 2 The screen will change to PANEL SWITCH DISABLE command when the ON OFF keypad switch on the front panel is active CONTROL AHF STOP gt Panel Switch DISABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 15 POWER QUALITY User
5. 0 CODE S001 A gt Flitering NO 28 Pc User Manual for A ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO CLEAR EVENTS LOG 1 In the EVENTS LOG screen press the Confirmation Enter key to access the PASSWORD screen EVENTS LOG 014 2004 07 01 10 19 20 CODE A004 A gt System under voltage NO 013 2004 07 01 10 19 19 CODE A004 A gt System under voltage YES 012 2004 07 01 10 19 10 CODE S001 A gt Filtering NO 2 To enter the password use the Up or Down key to select from 0 9 for each digit and the Left or Right key to move from the 1 digit to the 4 digit Use the Confirmation Enter key to confirm the selected password Once password is accepted by the system the CAUTION will be displayed PASSWORD ENTER PASSWORD 0 CAUTION I Clear EVENTS LOG gt YES NO 29 User Manual for ARTECHE LCD Control amp Monitor Panel x Y POWER QUALITY 3 If you want to clear the events log use the Left or Right key to select YES then press the Confirmation Enter Key to confirm the action Go back the EVENTS LOG screen to confirm the log has been cleared EVENTS LOG 001 2004 07 01 10 20 20 CODE C012 EVENTS LOG CLEARED TO DISPLAY SINE CONFIGURATION 1 Scroll to INFORMATION select by pressing the Conformation Enter key Date 2008 08 10 Running gt gt gt gt Time 08 30 00 LOAD RATE Information
6. ARTECHE e POWER QUALITY User Manual LCD Control amp Monitor Panel For Type AHF Active Harmonic Filter 16964 West Victor Road New Berlin WI 53151 Phone 1 262 754 3883 Fax 1 262 754 3993 Web site www artechepq com December 15 2008 User Manual for LCD Control amp Monitor Panel CONTENTS LCD Control amp Display Panel Descriptions 2 Operating the Graphic LCD Monitor 4 Functional DCSCHDUONS A AK iei a eror o NG ENE daa euis sates Ka Ka dai desc hak 4 F nctional Elow Gath E E A eign Ga DHEK KA a ea ag 4 The Descriptions of Key Pads for Graphic LCD Monitor 5 TE semet rU LUE 6 7 OOM a eee TE 12 OA OMIS AR a 21 User Manual for AN ARTECHE LCD Control amp Monitor Panel POWER QUALITY LCD CONTROL amp DISPLAY PANEL DESCRIPTIONS The Control amp Display Panel is made up of 8 Control Keypads 4 LED indicators and 1 Graphic LCD which provide the following functions Turning ON OFF the AHF Clearing error status and silencing audible alarms Display all operating status 1 2 3 2084 07 02 HUNE nv ah mimi CONTROL ea 0 10 9 s 7 6 51 4 Display Screen Displays of measurements waveforms operation amp co
7. ENABLE DISABLE CONTROL gt PASSWORD DATE amp TIME SET LCD CONTRAST PASSWORD RELEASE DEMO ENABLE DISABLE User Manual for CN ARTECHE LCD Control amp Monitor Panel Y Y POWER QUALITY THE DESCRIPTIONS OF KEY PADS FOR GRAPHIC LCD MONITOR Directional Scrolling Key used to scroll the menu and input various parameters Zi Escape Key used to return to previous menu or cancel discard the parameters Confirmation Enter Key used to go to the next menu and confirm the selection or enter the desire parameters User Manual for CN ARTECHE LCD Control amp Monitor Panel Y Y POWER QUALITY MAIN MENU 1 2 Date 2008 08 10 Running gt gt gt gt Time 10 15 00 woua Information gt Meter Control 5 3 4 1 AHF Status RUNNING gt gt gt gt AHF is filtering STOP AHF is shut down 2 The current date amp time 3 Load Rate Bar Graphic 4 Main Menu 5 Cursor Use the Up or Down key to move the cursor User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY METER MENU TO VIEW ELECTRICAL PARAMETERS 1 Use the Up or Down key to scroll to METER select by pressing the Confirmation Enter Key Date 2008 08 10 Running gt gt gt gt Time 10 15 00 LoAD RATE Information gt Meter Control 2 Once inside the METER menu scroll to PARAMETER select by pres
8. Manual for ARTECHE LCD Control amp Monitor Panel TO DISABLE ON OFF KEYPAD SWITCH ON FRONT PANEL 1 The screen will display PANEL SWITCH DISABLE command when the ON OFF keypad switch on the front panel is active Press Confirmation Enter Key to disable the keypad switch This is to prevent unauthorized operation of the ON OFF keypad switch CONTROL AHF STOP gt Panel Switch DISABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE The screen will change to PANEL SWITCH ENABLE command when the ON OFF keypad switch on the front panel is inhibited CONTROL AHF STOP gt Panel Switch ENABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 16 User Manual for ARTECHE LCD Control amp Monitor Panel x y POWER QUALITY TO ENABLE ALARM BUZZER 1 The screen will automatically display BUZZER ENABLE command when the buzzer is inhibited Press Confirmation Enter Key to enable the buzzer CONTROL AHF STOP Panel Switch DISABLE gt Buzzer Enable Date amp Time LCD Contrast Password Release Demo ENABLE 2 The screen will change to BUZZER DISABLE command when the buzzer is active CONTROL AHF STOP Panel Switch DISABLE gt Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 17 User Manual for ARTECHE LCD Control amp Monitor Panel x y POWER QUALITY TO DISABLE ALARM BUZZER 1 The scre
9. TE Information Meter gt Control 2 The system will ask for password before displaying the CONTROL menu screen To enter the password use the Up or Down key to select from 0 9 for each digit and the Left or Right key to move from the 1 digit to the 4 digit Use the Confirmation Enter key to confirm the selected password The default password is 0000 Password ENTER PASSWORD 0 3 Once password is confirmed by the system the CONTROL menu screen will be displayed X and select the desired function using the Up or Down Key and Confirmation Enter AHF Stop Panel Switch ENABLE Buzzer Disable Date amp Time LCD Contrast Password Release gt Demo ENABLE 12 P m User Manual for A ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO ENABLE FILTERING OF THE SINE 1 The screen will display RUN command when the system is not providing filtering Follow the start up procedures as described in section 2 and press Confirmation Enter Key to energize the AHF CONTROL gt AHF RUN Panel Switch DISABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 2 Once the AHF is turn on successfully the screen will change to STOP and the Filtering Green LED indicator will light up CONTROL gt AHF STOP Panel Switch DISABLE Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 13 POWER
10. e 2008 08 10 Running gt gt gt gt Time 08 30 00 LoAD RATE Information Meter gt Control Note The current Date amp Time will be lost and reset to the initial conditions 2000 00 00 00 00 00 when AHF is disconnected from utility power for 168 hours 7 days Stored parameters including Events Log Identification Configuration etc will not be affected by this loss of power 20 POWER QUALITY Pa User Manual for A ARTECHE LCD Control amp Monitor Panel TO ADJUST THE LCD SCREEN CONTRAST 1 In the CONTROL menu screen scroll to LCD CONTRAST select by pressing the Confirmation Enter Key CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable Date amp Time gt LCD Contrast Password Release Demo ENABLE 2 In the LCD CONTRAST screen use the Left Right key to adjust the desire contrast LCD CONTRAST Note If the contrast is set too dark the display may not be visible for easy reading 21 User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO CHANGE THE DISPLAY CONTROL PASSWORD 1 In the CONTROL menu screen scroll to PASSWORD RELEASE select by pressing the Confirmation Enter Key CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable Date amp Time LCD Contrast gt Password Release Demo ENABLE 2 In the EXIST PASSWORD field enter the existing or default password using the Directional Scrolling K
11. en will automatically display BUZZER DISABLE command when the buzzer is active Press Confirmation Enter Key to disable the buzzer CONTROL AHF STOP Panel Switch DISABLE gt Buzzer Disable Date amp Time LCD Contrast Password Release Demo ENABLE 2 The screen will automatically change to BUZZER ENABLE command when the buzzer is inhibited CONTROL AHF STOP Panel Switch DISABLE gt Buzzer Enable Date amp Time LCD Contrast Password Release Demo ENABLE 18 Pn User Manual for A ARTECHE LCD Control amp Monitor Panel DATE amp TIME SETTING In the CONTROL menu screen scroll to DATE amp TIME SET select by pressing the Confirmation Enter Key CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable gt Date amp Time LCD Contrast Password Release Demo ENABLE 2 In the DATE amp TIME SET screen use the Up or Down key to select the desire field The selected field will blink continually Use the Left or Right key to enter the desire date amp time DATE amp TIME DATE YYYY MM DD 2004 07 02 TIME HH MM SS 08 30 00 DATE amp TIME DATE YYYY MM DD 2004 07 02 TIME HH MM SS 08 30 00 19 POWER QUALITY User Manual for A ARTECHE LCD Control amp Monitor Panel Use the Confirmation Enter Key to save the final setting data The current set date amp time should appear on the main menu screen Dat
12. eys and confirm the entry by pressing the Confirmation Enter Key PASSWORD RELEASE EXIST PASSWORD 0 NEW PASSWORD PASSWORD CHECK 3 Next enter the new desire password the NEW PASSWORD field as per above PASSWORD RELEASE EXIST PASSWORD ER NEW PASSWORD 0 PASSWORD CHECK 22 User Manual for CN ARTECHE LCD Control amp Monitor Panel Y Y POWER QUALITY 4 Re enter the new desire password in the PASSWORD CHECK field to confirm the new password PASSWORD RELEASE EXIST PASSWORD NEW PASSWORD PASSWORD CHECK 0 23 User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO ENABLE THE DEMO PROGRAM 3 The system contains a demo program to display the various functions of the control panel The factory default of this demo program is disable When you need to enable this program go to DEMO ENABLE command in the CONTROL menu screen and press the Confirmation Enter Key CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable Date amp Time LCD Contrast Password Release gt Demo ENABLE The screen will change to DEMO DISABLE command when the demo program is active The DEMO command will appear on the main menu screen CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable Date amp Time LCD Contrast Password Release gt Demo DISABLE Scroll to DEMO and press the Conf
13. irmation Enter Key the screen will start to continuously display the various functions of the control panel Press the Escape Key to stop Date 2008 08 10 Running gt gt gt gt Time 08 30 00 Loap RATE Information Meter Control gt DEMO 24 WESS User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO DISABLE THE DEMO PROGRAM The screen will automatically display DEMO DISABLE command when the demo program is enabled Press Confirmation Enter Key to disable the demo program CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable Date amp Time LCD Contrast Password Release gt Demo DISABLE 2 The screen will automatically change to DEMO ENABLE command when the demo program function is cancelled The DEMO command will disappear from the main menu screen CONTROL AHF STOP Panel Switch DISABLE Buzzer Enable Date amp Time LCD Contrast Password Release gt Demo ENABLE Date 2008 08 10 Running gt gt gt gt Time 08 30 00 Loap RATE Information Meter Control 29 User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY INFORMATION MENU TO DISPLAY SINE SYSTEM INFORMATION 1 Scroll to INFORMATION select by pressing the Conformation Enter key Date 2008 08 10 Running gt gt gt gt Time 08 30 00 LoAD RATE gt Information Meter Control 2 In the INFORMATION menu screen scroll to
14. lect the desire waveform parameters you wish to view You can choose up to 2 parameters for viewing The waveforms will be displayed on WAVEFORM WINDOW 1 amp WAVEFORM WINDOW 2 respectively 3 Waveform Vab la L gt la S la E Vbc Ib L Ib S Ib E Ic L Ic S Ic E Waveform Window 1 la S Waveform Window 2 la L User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY 4 Once you have selected the desire parameters go to VIEW on the right of the screen and press the Confirmation Enter Key The Waveforms will be displayed in the next screen Waveform Vab E ETC Eia Vbc Ib L Ib S Ib E Ic L 1 5 Ic E gt View Waveform Window 1 la S Waveform Window 2 la L 5 View desired waveforms in windows 1 and 2 WAVEFORM_VIEW WINDOW 1 la S WINDOW 2 la L Vab Line voltage waveform between A amp B phase la L A phase current waveform at Load side la S A phase current waveform at Source side la E A phase current waveform at Sine side User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO VIEW THE HARMONICS SPECTRUM 1 Use the Up or Down key to scroll to METER select by pressing the Confirmation Enter Key Date 2008 08 10 Running gt gt gt gt Time 10 15 00 Loap RATE Information gt Meter Control 2 Once inside the METER menu scroll to SPECTRUM
15. ntrol information On Off Keypad Reset Alarm Silence Keypad Power On Indicator Filtering Indicator Full Correcting Indicator Error Indicator Confirmation Enter Key Directional Scrolling Key 0 Escape Cancel Key ee ee User Manual for CN ARTECHE LCD Control amp Monitor Panel Y Y POWER QUALITY OPERATING THE GRAPHIC LCD MONITOR FUNCTIONAL DESCRIPTIONS The LCD Monitor provides the user a Man Machine interface with the AHF for operational control monitoring and AHF information The Graphical Display has the following advantages Provides automatic measurements 4 readings of various parameters alarm indications and status allowing user to diagnose the AHF operating conditions more efficiently Provides voltage amp current waveform display Provides harmonics measurement amp spectrum display Display operating amp control procedures and information of major components User friendly reduce risk of miss operation User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY D FUNCTIONAL FLOW CHART IDENTIFICATION INFORMATION EVENTSLOG PAsswonp EVENTS LOG CLEAR CONFIGURATION LOAD SIDE PARAMETER SOURCE SIDE MAIN METER WAVEFORM AHF SPECTRUM AHF RUN STOP PANEL SWITCH ENABLE DISABLE BUZZER
16. sing the Confirmation Enter Key gt Parameter Waveform Spectrum 3 To view readings for the Load Side the Source Side or the AHF scroll to the desired directory using the Directional Scrolling Key Pads and select using the Confirmation Enter Key All of the various parameter readings will be displayed PARAMETER gt LOAD SIDE SOURCE SIDE AHF POWER QUALITY ARTECHE 4 Read Load Side measurements LOAD SIDE KVA 32 6 Freq 60Hz Vab 480V Vbc 480V THD 0 2 THD 0 2 la 52 2A Ib 51 9A THD 18 4 THD 19 1 User Manual for LCD Control amp Monitor Panel PF 0 87 Bca 480V THD 0 2 Ic 52 1A THD 18 7 KVA Apparent Power Vab Line Voltage between A amp B Phase Freg Operating Frequency Hz THD Total Harmonic Distortion in percentage PP Power Factor la A phase current User Manual for ARTECHE LCD Control amp Monitor Panel POWER QUALITY TO VIEW THE ELECTRICAL WAVEFORM Use the Up or Down key to scroll to METER select by pressing the Confirmation Enter Key 1 Date 2008 08 10 Running gt gt gt gt Time 10 15 00 LoAD RATE Information gt Meter Control 2 Once inside the METER menu scroll to WAVEFORM select by pressing using the Confirmation Enter Key Parameter gt Waveform Spectrum In this menu use the Directional Scrolling Key Pads amp Confirmation Enter Key to se