Home

Varytec F-3000 DMX

image

Contents

1. a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt If out of work contact sales agency immediately Any troubles arose remove the power plug soon and contact with an engineer for repairing do not open the cabinet by yourself it might result a danger of electric shock Take care with the power cable Never pull the power cable to remove the plug from the receptacle be sure to hold the plug When not using the device for an extended period of time be sure to disconnect the plug from the receptacle 3 9 VARYTEC el Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems Make sure the electrical connection is carried out by qualified personnel All electrical and mechanical connections have to be carried out according to the European safety standards 2 Cautions Risk of electric shock Disconnect the appliance from the electric supply before removing the cover Note there are no user serviceable parts inside 2 1 Danger of electric shock Keep this device dry For inside use only Not designed for outside use Y For the 110V models use 3 prong grounded electrical outlet only Prior to use take care to determine that the unit is installed at the rated voltage Always unplug y
2. unplugged and cool unscrew nozzle at very front of unit and clean out debris with vinegar and a pipe cleaner making sure that the hole is free of clogs 2 Empty all fog fluid from machine Add cleaning solution to tank Plug unit in and begin warm up 3 Run unit in a well ventilated area until tank is empty 4 Replace nozzle 5 Cleaning is now complete Refill with fog liquid Note All fog machines are prone to clogging due to the thick consistency of fog fluid and the high temperature at which it vaporizes However a properly maintained fog machine should provide years of reliable use Clean with a dry cloth only Store dry 7 9 VARYTEC 5 1 Performance Notes All fog machines develop condensation around the output nozzle Because this may result in some moisture accumulation on the surface below the output nozzle consider this condensation when installing your unit All fog machines may sputter small amounts of fog occasionally during operation and for a minute or so after being turned off All fog machines have a recycling period after long bursts when the machine will shut itself down for a short period in order to heat back up During this time no fog can be produced The green READY L E D on the remote will be off during this time and will light up again when the machine is ready If the supply cord is damaged it must be replaced by manufacturer or its service agent or similarly qualified person in order t
3. VARYTEC User manual ie X Varytec F 3000 DM oe VARYTEC Table of contents Te Safety INSTUCIONS asus kennelen 1 1 FOR SAFE AND EFFICIENT OPERATION iris 2 CAUSA aia 2 1 Dangeror CleCtric SNOCK aan ness adelen es 2 2 Pangeror BUs Lana ee NG 2 3 Dangeror 6xPlosl0nhuynanesu nn sG 3 Unpacking amp Inspection mia ad eee ee pees O AT 32 Operational did 4 Remote Control Operation isa Se E i kebebe teken ehe er 5 1 Performance Noesen EE 6 Technical Dada ti 2 9 EA VARYTEC 1 Safety instructions e This device is suitable for indoor use only e All modifications to the device will void the warranty e Repairs are to carry out by skilled personnel only e Use only fuses of the same type and original parts as spare parts e Protect the unit from rain and humidity to avoid fire and electric shocks e Make sure to unplug the power supply before opening the housing 1 1 FOR SAFE AND EFFICIENT OPERATION Be careful with heat and extreme temperature Avoid exposing it to direct rays of the sun or near a heating appliance Not put it in a temperature bellow 32F 0 or ex ceeding 104F 40T Keep away from humidity water and dust Do not place the set in a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoid placing on un stable location Select
4. are fogging Running a fog machine with no fluid can permanently damage the unit If you experience low output pump noise or no output at all unplug immediately Check fluid level the external fuse remote connection and power from the wall If all of the above appears to be O K plug the unit in again If fog does not come out after holding the remote button down for 30 seconds check the hose attached to the tank to make sure there is fluid going through the hose If you are unable to determine the cause of the problem do not simply continue pushing the remote button as this may damage the unit Return the machine to your Varytec dealer 4 Remote Control Operation Description of the elements of the Z 2 1 Function key 2 Up Down keys 3 Timer key 4 Volume switch 5 Manual key 1 Via the Function key you can adjust the desired settings After pressing the Function key once the display shows Interval Set Adjust the interval between each fog emission within the range of 1 to 255 seconds by means of the Up Down keys By pressing the Function key twice the display shows Duration Set Adjust the duration of each fog emission within the range of 1 to 20 seconds by means of the Up Down keys Under the menus Timer Out and Volume Out you can adjust the output volume by means of the Up Down keys The menu DMX Add refers to adjusting the DMX address for DMX control or synchronization Adjust the desired DMX address
5. by means of the Up Down keys 6 9 VARYTEC el 2 Press the Timer key to activate the timer function The display shows the adjusted interval and the device counts the seconds down to 0 After that the fog emission is triggered at the volume adjusted under Timer Out The duration depends on the settings adjusted under Duration Set If you wish to deactivate the timer function press the Timer key once more 3 Press the Volume switch for immediate triggering of the fog emission at the volume adjusted under Volume Out Press the Volume switch once more in order to stop the fog emission 4 Press the Manual key for immediate triggering of the fog emission at 100 volume Let the Manual key loose in order to stop the fog emission For control of the DMX settings please refer to the section on Page 6 titled Varytec F Series Onboard DMX Fog Machine Settings Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges 5 Maintenance Do not allow the fog liquid to become contaminated Always replace the caps on the fog liquid container and the fog machine liquid tank immediately after filling After every 40 hours of continuous operation it is recommended to run a cleaning solution composed of 80 distilled water 20 white vinegar through the system to prevent the accumulation of particulate matter in the heating element The recommended cleaning regimen is as follows 1 While unit is
6. o avoid a hazard Please read and save these instructions Note In the example above if the machine were assigned the DMX address of 124 Channel A would correspond to DMX address 124 In general Varytec fog machines with onboard DMX conform to the following performance specifications 1 Average Operating temperature 250 C 2 Fogger can maintain maximum output for 30 seconds or more 3 Fogger can maintain constant output at 30 volume setting roughly a value of 75 6 Technical Data Voltage AC 100 240V 50 60Hz Heating Power 3000 Watt Output 1100 m Tank volume 6 Liter consumption 14 min Liter Warming up time 11 Min Holding bracket no DMX yes Controller inklusive Measures LxHxW 665 x 207 x 303 mm weight 21 0 kg 8 9 VARYTEC Importer B amp K Braun GmbH Industriestra e 1 D 76307 Karlsbad www bkbraun com info bkbraun com C H Bons 2002 95 EC
7. our Varytec Fog Machine before filling its tank Keep fog machine upright Turn off or unplug when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the housing immediately unplug the unit and contact a service technician or your Varytec dealer before using it again No user serviceable parts inside Refer to your Varytec dealer or other qualified service personnel 2 2 Danger of burns For adult use only Fog machine must be installed out of the reach of children Never leave the unit running unattended Never aim the output nozzle directly at people Fog machine output is very hot Avoid coming within 60 cm of the output nozzle during operation Y Locate the fog machine in a well ventilated area Never cover the unit s vents In order to guarantee adequate ventilation allow a free air space of at least 20 cm around the sides and top of the unit Never aim the output nozzle at open flames 4 If the supply cord is damaged it must be replaced by manufacturer or its service agent or similarly qualified person in order to avoid a hazard 4 9 VARYTEC el The output nozzle becomes very hot during operation 3000 Keep flammable materials at least 50 cm away from the nozzle Always allow your Varytec Fog Machine to cool down before attempting to clean or service it 2 3 Danger of explosion Never add flammable liquids of any kind oil gas pe
8. r Varytec dealer for assistance 3 1 Setup Remove all packing materials from shipping box Check that all foam and plastic padding is removed especially in the nozzle area Place fog machine on a flat surface and remove fog liquid tank cap 4 Fill with Varytec Fog Liquid or other high quality water based fog fluid Any other types of fluid can damage the unit When filled place cap back on liquid tank Firmly attach the remote control cable to the proper input on the rear of the machine 5 9 VARYTEC 3 2 Operation Plug power cord into a grounded electrical outlet If necessary turn power switch on rear of unit to ON position Warm up is complete when green lamp lights up on remote unit To emit fog press the appropriate button on the remote for the desired length of time The remote unit s lamp will cycle on and off as the machine re heats to the proper operating temperature 9 For further information on operating your Varytec Fog Machine see the section titled Remote Control Operation If your model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important that the fog does not shoot directly at any one s face Whatever installation method you choose do not allow the unit to have more than a 15 degree angle of inclination Important Always monitor tank fluid level as you
9. rfume to the fog liquid Pay attention to all warning labels and instructions printed on the exterior of your Varytec Fog Machine Use only the high quality water based fog liquid that your dealer recommends Other fog liquids may cause clogging or spitting Always make sure there is sufficient liquid in the fog liquid tank Operating this unit without liquid will cause damage to the pump as well as over heating of the heater 9 If your Varytec Fog Machine fails to work properly discontinue use immediately Drain all fog liquid from the tank pack the unit securely preferably in the original packing material and return it to your Varytec dealer for service Always drain tank before mailing or transporting this unit Never drink fog liquid If it is ingested call a doctor immediately If fog liquid comes in contact with skin or eyes rinse thoroughly with water 3 Unpacking amp Inspection Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact Refer to the Features section for information on what items are included with your model lf any equipment is missing contact your Varytec dealer immediately Before beginning initial setup of your Varytec Fog Machine make sure that there is no evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting you

Download Pdf Manuals

image

Related Search

Related Contents

Journal n° 02  Parkinson Cowan Libra User's Manual  Quadra-Fire HUDBAY-INS 7008-115 User's Manual  Accessori pompe a pistone  Ents Booking User Guide 2011-II  取扱説明書 - amadana  Chronic Pelvic Pain - Chester County Ob/Gyn Associates  Communiqué de presse WIKEEPS Octobre 2014 (2)  User Guide and Assembly Instructions Agriled® armature IP64  